Preview only show first 10 pages with watermark. For full document please download

Cl600 2v 600ah(10hr)

   EMBED


Share

Transcript

CL600 2V 600Ah(10hr) The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte is absorbed by separators and plates and thus immobilized. Should the battery be accidentally overcharged producing hydrogen and oxygen, special one-way valves allow the gases to escape thus avoiding excessive pressure build-up. Otherwise, the battery is completely sealed and is, therefore, maintenance-free, leak proof and usable in any position. Battery Construction Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte Raw material Lead dioxide Lead ABS ABS Rubber Copper Fiberglass Sulfuric acid General Features ● ● ● ● ● ● ● ● Performance Characteristics Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintenance or water adding. Not restricted for air transport-complies with IATA/ICAO Special Provision A67. UL-recognized component. Can be mounted in any orientation. Computer designed lead, calcium tin alloy grid for high power density. Long service life, float or cyclic applications. Maintenance-free operation. Low self discharge. Dimensions and Weight Length(mm / inch) Width(mm / inch) Height(mm / inch) Total Height(mm / inch) Approx. Weight(Kg / lbs) 302 / 11.89 175 / 6.89 331 / 13.03 343 / 13.50 42 / 92.6 Nominal Voltage 2V Number of cell 1 Design Life 20 years Nominal Capacity 77oF(25oC) 10 hour rate (60A, 1.8V) 600Ah 5 hour rate (108A, 1.75V) 540Ah 1 hour rate (364A, 1.6V) 364Ah Internal Resistance 0.3mOhms Fully Charged battery 77oF(25oC) Self-Discharge 3% of capacity declined per month at 20oC(average) Operating Temperature Range Discharge -20~60oC Charge -10~60oC Storage -20~60oC o o 3000A(5s) Max. Discharge Current 77 F(25 C) Charge Methods: Constant Voltage Charge 77oF(25oC) Cycle use 2.35-2.45V Maximum charging current 120A Temperature compensation -5.0mV/oC Standby use 2.25-2.3V Temperature compensation -3.3mV/oC Discharge Constant Current (Amperes at 77oF25oC) End Point Volts/Cell 1.60V 1.65V 1.70V 1.75V 1.80V 10min 15min 30min 45min 1h 3h 5h 10h 1161 1101 1038 974 909 364 351 337 322 307 186 181 174 167 160 115 113 111 108 105 65 64 63 61 60 887 844 800 755 710 618 590 562 533 503 480 461 440 419 397 Discharge Constant Power (Watts at 77oF25oC) End Point Volts/Cell 1.60V 1.65V 1.70V 1.75V 1.80V 10min 15min 30min 45min 1h 2h 3h 5h 1911 1800 1688 1577 1467 710 680 649 617 583 483 472 460 446 418 358 349 340 330 309 225 222 218 214 211 1424 1123 1347 1067 1269 1009 1191 951 1112 892 905 864 820 776 731 (Note)The above characteristics data are average values obtained within three charge/discharge cycles not the mimimum values. page1 of 2 www.vision-batt.com Current Charged Volume O Discharge characteristic (25 C) Voltage CL600 (%) (xCA) Voltage(V) 2.0 2V600Ah Charge characteristic curve Constant voltage charge characteristic o (0.2CA,25 C) (V) 140 167A 108A 60A 120 0.25 100 0.20 80 1.6 600A 1200A 364A 1 2 3 5 20 30 10 min CHARGE VOLTAGE 2.25 0.15 60 0.10 40 0 CHARGED VOLUME 2.50 60 2 3 5 10 20 20 0.05 0 0 h 2.00 CHARGING CURRENT 1.75 0 Discharge time 2 4 6 8 10 12 14 16 18 20 Charging time (hours) Relationship between charging voltage and temperature Self-discharge characteristic 110 100 2.6 Capacity(%) Voltage (V) 90 2.5 CYC 2.4 LE U S TA N 2.3 SE D BY 80 70 60 USE 2.2 -10 0 10 20 30 o Ambient temperature( C) 40 40 50 0 2 6 8 10 12 14 Storage time: months 80 60 Testing conditions: floating voltage: 2.25 to 2.30V/Cell o o ambient temperature: 25 C(77 F) 18 20 80 60 40 40 20 20 0 5 10 Life(year) 100% D.O.D. 0 15 400 50% D.O.D. 800 1200 30% Depth of discharge 1600 2000 2400 Number of cycles(cycles) Temperature effects on float life Temperature effects on capacity 120 25 100 2.30V/Cell 0.1C Capacity (%) 20 Life(years) 16 100 Capacity(%) Capacity(%) 4 120 100 10 5 0.2C 0 .3 C 80 60 1 .0 C 40 2 .0 C 20 0 20 oC Cycle service life in relation to depth of discharge Life characteristics of standby use 120 0 30 oC 40 oC 50 10 20 30 40 0 50 -20 -10 Temperature( oC) THE INTERNATIONAL CERTIFICATION NETWORK ISO9001:2000 MH25860 0 10 20 Temperature( oC) 30 40 G4M19906-9202-E-16 www.vision-batt.com Shenzhen Center Power Tech. Co., Ltd. Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail: [email protected] Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2003-9) Page 2 of 2 50