Transcript
Chloride CP-70Z 31 UL AC UPS System 2.5 to 250kVA – 1ph output
Industrial Power for Business-Critical Continuity™
Chloride CP-70Z industrial Uninterruptible Power Supply (UPS) system is the flagship product of Chloride Industrial Power. It combines conservative design topology with proven digital control technology to offer the best performances in any electrical and environmental condition.
Custom-designed AC UPS systems to secure critical industrial processes.
The Chloride CP range is designed to meet the stringent electrical and mechanical requirements in industrial environments. Each Chloride CP product is based on interchangeable sub-assemblies to allow full customization, in compliance with client’s technical specification and with project documentation requirements.
The CP-70Z 31 is a range of three-phase input / single-phase output AC UPS systems available from 2.5kVA to 120kVA. It offers a wide choice of DC battery voltages and of output voltages.
Benefits Tailor made systems to comply with all customer’s specifications Ruggedized solutions for demanding environments: high temperatures, vibrations, dust, elevation, dripping water and moisture Efficient maintenance thanks to easy front access to all critical modules of the system
Key Features Reliability - Unique design which allows the UPS to continuously operate for at least 20 years at full load at 104°F (40°C) Robust mechanical design - The system withstands vertical and horizontal acceleration stress tests up to 0.5g as standard Galvanic isolation - Input and output transformers are included as standard Multilingual digital graphic display with embedded event log Remote monitoring capabilities: Modbus, Profibus, DF1, Ethernet, volt-free contacts, monitoring software Fully customized electrical and mechanical solutions – On demand design to comply with every standard (e.g. UL, ANSI, NEMA, IEC, CSA, ABS, DNV) Full compatibility with Lead-acid and Nickel-Cadmium batteries, valve regulated or flooded
Applications The Chloride CP-70Z AC UPS system protects heavy-duty applications of the following industries: Oil & Gas offshore and onshore Refining and petrochemical Conventional power generation Transportation (rail, metro, tramway)
Associated with an industrial stand-by battery, the Chloride CP-70Z 31 protects critical industrial AC equipments and processes from the damaging effects of power interruption and losses. It uses the patented digital Vector Control technology which increases the performances of power components and enables an active conditioning of the load. The result is improved reliability for the process and enhanced safety for the personnel.
The CP-70Z 31 range can be customized to meet higher power needs, up to 250kVA single-phase output. To further improve load availability and process reliability, the CP-70Z 31 is able to operate in dual parallel configuration, with single or dual batteries, with centralized or distributed reserve line, and can include a DC and/or AC bus-tie.
Chloride CP-70Z 31 UL AC UPS System
Ratings - Output Power at cos phi 0.8 (kVA) vs DC intermediate voltage (Vdc) 110-120Vdc 2.5 5 7.5 10 15 20 25 30 40 50 60 -
220-240 Vdc 10 15 20 25 30 40 50 60 80 100 120 Up to 250 kVA on request
400 Vdc 40 50 60 80 100 120
Battery
Reserve
System
Mechanical
Communication
Input Input voltage (other voltage on request) Voltage tolerance Frequency
60 Hz (50 Hz)
Frequency tolerance
±5%
Intermediate DC circuit Nominal DC voltage
110 - 120 / 220 - 240 / 400 Vdc
Voltage stability
±1% in float mode, input within tolerance ±1.5% for parallel rectifiers
Voltage ripple (battery connected)
1% RMS in float, with battery connected
Output Available ratings
see table on the left 1 x 120 (110) 1 x 240 (220)
Frequency Specified three-phase input voltage (from 3 x 208 to 3x600Vac) 12 pulse rectifier Harmonic filter Ripple filter Blocking diode Inrush current limitation to 8In Surge and lightning protections Battery circuit protection box Battery cabinet or rack Low-voltage disconnect contactor Battery Management System Battery room temperature sensor By-pass transformer By-pass stabilizer By-pass harmonic filters Extended operating temperature range up to 122°F (50°C) Dual parallel configurations Hot stand-by configuration Specified input / intermediate / output isolators DC/DC serial regulator isolated DC/DC converter AC distribution Earth fault monitoring Backfeed protection Internal lighting Anti-condensation heater Tenmerature monitor Special cabinet identification NEMA 1, 1x, 2 Top or bottom cable entry Other frame color Anti-seismic design Front-panel analog meters Transducers Additional volt-free contacts industrial protocols (Modbus, Profibus, DF1, etc...) Passive or active mimic panel Monitoring software PPVis
Non-exhaustive list of options. Consult us for any other requirement.
60 Hz (50 Hz)
Frequency stability (free running)
±0.05%
Frequency tracking range
±4% (from 1.2 to 6% adjustable)
Voltage stability (0-100% load variation): • static (balanced load) • dynamic
+/-1% (±2% for parallel inverters) +/-5%
Overload inverter: • 10 min • 1 min
150% of nominal power 125% of nominal power
Short-circuit clearance: • 100 ms •5s
250% of nominal current 175% of nominal current
Harmonic voltage distortion: • with 100% linear load • with 100% non linear load - CF 3:1
<3% ≤5%
Allowable power factor
0.5 lagging to 0.5 leading
Allowable crest factor
3:1
Battery Type
Lead Acid or Nickel Cadmium, valve regulated or flooded
Autonomy
As per customer’s requirement
Recommended float / charge voltage per cell
2.25V (Lead-Acid battery) 1.4-1.45V (Nickel-Cadmium battery)
Recommended boost voltage per cell
2.33V (Lead-Acid battery) 1.45-1.52V (Nickel-Cadmium battery)
General Data Efficiency
up to 90% at full load, according to rating
Operating temperature
32 to 104°F (0 to 40°C) up to 122°F (50°C) on request
Storage temperature
-4 to 158°F (-20 to +70°C) (battery excluded)
Relative humidity
<90 % non condensing at 68°F (20 °C)
Operating altitude
0 to 3,200 ft (1,000 m ) above sea level, without system derating
Cooling
Forced
External protection
Standards Compliance
UL1778, IEEE, NEC
Conformity
UL Label
Emerson Network Power. The global leader in enabling Business-Critical Continuity™. Emerson Network Power 11100 Brittmoore Park Drive - Houston - TX77041 - USA T: +1 713 827 4309
[email protected] EmersonNetworkPower.com
3 x 480V ±10% without discharging batteries
AC voltage: • Single phase
Options Rectifier
Technical Data
NEMA 1 according to IEEE-250
Noise
70-75dB at 6 ft (depending on rating)
Frame colour
Gray ANSI-61
Dimensions
Varying according to ratings and options
AC Power
Embedded Power
Power Switching & Controls
Connectivity
Industrial Power
Precision Cooling
DC Power
Infrastructure Management & Monitoring
Racks & Integrated Cabinets
Embedded Computing
Outside Plant
Services
While every precaution has been taken to ensure the accuracy and completeness of this literature, Emerson Network Power assumes no responsability and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
Industrial Power for Business-Critical Continuity™
2.5 to 250 kVA - 1 ph output
Emerson, Business-Critical Continuity and Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. ©2013 Emerson Electric Co. CP70Z 31 UL AC UPS System-DSUS-Rev0-09/2013