Preview only show first 10 pages with watermark. For full document please download

Cold Start Procedure

   EMBED


Share

Transcript

Advanced Simulation Technology inc. 500A Huntmar Park Drive Herndon, Virginia 20170 USA Tel. (703) 471-2104 • Fax. (703) 471-2108 www.asti-usa.com ASTi ACE Studio Cold Start Guide Document: DOC-02-TEL4-ASCS-1 Advanced Simulation Technology inc. 500A Huntmar Park Drive Herndon, Virginia 20170 USA Revision K, Version 2 (March, 2016) Product Name: Telestra 4 ACE Studio ASTi ACE Studio Cold Start Guide © Copyright ASTi 2010–2016. Restricted Rights: Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013. This material may be reproduced by or for the U.S. Government pursuant to the copyright license under the clause at DFARS 252.227-7013 (1994). ASTi 500A Huntmar Park Drive Herndon, Virginia 20170 USA Red Hat® Enterprise Linux Red Hat® Subscription ASTi’s ACE software is designed to run on an installation of Red Hat® Enterprise Linux® client. This ensures optimal interoperability with ASTi’s ACE software, host routing software and external communications servers. As such included in the cold start DVDs is the complete installation of Red Hat® Enterprise Linux® client. This software is not activated to a current Red Hat subscription. It is the end users' responsibility to activate their subscription and connect to the Red Hat Network. The Red Hat subscription will provide the end user with support, maintenance, software, and security updates. For details on Red Hat activation, see the Red Hat web site: https://www.redhat.com/apps/activate Export Restriction Countries other than the United States may restrict the import, use, or export of software that contains encryption technology. By installing this software, you agree that you shall be solely responsible for compliance with any such import, use, or export restrictions. For full details on Red Hat export restrictions please visit: http://www.redhat.com/licenses/export Table of Contents 1.0 Overview 1 2.0 Requirements 2 3.0 Backup System Configuration 3 4.0 Media Check 4 5.0 ACE Studio Cold Start Instructions 5 5.1 Installing Red Hat Versions 4.10 and Higher 5 5.2 Installing ACE Studio Versions 4.5 and Higher 7 6.0 ACE Studio Development Workstation Setup 7.0 Memory Test 9 12 7.1 ACE Studio Versions 4.31 and Higher 12 7.2 ACE Studio Versions 4.10–4.30 13 Appendix A: Installation Instructions for Older Software Versions 14 A-1 Installing RHEL Software 14 A-2 Installing ACE Studio Software 14 i ASTi ACE Studio Cold Start Guide (Ver. 2, Rev. K) 1.0 Overview The cold start procedure described in this document allows users to build ACE Studio systems from scratch. There are three main reasons for using the cold start procedure: l Installing the latest software version. l Rebuilding a damaged hard disk. l Creating spare hard disks. Caution: Performing a cold start procedure will completely erase the system hard drive. Copyright © 2016 Advanced Simulation Technology inc. 1 ASTi ACE Studio Cold Start Guide (Ver. 2, Rev. K) 2.0 Requirements This cold start procedure is only for use with the ACE Studio system. Note: To install ACE Studio on a virtual machine, see the ACE Studio VM Quick Start Guide (DOC-01-ASVM-QSG-4). You will need the following items: l 2U platform with removable hard drive l Telestra ASTi Software Installation DVD l Red Hat Software Installation DVD l Power connection l Connected keyboard, monitor, and mouse l (Optional) ASTi Information Assurance (IA) DVD Figure 1: Telestra 2U Rear Panel Note:The chassis and connections shown here are for general representation only; the location(s) of cards, ports, and slots may vary. Consult the included engineering drawings and labels on the rear of your chassis for specific designations. Caution: Remove all external drives connected to the system before starting the cold start procedure. Failure to do so may erase the external drives. 2 Copyright © 2016 Advanced Simulation Technology inc. ASTi ACE Studio Cold Start Guide (Ver. 2, Rev. K) 3.0 Backup System Configuration The System Configuration Backup page creates an archive of backup files on the workstation. This page includes the following settings: l Options: includes all options files loaded on the system. l Projects Archive: includes all projects archived on the system. l RMS Users and Config: includes user information (e.g., passwords, lockout settings) l l Sound Library: the library of sound files on the system, including the project's index and WAV files. Telestra Config: includes configurations settings (e.g., network settings, preferences). Figure 2: Backup System Configuration Page To create a system backup, follow these steps: 1. In the Remote Management System (RMS), go to the System Configuration Backup page. 2. Check all or some of the desired configuration sections, and select Start Backup. 