Preview only show first 10 pages with watermark. For full document please download

Cl-opt200t/r

   EMBED


Share

Transcript

CL-OPT200T/R Rev.900-759-30-00 English Camera Link⇔Optical Signal Converter CL-OPT200T/R Product Specification & Operation Manual CIS Corporation ©2013 CIS Corporation. All rights reserved. CL-OPT200T/R Rev.900-759-30-00 Table of Contents PAGE 1. Scope of Application ........................................................................................................................................... 3 2. Handling Precautions .......................................................................................................................................... 3 3. Product Outline .................................................................................................................................................. 5 3.1. Product Configuration ................................................................................................................................. 5 3.2. 4. Packaging .................................................................................................................................................. 5 Specifications ..................................................................................................................................................... 6 4.1. General Specifications ................................................................................................................................. 6 4.2. External Input/Output Signals ..................................................................................................................... 7 5. Function Settings ............................................................................................................................................... 8 6. External Connector Interface ............................................................................................................................... 9 6.1. 6pins circular connector HR10-7R-6PA (HIROSE) or equivalent (for both CL-OPT200T/R) .......................... 9 6.2. Camera Link Connector 12226-1100-00PL (SUMITOMO 3M) ......................................................................... 9 6.3. Optical Module Connector AFBR-57D9AMZ (AVAGO) (for both CL-OPT200T/R) ............................................ 10 7. LED Status Indication ....................................................................................................................................... 11 8. Selection of Power Feeding Method ................................................................................................................... 11 9. Precautions for Power Over Camera Link (PoCL) ................................................................................................ 12 10. Connection Example ......................................................................................................................................... 12 11. Dimensions ...................................................................................................................................................... 13 11.1. CL-OPT200T Dimensions ........................................................................................................................... 13 11.2. CT-OPT200R Dimensions........................................................................................................................... 14 12. Cases for Indemnity (Limited Warranty) ............................................................................................................. 15 13. Product Service ................................................................................................................................................ 15 ©2013 CIS Corporation. All rights reserved. 2 CL-OPT200T/R 1. Rev.900-759-30-00 Scope of Application This is to describe CL-OPT200T/R signal converters enable CIS camera link cameras to connect with frame grabber boards via optical fiber cables. change without prior notice. 