SENSOR SWITCH PIR AND PDT CEILING MOUNT OCCUPANCY SENSORS CM SERIES
DESCRIPTION
The CM Series occupancy sensor offers amazing peformance and sensitivity to small motions. There are variety of model options to fit the applcation needs. The CM 9 models offers standard range PIR sensor for smaller rooms and the CM 10 models provide extended range for larger spaces. The CM PDT models offers dual technolgoy PIR with Microphonics for excellent detection. The CMR line voltage models are economical solution for automatic lighting control with no power pack needed. The CM series is light weight and ceiling mounted with 360 degree coverage pattern.
FEATURES • • • • • • •
100% digital PIR detection with excellent RF immunity Push-button programmable User adjustable time delays (30 sec to 20 min) No field calibration or sensitivity adjustments required Convenient test mode 100 hr lamp burn-in timer Green LED indicator
CM9
SPECIFICATIONS Supply Voltage CM CMR
360° Passive Infrared (PIR) Dual Technology (PIR and Microphonics) Operating Temperature 14 to 160°F (-10 to 71°C) Operating Humidity 20-90% non-condensing Mounting Ceiling mount Dimensions 4.55"Ø (11.56 cm), 1.55" (3.94 cm) deep Approvals UL, cUL (E167435) Weight 0.38 lb (0.17 kg) Warranty 5 year limited
4mA, 16mA w/R option 50/60 Hz 1/4 HP Sinks <20mA 500 sq. ft 1000 sq. ft 2000 sq. ft. 2500 sq. ft,
LIGHTING CONTROLS
Supply Current CMx Frequency Motor Load CMRx Dimming Load Coverage CMx-9 CMx-PDT-9 CMx-10 CMx-PDT-10
11
Coverage Pattern Sensor Type CMx CMx-PDT
12-24 VAC/VDC 800/1200/ 1500 W @ 120/277/347 VAC
INSTALLATION PUSH BUTTON FOR TIMER PROGRAMMING
PROGRAMMING INSTRUCTIONS 1. Press button twice for function 2, occupancy time delay. 2. LED will flash back the selected function's current setting (5 flashes for 10 minutes time delay). 3. Press button the number of times indicated in Occupancy Time Delay table below to change. 4. To exit the current setting, wait for LED flsh dequence to repeat 3 times then return to step 1.
March 2014
WE MAKE IT EASY.
kele.com
888-397-5353 USA
633
NEW!
LIGHTING CONTROLS
SENSOR SWITCH PIR AND PDT CEILING MOUNT OCCUPANCY SENSORS CM SERIES WIRING STANDARD WIRING
- Power Input (12-24 VAC/VDC) RED BLACK - Common WHITE - Occupancy State (high VDC for occupied)
PHOTOCELL/DIMMING OPTIONS
POWER PACK
RED WHT BLK
(-)
BLUE - Direct output to power pack for providing photocell control and/or secondary dim time out. Output is high VDC with occupancy & low light. Output also held high during secondary dim time out. For multi-level control, use two power packs and connect White wire to primary load and Blue to daylight load. VIOLET w/ WHITE STRIPE - Connect to 0-10 VDC control wire (typically Violet) from 0-10 VDC dimmable ballast GRAY from BALLAST - Connect to sensor Black wire
11
(PP20)
VIO w/ WHT STRIPE (+)
Photocell / Dimming Options
Relay Option
CM MODEL
SENSORS IN PARALLEL Sensors may be wired in parallel; however, the maximum load ratings stay the same. Do not wire sensors with Photocell and dimming option in parallel. H
HOT BLK
BLK
BLK
BLK
BLK
BLK
WHT
WHT
N
SWITCH LOAD
WHT
LIGHITING CONTROLS
VIO (+)
N
LOAD
GRY (-)
Dimming Options
N
CMR MODEL
ORDERING INFORMATION MODEL CM-10 CM-9 CM-PDT-10 CM-PDT-9 CMR-10 CMR-9 CMR-PDT-10 CMR-PDT-9
DESCRIPTION Extended Range 360 Degree Sensor-Ceiling Mount, Low Voltage, PIR Standard Range 360 Degree Sensor-Ceiling Mount, Low Voltage, PIR Extended Range 360 Degree Sensor-Ceiling Mount, Low Voltage, PDT Standard Range 360 Degree Sensor-Ceiling Mount, Low Voltage, PDT Extended Range 360 Degree Sensor-Ceiling Mount, Line Voltage, PIR Standard Range 360 Degree Sensor-Ceiling Mount, Line Voltage, PIR Extended Range 360 Degree Sensor-Ceiling Mount, Line Voltage, PDT Standard Range 360 Degree Sensor-Ceiling Mount, Line Voltage, PDT
Note: Call Kele for models with low voltage relay, photocell, dimming, and low temperature options availabilty.
PP20
634
888-397-5353 USA