Transcript
CHXESP CHXESP + W INSTRUCTION MANUAL
Via Rostoncello, 1 – 36010 Carrè – Italy Tel. +39-0445-36 www.teknosystem.eu
[email protected]
CHXESP – CHXESP+W – HOUSING KIT
INSTRUCTION MANUAL
SECURITY...........................................................................................................................3 1.1 1.2
SYMBOLS ............................................................................................................................................................ 3 GENERAL INFORMATION ..................................................................................................................................... 3
2
DESCRIPTION ..............................................................................................................4
3
CONTENTS OF THE BOX ............................................................................................4 3.1 3.2 3.3
4
OPENING THE BOX........................................................................................................................................ 4 CONTENTS OF THE BOX.............................................................................................................................. 4 EQUIPMENT NEEDED ................................................................................................................................... 4
ASSEMBLY...................................................................................................................5 4.1 WALL MOUNTING........................................................................................................................................... 5 4.2 POLE MOUNTING ........................................................................................................................................... 5 4.3 SEPARATING/JOINING THE BRACKET ..................................................................................................... 6 4.3.1 OPENIG THE HOUSING ........................................................................................................................ 6 4.3.1.1 4.3.1.2 4.3.1.3 4.3.1.4
CHOOSING THE RIGHT BRACKET POSITION ..............................................................................................7 CHANGE THE CONFIGURATION OF THE BRACKET...................................................................................8 CABLES ENTRY ....................................................................................................................................................9 FIXING THE HOUSING FRAME TO THE BRACKET ....................................................................................10
4.3.2 INSTALLING THE VIDEO CAMERA .................................................................................................. 11 4.4 ELECTRICAL CONNECTIONS ................................................................................................................... 12 4.4.1 CABLING INSTRUCTIONS FOR ELECTRIC WIRING.................................................................... 12 4.4.2 POWER CONNECTION ....................................................................................................................... 13 4.4.3 RS485 SERIAL CONNECTION (only with wiper option) ................................................................. 13 4.4.4 ELECTRICAL WIRING .......................................................................................................................... 14 4.4.5 ELECTRICAL HEATERS CONFIGURATION.................................................................................... 15 4.4.6 WIPER CONNECTION (OPTIONAL).................................................................................................. 16 4.5 CLOSING THE HOUSING ............................................................................................................................ 17 4.5.1 CLOSING THE HOUSING WITH A WIPER (OPTIONAL)............................................................... 17
5
TECHNICAL FEATURES............................................................................................18 5.1 HOUSING DIMENSIONS.............................................................................................................................. 18 5.1.1 Standard version .................................................................................................................................... 18 5.1.2 Wiper version .......................................................................................................................................... 19 5.2 COMMON TECHNICAL SPECIFICATIONS .............................................................................................. 19 5.3 USEFULL WINDOWS AREA........................................................................................................................ 20
TEKNOSYSTEM
91030107/12-2012
2
CHXESP – CHXESP+W – HOUSING KIT
INSTRUCTION MANUAL
SECURITY 1.1
Symbols ATTENTION Indicates a potentially dangerous situation that, if ignored, could lead to physical or mortal injuries and/or damage to the device. Read the provided instructions carefully.
ELECTRICAL HAZARDS Indicates a potentially dangerous situation involving electricity risks that could lead to physical or mortal injuries and/or damage to the device. Read the provided instructions carefully.
MECHANICAL HAZARDS Indicates a potentially dangerous situation involving mechanical risks that could lead to physical or mortal injuries and/or damage to the device. Read the provided instructions carefully.
INFORMATION Indicates a series of information such as, for instance, advice on how to use and install the device.
1.2
General information
The device must: - be installed and maintained by authorised and qualified operators only - be mounted on suitable buildings and structures - be installed in a position that only qualified technical operators can access as the moving parts can cause injuries - be disconnected from the mains before commencing any installation and maintenance work Please look after this manual and keep it for future reference.
