Transcript
Clean Spa Technologies Owner’s Manual
Professional installation required. Please read instructions carefully before using spa. Patents Pending
Clean Spa Technologies
Please check to ensure you have received all parts for the assembly of this spa. If you find any part missing or damaged please call: 1-905-469-0505 Service Hours: Eastern Time 8:00am-5:00pm – Mon. – Fri.
INTRODUCTION
Congratulations on your purchase of a new Clean Spa Pedicure Spa. It is strongly recommended that you read and follow the instructions carefully prior to installing and using the spa. Once installed we are confident that you will be entirely satisfied with your decision in purchasing a Clean Spa product. Designed with the salon and client in mind, the Clean Spa sets a new standard in luxury, comfort and quality. From our ergonomically contoured design to the high quality components, the details illustrate our commitment in providing only the best. Thank you for choosing Clean Spa Technologies.
IIIMPORTANT SAFETY INSTRUCTIONS
Designed to give many years of use, your spa should be professionally installed to ensure that it is properly connected before use. The installation MUST comply with local, state, and national plumbing codes. Please contact the appropriate professionals when installing the spa.
Clean Spa Technologies 2172 Wyecroft Road, Unit 17 Oakville, Ontario, Canada L6L 6R1 Tel: (905) 469-0505 Fax: (905) 469-0293
Important Safety Instructions Instructions Pertaining to a Risk of Fire, Electric Shock, or Injury to Persons WARNING: When using the unit, basic precautions should always be followed, including the following: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. DANGER: To reduce the risk of injury, do not permit children to use this unit unless they are closely supervised at all times. 3. Use this unit only for its intended use as described in this manual. 4. Never drop or insert any object into any opening. 5. Do not use electrically connected devices such as television, radio, or speakers, lights, cooking devices, or telephones within 5 feet (1.5m) of the spa while it is being used. Lighting fixtures must not be located directly above or within 5 feet (1.5m) of the spa. 6. Do not operate this unit without the cover on the GeniJetTM motor. 7. The unit must be connected only to a supply circuit that is protected by a groundfault circuit-interrupter (GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the spa tub without the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this pedicure unit, disconnect the pedicure spa and have the problem corrected by a qualified service representative before resuming use.
INSTALLATION INSTRUCTIONS WARNING: When using electrical products, basic precautions should always be followed, including the following: 1. DANGER: RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a ground fault circuit-interrupter (GFCI). 2. Grounding is required. 3. Install to permit access for servicing. 4. Building materials and wiring should be routed away from the pump body or other heat-producing components of the unit. WARNING: The unit should be installed and serviced by qualified service personnel.
Identify the Parts of the Clean Spa
11
1. Chair body 2. Chair cushion and massager 3. Chair arm cushion 4. Massage controller 5. Light switch (optional) 6. On/off for GeniJetTM 7. Hot water supply 8. Cold Water supply 9. Foot rest adjustment button 10. Rear service area 11. Waste & Overflow control
12. Drain 13. Faucet & Hand spray 14. Adjustable foot cushion - standard 15. GeniJetTM System 16. Tub trim 17. Drain 18. Air control for GeniJetTM 19. Seat adjustment 20. Seat Swivel 21. Tub body 22. Electrical air switch
12
13
Figure 2 -top view
1
2 4 3
19
5
20 14 18
6 21
7
15
22 17
8 16 10
9
Figure 1 -front view
Figure 3 -side view
Specifications
Dimensions 52” L 31” W 52” H
Electrical Requirements 120 volt AC Requires dedicated separate circuit equipped with GFCI
Total Weight/ Floor Loading
Operating Gallonage
Product Weight
155 lbs
4.5
125 lbs
52"
1-1/4" drain 1-1/4" drain
26"
24"
49"
31"
POWER AND PLUMBING REQUIREMENTS Power source 120 VAC, 60HZ with Ground Fault Circuit Interrupter (GFCI) Class AType Water Source ½ inch fitting hot and cold Drain source 1 ½ inch drain WARNING: You must have a qualified, licensed electrician connect this spa. Failure to do so may result in serious injury and/or death due to electrical shock and may void your warranty.
