Preview only show first 10 pages with watermark. For full document please download

Chp Max™ Digital Return Path Receivers Chp D2rrx

   EMBED


Share

Transcript

CHP Max™ Headend Optics Platform Digital Return Path Receivers CHP D2RRX – dual optical inputs Specications CHP-D2RRX-65 CHP-D2RRX-42 CHP-D2RRX-85 Input Wavelength Range 1200 to 1620 nm 1200 to 1620 nm 1200 to 1620 nm Optical Power Input Range PIN: CHP-D2RRX-XX-MD PIN: CHP-D2RRX-XX-MQ APD: CHP-D2RRX-XX-XD APD: CHP-D2RRX-XX-XQ –18 to –18 to –27 to –27 to –22 to –22 to –31 to –31 to Optical Connector SC/APC (8 degrees) SC/APC (8 degrees) SC/APC (8 degrees) Optical Return Loss 55 dB 55 dB 55 dB RF Output Bandpass 5 to 65 MHz 5 to 42 MHz 5 to 85 MHz Output and Testpoint Impedance 75Ω 75Ω 75Ω Output Level, max., OM4100/OM3100 44/42 dBmV 44/42 dBmV 41/39 dBmV Gain Stability over Temperature ± 0.5 dB ± 0.5 dB ± 0.5 dB Quantizing Noise and Spurs (below 500MHz) –50 dBc –50 dBc –50 dBc Flatness ±0.50 dB ±0.50 dB ±0.50 dB Output and Testpoint Return Loss, min. 16 dB 16 dB 16 dB RF Testpoint –20 dB ± 0.5 dB –20 dB ± 0.5 dB –20 dB ± 0.5 dB Redundancy Switching Time <50 ms <50 ms Not applicable Programmable RF Attenuator Range 0 to 30.0 dB in 1.0 dB steps 0 to 30.0 dB in 1.0 dB steps 0 to 30.0 dB in 1.0 dB steps Programmable RF Attenuator Resolution 1.0 dB per step 1.0 dB per step 1.0 dB per step Programmable RF Attenuator Accuracy ±0.20 dB ±0.20 dB ±0.20 dB 50/48 dB 50/48 dB 50/48 dB Dynamic Range, typical @ 40 NPR, typical/ 16/15 dB min. 16.5/15 dB 16/15 dB BER Dynamic Range, @ 10–6 BER 28 dB (64–QAM), 34 dB (16-QAM), 45 dB (QPSK) 26 dB (64–QAM), 32 dB (16-QAM), 43 dB (QPSK) RF Link Gain, 0dB input attenuation at Tx, 32 /30 dB max. gain at Rx, OM4100/OM3100 32 /30 dB 29/27 dB Link Flatness, typical/min. ±0.75 dB/±1.0 dB ±0.75 dB/±1.0 dB ±0.75 dB/±1.0 dB 13.0/16.0 W 13.0/16.0 W 10.0/13.0 W Optical 0 dBm (see Note 1) 0 dBm (see Note 1) –10 dBm (see Note 2) –10 dBm (see Note 2) 0 dBm (see Note 1) –22 to 0 dBm (see Note 1) 0 dBm (see Note 1) –10 dBm (see Notes 2,3) –29 to –10 dBm (see Note 2) –10 dBm (see Notes 2,3) RF Redundancy and Attenuator Performance Noise-Power Ratio (NPR), typical/min. 26 dB (64–QAM), 32 dB (16-QAM), 43 dB (QPSK) Power Power Consumption (typical/max.) Notes: 1.  Tested with 60 km ber, DWDM SFP in a transmitter. 2.  Tested with 100 km ber, DWDM SFP in a transmitter. 3.  Typical reported optical input power monitor accuracy is ±1 dB at optical input levels >-31dBm and ±2 dB at optical input levels <-32dBm. Optical power measurements are calibrated in the 1550-nm region. Technical Specication CHP D2RRX Digital Path Return Receivers Technical Specication Specications CHP-D2RRX-65 CHP-D2RRX-42 CHP-D2RRX-85 Dimensions (W x H x D) 3.18 x 8.74 x 46.99 cm (1.25 x 3.44 x 18.5 in) 3.18 x 8.74 x 46.99 cm (1.25 x 3.44 x 18.5 in) 3.18 x 8.74 x 46.99 cm (1.25 x 3.44 x 18.5 in) Weight 1.35 kg (3.0 lbs) 1.35 kg (3.0 lbs) 1.35 kg (3.0 lbs) Operational Ambient Temperature Range, °C (°F) 0 to 50(32 to 122) 0 to 50(32 to 122) 0 to 50(32 to 122) Storage Temperature Range, °C (°F) -40 to 85 (-40 to 185) -40 to 85 (-40 to 185) -40 to 85 (-40 to 185) Operating Altitude (Above Mean Sea Level), m (ft) –60 to 4,000 (–197 to 13,123 –60 to 4,000 (–197 to 13,123 –60 to 4,000 (–197 to 13,123 Operating Relative Humidity, non-condensing 5 to 95% 5 to 95% 5 to 95% Mechanical Environmental Ordering Information To congure a product that meets your specic needs, or for any questions, please contact your ARRIS Sales Professional. You may also use our Product Wizard, located at support.arrisi.com (User ID and password required). If you do not have a user ID and password or have forgotten your password, please use the Sign In Help section indicated. Specications are subject to change without notice. The capabilities, system requirements and/or compatibility with third-party products described herein are subject to change without notice. ARRIS, the ARRIS logo, Auspice®, BigBand Networks®, BigBand Networks and Design®, BME®, BME 50®, BMR®, BMR100®, BMR1200®, C3™, C4®, C4c™, C-COR®, CHP Max5000®, ConvergeMedia™, Cornerstone®, CORWave™, CXM™, D5®, Digicon®, E6000™, ENCORE®, EventAssure™, Flex Max®, FTTMax™, HEMi®, MONARCH®, MOXI®, n5®, nABLE®, nVision®, OpsLogic®, OpsLogic® Service Visibility Portal™, Opti Max™, PLEXiS®, PowerSense™, QUARTET®, Rateshaping®, Regal®, ServAssure™, Service Visibility Portal™, TeleWire Supply®, TLX®, Touchstone®, Trans Max™, VIPr™, VSM™, and WorkAssure™ are all trademarks of ARRIS Group, Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and the names of their products. ARRIS disclaims proprietary interest in the marks and names of others. © Copyright 2013 ARRIS Group, Inc. All rights reserved. Reproduction in any manner whatsoever without the express written permission of ARRIS Group, Inc. is strictly forbidden. For more information, contact ARRIS. CHP_D2RRX_TS_20MAR13 www.arrisi.com