Preview only show first 10 pages with watermark. For full document please download

Channel Alarm Module (cam)

   EMBED


Share

Transcript

Channel Alarm Module (CAM) Channel Alarm Module, programmable ten (10) channel alarm monitor configurable via APM. Optional for Advanced Power Monitor (APM) product range CAM0000 The Channel Alarm Module (CAM) is an optional module that may be used with the Antenna System Monitor (ASM) to allocate a dedicated alarm output for up to any ten (10) channels being monitored by the ASM. Additional CAM’s can be easily added (daisy-chained) to increase the number of monitored channels with dedicated alarm outputs. The respective ASM will auto-detect the CAM module when connected and through the GUI (Graphical User Interface) of the ASM. The user can configure which of the CAM outputs are assigned to respective ASM monitored channels. Conditional alarm status is a feature that allows the individual base station PTT lines to be compared with the ASM channel alarm status, allowing a “no RF output” from the base station to be recognised and inhibit an alarm. Four (4) additional “general purpose” digital alarm inputs are available on each CAM to monitor site alarms - such as site access doors, battery threshold levels and site conditions. Front and rear LED’s provide a visual indication of the status of all 10 output and 4 input alarms. Features n User assigned 10-Ch alarm relay module n Auto detected by APM n Conditional n Compact PTT status alarm reporting 1RU 19” rack mountable shelf. n Expandable n Enabling n Up using up to a total of 8 additonal CAM’s each monitoring up to 10 Channels. priority alarm reporting, providing a tigger as a Hot/Standby base station radio switch to 4 user configurable, general purpose logic alarm inputs n Power daisy chained from APM power input n Communications n Front interface daisy-chained between APM and respective CAM’s and rear alarm relay activation notification LED’s FRONT VIEW REAR VIEW Specification Model Number CAM0000 Alarm outputs 10 Alarm contact type Dry Relay N.O. / Common / N.C. Alarm contact rating - max 50VDC 1A 10 (configurable - one per alarm output) Alarm inputs 4 (configurable - general purpose) “0” = <2.5VDC Alarm input logic “1” = > 2.5VDC Visual alarm notficiation Front and Rear panel mounted LED’s Power Supply options (APM - daisy chained) 9-36VDC or 36-60VDC Connectors Note: All connectors on rear External Alarm inputs: 1 x Polarised 8-pin Phoenix connector Channel Alarm Outputs: 10 x Polarised 3-pin Phoenix connector Channel Alarm Inputs: 10 x Polarised 2-pin Phoenix connector Power Supply: 1 x Polarised 2-pin Phoenix connector Comms Inteface to/from APM: Mounting 1 X DB15 (M) 1RU 19” Rack mounting Dimensions W 483 x H 45 X D 77mm / W 19 x H 1.75 x D 3” Weight <1kg / < 2.2lbs Operational temperature range -30 °C to + 60° C / -22°F to 140°F Ordering Information Model Number Description CAM0000 Channel Alarm Module, PTT activated 10 Channel, 4 Ext Alarm Inputs, 9-36VDC. CAM0000-48 Channel Alarm Module, PTT activated 10 Channel, 4 Ext Alarm Inputs, 36-60VDC P-41589-1 Copyright RF Industries Pty Ltd 2013. Subject to change without notice. 1 rfiwireless.com.au Channel Alarm Module (CAM) CAM0000 Optional for Antenna System Monitor (ASM) product range CAM0000 APPLICATION DIAGRAM P-41589-1 Copyright RF Industries Pty Ltd 2013. Subject to change without notice. 2 rfiwireless.com.au