Transcript
Interface modules
12
14
LABEL
LABEL
RELAY MODULE
MODULE 6-24
V
V
A1
A1
A2
A2
SOCKET
6-24
A2
Relay module CINT-R1/CINT-R2 A1
A2(–)
COIL
Solid-state module CINT-R5/CINT-R8
(+)
MADE IN EC
A1
RELAY
NC
12 CINT 1/ UC 6-24 VU
COMAT SOCKET
14
12
11
11
Max. 6A 250V (see module)
COM
11 01
A1(+)
12
11
(+) RELAY
RELAY
CINT12/UC24V
14
NO
OUT
14
01
CINT- R2 / UC 24 VU
CINTKk
With srcew terminals (0,2-2,5mm 2) CINT-11, -12, -15, -18
14
A2
11 12
SOCKET
With cage clamp terminals (1x 0,2 - 2,5 mm 2) CINT-21, -22, -25, -28
6,2
CINT-11, CINT-21 Interface module Complete with integrated LED and switching module
MAX MIN
CINT-12, CINT-22
CINT-15, CINT-25
CINT-18, CINT-28
Interface module
Interface module
Interface module
Interface module
for PLC’s and process control. High power contact AgSnO2. With screw terminals (CINT-11) or cage clamp terminals (CINT-21).
for PLC’s and process control. Signal contact AgNi +5µ Au. With screw terminals (CINT-12) or cage clamp terminals (CINT-22).
for PLC`s and process control. DC solid-state switch NO, pnp. Integrated transient clamp circuit. For fast and high frequency switching. With screw terminals (CINT-15) or cage clamp terminals (CINT-25).
for PLC`s and process control. AC solid-state switch type NO synchronous switching triac. For fast and high frequency switching. With screw terminals (CINT-18) or cage clamp terminals (CINT-28).
10A250 6A 250VVAA
10A250 6A 250VVAA
10A24250 2A V DV A
10A250 2A 250VVAA
10 mA 12 V
1mA 1V
1mA 6V
10mA 12V
Technical data
Contact material Switching power AC1 Switching power DC1 Switching power AC15 Peak inrush current Switching cycles: mechanical/electrical Contact resistance / voltage drop Isolation
AgSnO 2 1500VA ...250W 300VA/230V 100 A/2,5 ms 10 x106 /105 <100mΩ 3600Vrms
AgNi + 5µ Au 1500VA ...250W – 10A/20ms 10x106 /105 <100mΩ 3600Vrms
Solid-state – ...60W – 20A/10ms – <100mΩ /200mV 2500Vrms
Solid-state (Triac) 500VA – – 20A/10ms – <1,5V 2500Vrms
Operation voltage AC50/60Hz / DC Power consumption Pmax. 24V Power consumption Pmax. AC230V On delay / release time Temperature: operating/storage
0,8...1,2UN 240mW 1,1W 5 ms/10 ms -20...+55 °C /-40...+85 °C
0,8...1,2UN 240mW 1,1W 5ms/10ms -20...+55°C/-40...+85°C
0,7...1,25Un 240mW – <1ms -20...+55°C/-40...+85°C
0,7...1,25Un 240mW – <1ms -20...+55°C/-40...+85°C
24, 230 CINT-12/UC.....V CINT-22/UC.....V
CINT-R2/UC110-240V CINT-R2/UC24V Connector bridge CINT- BR20
12
88,5
Connector bridge CINT- BR20 (packing unit: 10 pieces)
A1
31,5
A1
17,5
(packing unit: 64 pieces)
With srcew terminals
23,7
Marking label CINT- BEZ
14
TS 35
14
Marking label (supplied with standard delivery) CINT- BEZ
12
93,5
11
29.5
Module d’interface CINT-21/ UC 24 V
CINT-R8/DC 24V
11
35,3
Ordering example
CINT-R5/DC24V
With cage clamp terminals
44
CINT-R1/UC110-240V CINT-R1/UC24V
CINT-18/DC 24V CINT-28/DC 24V
44
Module solid-state
CINT-15/DC24V CINT-25/DC24V
17,5
≤ 10%
TS 35
DC
35,3
50/60 Hz /
24, 230 CINT-11/UC.....V CINT-21/UC.....V
23,7
UC
Ordering N0.
A2
A2
Replacement relay CINT- R1/ UC 24 V
3,4 6,2
3,4
52 72,8
6,2
52 72,8
This issue replaces all previous issues. Availability, errors and specifications subject to change without notice.
Kühn Controls AG, Gräfenhäuser Str. 14, D-75305 Neuenbürg, Tel.:+49 (0)7082-940000, Fax:+49 (0)7082-940001, www.multicomat.net
Tb CINT / 4.04 E