2. All specifications contained herein are subject to Reproduction in whole or in part is prohibited. Handling Precautions The signal converters must not be used for any nuclear equipments or aerospace equipments with which mechanical failure or malfunction could result in serious bodily injury or loss of human life. Our warranty does not apply to damages or defects caused by irregular and/or abnormal use of the product. Please observe all warnings and cautions stated below. Our warranty does not apply to damages or malfunctions caused by neglecting these precautions. z CL-OPT200T can be used only with CIS camera link cameras. fixed. Output CLK of CL-OPT200R is 81MHz To capture the images, please use a frame grabber board corresponds to 85MHz. z Please use a metallic frame for heat dissipation. (The recommended size of the metallic frame: larger than H:2mm W:90mm D:90mm) CL-OPT200T/R Main Unit CL-OPT200Fixing Bracket z Do not use or store the converter in the following extreme conditions: ¾ Extremely dusty or humid places. ¾ Extremely hot or cold places (operating temperature –5℃ to +45℃) z Do not apply excessive force or static electricity that could damage the converter. z Follow the instructions in Chapter 6, “External connector interface” for connecting. Improper connection may cause damages not only to the converter but also to the connected devices. ©2013 CIS Corporation. All rights reserved. 3 CL-OPT200T/R Rev.900-759-30-00 z Confirm the mutual ground potential carefully and then connect the converter to monitors or computers. AC leaks from the connected devices may cause damages or destroy the converter. z Do not apply excessive voltage. (Use only the specified voltage.) Unstable or improper power supply voltage may cause damages or malfunction of the converter. z The voltage ripple of converter input power DC +12V±10% shall be within ±50mV. z The rising time of converter input power supply voltage shall be less than +10V, Max 60ms. Please avoid noises like chattering when rising. In case of abnormal operation, contact the distributor from whom you purchased the product. ©2013 CIS Corporation. All rights reserved. 4 CL-OPT200T/R 3. Rev.900-759-30-00 Product Outline CL-OPT200T and CL-OPT200R are signal converters enable CIS camera link cameras to connect with frame grabber boards via optical fiber cables. With optical fiber cables, data can be transmitted up to 150m length. Please be noted that only CIS cameras can be connected to CL-OPT200T/R. Key □ □ □ □ □ Features With optical fiber cables, data can be transmitted up to 150m length. Owing to optical fiber cable connection, no radio interference or grand noise would occur. Comply with Camera Link Base/Medium Standard Only CIS camera link non-PoCL and PoCL cameras can be connected. As to PoCL, there are some limitations. (Please refer to page 10 for the details.) 3.1. Product Configuration □ □ CL-OPT200T (Camera Link → Optical Signal Converter) CL-OPT200R (Optical Signal → Camera Link Converter) 3.2. Packaging □ Individual Carton □ Sub Carton (10 pieces/carton) □ Master Carton (100 pieces/carton) Note: Master carton may change depends on the quantities to be shipped per delivery. ©2013 CIS Corporation. All rights reserved. 5 CL-OPT200T/R 4. Specifications 4.1. General Specifications (1) Power Requirements Power Consumption (3) Dimensions (2) Weight (5) Camera Link Input/Output Connector (4) (6) Optical Connector Optical Fiber Cable Length (8) Supported Cameras (7) Rev.900-759-30-00 DC+12V±10% (Max voltage not to exceed 15V.) 6pins circular connector or PoCL Input (with limitation). CL-OPT200T : Typ 4.3W / CL-OPT200R : Typ 3.8W Refer to overall dimension drawing (H:25mm W:60mm D:90mm without protruding portion) (For both CL-OPT200T/R) Approx. 