Preview only show first 10 pages with watermark. For full document please download

Compact Fielbus Stations In Ip67

   EMBED


Share

Transcript

COMPACT FIELDBUS STATIONS IN IP67 F774/01 Fieldbus Components for the Harsh Industrial Environment The compact fieldbus stations from TURCK are ideal for use under demanding electrical and mechanical conditions in harsh industrial environments and stand out due to their common properties, which is why they offer decisive advantages. No matter whether for PROFIBUS-DP, DeviceNet™ or Ethernet – all compact fieldbus stations are designed according to the same concept and feature the following characteristics: • Standardised connection technology with metal connectors • Address setting via coded rotary switches under transparent protective cover • Robust glass-fibre reinforced plastic housings with fully encapsulated module electronics • Shock and vibration resistant according to DIN/EN FXDP – configurable PROFIBUS-DP modules • Channel-specific diagnostics according to PROFIBUS-DP standard • Parameterisable I/O range • Up to 16 channels FLDP – PROFIBUS-DP modules • Common short-circuit diagnostics • Up to 32 channels REP-DP-0002 – PROFIBUS-DP repeater • Segmentation and expansion of PROFIBUS-DP networks • Automatic disconnection of faulty segments FENP– Ethernet modules • Common diagnostics • Website for display of status and I/O data with standard web browser • Up to 16 channels Ethernet switch • Segmentation of network traffic • 5 or 9 ports • 10/100 Mbps half/full duplex operation 2 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Phone 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com FSDP – PROFIsafe modules • Safetyrelated fieldbus stations • Up to 16 channels • SIL 2/SIL 3 according to IEC 61508 Cordsets – Premoulded cables for bus, power and I/Os 1 • One solution for all application conditions • From simple PVC through PUR up to highly flexible cables • Straight or angled connectors FDNP – DeviceNet™ modules • Individual or common diagnostics • Connection of actuator supply • Up to 16 channels Accessories REP-DN – CAN (DeviceNetTM) repeater • Segmentation and expansion of CAN or DeviceNetTM networks • • • • • T- and Y-pieces Terminating resistors Flange connectors Feed-through receptacles Passive junction boxes FDNL – DeviceNetTM modules • Individual or common diagnostics • Up to 16 channels • Power supply via DeviceNet™ Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Phone 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 3 /0704 Bitte senden Sie mir Unterlagen: Please send me more information: Sensortechnik ❑ Induktive Sensoren ❑ uprox® induktive Sensoren ❑ Induktive Sensoren für Schwenkantriebe ❑ Magnetfeldsensoren ❑ Opto-Sensoren ❑ Geräte für den Personenschutz ❑ Kapazitive Sensoren ❑ Ultraschallsensoren ❑ Strömungssensoren ❑ Drucksensoren ❑ Füllstandssensoren levelprox® ❑ Temperatursensoren ❑ Identifikationssysteme ❑ Linearwegsensoren ❑ Drehwegsensoren ❑ Steckverbinder ❑ CD-ROM Sensortechnik Sensors ❑ Inductive sensors ❑ uprox® inductive sensors ❑ Inductive sensors for rotary actuators ❑ Magnetic-field sensors ❑ Photoelectric sensors ❑ Machine safety equipment ❑ Capacitive sensors ❑ Ultrasonic sensors ❑ Flow sensors ❑ Pressure sensors ❑ Level sensors levelprox® ❑ Temperature sensors ❑ Identification systems ❑ Linear position sensors ❑ Rotary position sensors ❑ Connectors ❑ CD-ROM Sensors Interfacetechnik ❑ Interfacetechnik im Aufbaugehäuse für Hutschiene (DIN 50022), Platten- oder Bodenmontage ❑ Interfacetechnik auf 19"-Karte für Baugruppenträger (DIN 41494) ❑ CD-ROM Interfacetechnik ❑ Miniaturrelais, Industrierelais, Zeitwürfel, Sockel ❑ Zeit- und Überwachungsrelais ❑ Ex-Schutz – Grundlagen für die Praxis (Übersichtsposter) Interface technology ❑ Devices in modular housings for top-hat rail (DIN 50022) or panel mounting ❑ Devices on 19" card for DIN-rail mounting (DIN 41494) ❑ CD-ROM Interface technology ❑ Miniature relays, industrial relays, time cubes, sockets ❑ Programmable relays and timers ❑ Explosion protection – basics for practical application (overview poster) Feldbustechnik ❑ Kompakte Feldbuskomponenten PROFIBUS-DP/DeviceNet™/ Ethernet ❑ piconet® – modulares FeldbusI/O-System in IP67 ❑ BL67 – modulares FeldbusI/O-System in IP67 ❑ BL20 – modulares FeldbusI/O-System in IP20 ❑ Remote-I/O-System excom® ❑ Segmentkoppler ❑ FOUNDATION™ fieldbus Feldbuskomponenten ❑ PROFIBUS-PA Feldbuskomponenten ❑ Multibarriere ❑ Feldbussystem sensoplex® 2 /2 Ex Fieldbus technology ❑ Compact fieldbus components PROFIBUS-DP/DeviceNet™/ Ethernet ❑ piconet® – modular fieldbus I/Osystem in IP67 ❑ BL67 – modular fieldbus I/O-system in IP67 ❑ BL20 – modular fieldbus I/O-system in IP20 ❑ Remote I/O system excom® ❑ Segment coupler ❑ FOUNDATION™ fieldbus fieldbus components ❑ PROFIBUS-PA fieldbus components ❑ Multibarrier ❑ Fieldbus system sensoplex® 2 /2 Ex FAX-ANTWORT/FAX REPLY Absender/Sender: Name: Firma/Company: Abt./Position: Adresse/Address: Tel./Phone: E-Mail: Hans Turck GmbH & Co. KG Witzlebenstraße 7 45472 Mülheim an der Ruhr Germany Phone (+49) (2 08) 49 52-0 Fax (+49) (2 08) 49 52-264 E-Mail [email protected] Internet www.turck.com Fax: D300774 0704 4 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Phone 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Compact fieldbus stations in IP67 Basics of fieldbus systems System description – PROFIBUS-DP System description – DeviceNet™ System description – Ethernet 6 8 10 1 Compact fieldbus stations PROFIBUS-DP Device overview – compact fieldbus stations PROFIBUS-DP Type code – compact fieldbus stations PROFIBUS-DP FXDP stations, high feature – general functions FXDP stations, high feature – data sheets FLDP stations, economy version – general information FLDP stations, economy version – data sheets FSDP stations, PROFIsafe – general functions FSDP stations, PROFIsafe – data sheets 12 13 14 15 24 25 40 41 2 Compact fieldbus stations DeviceNet™ Device overview – compact fieldbus stations DeviceNet™ Type code – compact fieldbus stations DeviceNet™ FDNL/FDNP stations – general information FDNL/FDNP stations – data sheets 44 45 46 47 3 Compact fieldbus stations Ethernet Device overview – compact fieldbus stations Ethernet Type code – compact fieldbus stations Ethernet FENP stations – general information FENP stations – data sheets 66 67 68 69 4 Special modules PROFIBUS-DP – repeater DeviceNet™ – repeater DeviceNet™ – spanner module Ethernet – switches 74 76 78 80 5 Bus cables PROFIBUS-DP – bus cables CAN – bus cables Ethernet – bus cables A1 – 4 A1 – 8 A1 – 16 A1 Power cables Power cables, cable type 52 (5 x 1.5 mm2) Power cables, cable type 43 (4 x 1.5 mm2) Power cables, cable type IPS (4 x 0.34 mm2) A2 – 2 A2 – 4 A2 – 6 A2 Accessories – Bus PROFIBUS-DP – tees and Y pieces, terminating resistors – field wireable, flange and feed-through connectors CAN – tees and Y pieces, terminating resistors, passive junctions – field wireable, flange and feed-through connectors Ethernet – M12/RJ45 adapter A3 A3 A3 A3 A3 – 2 – 4 – 8 – 12 – 15 A3 Accessories – Power supply Cable type 52 – tees, field-wireable, flange and feed-through connectors Cable type 43 – tees, field-wireable, flange and feed-through connectors A4 – 3 A4 – 7 A4 Accessories - connectors for sensors and actuators Ø 8 mm, M8, M12 connectors and field-wireable versions DeviceNet™ – sealing plugs 7/8" and M12 x 1 A5 – 2 A5 – 21 A5 Type index Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Phone 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 84 5 /0704 System Description PROFIBUS-DP System description Within the PROFIBUS protocol family, PROFIBUS-DP is the speed-optimised protocol for communication between automation devices and the field periphery. PROFIBUS-DP is designed to replace cost-intensive, parallel signal transmission via digital and analogue sensors and actuators. PROFIBUS-DP is based on DIN 19245, part 1 and part 4. During the course of European fieldbus standardisation, PROFIBUS-DP has been integrated into the European field bus standard EN 50170. Several masters may be connected within a single network; in this case they pass on their transmission permission (Token Passing). PROFIBUS-DP uses a bit transmission layer (Physical Layer) based on the industrially proven RS485 standard. The system uses a shielded twisted 2-wire cable that is extremely resistant to electrical interference. PROFIBUS-DP is a master/slave system. During operation, the master constantly scans the connected slave stations. PROFIBUS-DP is suited for connection of a large number of I/O points. Up to 126 addressable bus nodes enable connection of thousands of analogue and digital I/O points within a network. Every PROFIBUS-DP module has a socalled "GSD“ file (Gerätestammdatendatei = device data base file) containing detailed information on the module: I/O data volume, transmission rates, revision status etc. The GSD file is needed to configure a station within a PROFIBUS-DP system. The GSD files can be downloaded from TURCK's internet site (www.turck.com). Maximum system expansion It is not permitted to use more than 32 devices per segment. One segment is defined as the bus section between two repeaters. If no repeaters are used, the entire network corresponds to one segment. The master and the repeaters also count among the connectable devices. Segments must comply with the specified maximum length and the respective transmission rates. Up to nine repeaters may be connected within a network. The maximum length of a bus line within a segment and the maximum number of repeaters are listed in the following table. . Transmission speed 9,6 19,2 93,75 187,5 500 1,5 12 KBd KBd KBd KBd KBd MBd MBd Length of the bus line Max. no. of repeaters 1200 m 1200 m 1200 m 1000 m 400 m 200 m 100 m 2 2 2 2 4 6 9 Max. no. of bus stations 126 126 126 126 126 126 126 PROFIBUS-DP – configuration software The screenshot shows an excerpt of the PROFIBUS-DP configuration software. 6 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Phone 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Application example The illustration outlines a model PROFIBUS-DP network assembled with TURCK devices. Alongside the compact IP67 fieldbus stations described in the catalogue, TURCK offers additional modular bus components for the IP20 (BL20) and the IP67 environment (BL67 and piconet®) which excel in flexibility and user-friendly set-up and configuration. SPS and PROFIBUS-DP interface card Premoulded cables in various designs, as well as field-wireable connectors, feedthrough receptacles for cabinet mounting, flange connectors, tees, terminating resistors and repeaters are available for network construction. Power supply BL20 PROFIBUSconnector IP20 D9T451-xM RKSW451-xM RKM52-xM FKW-FSW45-M12 RSF-RKF57/22 RKM52-x-RSM52 RSM-2RKM50 BS4151-0/9 WKM52-xM RKM52-x-RSM52 WKM52-x-WSM52 Ui U0 WKM52-x-WSM52 Ui U Uo 0 1 4 0 5 1 4 0 5 1 I9 I1 6 3 7 FXDP-... 4 FSDP-IM16-0001 I10 I2 I5 I1 I11 I3 DP-Address 2 Emergency stop switch I8 I4 I0 FLDP-IM16-0001 FXDP-XSG16-0001 Power U Power I0 Power 2 6 3 7 FLDP-... 