Preview only show first 10 pages with watermark. For full document please download

Combination Configuration Dct_ervxx15

   EMBED


Share

Transcript

COMBINATION INSTALLATIONS Revised 10/28/11 Page 1/1 Document # PGCI-023 DCT Series Drop-In Gas Cooktop with ERVxx15 Raised Vent Cutout Dimensions PLANNING GUIDE warning Cutout tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated • Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. • All appliances must be installed in accordance with the accompanying installation instructions. Rear wall Vertical combustible surface 4 1/4” (10.8 cm) min. from mounting surface to combustibles below cooktop chassis C F Raised Vent Compatibility If installing the cooktop with a raised vent, install only the Dacor raised vent model specified in the table below. Installation of any other raised vent model may cause improper operation. E D F Minimum distance to combustible side wall above countertop (both sides) 1 5/8” min. (4.1 cm) Installation Type (C) Minimum DCT305 with ERV3015 raised vent DCT365 with ERV3615 raised vent 3/8” (1.0 cm) (D) (E) 22 3/4" (57.8 cm) 3/8” min. (1.0 cm) flat countertop overhang required behind cutout Stiffener (F) Minimum 27 5/8” (70.2 cm) 6 7/8" (17.5 cm) 33 5/8" (85.4 cm) Countertop DCT Series cooktop Cabinet face 3/8” min. (1.0 cm) space behind raised vent chassis to clear stiffener ERVxx15 raised vent. Check raised vent dimensions/specifications to determine proper fit Floor Side View - DCT series Cooktop with approved Raised Vent All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093