Transcript
Colour fan
R
Colourfan Twin Acoustic Step by Step Guide
1
Twin Acoustic
Other products and services from the complete range of VES HVAC solutions:
Choose Duties up to 2.8 m3/s
Air Handling Units • •
Colourfan Twin Acoustic
• • • •
R
Duties up to 2.8 m3/s
Supply and extract, combined or separate. Heat recovery including crossflow plate heat exchangers, thermal wheels and run-around coils. Plantroom or weatherproof, flat or stacked. Fitted silencers, inverters and controls. Matching DX condensing units. Various case constructions including EN 1886 certified units.
• • • •
a b
In-line centrifugal, with forward or backward curved impellers. Round, axial and mixed flow fans. Fitted silencers available on all units. Manual and automatic speed controllers available.
2
Performance Curve
Unit Configuration
c d
Specify your chosen unit
Controls
co m pl ia nt
requirements, including BB93
f Wide range of models for ceiling void,
For ceiling void, plantroom and weatherproof. Many models and configurations. Fitted auto-changeover system.
to achieve L2 Building Regulations
f BlueSense Intelligent Controls, with
All types for commercial, industrial and domestic premises.
Colourfan
•
• •
Heavy duty high temperature fans for hot greasy air. Motors out of airstream. Single inlet fans, in-line and vertical jet roof units.
Control Panels
3
• • • •
Add control packages for performance and efficiency Pages 28-30
Filters
Case Construction
Prewired/Fitted Controls
Thyristor Heater
Energy Efficient Fans
Speed Control
Humidity
Temperature
Heat Recovery
Specify bespoke options for Colourfan products Page 31 R
Colourfan
Off the shelf and built to order panels. Air quality sensors and energy savers. Intelligent control software. A range of remotes including touch screen.
• • •
Matching silencers available for all ventilation products. Silencers designed to meet noise criteria. Cleanable silencers. Weatherproof silencers.
Specialist Site Services • • • • • • • •
Plant refurbishment. Energy saving upgrades. Noise reduction. Site surveys. Kitchen ventilation. AHU flat pack installation. Maintenance. Spares.
R
Supply Acoustic and Supply Units
Noise Control •
Plug & Play
4
Demand Ventilation
R
Twin Units
duty share for continuous ventilation
Kitchen Hood Extract Fans
Noise Data and Silencer Option
Refer to pages 6-27.
Also available...
f High efficiency EC fans with Low SFPs
Three ranges for volume and pressure. Curb and soaker sheet bases.
The Colourfan Twin Acoustic high efficiency, low noise unit with duties up to 2.8 m3/s, low Specific Fan Power and low energy / high efficiency fans.
plantroom and external locations
Wall and Ceiling Fans •
Twin Acoustic DUTIES UP 3 to 2.8 m /s
to BS EN ISO 3744:2010
f Low noise to help meet acoustic
Roof Extract Units • •
R
f Independent Acoustic Testing
Twin Fans • • •
Colourfan
Duties up to 2.8 m3/s
Duct Fans
R
Buy from
Colourfan Twin Acoustic Unit
Member
C
Colourfan Twin Acoustic R
VES reserve the right to amend product specifications and details without notice.
VES Head Office Eagle Close, Chandlers Ford Industrial Estate, Chandlers Ford, Eastleigh, Hampshire SO53 4NF Tel: 08448 15 60 60 Fax: 023 8026 1204
R
Extract Acoustic and Extract Units
2013 VES
Issue CAT01W - 07/2013 www.vesdirect.co.uk
Colourfan
part of a complete range of innovative, flexible products from the HVAC experts
VES Manchester Office Unit 6, Willan Enterprise Centre, 4th Avenue, The Village, Trafford Park, Manchester M17 1DB Tel: 0161 848 8711 Fax: 0161 848 7268
For details on Colourfan product codes please turn to the back of this flap.
VES Glasgow Office Unit 15, Evans Business Centre, Springhill Parkway, Glasgow Business Park, Glasgow G69 6GA Tel: 0141 771 6823 Fax: 0141 771 6892
ves.co.uk
vesdirect.co.uk
[email protected]
R
R
Colour fan Twin Acoustic
Product Code Guide
R
R
Product R
Fan Type Fan Size Phase
Colourfan Twin Acoustic
Unit Size Unit Config
/EE
Infill Handing
Case Construction
Main Heating [null] Control Panel Section
Options Colour Name Part No.
Ancillaries Examples
Inlet/Outlet
R
33
[null]
Intelligent controls enhance performance whilst saving energy and money.
Main Filter
Heat Recovery
CAT
Temperature
Energy Saving
CPF0-1/P/C CATVA0000/1200/STD NRGEX9000
Humidity
Thyristor Heater
Control Panel Silencer Feet
Plug & Play
Air Quality
[null] /R7004
Filters
/SP /L
Speed Control
Case Construction
/ISC /CPSC
Energy Efficient Fans
Demand Ventilation
/PH /WH
Prewired/Fitted Controls
Colour
Manufactured in the UK
Download specification from www.ves.co.uk/information-centre
Please note: Weatherproof units are supplied in R7004 powdercoating as standard
4
Excellent build quality ensures minimal noise breakout, low SFPs and air tight performance.
[null]=Galvanised /R=RAL (colours)
1
/RT /RB /LT /LB
Inlet / Outlet /SP=Square Spigot /L=Louvre
F. Dampers shall be of opposed blade type, incorporating gasket seals between blades and sealed angles on the frame to ensure maximum sealing efficiency when the blades are closed.
Robust Construction
-1 -1 -1 -1 -1 -1 -1 -3
E. Dampers shall incorporate an aluminium extruded channel frame and aluminium damper blades, mounted on nylon cogs with nylon bearing inserts. Blade operation shall be via a 12mm sq. spindle mounted to one side of the damper.
G. Dampers shall be suitable for use with optional 230 VAC or 24 VAC open/close actuator as supplied by VES Andover Ltd.
VES employs a range of experts in disciplines including: air movement, noise control, air conditioning, controls, electrics and product refurbishment, and we have key staff who have worked at VES for many years.
-3
C. The silencer casework shall be provided naturally finished in high quality galvanised steel as standard. Internal and external powder coat available as indicated in the schedule. Colour to be in accordance with schedule. D. The plantroom unit shall be fully compatible with loose spigot mounted dampers suitable for direct fitting to the unit.
5
1 1 2 3 4 5 6 7
co mp lia nt
Main Filter [null]=No Filters
3
A. The unit shall be fully compatible with a standard range of spigot mounted silencers. The silencers shall be suitable for duct mounting or direct mounting to the unit as indicated in the schedule. B. The silencer shall be a rigidly constructed 50mm tubular aluminium case double skinned galvanised sheet steel panels incorporating internal splitters lined with resin bonded mineral wool. Polythene and perforated metal sheet lining shall be available where indicated in the schedule.
Control Panel Section /ISC=Isolator and Speed Control /CPSC=Control Panel and Speed Control
6
5 4 4 4 4 4 4 4
L. 7 day time.
1.7 Ancillaries
Versatile location, handing and access options meet the widest range of project requirements.
00 01 02 03 04 05 06 07
K. Start stop from remote volt free contacts.
N. Volt free enable, and 24 VDC fire alarm interface.
Versatile Options
-3
J. Duty share with 12 hour run-time memory retention.
M. Volt free run and trip indicators.
2
8
I. Fully programmable digital controller with commissioning and adjustment for constant pressure, humidity and temperate applications.
4
H. Automatic fan change over on airflow failure.
08
Infill /EE = 50mm
G. Fitted controls shall be fully pre-wired to internal components.
-3
F. Fitted controls shall be supplied with a wired AHU mounted LCD controller. Optional room user interfaces are available.
9
E. Control panels shall have individual circuit breakers where indicated in the schedule and detail drawings.
Handing /RT=Right Top /RB=Right Bottom /LT=Left Top /LB=Left Bottom
Simple connection and pre-installed features save on site costs and reduce lead times. Carefully designed maintenance features minimise downtime and total cost of ownership.
D. Controls shall be supplied with internally mounted circuit breakers, run, trip and panel live indication and lockable door isolation switch.
10
B. The unit shall be available with optional unit mounted CPF control panel as manufactured and factory fitted by VES Andover Ltd to suit, or alternative loose CPF panel for installation by others. If no control panel is ordered the unit will be supplied with local isolator for unit mains connections.
4
A. The unit shall be fitted as standard with EC fan speed control system to match fan type with max/min speed and 0-10 VDC BMS control, i.e. Air Quality or Temperature sensor.
4
1.6 Controls
09
A. The unit shall be designed to operate with process air temperatures from -20 OC to 40 OC, and humidity up to 80%.
Main Heating [null]=No Heating
Simple Installation and Maintenance
Experience and expertise
VES has over 12000m2 of manufacturing and stores space, and has state of the art sheet metalworking equipment, plus a large powder coating plant. VES also has a substantial controls department, and makes components such as dampers and electric heaters in-house. This not only provides employment for local people, but also many suppliers around the UK.
1.5 Operation Environment
C. Fitted Controls shall be positioned as indicated in the schedule and detail drawings.
VES operates a quality assurance system to ISO 9001, monitored by the BSI. The air movement products are tested in-house to BS EN ISO 5801:2008, BS 848-1:2007 and submitted for external testing and approval when necessary. VES specialise in bespoke designs for ventilation units. Whatever the issue, be it space, noise or temperature, VES can provide a design solution to meet the requirements of the project.
From the moment we receive your enquiry, to delivery and beyond; we have the people in place to give excellent customer service. The VES after sales service covers the whole of the UK and is among the best in the industry.
Energy saving packages combine intelligent controls technology, products and services.
R
High quality, flexible solutions
Superior customer service
Optimum Performance Our quietest twin air handling unit, meeting regulations and maximising performance.
10
The product range encompasses all types of ventilation products, including those required for commercial, industrial, public and domestic buildings. The emphasis is on low energy products and sophisticated controls to meet Building Regulation requirements. The range extends from a small bathroom extract fan up to large bespoke air handling units. There are specialist heat recovery units; high temperature fans for kitchen hood extract; duct, wall, ceiling and roof units; low noise products, silencers and fitted controls.
Features and Benefits
Product CAT=Colourfan Twin Acoustic
The Colourfan Twin Acoustic is suitable for many installations including schools, offices, libraries, hotels and retail establishments. Designed to fit any application, the units have been independently acoustically tested to BS EN ISO 3744:2010.
Colourfan Twin Acoustic
Unit Config /PH=Plantroom Horizontal Inlet/Outlet /WH=Weatherproof Horizontal Inlet/Outlet
Complete range of products
R
Colourfan is a range of small air handling ventilation units from VES, including Supply, Extract and Twin Extract, designed around a single product platform, with unique and innovative benefits across the range. Installation and maintenance is simplified through quick change “Plug & Play” connectors or pre-wired fitted controls.
Example Coding
VES has been supplying products for the HVAC industry for over 40 years, and have the in-depth knowledge and resources to provide solutions to all ventilation related requirements. We are a substantial British manufacturing company with over 250 employees, several factories plus a regional base in the north of England, and sales engineers located throughout the UK.
Colourfan Twin Acoustic
Twin CAT 0051-1/PH/EE/LT/CPSC/L
Why choose VES
Energy Efficient
Energy efficient units with low SFPs to help achieve L2 Building Regulations. Units are fully tested to BS EN ISO 5801:2008, BS 848-1:2007 (airside performance) and BS EN ISO 3744:2010 (acoustic performance).
Complete Ventilation Package VES offer the expertise, products and services to provide a complete ventilation package including integrated controls and site assistance, providing peace of mind through reliable products and expert knowledge.
3
5
Easy Connections
Rectangular spigot connections are fitted with 30mm MEZ flange, avoiding the need for additional accessories.
