Transcript
CLS Manuals
CLS Zense INTRODUCTION The CLS Zense is a DMX controller specially designed for LED applications. It supports up to 5 colour control with or without a master channel. Besides the DMX, the CLS Zense is also able to directly drive voltage-controlled LED products, such as Colourcove X-bright, Manon single colour and RGB, Safestairs etc. The CLS Zense is designed to fit in the most common wall mount fittings. This makes the CLS Zense very easy to install. The universal connection possibilities make it perfect for every installation. Because the CLS Zense uses Capsense technology, the surface is totally flat. Included items The CLS Zense is shipped in one package containing the following items: • 1 x CLS Zense • 1 x manual • 1 x black frame • 1 x white frame • 1 x power supply & 4 plugs (VDE + UL & PSE + SAA + BS) • 1 x RJ45 to PWR cable • 1 x RJ45 to XLR cable • 1 x 3-way connection block RJ45 • 1 x UTP-CAT5 cable, 2mtr Note: It is important to read this manual before you install this product.
SAFETY INFORMATION Warning! This product is for professional use only. Read this manual before powering up or installing the CLS Zense. Follow the instructions listed below and observe all warnings in this manual. Protection from electric shock • Disconnect the power supply from AC power before installing, dismounting or maintaining the unit. • Make sure all connectors are connected properly. • Use only a source of AC power that complies with local building and electrical codes. • Do not expose the unit to rain or moisture. • Refer all service to a qualified technician.
CLS Zense
Protection from burns and fire • Do not install the CLS Zense near a heat source. • Do not install the CLS Zense in a corrosive, flammable or explosive area. • Do not modify the CLS Zense, or install other than genuine parts. • Do not operate the unit if the ambient temperature exceeds 40 ºC. • Operate in a well ventilated area Protection from injury due to falls • Verify that all covers and mounting hardware are securely fastened. • Block the access below the work area whenever installing or removing the unit.
version 2.1 August 2010
-1-
www.cls-led.com
-2-
www.cls-led.com
CLS manuals
CLS Zense LAY-OUT DESCRIPTION The Zense is used with the latest Capsense technology. The buttons do not have te be pressed. Just touching the buttons or slider is enough to control the Zense. B2 I2
B1 I1
L1-10
S1
INSTALLATION
NG
ATTENTION! Before installation, determine exactly how the system needs to be controlled with the Zense. Is the direct drive system used or DMX or even both. There are some differences when using direct drive, DMX or both.
NG
ATTENTION! Don't use the bottom and upper mounting hole to install the CLS Zense! Only use the left and right mounting holes shown in the drawing. Keep the connector at the bottom of the CLS Zense!
I RN
A W
I RN
A W I4 B4
I3 B3
B1
Off: Brightness:
hold ± 3 seconds to switch off. touch for brightness control.
B2
Colour:
touch for colour control.
B3
Saturation: Speed: Saturation:
touch for saturation control, in colour mode. touch for speed control, in program mode. hold ± 3 seconds for saturation control, in program mode.
B4
Program:
touch for program control.
S1 Slider:
touch the desired colour on the slider. Slide your finger over the circle to fine-tune the selected colour. Clockwise to increase, counterclockwise to decrease.
The indication LEDs will indicate where the Zense is in it’s menu and what value is selected. The Zense uses constant and flashing LEDs to indicate several states. I1
Constant:
brightness control.
I2
Constant:
colour control, Zense is in colour mode.
I3
Constant:
saturation control, when colour mode.
Constant:
speed control, when program mode.
Flashing:
saturation control, when program mode.
I4
Constant:
program control, Zense is in Pogram mode.
L1-10 Constant:
Wall installation
circle of LEDs indicate the selected value.
-3-
Clear plastic screw
Clear plastic front cover
Display cover
PCB
Connector
Maximum fixtures on the CLS Zense • CLS Covelight Superior RGB 150 LEDs • CLS Covelight Superior RGB 300 LEDs • CLS Colourcove X Bright • CLS RGB Quentin LED-pipe, 34,5 cm • CLS RGB Quentin LED-pipe, 101 cm • CLS RGB LED-pipe, 34,5 cm • CLS RGB LED-pipe, 101 cm • CLS Manon RGB V2-1, 12,5 cm • CLS Manon RGB V2-2, 26,5 cm • CLS Manon RGB V2-3, 50,5 cm
Frame
Mounting plate
Wall socket
Amount 10 metres 5 metres 10 metres 18 pipes 6 pipes 18 pipes 6 pipes 48 pieces 24 pieces 12 pieces
-4-
www.cls-led.com
CLS manuals
CLS Zense
Direct drive system The CLS Zense can be used to directly drive voltage controlled LED products. The CLS Zense is fitted with a 6-pole universal connector to make installation of many products possible. The power supply needed for the voltage-controlled LED product is also used to power the CLS Zense. Therefore, the supplied power supply is not needed.
