Ckv2-mseries - Bibus Menos

   EMBED


Share

Transcript

Medium bore size cylinder with valve, double acting/single rod type CKV2 Series • Bore size: 20, 25, 32, 40 mm JIS symbol • Double acting cylinder with solenoid valve CAD DATA AVAILABLE. Specifications Descriptions Bore size Actuation mm CKV2 (standard type/with switch) 25 dia. 32 dia. 20 dia. Working fluid Compressed air 1 0.15 Max. working pressure MPa Min. working pressure MPa Withstanding pressure MPa 1.6 -5 to 60 (to be unfrozen) Rc1/8 +2.0 +2.4 0 (to 200) 0 (201 to 750) 50 to 500 50 to 430 Ambient temperature °C Port size mm Stroke tolerance Working piston speed mm/s Cushion Lubrication Allowable energy absorption J Solenoid valve specifications V Rated voltage A Starting current A Holding current Power consumption W 40 dia. Double acting/with solenoid valve 50 to 300 Rubber cushion Not required (When lubrication, use turbine oil Class 1 ISO VG32.) 0.089 0.137 0.179 0.278 AC100(50/60Hz) 0.056/0.048 0.028/0.024 AC200(50/60Hz) 0.028/0.024 0.014/0.012 DC24 2.0 2.5 2.0 0.110 ±10% Equivalent to Class B Voltage fluctuation range Insulation class • Note: AC100V/200V are available for AC110V, 220V (60Hz). Stroke length Bore size (mm) 20 dia. 25 dia. 32 dia. 40 dia. Standard stroke length (mm) Max. stroke length (mm) 25, 50, 75, 100, 150, 200 750 • Min. stroke length with switch (mm) 15(10) When one switch installed, refer to the value in ( ). Note 1: When switches are installed, minimum stroke varies depending on installation method. Note 2: For Bellows "J", the minimum stroke is 25mm. If less than 25mm stroke, please consult with CKD. Min. stroke length with switches When different surface installation When same surface installation (A) Rough sketch (B) Descriptions 20 dia. 25 dia. 32 dia. 40 dia. Grommet Terminal box Grommet Terminal box 15(10)mm 15(10)mm 30mm 32mm installation A 80mm installation B • Note 1: When one switch installed, refer to the value in ( ). 452 CKV2 Series Specifications Switch specifications SCP * 2 Proximity 2 wire Descriptions Proximity 3 wire CMK2 R2 R1 R2Y (2 color indicator) R3Y (2 color indicator) R3 Programmable controller, Programmable controller, relay, Applications Programmable controller relay, small solenoid valve IC circuit, solenoid valve DC4.5V to 28V Power voltage DC30V or less AC85V to 265V DC10 to 30V Load voltage/current 5 to 100mA 5 to 30mA DC200mA or less DC150mA or less Light LED (ON lighting) Red/green LED LED (ON lighting) CMA2 SCM SCA2 SCS CKV2 Red/green LED CAV2/ COV * 2 (ON lighting) (ON lighting) CAT 980m/s2 Max. shock resistance MDC2 Descriptions Applications MVC Reed 2 wire R0 Relay, programmable controller R4 High capacity relay, solenoid valve R5 Programmable controller, relay, IC circuit (without indicator light), serial connection SMD2 R6 Programmable controller (DC self hold type) MSD/ MSDG SSD Power voltage Load voltage/current Light Max. shock resistance DC12/24V, 5 to 50mA AC110V, 7 to 20mA AC220V, 7 to 10mA AC110V, 20 to 200mA AC220V, 10 to 200mA LED ON lighting Neon light OFF lighting DC5/12/24V, 50mA or less AC110V, 20mA or less AC220V, 10mA or less None SSD (large) DC24V, 5 to 50mA FC * ULKP/ ULK JSK2/ JSM2 JSC3 (medium) JSC3 (large) LED ON lighting 294m/s2 Note: Please refer to Ending 1 about other switches specifications. Cylinder mass (Unit: Kg) JSB3 Product mass when stroke length (S) =0mm Descriptions/mounting style Basic type (00) Axial foot type (LB) Rod side flange (FA) Rod side trunnion (TA) Head side trunnion (TB) Bore size (mm) 0.63 0.53 0.52 0.49 20 dia. 0.47 0.79 0.72 0.67 0.60 25 dia. 0.57 0.84 0.77 0.72 0.65 32 dia. 0.62 1.08 0.96 0.97 0.85 40 dia. 0.81 (E. g.) product mass of CKV2-FA-32-50-1-R0-D When S=0mm, product mass Additional mass at S=50mm Mass of two switches Product mass Switch mass Additional mass Grommet Terminal box per S=10mm 0.04 0.03 0.01 0.04 0.03 0.01 0.04 0.03 0.02 0.04 0.03 0.02 0.77kg Product stroke length (50) Additional mass at S =10mm 0.02 X =0.10kg 10 0.08kg 0.77kg + 0.1kg + 0.08kg =0.95kg UCAC STS/ STL LCS LCY STR2 UCA2 STK