CLAMP METERS
Clamp meters
CMP-400, CMP-401
30mm
Index: WMXXCMP400 (CMP-400) WMXXCMP401 (CMP-401)
Clamp meter
Additional functions of the meter:
CMP-1006
Safe, insulated measurement clamp. Automatic selection of ranges with the capability of switching over to the manual 34mm
Index: WMXXCMP1006
selection mode. "HOLD" - freezing the result on the display. Backlit LCD. "DC ZERO" - relative measurement mode for direct current - capability of zeroing
Measurement of alternating voltage and direct voltage
the instrument at any moment and returning to the absolute measurement mode.
Resolution
CAT III
Display range 400.0 mV
0.1 mV
600V
4.000 V
0.001 V
40.00 V
0.01 V
400.0 V
0.1 V
600.0 V
1V
IP 40
Accuracy CMP-400 (AC)
Capturing minimal and maximal values.
CMP-401 (AC)
CMP-400, -401 (DC)
±(1.5%m.v.+30digits) ±(1.5%m.v.+30digits) ±(0.8%m.v.+2digits)
CAT III
Indication of range exceedance. Auto power-off.
600V ±(1.8% m.v. + 8 digits) ±(1.5%m.v.+5digits) ±(1.5%m.v.+2digits) ±(2.5% m.v. + 8 digits) ±(2% m.v. + 5 digits)
±(2% m.v. + 2 digits)
Measurement of direct and alternating current (TRUE RMS)
IP 40
Display range
Accuracy (DC)
Resolution
· frequency range: 50...400 Hz 0...659.9A
Measurement of alternating current
Standard accessories of the meters: - Test leads (2 pcs) - K type temperature probe - 9 V battery - Case
Display range
Resolution
4.000 A
0.001 A
±(2.5% m.v. + 12 digits)
no range
40.00 A
0.01 A
±(2.5% m.v. + 8 digits)
±(2.5% m.v. + 8 digits)
400.0 A
0.1 A
±(2.8% m.v. + 8 digits)
±(2.8% m.v. + 5 digits)
Accuracy CMP-400
Accuracy CMP-401
· frequency range: 50Hz...60Hz
WAPRZCMP1 WASONTEMK
Measurements: - measurement of alternating current up to 400 A, - measurement of direct current up to 400 A (CMP-401), - measurement of direct and alternating voltage up to 600 V, - measurement of resistance and connection continuity test with acoustic signalling of circuit continuity (for the value of resistance smaller than 50 Ω), - measurement of temperature (Fahrenheit or Celsius), - measurement of frequency, - measurement of capacity (CMP-401 only), - diode test.
Resolution
Accuracy
40.00 A
0.01 A
±(2.5% m.v. + 5 digits)
400.0 A
0.1 A
±(2.8% m.v. + 5 digits)
Measurement of resistance Display range
Resolution
Accuracy
400.0 Ω
0.1 Ω
±(1.0% m.v. + 4 digits)
4.000 kΩ
0.001kΩ
40.00 kΩ
0.01 kΩ
400.0 kΩ
0.1 kΩ
4.000 MΩ
0.001 MΩ
±(2.5% m.v. + 3 digits)
40.00 MΩ
0.01 MΩ
±(3.5% m.v. + 5 digits)
±(1.5% m.v. + 2 digits)
- Test leads (2 pcs) - K type thermocouple - 9 V battery - Case
WAPRZCMP1 WASONTEMK
Measurements: - measurement of alternating (TRUE RMS) and direct current up to 1000 A, - measurement of initialmotor starting current (very high sampling frequency - INRUSH function). - measurement of direct and alternating (TRUE RMS) voltage up to 600 V, - measurement of resistance and connection continuity test with acoustic signalling of circuit continuity (for the value of resistance smaller than 40 Ω), - measurement of temperature (Fahrenheit or Celsius), - measurement of frequency, - measurement of duty cycle, - diode test.
Non-contact neon lamp.
Automatic selection of ranges with the capability of switching over to the manual selection mode. "HOLD" function, allowing for freezing the result on the display.
Leakage current clamp meter
CMP-200
mm
30
Additional functions of the meter: 3½ digits LCD (max. 1999). Internal diameter of clamp approx. 30 mm (1.2"). "HOLD" function, allowing for freezing the result on the display.
Indication of range overflow.
"MAX" function, allowing for capturing maximal values.
CAT II
Automatic power-off of an unused instrument.
600V
Reinforced, impact resistant enclosure.