‘Plug & Play’ Fans
Fan motor assembly is internally anti-vibration isolated and fitted with a quick change plug connector for easy maintenance.
Noise Reduction
1
Our quietest twin extract air handling unit has been independently tested to BS EN ISO 3744:2010 and can help meet acoustic requirements for sensitive applications including BB93; Building Bulletin 93 - School Acoustics.
High Performance Fans
2
Backward curve EC Fans offering maximum efficiency, minimum energy consumption, fully controllable and ErP2015 compliant.
Pre-wired Isolator & Controls
4
The unit can be pre-wired to an integral isolator or integral controls package to reduce on site wiring.
Duty Share
6
The CPF Twin Controls provide automatic changeover upon fan failure to ensure continuous extract ventilation, including a time dependent duty share function.
Multi Access
Adjustable Mounting Feet
Versatile Handings
Section Joins
Excellent Construction
Powdercoat Options
Plantroom units suitable for top or bottom access to fans, left or right access to controls. External units are top access only.
Weatherproof units size 0-3 are supplied with adjustable feet for uneven surfaces and sizes 4-10 are supplied on channel bases. Plantroom units can be supplied with optional feet.
Handings can be left or right hand side to suit site and/or installation requirements.
External joining brackets for silencer connections for simple installation of unit and silencer.
Double skinned cases available in plantroom or weatherproof. All units constructed to BS EN 1886, with 50mm aluminium tubular frame and galvanised sheet steel panels, with high density resin bonded mineral wool slab infill.
External units are powder coated Signal Grey to RAL7004 as standard, with many other colours available.
BlueSense Energy Saving Package
= Colourfan Acoustic Unit with Integral Controls
EC fan - with full control
Sensor options
The sign of energy saving products, services and expertise
For more information refer to pages 28-29 1
Colour fan Twin Acoustic R
Supply, Extract or Twin Extract Working Together
The Colourfan Supply Acoustic unit with integrated controls can work seamlessly with any Colourfan Extract Acoustic or Colourfan Twin Extract Acoustic unit. This provides fully protected motor and control signals that can be wired directly to the isolator on the Extract Acoustic or Twin Acoustic unit, reducing the need for any other control requirements and easing site installation. Colourfan Extract Acoustic with Isolator
Colourfan Extract Acoustic with isolator
Colourfan Supply Acoustic Filter, Fan, EHB, Coil, complete with integral Controls package
Conference Room Application
Colourfan Supply Acoustic Filter, Fan, LPHW, Coil, complete with integral Controls package
Small Office Application
PIR and Air Quality Sensor
Changing Room with Showers Application
LCD Room Unit
Colourfan BlueSense TM
All products in the Colourfan range can form part of the BlueSense energy saving commitment. By specifying a BlueSense package you are ensuring your Supply Acoustic, Extract Acoustic or Twin Acoustic unit is optimised with a pre-wired controls package, energy efficient speed controller and air quality sensor, all programmed to work in unison, reducing energy consumption and saving money.
Colourfan Twin Extract Acoustic Unit complete with integral Controls package
Colourfan Supply Acoustic Fan, Filter unit complete with integral Controls package
Optional loose Heatline EHB
Controls Communication (Units may require internal protection in heavy usage applications)
Pre-wired Controls
= Colourfan Acoustic Unit with Integral Controls 2
EC fan - with full control
Sensor options
The sign of energy saving products, services and expertise
For more information refer to page 28-29
Colourfan Supply and Supply Acoustic Units
R
Colourfan Extract and Extract Acoustic Units
R
Colourfan Twin and Twin Acoustic Units
R
3
Colour fan Twin Acoustic R
Colourfan Twin Acoustic Performance R
Easy Selection
600
1000
550
900
500
800
450
VES Colourfan Twin Acoustic units are the versatile solution for a wide range of applications.
700
Selecting Colourfan units has been made easy, through our simple step by step process. We’ve done all of the hard work leaving you to specify and define your unit requirements.
350
Resistance (Pa)
Duties up to 2.8 m3/s
Resistance (Pa)
400
300 250
600 500 400
200
300
150 200
100 R
CAT01
CAT0
100
0.5
0.6
0.8
0.7
0.9
0
1.0
0.2
a
Performance
c
Controls
b
Unit Configuration
d
Noise and Silencer Data
Add control packages for performance and efficiency Pages 28-30
Include BlueSense integrated controls to take advantage of energy saving demand ventilation, as well as many additional benefits.
/l/ s W
1.2
90%
1.1
1.0
Resistance (Pa)
300
0.9
80%
Unit Type
0.8
250
0.7
f Variety of heating options.
70%
200
0.6
150
60%
100
50%
CAT0
0.5
50 0.4
0 0
0.01
0.02
0.03
0.04
0.05
0.06
0.07
0.08
0.2
0.09
0.3
0.1
0.11
0.12
CPF0-1/P/C
450 100%
400
350
43 35 38 30
90%
40 33 36 28
80%
38 30 33 25
Resistance (Pa)
300
250 70%
200
60%
150
50%
100
35 27 30 22 34 26 29 20 30 22 25 16
f Remote communication (Modbus®, BACnet® ).
Integral to AHU
0.13
Air Volume (m³/s)
43 36 39 31
42 35 38 30 40 32 35 25 37 29 32 23 33 24 28 19 28 19 23 14
50
44 36 40 32
42 33 37 28 39 30 34 25 35 26 30 21 30 22 25 16 24 16 18 9
42 34 37 28
40 31 34 25 36 28 30 21 33 24 26 17 27 19 20 11 22 14 17 8
40 32 35 26
38 29 32 23 34 26 27 18 30 22 23 14 26 18 21 13 26 18 25 17
38 30 32 23
36 28 30 20 33 24 26 17 30 21 25 17 29 20 29 21
32 24 29 21
CPF0-1/N/C
32 23 32 24
37 28 31 23 38 29 39 31 35 26 35 27
37 29 36 28 37 29 37 29
38 30 42 34
45 36 48 40
0.08
0.09
40 32 42 34
47 38 50 42
44 35 47 39
0 0
0.01
0.02
0.03
0.04
0.05
0.06
0.07
0.1
0.11
0.12
0.13
Air Volume (m³/s)
Filters
2b. Unit Configuration
C
G
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
4
Specify bespoke options for Colourfan products Page 31
Case Construction
Prewired/Fitted Controls
Thyristor Heater
Energy Efficient Fans
Speed Control
Humidity
Temperature
Our experience with controls also enables high levels of integration with Building Management Systems or existing systems, as well as matching to niche applications.
Casing Noise Breakout
Fan Voltage
Fan Speed rpm
125
250
500
1k
2k
4k
8k
100%
4501
66
53
47
48
38
41
54
47
47
39
43
35
90%
4050
63
58
49
45
36
37
33
34
29
21
35
27
80%
3600
61
56
47
42
33
34
30
30
26
17
33
24
70%
3150
59
54
44
39
30
31
26
27
23
14
30
22
60%
2700
56
51
42
36
27
28
23
24
20
11
27
19
50%
2250
52
47
39
34
23
24
19
20
18
9
24
16
Centre Frequency
63
125
250
500
1k
2k
4k
8k
Case Insertion Loss
-3
-5
-14
-19
-26
-22
-22
-15
63
1.4
NR @ 1m NR @ 3m dBA @ 1m dBA @ 3m
Plug & Play
Heat Recovery
Note: Independently acoustic tested to BS EN ISO 3744:2010.
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz) 63
125
250
500
1k
2k
4k
8k
Induct Loss
-6
-8
-12
-19
-28
-30
-24
-21
Dimensions mm
A
B
C
D
E
F
G
Weight kg
Plantroom
735
1200
340
635
240
50
25
75
Weatherproof
745
1200
365
635
240
50
25
85
Note: The silencer will add a maximum of 2 Pa to the external resistance.
F
Also see Specifications on pages 32-33
Silencer
CATVA0000/1200/STD
R
C G
D
B
A
D
A
Silencer Option
B
4
Demand Ventilation
2d. Noise and Silencer Data
E
1.2
Units can be adapted for higher specifications e.g. minimising noise breakout or for architectural aesthetics.
Loose Panel 37 29 31 22
35 27 29 21
1.0
As well as offering a wide range of standard Colourfan units VES is able to build bespoke versions for special applications and requirements.
f Demand ventilation.
100%
350
0.8
f Local control or user interface options.
450
400
0.6
Variety of control features:
2c. Controls
2a. Performance Curve
0.4
Air Volume (m³/s)
3
Specify your unit
1.5
Energy efficient low noise ErP compliant fans, robust case construction, low profile units, suitable for ceiling voids, plantrooms and roofs and can be configured for top or bottom access.
p26
E10 CA
Duties up to 2.8
m3/s
p24 9
Colourfan Twin Acoustic R
8
0.4
0.3
Air Volume (m³/s)
2
CAE0
0.2
0.1
0
1
p22
0
0
Choose duties up to 2.8 m3/s
p20
0 CAE
p18
06
3
p18
CAE07
p16
CAE06
p14
CAT
p12
5 CAT0
p10
04 CAT
p8
CAT0
p6
2 CAT0
50
F
Energy monitoring is an effective way of highlighting areas for potential savings, whilst providing a key indicator to ongoing energy consumption. Refer to pages 28-29.
5
Colour fan Twin Acoustic
duty up 1 Choose to 2.8 m /s
R
2 Specify your
3
Selection Data Unit Size 0 CAT0051-1 2a Performance Motor Size
Voltage
Fan Speed
Full Load Current
Speed Control
CAT0051-1
1 Phase
0.043 kW
230 VAC
4501 rpm
0.32 A
EC
WH Weatherproof D
E
C E
100% /l/ s
1.0
Unit Type
70%
200
0.6
150
60%
100
50%
CAT0 Plantroom Twin Extract
735
CAT0 Weatherproof Twin Extract
735
Dimensions mm C
D
E
F
G
700
340
635
240
50
25
700
365
635
240
50
25
0.4
0 0
0.01
0.02
0.03
0.04
0.05
0.06
0.07
0.08
0.2
0.09
0.1
0.3
0.11
0.12
0.13
400
350
90%
43 35 38 30
40 33 36 28
Resistance (Pa)
300 80%
250 70%
200
38 30 33 25 35 27 30 22
150
60%
34 26 29 20
100
50%
30 22 25 16
43 36 39 31
42 35 38 30 40 32 35 25 37 29 32 23 33 24 28 19 28 19 23 14
50
44 36 40 32
42 33 37 28 39 30 34 25 35 26 30 21 30 22 25 16 24 16 18 9
42 34 37 28
40 31 34 25 36 28 30 21 33 24 26 17 27 19 20 11 22 14 17 8
40 32 35 26
38 29 32 23 34 26 27 18 30 22 23 14 26 18 21 13 26 18 25 17
38 30 32 23
36 28 30 20 33 24 26 17 30 21 25 17 29 20 29 21
37 29 31 22
35 27 29 21 32 24 29 21 32 23 32 24
37 28 31 23 38 29 39 31 35 26 35 27
37 29 36 28
0.01
0.02
0.03
0.04
0.05
0.06
0.07
RT
RB
65
4
4
4
70
4
4
Unit Type
Integral to AHU
Loose panel
CAT0051-1
CPF0-1/P/C
CPF0-1/N/C
37 29 37 29
38 30 42 34
45 36 48 40
0.08
0.09
40 32 42 34
47 38 50 42
0.1
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Casing Noise Breakout
Fan Voltage
Fan Speed rpm
125
250
500
1k
2k
4k
8k
100%
4501
66
53
47
48
38
41
54
47
47
39
43
35
90%
4050
63
58
49
45
36
37
33
34
29
21
35
27
80%
3600
61
56
47
42
33
34
30
30
26
17
33
24
70%
3150
59
54
44
39
30
31
26
27
23
14
30
22
60%
2700
56
51
42
36
27
28
23
24
20
11
27
19
50%
2250
52
47
39
34
23
24
19
20
18
9
24
16
Centre Frequency
63
125
250
500
1k
2k
4k
8k
Case Insertion Loss
-3
-5
-14
-19
-26
-22
-22
-15
63
NR @ 1m NR @ 3m dBA @ 1m dBA @ 3m
Note: Independently acoustically tested to BS EN ISO 3744:2010.
