Preview only show first 10 pages with watermark. For full document please download

Communication Cable

   EMBED


Share

Transcript

Technical Data Effective September 19, 2014 Communication Cable Catalog# Prepared by Project Date Comments Type Overview Cooper Controls communications cable are used to interconnect lighting control panels and peripheral devices. The cable provides one 18 AWG wire pair to deliver power to peripherals and one 22 AWG twisted and shielded wire pair to carry data transmissions. Both nonplenum (LCCNP) and plenum rated (LCCP) versions are available. Features Interconnects lighting control panels and peripheral devices Carries both power and data in a single cable 18 AWG 18 AWG 22 AWG 22 AWG } 24 AWG Drain Wire Technical Data  Communication Cable   September 2014 Specifications Ordering Outer Jacket Material: PVC Color: LCCP-Natural; LCCNP-Black Nominal diameter: LCCP-0.205 in.; LCCNP-0.250 in. Power Wire Pair Conductors: 2 x 18 AWG, tinned copper Colors: Red/Black Shield: None Conductors: 2 x 22 AWG, tinned copper Data Wire Pair Colors: Blue/White Shield: Aluminum foil (100% coverage) Shield drain wire: 24 AWG Impedance: 100 Ohms NEC/UL specification: LCCP-CMP; LCCNP-CMR Applicable Standards CEC/CUL specification: LCCP-CMP; LCCNP-CMG This is an accessory with the ControlKeeper and LiteKeeper Lighting Control Systems. When ordering, specify the communication cable type as a separate accessory. Model Description LCCP Eaton’s Cooper Controls communication cable; plenum rated Eaton’s Cooper Controls communication cable; non-plenum rated LCCNP Conductors Function Color Construction Normal Size Power Common Data Data Drain Red Black Blue White 16 strand x 30 AWG tinned copper 16 strand x 30 AWG tinned copper 7 strand x 30 AWG tinned copper 7 strand x 30 AWG tinned copper 7 strand x 32 AWG tinned copper 18 18 22 22 24 Twisted pair in foil shield AWG AWG AWG AWG AWG General Type LCCP LCCNP Cable Outer Jacket (PVC) Ratings Color Nominal Diameter Reel Length Impedance (Data Pair) Maximum Operating Voltage Temperature Plenum Rated? Natural Black 0.205 0.250 500 Feet 500 Feet 100 Ohm 100 Ohm 300V RMS 300V RMS 75° C 75° C Yes No Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton’s Cooper Controls Business 203 Cooper Circle Peachtree City, GA 30269 coopercontrol.com © 2014 Eaton All Rights Reserved Printed in USA Publication No. ACC131636 September 19, 2014 Eaton is a registered trademark. All other trademarks are property of their respective owners.