USSD USC MFC GLC SHC CAC3 HCM HCA MRL2 SRL2 SRG SRM SRT SRB2 with valve Medium bore size cylinder 453 CKV2 Series How to order Without switch CKV2 LB 20 25 U 1 LB 20 25 U 1 J I J I With switch CKV2 R0 R Symbol Mounting style Selection guide 00 Basic type LB Axial foot type FA Rod side flange type TA Rod side trunnion type TB Head side trunnion type Bore size (mm) B B Bore size 20 20 dia. 25 25 dia. 32 32 dia. 40 40 dia. Stroke length (mm) C C Stroke length Descriptions Mounting style A A 25 25 50 50 75 75 100 100 150 150 200 200 How to wire D How to wire Blank Grommet U Voltage 1 AC100V 2 AC200V 3 Switch model No. Note 1 Grommet type Terminal box type Std. type Splash-prf. R1 * R1B R1A R2 * R2B R2A R2Y * R2YB – R3 * R3B R3A R3Y * R3YB – R0 * R0B R0A R4 * R4B R4A R5 * R5B R5A R6 * R6B R6A Caution for model No. selection *Lead wire length Note 1: Surge suppressor (G) is attached for grommet lead type. Note 2: Type with indicator light (E) is available only for DIN terminal (U). Note 3: Instantaneous maximum temperature is the temperature when spark and spatter etc. instantaneously contact to bellows. Blank 1m (standard) 3m (option) 3 Switch quantity CKV2-LB-20-25-U-1-R0-R-JI Model: Medium bore size cylinder with valve, double acting/single rod A Mounting style : Axial foot type B Bore size : 20mm C Stroke length : 25mm D Wiring method : DIN terminal E Voltage : AC100V F Switch model No: Reed R0 switch, lead wire 1m G Switch quantity : One on rod side H Option : Bellows for maximum ambient temperature 100 °C I Accessory : Rod eye 454 H Option Note 1/Note 2/Note 3 R One on rod side H One on head side D Two Accessory 2 wire 2 color indicator 1 color indicator 2 color indicator 3 wire 1 color indicator 2 wire Three Option H Max. ambient Instant max. J Bellows 100°C 200°C L Bellows 250°C 400°C M Piston rod material change (stainless steel) W Silencer G Surge suppressor E Indicator light X Retract at energized P6 I 1 color indicator Lead wire Switch quantity T Display 5m (option) 5 G G Contact F DC24V Switch model No. F Proximity E DIN terminal Voltage E Reed D Copper and PTFE free Accessory I I Rod eye Y Rod clevis B2 Clevis bracket B3 Clevis bracket (clevis type) CKV2 Series How to order How to order switch SCP * 2 • Switch only • Switch main body + mounting bracket CKV2 RO 20 F B SW CMK2 • Mounting bracket RO R CKV2 F CMA2 20 SCM B SCA2 Switch model No. (previous page F ) Bore size (previous page B ) Bracket Switch model No. (previous page F ) Bore size (previous page B ) CAT MDC2 RB MVC • For R * A SW CKV2 CAV2/ COV * 2 • Terminal box only • For R * B SW SCS SMD2 RA MSD/ MSDG SSD SSD (large) FC * How to order mounting bracket Bore size (mm) Mounting bracket Axial foot type (LB), rod side Axial foot type (LB), head side Flange (FA) Trunnion (TA) Bolt for head side trunnion (TB) 20 dia. 25 dia. 32 dia. 40 dia. M1-LB-20 M1-LBV-20 M1-FA-20 M1-TA-20 M1-TB-20 M1-LB-30 M1-LBV-30 M1-FA-30 M1-TA-30 M1-TB-30 M1-LB-30 M1-LBV-30 M1-FA-30 M1-TA-30 M1-TB-30 M1-LB-30 M1-LBV-40 M1-FA-30 M1-TA-40 M1-TB-40 • Note: A mounting nut and a toothed washer are attached to the mounting bracket. ULKP/ ULK JSK2/ JSM2 JSC3 (medium) JSC3 (large) JSB3 UCAC STS/ STL LCS LCY STR2 UCA2 STK USSD USC MFC GLC SHC CAC3 HCM HCA MRL2 SRL2 SRG SRM SRT SRB2 with valve Medium bore size cylinder 455 CKV2 Series Internal structure and parts list • CKV2 (with switch) 1 No. Parts name 1 Rod nut 2 Piston rod 3 Rod packing 4 Bush 5 Rod cover 6 7 8 Cylinder tube 9 10 11 12 13 14 15 16 3 4 29 30 2 5 Material Steel 20, 25 dia., stainless steel 32, 40 dia., carbon steel Nitrile rubber Dry bearing SBK2118 Aluminum alloy Stainless steel Cushion rubber Urethane rubber Aluminum alloy Piston A Nitrile rubber Piston seal Plastic Magnet Polyacetal Wear ring Piston B Spacer Hexagon nut Aluminum alloy Steel Steel Head cover O ring Aluminum alloy Nitrile rubber 28 6 27 31 32 7 8 9 Remarks ZINC chromate Industrial chrome plated PDU 20 dia. Note 1 25, 32, 40 mm bore Chromate PSD Chromate ZINC chromate ZINC chromate 33 10 16 11 18 17 12 13 19 14 Remarks ZINC