44 35 47 39
0.11
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Silencer Option
0 0
LB
4
2d Noise and Silencer Data
450 100%
Configuration Options
LT
Note: If no control panel is purchased the unit will be supplied with a main isolator.
Note: SFP figures quoted at voltages tested in accordance with BS EN ISO 5801:2008, BS 848-1:2007.
Electrical input power (Watts)
Weight kg
W / LT / ISC CAT0051-1 / PH / EE WH RT CPSC RB LB
50
0.12
0.13
Air Volume (m³/s)
Note:
6
B
2c Controls
0.5
Air volume flow rate (litres/second)
Noise Performance Curves
=
A
0.7
SIZE 0 - CAT0051-1
0.8
250
NR levels are dependent upon environmental conditions. Tolerances: On flow rates: +/- 5% On acoustic power and pressure: Levels: +/- 3 dB By octave band: +/- 5 dB
Note: Data for design guidance only. For full details, outline drawings are available upon request.
Silencer
CATVA0000/1200
63
125
250
500
1k
2k
4k
8k
Induct Loss
-6
-8
-12
-19
-28
-30
-24
-21
Dimensions mm
A
B
C
D
E
F
G
Weight kg
Plantroom
735
1300
340
635
240
50
25
75
Weatherproof
735
1300
365
635
240
50
25
85
CATVA0000/1200/STD CATVA0000/1200/W/STD
Note: The silencer will add a maximum of 2 Pa to the external resistance.
E
C G
B
A
80%
F
F
0.9
D
300
B
A
B 1.1
D
1.2
90%
A
1.5
350
Air Volume (m³/s)
G
G
W
400
Resistance (Pa)
Duty Performance Curves
450
SFP
products Page 31
and efficiency Pages 28-30
CAT0051-1 / PH WH / EE / LT RB / ISC CPSC RT LB
C
Watts/litres /second
Specify bespoke
Configuration and Handing
PH Plantroom
Phase
for 4 options Colourfan
Add control
chosen unit
2b Unit Configuration
Size
for 3 packages performance
F
Note: Data for design guidance only. For full details, outline drawings are available upon request.
7
Colour fan Twin Acoustic
duty up 1 Choose to 2.8 m /s
R
2 Specify your
3
Selection Data Unit Size 1 CAT0141-1 2a Performance Motor Size
Voltage
Fan Speed
Full Load Current
Speed Control
CAT0141-1
1 Phase
0.12 kW
230 VAC
3490 rpm
0.68 A
EC
WH Weatherproof D
E
C
/s
1.5 W/l
1.2
Unit Type
1.1
60
1.0
%
250
0.9
200
50%
100
CAT1 Plantroom Twin Extract
880
CAT1 Weatherproof Twin Extract
880
Dimensions mm C
D
E
F
G
700
440
780
340
50
25
700
465
780
340
50
25
0.6
0 0
0.01
0.02
0.03
0.04
0.05
0.06
0.07
0.08
0.09
0.10
0.11
0.12
0.13
0.14
0.4 0.15 0.16
0.5 0.17 0.18
0.19
0.20
49 40 100% 90%
48 40 44 35
46 37
80
%
500
47 38 40 32
450 400
70
42 34 37 28
%
41 33 38 29
350 300
%
250
40 32 38 30
37 29 34 26
100 50
0.01
0.02
0.03
0.04
0.05
0.06
0.07
0.08
0.09
0.10
0.11
44 36 41 33
47 39 44 36
42 34 40 32
45 37 43 35
48 40 45 37
0.12
0.13
0.14
0.15
0.16
0.17
0.18
0.19
0.20
Air Volume (m³/s)
8
75
4
85
4
4
Integral to AHU
Loose panel
CAT0141-1
CPF0-1/P/C
CPF0-1/N/C
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Casing Noise Breakout
Fan Voltage
Fan Speed rpm
125
250
500
1k
2k
4k
8k
100%
3490
80
66
63
57
50
55
51
52
46
38
49
41
90%
3141
84
62
55
48
41
48
45
46
44
36
47
38
80%
2792
65
60
50
42
35
43
41
38
34
26
37
29
70%
2443
56
53
40
35
30
41
38
29
33
23
38
30
Centre Frequency
63
125
250
500
1k
2k
4k
8k
Case Insertion Loss
-3
-5
-14
-19
-26
-22
-22
-15
63
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
NR @ 1m NR @ 3m dBA @ 1m dBA @ 3m
Silencer
CATVA0100/1200
63
125
250
500
1k
2k
4k
8k
Induct Loss
-6
-8
-12
-19
-28
-30
-24
-21
Dimensions mm
A
B
C
D
E
F
G
Weight kg
Plantroom
880
1300
440
780
340
50
25
90
880
1300
465
780
340
50
25
105
CATVA0100/1200/STD
Weatherproof
CATVA0100/1200/W/STD
Note: The silencer will add a maximum of 5 Pa to the external resistance. Note:
RB
4
Unit Type
Silencer Option
0 0
RT
4
Note: Independently acoustically tested to BS EN ISO 3744:2010. 42 33 41 33
44 36 42 32
39 30 35 27
34 26 31 23
150
45 37 43 33
44 35 42 31
37 29 34 26
36 28 30 22
50%
200
45 37 43 33
43 35 39 29
40 31 33 25
38 30 33 23
60
46 37 42 31
44 35 37 29
LB
4
2d Noise and Silencer Data
600 550
Configuration Options
LT
Note: If no control panel is purchased the unit will be supplied with a main isolator.
Note: SFP figures quoted at voltages tested in accordance with BS EN ISO 5801:2008, BS 848-1:2007.
Electrical input power (Watts)
Weight kg
W / LT / ISC CAT0141-1 / PH / EE WH RT CPSC RB LB
0.7
50
Air volume flow rate (litres/second)
Noise Performance Curves
=
B
2c Controls
0.8
150
A
SIZE 1 - CAT0141-1
%
350 300
F
F
E
C G
B
A
70
D
400
Resistance (Pa)
SFP
B
A
B
Air Volume (m³/s)
Watts/litres /second
G
A
80 %
90%
D
500
E G
450
Resistance (Pa)
Duty Performance Curves
600
100%
products Page 31
and efficiency Pages 28-30
CAT0141-1 / PH WH / EE / LT RB / ISC CPSC RT LB
C
550
Specify bespoke
Configuration and Handing
PH Plantroom
Phase
for 4 options Colourfan
Add control
chosen unit
2b Unit Configuration
Size
for 3 packages performance
F
NR levels are dependent upon environmental conditions. Tolerances: On flow rates: +/- 5% On acoustic power and pressure: Levels: +/- 3 dB By octave band: +/- 5 dB
Note: Data for design guidance only. For full details, outline drawings are available upon request.
Note: Data for design guidance only. For full details, outline drawings are available upon request.
9
Colour fan Twin Acoustic
duty up 1 Choose to 2.8 m /s
R
2 Specify your
3
Selection Data Unit Size 2 CAT0242-1 2a Performance Motor Size
Voltage
Fan Speed
Full Load Current
Speed Control
CAT0242-1
1 Phase
0.14 kW
230 VAC
3240 rpm
0.78 A
EC
WH Weatherproof D
E
C E
B
%
400
80
% 1.5
1.2
300
70
%
1.1
Unit Type
1.0
A
B
CAT2 Plantroom Twin Extract
1010
CAT2 Weatherproof Twin Extract
1010
0.9 0.8
250
0.7
60
%
200
100
D
E
F
G
750
500
910
400
50
25
750
525
910
400
50
25
2c Controls
0.5
0
Configuration Options
LT
LB
RT
RB
90
4
4
4
4
105
4
4
0.02
0.04
0.06
0.08
0.10
0.12
0.14
0.16
0.18
0.20
0.22
0.3
0.24
0.26
0.4
0.28
0.30
0.32
10
0%
%
90
450 400
50 42 47 38
80
%
47 39 43 35
350 300
39 31 36 27
70
%
250
27 19 26 18
60
%
200
34 26 29 20 25 17 26 19
50%
150
47 39 42 34
44 36 38 29
28 20 26 18 26 18 26 18
100
42 34 36 27
28 20 26 18 28 20 27 19
38 30 35 27
31 23 29 22 29 21 30 22
36 28 37 29
34 26 38 30
37 29 39 31
0.04
0.06
0.08
0.10
0.12
0.14
0.16
0.18
CPF0-1/N/C
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Casing Noise Breakout
Fan Voltage
Fan Speed rpm
125
250
500
1k
2k
4k
8k
100%
3240
72
60
50
44
38
41
36
41
35
27
38
30
90%
2916
66
58
48
41
33
38
33
36
30
23
34
26
80%
2592
55
50
43
34
27
33
31
31
26
18
28
20
70%
2268
50
52
29
26
16
30
19
32
26
19
25
17
Centre Frequency
63
125
250
500
1k
2k
4k
8k
Case Insertion Loss
-3
-5
-14
-19
-26
-22
-22
-15
63
37 29 42 34
0.20
39 31 42 34
39 31 44 36
0.22
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Silencer Option
37 30 40 32
40 32 44 36
41 33 45 37
0 0.02
CPF0-1/P/C
NR @ 1m NR @ 3m dBA @ 1m dBA @ 3m
Note: Independently acoustically tested to BS EN ISO 3744:2010.
50
0
Loose panel
CAT0242-1
2d Noise and Silencer Data
550 500
Integral to AHU
Note: If no control panel is purchased the unit will be supplied with a main isolator.
Note: SFP figures quoted at voltages tested in accordance with BS EN ISO 5801:2008, BS 848-1:2007.
Electrical input power (Watts)
Unit Type
0.24
0.26
0.28
43 35 47 39 0.30
0.32
Air Volume (m³/s)
NR levels are dependent upon environmental conditions. Tolerances: On flow rates: +/- 5% On acoustic power and pressure: Levels: +/- 3 dB By octave band: +/- 5 dB
Note: Data for design guidance only. For full details, outline drawings are available upon request.
Silencer
CATVA0200/1200
63
125
250
500
1k
2k
4k
8k
Induct Loss
-6
-8
-12
-19
-28
-30
-24
-21
Dimensions mm
A
B
C
D
E
F
G
Weight kg
Plantroom
1010
1300
500
910
400
50
25
105
Weatherproof
1010
1300
525
910
400
50
25
120
CATVA0200/1200/STD CATVA0200/1200/W/STD
Note: The silencer will add a maximum of 3 Pa to the external resistance.
E
C G
B
A
0
Resistance (Pa)
Weight kg
W / LT / ISC CAT0242-1 / PH / EE WH RT CPSC RB LB
50
Note:
10
C
SIZE 2 - CAT0242-1
50%
150
Air volume flow rate (litres/second)
Noise Performance Curves
=
Dimensions mm
0.6
Air Volume (m³/s)
F
F
l/s
W/
D
Resistance (Pa)
350
B
A
0%
A
450
G
G
D
10
500
90
Duty Performance Curves
550
SFP
products Page 31
and efficiency Pages 28-30
CAT0242-1 / PH WH / EE / LT RB / ISC CPSC RT LB
C
Watts/litres /second
Specify bespoke
Configuration and Handing
PH Plantroom
Phase
for 4 options Colourfan
Add control
chosen unit
2b Unit Configuration
Size
for 3 packages performance
F
Note: Data for design guidance only. For full details, outline drawings are available upon request.