5 F-Address x1000 x100 I12 I4 I6 I2 2 I5 x10 x1 x10 I13 x1 6 FSDP-... SIL3 Mode BMWS8251-8,5 I14 I6 I7 I3 Bus x100 1 0 SF SF 2 3 8 7 1 0 9 2 3 8 7 1 0 9 4 5 6 2 3 8 7 4 5 6 1 0 9 x10 2 3 8 7 6 5 4 4 5 6 8 7 x1 Out In Out In In 9 0 1 6 5 4 2 8 3 7 9 0 1 6 5 4 2 3 6 5 4 7 SIL SIL 2 3 Bus Slave Address (0-99) x1 4 5 6 I15 I7 SIL SIL 2 3 Bus x10 1 0 9 3 7 8 3 2 7 8 3 2 9 0 1 6 5 4 9 0 1 6 5 4 7 8 3 2 7 8 3 2 9 0 1 9 0 1 Out RSSW451-xM WSSW-WKSW451-xM BL67 D BL67 D BL67 D 0 0 1 1 BL67 D BL67 D 0 D 1 2 3 3 3 4 4 5 5 6 6 7 0 0 1 1 0 Sensor 0 0 Power 2 3 4 WAK3-x-SSP3/S90 3 4 6 7 BL67-B-8M8 5 BL67-B-4M12-P 6 1 2 BL67-B-4M8 3 BL67-B-1RSM 2 3 1 BL67-B-2M12 2 5 RSM-2RKM50 BL67 0 1 2 7 WSSW-WKSW451-xM BL67 0 1 2 2 7 WKM52-x-RSM52 WSSW-WKSW451-xM SDPL-... WSSW-RKSW451-xM WSSW-WKSW451-xM SDPB-... RSS4.5-PDP-TR SDPB-... Function SNNE-... Segment 2 Function REP-DP SNNE-... SNNE-... RKSWS4.5[5]RSSWS Segment 2 Segment 1 Segment 1 REP-DP-0002 Power RSS4.5-PDP-TR Power IPSKP4-x/S90 WSSW-RKSW451-xM piconet® IP-Link BS4151-0/9 RSM-2RKM50 WKM52-x-RSM52 further bus devices or active terminating resistor PDP-TRA BS4151-0/9 RKM52-x-RSM52 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Phone 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 7 /0704 1 System Description DeviceNet™ System description DeviceNet™ is an inexpensive transmission system for networking industrial field devices such as limit switches, photoelectric sensors, valve terminals, motor contactors, barcode scanners, frequency converters etc. Due to direct interconnection of devices, wiring expenses can be reduced significantly and detailed diagnostics, which are infeasbile with conventional wiring methods, are thus provided. the highest priority. The DeviceNet™ protocol defines theses higher priority messages by giving the input/output data messages the highest priority whereas configuration message have lower priority. DeviceNet™ is based on a so-called broadcast-oriented communication architecture, the CAN (Controller Area Network). CAN uses the CSMA/CA-bus access method. CSMA/CA ensures reliable transmission of the message with The bus chips and the input channels of the nodes are powered via the 24-VDC power supply. Some TURCK stations require an additional 24 VDC auxiliary power supply to operate possibly needed outputs. A DeviceNet™ network supports up to 64 nodes and an almost unlimited number of I/Os. The bus uses a line topology with short drop lines. Data and power are transferred via a single cable. The communication profile of the stations comprises: UCMM, Offline Connection Set, Polled I/O, COS/Cyclic, Bitstrobe, Device Heartbeat Message, Device Shut Down Message. The user may select a master/ slave, a multi-master or a combined system configuration according to his application needs. Maximum system expansion DeviceNet™ is based on a line structure with drop cables. The line is the main bus cable (trunk line) and requires a 120 Ω terminating resistor on both ends. The length of the trunk line depends on the Transmission speed 125 kBit/s 250 kBit/s 500 kBit/s transmission speed and the cable type used. Drop lines are branches off the bus and can be up to 6 m long. Trunk line (max.) 500 m (1640 ft) 250 m (820 ft) 100 m (328 ft) Drop line (per drop) 6 m (20 ft) 6 m (20 ft) 6 m (20 ft) The total (cumulated) length of the drops also depends on the transmission speed. The following table shows the maximum lengths of a DeviceNet™ line. Drop lines (total) 156 m (512 ft) 78 m (256 ft) 39 m (128 ft) Max. no. of nodes 64 64 64 DeviceNet™ configuration software The screenshot shows an excerpt of the DeviceNet™ configuration software. 8 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Phone 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Application example The illustration outlines a model DeviceNet™ network assembled with TURCK devices. Alongside the compact IP67 fieldbus stations described in the catalogue, TURCK offers additional modular bus components for the IP20 (BL20) and the IP67 environment (BL67 and piconet®) which excel in flexibility and user-friendly set-up and configuration. DeviceNet scanner Premoulded cables in various designs, as well as field-wireable connectors, feedthrough receptacles for cabinet mounting, flange connectors, tees, terminating resistors and repeaters are available for network construction. BL20 Power supply SPTC2 RSM-CBC5-5711-xM BUS OUT RSM5711-xM BUS IN SUPPLY RKM5711-xM RKM43-xM RSF-RKF40/22 RSF-RKF57/22 RSM-2RKM40 RKM43-x-RSM43 BS4148-0/9 RKM43-x-RSM43 WKM43-x-WSM43 WKM43-xM FDNP-CPG88-TT RSM-RKM5711-xM FDNP-XSG16-TT AUX AUX MOD MOD NET NET FDNL-CSG88-T FDNL-S0800-T MOD MOD NET Node Address (00-63, PGM) Data Rate (Kb) 500 AUTO 2 3 2 3 4 1 250 1 4 0 5 0 125 5 6 9 6 PGM 8 7 PGM MSD LSD NET Node Address (00-63, PGM) 2 3 2 3 1 4 4 1 0 5 0 5 6 6 9 8 7 PGM MSD LSD Node Address (00-63, PGM) 2 3 2 3 1 4 4 1 0 5 0 5 6 6 9 8 7 PGM MSD LSD Node Address (00-63, PGM) 2 3 2 3 1 4 4 1 0 5 0 5 6 6 9 8 7 PGM MSD LSD BS4151-0/9 RSM57-TR2 WKM5711-xM WSM-WKM5711-xM WSM-WKM5711-xM WSM-WKM5711-xM RSM-2RKM57 D BL67 D BL67 0 1 1 2 2 2 3 3 3 4 4 5 5 6 6 7 7 0 1 1 2 2 3 3 0 BL67 Sensor 0 1 1 2 2 3 WAK3-x-SSP3/S90 3 4 BL67-B-4M12-P 6 D 0 1 4 WSM-RKC572-xM BL67 0 1 0 5 D 0 BL67-B-4M8 WSM-WKM5711-xM BL67 BL67-B-2M12 RSM-WKM5711-xM D 7 5 6 BL67-B-8M8 BL67 7 WSC-RKC572-xM WSC-WKC572-xM SDNL-... SDNB -... SDNB -... REP-DN SNNE-... SNNE-... SNNE-10S-0001 RSE57-TR2 FSM-2FKM-57 Node Address (00-63, PGM) Data Rate (Kb) 500 AUTO 2 3 2 3 1 4 250 4 1 0 5 0 125 5 6 6 9 PGM 8 7 PGM MSD LSD RSM57-TR2 P1 IPSKP4-x/S90 JTBS-57-M634 J0 JTBS57-E434 piconet® IP-Link J1 RKM43-x-RSM43 J2 J3 J4 further DeviceNet nodes BS4148-0/9 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Phone 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 9 /0704 1 System Description Ethernet System description The most popular standard for networking office computers and associated components is Ethernet according to IEEE 802.3. At the control level of industrial networks, data transmission is almost entirely based on Ethernet networking technology. This standard permits interconnection of devices from different manufacturers via one and the same interface: the identical transmission physics and access mechanisms are userfriendly and significantly reduce network installation times and costs. E-mail and web servers etc. also use this technology with all its well established advantages. Data can be transferred world-wide via the internet from one Ethernet device to the other. Advanced automation solutions for the control level, at which large data packets have to be transmitted, mostly apply Ethernet as networking technology. Below this level, at the field level, where signals have to be handled, PROFIBUS-DP, DeviceNet™ or AS-Interface® are primarily used. The disadvantages are obvious: the transmission physics and the installation techniques differ, so that the networking technologies have to be made compatible with each other. In order to obtain consistency within the automation pyramid, Ethernet is suited to be used as a fieldbus right down to the sensor/actuator level. to the signal level. Due to the uniform mode of data transmission between the control and the field level, gateways, which are used to make different networks compatible with each other, are no longer needed and full network transparency is achieved. The Ethernet I/O station can thus be easily connected to local networks. Regardless of the network’s location, remote maintenance and process control can be carried out via the internet. Information on the station, such as status and I/O data can be accessed via a standard web server using the HTTP protocol. The availability of industrial hubs and switches and the development of suitable application protocols enable consistent use of the Ethernet TCP/IP standard down Topology The network topology for interconnection of Ethernet devices is a star or the starrelated tree structure. The maximum distance between two devices when using rigid cables for connection may not exceed 100 m. If flexible cables are used, the maximum length depends on the network construction. With a flexible 10 m cable the user is definitely ”on the safe side”. Switches and hubs interconnect the Ethernet devices and are thus the nodal points within the star structure. Hubs always send data to and receive data from all nodes, whereas switches feature a structurised data transmission mode. The switches organise data transfer within a routing table in which all connected devices are listed. This ensures that Ethernet data packets are generally only sent to the allocated target address. The Ethernet is thus not overloaded and collisions are avoided. Status polling via web server The status of TURCK’s FENP stations can be polled via an integrated web server. The web page to the right shows the station status, possible error indications and address settings. 10 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Phone 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Application example The illustration outlines a model Ethernet network assembled with TURCK devices. Alongside the compact IP67 fieldbus stations described in the catalogue, TURCK offers additional modular bus components for the IP20 (BL20) and the IP67 environment (BL67 and piconet®), which excel in flexibility and user-friendly set-up and configuration. Premoulded cables in various designs, as well as field-wireable connectors, feedthrough receptacles for cabinet mounting, flange connectors, tees, terminating resistors and repeaters are available for network construction. Power supply BL20 SPS with Ethernet interface RJ45S-RJ45S-843-xM RKM52-xM RSF-RKF57/22 BIC-84-E424 RSM-2RKM50 RKM52-x-RSM52 RKM52-x-RSM52 BS4151-0/9 RKM52-x-RSM52 SE-84X-E924 Power SE-84X-E924 LED OFF ON 10/100 10 Mbits 100 Mbits ------ Act/Link No Link Linked -Activity Power Port Blink 4 5 3 2 1 10-30 VDC Uplink Port 10/100 Act/Link 10/100 Act/Link 10/100 Act/Link 10/100 Act/Link 10/100 Act/Link 1 = N/C 2 = (- Voltage) 3 = N/C 4 = (+ Voltage) 5 = N/C I8 I0 I/O0 I/O8 AUX AUX I1 I9 I/O1 I/O9 I2 I10 I/O2 I/O10 I3 I11 I/O3 I/O11 10/100 Act/Link 10/100 Act/Link 10/100 Act/Link I4 I12 I5 I13 I6 I7 FENP-... FENP-XSG16 10/100 Act/Link FENP-S1600 9-Port Industrial Ethernet Switch I/O4 I/O13 I14 I/O6 I/O14 I15 I/O7 2 3 8 7 4 5 6 1 0 9 2 3 8 7 4 5 6 FENP-... I/O15 ACT/LNK 1 0 9 I/O12 I/O5 ACT/LNK 1 0 9 2 3 8 7 4 5 6 1 0 9 2 3 8 7 4 5 6 1 0 9 2 3 8 7 4 5 6 1 0 9 2 3 8 7 4 5 6 RSS-RSS-843-xM RSS-RSS-841-xM BL67 D BL67 D BL67 D BL67 D BL67 D D 0 0 0 0 1 1 1 1 1 2 2 3 3 2 2 3 4 4 5 5 6 RSM-2RKM50 BL67 6 7 7 0 SE-84X-E524 BL67 0 0 0 Sensor 0 WAK3-x-SSP3/S90 0 3 3 1 Power 1 2 2 3 BL67-B-4M8 2 BL67-B-2M12 1 2 BL67-B-1RSM 1 3 Power 4 OFF ON 10 Mbits 100 Mbits ------ No Link Linked Activity -- Blink Power Port 4 5 3 2 1 10-30 VDC 10/100 Act/Link Uplink Port 10/100 Act/Link 10/100 Act/Link 10/100 Act/Link 1 = N/C 2 = (- Voltage) 3 = N/C 4 = (+ Voltage) 5 = N/C 5 6 10/100 Act/Link 4 5 6 7 BL67-B-8M8 LED 10/100 Act/Link BL67-B-4M12-P SE-84X-E524 5-Port Industrial Ethernet Switch 7 WKM52-x-RSM52 SENL-... SNNE-... SNNE-... SNNE-... piconet® IP-Link SENB-... BS4151-0/9 RSM-2RKM50 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Phone 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 11 /0704 1 PROFIBUS-DP Compact fieldbus stations - device overview Housing version 5 Series FXDP Compact flat housing: up to 16 channels, channel diagnostics, configurable I/O range Series FLDP Compact flat housing: up to 16 channels, two bus connectors, common diagnostics Series FLDP Compact flat housing: up to 16 channels, one bus connector, common diagnostics Series FLDP Compact flat housing: up to 32 channels, common diagnostics Series FSDP compact flat housing: up to 16 channels for PROFIsafe, SIL 2/3 inte gr bus ated tee Dat a see sheets pag e ver Hou Ide sing o. nt-n e Typ Num ber of Inp uts per /outp ut con nec s tor Ma x. l oad [A] cur ren t Housing version 4 Num ber of out put s Housing version 3 Num ber of i npu ts Housing version 2 