chromate ZINC chromate ZINC chromate Valve repair parts list Kit number CKV2-VK 456 Repair parts number 21 22 24 22 23 24 25 15 Material Remarks 17 18 Adaptor Cap Steel Blackening 19 20 Aluminum alloy Valve body Speed adjustment needle Brass 21 22 23 Spool assembly Piston assembly 24 25 26 Plunger assembly Coil assembly Core assembly 27 28 29 Path pipe Joint 31 Switch main body 32 33 Band Aluminum alloy die casting Pie valve body Nylon Nylon GWJL -6-6 Steel 30 Toothed washer Steel With switch Nut Stainless steel Pan head machine screw Steel Mounting bracket material Material Steel Steel Steel 21 No. Parts name Note 1: For copper and PTFE free specifications, oil impregnated cast iron bearing is used. Mounting style LB FA TA 20 • Note: Mounting bracket is attached to product, when shipping. ZINC chromate ZINC chromate 26 CKV2 Series Double acting/single rod type Dimensions SCP * 2 (File name: Page 470 or Ending 118) CMK2 MN • R type with switch, basic type (00) CMA2 SCM (Width across flats) SCA2 MO SCS X + stroke length HA (Nut width across flats) A WF C V LL + stroke length 16 RD 30 96 30 CKV2 Rc1/8 (Air supplying port) HD 17 8 CAV2/ COV * 2 (3 M5 X 0.8 (Exhaust port) 3) T CAT MVC SMD2 P 38 D dia. (H) MM dia. 22 MDC2 TG MSD/ MSDG Width across flats B Width across flats U M Z dia. KK F dia. SSD MB SSD (large) Width across flats Y FC * • R type switch terminal box, basic type (00) (3 ULKP/ ULK JSK2/ JSM2 JSC3 (medium) JSC3 (large) 3) 22 RD 44.5 44.5 HD P1 15 JSB3 UCAC STS/ STL LCS LCY STR2 UCA2 Note: Please refer to P.469 about dimensions with bellows. STK USSD Symbol Bore size (mm) 20 dia. 25 dia. 32 dia. 40 dia. Symbol Bore size (mm) 20 dia. 25 dia. 32 dia. 40 dia. Basic type (00) basic dimensions A B F (H) HA KK LL M MB MM MN MO T TG U V 20 23 23 25 13 17 17 19 18 21.4 20 26.4 20 33.6 22 41.6 With switch C D 28 32 36 45 38.5 38.5 38.5 43.0 26 35 35 35 M8 X 1.0 M10 X 1.25 M10 X 1.25 M12 X 1.5 67 70 70 74 M8 M8 M8 M10 M18 X 1.5 M26 X 1.5 M26 X 1.5 M26 X 1.5 10 12 12 14 8 10 10 12 5 5 5 6 5 6 6 7 29 41 41 41 24 30 34 43 14 16 16 16 WF 24 23 23 23 X 207 212 212 218 P 32.9 34.5 38.1 42.1 Y 34 34 34 34 Z 36 36 36 45 RD 2.0 3.5 3.5 5.5 P1 50.7 53.2 56.8 60.8 USC MFC GLC SHC CAC3 HCM HD 2.0 3.5 3.5 5.5 HCA MRL2 SRL2 SRG SRM SRT SRB2 with valve Medium bore size cylinder 457 CKV2 Series Dimensions (File name: Page 470 or Ending 118) MN • Axial foot type (LB) (Width across flats) MO P HA(Nut width across flats) A WF C V X + stroke length LL + stroke length 16 RD 30 30 96 Rc1/8 (Air supplying port) HD 17 8 3) (3 M5 X 0.8 (Exhaust port) F dia. 38 LF TG LH 3.2 D dia. (H) 22 MM dia. T KK LR Width across flats U LM LC LB 4- LD dia. LV LS LW Width across flats B LG + stroke length LK Note: Please refer to P.469 about dimensions with bellows. Symbol Bore size (mm) 20 dia. 25 dia. 32 dia. 40 dia. Symbol Bore size (mm) 20 dia. 25 dia. 32 dia. 40 dia. Axial foot type (LB) basic dimensions D A B C (H) HA KK 20 13 18 23 23 25 17 17 19 20 20 22 LH 25 30 LK 126 126 LM 7.5 8.5 30 30 126 129 8.5 8 21.4 38.5 26.4 38.5 33.6 38.5 MM MN MO T V 67 10 8 5 5 14 10 10 12 5 5 6 6 6 7 16 16 16 26 M 8 X 1.0 M10 X 1.25 70 41.6 43 35 35 35 12 12 14 M12 X 1.5 74 With switch LR 30 LS 44 LV 22 LW 29.5 F 28 TG 29 U 24 RD 2.0 P 32.9 HD 2.0 46 46 46 62 62 62 22 22 25 29.5 29.5 35 32 36 45 41 41 41 30 34 43 3.5 3.5 5.5 34.5 38.1 42.1 3.5 3.5 5.5 M10 X 1.25 70 WF 24 23 X 207 212 LB 10 12 23 23 212 218 12 12 LC 18 23 23 LD 6 7 7 LF 6 0 0 23 7 0 LG 55 63 63 64 (File name: Page 470 or Ending 118) MN • Rod side flange type (FA) Mounting dimensions LL (Width across flats) MO X + stroke length P HA(Nut width across flats) A WF C V LL + stroke length 16 RD 30 30 HD 17 96 Rc1/8 (Air supplying port) 8 3) (3 2 2 4-FD FM Width across flats B Z dia. FT FF 38 D dia. KK FL F dia. FH FC (H) FP M5 X 0.8 (Exhaust port) MM dia. T Width across flats U Width across flats Y FG + stroke length Note: Please refer to P.469 about dimensions with bellows. Symbol Bore size (mm) 20 dia. 25 dia. 32 dia. 40 dia. Symbol Bore size (mm) 20 dia. 25 dia. 32 dia. 40 