TEKNOSYSTEM
91030107/12-2012
3
CHXESP – CHXESP+W – HOUSING KIT
2
INSTRUCTION MANUAL
DESCRIPTION
Stainless steel housing to provide video surveillance of indoor and outdoor environments, especially where the need to guarantee specific resistance to corrosion can only be met by using 100% AISI 316L stainless steel solutions. The unit is simple to install, it is highly versatile and easy to customise.
3
CONTENTS OF THE BOX
3.1
OPENING THE BOX
Check that the box shows no signs of damage incurred during transportation; report any anomalies to the freight forwarder immediately. Check that all parts listed in Chapter §3.2 CONTENTS OF THE BOX are included in the box. The container is specifically designed for shipping this device and should be used during all handling phases, including in the event that the device is faulty and must be returned. When replacing the device in the box, follow the instructions indicated inside the box.
3.2
CONTENTS OF THE BOX
The following should be found inside the box: - 1 housing + bracket unit - 1 Instruction manual - 1 bag containing: - a CDROM (only with wiper option) - bracket screws - housing screws
3.3
EQUIPMENT NEEDED
The following tools are required to assemble the device: - 3 mm Allen wrench - 6 mm Allen wrench - small flathead screwdriver
TEKNOSYSTEM
91030107/12-2012
4
CHXESP – CHXESP+W – HOUSING KIT
4
INSTRUCTION MANUAL
ASSEMBLY DANGER The power and signal cables must be fastened in place at regular intervals, so that the weight is distributed along the entire cable wiring route and does not depend on the cable glands alone.
Decide the installation position and check that it is suitable for the device to be mounted: on a wall, on a pole with a specific adapter or a corner clamp. Check there is enough room for the device to perform its movements.
4.1
WALL MOUNTING
Place the bracket in its intended position against the wall and mark the points for the fixing holes. Drill the fixing holes accounting the building material of the wall and type of expansion bolt required. Fix the bracket on the wall.
4.2
POLE MOUNTING
Fix the bracket to the pole mounting adapter by using the bracket screws.
TEKNOSYSTEM
91030107/12-2012
5
CHXESP – CHXESP+W – HOUSING KIT
4.3
INSTRUCTION MANUAL
SEPARATING/JOINING THE BRACKET
Remove the housing and the bracket from the box. Loosen the three fastener screws (1) so they are disengaged. Remove the lower section.
4.3.1 OPENIG THE HOUSING Loosen the two screws in front of the housing until disconnection (about 13mm) from the rear cap. The screws will remain fixed to the front cap.
Forcing the resistance of the front by using a screwdriver to be inserted into the slot you can find between the front and the housing body. The front is linked to the housing by means of a cable.
Forcing the resistance of the rear by using a screwdriver to be inserted into the slot you can find between the rear and the housing body. At this point you can remove the front cap and the tube making them independent from the internal frame. You will be able to have the internal frame available for joining the bracket and the camera
TEKNOSYSTEM
91030107/12-2012
6
CHXESP – CHXESP+W – HOUSING KIT
INSTRUCTION MANUAL
JOINING THE BRACKET
4.3.1.1 CHOOSING THE RIGHT BRACKET POSITION The bracket can assume different positions and has two basic mounting configuration in order to let moving the housing in all the positions required. Bracket configuration
Housing movement
Bracket position
Housing movement
Bracket position
CONFIGURATION 0
CONFIGURATION 0
Bracket configuration
CONFIGURATION 1
CONFIGURATION
1
TEKNOSYSTEM
91030107/12-2012
7
CHXESP – CHXESP+W – HOUSING KIT
INSTRUCTION MANUAL
4.3.1.2 CHANGE THE CONFIGURATION OF THE BRACKET
CONFIGURATION 0
Take the bracket and put it in position like the picture.
Remove the screws, remove and reverse the first part.
Fix the part. The bracket must be like in the picture.
CONFIGURATION 1
TEKNOSYSTEM
91030107/12-2012
8
CHXESP – CHXESP+W – HOUSING KIT
INSTRUCTION MANUAL
4.3.1.3 CABLES ENTRY Warning: • cable diameter minimum 4.5mm to maximum 10mm. • recommended tightening torque for the cable gland lock nuts is 6 Nm Put the bracket in this position. This will help the entry of the cables.
Insert the cables.
Loosen the lock nut on the cable glands. Feed the connecting cables through the hole in the cable gland, M16x1.5m Fix the glands.
TEKNOSYSTEM
91030107/12-2012
9
CHXESP – CHXESP+W – HOUSING KIT
INSTRUCTION MANUAL
4.3.1.4 FIXING THE HOUSING FRAME TO THE BRACKET Choose the correct bracket/housing position and fix the housing to the bracket by using the screws.
TEKNOSYSTEM
91030107/12-2012
10
CHXESP – CHXESP+W – HOUSING KIT
INSTRUCTION MANUAL
4.3.2 INSTALLING THE VIDEO CAMERA Use the ¼” screws (6) and the insulating washers (4, 5) supplied in the pack, to attach the video camera to the internal slide (3). Use the insulating spacer (2) to fasten the video camera (1) in place.
TEKNOSYSTEM
91030107/12-2012
11
CHXESP – CHXESP+W – HOUSING KIT
4.4
INSTRUCTION MANUAL
ELECTRICAL CONNECTIONS DANGER All electrical connections must be performed by suitably qualified technicians, in accordance with the laws enforced in the location where the device is installed.
DANGER Install a bipolar thermal-magnetic circuit breaker at a distance of at least 3 mm for each installed unit. This circuit breaker switch must be used to disconnect the unit from the main power supply.
DANGER The power and signal cables must be fastened in place at regular intervals, so that the weight is distributed along the entire cable laying route and does not depend on the cable glands alone.
No unauthorised individuals must be allowed access to the power cables.
4.4.1 CABLING INSTRUCTIONS FOR ELECTRIC WIRING To connect the mains power cable, proceed as follows: - cut the power cable so that the earth wire is at least 25 mm longer than the other two wires. Connect it to the earth terminal to ensure it is the last wire to disconnect should the cable be stretched. - Install a bipolar thermal-magnetic circuit breaker at a distance of at least 3 mm for each unit. This differential switch must be used to disconnect the unit from the mains. To connect the remaining signal cable, proceed as follows: - connect them to their relative terminals - group all the cables together near the terminals - keep the signal cables well apart from the mains power cable.
TEKNOSYSTEM
91030107/12-2012
12
CHXESP – CHXESP+W – HOUSING KIT
INSTRUCTION MANUAL
4.4.2 POWER CONNECTION The unit foresees three types of power supply: 24Vac, 110Vac and 230Vac. Before commencing the connection procedure, check that the voltage coincides with that required for the device being installed. Disconnect all power supplies before starting the connection process. Cut off all power supplies using the disconnecting switch. The power cable should be selected according to the type of installation, for example: distance, operating temperature, indoor or outdoor installation and conformity with electrical power rules and regulations enforced in the country of installation. Always use a dual-insulation power cable Recommended cable : H05RN-F 1mm² 3G1 (-20°C/+60°C) or H07RN-F 1mm² 3G1 (-40°C/+60°C). Terminal L N
Power supply: 24Vac --Yellow/green
Power supply: 110/230Vac Brown Blue Yellow/green
4.4.3 RS485 SERIAL CONNECTION (only with wiper option) Use a suitable cable and connect it to the terminals as illustrated in paragraph The connection cable must have the following characteristics: - Shielded twisted pair cable (shielded net + aluminium band + earth continuity wire) - Characteristic impedance = 120Ω - Capacity <100 pf/m - Minimum cable diameter = 0,22 mm² (24AWG) The recommended cable is a BELDEN code 9481.