sion Housing version 1 – – 1,4 1,4 1,4 1,4 1,4 • • • • • • • 15 16 17 18 19 20 21 – – – 0,5 2 0,5 0,5 0,5 2 2 0,5 0,5 0,5 • • • • • • • • • – • • • 25 26 27 28 29 30 31 32 33 34 35 36 37 – 2 • • 41 42 FXDP stations – channel-related diagnostics, parameterisable I/O range FXDP-IM8-0001 FXDP-IM16-0001 FXDP-OM8-0001 FXDP-OM16-0001 FXDP-IOM88-0001 FXDP-CSG88-0001 FXDP-XSG16-0001 6825400 6825401 6825402 6825403 6825404 6825405 6825406 1 1 1 1 1 1 1 8 16 – – 8 8 2 2 4 2 2 2 2 2 2 3 4 4 4 8 16 32 – – – 8 8 8 8 16 24 20 – 1/– – 2/– 8 –/1 16 –/2 8 2/2 8 1/1 16 configurable channels FLDP stations – common diagnostics FLDP-IM8-0001 FLDP-IM16-0001 FLDP-IM32-0001 FLDP-OM8-0001 FLDP-OM8-0002 FLDP-OM16-0001 FLDP-IOM88-0001 FLDP-IOM88-0002 FLDP-IOM84-0001 FLDP-IOM84-0002 FLDP-IOM1616-0001 FLDP-IOM248-0001 FLDP-IOM2012-0001 6825320 6825326 6825332 6825321 6825331 6825327 6825322 6825323 6825330 6825342 6825338 6825333 6825339 – – – 8 8 16 8 8 4 4 16 8 12 1/– 2/– 2/– –/1 –/1 –/2 1/1 2/2 2/1 2/1 2/2 2/2 Burndy connector FSDP stations for PROFIsafe FSDP-IM16-0001 FSDP-IOM84-0001 12 /0704 6825360 6825361 5 5 16 8 – 4 2/– 2/1 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com PROFIBUS-DP Compact fieldbus stations - type code F L DP - IOM 1616 - 0001 F = Compact fieldbus station, plastic L = Economy X = High feature S = PROFIsafe PROFIBUS-DP 2 Version number Number of inputs (first two figures) Number of outputs (last two figures) IM = input module OM = output module IOM = input/output module For FXDP stations only: CSG = input and output via one connector XSG = parameterisable I/O range Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 13 /0704 PROFIBUS-DP Compact fieldbus stations - Series FXDP General information The fieldbus stations, series FXDP, allow direct connection of up to 16 inputs/ outputs to the PROFIBUS-DP. Glass-fibre reinforced flat plastic housings and the fully encapsulated module electronics guarantee protection degree IP67. Therefore these stations are particularly suited for use in harsh industrial environments. The station supports transmission rates of up to 12 Mbps and adjusts automatically to the transmission speed determined by the master. The PROFIBUS-DP address is adjusted via three coded rotary switches in a range of 1...126. The switches are located under a transparent protective cover. Operating and load voltage are fed separately, so that the load voltage UL can be disabled individually. Thus it is ensured that the module electronics and all inputs continue operation when the outputs are turned off. Therefore, the load supply diagnostic function can also be disabled via configuration. Supply failures of less than 2.5 ms are compensated and thus do not lead to module malfunction. It is also ensured that voltage recovery cannot result in generation of faulty signals. General technical data Characteristics extended diagnostics, connector-specific short-circuit diagnostics of the sensor supply voltage, channel-specific short-circuit diagnostics of the outputs, complete diagnostic data according to standard via the PROFIBUS-DP, channel-related display of status and errors via LEDs, diagnostics can be mapped to user data area (diagnostic inputs) Adjustment PROFIBUS-DP address Transmission rate 1...126 (decimal) adjustable via three coded rotary switches 9.6 kbps up to 12 Mbps, automatic LED indications Bus (dual colour LED) Power (dual colour LED) Inputs (dual colour LED) Outputs (dual colour LED) green: communication, red: no communication green: operational, OFF: UB < 18 VDC, red: UL < 18V (modules with digital outputs) green: ON, red: short-circuit green: ON, red: short-circuit Connections PROFIBUS Power supply Inputs/outputs nickel-plated brass connectors 1 x male M12 connector (IN), 1 x female M12 connector (OUT), 5-pole, reverse-keyed 1 x 7/8” male connector (IN), 1 x 7/8” female connector (OUT), 5-pole 8 female M12 x 1 connectors, 5-pole Housing PA6-GF30, glass-fibre reinforced plastic housing with encapsulated electronics and nickel-plated brass connectors via 4 through-holes, Ø 5.4 mm IP67 according to EN 60068-2-6, 2-27 to EN 61000-6-2, IEC 61000-6-4 Mounting Degree of protection (IEC 60529/EN 60529) Vibration and shock testing EMC Temperature range – Operating temperature – Storage and transport temperature Dimensions 0 °C to +55 °C (+32 °F to +131 °F) -25 °C to +70 °C (-13 °F to +158 °F) 220.5 x 62.4 x 27 (H x W x D) Approvals Area of application according to ATEX Directives 14 /0704 II 3G EEx nA IIC T4 X EC Ex directive 94/9/EG Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com PROFIBUS-DP Compact fieldbus station FXDP-IM8-0001 8 inputs 27 13 • 8 x 1 inputs • Extended diagnostics • Short-circuit diagnostics of inputs per connector • Diagnostics can be mapped to user data area • Fully encapsulated plastic housing • Degree of protection IP67 13 C3 C1 C0 Ui 0 1 2 3 In SF 1 0 x100 SF x10 2 3 4 5 6 Bus 8 7 FXDP-IM8-0001 Power 1 0 9 60,4 42 C2 1 0 9 x1 2 3 8 7 4 5 6 U0 C6 C5 210,5 4 5 220,5 6 7 Out C7 5,4 • General information: see page 14 C4 Type Ident-no. Configuration file FXDP-IM8-0001 6825400 TU0_ff1f.gsd (downloadable via the internet under www.turck.com) Operating voltage U B Internal current consumption (via UB) 18...30 VDC < 70 mA Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Switching current limitation Input time delay Switching frequency Potential isolation (8) pnp 3-wire sensors/2-wire sensors 18...30 VDC < 120 mA per connector, short-circuit protected 2 mA / 4 mA 6 mA 2.5 ms < 250 Hz to bus I/O data mapping C1P4 connector 1, pin 4, (0 = OFF, 1 = ON) SC common short-circuit indication (0 = OK, 1= fault) SC3 short-circuit indication: channel 3 Con 2 overload sensor voltage: connector 2 U B < 18 VDC UB Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Input Byte 0 C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 Diagnosis 3 ) Byte 0 – – – – – SC 7 SC 6 SC 5 SC 4 SC 3 UL SC 1 SC Byte 1 UB SC 2 Byte 2 SC 15 SC 14 SC 13 SC 12 SC 11 SC 10 SC 9 SC 8 Byte 3 Con 7 Con 6 Con 0 Con 5 Con 4 Con 3 Con 2 SC 0 Con 1 Bit is not used Wiring diagrams Bus line1) Inputs 3 wire pnp sensors Male 4 ( ) BK 1 (+) BN 2 M12 x 1 connectors 1) 3) Female 2 3 (–) BU 5 PE Operating voltage 3 1 4 5 1 2 3 4 5 = 5 VDC ) = Bus-A = GND = Bus-B = shield Male 2 2 1 5 4 3 3 5 4 M12 x 1 connectors Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Reverse-keyed according to PNO guidelines 2) Female bus connector only The manufacturer-specific diagnostics can be fully mapped to the user data area via the configuration menu. Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 15 /0704 2 PROFIBUS-DP Compact fieldbus station FXDP-IM16-0001 16 inputs 27 13 • 8 x 2 inputs • Extended diagnostics • Short-circuit diagnostics of inputs per connector • Diagnostics can be mapped to user data area • Fully encapsulated plastic housing • Degree of protection IP67 13 C3 C1 C0 Ui 0 1 2 3 In SF 1 0 x100 SF x10 2 3 4 5 6 Bus 8 7 FXDP-IM16-0001 Power 1 0 9 60,4 42 C2 1 0 9 x1 2 3 8 7 4 5 6 U0 C6 C5 210,5 4 5 220,5 6 7 Out C7 5,4 • General information: see page 14 C4 Type Ident-no. Configuration file FXDP-IM16-0001 6825401 TU1_ff1f.gsd (downloadable via the internet under www.turck.com) Operating voltage U B Internal current consumption (via UB) 18...30 VDC < 70 mA Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Switching current limitation Input time delay Switching frequency Potential isolation (16) pnp 3-wire sensors/2-wire sensors 18...30 VDC < 120 mA per connector, short-circuit protected 2 mA / 4 mA 6 mA 2.5 ms < 250 Hz to bus I/O data mapping C1P4 connector 1, pin 4, (0 = OFF, 1 = ON) SC common short-circuit indication (0 = OK, 1= fault) SC3 short-circuit indication: channel 3 Con 2 overload sensor voltage: connector 2 U B < 18 VDC UB Input Diagnosis 3 ) Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Byte 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Byte 1 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 Byte 0 – – – – – UB UL SC Byte 1 SC 7 SC 6 SC 5 SC 4 SC 3 SC 2 SC 1 SC 0 Byte 2 SC 15 SC 14 SC 13 SC 12 SC 11 SC 10 SC 9 SC 8 Byte 3 Con 7 Con 6 Con 0 Con 5 Con 4 Con 3 Con 2 Bit 1 Con 1 Bit 0 Bit is not used Wiring diagrams Bus line1) Inputs 3 wire pnp sensors Male Female 2 3 BU – 5 PE 4 BK 1 BN + 3 1 2 WH 3 BU – M12 x 1 connectors 1) 3) Operating voltage 4 5 1 2 3 4 5 = 5 VDC ) = Bus-A = GND = Bus-B = shield Male 2 2 1 5 4 3 3 5 4 M12 x 1 connectors Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Reverse-keyed according to PNO guidelines 2) Female bus connector only The manufacturer-specific diagnostics can be fully mapped to the user data area via the configuration menu. 16 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com PROFIBUS-DP Compact fieldbus station FXDP-OM8-0001 8 outputs 27 13 • 8 x 1 outputs (max. 1.4 A per output) • Extended diagnostics • Short-circuit diagnostics of the outputs per channel • Diagnostics can be mapped to user data area • Fully encapsulated plastic housing • Degree of protection IP67 13 C3 C1 C0 Ui 0 1 2 3 In SF 1 0 x100 SF x10 2 3 4 5 6 Bus 8 7 FXDP-OM8-0001 Power 1 0 9 60,4 42 C2 1 0 9 x1 2 3 8 7 4 5 6 U0 C6 C5 210,5 4 5 220,5 6 7 Out C7 5,4 C4 • General information: see page 14 Type Ident-no. Configuration file FXDP-OM8-0001 6825402 TU2_ff1f.gsd (downloadable via the internet under www.turck.com) Operating/Load supply U B/U L Internal current consumption (via UB) 18...30 VDC < 70 mA Output circuits Output voltage (via UL) Output current Switching frequency Galvanic isolation (8) DC actuators 18...30 VDC 1.4 A per output, (ED = 50 %), short-circuit protection < 250 Hz to bus I/O data mapping C1P4 connector 1, pin 4, (0 = OFF, 1 = ON) SC common short-circuit indication (0 = OK, 1= fault) SC3 short-circuit indication: channel 3 Con 2 overload sensor voltage: connector 2 U B < 18 VDC UB UL U L < 18 VDC Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Output Byte 0 C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 Diagnosis 3 ) Byte 0 – – – – – SC 7 SC 6 SC 5 SC 4 SC 3 UL SC 1 SC Byte 1 UB SC 2 Byte 2 SC 15 SC 14 SC 13 SC 12 SC 11 SC 10 SC 9 SC 8 Byte 3 Con 7 Con 6 Con 0 Con 5 Con 4 Con 3 Con 2 SC 0 Con 1 Bit is not used Wiring diagrams Bus line1) Outputs DC actuator 5 PE 2 3 (–) BU M12 x 1 connectors 1) 3) Male Female 2 4 (+) BK 1 Operating/load voltage 3 1 4 5 1 2 3 4 5 = 5 VDC = Bus-A = GND = Bus-B = shield Male 2 2) 1 5 4 3 3 5 4 M12 x 1 connectors Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Reverse-keyed according to PNO guidelines 2) Female bus connector only The manufacturer-specific diagnostics can be fully mapped to the user data area via the configuration menu. Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 17 /0704 2 PROFIBUS-DP Compact fieldbus station FXDP-OM16-0001 16 outputs 27 13 • 8 x 2 outputs (max. 1.4 A per output) • Extended diagnostics • Short-circuit diagnostics of the outputs per channel • Diagnostics can be mapped to user data area • Fully encapsulated plastic housing • Degree of protection IP67 13 C3 C1 C0 Ui 0 1 2 3 In SF 1 0 x100 SF x10 2 3 4 5 6 Bus 8 7 FXDP-OM16-0001 Power 1 0 9 60,4 42 C2 1 0 9 x1 2 3 8 7 4 5 6 U0 C6 C5 210,5 4 5 220,5 6 7 Out C7 5,4 C4 • General information: see page 14 Type Ident-no. Configuration file FXDP-OM16-0001 6825403 TU3_ff1f.gsd (downloadable via the internet under www.turck.com) Operating/ Load supply UB/U L Internal current consumption (via UB) 18...30 VDC < 70 mA Output circuits Output voltage (via UL) Output current Switching frequency Galvanic isolation (16) DC actuators 18...30 VDC 1.4 A per output, (ED = 35 %), short-circuit protection < 250 Hz to bus I/O data mapping C1P4 connector 1, pin 4, (0 = OFF, 1 = ON) SC common short-circuit indication (0 = OK, 1= fault) SC3 short-circuit indication: channel 3 Con 2 overload sensor voltage: connector 2 U B < 18 VDC UB UL U L < 18 VDC Bit 7 Output Diagnosis 3 ) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Byte 1 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 UB UL SC 1 SC Byte 0 – – – – – Byte 1 SC 7 SC 6 SC 5 SC 4 SC 3 Byte 2 SC 15 SC 14 SC 13 SC 12 SC 11 SC 10 SC 9 SC 8 Byte 3 Con 7 Con 6 Con 0 SC 2 Con 5 Con 4 Con 3 Con 2 SC 0 Con 1 Bit is not used Wiring diagrams Bus line1) Outputs DC actuator 5 PE 2 WH + 3 BU – M12 x 1 connectors 1) 3) Male Female 2 4 BK + 1 Operating/load voltage 3 1 4 5 1 2 3 4 5 = 5 VDC ) = Bus-A = GND = Bus-B = shield Male 2 2 1 5 4 3 3 5 4 M12 x 1 connectors Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Reverse-keyed according to PNO guidelines 2) Female bus connector only The manufacturer-specific diagnostics can be fully mapped to the user data area via the configuration menu. 18 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com PROFIBUS-DP Compact fieldbus station FXDP-IOM88-0001 8 inputs/8 outputs 27 13 • 4 x 2 inputs • 4 x 2 outputs (max. 1.4 A per output) • Extended diagnostics • Short-circuit diagnostics of inputs per connector • Short-circuit diagnostics of the outputs per channel • Diagnostics can be mapped to user data area • Fully encapsulated plastic housing • Degree of protection IP67 13 C2 C3 C0 Ui 0 1 2 3 In SF 1 0 x100 SF x10 2 3 4 5 6 Bus 8 7 FXDP-IOM88-0001 Power 1 0 9 60,4 42 C1 1 0 9 x1 2 3 8 7 4 5 6 U0 C6 C5 210,5 4 220,5 5 6 7 Out C7 5,4 C4 • General information: see page 14 Type Ident-no. Configuration file FXDP-IOM88-0001 6825404 TU4_ff1f.gsd (downloadable via the internet under www.turck.com) Operating/ Load voltage U B/U L Internal current consumption (via UB) 18...30 VDC < 70 mA Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Switching current limitation Input time delay Switching frequency Potential isolation (8) pnp 3-wire sensors/2-wire sensors 18...30 VDC < 120 mA per connector, short-circuit protected 2 mA / 4 mA 6 mA 2.5 ms < 250 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Galvanic isolation (8) DC actuators 18...30 VDC 1.4 A per output, (ED = 50 %), short-circuit protection < 250 Hz to bus I/O data mapping C1P4 connector 1, pin 4, (0 = OFF, 1 = ON) SC common short-circuit indication (0 = OK, 1= fault) SC3 short-circuit indication: channel 3 Con 2 overload sensor voltage: connector 2 UB U B < 18 VDC UL U L < 18 VDC Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Input Byte 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Output Byte 0 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 – – – – – SC 7 SC 6 SC 5 SC 4 SC 3 UL SC 1 SC Byte 1 UB SC 2 Byte 2 SC 15 SC 14 SC 13 SC 12 SC 11 SC 10 SC 9 SC 8 Byte 3 Con 7 Con 6 Con 0 Diagnosis 3 ) Byte 0 Con 5 Con 4 Con 3 Con 2 SC 0 Con 1 Bit is not used Wiring diagrams Inputs Outputs 3 wire pnp sensors Bus line1) DC actuator Male 4 BK 5 PE 4 BK + 1 BN + 1 2 WH 2 WH + 3 BU – 3 BU – M12 x 1 connectors Female 2 3 BU – 5 PE Operating/load voltage 3 1 4 5 1 2 3 4 5 = 5 VDC ) = Bus-A = GND = Bus-B = shield Male 2 2 1 5 4 3 3 5 4 M12 x 1 connectors Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors 1) 3 Reverse-keyed according to PNO guidelines 2) Female bus connector only ) The manufacturer-specific diagnostics can be fully mapped to the user data area via the configuration menu. Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 19 /0704 2 PROFIBUS-DP Compact fieldbus station FXDP-CSG88-0001 8 inputs/8 outputs 27 13 • 8 x 1 inputs • 8 x 1 outputs (max. 1.4 A per output) • Extended diagnostics • Short-circuit diagnostics of inputs per connector • Short-circuit diagnostics of the outputs per channel • Diagnostics can be mapped to user data area • Fully encapsulated plastic housing • Degree of protection IP67 13 C3 C1 C0 Ui 0 1 2 3 In SF 1 0 x100 SF x10 2 3 4 5 6 Bus 8 7 Power 1 0 9 60,4 42 C2 FXDP-CSG88-0001 1 0 9 x1 2 3 8 7 4 5 6 5,4 U0 C6 C5 210,5 4 5 220,5 6 7 Out C7 C4 • General information: see page 14 Type Ident-no. Configuration file FXDP-CSG88-0001 6825405 TU6_ff1f.gsd (downloadable via the internet under www.turck.com) Operating/Load voltage UB/UL Internal current consumption (via UB) 18...30 VDC < 70 mA Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Switching current limitation Input time delay Switching frequency Potential isolation (8) pnp 3-wire sensors/2-wire sensors 18...30 VDC < 120 mA per connector, short-circuit protected 2 mA / 4 mA 6 mA 2.5 ms < 250 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Galvanic isolation (8) DC actuators 18...30 VDC 1.4 A per output, (ED = 50 %), short-circuit protection < 250 Hz to bus I/O data mapping C1P4 connector 1, pin 4, (0 = OFF, 1 = ON) SC common short-circuit indication (0 = OK, 1= fault) SC3 short-circuit indication: channel 3 Con 2 overload sensor voltage: connector 2 UB U B < 18 VDC UL U L < 18 VDC Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Input Byte 0 C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 Output Byte 0 C7P2 C6P2 C5P2 C4P2 C3P2 C2P2 C1P2 C0P2 Diagnosis 3 ) Byte 0 – – – – – UB UL SC Byte 1 SC 7 SC 6 SC 5 SC 4 SC 3 SC 2 SC 1 SC 0 Byte 2 SC 15 SC 14 SC 13 SC 12 SC 11 SC 10 SC 9 SC 8 Byte 3 Con 7 Con 6 Con 0 Con 5 Con 4 Con 3 Con 2 Con 1 Bit is not used Wiring diagrams Inputs/outputs Bus line1) 3 wire pnp sensors/DC actuator Male 4 ( ) BK 1 (+) BN 2 3 1 4 M12 x 1 connectors 1) 3) Female 2 3 (–) BU 5 PE Operating/load voltage 5 1 2 3 4 5 = 5 VDC ) = Bus-A = GND = Bus-B = shield Male 2 2 1 5 4 3 3 5 4 M12 x 1 connectors Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Reverse keyed according to PNO guidelines 2) Female bus connector only The manufacturer-specific diagnostics can be fully mapped to the user data area via the configuration menu. 20 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com PROFIBUS-DP Compact fieldbus station FXDP-XSG16-0001 16 configurable channels 27 13 • • • • 13 C3 C1 C0 • Ui 0 1 2 3 In SF 1 0 x100 SF x10 2 3 4 5 6 Bus 8 7 Power 1 0 9 60,4 42 C2 • FXDP-XSG16-0001 1 0 9 x1 2 3 8 7 4 5 6 U0 C6 C5 210,5 4 5 220,5 6 7 Out C7 5,4 • • C4 16 configurable channels Configurable user data area Extended diagnostics Short-circuit diagnostics of inputs per connector Short-circuit diagnostics of the outputs per channel Diagnostics can be mapped to user data area Fully encapsulated plastic housing Degree of protection IP67 • General information: see page 14 Further information: see page 22 Type Ident-no. Configuration file FXDP-XSG16-0001 6825406 TU6_ff1f.gsd (downloadable via the internet under www.turck.com) Operating/ Load voltage U B/U L Internal current consumption (via UB) 18...30 VDC < 70 mA Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Switching current limitation Input time delay Switching frequency Potential isolation (n) pnp 3-wire sensors/2-wire sensors 18...30 VDC < 120 mA per connector, short-circuit protected 2 mA / 4 mA 6 mA 2.5 ms < 250 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Galvanic isolation (16-n) DC-Aktuatoren 18...30 VDC 1.4 A per output, (ED = 35 %), short-circuit protection < 250 Hz to bus I/O data mapping C1P4 connector 1, pin 4, (0 = OFF, 1 = ON) SC common short-circuit indication (0 = OK, 1= fault) SC3 short-circuit indication: channel 3 Con 2 overload sensor voltage: connector 2 UB U B < 18 VDC UL U L < 18 VDC Input 2) Output 2) Diagnosis 1) Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Byte 1 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 Byte 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Byte 1 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 Byte 0 – – – – – SC 7 SC 6 SC 5 SC 4 SC 3 UL SC 1 SC Byte 1 UB SC 2 Byte 2 SC 15 SC 14 SC 13 SC 12 SC 11 SC 10 SC 9 SC 8 Byte 3 Con 7 Con 6 Con 0 Con 5 Con 4 Con 3 Con 2 Con 1 SC 0 1)The 2) manufacturer-specific diagnostics can be fully mapped to the user data area via the configuration menu. Each channel can be defined as a digital input (standard, inverted, diagnosis) or as an output via the configuration menu. Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 21 /0704 2 PROFIBUS-DP 001 6-0 8-0 001 SG1 SG8 FXD P-X P-C M8 FXD FXD P-O P-IO M1 8-0 001 6-0 01 -00 M8 P-O P-IM FXD ✔ FXD 8 Bit IN FXD User data area FXD P-IM 16- 8-0 000 001 1 Configuration options 001 FXDP-XSG16-0001 Configuration/comment ✔ I per connector ✔ I/I per connector ✔ O per connector ✔ O/O per connector ✔ I/I or O/O per connector ✔ I/O per connector 8 Bit IN, 8 Bit DIAG ✔ I/DIAG 5) per connector 8 Bit OUT, 8 Bit DIAG ✔ O/DIAG 5) per connector 12 Bit IN, 4 Bit OUT ✔ I/I or O/O per connector n Bit IN, 16-n Bit OUT (PROG Mode) ✔ channel as IN, inverted IN, DIAG IN or OUT configurable n Bit IN, 16-n Bit OUT (AUTO Mode) ✔ outputs are read back ✔ diagnostics reproduced in user data area ✔ 16 Bit IN ✔ 8 Bit OUT ✔ 16 Bit OUT ✔ 8 Bit IN, 8 Bit OUT ✔ 8 Bit IN, 8 Bit OUT ✔ AddOn: DIAG mapped ✔ ✔ ✔ ✔ ✔ Wiring diagrams Inputs Outputs 3 wire pnp sensors Inputs/outputs DC actuator 3 wire pnp sensor/ DC actuator 3 BU – 5 PE 5 PE 4 BK 4 BK + 1 BN + 1 2 WH 2 WH + 3 BU – 3 BU – Male 3 (–) BU 5 PE 4 ( ) BK 1 (+) BN 2 Bus3) Operating/load voltage 4 5 3 Female 2 1 = GND 2 2 3 1 4 5 = GND = PE = UB = UL 1 3 Female Male 2 4 5 3 4 1 2 1 3 4 5 5 = = = = = 5 VDC 4) A line 1 GND B line shield 5 2 3 4 3 (–) BU 5 PE 4 (+) BK 1 (+) BN 2 ( ) WH M12 x 1 connectors M12 x 1 connectors M12 x 1 connectors 7/8" connectors M12 x 1 connectors 3 ) Reverse-keyed according to PROFIBUS guidelines 4) Female bus connector only 5) Pin 2 is used for monitoring the sensor/actuator line. The inverted signal is read at pin 2. An non-actuated input creates the channel diagnosis "wire-break at pin 2 and pin 4“ of the respective connection. 22 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 2 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 23 /0704 PROFIBUS-DP Compact fieldbus stations - Series FLDP General information The fieldbus stations, series FLDP, are designed for direct connection of up to 32 inputs/outputs to the PROFIBUS-DP. Glass-fibre reinforced flat plastic housings and the fully encapsulated module electronics guarantee protection degree IP67. Therefore these stations are particularly suited for use in harsh industrial environments. The station supports transmission rates of up to 12 Mbps and adjusts automatically to the transmission speed determined by the master. The PROFIBUS-DP address is adjusted via two coded rotary switches in a range of 1...99. The switches are located under a transparent protective cover. Operating and load voltage are fed separately to the device, so that the load voltage UL can be disabled individually. Thus it is ensured that the module electronics and all inputs continue operation when the outputs are turned off. The third rotary switch is used to disable the load voltage diagnostics. General technical data Characteristics load voltage diagnostics can be disabled via rotary switch, common short-circuit indication Adjustments PROFIBUS-DP address Load voltage diagnostics Transmission rate 1...99 (decimal) adjustable via two coded rotary switches can be disabled via coded rotary switch (modules with digital outputs only) 9.6 kbps up to 12 Mbps, automatic LED indications – Bus (dual colour LED) – Power (dual colour LED) – Inputs – Outputs – Common short-circuit indication green: communication, red: no communication green: operational, OFF: UB < 18 VDC red: UL < 18 V (modules with digital outputs only) green: ON green: ON red: short-circuit at one input Connections PROFIBUS Power supply Inputs/outputs – FLDP-IOM2012-0001 only: nickel-plated brass connectors M12 x 1 connectors, reverse-keyed 7/8" connector, 5-pole female M12 x 1 connectors; 5-pole 2 x 19-pole Burndy connectors Housing material PA6-GF30, glass-fibre reinforced plastic housing with encapsulated electronics and nickel-plated connectors via 4 through-holes, Ø 5.4 mm IP67 (NEMA 1, 3, 4, 12, 13) according to EN 60068-2-6, 2-27 0 °C to +55 °C (+32 °F to +131 °F) Mounting Degree of protection (IEC 60529/EN 60529) Vibration and shock testing Temperature range Dimensions – Modules with 8, 12 and 16 channels – Modules with 32 channels 24 /0704 220.5 x 62.4 x 27 (H x W x D) 220.5 x 115 x 27 (H x W x D) Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com PROFIBUS-DP Compact fieldbus station FLDP-IM8-0001 8 inputs 27 13 • 8 x 1 inputs • Common short-circuit indication of inputs • Fully encapsulated plastic housing • Degree of protection IP67 13 C2 C3 C1 SC C0 0 Ui 1 2 3 In • General information: see page 24 1 0 9 2 3 4 5 6 Power 2 3 x1 8 7 Bus 1 0 9 Slave Address (0-99) x10 8 7 60,4 42 FLDP-IM8-0001 4 5 6 4 C6 C5 210,5 Uo 220,5 5 6 7 Out C7 C4 SC Type Ident-no. Configuration file FLDP-IM8-0001 6825320 TRCKFF10.gsd (downloadable via the internet under www.turck.com) Operating voltage U B Internal current consumption (via UB) 18...30 VDC < 110 mA Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (8) pnp 3-wire sensors/2-wire sensors 18...30 VDC < 500 mA per 4 inputs, short-circuit protected 2 mA / 4 mA 2.5 ms < 250 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4, (0 = OFF, 1 = ON) SC common short-circuit indication of the inputs, I > 500 mA (0 = OK, 1= fault) U B < 18 VDC UB 2 5,4 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Input Byte 0 C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 Diagnosis Byte 0 – – – – – UB – SC Wiring diagrams Bus line1) Inputs Male 3 wire pnp sensors 4 ( ) BK 3 1 (+) BN 2 Reverse-keyed according to PNO guidelines 1 4 M12 x 1 connectors 1) Female 2 3 (–) BU 5 PE Operating voltage 5 1 2 3 4 5 = 5 VDC 2) = Bus-A = GND = Bus-B = shield M12 x 1 connectors 2) Male 2 1 5 4 3 4 5 3 Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Female bus connector only Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 25 /0704 PROFIBUS-DP Compact fieldbus station FLDP-IM16-0001 16 inputs 27 13 • 8 x 2 inputs • Common short-circuit indication of inputs • Fully encapsulated plastic housing • Degree of protection IP67 13 C2 C3 SC C0 C1 0 Ui 1 2 3 In • General information: see page 24 1 0 9 2 3 4 5 6 Power 2 3 x1 8 7 Bus 1 0 9 Slave Address (0-99) x10 8 7 60,4 42 FLDP-IM16-0001 4 5 6 4 C6 C5 210,5 Uo 220,5 5 6 7 Out C7 5,4 C4 SC Type Ident-no. Configuration file FLDP-IM16-0001 6825326 TRCKFF12.gsd (downloadable via the internet under www.turck.com) Operating voltage U B Internal current consumption (via UB) 18...30 VDC < 110 mA Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (16) pnp 3-wire sensors/2-wire sensors 18...30 VDC < 500 mA per 8 inputs, short-circuit protected 2 mA / 4 mA 2.5 ms < 250 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4, (0 = OFF, 1 = ON) SC common short-circuit indication of the inputs, I > 500 mA (0 = OK, 1= fault) UB < 18 VDC UB Input Diagnosis Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Byte 1 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 Byte 0 – – – – – – SC UB Wiring diagrams Bus line1) Inputs Male 3 wire pnp sensors Female 2 3 BU – 5 PE 4 BK 3 1 BN + 1 2 WH 4 3 BU – M12 x 1 connectors 1) Reverse-keyed according to PNO guidelines 26 /0704 Operating voltage 5 1 2 3 4 5 = 5 VDC 2) = Bus-A = GND = Bus-B = shield M12 x 1 connectors 2) Male 2 1 5 4 3 4 5 3 Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Female bus connector only Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com PROFIBUS-DP Compact fieldbus station FLDP-IM32-0001 32 inputs 27 13 • 16 x 2 inputs • Common short-circuit indication of inputs • Fully encapsulated plastic housing • Degree of protection IP67 13 C0 C4 SC 0 C1 C5 1 3 C2 C6 2 C3 C7 In Ui • General information: see page 24 1 0 9 2 3 FLDP-IM 32-0001 8 9 10 11 4 5 6 Power 2 3 x1 8 7 Bus 1 0 9 2 4 5 6 7 4 5 6 42 Slave Address (0-99) x10 60,4 8 7 115 Uo Out 5,4 12 13 14 15 C11 C10 C9 C8 C15 C14 C13 C12 SC 210,5 220,5 Type Ident-no. Configuration file FLDP-IM32-0001 6825332 TRCKFF16.gsd (downloadable via the internet under www.turck.com) Operating voltage U B Internal current consumption (via UB) 18...30 VDC < 110 mA (from operating voltage) Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (32) pnp 3-wire sensors/2-wire sensors 18...30 VDC < 500 mA per 8 inputs, short-circuit protected 2 mA / 4 mA 2.5 ms < 250 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4, (0 = OFF, 1 = ON) SC common short-circuit indication of the inputs, I > 500 mA (0 = OK, 1= fault) U B < 18 VDC UB Input Diagnosis Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Byte 1 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 Byte 2 C11P2 C11P4 C10P2 C10P4 C9P2 C9P4 C8P2 C8P4 Byte 3 C15P2 C15P4 C14P2 C14P4 C13P2 C13P4 C12P2 C12P4 Byte 0 – – – – – UB – SC Wiring diagrams Bus line1) Inputs 3 wire pnp sensors Male Female 2 3 BU – 5 PE 4 BK 3 1 BN + 1 2 WH 4 3 BU – M12 x 1 connectors 1) Reverse-keyed according to PNO guidelines Operating voltage 5 1 2 3 4 5 = 5 VDC 2) = Bus-A = GND = Bus-B = shield M12 x 1 connectors 2) Male 2 1 5 4 3 4 5 3 Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Female bus connector only Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 27 /0704 PROFIBUS-DP Compact fieldbus station FLDP-OM8-0001 8 outputs 27 13 • 8 x 1 outputs (max. 0,5 A per output) • Load voltage diagnostics can be disabled via coded rotary switches • Fully encapsulated plastic housing • Degree of protection IP67 13 C3 C2 C0 C1 Ui 0 1 2 3 In 1 0 9 2 3 4 5 6 Power 2 3 x1 8 7 Bus 1 0 9 Slave Address (0-99) x10 8 7 60,4 42 FLDP-OM 8-0001 4 5 Off 6 Diag UL • General information: see page 24 On 5,4 Uo C6 C5 210,5 4 5 220,5 6 7 Out C7 C4 Type Ident-no. Configuration file FLDP-OM8-0001 6825321 TRCKFF11.gsd (downloadable via the internet under www.turck.com) Operating/Load voltage UB/UL Internal current consumption (via UB) 18...30 VDC < 150 mA Output circuits Output voltage (via UL) Output current Switching frequency Galvanic isolation (8) DC actuators 18...30 VDC 0.5 A per output, short-circuit protection < 250 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) UL UL < 18 VDC UB < 18 VDC UB Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 C2P4 C1P4 C0P4 UB UL Output Byte 0 C7P4 C6P4 C5P4 C4P4 C3P4 Diagnosis Byte 0 – – – – – – Wiring diagrams Bus line1) Outputs DC actuator 5 PE Male 1 3 3 (–) BU 28 /0704 1 4 M12 x 1 connectors Reverse-keyed according to PNO guidelines Female 2 4 (+) BK 2 1) Operating/load voltage 5 1 2 3 4 5 = 5 VDC 2) = Bus-A = GND = Bus-B = shield M12 x 1 connectors 2) Male 2 1 5 4 3 4 5 3 Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Female bus connector only Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com PROFIBUS-DP Compact fieldbus station FLDP-OM8-0002 8 outputs 27 13 • 8 x 1 outputs (max. 2 A per output) • Load voltage diagnostics can be disabled via coded rotary switches • Fully encapsulated plastic housing • Degree of protection IP67 13 C3 C2 C0 C1 Ui 0 1 2 3 In 1 0 9 2 3 4 5 6 • General information: see page 24 Power 2 3 x1 8 7 Bus 1 0 9 Slave Address (0-99) x10 8 7 60,4 42 FLDP-OM8-0002 4 5 Off 6 Diag UL On 5,4 Uo C6 C5 210,5 4 5 220,5 6 7 Out C7 2 C4 Type Ident-no. Configuration file FLDP-OM8-0002 6825331 TRCKFF1A.gsd (downloadable via the internet under www.turck.com) Operating/Load voltage U B/U L Internal current consumption (via UB) 18...30 VDC < 150 mA Output circuits Output voltage (via UL) Output current Switching frequency Galvanic isolation (8) DC actuators 18...30 VDC 2 A per output, 50 % ED, short-circuit protection < 250 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) UL U L < 18 VDC U B < 18 VDC UB Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 C2P4 C1P4 C0P4 UB UL Output Byte 0 C7P4 C6P4 C5P4 C4P4 C3P4 Diagnosis Byte 0 – – – – – – Wiring diagrams Bus line1) Outputs DC actuator 5 PE Male 4 (+) BK 1 3 3 (–) BU 1 4 M12 x 1 connectors Reverse-keyed according to PNO guidelines Female 2 2 1) Operating/load voltage 5 1 2 3 4 5 = 5 VDC ) = Bus-A = GND = Bus-B = shield M12 x 1 connectors 2) Male 2 2 1 5 4 3 4 5 3 Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Female bus connector only Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 29 /0704 PROFIBUS-DP Compact fieldbus station FLDP-OM16-0001 16 outputs 27 13 • 8 x 2 outputs (max. 0.5 A per output) • Load voltage diagnostics can be disabled via coded rotary switches • Fully encapsulated plastic housing • Degree of protection IP67 13 C3 C2 C1 C0 Ui 0 1 2 3 In 1 0 9 2 3 4 5 6 FLDP-OM16-0001 4 5 Off 6 Power 2 3 x1 8 7 Bus 1 0 9 Slave Address (0-99) x10 8 7 60,4 42 Diag UL • General information: see page 24 On 5,4 Uo C6 C5 210,5 4 5 220,5 6 7 Out C7 C4 Type Ident-no. Configuration file FLDP-OM16-0001 6825327 TRCKFF13.gsd (downloadable via the internet under www.turck.com) Operating/Load voltage UB/UL Internal current consumption (via UB) 18...30 VDC < 150 mA Output circuits Output voltage (via UL) Output current Switching frequency Galvanic isolation (16) DC actuators 18...30 VDC 0.5 A per output, short-circuit protection < 250 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) UL UL < 18 VDC UB < 18 VDC UB Bit 7 Output Diagnosis Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Byte 1 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 Byte 0 – – – – – UB UL – Wiring diagrams Bus line1) Outputs DC actuator 5 PE Male 3 2 WH + 3 BU – 30 /0704 1 4 M12 x 1 connectors Reverse-keyed according to PNO guidelines Female 2 4 BK + 1 1) Operating/load voltage 5 1 2 3 4 5 = 5 VDC ) = Bus-A = GND = Bus-B = shield M12 x 1 connectors 2) Male 2 2 1 5 4 3 4 5 3 Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Female bus connector only Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com PROFIBUS-DP Compact fieldbus station FLDP-IOM88-0001 8 inputs/8 outputs 27 13 • 8 x 1 inputs/ 8 x 1 outputs (max. 0.5 A per output) • Common short-circuit indication of inputs • Load voltage diagnostics can be disabled via coded rotary switches • Fully encapsulated plastic housing • Degree of protection IP67 13 C2 C3 C1 SC C0 Ui 0 1 2 3 In 1 0 9 2 3 4 5 6 Power 2 3 x1 8 7 Bus 1 0 9 Slave Address (0-99) x10 8 7 60,4 42 4 5 Off 6 Diag UL On 5,4 Uo C6 C5 210,5 4 220,5 5 6 7 Out C7 C4 • General information: see page 24 Type Ident-no. Configuration file FLDP-IOM88-0001 6825322 TRCKFF14.gsd (downloadable via the internet under www.turck.com) Operating/Load voltage UB/UL Internal current consumption (via UB) 18...30 VDC < 150 mA Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (8) pnp 3-wire sensors/2-wire sensors 18...30 VDC < 500 mA per 4 inputs, short-circuit protected 2 mA / 4 mA 2.5 ms < 250 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (8) DC actuators 18...30 VDC 0.5 A per output, short-circuit protection < 250 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4, (0 = OFF, 1 = ON) SC common short-circuit indication of the inputs, I > 500 mA (0 = OK, 1= fault) U L < 18 VDC UL UB U B < 18 VDC Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Input Byte 0 C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 Output Byte 0 C7P2 C6P2 C5P2 C4P2 C3P2 Diagnosis Byte 0 – – – – – C2P2 C1P2 C0P2 UB UL SC Wiring diagrams Bus line1) Inputs/outputs 3 wire pnp sensors/DC