DMX CONTROL SYSTEM The CLS Zense is able to control light fixtures with DMX. It sends out the colour and brightness settings for a LED fixture. It can control single colour, RGB, RGBA, RGBW, RGBAW products. It also supports a optional master channel. A master channel is used by several products to control the brightness separately from the colour control. This enables brightness control without changing the colour setting. The master channel is usually located behind or before the colour channels. The Zense supports both ways and can be configured.
Example: The CLS Zense with RGB products (e.g. the CLS Colourcove X Bright). The RGB fixture works with 24 VDC. The power supply for the RGB fixture is connected to the [+] and [-] contacts of the CLS Zense. The RGB fixture is connected to the [R], [G], [B] and [C] contacts of the CLS Zense, as shown in the drawing below.
The connection of the DMX is according to the CLS standard and also used for the CLS LON. This way the CLS Zense can be directly connected in the CLS LON system. The CLS Zense is powered from the UTP cable and sends out the DMX over the same UTP cable. For other applications a splitter block with converter cables are added to connect the supplied power supply and standard DMX cable to the controller. The CLS Zense can control multiple fixtures via DMX. All these fixtures should be set to DMX address 1. Example: The CLS Zense with the CLS LON system. The CLS Zense can be connected to the last CLS LON or a free output on the CLS LON connection box. Standard straight CAT5 UTP cabling can be used. CAT5 UTP cable
max. 15 m
1
CLS Zense
RGB fixture
Example: The CLS Zense with single colour products (e.g. the CLS Safestairs). The single colour fixture works with 12 VDC. The power supply for the single colour fixture is connected to the [+] and [-] contacts of the CLS Zense. The single colour fixture is connected to the [R] and [C] contacts of the CLS Zense.
2
3
DMX
4 power
CLS LON connectionbox CLS LON
CLS Zense
With CLS LON connectionbox. CAT5 UTP cable max. 15 m
1
2
3
DMX
CLS Zense
4 power
Single colour fixture CLS LON
CLS LON connectionbox
The maximum power that can be driven by the CLS Zense depends on the voltage of the product. A simple formula can be used to calculate the maximum power: 4A x Voltage product = Power
-5-
CLS Zense
-6-
www.cls-led.com
CLS manuals
CLS Zense Example: The CLS Zense with other DMX fixtures (e.g. the CLS LED PAR RGB). The CLS Zense can be connected with the supplied connector kit. Standard straight CAT5 UTP cabling can be used between the splitter and the CLS Zense. CAT5 UTP cable max. 15 m
RJ45 to PWR cable
RJ45 Splitter
Configuration After the installation is done the CLS Zense must be configured.
Power supply
Step 1 To access the configuration mode place your finger on the Program button while tapping three times on the brightness button within 3 seconds.
RJ45 to XLR cable
3x
3x
When configuration mode is entered LED [I2] starts flashing 3x DMX fixture CLS Zense
Combined system It is also possible to use the DMX and Direct drive together. However, this is only possible for SINGLE colour (1 channel DMX) and RGB (3 channel or with master 4 channels DMX). The CLS Zense uses the power that is connected to power the voltage-controlled LED product. The same colour and brightness setting is sent out via DMX. This makes it possible to control the colour of the RGB fixture and also of the DMX fixture. Be aware that not all LEDs are exactly the same, it is possible that there is a slight difference in colour. Direct control DMX controll
1 Channel √ √
3 Channels 4 Channels 5 Channels Master √ √ √ √ √
As described in the table above the direct drive system allows a maximum of three channel control. • 1 Channel can be used to control single colour LED products. The Zense only uses the brightness control. • 3 Channels can be used for LED products with RGB. The colours that are controlled are the same for direct drive as for DMX, however the direct drive can support only up to 3 channels. CAT5 UTP cable max. 15 m
RJ45 Splitter
RJ45 to XLR cable
DMX fixture
Step 2 By placing your finger on the colour button you are able to configure the channels of the CLS Zense. Move your finger over the slider to adjust the setting. LED [I2] is flashing LED L1 on: Single colour LED L1-3 on: RGB LED L1-4 on: RGBA or RGBW LED L1-5 on: RGBAW
(Direct drive and DMX) (Direct drive and DMX) (DMX only!) (DMX only!)
Step 3 By placing your finger on the Brightness button, you are able to configure the master channel of the CLS Zense. Move your finger over the slider to adjust the setting. LED [I1] is flashing LED [L1]: Master ch. Off LED [L2]: Master ch. Behind (master is added behind colour channels) LED [L3]: Master ch. Before (master is added before colour channels) The master function only applies for DMX!