dia. 458 Rod side flange type (FA) basic dimensions D A B C (H) HA KK LL 20 23 23 13 17 17 18 20 20 25 19 22 FL 40 64 64 64 FM 54 80 80 80 FT 3.2 4.5 4.5 4.5 21.4 38.5 26.4 38.5 33.6 38.5 41.6 43 FP 29 41 41 41 F 28 32 36 45 MN MO T V 10 12 12 8 10 10 5 5 5 5 6 6 14 16 16 74 14 12 6 7 16 Z 36 36 36 45 RD 2.0 3.5 3.5 5.5 P 32.9 34.5 38.1 42.1 HD 2.0 3.5 3.5 5.5 26 M 8 X 1.0 67 35 M10 X 1.25 70 35 M10 X 1.25 70 35 M12 X 1.5 With switch U 24 30 34 43 Y 34 34 34 43 Mounting dimensions MM WF 24 23 23 23 X 207 212 212 218 FC 20 28 28 28 FD FF FG FH 6 20.8 166.2 34 7 7 7 18.5 170.5 18.5 170.5 18.5 174.5 44 44 44 CKV2 Series Double acting/single rod type Dimensions SCP * 2 (File name: Page 470 or Ending 118) MN • Rod side trunnion type (TA) CMK2 CMA2 (Width across flats) P MO A WF C V HA(Nut width across flats) 16 RD 30 30 Rc1/8 (Air supplying port) HD 17 8 22 CKV2 CAV2/ COV * 2 CAT MDC2 TM KK TL TE TN Bore size (mm) 20 dia. 25 dia. 32 dia. 40 dia. Symbol Bore size (mm) 20 dia. 25 dia. 32 dia. 40 dia. 38 Width across flats U TF MM MN MO T V 21.4 38.5 26.4 38.5 33.6 38.5 26 M 8 X 1.0 67 35 M10 X 1.25 70 35 M10 X 1.25 70 35 M12 X 1.5 74 10 12 12 8 10 10 5 5 5 6 14 12 5 6 6 7 14 16 16 13 18 23 23 25 17 17 19 20 20 22 TH 29.5 TL 8 39 39 44 12 12 9.5 TM 30 40 40 41.6 43 With switch 53 SSD SSD (large) Note: Please refer to P.469 about dimensions with bellows. Rod side trunnion type (TA) basic dimensions D A C B LL (H) HA KK 20 SMD2 MSD/ MSDG Width across flats Y TG + stroke length Width across flats B Symbol MVC Z dia. TL F dia. TH D dia. TDd9 dia. SCS M5 X 0.8 (Exhaust port) MM dia. T SCA2 96 TB 3) (3 (H) SCM X + stroke length LL + stroke length Mounting dimensions WF 24 23 X 207 212 23 23 212 218 16 FC * TB 4.5 5.5 5.5 TD 8 10 10 TE 9 11 11 TF TG 19.5 167.5 17.5 171.5 17.5 171.5 5.5 10 11 17.5 175.5 ULKP/ ULK JSK2/ JSM2 JSC3 (medium) JSC3 (large) JSB3 UCAC F 28 32 U 24 30 TN 46 64 Y 34 34 Z 36 36 RD 2.0 3.5 P 32.9 34.5 HD 2.0 3.5 STS/ STL 36 45 34 43 64 72 34 43 36 45 3.5 5.5 38.1 42.1 3.5 5.5 LCY LCS STR2 • Rod side trunnion type (TA) with bracket (option symbol B2) MN UCA2 (Width across flats) STK MO TN TM TL HA(Nut width across flats) A WF C V (3 30 30 USC Rc1/8 (Air supplying port) HD 17 8 MFC M5 X 8 (Exhaust port) TB GLC SHC CAC3 HCM 38 D dia. TDd9 dia. T MM dia. 22 (H) 16 RD 96 TE 3) HCA 7 KK Z dia. 50 P TH USSD LL + stroke length TG + stroke length TF 7.5 TL X + stroke length Width across flats Y MRL2 SRL2 5 3. R Width across flats B 20 20 10 20 TR 7.5 40 TS SRM SRT 7.5 55 Rod side trunnion type (TA) with bracket (option symbol B2) basic dimensions A B C (H) HA KK 13 17 17 19 18 20 20 22 21.4 38.5 26.4 38.5 33.6 38.5 41.6 43 26 35 35 35 M 8 X 1.0 32 dia. 40 dia. 20 23 23 25 D Symbol Bore size (mm) 20 dia. 25 dia. 32 dia. 40 dia. TH 29.5 39 39 44 TL 8 12 12 9.5 TM 30 40 40 53 TN 46 64 64 72 TR 70 80 80 93 TS 90 100 100 113 SRB2 Note: Please refer to P.469 about dimensions with bellows. LL 67 M10 X 1.25 70 M10 X 1.25 70 M12 X 1.5 74 With switch Y Z 34 36 34 36 34 36 43 45 MM MN MO T V 10 12 12 14 8 10 10 12 5 5 5 6 5 6 6 7 14 16 16 16 RD 2.0 3.5 3.5 5.5 P 32.9 34.5 38.1 42.1 HD 2.0 3.5 3.5 5.5 Mounting dimensions WF 24 X 207 TB 4.5 TD 8 TE 9 TF TG 19.5 167.5 23 23 23 212 212 218 5.5 5.5 5.5 10 10 10 11 11 11 17.5 171.5 17.5 171.5 17.5 175.5 with valve Medium bore size cylinder Symbol Bore size (mm) 20 dia. 25 dia. SRG 3.2 10 459 CKV2 Series Dimensions MN • Head side trunnion type (TB) (File name: Page 470 or Ending 118) (Width across flats) MO X + stroke length V 16 RD 96 30 30 TM TL Rc1/8 (Air supplying port) HD 17 K TL 8 M5 X 0.8 (Exhaust port) TDd9 dia. 38 D dia. MM dia. 22 T (H) C TN LL + stroke length (BH) WF (3 3) A F dia. MB Z dia. P KK Width across flats U TJ + stroke length Width across flats B 26 Note: Please refer to P.469 about dimensions with bellows. Mounting dimensions Head side trunnion type (TB) basic dimensions A B BH C D (H) K KK Symbol Bore size (mm) 20 dia. 25 dia. 32 dia. 40 dia. 14 Z 36 36 RD 2.0 3.5 P 32.9 34.5 HD 2.0 3.5 34 36 3.5 38.1 3.5 43 45 5.5 42.1 5.5 13 57.5 18 