actuator Male 3 (–) BU 5 PE 4 ( ) BK 1 (+) BN 3 1 4 M12 x 1 connectors Reverse-keyed according to PNO guidelines Female 2 2 1) Operating/load voltage 5 1 2 3 4 5 = 5 VDC ) = Bus-A = GND = Bus-B = shield M12 x 1 connectors 2) Male 2 2 1 5 4 3 4 5 3 Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Female bus connector only Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 31 /0704 2 PROFIBUS-DP Compact fieldbus station FLDP-IOM88-0002 8 inputs/8 outputs 27 13 • 4 x 2 inputs/ 4 x 2 outputs (max. 0.5 A per output) (inputs on left connector, outputs on right connector) • Common short-circuit indication of inputs • Load voltage diagnostics can be disabled via coded rotary switches • Fully encapsulated plastic housing • Degree of protection IP67 13 C2 C3 C1 SC C0 Ui 0 1 2 3 In 1 0 9 2 3 4 5 6 Power 2 3 x1 8 7 Bus 1 0 9 Slave Address (0-99) x10 8 7 60,4 42 FLDP-IOM88-0002 4 5 Off 6 Diag UL On 5,4 Uo C6 C5 210,5 4 220,5 5 6 7 Out C7 C4 • General information: see page 24 Type Ident-no. Configuration file FLDP-IOM88-0002 6825323 TRCKFF15.gsd (downloadable via the internet under www.turck.com) Operating/Load voltage UB/UL Internal current consumption (via UB) 18...30 VDC < 150 mA Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (8) pnp 3-wire sensors/2-wire sensors 18...30 VDC < 500 mA per 8 inputs, short-circuit protected 2 mA / 4 mA 2.5 ms < 250 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (8) DC actuators 18...30 VDC 0.5 A per output, short-circuit protection < 250 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4, (0 = OFF, 1 = ON) SC common short-circuit indication of the inputs, I > 500 mA (0 = OK, 1= fault) UL < 18 VDC UL UB UB < 18 VDC Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Input Byte 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Output Byte 0 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 Diagnosis Byte 0 – – – – – UB UL SC Wiring diagrams Inputs Bus line1) Outputs 3 wire pnp sensor DC actuator Male 5 PE 4 BK 4 BK + 1 BN + 1 2 WH 2 WH + 3 BU – 3 BU – 3 Reverse-keyed according to PNO guidelines 32 /0704 1 4 M12 x 1 connectors 1) Female 2 3 BU – 5 PE Operating/load voltage 5 1 2 3 4 5 = 5 VDC ) = Bus-A = GND = Bus-B = shield M12 x 1 connectors 2) Male 2 2 1 5 4 3 4 5 3 Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Female bus connector only Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com PROFIBUS-DP Compact fieldbus station FLDP-IOM84-0001 8 inputs/4 outputs 27 13 • 4 x 2 inputs/ 4 x 1 outputs (max. 2 A per output) (inputs on left connector, outputs on right connector) • Common short-circuit indication of inputs • Load voltage diagnostics can be disabled via coded rotary switches • Fully encapsulated plastic housing • Degree of protection IP67 13 C3 C2 C1 SC C0 Ui 0 1 2 3 In 1 0 9 2 3 4 5 6 FLDP-IOM84-0001 4 5 Off 6 Power 2 3 x1 8 7 Bus 1 0 9 Slave Address (0-99) x10 8 7 60,4 42 Diag UL On 5,4 Uo C6 C5 210,5 4 5 220,5 6 7 Out C7 C4 • General information: see page 24 Type Ident-no. Configuration file FLDP-IOM84-0001 6825330 TRCKFF1B.gsd (downloadable via the internet under www.turck.com) Operating/load voltage UB/UL Internal current consumption (via UB) 18...30 VDC < 150 mA Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (8) pnp 3-wire sensors/2-wire sensors 18...30 VDC < 500 mA per 8 inputs, short-circuit protected 2 mA / 4 mA 2.5 ms < 250 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (4) DC actuators 18...30 VDC 2 A per output, short-circuit protection < 250 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4, (0 = OFF, 1 = ON) SC common short-circuit indication of the inputs, I > 500 mA (0 = OK, 1= fault) U L < 18 VDC UL UB U B < 18 VDC Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 C0P4 Input Byte 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 Output Byte 0 – C7P4 – C6P4 – C5P4 – Diagnosis Byte 0 – – – – – UB C4P4 UL SC Wiring diagrams Inputs Bus line1) Outputs 3 wire pnp sensor Male DC actuator 4 BK 5 PE 4 (+) BK 1 BN + 1 2 WH 2 3 BU – 3 (–) BU 3 Reverse-keyed according to PNO guidelines 1 4 M12 x 1 connectors 1) Female 2 3 BU – 5 PE Operating/load voltage 5 1 2 3 4 5 = 5 VDC ) = Bus-A = GND = Bus-B = shield M12 x 1 connectors 2) Male 2 2 1 5 4 3 4 5 3 Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Female bus connector only Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 33 /0704 2 PROFIBUS-DP Compact fieldbus station FLDP-IOM84-0002 8 inputs/4 outputs 27 13 • 4 x 2 inputs/ 4 x 1 outputs (max. 2 A per output) (inputs on left connector, outputs on right connector) • Common short-circuit indication of inputs • Load voltage diagnostics can be disabled via coded rotary switches • Fully encapsulated plastic housing • Degree of protection IP67 13 C3 C2 C1 SC C0 Ui 0 1 2 3 1 0 9 2 3 4 5 6 FLDP-IOM 84-0002 4 5 Off 6 Power 2 3 x1 8 7 Bus 1 0 9 Slave Address (0-99) x10 8 7 60,4 42 Diag UL 5,4 On Uo C6 C5 210,5 4 5 220,5 6 7 Out C7 C4 • General information: see page 24 Type Ident-no. Configuration file FLDP-IOM84-0002 6825342 TRCKFF1B.gsd (downloadable via the internet under www.turck.com) Operating/load voltage UB/UL Internal current consumption (via UB) 18...30 VDC < 150 mA Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (8) pnp 3-wire sensors/2-wire sensors 18...30 VDC < 500 mA per 8 inputs, short-circuit protected 2 mA / 4 mA 2.5 ms < 250 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (4) DC actuators 18...30 VDC 2 A per output, short-circuit protection < 250 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4, (0 = OFF, 1 = ON) SC common short-circuit indication of the inputs, I > 500 mA (0 = OK, 1= fault) UL < 18 VDC UL UB UB < 18 VDC Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 C0P4 Input Byte 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 Output Byte 0 – C7P4 – C6P4 – C5P4 – Diagnosis Byte 0 – – – – – UB C4P4 UL SC Wiring diagrams Inputs Bus line1) Outputs 3 wire pnp sensor DC actuator Female 3 BU – 5 PE 4 BK 5 PE 1 2 3 4 5 4 (+) BK 1 BN + 1 2 WH 2 3 BU – 3 (–) BU M12 x 1 connectors 1) Reverse-keyed according to PNO guidelines 34 /0704 Operating/load voltage = 5 VDC ) = Bus-A = GND = Bus-B = shield M12 x 1 connectors 2) Male 2 2 1 5 4 3 4 5 3 Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Female bus connector only Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com PROFIBUS-DP Compact fieldbus station FLDP-IOM1616-0001 16 inputs/16 outputs 27 13 • 8 x 2 inputs/ 8 x 2 outputs (max. 0.5 A per output) (inputs on left connector, outputs on right connector) • Common short-circuit indication of inputs • Load voltage diagnostics can be disabled via coded rotary switches • Fully encapsulated plastic housing • Degree of protection IP67 13 C1 C5 2 1 7 6 5 C0 C4 SC 0 C2 C6 3 C3 C7 Ui In 1 0 9 2 3 4 4 5 6 FLDP-IOM 1616-0001 8 9 10 11 4 5 Off 6 Power 2 3 x1 8 7 Bus 1 0 9 42 Slave Address (0-99) x10 60,4 8 7 Diag UL 115 On 5,4 Uo Out 12 13 14 15 • General information: see page 24 C11 C10 C9 C8 C15 C14 C13 C12 210,5 220,5 Type Ident-no. Configuration file FLDP-IOM1616-0001 6825338 TRCKFF18.gsd (downloadable via the internet under www.turck.com) Operating/load voltage UB/UL Internal current consumption (via UB) 18...30 VDC < 150 mA Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (16) pnp 3-wire sensors/2-wire sensors 18...30 VDC < 500 mA per 8 inputs, short-circuit protected 2 mA / 4 mA 2.5 ms < 250 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (16) DC actuators 18...30 VDC 0.5 A per output, short-circuit protection < 250 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4, (0 = OFF, 1 = ON) SC common short-circuit indication of the inputs, I > 500 mA (0 = OK, 1= fault) U L < 18 VDC UL UB U B < 18 VDC Input Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Byte 1 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 Byte 0 C11P2 C11P4 C10P2 C10P4 C9P2 C9P4 C8P2 C8P4 Byte 1 C15P2 C15P4 C14P2 C14P4 C13P2 C13P4 C12P2 C12P4 Byte 0 Output Diagnosis Byte 0 – – – – – UB UL SC Wiring diagrams Inputs Bus line1) Outputs 3 wire pnp sensor Male DC actuator 4 BK 5 PE 4 BK + 1 BN + 1 2 WH 2 WH + 3 BU – 3 BU – 3 Reverse-keyed according to PNO guidelines 1 4 M12 x 1 connectors 1) Female 2 3 BU – 5 PE Operating/load voltage 5 1 2 3 4 5 = 5 VDC ) = Bus-A = GND = Bus-B = shield M12 x 1 connectors 2) Male 2 2 1 5 4 3 4 5 3 Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Female bus connector only Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 35 /0704 2 PROFIBUS-DP Compact fieldbus station FLDP-IOM 248-0001 24 inputs/8 outputs 27 13 • 12 x 2 inputs/ 4 x 2 outputs (max. 0.5 A per output) (inputs on left connector, outputs on right connector) • Common short-circuit indication of inputs • Load voltage diagnostics can be disabled via coded rotary switches • Fully encapsulated plastic housing • Degree of protection IP67 13 C1 C5 2 1 7 6 5 C0 C4 SC 0 C2 C6 3 C3 C7 Ui In 1 0 9 2 3 4 4 5 6 FLDP-IOM 248-0001 8 9 10 11 4 5 Off 6 Power 2 3 x1 8 7 Bus 1 0 9 42 Slave Address (0-99) x10 60,4 8 7 Diag UL 115 On 5,4 Uo Out 12 13 14 15 • General information: see page 24 C11 C10 C9 C8 C15 C14 C13 C12 SC 210,5 220,5 Type Ident-no. Configuration file FLDP-IOM248-0001 6825333 TRCKFF17.gsd (downloadable via the internet under www.turck.com) Operating/load voltage UB/UL Internal current consumption (via UB) 18...30 VDC < 150 mA Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (24) pnp 3-wire sensors/2-wire sensors 18...30 VDC < 500 mA per 8 inputs, short-circuit protected 2 mA / 4 mA 2.5 ms < 250 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (8) DC actuators 18...30 VDC 0.5 A per output, short-circuit protection < 250 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4, (0 = OFF, 1 = ON) SC common short-circuit indication of the inputs, I > 500 mA (0 = OK, 1= fault) UL < 18 VDC UL UB UB < 18 VDC Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Byte 1 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 Byte 2 C11P2 C11P4 C10P2 C10P4 C9P2 C9P4 C8P2 C8P4 Output Byte 0 C15P2 C15P4 C14P2 C14P4 C13P2 C13P4 C12P2 C12P4 Diagnosis Byte 0 Input Byte 0 – – – – – UB UL SC Wiring diagrams Inputs Bus line1) Outputs 3 wire pnp sensor DC actuator Male 4 BK + 5 PE 4 BK 1 BN + 1 2 WH 2 WH + 3 BU – 3 BU – 3 Reverse-keyed according to PNO guidelines 36 /0704 1 4 M12 x 1 connectors 1) Female 2 3 BU – 5 PE Operating/load voltage 5 1 2 3 4 5 = 5 VDC ) = Bus-A = GND = Bus-B = shield M12 x 1 connectors 2) Male 2 2 1 5 4 3 4 5 3 Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Female bus connector only Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com PROFIBUS-DP Compact fieldbus station FLDP-IOM2012-0001 20 inputs/12 outputs 27 13 • 20 inputs/ 12 outputs (max. 0.5 A per output) • Common short-circuit indication of inputs • Load voltage diagnostics can be disabled via coded rotary switches • Fully encapsulated plastic housing • Degree of protection IP67 13 SC X1 Ui I O 2 1 2 3 0 3 4 0 1 5 I O 6 5 6 7 4 7 In 1 0 9 2 3 4 5 6 Power X1 X2 2 3 x1 8 7 Bus 1 0 9 42 Slave Address (0-99) x10 60,4 8 7 4 5 Off 6 Diag UL 115 On 5,4 Uo I 10 1 2 0 11 0 3 I 8 9 1 I O 3 2 5 6 4 7 Out • General information: see page 24 Further information: see page 38 X2 220,5 SC 210,5 Type Ident-no. FLDP-IOM2012-0001 6825339 Operating / Load voltage UB/UL Internal current consumption 18...30 VDC < 150 mA Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (20) pnp 3-wire sensors/2-wire sensors 18...30 VDC < 500 mA per 8/12 inputs, short-circuit protected 2 mA / 4 mA 2.5 ms < 250 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (12) DC actuators 18...30 VDC 0.5 A per output, short-circuit protection < 250 Hz to bus I/O data mapping Abbreviations/Designations: X1I7, X1I6, ... (see table on next page) SC common short-circuit indication of the inputs, I > 500 mA (0 = OK, 1= fault) UL U L < 18 VDC UB U B < 18 VDC Input Output Diagnosis Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 X1I7 X1I6 X1I5 X1I4 X1I3 X1I2 X1I1 X1I0 Byte 1 X2I7 X2I6 X2I5 X2I4 X2I3 X2I2 X2I1 X2I0 Byte 2 – – – – X2I11 X2I10 X2I9 X2I8 Byte 0 X1O7 X1O6 X1O5 X1O4 X1O3 X1O2 X1O1 X1O0 Byte 1 – – – – X2O3 X2O2 X2O1 X2O0 Byte 0 – – – – – UB UL SC Wiring diagrams Bus line1) Burndy connector L K J M U T H A Male B P C V R D G 3 E F 1 4 Female Burndy connector 1) Reverse-keyed according to PNO guidelines Female 2 N S Operating/load voltage 5 1 2 3 4 5 = 5 VDC ) = Bus-A = GND = Bus-B = shield M12 x 1 connectors 2) Male 2 2 1 5 4 3 4 5 3 Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Female bus connector only Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 37 /0704 2 PROFIBUS-DP FLDP-IOM2012-0001 Connection of input/output module FLDP-IOM2012 – junction 8FKS5P3 Passive junction 8FKS5P3 ( X1 ) 7 8 5 6 Input/output module FLDP-IOM2012 Ui 3 4 X1 1 2 7 8 5 6 3 4 1 2 Uo Power 0 0 0 8 1 1 1 9 2 2 2 10 3 3 3 11 I O Passive junction 8FKS5P3 ( X2 ) X1 I I X2 4 4 4 0 5 5 5 1 6 6 6 7 7 I O I O 2 7 Bus X2 3 FLDP-IOM 2012-0001 Diag UL Slave Address (0-99) 1 0 9 2 3 8 7 4 5 6 1 0 9 x10 2 3 8 7 4 5 Off 6 On x1 Out In Connection: input/output module FLDP-IOM2012 – junction 8FKS5P3 Burndy FLDP-IOM2012 8FKS5P3 Block diagram/Pin configuraton Passive junction module 8FKS5P3 Input/output Connector 1 ...................... 