Preview only show first 10 pages with watermark. For full document please download

Cisco Aironet Lightning Arrestor (air-acc245la

   EMBED


Share

Transcript

DC diskontcomputer.com GmbH Traunuferstrasse 110 4052 Ansfelden, Austria :: Seite 1 von 4 :: Datenblatt zum Produkt Cisco 2.4/5GHZ Lightning Arrestor mit DC# 439390 :: Cisco Aironet Lightning Arrestor (AIR-ACC245LA-R) November 9, 2004 This document describes the lightning arrestor kit and provides instructions for mounting the arrestor. Introduction Overvoltage transients can be created through lightning static discharges, switch processes, direct contact with power lines, or through earth currents. The Cisco Aironet AIR-ACC245LA-R Lightning Arrestor limits the amplitude and duration of disturbing interference voltages and improves the overvoltage resistance of in-line equipment, systems, and components. A lightning arrestor installed according to these mounting instructions balances the voltage potential, thus preventing inductive interference to parallel signal lines within the protected system. The Cisco Aironet AIR-ACC245LA-R Lightning Arrestor is designed for use with Cisco Aironet access points and bridges but can be used Cisco Aironet radio device that utilizes an RP-TNC connector. Warnings Warning Disconnect or switch off in-line equipment when installing or inspecting lightning arrestors during an electrical storm. Warning When connecting lightning arrestors, make sure that the succeeding equipment and components are disconnected or turned off. Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Corporate Headquarters: Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA Copyright © 2004 Cisco Systems, Inc. All rights reserved. Fragen zu dem Produkt? Kein Problem - wir helfen Ihnen per eMail ([email protected]) gerne weiter! Den aktuellen Preis und Lagerstand finden Sie online auf http://www.diskontcomputer.com/detail.php?item=439390 DC diskontcomputer.com GmbH Traunuferstrasse 110 4052 Ansfelden, Austria :: Seite 2 von 4 :: Datenblatt zum Produkt Cisco 2.4/5GHZ Lightning Arrestor mit DC# 439390 :: Warning Do not work on the system or connect or disconnect cables during periods of lightning activity. Installation Considerations Cisco recommends that you bulkhead mount the lightning arrestor so it can be installed as a wall feed through on the wall of the protected space. The importance of obtaining a good ground and bonding connection cannot be overstressed. Consider these points when grounding the lightning arrestor: • Connect the lightning arrestor components directly to the grounding point. • The contact points of the ground connection must be clean and free of dust and moisture. • Tighten threaded contacts to the torque specified by the manufacturer. Installation Notes This lightning arrestor is designed to be installed between the antenna cable that is attached to an outdoor antenna and the Cisco Aironet wireless device. You can install the lightning arrestor either indoors or outdoors. It can be connected directly to a wireless device having an external RP-TNC connector. It can also be mounted inline or as a feed-through. Feed-through installations require a in. (19 mm) hole to accommodate the lightning arrestor. See Figure 1. Note This lightning arrestor is part of a lightning arrestor kit. The kit contains a lightning arrestor, a grounding lug, and this instruction sheet. Note When you install the lightning arrestor, follow the regulations or best practices applicable to lightning protection installation in your local area. Installing the Lightning Arrestor Outdoors If you install the lightning arrestor outdoors, use the supplied ground lug and a heavy wire (#6 solid copper) to connect it to a good earth ground, such as a ground rod. The connection should be as short as possible. Installing the Lightning Arrestor Indoors If you install the lightning arrestor indoors, place the wireless LAN device near a good source of ground, such as structural steel or the ground on an electrical panel. Ground the lightning arrestor by using a heavy wire (#6 solid copper) and connect the ground wire to a good ground on the structural steel or electrical panel. The connection should be as short as possible. Cisco Aironet Lightning Arrestor (AIR-ACC245LA-R) 2 78-16707-01 Fragen zu dem Produkt? Kein Problem - wir helfen Ihnen per eMail ([email protected]) gerne weiter! Den aktuellen Preis und Lagerstand finden Sie online auf http://www.diskontcomputer.com/detail.php?item=439390 DC diskontcomputer.com GmbH Traunuferstrasse 110 4052 Ansfelden, Austria :: Seite 3 von 4 :: Datenblatt zum Produkt Cisco 2.4/5GHZ Lightning Arrestor mit DC# 439390 :: Figure 1 Lightning Arrestor Details 1 2 3 117891 4 5 1 Nut 4 Protected side (to wireless device) 2 Lockwasher 5 Unprotected side (to antenna) 3 Ground lug Suggested Cable Coaxial cable loses efficiency as the frequency increases, resulting in signal loss. The cable should be kept as short as possible because cable length also determines the amount of signal loss (the longer the run, the greater the loss). Cisco recommends a high-quality, low-loss cable for use with the lightning arrestor. Cisco Aironet Lightning Arrestor (AIR-ACC245LA-R) 78-16707-01 Fragen zu dem Produkt? Kein Problem - wir helfen Ihnen per eMail ([email protected]) gerne weiter! Den aktuellen Preis und Lagerstand finden Sie online auf http://www.diskontcomputer.com/detail.php?item=439390 3 DC diskontcomputer.com GmbH Traunuferstrasse 110 4052 Ansfelden, Austria :: Seite 4 von 4 :: Datenblatt zum Produkt Cisco 2.4/5GHZ Lightning Arrestor mit DC# 439390 :: Technical Specifications Main path connectors Unprotected side: TNC-R jack (female) Protected side: TNC-R plug (male) Impedance 50Ω Frequency range 0–5850 MHz Return loss ≥ 20 dB Insertion loss ≤ 0.2 dB RF CW power <= 60 W Surge current handling capability 10 single / 5 multiple kA (test pulse 8/20 µs Residual pulse energy 250 microjoules typically (test pulse 4 kV 1.2/50 µs; 2kA 8/20 microseconds) Weight 8 oz. (0.2 kg) Operating temperature range –40 F to 185 F (–40 C to 85 C) CCSP, CCVP, the Cisco Square Bridge logo, Follow Me Browsing, and StackWise are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, and iQuick Study are service marks of Cisco Systems, Inc.; and Access Registrar, Aironet, ASIST, BPX, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity, Empowering the Internet Generation, Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, FormShare, GigaDrive, GigaStack, HomeLink, Internet Quotient, IOS, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, LightStream, Linksys, MeetingPlace, MGX, the Networkers logo, Networking Academy, Network Registrar, Packet, PIX, Post-Routing, Pre-Routing, ProConnect, RateMUX, ScriptShare, SlideCast, SMARTnet, StrataView Plus, TeleRouter, The Fastest Way to Increase Your Internet Quotient, and TransPath are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries. All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0502R) Copyright © 2004 Cisco Systems, Inc. All rights reserved. Printed in the USA on recycled paper containing 10% postconsumer waste. Cisco Aironet Lightning Arrestor (AIR-ACC245LA-R) 4 78-16707-01 Fragen zu dem Produkt? Kein Problem - wir helfen Ihnen per eMail ([email protected]) gerne weiter! Den aktuellen Preis und Lagerstand finden Sie online auf http://www.diskontcomputer.com/detail.php?item=439390