11
Colour fan Twin Acoustic
duty up 1 Choose to 2.8 m /s
R
2 Specify your
3
Selection Data Unit Size 3 CAT0343-1 2a Performance Motor Size
Voltage
Fan Speed
Full Load Current
Speed Control
CAT0343-1
1 Phase
0.23 kW
230 VAC
3290 rpm
1.2 A
EC
WH Weatherproof D
E
C E
%
80%
1.5
350
W
1.2
70%
Unit Type
B
CAT3 Plantroom Twin Extract
1020
CAT3 Weatherproof Twin Extract
1020
1.1 1.0
250
0.9
60%
C
D
E
F
G
850
550
920
450
50
25
850
575
920
450
50
25
2c Controls
0.7
0.6
50
0
0.02
0.04
0.06
0.08
0.10
0.12
0.14
0.16
0.18
0.20
0.22
0.24
0.26
0.3
0.28
0.30
0.4
0.32
0.34
0.5
0.36
0.38
0.4
550 100
%
Resistance (Pa)
53 45 49 41
90%
400
50 43 47 39
51 43 47 39
80%
48 40 44 36
350 300
70%
47 39 46 37
60%
38 30 36 27
250
43 35 40 31 32 24 25 16
200 150
50%
49 41 44 36 46 38 41 32 40 32 36 27 27 19 23 16
46 38 40 32 43 36 38 28 35 28 29 20 27 19 23 16
100
44 36 38 30 41 33 34 25 34 26 27 20 28 20 23 15
40 32 33 25 37 30 31 24 34 26 29 22 30 22 27 20
50 0
0
RT
RB
100
4
4
4
115
4
4
0.02
Unit Type
Integral to AHU
Loose panel
CAT0343-1
CPF0-1/P/C
CPF0-1/N/C
2d Noise and Silencer Data
600
450
LB
4
Note: If no control panel is purchased the unit will be supplied with a main isolator.
Note: SFP figures quoted at voltages tested in accordance with BS EN ISO 5801:2008, BS 848-1:2007.
Air volume flow rate (litres/second)
500
Configuration Options
LT
W / LT / ISC CAT0343-1 / PH / EE WH RT CPSC RB LB
100
0
Weight kg
SIZE 3 - CAT0343-1
50%
0.04
0.06
0.08
0.10
0.12
0.14
0.16
0.18
38 31 32 24
38 31 33 25
37 29 32 24
38 30 34 26
34 26 31 24
35 27 35 27
32 25 31 24
0.20
0.22
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Casing Noise Breakout
Fan Voltage
Fan Speed rpm
125
250
500
1k
2k
4k
8k
100%
3290
69
62
53
48
40
42
37
38
32
24
38
31
90%
2961
67
62
51
44
38
40
36
38
31
24
37
30
80%
2632
69
57
47
40
38
35
32
33
27
20
34
26
70%
2303
61
51
40
34
25
27
25
29
23
15
28
20
Centre Frequency
63
125
250
500
1k
2k
4k
8k
Case Insertion Loss
-3
-5
-14
-19
-26
-22
-22
-15
63
NR @ 1m NR @ 3m dBA @ 1m dBA @ 3m
Note: Independently acoustically tested to BS EN ISO 3744:2010. 39 31 35 27 38 30 36 28 37 29 39 31
0.24
0.26
39 32 38 30 41 33 39 31 41 33 39 31 40 32 42 34
0.28
0.30
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Silencer Option 42 34 44 36
0.32
44 36 46 38
0.34
0.36
0.38
0.40
Air Volume (m³/s)
Note:
12
Dimensions mm
0.8
200 150
A
NR levels are dependent upon environmental conditions. Tolerances: On flow rates: +/- 5% On acoustic power and pressure: Levels: +/- 3 dB By octave band: +/- 5 dB
Note: Data for design guidance only. For full details, outline drawings are available upon request.
Silencer
CATVA0300/1200
63
125
250
500
1k
2k
4k
8k
Induct Loss
-6
-8
-12
-19
-28
-30
-24
-21
Dimensions mm
A
B
C
D
E
F
G
Weight kg
Plantroom
1020
1300
550
920
450
50
25
115
1020
1300
575
920
450
50
25
125
CATVA0300/1200/STD
Weatherproof
CATVA0300/1200/W/STD
Note: The silencer will add a maximum of 3 Pa to the external resistance.
E
C G
B
A
300
F
F
/l/s
D
400
Electrical input power (Watts)
Noise Performance Curves
=
D
450
Air Volume (m³/s)
Watts/litres /second
B
A
B
90%
A
100
500
G
G
550
Resistance (Pa)
Duty Performance Curves
600
products Page 31
and efficiency Pages 28-30
CAT0343-1 / PH WH / EE / LT RB / ISC CPSC RT LB
C
SFP
Specify bespoke
Configuration and Handing
PH Plantroom
Phase
for 4 options Colourfan
Add control
chosen unit
2b Unit Configuration
Size
for 3 packages performance
F
Note: Data for design guidance only. For full details, outline drawings are available upon request.
13
Colour fan Twin Acoustic
duty up 1 Choose to 2.8 m /s
R
2 Specify your
3
Selection Data Unit Size 4 CAT0444-1 2a Performance Motor Size
Voltage
Fan Speed
Full Load Current
Speed Control
CAT0444-1
1 Phase
0.32 kW
230 VAC
2270 rpm
1.2 A
EC
WH Weatherproof D
E
C E
100
%
350
1.5 W/l/s 80%
Unit Type
1.2 1.1 1.0
70%
0.9
200
C
D
E
F
G
1100
950
600
1000
500
50
25
CAT4 Weatherproof Twin Extract
1100
950
725
1000
500
2c Controls
0.7
50%
100
CAT4 Plantroom Twin Extract
Dimensions mm
0.6
0 0
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.4
0.50
0.5
0.55
0.60
100
%
450
51 43 49 41 90%
48 40 47 38
Resistance (Pa)
350 80%
45 37 43 34
250
70%
42 34 40 31
200 60%
150
37 30 34 25
50%
100
50 42 47 39 47 39 45 36 43 36 41 32 39 31 35 26 33 26 28 19
49 41 45 37 45 38 42 33 40 33 36 27 35 27 29 21 29 21 22 14
50
46 39 41 33 42 34 37 28 37 29 30 22 31 24 25 17 29 21 21 13
43 35 36 28 39 31 33 25 35 27 29 21 32 25 26 18
0 0
RT
RB
120
4
4
4
150
4
4
Unit Type
Integral to AHU
Loose panel
CAT0444-1
CPF0-1/P/C
CPF0-1/N/C
2d Noise and Silencer Data
550
300
LB
4
Note: If no control panel is purchased the unit will be supplied with a main isolator.
Note: SFP figures quoted at voltages tested in accordance with BS EN ISO 5801:2008, BS 848-1:2007.
Air volume flow rate (litres/second)
400
Configuration Options
LT
W / LT / ISC CAT0444-1 / PH / EE WH RT CPSC RB LB
50
500
Weight kg
0.8
60%
150
B
SIZE 4 - CAT0444-1
250
A
0.05
0.10
0.15
0.20
0.25
0.30
41 33 35 28 38 30 33 25
36 28 30 22
41 33 35 28 39 31 33 25
34 27 29 21
38 30 33 25
0.35
0.40
Note:
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Casing Noise Breakout
Fan Voltage
Fan Speed rpm
125
250
500
1k
2k
4k
8k
100%
2270
72
67
59
53
43
46
41
39
36
28
43
35
90%
2043
73
67
57
50
40
43
38
36
37
28
42
34
80%
1816
68
62
53
46
37
39
34
32
30
22
37
29
70%
1589
67
61
51
42
33
35
29
26
29
21
35
27
60%
1362
68
60
47
38
29
31
24
20
28
19
33
26
Centre Frequency
63
125
250
500
1k
2k
4k
8k
Case Insertion Loss
-3
-5
-14
-19
-26
-22
-22
-15
63
NR @ 1m NR @ 3m dBA @ 1m dBA @ 3m
Note: Independently acoustically tested to BS EN ISO 3744:2010. 41 34 35 28 40 33 35 27
0.45
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Silencer Option 43 35 37 30
0.50
0.55
0.60
NR levels are dependent upon environmental conditions. Tolerances: On flow rates: +/- 5% On acoustic power and pressure: Levels: +/- 3 dB By octave band: +/- 5 dB
Note: Data for design guidance only. For full details, outline drawings are available upon request.
Silencer
CATVA0400/1200
63
125
250
500
1k
2k
4k
8k
Induct Loss
-6
-8
-12
-19
-28
-30
-24
-21
Dimensions mm
A
B
C
D
E
F
G
Weight kg
Plantroom
1100
1300
600
920
500
50
25
125
Weatherproof
1100
1300
725
725
500
CATVA0400/1200/STD CATVA0400/1200/W/STD
Note: The silencer will add a maximum of 8 Pa to the external resistance.
155
E
C G
B
A
300
F
F
Air Volume (m³/s)
14
D
90%
Electrical input power (Watts)
Noise Performance Curves
=
B
F
400
Air Volume (m³/s)
Watts/litres /second
A
B
450
A
G
D
500
Resistance (Pa)
Duty Performance Curves
550
products Page 31
and efficiency Pages 28-30
CAT0444-1 / PH WH / EE / LT RB / ISC CPSC RT LB
C
SFP
Specify bespoke
Configuration and Handing
PH Plantroom
Phase
for 4 options Colourfan
Add control
chosen unit
2b Unit Configuration
Size
for 3 packages performance
F
Note: Data for design guidance only. For full details, outline drawings are available upon request.
15
Colour fan Twin Acoustic
duty up 1 Choose to 2.8 m /s
R
2 Specify your
3
Selection Data Unit Size 5 CAT0545-1 2a Performance Motor Size
Voltage
Fan Speed
Full Load Current
Speed Control
CAT0545-1
1 Phase
0.4 kW
230 VAC
2010 rpm
1.5 A
EC
WH Weatherproof D
C
G
B 1.0 0.9
F
80%
Unit Type
300 70%
0.6
200 60%
150
C
0
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.2
0.55
0.60
0.65
0.70
0.3
0.75
0.80
0.85
1050
650
1165
550
CAT5 Weatherproof Twin Extract
1265 1415 1050
825
1165
550
52 44 51 42
500
51 43 50 41
450 90%
400
49 41 48 39
49 41 46 37
48 40 46 37
350 80%
46 38 44 36
300 250
70%
200
45 37 42 33
43 35 41 32
60%
32 24 34 26
50
36 28 38 30
43 36 38 30
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
Note:
25
Configuration Options
LT
LB
RT
RB
140
4
4
4
4
185
4
4
CAT0545-1 / PH / EE W / LT / ISC WH RT CPSC RB LB
Unit Type
Integral to AHU
Loose panel
CAT0545-1
CPF0-1/P/C
CPF0-1/N/C
43 35 41 34
40 32 40 33
0.55
0.60
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Casing Noise Breakout
Fan Voltage
Fan Speed rpm
125
250
500
1k
2k
4k
8k
100%
2010
70
62
56
51
44
46
41
44
38
30
41
33
90%
1809
68
61
52
48
40
43
38
42
36
28
38
30
80%
1608
66
59
49
45
36
40
34
38
32
24
35
28
70%
1407
63
56
46
41
33
36
30
35
29
21
32
24
60%
1206
64
56
44
38
28
31
26
23
24
15
30
23
Centre Frequency
63
125
250
500
1k
2k
4k
8k
Case Insertion Loss
-3
-5
-14
-19
-26
-22
-22
-15
63
0.65
0.70
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Silencer Option
0 0
75
Weight kg
NR @ 1m NR @ 3m dBA @ 1m dBA @ 3m
Note: Independently acoustically tested to BS EN ISO 3744:2010.