8 C T bytes A B S R M L H G D C U T P N K J F E V 38 /0704 X1 + – I0 I1 I2 I3 I4 I5 I6 I7 O0 O1 O2 O3 O4 O5 O6 O7 PE X2 + – I0 I1 I2 I3 I4 I5 I6 I7 I8 I9 I10 I11 O0 O1 O2 O3 PE X1 + – S7/4 S7/2 S5/4 S5/2 S3/4 S3/2 S1/4 S1/2 S8/4 S8/2 S6/4 S6/2 S4/4 S4/2 S2/4 S2/2 PE X2 + – S7/4 S7/2 S5/4 S5/2 S3/4 S3/2 S1/4 S1/2 S8/4 S8/2 S6/4 S6/2 S4/4 S4/2 S2/4 S2/2 PE X1 X2 I0.0 I0.1 I0.2 I0.3 I0.4 I0.5 I0.6 I0.7 O0.0 O0.1 O0.2 O0.3 O0.4 O0.5 O0.6 O0.7 I1.0 I1.1 I1.2 I1.3 I1.4 I1.5 I1.6 I1.7 I2.0 I2.1 I2.2 I2.3 O1.0 O1.1 O1.2 O1.3 YE YE 2 5 1 3 2 5 1 4 3 4 YE YE D GN + – PE A B V U M12 x 1 connector 2 (+) 1 (–) 3 5 (PE) 4 (A) Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 2 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 39 /0704 PROFIBUS-DP Compact fieldbus stations for PROFIsafe - Series FSDP General information The fieldbus stations, series FSDP, allow direct connection to the PROFIBUS-DP. The station is designed for connection of SIL 2/3 parameterisable inputs and for safe control of outputs. SIL 2/SIL 3 (i.e. Safety Integrated Level) is a classification according to IEC/EN 61508, which defines the communication safety level and specifies that the devices connected via the PROFIBUS communicate so safely, that they are suited for safety-related applications. Glass-fibre reinforced flat plastic housings and the fully encapsulated module electronics guarantee protection degree IP67. Therefore these stations are particularly suited for use in harsh industrial environments. The station with the „PROFIsafe“ telegram supports transmission rates of up to 12 Mbps and adjusts automatically to the transmission speed determined by the master. The station’s address is set between 1... 99 via two coded rotary switches. The switches are located under a transparent protective cover. The F address, which is required by the system, is set via four rotary switches (1...9999). General technical data Characteristics areas of application: safety-related systems; e. g.: emergency stop buttons, door limt switches Adjustments PROFIBUS-DP address F address Transmission rate 1...99 (decimal) adjustable via two rotary switches 1...9999 adjustable via 4 coded rotary switches, accessible under protective cover 9.6 kbps up to 12 Mbps, automatic LED indications Bus (dual colour LED) Power SIL 3 mode Inputs Outputs green: communication, red: no communication, red flashing: shutdown after error green: operational, OFF: supply voltage outside admissible range green: module has been parameterised for SIL 3; OFF: module has been parameterised for SIL 2. green flashing: module parameterisation not yet concluded or F functions of module not active green: ON green: ON Connections PROFIBUS Power supply Inputs/outputs 1 x male M12 connector (IN), 1 x female M12 connector (OUT), 5-pole, reverse-keyed 1 x 7/8” male connector (IN), 1 x 7/8” female connector (OUT), 5-pole 8 x M12 x 1 connectors Housing Mounting Degree of protection (IEC 60529/EN 60529) Vibration and shock testing Temperature range Dimensions 40 /0704 PA6-GF30, glass-fibre reinforced plastic housing with encapsulated electronics and nickel-plated brass connectors via 4 through-holes, Ø 5,4mm IP67 (NEMA 1, 3, 4, 12, 13) according to EN 60068-2-6/2-27 -25 °C to +55 °C (-13 °F to +131 °F) 220.5 x 115 x 27 (H x W x D) Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com PROFIBUS-DP Compact fieldbus station FSDP-IM16-0001 16 inputs 27 13 13 C3 C2 0 1 I0 I1 I2 I3 7 8 9 0 1 6 5 4 6 5 4 7 8 7 8 3 2 3 2 x1 9 0 1 F-Address x10 7 8 7 8 3 2 3 2 x1000 x100 6 5 4 6 5 4 Bus 3 2 5,4 9 0 1 9 0 1 U I8 4 5 6 7 C5 I9 I10 I11 I12 I13 I14 I15 C6 220,5 I4 I5 I6 I7 SIL SIL 2 3 Out C7 2 Power 4 SIL3 Mode 5 9 0 1 6 FSDP-IM16-0001 3 2 DP-Address 4 x10 x1 5 9 0 1 6 • General information: see page 40 U I0 I1 I2 I3 I4 I5 I6 I7 7 42 C0 8 60,5 C1 2 3 SIL SIL 2 3 In 115 • 16 inputs SIL 2/ 8 inputs SIL 3 • Failsafe PROFIsafe station • Fully encapsulated plastic housing • Degree of protection IP67 C4 210,5 Type Ident-no. Configuration file FSDP-IM16-0001 6825360 TRCKFF33.gsd (downloadable via the internet under www.turck.com) Operating voltage U B Internal current consumption (via UB) 20...28 VDC < 200 mA Input circuits (16) mechanical contacts SIL 2, operating in the normally closed mode (8) mechanical contacts SIL 3, operating in the normally closed mode 24 VDC < 10 mA, short-circuit protection 2 mA / 8 mA 10 Hz to bus Input voltage Input current Switching threshold OFF/ON Switching frequency Galvanic isolation Approvals IEC/EN 61508-SIL 3 EN 954-1, CAT 4 TÜV certificate no. Z10040653279001 I/O data mapping Abbreviations/Designations: SIL 3 C0 connector 0 (0 = OFF, 1 = ON) Note: SIL 3 requires per channel pin 2 and pin 4 SIL 2 C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) SIL 3 Input Byte 0 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 C6 C5 C4 C3 C2 C1 C0 Byte 1 – Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Byte 1 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 SIL 2 Input Bit 7 C7 – – – – – – – Further data including diagnostics details are contained in our manual "IP67 modules for safety-related application“ D300772. Wiring diagrams Bus line1) Inputs Mechanical contacts Male 3– Female 2 4 1+ A 5+ 2 B Operating voltage 3 1 4 3– 5 1 2 3 4 5 = 5 VDC ) = Bus-A = GND = Bus-B = shield M12 x 1 connectors 1) Reverse-keyed according to PNO guidelines 2) Male 2 2 1 5 4 3 4 5 3 Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Female bus connector only Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 41 /0704 PROFIBUS-DP Compact fieldbus station FSDP-IOM84-0001 8 inputs/4 outputs 27 13 13 C3 C2 0 1 I0 I1 I2 I3 Power 9 0 1 6 5 4 6 5 4 7 8 7 8 3 2 3 2 x1 9 0 1 F-Address 7 8 7 8 3 2 3 2 x10 6 5 4 6 5 4 x1000 x100 x1 Bus 3 2 FSDP-IOM84-0001 4 SIL3 Mode 5 9 0 1 6 DP-Address 7 8 x10 x1 3 2 4 x10 Slave Address (0-99) 5 9 0 1 6 • General information: see page 39 U I0 I1 I2 I3 I4 I5 I6 I7 7 42 C0 8 60,4 C1 2 3 SIL SIL 3 2 In 115 • 8 inputs SIL2/ 4 inputs SIL 3/ 4 outputs (max. 2 A per output) • Failsafe PROFIsafe station • Fully encapsulated plastic housing • Degree of protection IP67 9 0 1 9 0 1 4 C5 U C6 O0 5 6 7 C7 O1 O2 O3 SIL SIL 3 2 Out 5,4 C4 210,5 220,5 Type Ident-no. Configuration file FSDP-IOM84-0001 6825361 TRCKFF31.gsd (downloadable via the internet under www.turck.com) Operating voltage UB/UL Internal current consumption (via UB) 20...28 VDC < 200 mA Input circuits (8) mechanical contacts SIL 2, operating in the normally closed mode (4) mechanical contacts SIL 3, operating in the normally closed mode 24 VDC < 10 mA, short-circuit protection 2 mA / 8 mA 10 Hz to bus Input voltage Input current Switching threshold OFF/ON Switching frequency Galvanic isolation Output circuits Output voltage (via UL) Output current Switching frequency Galvanic isolation a t a d y r a n i im l e r p t e e h s (4) DC actuators 18...30 VDC 2 A per output, short-circuit protection 50 Hz (with ohmic load) to bus Approvals (pending) IEC/EN 61508-SIL 3 EN 954-1, CAT 4 I/O data mapping Abbreviations/Designations: SIL3 C0 connector 0 (0 = OFF, 1 = ON) Note: SIL3 requires per channel pin 2 and pin 4 SIL2 C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) SIL 3 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Input Byte 0 – – – – C3 C2 C1 C0 Output Byte 0 – – – – C7P4 C6P4 C5P4 C4P4 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Input Byte 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Output Byte 0 – – – – C7P4 C6P4 C5P4 C4P4 SIL 2 Wiring diagrams Inputs Outputs Mechanical contacts DC actuator Bus line1) Male A 5+ 2 B 3– Female 2 3– 4 1+ 3 4 BK + 5 Operating/load voltage 1 1 4 2 3 BU – 5 1 2 3 4 5 = 5 VDC 2) = Bus-A = GND = Bus-B = shield M12 x 1 connectors 1) Reverse-keyed according to PNO guidelines 42 /0704 2) Male 2 1 5 4 3 4 5 3 Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Female bus connector only Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 2 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 43 /0704 DeviceNet™ Compact fieldbus stations - device overview Housing version 1 Housing version 2 Pow er of o supp ly c utp onc uts ept Dat a see sheets pag e Ma x. l oad cur ren t [A ] /pn con p s e n nec sor tab le npn Num ber of inp uts per /outp ut con nec s tor Num ber of out put s sing ver Ide Hou o. nt-n e Typ Num ber of i npu ts Series FDNP Compact flat housing with up to 16 channels, connection for actuator supply, common diagnostics (series SE) or channel diagnostics (series LX) sion Series FDNL Compact flat housing with up to 16 channels, common diagnostics (series SE) or channel diagnostics (series LX) FDN... stations LX series – channel diagnostics (separate short-circuit and wire-break diagnostics of inputs and outputs) FDNL-L0800-T 6603335 1 8 – 1/– npn/pnp – – 46 FDNL-L1600-T 6602335 1 16 – 2/– npn/pnp – – 47 FDNP-CPG88-TT 6603324 2 8 8 1/1 pnp 0.5 Aux 48 FDNP-L0404G-TT 6603327 2 4 4 1/1 npn/pnp 0.5 Aux 49 FDNP-L0808G-TT 6602389 2 8 8 2/2 npn/pnp 0.5 Aux 50 FDNP-P1204G-TT 6602672 2 12 4 2/2 pnp 0.5 Aux 51 FDNP-P0808H-TT 6603329 2 8 8 2/2 pnp 2 Aux 52 FDNP-L0808H-TT 6603328 2 8 8 2/2 npn/pnp 2 Aux 53 FDN... stations SE series – channel diagnostics (common short-circuit diagnostics of inputs and outputs) FDNL-S0800-T 6603336 1 8 – 1/– pnp – – 54 FDNL-N0800-T 6603671 1 8 – 1/– npn – – 55 FDNL-S1600-T 6603316 1 16 – 2/– pnp – – 56 FDNL-N1600-T 6603672 1 16 – 2/– npn – – 57 FDNL-CSG88-T 6603351 1 8 8 1/1 pnp 0,5 bus 58 FDNP-S0404G-TT 6603331 2 4 4 1/1 pnp 0,5 Aux 59 FDNP-S0808G-TT 6603348 2 8 8 2/2 FDNP-XSG16-TT 6603323 2 16 configurable channels FDNP-S0008G-TT 6603673 2 – 8 FDNP-S0008H-TT 6603674 2 – 8 44 /0704 pnp 0,5 Aux 60 pnp 0,5 Aux 61 –/1 – 0,5 Aux 62 –/1 – 1,4 Aux 63 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com DeviceNet™ Compact fieldbus stations - type code F DN P - L 0404 G - T T F = compact fieldbus station, plastic DN = DeviceNet™ Load voltage connection: T = 7/8", male and female P = 8 I/O connections/load voltage/ 220 mm long L = 8 I/O connections/197 