PLUMBING INSTALLATION NOTES
Common 1. Electric source 120 VAC 60 HZ, Ground Fault Circuit Interrupter (GFCI) Class A-Type supplied by electrician. 2. Water source 31" Hot: ½ inch (fitting included) Cold: ½ inch (fitting included) 3. The Spa is self-supporting provided Spa is mounted level. 4. Bottom of “P” trap is below floor line 5”(12.7cm) “P” trap is supplied by plumber.
31"
26"
52"
31"
DRAIN CONFIGURATION
INSTALLATION INSTRUCTIONS NOTE: before installation, make sure the pedicure spa unit sits level. • “P” trap to be supplied by plumber. • (Fig 1) Wall Drain (Note: bottom of “P” trap is approximately 2” below the floor surface), when using standard “P” trap. • Connect “P” trap to Drain Pipe marked “Drain” to the Spa. • Connect HOT water supply to flexible pipe marked “Hot Water” to the Spa. • Connect COLD water supply to flexible pipe marked “Cold Water” to the Spa.
INSTRUCTIONS (How to install the Chair to the Base) Note: 2-person installation is recommended. Models Pisces, Sunshine, Mini-Rainbow, The-Wave (by Modern) 1. Place the spa base in its permanent position (base must be level on the floor). 2. Place the chair on top of base align the 4 base screws on the 4 pre-drilled holes on base and make sure the lever for reclining the chair is on the right side of the chair. The lever for the slider is to be on the left. 3. Place the washers and fasten by tightening the nuts securely onto the base. Important: (final tightening with wrench is recommended) Help Line please call: 1-905-469-0505 Note: If using in floor drain system disconnect factory supplied “P” trap and hook directly to plumbed “P” trap using standard parts.
Operating the Clean-Spa
Relaxor Personal Massage System
Getting started
Operating Instructions 1. Join the plug from the cable on the COMMAND WAND to the matching receptacle, which exits from your Clean Spa Massage Chair. 2. Leave the POWER switch on the COMMAND WAND in the OFF position. If your system has HEAT, put the RELAX-BOTH-HEAT switch in the relax position. 3. Plug the cord from the A.C. ADAPTER or TRANSFORMER into the remaining receptacle in the back of Spa air switch box (marked CHAIR). 4. Sit in your massage chair and start to familiarize yourself with the System operation. 5. Place the Relaxor switch in the ON position. Slide the INTENSITY knob all the way to the (-) low. Turn on the POWER switch. You can now manually position the massage action to any three-body locations. Each time you press the SELECT button you will move the massage action one position up, or down, as indicated by the green lights on the COMMAND WAND. Now, gradually slide the intensity knob toward (+) high to determine the best intensity for you. Reset INTENSITY in following steps. 6. Set Relaxor switch to wave. Slowly move the SPEED knob up and down to fine the save actions you like best. The green lights on the COMMAND WAND will flash in sequential order from top to bottom, then back up to top continuously repeating this cycle. The lights show the activation of the corresponding pulsing transducers and you will feel a gentle massaging action at the positions shown by the lights 7. If your system has HEAT, move the RELAXBOTH-HEAT switch to HEAT, and after a short warm-up time, enjoy comforting warmth in the lower back (lumbar)area. Now move the switch to BOTH and indulge in the ultimate combination of massage and heat. You have now completed all of the operational choices provided on the COMMAND WAND. Select any combination of the above-described modes, intensities and heat. The Massage System will automatically shut down after approximately 15 minutes of operation. To restart, simply move the POWER switch to OFF then back to ON. Now close your eyes and enjoy your Clean Spa Massage Chair Note: it is normal for the COMMAND WAND to become warm during use. If your Clean Spa system does not operate properly, or you need assistance for any reason, call Clean Spa Technologies.
1.
Turn drain handle; check that drain valve is closed. 2. Open the faucet handle and fill tub with water until the water level is 1” above jets. 3. Press air button switch jetting on to start the GeniJetsTM. 4. Adjust the air control manifold. At no time must the pump be turned on when the system is dry, as damage may occur. Such damage is not covered by warranty. While the jet action is in operation, do not use an excessive amount of soap, bath oils or detergent, as high action turbulence often causes foaming.