3. When the backup is complete, download the .tgz file to a local system. Caution: Do not save backup files on the development workstation. The cold start procedure will erase any backup files saved in this location. Copyright © 2016 Advanced Simulation Technology inc. 3 ASTi ACE Studio Cold Start Guide (Ver. 2, Rev. K) 4.0 Media Check This step is optional. Follow the instructions below to verify the integrity of the installation media. This procedure is useful if you suspect a problem with your DVD. The verification will fail if a file on the DVD is unreadable due to scratches, marks, etc. The DVD contents should only be verified once, whether you are cold starting one or several systems with the same DVD. To perform the check, users must have access to the sh shell and md5sum executable files. Note: The ASTi development workstation provides these resources by default and is the recommended computer to use for media verification. To verify DVD contents, follow these steps: 1. Power on the development workstation. As it boots, insert the Telestra ASTi Software Installation DVD into the disk drive within 10 seconds of powering on. Important: If the development workstation boots from the hard drive, reboot the system, and hold down the Alt key as it restarts. 2. At the prompt, type studio mediacheck, and press Enter. 3. The prompt will read, “CD Not Found” as the system ejects the Telestra ASTi Software Installation DVD. Remove the DVD. 4. Insert the Red Hat Software Installation DVD, and select OK. 5. The system prompt opens for the DVD media check. Select Test to begin the media check. The test will take approximately five to ten minutes to complete. 6. Upon completion, the Media Check Result should read, “Media Check Passed.” If the DVD verification passes, select OK to continue. If the DVD verification failed, contact ASTi immediately to receive new software DVDs. 7. The DVD will eject from the disk drive. Remove the DVD. Caution: Failure to remove the DVD after verification will completely erase and reformat the hard disk the next time the system is booted. 8. The prompt will ask if any other media needs to be checked. 9. Repeat Steps 1–7, but replace the Red Hat Software Installation DVD with the Telestra ASTi Software Installation DVD in Step 4. 10. If the DVD verification was successful, proceed with the cold start procedure. 4 Copyright © 2016 Advanced Simulation Technology inc. ASTi ACE Studio Cold Start Guide (Ver. 2, Rev. K) 5.0 ACE Studio Cold Start Instructions Important: Do not connect Keyboard Video Mouse (KVM) switches to the system during the cold start procedure. If you run into an issue with the procedure while using a KVM, disconnect it, and try the cold start procedure again with a dedicated keyboard, monitor, and mouse. 5.1 Installing Red Hat Versions 4.10 and Higher To install Red Hat versions 4.10 and above, follow these steps: 1. Power on the system via the power switch. 2. Insert the Telestra ASTi Software Installation DVD immediately, and ensure that the system boots from the DVD. 3. At the prompt, select RHEL Studio [Default]. Note: For ACE Studio software versions 4.30 and lower, the prompt screen is different. At the prompt, type studio, and press Enter. Figure 3: ACE Cold Start Menu Note: Alternate Red Hat versions are available. Select the installation that corresponds with your system (i.e., ACE Studio). Copyright © 2016 Advanced Simulation Technology inc. 5 ASTi ACE Studio Cold Start Guide (Ver. 2, Rev. K) 4. A warning message will appear, reading "CD Not Found." Press OK, and the system will eject the Telestra ASTi Software Installation DVD. Remove the DVD. Figure 4: CD Not Found Message 5. Insert the Red Hat Software Installation DVD, and select OK. 6. Wait for the installation to complete. 6 Copyright © 2016 Advanced Simulation Technology inc. ASTi ACE Studio Cold Start Guide (Ver. 2, Rev. K) 7. As described in the display, remove the DVD, and use the Tab key to select Reboot, as shown in the figure below. Figure 5: Installation Complete Screen 5.2 Installing ACE Studio Versions 4.5 and Higher Note: To install ACE Studio on a virtual machine, see the ACE Studio VM Quick Start Guide (DOC-01-ASVM-QSG-4). Before continuing with this installation, complete Section 5.1, "Installing Red Hat Versions 4.10 and Higher" on page 5. To install ACE Studio versions 4.5 and higher, follow these steps: 1. Log into the system with the following credentials: Username Password root abcd1234 2. Insert the Telestra ASTi Software Installation DVD. 3. To open the terminal, navigate to Applications > Accessories > Terminal. 4. To instruct the computer to access the DVD, type mount /dev/dvd /media, and press Enter. 5. At the prompt, type sh /media/install, and press Enter. Copyright © 2016 Advanced Simulation Technology inc. 7 ASTi ACE Studio Cold Start Guide (Ver. 2, Rev. K) 6. The prompt will read, "Select a product to install." Use the Up and Down Arrow keys to select ACE Studio. Then use the Tab key or the Right Arrow key to select OK. Figure 6: ACE Product Install Screen Note: To install ACE Studio on a virtual machine, see the ACE Studio VM Quick Start Guide (DOC-01-ASVM-QSG-4). 7. The prompt will read, "Do you wish to install ACE Studio?" Select Yes. Wait for the installation to complete. 8. Type eject /media, and press Enter. 9. Remove the DVD from the drive. 10. To reboot the system, type reboot, and press Enter. 11. To set up your IP address, continue to Section 6.0, "ACE Studio Development Workstation Setup" on the facing page. Note: For step-by-step instructions on installing ASTi Information Assurance (IA) software, see the ASTi Information Assurance Software Installation Procedure (DOC-01-IAIP-1). 8 Copyright © 2016 Advanced Simulation Technology inc. ASTi ACE Studio Cold Start Guide (Ver. 2, Rev. K) 6.0 ACE Studio Development Workstation Setup To complete the set up you will need the following hardware: l Monitor l Keyboard l Mouse l ACE Studio development workstation l Category 5e cable or better l Network connection from ACE Studio to Target The ACE Studio development workstation will not have an IP address without a DHCP network connection. To set up the ACE Studio development workstation and assign an IP address to the system, follow the steps below: 1. Connect the monitor, keyboard, and mouse to the development workstation. 2. Connect the development workstation to the same network as the Target. 3. Power on the development workstation, and allow it to boot. 4. In the top left corner, select System > Administration > Network. Figure 7: Network Settings Option Copyright © 2016 Advanced Simulation Technology inc. 9 ASTi ACE Studio Cold Start Guide (Ver. 2, Rev. K) 5. Check the Profile check box, and select Edit. Figure 8: Network Configuration Property Sheet 6. Select the Statically Set IP Addresses button. Figure 9: Ethernet Device Property Sheet 7. In the Address text field, enter the IP address. 10 Copyright © 2016 Advanced Simulation Technology inc. ASTi ACE Studio Cold Start Guide (Ver. 2, Rev. K) 8. In the Subnet mask text field, enter the subnet mask. Ask your network administrator for valid IP addresses and subnet masks for the network(s) where the Target and ACE Studio development workstation will be integrated. 9. Enter the default gateway. If the network does not have a gateway, enter the IP address from Step 7 in this field. 10. Reboot the ACE Studio platform. Copyright © 2016 Advanced Simulation Technology inc. 11 ASTi ACE Studio Cold Start Guide (Ver. 2, Rev. K) 7.0 Memory Test The Memory Test is a useful troubleshooting tool if you are experiencing problems such as system lockup, freezing, random rebooting, or graphics/screen distortion. ASTi recommends running this test several times to ensure that the memory is fully functional. You may wish to run the test overnight. 7.1 ACE Studio Versions 4.31 and Higher To complete the Memory Test, follow the steps below: 1. Power on the computer. 2. Insert the Telestra ASTi Software Installation DVD, and reboot by pressing the Reset button on the front of the development workstation. 3. At the prompt, select Memtest. Figure 10: ACE Cold Start Menu 12 Copyright © 2016 Advanced Simulation Technology inc. ASTi ACE Studio Cold Start Guide (Ver. 2, Rev. K) 7.2 ACE Studio Versions 4.10–4.30 To execute the Memory Test, follow these steps: 1. Power on the computer. 2. Insert the Telestra ASTi Software Installation DVD, and reboot. 3. At the prompt, type memtest, and press Enter. 4. Let the Memory Test run for an extended period of time or over night, if possible. 5. The Memory Test will continue running indefinitely until manually stopped. To stop the test, press Esc. Copyright © 2016 Advanced Simulation Technology inc. 13 ASTi ACE Studio Cold Start Guide (Ver. 2, Rev. K) Appendix A: Installation Instructions for Older Software Versions A-1 Installing RHEL Software To install ASTi software versions 4.1–4.9, follow these steps: 1. Power on the system via the power switch. 2. Select the DVD Windows icon to boot from the DVD. 3. At the prompt, type studio, and press Enter. 4. Wait for the installation to complete. When the installation is finished, the DVD will automatically eject. Remove the DVD, and select Reboot. A-2 Installing ACE Studio Software Note: If you are installing ACE Studio software versions 4.5 or higher, see Section 5.2, "Installing ACE Studio Versions 4.5 and Higher" on page 7. Before proceeding with this installation, complete Appendix A-1, "Installing ACE Studio Software" above. To install software versions 4.1–4.4, follow these steps: 1. Log into the system using the following credentials: Username Password root abcd1234 2. Insert the Telestra ASTi Software Installation DVD (previously titled ASTi DVD 2). 3. Open a terminal by navigating to Applications > Accessories > Terminal. 4. To mount the DVD, type mount /dev/dvd /media, and press Enter. 14 Copyright © 2016 Advanced Simulation Technology inc. ASTi ACE Studio Cold Start Guide (Ver. 2, Rev. K) 5. At the prompt, type sh/ media/install, and press Enter. Figure 11: Sh /media/install Command 6. The prompt will read, “Attempting to install ACE Studio, continue [Y/n].” Press the Y key to continue. The screen below will display after the installation is complete. Figure 12: Installation Complete Message 7. To eject the DVD from the drive, type eject, and press Enter. Close the terminal. 8. Navigate to System > Shutdown, and click Restart to reboot. Copyright © 2016 Advanced Simulation Technology inc. 15