40 32 38 31
36 28 36 28
32 24 32 24
29 22 22 14
41 33 38 30
38 30 36 28
35 28 32 24
33 25 26 18
34 26 28 19
50%
100
39 31 33 24
40 32 36 28
39 31 34 25
150
40 33 37 29
39 31 34 26
G
2d Noise and Silencer Data
44 36 39 30
44 37 40 31
F
Note: If no control panel is purchased the unit will be supplied with a main isolator.
550 100%
E
1265
0.90
Note: SFP figures quoted at voltages tested in accordance with BS EN ISO 5801:2008, BS 848-1:2007.
Electrical input power (Watts)
D
CAT5 Plantroom Twin Extract
0.4
0
0.75
0.80
0.85
0.90
Air Volume (m³/s)
16
B
2c Controls
0.5
50%
Air volume flow rate (litres/second)
Noise Performance Curves
=
Dimensions mm
AA
50
Resistance (Pa)
SFP
A
0.7
SIZE 5 - CAT0545-1
0.8
NR levels are dependent upon environmental conditions. Tolerances: On flow rates: +/- 5% On acoustic power and pressure: Levels: +/- 3 dB By octave band: +/- 5 dB
Note: Data for design guidance only. For full details, outline drawings are available upon request.
Silencer
CATVA0500/1200
63
125
250
500
1k
2k
4k
8k
Induct Loss
-6
-8
-12
-19
-28
-30
-24
-21
B
C
D
E
F
G
Weight kg
1265
1300
650
1165
550
75
25
140
1265
1415 1300
825
1165
550
Dimensions mm
A
Plantroom
Weatherproof
CATVA0500/1200/STD CATVA0500/1200/W/STD
AA
Note: The silencer will add a maximum of 11 Pa to the external resistance.
180
E
C G
B
A
350
Air Volume (m³/s)
Watts/litres /second
B
F
D
1.1
A
1.2
90%
A
/l/s
1.5 W
450
D
500
Resistance (Pa)
Duty Performance Curves
E
100%
100
AA
E
550
250
products Page 31
and efficiency Pages 28-30
CAT0545-1 / PH WH / EE / LT RB / ISC CPSC RT LB
C
400
Specify bespoke
Configuration and Handing
PH Plantroom
Phase
for 4 options Colourfan
Add control
chosen unit
2b Unit Configuration
Size
for 3 packages performance
F
Note: Data for design guidance only. For full details, outline drawings are available upon request.
17
Colour fan Twin Acoustic
duty up 1 Choose to 2.8 m /s
R
2 Specify your
3
Selection Data Unit Size 6 CAT0646-1 2a Performance Motor Size
Voltage
Fan Speed
Full Load Current
Speed Control
CAT0646-1
1 Phase
0.35 kW
230 VAC
1590 rpm
1.3 A
EC
WH Weatherproof D
C
G
B
0.9
F
0.7
70%
100
50%
Unit Type
0.6
0.5
0 0
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.55
0.60
0.65
0.2
0.70
0.75
0.80
0.85
0.3
0.90
0.95
Electrical input power (Watts)
49 42 49 40
400
350
90%
49 42 49 40
46 39 44 35
46 39 44 35
300 80%
43 36 39 31
250 70%
200
150
100
38 30 31 23
38 31 34 27
35 28 31 24 34 26 27 18
32 25 26 17
32 25 26 17
50%
39 31 32 25
38 30 32 24
38 30 33 24
37 29 34 24
43 35 38 30
43 35 39 31
43 35 39 31
40 32 36 27
60%
46 39 44 35
27 19 19 11
1265
1210
730
1165
630
CAT6 Weatherproof Twin Extract
1265 1415 1210
905
1165
630
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.55
Note:
G
75
25
Weight kg
Configuration Options
LT
LB
RT
RB
165
4
4
4
4
220
4
4
W / LT / ISC CAT0646-1 / PH / EE WH RT CPSC RB LB
Unit Type
Integral to AHU
Loose panel
CAT0646-1
CPF0-1/P/C
CPF0-1/N/C
0.60
0.65
0.70
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Casing Noise Breakout
Fan Voltage
Fan Speed rpm
125
250
500
1k
2k
4k
8k
100%
1590
69
64
53
49
41
42
36
43
36
29
39
31
90%
1431
66
60
50
46
38
39
33
40
33
26
36
28
80%
1272
64
58
47
42
34
36
31
32
26
18
32
25
70%
1113
63
54
45
39
30
32
29
23
21
14
29
22
60%
954
66
54
44
35
27
28
20
14
21
12
29
22
Centre Frequency
63
125
250
500
1k
2k
4k
8k
Case Insertion Loss
-3
-5
-14
-19
-26
-22
-22
-15
63
0.75
0.80
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Silencer Option
42 35 41 34
0 0
F
NR @ 1m NR @ 3m dBA @ 1m dBA @ 3m
Note: Independently acoustically tested to BS EN ISO 3744:2010.
39 32 38 31
36 28 35 28
31 24 27 19
27 20 22 15
50
40 32 38 31
37 29 36 29
33 26 29 22
29 22 21 14
E
2d Noise and Silencer Data
450 100%
D
Note: If no control panel is purchased the unit will be supplied with a main isolator.
Note: SFP figures quoted at voltages tested in accordance with BS EN ISO 5801:2008, BS 848-1:2007.
0.85
0.90
0.95
Air Volume (m³/s)
18
C
CAT6 Plantroom Twin Extract
1.0
Air volume flow rate (litres/second)
Noise Performance Curves
=
B
50
Resistance (Pa)
SFP
Dimensions mm
AA
2c Controls
0.4
Air Volume (m³/s)
Watts/litres /second
A
SIZE 6 - CAT0646-1
80%
250
NR levels are dependent upon environmental conditions. Tolerances: On flow rates: +/- 5% On acoustic power and pressure: Levels: +/- 3 dB By octave band: +/- 5 dB
Note: Data for design guidance only. For full details, outline drawings are available upon request.
1.0
Silencer
CATVA0600/1200
63
125
250
500
1k
2k
4k
8k
Induct Loss
-6
-8
-12
-19
-28
-30
-24
-21
B
C
D
E
F
G
Weight kg
1265
1300
730
1165
630
75
25
150
1265
1415 1300
905
1165
630
Dimensions mm
A
Plantroom
Weatherproof
CATVA0600/1200/STD CATVA0600/1200/W/STD
AA
Note: The silencer will add a maximum of 12 Pa to the external resistance.
190
E
C G
B
A
300
60%
B
F
0.8
A
1.0
90%
D
1.2 1.1
A
1.5
l/s W/
D
400
Resistance (Pa)
Duty Performance Curves
E
100%
150
AA
E
450
200
products Page 31
and efficiency Pages 28-30
CAT0646-1 / PH WH / EE / LT RB / ISC CPSC RT LB
C
350
Specify bespoke
Configuration and Handing
PH Plantroom
Phase
for 4 options Colourfan
Add control
chosen unit
2b Unit Configuration
Size
for 3 packages performance
F
Note: Data for design guidance only. For full details, outline drawings are available upon request.
19
Colour fan Twin Acoustic
duty up 1 Choose to 2.8 m /s
R
Selection Data Unit Size 7 CAT0747-3 2a Performance Motor Size
Voltage
Fan Speed
Full Load Current
Speed Control
CAT0747-3
3 Phase
1.4 kW
400 VAC
2100 rpm
1.9 A
EC E
C
A
D
B
F
700
F
1.5 W/l/s
Unit Type
A
1.2
500 70%
1.1
400 1.0
60%
Dimensions mm
AA
B
C
1725
1390
820
1625
720
CAT7 Weatherproof Twin Extract
1725 1875 1390
995
1625
720
0.8
0.7
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.3
0.5
1.4
1.5
0.6 1.6
1.7
1.8
Air Volume (m³/s)
F
G
75
25
Weight kg
Configuration Options
LT
LB
RT
RB
230
4
4
4
4
300
4
4
W / LT / ISC CAT0747-3 / PH / EE WH RT CPSC RB LB
100
0.4 1.2
E
CAT7 Plantroom Twin Extract
2c Controls
0.9
50%
D
Unit Type
Integral to AHU
Loose panel
CAT0747-3
CPF0-3/P/C
CPF0-3/N/C
SIZE 7 - CAT0747-3
80%
0
A
B
90%
200
AA
G
900
Resistance (Pa)
Duty Performance Curves
WH Weatherproof
E
100%
300
products Page 31
CAT0747-3 / PH WH / EE / LT RB / ISC CPSC RT LB
C
600
Specify bespoke
and efficiency Pages 28-30
D
1000
for 4 options Colourfan
Add control
Configuration and Handing
PH Plantroom
Phase
for 3 packages performance
chosen unit
2b Unit Configuration
Size
800
2 Specify your
3
Note: If no control panel is purchased the unit will be supplied with a main isolator.
Note: SFP figures quoted at voltages tested in accordance with BS EN ISO 5801:2008, BS 848-1:2007.
1000 100%
59 52 60 51
900 800
58 51 57 49
55 48 55 47
90%
53 45 52 43
80%
600
70%
50 43 49 41
60%
300
47 40 42 34
48 41 43 35
45 37 39 31 43 36 38 29
42 35 38 29
43 35 38 29
50%
200
48 41 43 35
48 41 45 36
47 40 45 36
46 38 42 34
53 46 49 41
52 45 50 42
52 44 50 42
500 400
56 49 55 47
55 47 54 46
700
37 29 31 23
46 38 40 33
42 35 37 30
39 31 34 27
49 42 44 37
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
Casing Noise Breakout
Fan Speed rpm
125
250
500
1k
2k
4k
8k
100%
2100
76
69
65
60
52
52
46
47
42
35
47
40
90%
1890
74
68
63
57
49
48
44
45
40
32
46
39
80%
1680
72
67
58
54
46
44
40
43
36
29
42
35
70%
1470
70
65
55
49
41
40
36
40
33
26
39
32
60%
1260
71
64
54
46
37
37
32
34
32
24
38
30
Centre Frequency
63
125
250
500
1k
2k
4k
8k
Case Insertion Loss
-3
-5
-14
-19
-26
-22
-22
-15
63
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Silencer Option 51 44 47 40
0 0
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Fan Voltage
NR @ 1m NR @ 3m dBA @ 1m dBA @ 3m
Note: Independently acoustically tested to BS EN ISO 3744:2010.
49 41 44 37
45 37 40 33
40 33 39 32
37 30 35 28
100
1.5
1.6
1.7
Air Volume (m³/s)
Note:
20
2d Noise and Silencer Data
NR levels are dependent upon environmental conditions. Tolerances: On flow rates: +/- 5% On acoustic power and pressure: Levels: +/- 3 dB By octave band: +/- 5 dB
Note: Data for design guidance only. For full details, outline drawings are available upon request.
1.8
Silencer
CATVA0700/1200
63
125
250
500
1k
2k
4k
8k
Induct Loss
-6
-8
-12
-19
-28
-30
-24
-21
Dimensions mm
A
Plantroom
1725
Weatherproof
1725
CATVA0700/1200/STD CATVA0700/1200/W/STD
C
D
E
F
G
Weight kg
1300
820
1625
720
75
25
200
1875 1300
995
1625
720
AA
B
Note: The silencer will add a maximum of 18 Pa to the external resistance.
250
E
C G
B
A
Electrical input power (Watts) Air volume flow rate (litres/second)
Noise Performance Curves
=
D
Resistance (Pa)
SFP
Watts/litres /second
F
Note: Data for design guidance only. For full details, outline drawings are available upon request.
