Transcript
Product Datasheet P/N 49307 Rev. 1A Page 1 of 2 Date 22-11-2001
COAX4 FOAM FB 14 PE
Application Trunk coaxial cable used in HFC / CATV broadband communication networks for burial use Key features • • • • •
Physical foam PE dielectric All copper conductor material Jacket of PE Test methods in accordance with European standard EN 50117-1. Designed according the European Standard EN 50117 operating at frequencies between 5 MHz and 2150 MHz and the International Standard IEC 1196. Construction & Dimensions
1
1 2 3.1 3.2 4
2
3.1
3.2
Inner conductor Dielectric Foil Braid Sheath
4
Solid soft annealed copper Physical foam PE Copper Annealed copper PE
1. Inner conductor diameter: 2. Dielectric diameter: 3. Outer conductor diameter: 4. Sheath diameter:
2.23 mm ± 0.03 mm 10.2 mm ± 0.2 mm 11.0 mm ± 0.3 mm 13.8 mm ± 0.4 mm
Mechanical characteristics Adhesion of dielectric: Tensile strength of sheath: Elongation of sheath at break: Crush resistance of cable: Storage temperature: Operating temperature: Minimum installation temperature: Maximum tensile strength of cable: Minimum static bend radius: Total weight:
35 – 350 N at 50 mm ≥ 10 N/mm2 ≥ 300 % < 1% (load of 700N) -40°C to +70°C -40°C to +70°C -5 °C 400 N 150 mm 170 g/m
Belden Wire & Cable B.V. All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner
Product Datasheet P/N 49307 Rev. 1A Page 2 of 2 Date 22-11-2001
COAX4 FOAM FB 14 PE
Electrical characteristics Mean characteristic impedance: Regularity of impedance: DC loop resistance: DC resistance inner conductor: DC resistance outer conductor: Capacitance: Velocity ratio: Insulation resistance: Voltage test of dielectric: Screening efficiency 30-1000 MHz: Return loss at 5-30 MHz: 30-470 MHz: 470-862 MHz: 862-2400 MHz: Attenuation at Nominal 5 MHz: 0.7 dB/100m 50 MHz: 2.1 dB/100m 100 MHz: 3.1 dB/100m 200 MHz: 4.4 dB/100m 400 MHz: 6.6 dB/100m 600 MHz: 8.3 dB/100m Maximum attenuation is 10 % higher.
75 ± 4 Ω > 46 dB ≤ 9.0 Ω/km ≤ 4.5 Ω/km ≤ 4.5 Ω/km 54 pF/m ± 2 pF/m 0.82 ± 0.02 > 104 MΩ.km 3 kVdc ≥ 100 dB ≥ 25 dB* ≥ 25 dB* ≥ 23 dB* ≥ 21 dB* *Max. 3 peak values 4 dB lower than specified. Attenuation at 800 MHz: 1000 MHz: 1350 MHz: 1750 MHz: 2150 MHz: 2400 MHz:
Nominal 9.6 dB/100m 11.0 dB/100m 13.5 dB/100m 15.3 dB/100m 17.3 dB/100m 19.2 dB/100m
Ordering information MARKING Text Inkjet printing BELDEN VENLO HOLLAND YYYY COAX 4 FOAM FB Metermarking: Yes YYYY: Year of production. Other marking on request. PACKAGING Belden code Delivery length 49093 xxxx 023 1000 m ± 5% 49093 xxxx 025 500 m ± 5% xxxx: Color code Other packaging or lengths on request.
Remark Non returnable reel Non returnable reel
Belden Wire & Cable B.V. All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner