Transcript
Communication PSS Ethernet PSS Ethernet, PSS1 Ethernet Technical details
PSS Ethernet
Function Application range Electrical data Power consumption Supply voltage “AUI PWR” Tolerance range “AUI PWR”
Ethernet module Non-safety-related applications
Power consumption “AUI PWR” Connection “AUI PWR” Configuration interface Ethernet Ethernet interfaces
Standard communications module for connecting to Ethernet.
Features ● supported application header - SINEC S5 application protocol - SINEC S7 application protocol - Modbus TCP ● supported protocols -TCP/IP - H1 - RFC 1006 ● Menu-driven configuration software for the most common PC operating systems ● Parameters are stored in nonvolatile memory in the module’s Flash Memory ● Ethernet connection via Twisted Pair (RJ45) or AUI (IEEE 802.3) ● A separate supply voltage is required when using the AUI interface ● Connection test and status displayed via LEDs
Transmission rate IP address Communication structure Mechanical data Space requirement Weight Environmental data Protection type (EN 60529, 10/91) Ambient temperature (DIN IEC 68-2-14, 06/87) Storage temperature (EN 60068-2-1/-2, 03/93) Climatic suitability Condensation Vibration (EN 60068-2-6, 04/95)
Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail:
[email protected]
PSS1 Ethernet
430 mA 430 mA 24 VDC 24 VDC 20 ... 30 VDC including residual ripple of max. ± 1.2 V 7W 7W Screw connector RS 232/RS 485 RS 232/RS 485 Twisted Pair (RJ45) AUI (IEEE 802.3) 10 MBit/s 10 MBit/s Can be set using the configuration software Via standard function blocks 1 slot 1032 g
1 slot 417 g
IP 20, installed on module rack 0 ... +60 °C 0 ... +60 °C -25 ... +70 °C
-25 ... +70 °C
IEC 68-2-30, IEC 68-2-14 Not permitted Not permitted Frequency range: 10 ... 100 Hz Amplitude: 0.1 mm, max 5g
PSS-D-2-243-11/01
Communication PSS Ethernet PSS Ethernet, PSS1 Ethernet Description The communications module PSS(1) Ethernet can be used to connect a programmable safety system from the PSS 3000 or PSS 3100 series to Ethernet. The following options are available: ● Connecting systems from the PSS 3000 or PSS 3100 series ● Connection to systems from other manufacturers (e.g. Siemens S5/ S7) ● Connection to graphics systems ● Connection to a host PC at control level Communication is possible via TCP/ IP, H1 or RFC 1006. If parameters are set for Ethernet connections, communication with the named protocols can run in parallel. The Ethernet connection is configured using a PC. Menu-driven configuration software is available for operating systems Windows 95, Windows 2000 and Windows NT. This is available as part of the software set “PSS SW Ethernet Set”. The configuration can be made online via one of the Ethernet interfaces. Parameters are stored in the module’s non-volatile Flash Memory. Special standard function blocks are required in the PSS as communication drivers for data exchange. These are available as part of the software set “PSS SW Ethernet Set”. On the CPU types listed below, the modules are only supported from the version numbers stated: • PSS CPU from Version 2.3 • PSS1 CPU from Version 1.7 • PSS SF CPU from Version 1.3 • PSS1 SF CPU from Version 1.3 • PSS SB CPU from Version 1.5 • PSS1 SB CPU from Version 1.5
Order reference System Description Order number
PSS 3000 PSS Ethernet 301 157
PSS SW Ethernet Set
301 273...1)
PSS 3100 PSS1 Ethernet 302 157
When ordering: Please state the type of licence you require after the order number (..B for basic licence, ..K for copy licence, ..G for general licence), e.g. 301 183B 1)
Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail:
[email protected]