200g (For both CL-OPT200T/R) CL-OPT200T/R (For both CL-OPT200T/R) 12226-1100-00PL mini Camera Link connector (SUMITOMO 3M) CL-OPT200T Camera Link non-PoCL or PoCL Input Camera Link input CLK frequency: Driver IC rated 20MHz ~ 80MHz Base Configuration/Medium Configuration CL-OPT200R Camera Link Output Camera Link output CLK frequency: 81MHz fixed (Please connect with a frame grabber board corresponds to 85MHz.) Base Configuration/Medium Configuration LC duplex connector AFBR-57D9AMZ(AVAGO) Optical Module Rated: 8 Gb/s Light wavelength: 850nm Transmission Bandwidth: 6.125 Gb/s Max. 150m CIS tested Camera Link, non-PoCL, and PoCL cameras. Base Configuration Camera Series: VCC-G22/F22 (pixel clk: 49.09MHz) series VCC-G32/F32 (pixel clk: 72MHz) series VCC-G60 (pixel clk: 64MHz) series VCC-GC20/FC20 (pixel clk: 79.99MHz) series Medium Configuration Camera Series: VCC-F51/F52 (pixel lk: 72MHz) series VCC-GC60/FC60 (pixel clk: 72MHz) series VCC-GC21/FC21 (pixel clk: 80MHz) series (9) Trigger Delay (10) Video Delay (11) Serial Communications (12) Safety/Quality Standards Cannot run the camera at Full Configuration Mode. (Please contact our sales department regarding connections not listed above.) Referenced Value (measured value with Fujikura DXLC-2P-PC-(L)M-GC50/125-25R Optical cable) About 700ns (Circuit Fixed delay) + (5ns x L:Optical cable length (m)) Less than 1Line (Refer to the spec of camera to be connected.) 9600bps fixed Note: Set the frame grabber at 9600bps. UL: Conform to UL Standard including materials and others. CE: Emission: EN55022:2010 (Class B) Immunity: EN61000-6-2:2005 ©2013 CIS Corporation. All rights reserved. 6 CL-OPT200T/R Rev.900-759-30-00 RoHS: FCC: Vibration resistance (13) Durability (14) Operation Environment (15) Storage Environment Conform to RoHS To be applied Acceleration : 98m/s2 (10G) : 20~200 Hz Frequency Direction : X,Y, and Z, 3 directions Testing time : 120min for each direction Shock No malfunction shall be occurred with 980m/s2(100G) for ±X, ±Y, and ±Z, 6 directions. (without package) resistance Operation - 5 ~ +45℃ With RH 20~ 80% With no Temeprature condensastion -25 ~ +60℃ with RH20 ~ 80% with no condensation 4.2. External Input/Output Signals (1)GPIO FVAL output :No.3pin External Trigger input :No.4pin 6pins circular connector (LVTTL output) IO Interface of 6 pins circular connector at rear ©2013 CIS Corporation. All rights reserved. 7 CL-OPT200T/R 5. Rev.900-759-30-00 Function Settings With internal dip switch, trigger signals input can be selected. (1) SW2-1 ・・・ OFF : (Initial Setting) (1) SW2-2 ・・・ OFF : (Initial Setting) (2) SW2-3 ・・・ ON : 6 pins circular connector input OFF : Camera Link (CC1) input (Initial Setting) ・・・ OFF : Base/Medium (Initial Setting) ON : Do not use. ・・・ OFF : Not used Trigger input selection (3) SW3-1 Camera Link Configuration (4) SW3-2 (5) SW3-3 ・・・ ON : Not used ・・・ OFF : Not used ©2013 CIS Corporation. All rights reserved. 8 (Initial Setting) (Initial Setting) CL-OPT200T/R 6. Rev.900-759-30-00 External Connector Interface 6.1. 6pins circular connector HR10-7R-6PA (HIROSE) or equivalent (for both CL-OPT200T/R) Pin No. 1 Power Input (DC+12V) 2 Power Input (DC+12V) 3 FVAL output 4 External Trigger Input 5 GND 6 GND 6.2. Camera Link Connector 12226-1100-00PL (SUMITOMO 3M) CL-OPT200T CN1 (Camera Link In: Base side) Pin No. Pin No. 1 NC/+12V(PoCL) 14 GND 2 X0- 15 X0+ 3 X1- 16 X1+ 4 X2- 17 X2+ 5 Xclk- 18 Xclk+ 6 X3- 19 X3+ 7 SerTC+ 20 SerTC- 8 SerTFG- 21 SerTFG+ 9 CC1- 22 CC1+ 10 CC2+ 23 CC2- 11 CC3- 24 CC3+ 12 CC4+ 25 CC4- 13 GND 26 NC/+12V(PoCL) CN2 (Camera Link In: Medium Side) Pin No. Pin No. 1 NC 14 GND 2 Y0- 15 Y0+ 3 Y1- 16 Y1+ 4 Y2- 17 Y2+ 5 Yclk- 18 Yclk+ 6 Y3- 19 Y3+ 7 100Ω 20 Terminated 8 Z0- 21 Z0+ 9 Z1- 22 Z1+ 10 Z2- 23 Z2+ 11 Zclk- 24 Zclk+ 12 Z3- 25 Z3+ 13 GND 26 NC ©2013 CIS Corporation. All rights reserved. 9 13 1 26 14 CL-OPT200T/R Rev.900-759-30-00 CL-OPT200R CN1 (Camera Link Out: Base side) Pin No. Pin No. 1 GND/+12V(PoCL) 14 GND 25 X0- 12 X0+ 24 X1- 11 X1+ 23 X2- 10 X2+ 22 Xclk- 9 Xclk+ 21 X3- 8 X3+ 20 SerTC+ 7 SerTC- 19 SerTFG- 6 SerTFG+ 18 CC1- 5 CC1+ 17 CC2+ CC2- 16 CC3- CC3+ 15 CC4+ CC4- 13 GND 26 13 1 26 14 GND/+12V(PoCL) CN2 (Camera Link Out: Medium side) Pin No. Pin No. 1 NC 14 GND 25 Y0- 12 Y0+ 24 Y1- 11 Y1+ 23 Y2- 10 Y2+ 22 Yclk- 9 Yclk+ 21 Y3- 8 Y3+ 20 100Ω 7 Terminated 19 Z0- 6 Z0 18 Z1- 5 Z1+ 17 Z2- 4 Z2+ 16 Zclk- 3 Zclk+ 15 Z3- 2 Z3+ 13 GND 26 NC 6.3. Optical Module Connector AFBR-57D9AMZ (AVAGO) (for both CL-OPT200T/R) LC duplex Connector ©2013 CIS Corporation. All rights reserved. 