21
Colour fan Twin Acoustic
duty up 1 Choose to 2.8 m /s
R
Selection Data Unit Size 8 CAT0848-3 2a Performance Motor Size
Voltage
Fan Speed
Full Load Current
Speed Control
CAT0848-3
3 Phase
1.45 kW
400 VAC
1800 rpm
2A
EC
Unit Type
1.2 1.1
70%
1.0
400
A
Dimensions mm
AA
B
C
1570
CAT8 Plantroom Twin Extract
1815
910
1715
810
CAT8 Weatherproof Twin Extract
1815 1965 1570 1085
1715
810
2c Controls
0.8
0.7
0.6
0 0.2
0.4
0.6
0.8
1.0
1.2
0.3
1.4
1.6
0.4
1.8
0.5
2.0
2.2
500
70%
400 60%
300
55 48 54 46
53 46 52 44
50 43 47 39 45 38 43 34
50%
58 52 59 51 55 49 55 47
53 45 51 43 49 42 46 37 42 35 37 28
200
57 50 56 49 54 47 52 44
50 43 47 39 45 38 41 33 38 31 33 25
55 48 52 44
51 44 47 39
46 39 42 34 42 35 37 30 37 30 33 25
52 45 48 40 48 41 43 36
50 43 46 38 47 40 42 35
44 37 39 32 41 34 36 29 39 32 35 28
100
44 37 39 32 43 36 38 31
50 43 47 39 47 41 42 35
47 39 42 34
0.2
0.4
0.6
0.8
1.0
51 44 47 39 49 43 44 37
49 42 43 36
0 0
LB
RT
RB
280
4
4
4
4
370
4
4
Unit Type
Integral to AHU
Loose panel
CAT0848-3
CPF0-3/P/C
CPF0-3/N/C
1.2
1.4
1.6
Note:
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Casing Noise Breakout
Fan Voltage
Fan Speed rpm
125
250
500
1k
2k
4k
8k
100%
1800
78
74
70
62
53
50
45
46
47
39
50
43
90%
1620
76
73
66
59
50
46
41
44
42
35
47
40
80%
1440
75
70
63
55
45
42
37
42
39
32
44
37
70%
1260
74
67
60
51
41
39
34
37
36
29
41
34
60%
1080
71
61
57
44
34
35
29
25
33
25
37
30
Centre Frequency
63
125
250
500
1k
2k
4k
8k
Case Insertion Loss
-3
-5
-14
-19
-26
-22
-22
-15
63
NR @ 1m NR @ 3m dBA @ 1m dBA @ 3m
Note: Independently acoustically tested to BS EN ISO 3744:2010. 53 46 48 41
51 44 46 38 1.8
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Silencer Option 54 47 49 42 2.0
2.2
NR levels are dependent upon environmental conditions. Tolerances: On flow rates: +/- 5% On acoustic power and pressure: Levels: +/- 3 dB By octave band: +/- 5 dB
Note: Data for design guidance only. For full details, outline drawings are available upon request.
Silencer
CATVA0800/1200
63
125
250
500
1k
2k
4k
8k
Induct Loss
-6
-8
-12
-19
-28
-30
-24
-21
Dimensions mm
A
Plantroom
1815
Weatherproof
1815
CATVA0800/1200/STD CATVA0800/1200/W/STD
C
D
E
F
G
Weight kg
1300
910
1715
810
75
25
220
1965 1300
1085
1715
810
AA
B
Note: The silencer will add a maximum of 12 Pa to the external resistance.
280
E
C G
B
A
80%
25
Configuration Options
LT
D
58 51 58 50
700 600
75
Weight kg
2d Noise and Silencer Data
1000
90%
G
Note: If no control panel is purchased the unit will be supplied with a main isolator.
Note: SFP figures quoted at voltages tested in accordance with BS EN ISO 5801:2008, BS 848-1:2007.
Air volume flow rate (litres/second)
800
F
W / LT / ISC CAT0848-3 / PH / EE WH RT CPSC RB LB
100
900
E
SIZE 8 - CAT0848-3
50%
200
100%
D
0.9
300
0
A
F
Air Volume (m³/s)
22
D
/s
1.5 W/l
60%
Resistance (Pa)
=
B
F
80%
Electrical input power (Watts)
Noise Performance Curves
Watts/litres /second
C
A
B
700
Resistance (Pa)
Duty Performance Curves
E
90%
500
AA
G
Air Volume (m³/s)
SFP
WH Weatherproof
E
100%
600
products Page 31
CAT0848-3 / PH WH / EE / LT RB / ISC CPSC RT LB
C
800
Specify bespoke
and efficiency Pages 28-30
D
1000
for 4 options Colourfan
Add control
Configuration and Handing
PH Plantroom
Phase
for 3 packages performance
chosen unit
2b Unit Configuration
Size
900
2 Specify your
3
F
Note: Data for design guidance only. For full details, outline drawings are available upon request.
23
Colour fan Twin Acoustic
duty up 1 Choose to 2.8 m /s
R
Selection Data Unit Size 9 CAT0949-3 2a Performance Motor Size
Voltage
Fan Speed
Full Load Current
Speed Control
CAT0949-3
3 Phase
1.25 kW
400 VAC
1400 rpm
1.65 A
EC
400
Unit Type
0.9
70%
0.8
300
0.7
60%
200
B
C
1750 1000
1695
900
CAT9 Weatherproof Twin Extract
1795 1945 1750 1175
1695
900
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
0.3 2.0
2.2
0.4
2.4
650
53 45
600
90%
550
52 45 49 41
55 48 54 46 53 46 51 43
500 450
80%
400 350
70%
300 250
60%
200
49 43 48 39
47 40 45 37 43 36 41 33
49 42 47 38
45 38 43 34 42 35 39 30
54 47 53 45 51 44 49 41
47 40 43 35 43 36 38 29 38 31 31 23
50%
150
53 46 51 43 49 42 45 37
44 37 39 31 39 33 34 26 34 27 28 21
100
50 43 46 38 46 39 42 34
42 35 37 29 38 31 33 25 34 27 28 21
48 41 44 36 43 37 38 31
41 34 36 28
37 30 35 29
50
46 39 41 33 44 37 39 31
38 31 34 28
41 34 37 31
41 34 39 32
0.2
0.4
0.6
0.8
1.0
1.2
46 39 42 34 44 37 39 32
44 37 40 33 43 36 43 36
0 0
1.4
1.6
47 40 43 35
LB
RT
RB
330
4
4
4
4
420
4
4
Unit Type
Integral to AHU
Loose panel
CAT0949-3
CPF0-3/P/C
CPF0-3/N/C
47 40 43 35
46 39 44 37 1.8
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Casing Noise Breakout
Fan Voltage
Fan Speed rpm
125
250
500
1k
2k
4k
8k
100%
1400
73
74
65
59
49
46
42
48
43
35
47
40
90%
1260
71
72
63
57
47
44
41
48
41
33
45
38
80%
1120
71
68
60
52
41
40
34
45
37
31
41
34
70%
980
68
65
57
49
37
38
30
42
34
28
38
31
60%
840
71
61
53
44
33
34
25
23
28
21
35
28
Centre Frequency
63
125
250
500
1k
2k
4k
8k
Case Insertion Loss
-3
-5
-14
-19
-26
-22
-22
-15
63
NR @ 1m NR @ 3m dBA @ 1m dBA @ 3m
Note: Independently acoustically tested to BS EN ISO 3744:2010.
48 41 45 38
2.0
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Silencer Option
49 42 45 37
2.2
Air Volume (m³/s)
Note:
25
Configuration Options
LT
2d Noise and Silencer Data
700 100% 55 48
75
Weight kg
Note: If no control panel is purchased the unit will be supplied with a main isolator.
Note: SFP figures quoted at voltages tested in accordance with BS EN ISO 5801:2008, BS 848-1:2007.
Electrical input power (Watts)
G
2.4
NR levels are dependent upon environmental conditions. Tolerances: On flow rates: +/- 5% On acoustic power and pressure: Levels: +/- 3 dB By octave band: +/- 5 dB
Note: Data for design guidance only. For full details, outline drawings are available upon request.
Silencer
CATVA0900/1500
63
125
250
500
1k
2k
4k
8k
Induct Loss
-6
-8
-12
-19
-28
-30
-24
-21
Dimensions mm
A
Plantroom
1795
Weatherproof
1795
CATVA0900/1500/W/STD
C
D
E
F
G
Weight kg
1600
1000
1695
900
75
25
290
1945 1600
1175
1695
900
AA
B
Note: The silencer will add a maximum of 12 Pa to the external resistance.
350
E
C G
B
A
0
F
W / LT / ISC CAT0949-3 / PH / EE WH RT CPSC RB LB
0.5
0
E
1795
100 50
D
CAT9 Plantroom Twin Extract
CATVA0900/1500/STD
24
Dimensions mm
AA
2c Controls
0.6
50%
A
SIZE 9 - CAT0949-3
1.0
Air volume flow rate (litres/second)
Noise Performance Curves
=
D F
1.1
80%
150
B
F
D
500
Resistance (Pa)
A
B 1.2
250
C
A
/l/s
550
Resistance (Pa)
Duty Performance Curves SFP
E
1.5 W
90%
350
AA
G
Air Volume (m³/s)
Watts/litres /second
WH Weatherproof
E
100%
450
products Page 31
CAT0949-3 / PH WH / EE / LT RB / ISC CPSC RT LB
C
600
Specify bespoke
and efficiency Pages 28-30
D
700
for 4 options Colourfan
Add control
Configuration and Handing
PH Plantroom
Phase
for 3 packages performance
chosen unit
2b Unit Configuration
Size
650
2 Specify your
3
F
Note: Data for design guidance only. For full details, outline drawings are available upon request.
25
Colour fan Twin Acoustic
duty up 1 Choose to 2.8 m /s
R
Selection Data Unit Size 10 CAT10410-3 2a Performance Motor Size
Voltage
Fan Speed
Full Load Current
Speed Control
CAT10410-3
3 Phase
1.5 kW
400 VAC
1230 rpm
2.1 A
EC E
A
B
1.2
F
1.1
500
1.0
F 0.9
80%
Unit Type
400 0.8
350 70%
0.7
60%
A
Dimensions mm
AA
B
C
D
E
CAT10 Plantroom Twin Extract
1980
1950 1100
1880
1000
CAT10 Weatherproof Twin Extract
1980 2130 1950 1275
1880
1000
F
G
75
25
Weight kg
Configuration Options
LT
LB
RT
RB
390
4
4
4
4
490
4
4
2c Controls
50%
0.5
100
W / LT / ISC CAT10410-3 / PH / EE WH RT CPSC RB LB
50 0 0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
2.2
0.3
2.4
2.6
2.8
0.4
3.0
Air Volume (m³/s)
SIZE 10 - CAT10410-3
0.6
200 150
B
D
90%
250
C
A
1.5 W
300
AA
G
/l/s
600
Resistance (Pa)
Duty Performance Curves
WH Weatherproof
E
100%
450
products Page 31
CAT10410-3 / PH WH / EE / LT RB / ISC CPSC RT LB
C
550
Specify bespoke
and efficiency Pages 28-30
D
700
for 4 options Colourfan
Add control
Configuration and Handing
PH Plantroom
Phase
for 3 packages performance
chosen unit
2b Unit Configuration
Size
650
2 Specify your
3
Unit Type
Integral to AHU
Loose panel
CAT10410-3
CPF0-3/P/C
CPF0-3/N/C
Note: If no control panel is purchased the unit will be supplied with a main isolator.
Note: SFP figures quoted at voltages tested in accordance with BS EN ISO 5801:2008, BS 848-1:2007.
