Preview only show first 10 pages with watermark. For full document please download

Co-linear Venting

   EMBED


Share

Transcript

530I Direct Vent May 2014 FS or Flush Co-Linear Venting Co-linear Venting into Existing Solid-Fuel Burning Fireplaces and Chimneys Co-linear adapter may be installed as top or rear outlet. • Co-linear and co-axial venting may be combined in a single venting system provided conversion is done only once using approved components and maintaining proper clearances; • Three-inch liners may only be installed into solidfuel burning fireplaces and chimney systems (no combustible construction); • The appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. • Restrictors not required for co-linear sidewall venting with less than 5’-0” vertical rise. For restrictor settings beyond 5’-0” refer to chart in appliance’s installation manual. 1/2 556CLA 3/4” 2 x 3” liners 2 x 3” liners 3/4” 556CLA 25-1/4” 25-1/4” 9 to 11-1/2” depending of front used - see front manual 9 to 11-1/2” depending of front used - see front manual 556CLA Rear Mounted 556CLA Top Mounted Flashing 3” min. bend radius 2 x 3” liners Approved co-linear termination or approved co-linear adapter and approved co-axial termination 556CLA Co-Linear Adapter 720SWK Terminal 3” min. Bend Radius 3” Liners Min. 3’-0” *Max. 5’-0” May be used with top or rear outlet (requires 556CLA Co-Linear Adapter) Co-linear adapter 40’ max 8’ min 18” max. horizontal run 2 x 3” liners 530 engine 24-1/2” Co-linear adapter * May be extended beyond 5’-0”. Refer to the 720SWK installation instructions Sidewall co-linear installation into existing F/P using 720SWK—for units with logs or rocks only Vertical co-linear installation into existing F/P Miles Industries Ltd. • 190—2255 Dollarton Highway • North Vancouver, BC • V7H 3B1 Tel: 604.984.3496 or 1.800.468.2567 • Fax: 604.984.0246 or 1.800.268.0333 www.valorfireplaces.com 530I Direct Vent May 2014 FS or Flush Co-Linear Venting 2/2 10” 10” 7-5/8” dia. collar 3” Inlet & Exhaust Collars Front 559CLT Co-Linear Vertical Terminal 559FSK Flashing Kit Rear 720SWK Sidewall Horizontal Terminal —for logs or rocks units only Alternate to 556CLA/559CLT/559FSK Conversion for vertical termination Co-Linear to Co-Axial Adapter Flashing Co-Axial to Co-Linear Adapter Terminal Cap Miles Industries Ltd. • 190—2255 Dollarton Highway • North Vancouver, BC • V7H 3B1 Tel: 604.984.3496 or 1.800.468.2567 • Fax: 604.984.0246 or 1.800.268.0333 www.valorfireplaces.com