23 23 25 17 17 19 57.5 57.5 62 20 20 22 41.6 43 With switch TL 8 TM 44 44 44 TN 60 64 64 F 28 32 U 24 30 36 53 73 45 10 10 10 32 dia. 40 dia. 12 14 14 M 8 X 1.0 67 M10 X 1.25 70 M10 X 1.25 70 M12 X 1.5 74 20 Symbol Bore size (mm) 20 dia. 25 dia. 21.4 38.5 26.4 38.5 33.6 38.5 LL MB MM MN MO T V WF X TD TJ M18 X 1.5 M26 X 1.5 10 8 5 5 14 12 12 14 10 10 12 5 5 6 6 6 7 16 16 16 24 23 23 207 212 212 8 10 10 83 85 85 23 218 10 89 M26 X 1.5 M26 X 1.5 (Width across flats) MO C V X + stroke length TN LL + stroke length 16 RD 30 30 96 Rc1/8 (Air supplying port) HD 17 8 M5 X 0.8 (Exhaust port) TL 38 D dia. 7 50 Width across flats U TJ + stroke length 7.5 MB F dia. P KK TM TDd9 dia. MM dia. K T TL (3 3) WF 22 A (H) MN • Head side trunnion type (TB) with bracket (option symbol B2) 26 Width across flats B 5 3.2 3. R 20 7.5 10 20 20 7.5 40 10 TR 55 TS Note: Please refer to P.469 about dimensions with bellows. Symbol Head side trunnion type (TB) with bracket (option symbol B2) basic dimensions K KK LL MB MM MN MO T V WF X TD TJ TL 12 M 8 X 1.0 M10 X 1.25 67 70 M18 X 1.5 M26 X 1.5 10 12 8 10 5 5 5 6 14 16 24 207 8 83 20 22 21.4 38.5 26.4 38.5 33.6 38.5 41.6 43 M10 X 1.25 14 M12 X 1.5 With switch 70 74 M26 X 1.5 M26 X 1.5 12 14 10 12 5 6 6 7 16 16 23 23 23 212 212 218 10 10 10 85 85 89 8 10 10 TR 84 84 84 93 TS 104 104 104 113 A B C 20 23 13 17 18 20 32 dia. 40 dia. 23 25 17 19 Symbol Bore size (mm) 20 dia. 25 dia. 32 dia. 40 dia. TM 44 44 44 53 TN 60 64 64 73 460 D Mounting dimensions (H) Bore size (mm) 20 dia. 25 dia. F 28 32 36 45 14 14 U 24 30 34 43 RD 2.0 3.5 3.5 5.5 P 32.9 34.5 38.1 42.1 HD 2.0 3.5 3.5 5.5 10 CKV2 Series Double acting/single rod type Dimensions SCP * 2 • Head side trunnion type (TB) with bracket (option symbol B3) CMK2 MN CMA2 SCM (Width across flats) SCA2 MO LL + stroke length WF V 16 RD 30 102 30 TL HD 17 8 22 Width across flats B CAT (H) 40 MDC2 MVC R3.5 SMD2 MSD/ MSDG Z dia. MB F dia. KK CKV2 CAV2/ COV * 2 TDd9 dia. D dia. T SCS TL 4.5 MM dia. K TM 55 C TN (3 3) A ZZ + stroke length Width across flats U TJ + stroke length 110 26 10 20 SSD 7 20 10 SSD (large) TR FC * TS Note: Please refer to P.469 about dimensions with bellows. Symbol Bore size (mm) 20 dia. Mounting dimensions Head side trunnion type (TB) with bracket (option symbol B3) basic dimensions A B C 25 dia. 32 dia. 40 dia. 20 23 23 25 13 17 17 19 18 20 20 22 Symbol Bore size (mm) 20 dia. 25 dia. 32 dia. 40 dia. 21.4 38.5 12 26.4 38.5 14 33.6 38.5 14 41.6 43 14 With switch TM 44 44 44 53 TN 60 64 64 73 TR 84 84 84 93 TS 104 104 104 113 D (H) F 28 32 36 45 K U 24 30 34 43 LL KK 67 M10 X 1.25 70 M10 X 1.25 70 M12 X 1.5 74 M 8 X 1.0 RD 2.0 3.5 3.5 5.5 HD 2.0 3.5 3.5 5.5 MB MM M18 X 1.5 10 M26 X 1.5 12 M26 X 1.5 12 M26 X 1.5 14 MN MO T V WF 8 10 10 12 5 5 5 6 5 6 6 7 14 16 16 16 24 23 23 23 ZZ TD TJ -0.040 8-0.076 83 -0.040 218 10-0.076 85 -0.040 218 10-0.076 85 -0.040 224 10-0.076 89 213 TL 8 10 10 10 ULKP/ ULK JSK2/ JSM2 JSC3 (medium) JSC3 (large) JSB3 UCAC STS/ STL LCS LCY STR2 UCA2 STK USSD USC MFC GLC SHC CAC3 HCM HCA MRL2 SRL2 SRG SRM SRT SRB2 with valve Medium bore size cylinder 461 Medium bore size cylinder with valve, double acting/non-rotating type CKV2-M Series • Bore size: 20, 25, 32, 40 mm JIS symbol • Double acting cylinder non-rotating type with solenoid valve Specifications CKV2-M Descriptions Bore size Actuation Working fluid mm 20 dia. 25 dia. Max. working pressure MPa Min. working pressure MPa Withstanding pressure MPa 40 dia. 1 0.15 1.6 -5 to 60 (to be unfrozen) Rc1/8 Ambient temperature °C Port size Stroke tolerance 32 dia. Double acting/non-rotating type Compressed air +2 0 (to mm Working piston speed mm/s Cushion Lubrication Revolvable angle tolerance note degree Allowable energy absorption J 200) +2.4 0 (201 to 750) 50 to 430 50 to 500 50 to 300 Rubber cushion Not required (When lubrication, use turbine oil Class 1 ISOVG32.) ±1.5 ±1 0.089 0.137 0.179 0.278 Note: This is the value when stroke length is 0 mm (deflection of piston rod excluded) Solenoid valve specifications Rated voltage V AC100(50/60Hz) Starting