Transcript
WXS2021 Appliance Specifications - Wood-Burning Stove
Description
Ship. Weight
Ship. Volume
F1775
WXS2021 Wood-Burning Stove
310 lb.
23 cu. ft.
Listing
Notes
Cat. No.
Notes: • . Dimensions shown are approximations only (+/- 1/4”) • Diagrams, illustrations and photographs are not to scale – consult installation instructions. Product designs, materials, dimensions, specifications, colors and prices are subject to change or discontinuance without notice. • Approved for residential and manufactured home installations. • Optional Kits Available: Blower and Outside Air Kit u Square-foot heating capacities and burn times are approximations only. Actual performance may vary depending upon home design and insulation, ceiling heights, climate, condition and type of wood used, appliance location, burn rate, accessories chosen, chimney installation and how the appliance is operated.
Specifications
Product Reference Information
Stove Pipe Diameter Single Wall or Double Wall
6” (152 mm)
Log Length
20” Max. (508 mm Max.)
Firebox
Volume = 2.1 cu. ft.
Cord Wood: u
76,000 BTUs/hr.
Maximum Burn Times u
7-9 hours
Heating Capacity u
1,200 to 2,000 sq. ft.
EPA Phase II and Washington State Approved
The WXS2021 woodstove is safety listed with the following agency: • Intertek, Tested to UL 1482, ULC S627
25-7/8” (657mm) Optional Blower 3-11/16” (94mm)
5-3/4” (146mm)
23-3/8” (594mm) 26-3/16” (665mm)
4002589
TOP VIEW
23-3/8” (584mm)
1-5/8” (41mm)
Dimensions
5-3/4” (146mm)
9” (229mm) 18-3/4” (476mm) 30-5/16” (770mm) 22-1/4” (565mm) 25-7/8” (657mm)
20” (508mm)
RIGHT SIDE VIEW
P/N 900168-01, REV. NC, 12/2013
21” (533mm)
FRONT VIEW
Page 1 of 2
WXS2021 Clearances Corner Installation
Parallel Installation
Parallel Installation Combustible Wall
Combustible Wall B A
Combustible Wall
L
C D H
Stove
I
T
F G
G F
M
Floor Protection
K
E†
USA
6” Ø Flue Collar
E†
Floor Protection
J
Top View
Stove
Stove
USA
K
I
E
Canada † See note 8
Side View
Top View
USA - inches (millimeters) PIPE
INSTALLATION
A (3) B (1)
C (3)
D (1)
H (2)
I (6)
E (8)
F (1)
G (3)
Single Wall Residential
14-1/4 11-5/8 22-1/2 13-3/16 8 (362) (295) (572) (335) (200)
9 (229)
Double Wall Residential or Mobile Home
12 9-3/8 (305) (238)
19 (483)
9-5/8
8 (245) (200)
J (2)
K (7)
L (5)
18 37-7/16 49 (457) (951) (1245)
34-3/4 (883)
16 (406)
0 (0)
96 61-1/2 (2438) (1562)
6 (152)
15 37-7/16 46-3/4 (381) (951) (1188)
34-3/4 (883)
16 (406)
0 (0)
96 57-5/16 (2438) (1456)
PIPE INSTALLATION
A (3) B (1)
C (3)
D (1)
Single Wall Residential
14-1/4 11-5/8 22-1/2 13-3/16 8 9 (362) (295) (572) (335) (200) (229)
F (1)
G (3)
18 47-7/16 51 (457) (1205) (1295)
J (2)
K (7)
L (5)
40-7/8 (1038)
18 (450)
8 96 63-1/2 (200) (2438) (1613)
Double Wall Residential or Mobile Home
12 9-3/8 (305) (238)
15 47-7/16 48-3/4 (381) (1205) (1238)
40-7/8 (1038)
18 (450)
8 96 59-5/16 (200) (2438) (1507)
CANADA - inches (millimeters)
Footnotes: 1- These dimensions to the stove body are for reference only. Actual distances should be measured from the stove’s flue collar. 2- Minimum noncombustible hearth pad dimensions. 3- Clearances to connector pipe shall be measured from the flue collar of the stove.
Printed in U.S.A. © 2013 IHP LLC P/N 900168-01, REV. NC, 12/2013
Floor Protection
19 9-5/8 (483) (245)
E (8)
8 6 (200) (152)
H (2)
5- In corner applications, when installed at minimum back wall clearances, the required floor protection is dimensioned off the back plane of the stove, therefore the floor protection required off the back corners (at a 45 degree angle) only needs to extend to the wall. This situation will only occur in CANADA installations.
I (6)
M
M
T (6)
T (6)
6- Reference dimension only, to assist in planning the installation. 7- Measured from front of floor protection to the front of firebox. 8- USA=8” (200mm) from door opening, Canada=8” (200mm) from sides and back of unit.
Page 2 of 2