Transcript
530I Direct Vent May 2014
FS or Flush Co-Linear Venting Co-linear Venting into Existing Solid-Fuel Burning Fireplaces and Chimneys Co-linear adapter may be installed as top or rear outlet. • Co-linear and co-axial venting may be combined in a single venting system provided conversion is done only once using approved components and maintaining proper clearances; • Three-inch liners may only be installed into solidfuel burning fireplaces and chimney systems (no combustible construction); • The appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. • Restrictors not required for co-linear sidewall venting with less than 5’-0” vertical rise. For restrictor settings beyond 5’-0” refer to chart in appliance’s installation manual.
1/2 556CLA
3/4”
2 x 3” liners
2 x 3” liners
3/4” 556CLA
25-1/4”
25-1/4”
9 to 11-1/2” depending of front used - see front manual
9 to 11-1/2” depending of front used - see front manual
556CLA Rear Mounted
556CLA Top Mounted
Flashing 3” min. bend radius
2 x 3” liners
Approved co-linear termination or approved co-linear adapter and approved co-axial termination
556CLA Co-Linear Adapter
720SWK Terminal 3” min. Bend Radius
3” Liners
Min. 3’-0” *Max. 5’-0”
May be used with top or rear outlet (requires 556CLA Co-Linear Adapter)
Co-linear adapter
40’ max 8’ min
18” max. horizontal run
2 x 3” liners
530 engine 24-1/2”
Co-linear adapter
* May be extended beyond 5’-0”. Refer to the 720SWK installation instructions
Sidewall co-linear installation into existing F/P using 720SWK—for units with logs or rocks only
Vertical co-linear installation into existing F/P
Miles Industries Ltd. • 190—2255 Dollarton Highway • North Vancouver, BC • V7H 3B1 Tel: 604.984.3496 or 1.800.468.2567 • Fax: 604.984.0246 or 1.800.268.0333 www.valorfireplaces.com
530I Direct Vent May 2014
FS or Flush Co-Linear Venting
2/2
10”
10”
7-5/8” dia. collar 3” Inlet & Exhaust Collars
Front
559CLT Co-Linear Vertical Terminal
559FSK Flashing Kit
Rear
720SWK Sidewall Horizontal Terminal —for logs or rocks units only
Alternate to 556CLA/559CLT/559FSK Conversion for vertical termination Co-Linear to Co-Axial Adapter
Flashing
Co-Axial to Co-Linear Adapter
Terminal Cap