COMBINATION INSTALLATIONS Classic Wall Oven/ Warming Drawer Revised 08/25/08 1/1 PLANNING GUIDE All tolerances: +1/16”, -0, (+1.6mm, -0) unless otherwise stated "C" 1 1/8“ (29mm) Min. Alternate Electrical Location Recommended Electrical Location "A" "B" 1 1 1/2” (38mm) Min. "E" "D" Electrical Location 1 3/4” (19mm) Min. 10 7/8” (276mm) Recommended 4“ Typical Toe Kick Single wall oven, warming oven stacked cutout dimensions Wall Oven Models “A” Cutout Height “B” Cutout Width “C” Min. Cabinet Width Warming Oven Models 25 1/2” (648mm) 27” (686mm) 24” Single 30” 27 1/2” (699mm) 28 1/2” (724mm) 30”” (762mm) 27” Single 36” 27 1/8” (689mm) 34 1/2” (876mm) 36” (914mm) 30” Double 27” 49 1/16” (1246mm) 25 1/2” (724mm) 27” (686mm) 36” 28 1/2” (724mm) 30” (762mm) Single 27” Double 30” “D” Cutout Height “E” Cutout Width 22 1/2” (572mm) 9 1/8” (232mm) 25 1/2” (648mm) 28 1/2” (724mm) 34 3/8” (873mm) NOTE: 1. 3/4” (19mm) support platform (flush with cutout). 2. See individual appliance Planning Guide pages to determine overlays. 3. Spacing between appliances and drawers/doors shown is minimum required to allow for ventilation and prevent scraping. Additional space may need to be added for appearance. Web: http://www.Dacor.com Corporate Phone: 800-793-0093 Specifications are subject to change without notice. See installation instructions for additional details. CI.16