Transcript
CHH8 - Ceiling Hinge Heavy Mechanism
Technical Sheet
ISSUE 001 SHEET 1 of 5 FUNCTION
UP DESIGN HIGHLIGHTS •
Near silent motor system
•
Modular format ensures simple installation
•
Range of standard sizes
•
Sized to suit options available
DOWN
The CHH mechanism hinges a flat screen television from a ceiling through 90 degrees. (100 degrees is possible on some models).
SUITABILITY This CHH8 can take a screen up to a 1920mm [75.6"] wide by 1250mm [49.2"] high by 150mm [5.9"] deep. Maximum weight of 100Kg [220lbs]
OPTIONS •
Swivel version with the CHHS6,7, 8 and 9
•
Telescope option with the lighter weight CHT 4, 5 and 6
•
Marine suitable option with IP rated outdoor mechanisms with the M-CH3,4,5 and 6
•
Any RAL colour available
•
Bang & Olufsen / Loewe mount option
CONTROL Supplied with basic infrared remote. Can be learnt by many learning remotes. Also has contact closure and RS232 so can be operated by switches, Crestron, AMX or Lutron systems Installation framework to simplify integration.
Screen signal cables exit here.
Modular installation system for easy install.
WARNING
IMPORTANT
It is the responsibility of the installer to warn all potential end users of the dangers of interfering with mechanisms during operation
Mechanisms which lift or move weights need to be checked on a yearly basis for any damage which may result in an accident
www.futureautomation.co.uk
tel: +44 (0) 1438 833 577
Custom made screen surround is supplied.
fax: +44 (0) 1438 833 565
CHH8 - Ceiling Hinge Heavy Mechanism Fitting Notes
The Future Automation Ceiling Hinge has some great features to make installation as simple and quick as possible.
ISSUE 001 SHEET 2 of 5
Technical Sheet
Stage 1
Stage 2
The installation frame is initially fixed in place. Suspend from studding or fix corner plates direct to timber beams.
The mechanism gearboxes and two cross braces can be fixed into position. Fine height adjustment is located in each corner.
Prior to installation the plasterboard/gyproc can be in place as all mechanism parts will fit through the opening. (Or the ceiling can be installed at a later stage.)
These side rails can be discarded if the corner plates are to be fixed to timber beams
Height adjust bolts Hanging brackets Gearbox
Cross brace
Finished plasterboard/gyproc ceiling
Corner plates
Stage 3
Cross brace
Signal cables can be run before the top panels and edge panels are fixed in place.
All screen signal and power cables enter here
Stage 4 Finally add main frame, screen panel, screen and screen surround. Edge panels
www.futureautomation.co.uk
Top panels added from below
tel: +44 (0) 1438 833 577
fax: +44 (0) 1438 833 565
CHH8 - Ceiling Hinge Heavy Mechanism Plan View
Side Section BB
Technical Sheet 72.3 1835
B
49.2 1250 MAXIMUM SCREEN HEIGHT
A
ISSUE 001 SHEET 3 of 5
SECTION B-B SCALE 1 : 8
A
Viewing Side
B
4.7 119
62.4 1585 Cut-out in Plasterboard\Gyproc
5.2 131
Front View Section AA SECTION A-A SCALE 1 : 8
19mm [0.7"] Maximum Ceiling Panel Thickness
Allow a further 25mm [1"] above this height 75.6 1920 MAXIMUM SCREEN WIDTH
12.2 311
Ceiling Panel 8.3 212
80.6 2047 Cut out in Plasterboard\Gyproc
See CAD drawings for more dimensional information
www.futureautomation.co.uk
tel: +44 (0) 1438 833 577
fax: +44 (0) 1438 833 565
8.4 213
CHH8 - Ceiling Hinge Heavy Mechanism
ISSUE 001 SHEET 4 of 5
Technical Sheet
FRONT FACE Some clearance is useful above for getting more clearance to the height adjust bolts. (25mm [1"]) 95.0 2412
12.2 311 0.0 0
PLAN VIEW
4.0 101
Detail of hanging bracket.
7.9 201
Screen and signal cables exit here on the right side of the mechanism.
64.3 1634
0.6 16
68.3 1734
Viewing Side
72.3 1835
0.0 0
5.2 133
11.5 293
Fixing Suitable for hanging mechanism
SCALE 1:15 97.3 2472
www.futureautomation.co.uk
tel: +44 (0) 1438 833 577
fax: +44 (0) 1438 833 565
See CAD drawings for more dimensional information
CHH8 - Ceiling Hinge Heavy Mechanism
ISSUE 001 SHEET 5 of 5
Technical Sheet
Side Section in Down Position
View Up Without Ceiling Panels
63.6 1614
A
DETAIL A SCALE 1 : 5
2.3 58 Flange detail This dimension will increase as the screen size is reduced from the maximum allowed.
82.0 2082 SCALE 1:35 1.2 30
Front View in Down Position
It requires a 5 amps at 110v/240vAC supply. Infrared RS232 and contact closure inputs need to be made to this box.
SCALE 1:20
www.futureautomation.co.uk
79.0 2006
tel: +44 (0) 1438 833 577
fax: +44 (0) 1438 833 565
0.0 0
A control box 220 x 55 x 150mm [8.7" x 2.2" x 6.0"] needs to placed in an accessible location. It is supplied on a 5 metre [16ft] flying lead. A DC power supply 250 x 150 x 55 [10.0 x 6.0 x 2.2] will also be supplied to go in the same area. One possible place to put the box is behind a ceiling speaker. 7.6 192 5.2 131
53.9 1369
Screen cable exit