Preview only show first 10 pages with watermark. For full document please download

Commercial Emergency Vf6 Series Cm

   EMBED


Share

Transcript

CM-21050 codes and standards lamps • • • • • VF6 Unit contains two 5W MR11 lamps. The unit has fixed lens covering the two MR11 lamps. The lamps are adjustable. ETL listed to UL Standard 924 NFPA 101 (Life Safety Code) NFPA 70 (National Electric Code) Low Profile meets ADA specifications on lighting fixtures. construction • Flame rated, UV stable ABS thermoplastic front housing cover and back plate. • Lens is constructed of polycarbonate thermoplastic. • Unit is only available in white finish. installation Commercial Emergency battery • 6V maintenance free lead acid battery. • Battery has an expected service life of 5 to 7 years and an operating temperature range of 65°F (19°C) to 85°F (30°C). • Provides a minimum of 90 minutes emergency illumination. VF6 Series Value+II Fixed Lens Thermoplastic Emergency Unit warranty • Full 5 year warranty on units. (lamps not included) • Snap together quick mount design. • Wall or ceiling mounts. • Unit mounts up to a standard 4" square or octagon outlet box. electronics • Built in circuitry protection, low voltage battery disconnect and transformer isolation. • Solid state charger, test switch and LED AC charge indicator light. • 120/277VAC selectable input. • Power Consumption: 6.12 Watts (.051 mA) @ 120V, 6.37 Watts (.023 mA) @ 277V. Specifier’s Reference Project Type Model No. Comments Green Product Choice:VF6 Catalog Number VF6 Volts 6 Total Wattage Housing Color 12 White Accessories (Order Separately) WG3 – Wire Guard PCS1 – Polycarbonate Vandal Shield © 2013 Koninklijke Philips Electronics N.V.  All rights reserved. Specifications are subject to change without notice. CM_21050  03/13  Lamp Type 5W MR11 CM-21050 VF6 Series Value+II Fixed Lens Thermoplastic Emergency Unit dimensions 3" (76.2mm) 5-1/16" (128.3mm) 11-1/16" (280.9mm) performance Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes open space with no obstructions, mounting height: 8', ceiling height: 9', and reflectances: 80/50/20. Analysis based on independently tested photometrics. VF6 VF6 6' 3' 7' Avg fc = 1.00 Min fc = 0.9 Max fc = 1.00 Max/Min = 1.11 5' Avg fc = 1.04 Min fc = 0.6 Max fc = 1.3 Max/Min = 2.17 © 2013 Koninklijke Philips Electronics N.V.  All rights reserved. Specifications are subject to change without notice. Philips Lighting Company 200 Franklin Square Drive Somerset, NJ  08873 Phone: 855-486-2216 Philips Lighting Company 281 Hillmount Road Markham ON, Canada L6C 2S3 Phone: 800-668-9008 CM_21050  03/13  www.philips.com/luminaires www.philips.com/luminaires