Shutting down 1. 2. 3.
Push in air button switch and turn jets off. Turn drain handle and check drain valve is open. Clean Tub.
User Maintenance instructions The GeniJetTM must be cleaned between usages. The following procedure is suggested: Spray and clean tub and GeniJetsTM using Hydrogen Peroxide 3 to 11% then wipe down using freshly washed towel. Do not use ‘Bleach’ or products containing chlorine.
Stains For stubborn stains start with a liquid detergent, if this does not work, try a mild powder detergent such as Spic and Span, which also works well for removing heavy soap film. Cleaning pads made of nylon; saran or polyethylene containing no abrasives may be used. DO NOT USE ABRASIVE SCOURING POWDERS OR METAL SCOURING PADS as they can permanently damage the finish. A mild abrasive action can be accomplished with an automotive type of rubbing compound. There are several types available, both coarse and fine. The fine ones take a little longer to remove a stain, but they do not dull the surfaces as much. Should your stain removal result in a dull area; the shine can be restored with an automotive polish and wax, such as Turtle Wax.
Things to Avoid Sand and grit. Dropped tools. Acetone on any acrylic surface. Bleach.
Damage Should your unit suffer accidental damage or require servicing, a qualified repairperson must perform it. Consult your plumber, wholesaler or Clean Spa Representative.
Precautions and Maintenance 1. 2. 3. 4.
Disconnect power before any maintenance is performed. Do not use heavy force on controller parts and accessories. Water level must be 1” above the jets. If a spill of nail polish remover occurs, immediately wash out with clean water. Never attempt to clean the chair or tub with nail polish remover. (Spill may void the warranty) 5. Never attempt to turn on the power switch without water in the tub. (Running dry may void the warranty.) 6. Massage controller and any electrical devices must stay away from the water in Tub area. 7. Tell each and every customer to use care and caution when using the foot spa. 8. Check the water temperature before every use – hot water is dangerous. 9. All units are factory-tested for operation and leaks 10. The unit must not be operated unless it is properly connected through a Ground Fault Circuit Interrupter GFCI (Class A type). 11. Tampering with any devices is prohibited. 12. Do no operate GeniJetTM system without front(s) cover on.
WARNING YOU MUST HAVE A QUALIFIED, LICENSED ELECTRICIAN CONNECT THIS SPA SAFELY. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY AND/OR DEATH DUE TO ELECTRICAL SHOCK. Specifications subject to change without notice. WARNING DO NOT USE IF you are diabetic, have poor circulation, or if any area of your feet or legs is inflamed or has an open sore. Consult a physician before using if you have any kind of fungal infection, swelling, fracture or persistent pain.
LIMITED WARRANTY Clean Spa Technologies warrants this product against defects in material or workmanship for a period of one (1) year from date of purchase as follows: 1. LABOR: If this Product is determined to be defective, Clean Spa Technologies will repair or replace (at our sole discretion) the Product at no charge. After the warranty period, you must pay for all labor charges. 2. PARTS: In addition, Clean Spa Technologies will supply, at no charge new or rebuilt replacements in exchange for defective parts for a period of one (1) year. After the warranty period, you must pay for all parts. 3. MOTOR (GeniJetTM): Defective parts and labor are warranted for one (1) year. After the warranty period, you must pay for all costs. No tampering, no bleach. No abuse. Proof of purchase of sale or receipted invoice must be presented to obtain warranty service. You must take the Product, or deliver the Product freight prepaid to Clean Spa Technologies or arrange through your representative.
This warranty does not cover customer installation costs or set-up. Damage due to improper use. Improper maintenance. Does not cover loss of business under any circumstance. This warranty is null and void if the Product is removed from its place of initial installation. Is not installed in accordance with federal, provincial or municipal codes and ordinances. This warranty does not apply if the Product has been subject to misapplication, improper installation or maintenance, negligence or other circumstances beyond the control of Clean Spa Technologies.
© 2007 Clean Spa Technologies. All Rights Reserved.