Other technical specifications: - power supply of the meter................................................................. 6LR61 type 9 V battery - display.........................................................................................4000 readouts, backlit LCD - continuity test.........................................................I < 0.5 mA, acoustic signal for R < 50 Ω - diode test......................................................................................I = 0.3 mA, U0 = 1.5 V DC - indication of range overflow ..............................................................................."OL" symbol - frequency of measurements................................................................2 readouts per second - input impedance...............................................................................10 MΩ (V DC and V AC) - clamp size...............................................................................opening approx. 30 mm (1.2") - auto-off timeout...................................................................................... approx. 30 minutes - dimensions....................................................................................................197x70x40 mm - weight.......................................................................................................................... 183 g - compliance with standards..................................................... EN 61010-1, EN 61010-2-032 - quality standard...................................................................................................... ISO 9001
Nominal operating conditions: - operating temperature.......................................................................................... 0...+40 °C - storage temperature...........................................................................................-20...+60 °C - operating humidity..................... max. 80% up to 31 °C decreasing linearly to 50% at 40 °C - operating altitude .............................................................................................max. 2000 m
66
Measurement of direct and alternating voltage (TRUE RMS) Display range
Resolution
0...6.599V
0.001V
6.60...65.99V
0.01V
66.0...600.0V
0.1V
Accuracy (DC)
Accuracy (AC)
±(1.5% m.v. + 3 digits)
±(1.8% m.v. + 5 digits) for f=50...60Hz
Measurement of resistance Display range
Resolution
Accuracy
0.0...659.9Ω
0.1 Ω
±(1.0% m.v. + 4 digits)
0.660...6.599kΩ
0.001kΩ
6.60...65.99kΩ
0.01 kΩ
66.0...659.9kΩ
0.1 kΩ
0.660...6.599MΩ
0.001 MΩ
±(2.5% m.v. + 3 digits)
6.60...66.00MΩ
0.01 MΩ
±(3.5% m.v. + 5 digits)
±(1.5% m.v. + 2 digits)
Display range
Resolution
Accuracy
30.0...999.9Hz
0.1Hz
1.000...9.999kHz
0.001kHz
10.00...15.00kHz
0.01kHz
±(1.2% m.v. + 2 digits) sensitivity: 30Hz...5 kHz: 10 Vrms min. 5kHz...15 kHz: 40 Vrms min. for 20...80% of duty cycle
“m.v.” = “measured value”.
White light backlit display.
Index: WMXXCMP200
Backlit LCD. Relative measurement function.
for f=50...60Hz
Measurement of frequency
Additional functions of the meters:
Reinforced, impact resistant enclosure.
for f=50...60Hz ±(2.8% m.v. + 8 digits)
Standard accessories of the meter:
“m.v.” = “measured value”.
Safe, insulated measurement clamp.
±(2.5% m.v. +5 digits)
660...1000A ±(2.8% m.v. +8 digits) * dokładność sondy typu K nie1Ajest uwzględniana
Measurement of direct current (CMP-401 only) Display range
0.1A
Accuracy (AC) ±(2.5% m.v. + 8 digits)
IP 40 Other technical specifications: - type of insulation...............................double, in acc. with EN 61010-1 and IEC 61557 - power supply of the me....................................................... 2 AAA size 1.5V batteries - frequency of measurements......................................................2 readouts per second - display..............................................................................LCD, 3½ digits (max. 1999) - dimensions..........................................................................................182x61x34 mm - weight of the meter (including batteries).............................................................225 g - auto-off idle timeout......................................................................approx. 15 minutes - compliance with standards........................................... EN 61010-1, EN 61010-2-032
Measurement of alternating current up to 200 A: - high resolution (0.1 mA), - 3 measurement sub-ranges: 200 mA, 2 A, 200 A.
Measurement of current
Other technical specifications: - power supply of the meter................................................................ 6LR61 type 9 V battery - display........................................................................................ 6600 readouts, backlit LCD - continuity test................................................ threshold 40; measurement current < 0.5 mA - diode test.................................................................... typical measurement current 0.3 mA ....................................................................................... typical open circuit voltage < 3 V DC - indication of low battery level.................................................. the 'BAT' symbol is displayed - indication of range overflow ..............................................................................."OL" symbol - frequency of measurements...................................... 2 readouts per second, nominal value - INRUSH........................................................................................... integration time 100 ms - temperature sensor............................................................................... K type thermocouple - input impedance.............................................................................. 10 MΩ (V DC and V AC) - AC bandwidth........................................................................... 50...400 Hz (A AC and V AC) - auto-off timeout...................................................................................... approx. 25 minutes - dimensions................................................................................................... 229x80x49 mm - weight.......................................................................................................................... 303 g - compliance with standards..................................................... EN 61010-1, EN 61010-2-032
Nominal operating conditions:
Display range
Resolution
Accuracy
199.9 mA
0.1 mA
±(5% m.v. + 8 digits)
1.999 A
0.001 A
±(5% m.v. + 10 digits)
199.9 A
0.1 A
±(2.5% m.v. + 10 digits)
Nominal operating conditions: - operating temperature ............................................. 0...+30 °C (humidity up to 90%) ............................... 30...40 °C (humidity up to 75%), 40...50 °C (humidity up to 45%) - storage temperature.................................................... -25...+60 °C at humidity <90% - operating altitude .................................................................................. max. 3000 m
- internal diameters of clamps.......................................................................... Ø = 34/52 mm - operating temperature ........................................................................................ +5...+50°C - storage temperature........................................................................................... -20...+60°C - operating humidity.............................................................................. max. 80% up to 31°C ......................................................................................... decreasing linearly to 50% at 40°C - storage humidity ........................................................................................................ < 80% - operating altitude ............................................................................................ max. 2000 m
67
2 YEAR WARRANTY