Click Here For Instructions For Removing And Replacing The Combustion Blower On Your Pellet Grill.

   EMBED


Share

Transcript

Pellet Stoves Wood Stoves Multi-Fuel Stoves Pellet Grills P.O. Box 206 Monroe, VA 24574 www.heatredefined.com Phone: (800) 516-3636 Fax: (434) 929-4810 Combustion Blower Removal/Replacement  WARNING: BE SURE TO READ YOUR OWNER’S MANUAL BEFORE ASSEMBLING OR OPERATING YOUR GRILL. ALWAYS FOLLOW ALL CODES. Be sure the unit is unplugged and cooled before performing any maintenance/component replacement.   To remove or replace the combustion blower, you will need a 5/16” socket or open‐ended  wrench.  Remove the cover panel (see Cover Panel Removal Instructions if necessary) ‐ to do this  you will need to remove the six 5/16” screws.    Once you have the cover panel off, loosen the two 5/16” screws that hold the blower in place  (and that attach the ground wire to the grill, see above).  Cut the wire tie holding the two  orange wires to the combustion blower, then disconnect the wires from the blower.  Slide  the blower up and out of the grill.    To install the new blower, slide the new blower in the same way you removed the old one.   (The arrows on the blower should be pointing in towards the burn pot).  Reconnect the  wires to the terminals on the blower and, using a zip tie, attach the wires to the top right of  the combustion blower, as shown above.  Tighten the two screws that were previously  loosened and reinstall the cover panel.