TEKNOSYSTEM
91030107/12-2012
13
CHXESP – CHXESP+W – HOUSING KIT
INSTRUCTION MANUAL
4.4.4 ELECTRICAL WIRING Depending on the version purchased the housing and related accessories are possible the following connections: INPUT 230 V~
PS 230//12 V
DEFOGGING UNIT
DEFOGGING UNIT
Power supply 12Vdc/24V~ 110V~/230V~ 110V~/230V~
TEKNOSYSTEM
CAMERA 12 V
HEATER 230 V~
INPUT
CAMERA
INPUT
CAMERA
24 V~ 12 V
24 V~ 12 V
110 V~ 230 V~
110 V~ 230 V~
HEATER 24 V~ 12 V
Power consumption (heating in series) 20W 40W 40W
DEFOGGING UNIT
Power consumption (heating in parallel) 40W 80W 80W
91030107/12-2012
HEATER 110 V~ 230 V~
Camera Power 12Vdc/24V~ 110V~/230V~ 12Vdc-2A
14
CHXESP – CHXESP+W – HOUSING KIT
INSTRUCTION MANUAL
4.4.5 ELECTRICAL HEATERS CONFIGURATION The camera housing allows you to choose the power for the heaters in a simple way. Act on the terminals to achieve the desired connection.
This type of connection allows the housing to work properly until a temperature of -20 ° C with a power consumption of about 20W (version 12/24Vac/dc) and 40W (version 110/230Vac).
This type of connection allows the housing to work properly until a temperature of -40 ° C with a power consumption of about 40W (version 12/24Vac/dc) and 80W (version 110/230Vac). WIPER LINK (OPTIONAL)
TEKNOSYSTEM
91030107/12-2012
15
CHXESP – CHXESP+W – HOUSING KIT
INSTRUCTION MANUAL
4.4.6 WIPER CONNECTION (OPTIONAL) Warning: • For the wiper settings please refer to the wiper programming and management manual.
TEKNOSYSTEM
91030107/12-2012
16
CHXESP – CHXESP+W – HOUSING KIT
INSTRUCTION MANUAL
CLOSING THE HOUSING Take the housing tube and insert it on the housing frame
Forcing the resistance of the rear and push the tube. The front is linked to the housing by means of a cable. Put the front in position.
Tighten the screws of the front alternately so that the rear base closes evenly on both sides.
4.4.7 CLOSING THE HOUSING WITH A WIPER (OPTIONAL) The final engagement can be performed during the insertion phase or when it is moved for the first time. Warning: • do not force the wiper manually or using any tools when it is engaged. • When the housing is closed, brush and reposition the wiper.
TEKNOSYSTEM
91030107/12-2012
17
CHXESP – CHXESP+W – HOUSING KIT
INSTRUCTION MANUAL
5
TECHNICAL FEATURES
5.1
HOUSING DIMENSIONS
5.1.1 Standard version
TEKNOSYSTEM
91030107/12-2012
18
CHXESP – CHXESP+W – HOUSING KIT
INSTRUCTION MANUAL
5.1.2 Wiper version .
TEKNOSYSTEM
91030107/12-2012
19
CHXESP – CHXESP+W – HOUSING KIT
5.2
COMMON TECHNICAL SPECIFICATIONS
Operating ambient temperature Material Applicable Safety Standard Protection rating (IP) Material Power supply
Certificates
Dimensions Weight of the housing Weight of the bracket
5.3
INSTRUCTION MANUAL
-20°C / +60°C (about 20W – heaters connected in series) -40°C / +60°C (about 40W – heaters connected in parallel) Aisi316L stainless steel EN60950 IP66 – IEC60529 AISI 316L stainless steel 24Vac 50/60Hz – 5A 110Vac 50/60Hz – 1A 230Vac 50/60Hz – 0.5A (+10/-20%) CEI EN60950-1, EN61000-6-3 and EN50130-4 FCC part 15, class B IP66 EN60529 See drawings 6kg 2.2kg
USEFUL WINDOWS AREA
Tempered glass Germanium filter VG60 Germanium filter VG80
TEKNOSYSTEM
Ø 71mm (Ø 66mm with defog unit) Ø 54mm Ø 74mm
91030107/12-2012
20