CLS Zense
RGB fixture
-7-
-8-
www.cls-led.com
3x
CLS manuals
CLS Zense Step 4 Save the configuration, place and hold your finger on the Saturation button until the LEDs stop flashing. The CLS Zense always returns to Colour control. Cancel the changes, place and hold your finger on the Program button until the LEDs stop flashing. The CLS Zense always returns to Colour control. The Zense is now configured and ready to be used! operating Switch on The Zense is switched on by touching any button or the slider. The Zense will return where it was turned off. This way it is not necessary to select your favourite settings every time the Zense is switched on. Switch off Holding the brightness button for ± 3 seconds will switch off the Zense. The controlled LED products are switched off. For DMX the all channels are set to zero and the direct drive output is switched off. Brightness Touching the brightness button will set the Zense to brightness control. Indication LED I1 is on. LED I2 or I4 is still on, indicating that the Zense is in colour or program mode. The slider can be used to adjust the brightness. The LEDs L1-L10 indicate the brightness that is selected on a scale from 5-100%.
Colour Touching the colour button will set the Zense to colour control. Indication LED I2 is on. The slider can now be used to scroll through the colour palette. The image of the colour palette under the slider is equal to the selected colour. The LEDs L1-L10 give an indication of the selected colour.
-9-
Program control Touching the program button will set the Zense to program control. Indication LED I4 is on. The slider can now be used to select a program. The Zense is pre-programmed with 10 different colour programmes. Program 1: Program 2: Program 3: Program 4: Program 5: Program 6: Program 7: Program 8: Program 9: Program 10:
Red Green Green Blue Blue Red Yellow Cyan Cyan Magenta Magenta Yellow Orange Yellow Pink Magenta Rainbow (red-green-blue) Rainbow (red-blue-green)
(Fade) (Fade) (Fade) (Fade) (Fade) (Fade) (Fade) (Fade) (Fade) (Fade)
The LEDs L1-L10 indicate which program is selected. L1 stands for program 1, L2 for program 2 and so on. Saturation Colour mode: touching the saturation button will set the Zense to saturation control when the Zense is in colour mode. LED I3 is on. LED I2 is also on, indicating that the Zense is in colour mode. Holding the saturation button for ±3 seconds will set the saturation to 0%. Program mode:
holding the saturation button for ± 3 seconds will set the Zense to saturation control when the Zense is in colour mode. LED I3 is flashing. LED I2 is also on, indicating that the Zense is in colour mode.
The slider can now be used to adjust the saturation. The LEDs L1-L10 indicate the saturation that is selected on a scale from 0-100%. The saturation is also used to control the fourth and fifth channel, if configured. The colour control will as described in the table below. Zense configuration 1 channel 3 channels
Fourth channel 0-100%
-
4 channels
0-50%
5 channels
0-60%
Fifth channel 0-100%
-
20 – 80%
- 10 -
Saturation all channels
-
0 – 100% 50-100% 80 – 100%
www.cls-led.com
CLS manuals
CLS Zense Speed control Touching the saturation button will set the Zense to speed control, if the Zense is in program mode. Indication LED I3 is on. LED I4 is also on, indicating that the Zense is in program mode. The slider can now be used to adjust the speed of the programs. The LEDs L1-L10 indicate the selected speed on a scale from 1 hour to 10 seconds.
Full white Holding the colour button for ± 3 seconds will set the saturation and brightness to 100%. This will set all lights to maximum light output. This feature can be used when there is a need for high light output. When button colour or program is touched the Zense will return to the old setting.
Technical Specifications Input voltage: Power consumption: Direct drive current: Housing: IP value: Measurements: Weight: Operating ambient temperature:
12 - 24 VDC max. 2 Watt max. 4 A ABS and Polycarbonate IP20 82 x 82 x 30 mm (hxwxd) 105 gr -10 ºC till +40 ºC
List of symbols Protection class One, two or three
Cable length Maximum cable attached on the fixture in centimeters
200 cm
MEASUREMENTS
Application area Indoor or outdoor
Driver
Driver
Incl.
Excl.
Weight In gram/kilogram
Application area Floor, wall or ceiling
Swivel Fixture is horizontally rotatable, indicated in degrees
82 mm 350°
30 mm
15kg/cm2
10.000 h
Multiple connection Possiblities on a fixture
pinning dmx output
6 cm
PIN colour function 1 Orange/white Not connected 2 Orange Not connected 3 Green/White Not connected 4 Blue DMX data 5 Blue/White DMX data + 6 Green Not connected 7 Brown/White PWR + 8 Brown PWR - (DMX com)
- 11 -
4 cm
4 cm
Pressure Maximum pressure on the fixture per kg/cm2 Lifespan Of the light source in hours
Swivel Fixture is vertically rotatable, indicated in degrees
350º
82 mm
Driver Inclusive or exclusive
Installation depth In centimeters
20 mm
4 cm
Curve Minimal bending curve in centimeters LED pitch Pitch between the LEDs in millimeters
Mounting hole In centimeters 4 cm
4x4 cm
2007 CLS-LED BV. All rights reserved. Information is subject to change without notice. CLS-LED BV and all affiliated companies disclaim liability for injury, damage direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this manual. No part of this manual may be reproduced, in any form or by any means, without permission in writing from CLS-LED BV. Other legal information can be found in our General conditions to be found on the back of your CLS-LED BV invoice or on our website www.cls-led.com/conditions.pdf
- 12 -
www.cls-led.com