Preview only show first 10 pages with watermark. For full document please download

Comnet™ Cnfe6+2uspoe 8 Ethernet Ports

   EMBED


Share

Transcript

INSTALLATION AND OPERATION MANUAL CNFE6+2USPOE 10/100TX Drop/Insert/Repeat 6TX/2FX Ethernet Switch with PoE The ComNet CNFE6+2USPOE provides 8 Ethernet ports operating at 10/100 Mbs and is designed to combine six electrical ports into a second optical port that forwards this data to the next CNFE6+2USPOE. The optical ports are designed to forward the data from the six electrical ports to its up network. In addition, the electrical ports can supply up to thirty (30) watts of power (“Power Over Ethernet”), based on IEEE802.3at standard, to remote Ethernet devices. This product uses ST optical connections and can be supplied to operate over Singlemode or Multimode optical fiber. There is no programming required to use this product. It is “Plug-and-Play”. Port 8 can be used to monitor the data flow from the optical port to permit “local” observation and diagnostics of the equipment when the diagnostic switch is set to on. LED indicators confirm the operating status of this device. The ComNet CNFE6+2USPOE may be either wall mounted, rack mounted (“ComFit” packaging) or DIN-rail mounted with the use of the ComNet DINBKT1 adapter. See Figures A on Page 5 for mounting instructions. See Figures 1 – 7 for complete installation details. INS_CNFE6+2USPOE_REV– 07/08/11 PAGE 1 INSTALLATION AND OPERATION MANUAL CNFE6+2USPOE FIGURE 1 – TYPICAL APPLICATION CNFE6+2USPOE Monitor PC Fiber 1 Insert Tech Support: 1.888.678.9427 48VDC in ... ... ... ... 1 Ethernet ... 5 Fiber 10/100TX 1 2 3 4 5 6 7 8 PoE PC 1 Ethernet 48VDC in 10/100TX ... ... ... PoE 2 3 4 5 6 7 8 CNFE6+2USPOE Fiber ... 6 Insert INS_CNFE6+2USPOE_REV– 07/08/11 PAGE 2 INSTALLATION AND OPERATION MANUAL CNFE6+2USPOE FIGURE 2 – CNFE6+2USPOE OPTICAL FIBER RJ-45 RJ-45 RJ-45 BLACK BLACK WITH WHITE STRIPE RJ-45 For Power over Ethernet, use 48 VDC @ 5 Amps PS. (ComNet Model PS48VDC-5ADIN sold separately) FIGURE 3 – CNFE6+2USPOE FRONT PANEL FIGURE 4 – REAR SWITCH SETTINGS REAR PANEL EFFECT PORT VLAN DIAGNOSTIC VLAN & Diagnostic Enabled ON ON VLAN Enabled, Diagnostic Disabled ON OFF VLAN & Diagnostic Disabled OFF ON VLAN & Diagnostic Disabled OFF OFF NOTE: Diagnostic only functions when VLAN is enabled. When VLAN and Diagnostic are enabled, Port 8 can be connected to all other ports from 1 – 7. NOTE: Remove Electrical Connector for Rack Mount Units Tech Support: 1.888.678.9427 INS_CNFE6+2USPOE_REV– 07/08/11 PAGE 3 INSTALLATION AND OPERATION MANUAL CNFE6+2USPOE FIGURE 5 – LED INDICATORS LINK (PORT 1 & 2) LINK (PORT 3 – 8) POE (PORT 3 – 8) POWER SOLID Link Up Link Up Power Suppled to PD Power Applied BLINKING Data Activity Data Activity POE Negotiating – OFF No Data Link No Data Link No Power Supplied Power Not Applied FIGURE 6 – APPLICATION DIAGRAM WITHOUT MULTICAST TRAFFIC IGMP Disabled, VLAN disabled on the units. CNGE2FE24MODMS P1 CNFE6+2USPOE P1 CNFE6+2USPOE P2 P1 CNFE6+2USPOE PC Connections on Ports 3–8 Tech Support: 1.888.678.9427 INS_CNFE6+2USPOE_REV– 07/08/11 PAGE 4 INSTALLATION AND OPERATION MANUAL CNFE6+2USPOE FIGURE 7 – APPLICATION DIAGRAM WITH MULTICAST TRAFFIC IGMP Enabled, VLAN enabled on the units CNGE2FE24MODMS P1 P1 CNFE6+2USPOE P2 P1 Camera Connections Providing PoE on Ports 3–8 Tech Support: 1.888.678.9427 INS_CNFE6+2USPOE_REV– 07/08/11 PAGE 5 MECHANICAL INSTALLATION INSTRUCTIONS Installation Considerations This fiber-optic link is supplied as a Standalone/Rack module. Units should be installed in dry locations protected from extremes of temperature and humidity. C1-US, C1-EU, C1-AU or C1-CH Card Cage Racks Figure A Dimensions are for a standard ComNet™ two slot module .156 [3.96 mm] CAUTION: Although the units are hot-swappable and may be installed without turning power off to the rack, ComNet recommends that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove electrical connector before installing in card cage rack. 1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack’s connector panel. Seating may require thumb pressure on the top and bottom of the card’s front panel. CAUTION: Take care not to press on any of the LEDs. .313 [7.95 mm] 2. Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack. WARNING: Unit is to be used with a Listed Class 2 or LPS power supply rated 48 VDC @ 5 Amps (PS48VDC-5ADIN sold separately). IMPORTANT SAFEGUARDS: A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer. B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. 3 Corporate Drive | Danbury, CT 06810 | USA T: 203.796.5300 | F: 203.796.5303 | Tech Support: 1.888.678.9427 | [email protected] 8 Turnberry Park Road | Gildersome | Morley | Leeds, UK LS27 7LE T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | [email protected]_CNFE6+2USPOE_REV– © 2012 Communications Networks Corporation. All Rights Reserved. “ComNet” and the “ComNet Logo” are registered trademarks of Communication Networks, LLC. 07/08/11 PAGE 6