700 650
100% 54 48
52 44
600 90% 51 45
550
50 41
500 450
80% 49 42
47 39
400 350
70% 46 39
300
45 36
250
60% 43 36
41 33
200
55 48 53 45 52 46 51 43
50 43 50 41
47 40 46 38 43 37 42 34
55 48 53 45 52 45 51 43
49 42 47 39
45 39 44 35 40 33 37 29
50%
150
54 48 53 45 51 44 49 40
47 40 44 35
42 35 38 30 36 29 31 22
53 46 50 43 48 42 45 37
44 38 40 32 39 32 33 26 33 26 25 18
100
51 44 48 40 46 40 42 35
42 35 38 30 37 30 30 22 32 25 24 16
50
49 42 46 38 44 37 40 32
40 33 36 28 36 29 29 23 34 27 27 21
0 0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
47 40 44 36 43 36 39 31
46 39 42 35
43 36 39 31
44 37 40 32
39 33 34 27
37 31 35 28 37 30 34 27
1.6
46 40 44 36
46 39 42 35
41 34 37 30
40 33 39 32
1.8
47 40 45 37
43 37 40 33
48 41 46 38
47 41 45 38 45 39 44 37
2.0
2.2
Casing Noise Breakout
Fan Speed rpm
125
250
500
1k
2k
4k
8k
100%
1230
74
76
64
58
47
44
39
48
45
37
47
40
90%
1107
72
71
61
54
43
40
35
47
39
32
43
36
80%
984
71
68
58
50
40
38
32
44
36
29
40
33
70%
861
71
62
54
46
36
35
32
36
29
22
36
29
60%
738
68
58
49
41
32
30
30
24
24
16
32
25
Centre Frequency
63
125
250
500
1k
2k
4k
8k
Case Insertion Loss
-3
-5
-14
-19
-26
-22
-22
-15
63
2.6
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Silencer Option
50 43 46 38
49 42 48 41
2.4
Sound Spectrum dB re 10-12 W PWL Centre Frequency (Hz)
Fan Voltage
NR @ 1m NR @ 3m dBA @ 1m dBA @ 3m
Note: Independently acoustically tested to BS EN ISO 3744:2010.
51 44 48 40
2.8
Air Volume (m³/s)
Note:
26
2d Noise and Silencer Data
NR levels are dependent upon environmental conditions. Tolerances: On flow rates: +/- 5% On acoustic power and pressure: Levels: +/- 3 dB By octave band: +/- 5 dB
Note: Data for design guidance only. For full details, outline drawings are available upon request.
3.0
Silencer
CATVA1000/1500
63
125
250
500
1k
2k
4k
8k
Induct Loss
-6
-8
-12
-19
-28
-30
-24
-21
Dimensions mm
A
Plantroom
1980
Weatherproof
1980
CATVA1000/1500/STD CATVA1000/1500/W/STD
C
D
E
F
G
Weight kg
1600
1100
1880
1000
75
25
330
2130 1600
1275
1880
1000
AA
B
Note: The silencer will add a maximum of 17 Pa to the external resistance.
390
E
C G
B
A
Electrical input power (Watts) Air volume flow rate (litres/second)
Noise Performance Curves
=
D
Resistance (Pa)
SFP
Watts/litres /second
F
Note: Data for design guidance only. For full details, outline drawings are available upon request.
27
Colour fan Twin Acoustic R
Controls packages for performance and efficiency
Save energy and costs with BlueSense Controls BlueSense philosophy combines intelligent control technologies with energy saving products, services and engineering expertise. BlueSense helps meet energy reduction commitments by optimising the equipment performance, improving energy efficiency, saving money and increasing equipment life expectancy.
2 Specify your
3
BlueSense Energy Savings
Demand ventilation solutions.
TM
duty up 1 Choose to 2.8 m /s
for 3 packages performance
for 4 options Colourfan
Specify bespoke
Add control
chosen unit
products Page 31
and efficiency Pages 28-30
Energy comparisons for the Colourfan range illustrate how they reduce energy demands whilst improving the environment and saving money. The example below is a typical office building, with an occupancy variation that results in an average 40% reduction in airflow requirement for 40% of the working day. The ventilation system operates from 8am till 6pm Monday to Friday, with a ventilation rate of 0.2 m3/s at 100 Pa.
Energy Chart Life Cycle Costs
140 Colourfan BlueSense Colourfan
120
BlueSense can be applied to a variety of projects and applications, providing efficient solutions whilst supporting design for best practice and sustainability.
100
80
BlueSense Features
60
f Inbuilt intelligent controls technology f Optimises performance and efficiency
40
20
f Demand ventilation control improves air quality, reducing energy consumption and lowering operating costs
0
f Combined CO2 and VOC sensing technology with energy efficient speed control f Extending equipment life expectancy and reducing maintenance
JUL
AUG
SEP
OCT
NOV
DEC
JAN
FEB
MAR
APR
MAY
JUN
complian t
Comparison of Unit Costs Over 10 Years
f Short term payback on capital expenditure f Extended warranty
Operating Capital 100%
Total Cost %
80%
60%
40%
20%
0%
Colourfan
The heating requirement has been based upon the UK heating profile for an air temperature setpoint of 18.5 ºC; the same heater size has been used for all comparisons.
Colourfan BlueSense All products in the Colourfan range can form part of a BlueSense energy saving package. Specify BlueSense to ensure Extract or Twin Extract units are optimised with pre-wired controls, energy efficient speed controller and air quality sensor. All of these work in unison, reducing energy consumption and saving money.
Colourfan BlueSense
Conclusion
Combining VES products with BlueSense technology will reduce the impact to the environment, minimise overall life cycle costs and payback period. VES is experienced at discussing energy requirements with clients, our knowledge and technology can help to identify areas where savings can be made. VES can provide assistance for both new and existing buildings.
A BlueSense Example
BlueSense Includes an Extended Warranty
= Colourfan Acoustic Unit with Integral Controls 28
EC fan - with full control
Sensor options
f 3 years with BlueSense packages. f 5 years with BlueSense package and Post Installation Commissioning. The sign of energy saving products, services and expertise
Please quote BlueSense with your order or contact our specialist sales team for further information. Call +44 (0)8448 15 60 60 or Email
[email protected]
29
Colour fan Twin Acoustic
duty up 1 Choose to 2.8 m /s
R
R
Colourfan Twin Controls Introduction
VES designs and manufactures all controls systems entirely in-house, this advantage ensures that the most efficient, lowest cost, highest quality packages are available. The CPF Twin Controls provide automatic change over upon fan failure to ensure continuous extract ventilation, including a time dependent duty share function and additional features to suit advanced applications. e.g. constant pressure and humidity control.
2 Specify your
3
chosen unit
for 3 packages performance
for 4 options Colourfan
Specify bespoke
Add control
products Page 31
and efficiency Pages 28-30
Bespoke Solutions As well as offering a wide range of standard Colourfan units VES are able to build bespoke versions for special applications and requirements. Units can be adapted for higher specifications to address challenging locations and applications. Our experience with controls also enables high levels of integration with Building Management Systems or existing solutions, as well as matching to niche applications. With VES you really get the full package without needing to mix and match suppliers.
Features
Bespoke Options:
f Single or three phase, twin extract fan control f Auto changer over upon fan failure, detected by fitted and pre-wired airflow pressure switch
arger air volumes f L f Dual outlet spigots
f Aesthetic requirements and paint colour finishes f Saline environment
f Time dependent 12 Hrs duty share, with memory retention f Optional remote status indicator, pressure, temperature and humidity functions
f Extreme temperatures
f BlueSense energy saving package for demand ventilation control, complete with fully integrated pre-wired control panel, energy efficient speed control and air quality sensor
Air Quality Sensor
Specialist Site Services VES operates a Specialist Site Services division, which is a market leader in the repair and refurbishment of any make or model of air handling equipment.
Selection Matrix
CPF
Power supply
230 VAC 50 Hz or 400 VAC 50 Hz
3
Twin extract fan
230 VAC 50 Hz or 400 VAC 50 Hz
3
Auto-change-over and duty share
3
Volt free remote start/stop
3
24 VDC fire alarm shutdown
3
Volt Free Common Run & Trip Indication
3
7 Day Time Clock
3
Internal or external locations
3
Sensor Control
Temperature
O
Humidity
O
Pressure
O
BlueSense - Energy Saving Package
3
Energy Efficient Speed Control
3
Air Quality Sensor (CO & VOC)
3
Post Installation Optimising
3
2
O = Option
For buildings with faulty and deteriorating ventilation plant, the obvious choice may appear to be replacement. However there are many reasons, not least economic ones, why the repair or refurbish alternatives should also be explored.
Features of Specialist Site Services
In addition to being a First Class ISO Certified Manufacturer, the VES Specialist Site Services Divison is the largest on-site solutions provider in the country.
f
Retail
f Restaurant Kitchen Ventilation
f Healthcare
f
Industrial & Process Applications
f Banking & f Swimming Pools f Government & f Education & Leisure Armed Forces Finance
or email
[email protected] Note: Data for design guidance only. For full details, outline drawings are available upon request.
100s of Ventilation Products f
Assistance in all Market Sectors
For all enquires about our services please contact us on +44 (0)8448 15 60 60
30
10% Online Discount f
Sales Freephone 0800 31 66 000
vesdirect.co.uk 31
Colour fan Twin Acoustic R
Product Specification Colourfan Twin Acoustic Fan Small Ventilation Units R
1.1. General A. Provide a twin fan unit to meet the performance and configuration as indicated in the schedule and detail drawings. The twin fan unit shall be tested in accordance with BS EN ISO 5801:2008, BS 848-1:2007 and shall be of the Colourfan type as manufactured by VES Andover Ltd a company accredited with BS EN ISO 9001:2008. 1.2 Unit Construction A. The unit shall be provided pre-assembled comprising of a rigidly constructed case, twin centrifugal backward curved fans with direct drive motors and rectangular spigots. B. The unit shall be supplied with an integrated pre-wired, factory fitted and tested controls package or pre-wired to an external isolator. C. The unit shall be available in plantroom or weatherproof construction as indicated in the schedule and detail drawings. D. Sizes 0-10 shall have rectangular duct spigots complete with 30mm MEZ flange as indicated in the schedule and detail drawings. E. Weatherproof units shall be available with horizontal inlet spigot as indicated in the schedule and detail drawings. Plantroom units shall be available with horizontal spigot as standard. F. Weatherproof units shall be available with an outlet louvre or spigot as indicated in the schedule and detail drawings. G. The unit casework shall incorporate high quality rubber gaskets seals on service doors and panels. H. The unit shall be provided pre-assembled comprising of a rigidly constructed 50mm tubular aluminum case, double skinned galvanised sheet steel panels. I. Access for maintenance shall be via hinged panels, allowing access for the cleaning or removal of internal components as indicated in the schedule and detail drawings. J. Plantroom units shall be suitable for top or bottom access as indicated in the schedule and detail drawings. Weatherproof units shall be suitable for top access only via a removable weather lid. K. Plantroom only shall incorporate mounting brackets compatible with drop-rod support systems. L. 1. Sizes 0-3 Weatherproof units shall be supplied as standard with mounting feet. Plantroom units shall be available with optional mounting feet as indicated in the schedule. 2. Sizes 4-10 Weatherproof units shall be supplied as standard on a galvanised sheet steel channel base, the frame shall be 100mm high. M. Plantroom unit casework and spigots shall be supplied naturally finished in high quality galvanised steel as standard. Optional powdercoat colour as indicated in the schedule. N. Weatherproof units shall be supplied powdercoated signal grey RAL7004 as standard. Alternative colour according to schedule. O. The unit shall be designed to be secured to a suitable base, wall or ceiling, ensuring the use of correct fixings for the application and taking into account individual unit weight as indicated in the schedule and detail drawings. 1.3. Fans A. The fan impellers shall be of PA6 glass-fibre reinforced, backward curved plastic blade construction with galvanised steel mounting plate. B. The impellers shall be statically and dynamically balanced to G 2.5 / G 6.3 according to ISO1940 part 1. C. The fan impellers shall be mated with aerodynamic bell inlet eyes for high efficiency and low noise generation. D. The fan impellers are supplied as standard in natural uncoated finish. 1.4. Motors A. The fans shall incorporate external rotor motors to insulation class F, IP44 environmental protection rating and shall be supplied with thermal protection cut-out as standard. B. The integrated motor shall be supplied epoxy painted grey to RAL7032.