10 CL-OPT200T/R Rev.900-759-30-00 7. LED Status Indication LED lights up when the camera, cable, fiber optic cable are linked normally. If it does not light up, please confirm the followings: z Camera link cable, camera, and fiber optic cable are not connected. z No camera link CLK input z Data transmission failed via optical transmission z No power supplied to CL-OPT200T/R 8. Selection of Power Feeding Method With internal dip switch, power feeding method can be changed. (1) CL-OPT200T SW1 ・・・ ON : Feed the power to the converter unit via 6 pins circular connector. (Initial Setting) No power is feeded to the camera. (When non-PoCL camera is connected.) OFF : Feed the power to both of the converter unit and the camera via 6pins ciruclar connector. (When PoCL or PoCL-Lite camera is connected.) (2) CL-OPT200R SW1 ・・・ ON : Feed the power to the converter unit via 6 pins circular connector. OFF : Feed the power to the converter unit via the frame grabber board. (When PoCL frame grabber board is connected.) ©2013 CIS Corporation. All rights reserved. 11 (Initial Setting) CL-OPT200T/R Rev.900-759-30-00 9. Precautions for Power Over Camera Link (PoCL) CL-OPT200R (Receiving unit) can operate with power fed via the frame grabber board, but the following specification does not meet PoCL standard. When feeding the power via PoCL, please confirm with the power feeding specifications of the frame grabber board. (1) The normal output timing of CLK output from the CL-OPT200R to the frame grabber board shall be maximum 10s after the last power input for the camera, the CL-OPT200T, or the CL-OPT200R. (2) The intermittent CLK or LVAL/FVAL from the CL-OPT200R may be output to the frame grabber board, while the camera, the CL-OPT200T, and CL-OPT200R are connected. 10. Connection Example Camera Link (Base Configuration) Camera Link Frame Grabber Bord PoCL Feeder connection Mini-CL Cable Within 3 meters Mini-CL Cable Within 3 meters 1MD26-3560-00C-300 (住友3M社製) LC duplex Optical Cable : Within 150 meters 1SD26-3120-00C-300 Power Supply (SW1) Circuit CL-OPT200R ©2013 CIS Corporation. All rights reserved. 12 CL OUT(M) OPT OUT DC IN Trigger Signal (SW2-3) CL-OPT200R CL-OPT200T Image Data DC IN CL IN(M) Circuit Trigger Signal OPT IN CL IN(B) (SW1) CL-OPT200T (SW2-3) CL OUT(B) DXLC-2P-PC-50M-GC50/125-2SR (フジクラ社製) (住友3M社製) CL-OPT200T/R 11. Rev.900-759-30-00 Dimensions 11.1. CL-OPT200T Dimensions ©2013 CIS Corporation. All rights reserved. 13 CL-OPT200T/R Rev.900-759-30-00 11.2. CT-OPT200R Dimensions ©2013 CIS Corporation. All rights reserved. 14 CL-OPT200T/R 12. Rev.900-759-30-00 Cases for Indemnity (Limited Warranty) We shall be exempted from taking responsibility and held harmless for damage or losses incurred by the user in the following cases. z In case damage or losses are caused by fire, earthquake, or other acts of God, acts by third party, deliberate or accidental misuse by the user, or use under extreme operating conditions. z In case indirect, additional, consequential damages (loss of business interests, suspension of business activities) are incurred as result of malfunction or non-function of the equipment, we shall be exempted from responsibility for such damages. z In case damage or losses are caused by failure to observe the information contained in the instructions in this product specification & operation manual. z In case damage or losses are caused by use contrary to the instructions in this product specification & operation manual. z In case damage or losses are caused by malfunction or other problems resulting from use of equipment or software that is not specified. z In case damage or losses are caused by repair or modification conducted by the customer or any unauthorized third party (such as an unauthorized service representative). z Expenses we bear on this product shall be limited to the individual price of the product. 13. Product Service In case of abnormal operation, contact the distributor from whom you purchased the product. ©2013 CIS Corporation. All rights reserved. 15