current A 0.056/0.048 Holding current A 0.028/0.024 Power consumption W Voltage fluctuation range 2.0 Insulation class AC200(50/60Hz) DC24 0.028/0.024 0.014/0.012 0.110 2.0 ±10% Equivalent to Class B 2.5 • Note: AC100V/200V types are available for AC110V, 220V (60Hz). Stroke length Bore size (mm) 20 dia. Standard stroke length (mm) 25 dia. 32 dia. 25, 50, 75 100, 150, 200 Max. stroke length (mm) Min. stroke length (mm) * 15(10) 750 40 dia. When one switch installed, refer to the value in ( ). Note 1: When switches are installed, minimum stroke varies depending on installation method. Note 2: For Bellows "J", the minimum stroke is 25mm. If less than 25mm stroke, please consult with CKD. Min. stroke length with switches When different surface installation When same surface installation (A) Rough sketch (B) Descriptions Grommet Terminal box Grommet 20 dia. 25 dia. 32 dia. 40 dia. 15(10)mm 15(10)mm 30mm • Note 1: When one switch installed, refer to the value in ( ). 462 Terminal box 32mm installation A 80mm installation B CKV2-M Series Specifications Switch specifications Descriptions Applications SCP * 2 Proximity 2 wire R1 R2 Programmable controller, relay, small solenoid valve Proximity 3 wire R2Y (2 color indicator) Programmable controller Power voltage Load voltage/current Light AC85V to 265V 5 to 100mA DC10 to 30V 5 to 30mA LED (ON lighting) R3 CMK2 R3Y (2 color indicator) CMA2 Programmable controller, relay, IC circuit, solenoid valve DC4.5V to 28V DC30V or less DC200mA or less DC150mA or less SCM SCA2 SCS CKV2 Red/green LED LED Red/green LED (ON lighting) (ON lighting) (ON lighting) CAV2/ COV * 2 CAT 980m/s2 Max. shock resistance MDC2 Reed 2 wire Descriptions Applications R0 Relay, programmable controller R4 High capacity relay, solenoid valve MVC R5 R6 Programmable controller, relay, IC circuit Programmable controller (without indicator light), serial connection (DC self hold type) SMD2 MSD/ MSDG SSD Power voltage Load voltage/current Light Max. shock resistance DC12/24V, 5 to 50mA AC110V, 7 to 20mA AC220V, 7 to 10mA LED ON lighting DC5/12/24V, 50mA or less AC110V, 20mA or less AC220V, 10mA or less AC110V, 20 to 200mA AC220V, 10 to 200mA Neon light OFF lighting SSD (large) DC24V, 5 to 50mA FC * LED ON lighting None 2 294m/s Note: Please refer to Ending 1 about other switches specifications. Cylinder mass Descriptions/mounting style Bore size (mm) 20 dia. 25 dia. 32 dia. 40 dia. (Unit: Kg) When stroke length (S)=0mm, product mass Basic type (00) Axial foot type (LB) Rod side flange (FA) Rod side trunnion (TA) Head side trunnion (TB) 0.47 0.57 0.62 0.81 0.63 0.79 0.84 1.08 0.53 0.72 0.77 0.96 0.52 0.67 0.72 0.97 0.49 0.60 0.65 0.85 ULKP/ ULK JSK2/ JSM2 JSC3 (medium) JSC3 (large) JSB3 Additional mass Switch mass UCAC Grommet Terminal box per S=10mm 0.04 0.04 0.04 0.04 0.03 0.03 0.03 0.03 0.01 0.01 0.02 0.02 When S=0mm, product mass is 0.77kg. Product stroke length (50) Additional mass at S=50mm is additional mass at S=10mm 0.02 X = 0.10kg (E. g.) product mass of CKV2-M-FA-32-50-1-R0-D 10 Mass of two switches is 0.08kg Product mass is 0.77kg + 0.1kg + 0.08kg=0.95kg STS/ STL LCS LCY STR2 UCA2 STK USSD USC MFC GLC SHC CAC3 HCM HCA MRL2 SRL2 SRG SRM SRT SRB2 with valve Medium bore size cylinder 463 CKV2-M Series How to order Without switch CKV2-M LB 20 25 U 1 LB 20 25 U 1 J Y With switch CKV2-M R0 R Symbol J Y Mounting style Selection guide 00 Basic type LB Axial foot type FA Rod side flange type TA Rod side trunnion type TB Head side trunnion type Bore size (mm) B B Bore size 20 20 dia. 25 25 dia. 32 32 dia. 40 40 dia. Stroke length (mm) C C Stroke length Descriptions Mounting style A A 25 25 50 50 75 75 100 100 150 150 200 200 How to wire D How to wire Blank Grommet U Voltage 1 AC100V 2 AC200V 3 Switch model No. Grommet type Terminal box type Standard type Splash-proof R1 * R1B R1A R2 * R2B R2A R2Y * R2YB – R3 * R3B R3A R3Y * R3YB – R0 * R0B R0A R4 * R4B R4A R5 * R5B R5A R6 * R6B R6A Caution for model No. selection Note 1: Surge suppressor (G) is attached to grommet lead type. Note 2: Type with indicator light (E) is available only for DIN terminal (U). Note 3: Instantaneous maximum temperature is the temperature when spark and spatter etc. instantaneously contact to bellows. 