32
Colour fan Twin Acoustic
Product Code Guide
R
R
Product R
Fan Type Fan Size Phase
Colourfan Twin Acoustic
Unit Size Unit Config
/EE
Infill Handing
Case Construction
Main Heating [null] Control Panel Section
Options Colour Name Part No.
Ancillaries Examples
Inlet/Outlet
R
33
[null]
Intelligent controls enhance performance whilst saving energy and money.
Main Filter
Heat Recovery
CAT
Temperature
Energy Saving
CPF0-1/P/C CATVA0000/1200/STD NRGEX9000
Humidity
Thyristor Heater
Control Panel Silencer Feet
Plug & Play
Air Quality
[null] /R7004
Filters
/SP /L
Speed Control
Case Construction
/ISC /CPSC
Energy Efficient Fans
Demand Ventilation
/PH /WH
Prewired/Fitted Controls
Colour
Manufactured in the UK
Download specification from www.ves.co.uk/information-centre
Please note: Weatherproof units are supplied in R7004 powdercoating as standard
4
Excellent build quality ensures minimal noise breakout, low SFPs and air tight performance.
[null]=Galvanised /R=RAL (colours)
1
/RT /RB /LT /LB
Inlet / Outlet /SP=Square Spigot /L=Louvre
F. Dampers shall be of opposed blade type, incorporating gasket seals between blades and sealed angles on the frame to ensure maximum sealing efficiency when the blades are closed.
Robust Construction
-1 -1 -1 -1 -1 -1 -1 -3
E. Dampers shall incorporate an aluminium extruded channel frame and aluminium damper blades, mounted on nylon cogs with nylon bearing inserts. Blade operation shall be via a 12mm sq. spindle mounted to one side of the damper.
G. Dampers shall be suitable for use with optional 230 VAC or 24 VAC open/close actuator as supplied by VES Andover Ltd.
VES employs a range of experts in disciplines including: air movement, noise control, air conditioning, controls, electrics and product refurbishment, and we have key staff who have worked at VES for many years.
-3
C. The silencer casework shall be provided naturally finished in high quality galvanised steel as standard. Internal and external powder coat available as indicated in the schedule. Colour to be in accordance with schedule. D. The plantroom unit shall be fully compatible with loose spigot mounted dampers suitable for direct fitting to the unit.
5
1 1 2 3 4 5 6 7
co mp lia nt
Main Filter [null]=No Filters
3
A. The unit shall be fully compatible with a standard range of spigot mounted silencers. The silencers shall be suitable for duct mounting or direct mounting to the unit as indicated in the schedule. B. The silencer shall be a rigidly constructed 50mm tubular aluminium case double skinned galvanised sheet steel panels incorporating internal splitters lined with resin bonded mineral wool. Polythene and perforated metal sheet lining shall be available where indicated in the schedule.
Control Panel Section /ISC=Isolator and Speed Control /CPSC=Control Panel and Speed Control
6
5 4 4 4 4 4 4 4
L. 7 day time.
1.7 Ancillaries
Versatile location, handing and access options meet the widest range of project requirements.
00 01 02 03 04 05 06 07
K. Start stop from remote volt free contacts.
N. Volt free enable, and 24 VDC fire alarm interface.
Versatile Options
-3
J. Duty share with 12 hour run-time memory retention.
M. Volt free run and trip indicators.
2
8
I. Fully programmable digital controller with commissioning and adjustment for constant pressure, humidity and temperate applications.
4
H. Automatic fan change over on airflow failure.
08
Infill /EE = 50mm
G. Fitted controls shall be fully pre-wired to internal components.
-3
F. Fitted controls shall be supplied with a wired AHU mounted LCD controller. Optional room user interfaces are available.
9
E. Control panels shall have individual circuit breakers where indicated in the schedule and detail drawings.
Handing /RT=Right Top /RB=Right Bottom /LT=Left Top /LB=Left Bottom
Simple connection and pre-installed features save on site costs and reduce lead times. Carefully designed maintenance features minimise downtime and total cost of ownership.
D. Controls shall be supplied with internally mounted circuit breakers, run, trip and panel live indication and lockable door isolation switch.
10
B. The unit shall be available with optional unit mounted CPF control panel as manufactured and factory fitted by VES Andover Ltd to suit, or alternative loose CPF panel for installation by others. If no control panel is ordered the unit will be supplied with local isolator for unit mains connections.
4
A. The unit shall be fitted as standard with EC fan speed control system to match fan type with max/min speed and 0-10 VDC BMS control, i.e. Air Quality or Temperature sensor.
4
1.6 Controls
09
A. The unit shall be designed to operate with process air temperatures from -20 OC to 40 OC, and humidity up to 80%.
Main Heating [null]=No Heating
Simple Installation and Maintenance
Experience and expertise
VES has over 12000m2 of manufacturing and stores space, and has state of the art sheet metalworking equipment, plus a large powder coating plant. VES also has a substantial controls department, and makes components such as dampers and electric heaters in-house. This not only provides employment for local people, but also many suppliers around the UK.
1.5 Operation Environment
C. Fitted Controls shall be positioned as indicated in the schedule and detail drawings.
VES operates a quality assurance system to ISO 9001, monitored by the BSI. The air movement products are tested in-house to BS EN ISO 5801:2008, BS 848-1:2007 and submitted for external testing and approval when necessary. VES specialise in bespoke designs for ventilation units. Whatever the issue, be it space, noise or temperature, VES can provide a design solution to meet the requirements of the project.
From the moment we receive your enquiry, to delivery and beyond; we have the people in place to give excellent customer service. The VES after sales service covers the whole of the UK and is among the best in the industry.
Energy saving packages combine intelligent controls technology, products and services.
R
High quality, flexible solutions
Superior customer service
Optimum Performance Our quietest twin air handling unit, meeting regulations and maximising performance.
10
The product range encompasses all types of ventilation products, including those required for commercial, industrial, public and domestic buildings. The emphasis is on low energy products and sophisticated controls to meet Building Regulation requirements. The range extends from a small bathroom extract fan up to large bespoke air handling units. There are specialist heat recovery units; high temperature fans for kitchen hood extract; duct, wall, ceiling and roof units; low noise products, silencers and fitted controls.
Features and Benefits
Product CAT=Colourfan Twin Acoustic
The Colourfan Twin Acoustic is suitable for many installations including schools, offices, libraries, hotels and retail establishments. Designed to fit any application, the units have been independently acoustically tested to BS EN ISO 3744:2010.
Colourfan Twin Acoustic
Unit Config /PH=Plantroom Horizontal Inlet/Outlet /WH=Weatherproof Horizontal Inlet/Outlet
Complete range of products
R
Colourfan is a range of small air handling ventilation units from VES, including Supply, Extract and Twin Extract, designed around a single product platform, with unique and innovative benefits across the range. Installation and maintenance is simplified through quick change “Plug & Play” connectors or pre-wired fitted controls.
Example Coding
VES has been supplying products for the HVAC industry for over 40 years, and have the in-depth knowledge and resources to provide solutions to all ventilation related requirements. We are a substantial British manufacturing company with over 250 employees, several factories plus a regional base in the north of England, and sales engineers located throughout the UK.
Colourfan Twin Acoustic
Twin CAT 0051-1/PH/EE/LT/CPSC/L
Why choose VES
Colour fan
R
Colourfan Twin Acoustic Step by Step Guide
1
Twin Acoustic
Other products and services from the complete range of VES HVAC solutions:
Choose Duties up to 2.8 m3/s
Air Handling Units • •
Colourfan Twin Acoustic
• • • •
R
Duties up to 2.8 m3/s
Supply and extract, combined or separate. Heat recovery including crossflow plate heat exchangers, thermal wheels and run-around coils. Plantroom or weatherproof, flat or stacked. Fitted silencers, inverters and controls. Matching DX condensing units. Various case constructions including EN 1886 certified units.
• • • •
a b
In-line centrifugal, with forward or backward curved impellers. Round, axial and mixed flow fans. Fitted silencers available on all units. Manual and automatic speed controllers available.
2
Performance Curve
Unit Configuration
c d
Specify your chosen unit
Controls
co m pl ia nt
requirements, including BB93
f Wide range of models for ceiling void,
For ceiling void, plantroom and weatherproof. Many models and configurations. Fitted auto-changeover system.
to achieve L2 Building Regulations
f BlueSense Intelligent Controls, with
All types for commercial, industrial and domestic premises.
Colourfan
•
• •
Heavy duty high temperature fans for hot greasy air. Motors out of airstream. Single inlet fans, in-line and vertical jet roof units.
Control Panels
3
• • • •
Add control packages for performance and efficiency Pages 28-30
Filters
Case Construction
Prewired/Fitted Controls
Thyristor Heater
Energy Efficient Fans
Speed Control
Humidity
Temperature
Heat Recovery
Specify bespoke options for Colourfan products Page 31 R
Colourfan
Off the shelf and built to order panels. Air quality sensors and energy savers. Intelligent control software. A range of remotes including touch screen.
• • •
Matching silencers available for all ventilation products. Silencers designed to meet noise criteria. Cleanable silencers. Weatherproof silencers.
Specialist Site Services • • • • • • • •
Plant refurbishment. Energy saving upgrades. Noise reduction. Site surveys. Kitchen ventilation. AHU flat pack installation. Maintenance. Spares.
R
Supply Acoustic and Supply Units
Noise Control •
Plug & Play
4
Demand Ventilation
R
Twin Units
duty share for continuous ventilation
Kitchen Hood Extract Fans
Noise Data and Silencer Option
Refer to pages 6-27.
Also available...
f High efficiency EC fans with Low SFPs
Three ranges for volume and pressure. Curb and soaker sheet bases.
The Colourfan Twin Acoustic high efficiency, low noise unit with duties up to 2.8 m3/s, low Specific Fan Power and low energy / high efficiency fans.
plantroom and external locations
Wall and Ceiling Fans •
Twin Acoustic DUTIES UP 3 to 2.8 m /s
to BS EN ISO 3744:2010
f Low noise to help meet acoustic
Roof Extract Units • •
R
f Independent Acoustic Testing
Twin Fans • • •
Colourfan
Duties up to 2.8 m3/s
Duct Fans
R
Buy from
Colourfan Twin Acoustic Unit
Member
C
Colourfan Twin Acoustic R
VES reserve the right to amend product specifications and details without notice.
VES Head Office Eagle Close, Chandlers Ford Industrial Estate, Chandlers Ford, Eastleigh, Hampshire SO53 4NF Tel: 08448 15 60 60 Fax: 023 8026 1204
R
Extract Acoustic and Extract Units
2013 VES
Issue CAT01W - 07/2013 www.vesdirect.co.uk
Colourfan
part of a complete range of innovative, flexible products from the HVAC experts
VES Manchester Office Unit 6, Willan Enterprise Centre, 4th Avenue, The Village, Trafford Park, Manchester M17 1DB Tel: 0161 848 8711 Fax: 0161 848 7268
For details on Colourfan product codes please turn to the back of this flap.
VES Glasgow Office Unit 15, Evans Business Centre, Springhill Parkway, Glasgow Business Park, Glasgow G69 6GA Tel: 0141 771 6823 Fax: 0141 771 6892
ves.co.uk
vesdirect.co.uk
[email protected]
R
R