1 color indicator Lead wire 2 wire 2 color indicator 1 color indicator 2 color indicator 3 wire 1 color indicator 2 wire *Lead wire length 5m (option) 5 Switch quantity G G Switch quantity R One on rod side H One on head side D Two Three T H Option Note 1/Note 2/Note 3 Model: Medium bore size cylinder with valve double acting/non-rotating type A Mounting style : Axial foot type B Bore size : 20mm C Stroke length : 25mm D Wiring method : DIN terminal E Voltage : AC100V F Switch model No: Reed R0 switch, lead wire 1m G Switch quantity : One on rod side H Option : Bellows for maximum ambient temperature 100 °C I Accessory : Rod clevis 464 Display Blank 1m (standard) 3m (option) 3 CKV2-M-LB-20-25-U-1-R0-R-JY Contact F DC24V Switch model No. F Proximity E DIN terminal Voltage E Reed D Option H Max. ambient Instant max. J Bellows 100°C 200°C L Bellows 250°C 400°C W Silencer G Surge suppressor E Indicator light X Retract at energized P6 I Accessory Copper and PTFE free Accessory I I Rod eye Y Rod clevis B2 Clevis bracket B3 Clevis bracket (clevis type) CKV2-M Series How to order How to order switch • Switch only • Switch main body + mounting bracket CKV2-M R0 20 F B SW SCP * 2 • Mounting bracket R0 CKV2-M R CMK2 20 F CMA2 B SCM SCA2 Bore size (previous page B ) Switch model No. (previous page F ) Bore size (previous page B ) SCS CKV2 Switch model No. (previous page F ) Bracket CAV2/ COV * 2 CAT • Terminal box only • For R * B MDC2 MVC SW RB SMD2 MSD/ MSDG • For R * A SW RA SSD SSD (large) FC * How to order mounting bracket Bore size (mm) Mounting bracket Axial foot type (LB), rod side Axial foot type (LB), head side Flange (FA) Trunnion (TA) Bolt for head side trunnion (TB) 20 dia. 25 dia. 32 dia. 40 dia. M1-LB-20 M1-LB-30 M1-LBV-20 M1-FA-20 M1-TA-20 M1-TB-20 M1-LBV-30 M1-FA-30 M1-TA-30 M1-TB-30 M1-LB-30 M1-LBV-30 M1-FA-30 M1-TA-30 M1-TB-30 M1-LB-30 M1-LBV-40 M1-FA-30 M1-TA-40 M1-TB-40 • Note: A mounting nut and a toothed washer are attached to the mounting bracket. ULKP/ ULK JSK2/ JSM2 JSC3 (medium) JSC3 (large) JSB3 UCAC STS/ STL LCS LCY STR2 UCA2 STK USSD USC MFC GLC SHC CAC3 HCM HCA MRL2 SRL2 SRG SRM SRT SRB2 with valve Medium bore size cylinder 465 CKV2-M Series Internal structure and parts list • CKV2-M (with switch) 1 2 3 4 29 30 5 28 33 32 31 27 6 7 8 9 10 11 12 16 17 18 13 14 15 19 21 22 23 24 25 26 No. Parts name Material Remarks No. Parts name Material 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Steel Stainless steel Nitrile rubber SBK2118 Aluminum alloy Stainless steel Urethane rubber Aluminum alloy Nitrile rubber Plastic Polyacetal Aluminum alloy Steel Steel Aluminum alloy Nitrile rubber Steel ZINC chromate 18 Cap 19 Valve body 20 Speed adjustment needle 21 Spool assembly 22 Piston assembly 23 Pie valve body 24 Plunger assembly 25 Coil assembly 26 Core assembly 27 Path pipe 28 Joint 29 Nut 30 Toothed washer With switch 31 Switch main body 32 Band 33 Pan head machine screw Aluminum alloy die casting Aluminum alloy Brass Nylon Nylon GWJL6 -6 Steel ZINC chromate Steel Rod nut Piston rod Rod packing Bush Rod cover Cylinder tube Cushion rubber Piston A Piston seal Magnet Wear ring Piston B Spacer Hexagon nut Head cover O ring Adaptor Note 1 Chromate PSD Chromate ZINC chromate ZINC chromate Blackening Stainless steel Steel Note 1: When copper and PTFE free specifications, oil impregnated resin bearing is used. Mounting bracket material Mounting style LB FA TA 466 20 Material Steel Steel Steel Remarks • Note: Mounting bracket is attached to product, when shipping. ZINC chromate ZINC chromate ZINC chromate Remarks CKV2-M Series Double acting/baffle type Dimensions SCP * 2 • R Type with switch, basic type (00) CMK2 CMA2 X + stroke length A WF V C P LL + stroke length 16 RD 30 30 HD 17 8 MM dia. 96 R c 1/8 (Air supplying port) SCM SCA2 ) (33 22 M5 (Exhaust port) T SCS 38 D dia. F dia. (H) CKV2 CAV2/ COV * 2 CAT MDC2 KA Rod cross section U HA TG dia. KK MB MVC M Width across flats B SMD2 MSD/ MSDG SSD SSD (large) • R type switch terminal box, basic type (00) FC * ULKP/ ULK JSK2/ JSM2 JSC3 (medium) JSC3 (large) P1 RD 44.5 44.5 HD ) (33 22 15 P JSB3 UCAC STS/ STL KA LCS Rod sectional view LCY STR2 UCA2 Note 1: Please refer to Page 458 to 461 about dimensions of other mounting style. Note 2: Please refer to Page 469 about dimensions with bellows. Symbol Bore size (mm) Basic type (00) basic dimensions A B C D F (H) STK USSD HA KA KK LL M MB MM T TG U V WF M8 X 1.0 67 M8 M18 X 1.5 10 5 29 24 14 24 M8 M26 X 1.5 M8 M26 X 1.5 M10 M26 X 1.5 12 12 14 6 6 7 41 41 41 30 34 43 16 16 16 23 23 23 USC 20 dia. 20 13 18 21.4 28 38.5 26 8 25 dia. 32 dia. 40 dia. 23 23 25 17 17 19 20 20 22 26.4 33.6 41.7 32 36 45 38.5 38.5 43.0 35 35 35 10 10 12 X With switch RD P P1 Y Z HD HCM 207 212 212 2.0 3.5 3.5 32.9 50.7 34.5 53.2 38.1 56.8 34 34 34 36 36 36 2.0 3.5 3.5 HCA 218 5.5 42.1 60.8 43 45 5.5 Symbol Bore size (mm) 20 dia. 25 dia. 32 dia. 40 dia. M10 X 1.25 70 M10 X 1.25 70 M12 X 1.5 74 MFC GLC SHC CAC3 MRL2 SRL2 SRG SRM SRT SRB2 with valve Medium bore size cylinder 467 CKV2 Series Accessory dimensions (knuckle/bracket/pin) (File name: Page 470 or Ending 118) • Rod eye (I) Material: Steel CD H10 19 KK CB +0.1 Applicable Model No. bore size AA CA (mm) M1-I-20 20 dia. 14 30 25, 32 dia. 16 40 dia. 16 CD CH EW 10 19 12 (File name: Page 470 or Ending 118) • Clevis bracket (B2) R 12 12 Material: Steel 3.2 13 10 16 12 16 12 A +0.1 0 4.5 T EL R3.5 55 40 Y MB MC (File name: Page 470 or Ending 118) Material: Steel • Pin (P) for rod clevis CD f8 X CD 10 CL Applicable Model No. bore size AB CA CB CD CH CL KK (mm) M1-Y-20 20 dia. 17 30 8 10 19 19 M8 X 1.0 M1-Y-30 25, 30 dia. 20 36 10 12 25 25 M10 X 1.25 M1-Y-40 40 dia. 20 36 10 12 25 25 M12 X 1.5 30 20 7 50 15 MA MC 8 M8 X 1.0 13 25 10 M10 X 1.25 16 25 10 M12 X 1.5 16 12 36 36 KK CH X dia. Y dia. M1-I-30 M1-I-40 CA AB CA MB MA MC MC EW -0.2 AA CH KK Material: Steel +0.3 -0.1 CD H10 (File name: Page 470 or Ending 118) • Rod clevis (Y) MR 2-D 7.5 Note: Ones symmetry to XY axis are regarded as a couple. Model No. Applicable bore size (mm) CD MR Model No. Applicable bore size (mm) A D CD EL M1-B2-20-TA M1-B2-30-TA 20 dia. 25, 32, 40 dia. 8 10 8 11 M1-P-20 M1-P-30 20 dia. 25, 32, 40 dia. 37 46 4 4 10 12 Note: Snap ring and pin are not attached. Material: Steel • Rod end nut (NR) 30 20 110 3.2 Y Material: Steel B 7 T +0.1 0 R3.5 C 55 40 CD X Note: For rod clevis, a pin, a washer and a split pin are attached to the product. (File name: Page 470 or Ending 118) • Clevis bracket (B3) T 28 2 10.5 18 37 2.5 13 21 R 10 KK Model No. Applicable bore size (mm) CD Model No. Applicable bore size (mm) B M1-B3-20-TA M1-B3-30-TA 20 dia. 25, 32, 40 dia. 8 10 M1-NR-20 M1-NR-30 M1-NR-40 20 dia. 25, 32 dia. 40 dia. 13 17 19 Note: Snap ring and pin are not attached. 1 1 10 dia. 9 dia. • Silencer (SL-M5) Air 1 M5 (2 pcs./bag) 5 15.5 468 C KK 15 M8 X 1.0 19.6 M10 X 1.25 21.9 M12 X 1.5 T 5 6 7 CKV2 Series Accessory Dimensions: Bellows SCP * 2 CMK2 (File name: Page 470 or Ending 118) CMA2 X + + stroke length SCM WF + A SCA2 SCS b CKV2 CAV2/ COV * 2 CAT MDC2 d dia. MVC SMD2 MSD/ MSDG SSD SSD (large) FC * Note: In ULKP/ ULK JSK2/ JSM2 JSC3 (medium) JSC3 (large) dimensions, round up decimal point or less. Symbol Bellows A WF Bore size (mm) 20 dia. 25 dia. 32 dia. 40 dia. 20 23 23 25 24 23 23 23 b d 30 32 32 34 30 46 46 46 (Stroke length/3) + 6 (Stroke length/3.25) + 7 (Stroke length/3.25) + 7 (Stroke length/3.25) + 7 JSB3 UCAC STS/ STL LCS How to wire LCY Grommet STR2 DIN terminal (U)/light (E) UCA2 48 Light STK USSD 75 19 Coil USC Please use cabtire code 6 to 8 mm dia. MFC GLC SHC Note 1: For grommet type, light and surge suppressor is not provided. Note 2: Please refer to "How to wire terminal box" on Page 451 about wiring method of DIN terminal box. Note 3: Please use a round crimp terminal (M3 screw). CAC3 HCM HCA MRL2 SRL2 SRG SRM SRT SRB2 with valve Medium bore size cylinder 469