mm long/ DeviceNet™ pin configuration: T = 7/8" male and female 3 G = outputs 0.5 A H = outputs 1.4 or 2.0 A Number of inputs (first two figures) Number of outputs (last two figures) L = npn/pnp, channel-specific wire-break and short-circuit monitoring P = pnp, channel-specific wire-break and short-circuit monitoring S = pnp, common short-circuit indication of inputs N = npn, common short-circuit indication CPG = combined input/output per connector XSG = parameterisable I/O range Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 45 /0704 DeviceNet™ Compact fieldbus stations - Series FDN... General information The fieldbus stations, series FDN, allow direct connection of up to 16 inputs/ outputs to DeviceNet™. Glass-fibre reinforced plastic housings and the fully encapsulated module electronics guarantee protection degree IP67. Therefore these stations are particularly suited for use in harsh industrial environments. The stations support transmission rates of up to 500 kbps. The station’s address and communication rate can be set either via hardware or software (DeviceNet™ configuration tool). General technical data Hardware adjustments are established with rotary switches; but please note that a software or voltage reset is required to adopt the settings. FDN type fieldbus stations support all DeviceNet™ communication modes, incl. "Poll“, "Strobe“, "Cyclic“, "Change of State (COS)“ and "UCMM“. The comprehensive diagnostic functions comprise individual or common short-circuit or wire-break indication; the deluxe version (LX) provides channel-specific short-circuit and wire-break diagnostics, whereas the standard version (SE) features common short-circuit diagnostics of the inputs and outputs. Characteristics – Deluxe version (LX): – Standard version (SE): channel-specific short-circuit and wire-break diagnostics of inputs and outputs common short-circuit diagnostics of inputs and outputs Adjustments DeviceNet™ address Transmission rate 0...63 (decimal) adjustable via two coded rotary switches automatic LED indications Inputs Outputs Errors (dual colour LED- deluxe version only) Module status (dual colour LED) Network status (dual colour LED) green: ON green: ON yellow: wire-break, red: short-circuit green: operational – green flashing: detection of the baud rate, red flashing: I/O short-circuit green: communication, green flashing: ready to establish communication red: communication failed, red flashing: communication time-out Connections DeviceNet™ With FDNP stations: aux power Inputs/outputs nickel-plated brass connectors 7/8" connector, 5-pole; IN and OUT 7/8" connector, 4-pole; IN and OUT female M12 x 1 connectors; 5-pole Housing PA6-GF30, glass-fibre reinforced plastic housing with encapsulated electronics and nickel-plated brass connectors via 4 through-holes, Ø 5,4mm IP67 (NEMA 1, 3, 4, 12, 13) Mounting Degree of protection Temperature range – Deluxe version (LX) – Standard version (SE): Dimensions – FDNL stations – FDNP stations -25 °C to +70 °C (-13 °F to +158 °F) -40 °C to +70 °C (-40 °F to +158 °F) Approvals CE, UL, CSA 46 /0704 197 x 60 x 27 (H x W x D) 220 x 60 x 27 (H x W x D) Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com DeviceNet™ Compact fieldbus station FDNL-L0800-T 16 inputs 35,3 27 40,3 13 13 C3 NET 42 C2 C1 C0 C7 197 C6 C5 187 C4 Type Ident-no. FDNL-L0800-T 6603335 Operating voltage U B Internal current consumption (via UB) 11...26 VDC < 100 mA (plus the sum of sensor currents) Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (8) 3-wire npn/pnp sensors or mechanical contacts 11...26 VDC < 80 mA per input, short-circuit protected 2 mA / 3...3.4 mA at 24 VDC 2.5 ms < 100 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) ISS input short-circuit status IOS input wire-break status (0 = OK, 1= fault) 8 x 1 inputs, npn/pnp Channel-specific diagnostics Fully encapsulated plastic housing Degree of protection IP67 • General information: see page 46 5,4 MOD Node Address (00-63, PGM) Data Rate (Kb) 500 AUTO 2 3 2 3 4 1 250 1 4 0 5 0 125 5 6 9 6 PGM 8 7 PGM MSD LSD 60,4 • • • • Input 3 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 Byte 1 ISS-7 ISS-6 ISS-5 ISS-4 ISS-3 ISS-2 ISS-1 ISS-0 Byte 2 IOS-7 IOS-6 IOS-5 IOS-4 IOS-3 IOS-2 IOS-1 IOS-0 Wiring diagrams Inputs Operating voltage/bus line 3-wire npn/pnp sensor 3 (–) BU 4 ( ) BK 5 PE 1 (+) BN 2 M12 x 1 connectors Male 4 5 3 Female 2 1 1 2 3 4 5 = shield =V+ =V– = CAN_H = CAN_L 2 1 3 4 5 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 47 /0704 DeviceNet™ Compact fieldbus station FDNL-L1600-T 16 inputs 35,3 27 40,3 13 13 C3 NET 42 C2 C1 C0 C7 197 C6 C5 C4 187 Type Ident-no. FDNL-L1600-T 6602335 Operating voltage U B Internal current consumption (via UB) 11...26 VDC < 140 mA (plus the sum of sensor currents) Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (16) 3-wire npn/pnp sensors or mechanical contacts 11...26 VDC < 80 mA per input, short-circuit protected 2 mA / 3...3.4 mA at 24 VDC 2.5 ms < 100 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) ISS input short-circuit status IOS input wire-break status (0 = OK, 1= fault) 8 x 2 inputs, npn/pnp Channel-specific diagnostics Fully encapsulated plastic housing Degree of protection IP67 • General information: see page 46 5,4 MOD Node Address (00-63, PGM) Data Rate (Kb) 500 AUTO 2 3 2 3 1 4 250 4 1 0 5 0 125 5 6 6 9 PGM 8 7 PGM MSD LSD 60,4 • • • • Input Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Byte 1 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 Byte 2 ISS-7 ISS-6 ISS-5 ISS-4 ISS-3 ISS-2 ISS-1 ISS-0 Byte 3 ISS-15 ISS-14 ISS-13 ISS-12 ISS-11 ISS-10 ISS-9 ISS-8 Byte 4 IOS-7 IOS-1 IOS-0 Byte 5 IOS-15 IOS-14 IOS-13 IOS-12 IOS-11 IOS-10 IOS-9 IOS-8 IOS-6 IOS-5 IOS-4 IOS-3 IOS-2 Wiring diagrams Inputs Operating voltage/bus line Male 3-wire npn/pnp sensor 3 BU – 4 BK 1 BN + 5 BN + 2 WH A 4 B 5 3 BU – M12 x 1 connectors 48 /0704 3 Female 2 1 1 2 3 4 5 = shield =V+ =V– = CAN_H = CAN_L 2 1 3 4 5 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com DeviceNet™ Compact fieldbus station FDNP-CPG88-TT 8 inputs/8 outputs 35,3 27 40,3 13 13 C3 C1 C0 AUX NET 42 C2 MOD Node Address (00-63, PGM) Data Rate (Kb) 500 AUTO 2 3 2 3 1 4 250 4 1 0 5 0 125 5 6 6 9 PGM 8 7 PGM MSD LSD 60,4 • 8 x 1 inputs, pnp 8 x 1 outputs (max. 0.5 A per output) • Auxiliary power/load supply • Channel-specific diagnostics • Fully encapsulated plastic housing • Degree of protection IP67 • General information: see page 46 5,4 C7 220,5 C6 C5 210,5 C4 Type Ident-no. FDNP-CPG88-TT 6603324 Operating voltage U B Internal current consumption (via UB) Auxiliary power UL 11...26 VDC < 140 mA (plus the sum of sensor currents) 18...26 VDC Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (8) 3-wire pnp sensors or mechanical contacts 11...26 VDC < 120 mA per input, short-circuit protected 2 mA / 3...3.4 mA at 24 VDC 2.5 ms < 100 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (8) DC actuators 18...26 VDC 0.5 A per output, short-circuit protection < 100 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 APS auxiliary power status (0 = OFF, 1 = ON) ISS input short-circuit status IOS input wire-break status OS output status (0 = OK, 1= fault) Input Output 3 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 Byte 1 ISS-7 ISS-6 ISS-5 ISS-4 ISS-3 ISS-2 ISS-1 ISS-0 Byte 2 IOS-7 IOS-6 IOS-5 IOS-4 IOS-3 IOS-2 IOS-1 IOS-0 Byte 3 OS-7 OS-6 OS-5 OS-4 OS-3 OS-2 OS-1 OS-0 Byte 4 – APS – Byte 0 C7P2 C6P2 C5P2 – C4P2 – C3P2 – – – C2P2 C1P2 C0P2 Wiring diagrams Inputs/outputs 3 wire pnp sensors/DC actuator 3 (–) BU 5 PE 4 ( ) BK 1 (+) BN 2 M12 x 1 connectors Operating voltage/bus line Male 4 5 3 Auxiliary power/load supply Female 2 1 1 2 3 4 5 = shield =V+ =V– = CAN_H = CAN_L 7/8" connectors 2 1 3 Male Female 4 1 3 5 2 4 1 2 3 4 = Aux + =E+ =E– = Aux – 3 1 4 2 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 49 /0704 DeviceNet™ Compact fieldbus station FDNP-L0404G-TT 4 inputs/4 outputs 35,3 27 40,3 13 13 C3 C1 C0 AUX NET 42 C2 MOD Node Address (00-63, PGM) Data Rate (Kb) 500 AUTO 2 3 2 3 4 1 250 4 1 0 5 0 125 5 6 6 9 PGM 8 7 PGM MSD LSD 60,4 • 4 x 1 inputs, npn/pnp 4 x 1 outputs (max. 0.5 A per output) • Auxiliary power/load supply • Channel-specific diagnostics • Fully encapsulated plastic housing • Degree of protection IP67 • General information: see page 46 5,4 C7 220,5 C6 C5 210,5 C4 Type Ident-no. FDNP-L0404G-TT 6603327 Operating voltage U B Internal current consumption (via UB) Auxiliary power UL 11...26 VDC < 140 mA (plus the sum of sensor currents) 18...26 VDC Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (4) 3-wire npn/pnp sensors or mechanical contacts 11...26 VDC < 80 mA per input, short-circuit protected 2 mA / 3...3.4 mA at 24 VDC 2.5 ms < 100 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (4) DC actuators 18...26 VDC 0.5 A per output, short-circuit protection < 100 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 APS auxiliary power status (0 = OFF, 1 = ON) ISS input short-circuit status IOS input wire-break status OOS output wire-break status OSS output short-circuit status (0 = OK, 1= fault) Bit 7 Input Output Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 – – – – C3P4 C2P4 C1P4 C0P4 Byte 1 IOS-3 IOS-2 IOS-1 IOS-0 ISS-3 ISS-2 ISS-1 ISS-0 Byte 2 OOS-3 OOS-2 OOS-1 OOS-0 OSS-3 OSS-2 OSS-1 OSS-0 Byte 3 – APS – – Byte 0 – – – – – C7P4 – – – C4P4 C5P4 C4P4 Wiring diagrams Inputs Outputs 3-wire npn/pnp sensor 3 (–) BU 4 ( ) BK 5 PE DC actuator 5 PE 1 (+) BN 1 2 3 (–) BU 2 M12 x 1 connectors 50 /0704 4 (+) BK Auxiliary power/load supply Operating voltage/bus line Male 4 5 3 Female 2 1 1 2 3 4 5 = shield =V+ =V– = CAN_H = CAN_L 7/8" connectors 2 1 3 Male Female 4 1 3 5 2 4 1 2 3 4 = Aux + =E+ =E– = Aux – 3 1 4 2 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com DeviceNet™ Compact fieldbus station FDNP-L0808G-TT 8 inputs/8 outputs 35,3 27 40,3 13 13 C3 C1 C0 AUX NET 42 C2 MOD Node Address (00-63, PGM) Data Rate (Kb) 500 AUTO 2 3 2 3 1 4 250 4 1 0 5 0 125 5 6 6 9 PGM 8 7 PGM MSD LSD 60,4 • 4 x 2 inputs, npn/pnp 4 x 2 outputs (max. 0.5 A per output) • Auxiliary power/load supply • Channel-specific diagnostics • Fully encapsulated plastic housing • Degree of protection IP67 • General information: see page 46 5,4 C7 220,5 C6 C5 210,5 C4 Type Ident-no. FDNP-L0808G-TT 6602389 Operating voltage U B Internal current consumption (via UB) Auxiliary power UL 11...26 VDC < 100 mA (plus the sum of sensor currents) 18...26 VDC Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (8) 3-wire npn/pnp sensors or mechanical contacts 11...26 VDC < 80 mA per input, short-circuit protected 2 mA / 3...3.4 mA at 24 VDC 2.5 ms < 100 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (8) DC actuators 18...26 VDC 0.5 A per output, short-circuit protection < 100 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 APS auxiliary power status (0 = OFF, 1 = ON) ISS input short-circuit status IOS input wire-break status OS output status (0 = OK, 1= fault) Input Output 3 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 Byte 1 ISS-7 ISS-6 ISS-5 ISS-4 ISS-3 ISS-2 ISS-1 ISS-0 Byte 2 IOS-7 IOS-6 IOS-5 IOS-4 IOS-3 IOS-2 IOS-1 IOS-0 Byte 3 OS-7 OS-6 OS-5 OS-4 OS-3 OS-2 OS-1 OS-0 Byte 4 – APS – Byte 0 C7P2 C6P2 C5P2 – C4P2 – C3P2 – – – C2P2 C1P2 C0P2 Wiring diagrams Inputs Outputs 3-wire npn/pnp sensor DC actuator 3 BU – 4 BK 1 BN + 5 BN + 2 WH A 5 PE B 3 BU – M12 x 1 connectors 3 (–) BU 4 ( ) BK Auxiliary power/load supply Operating voltage/bus line Male Output A 1 4 5 2 ( ) WH 3 (–) BU 3 Female 2 1 1 2 3 4 5 = shield =V+ =V– = CAN_H = CAN_L 2 1 3 Male Female 4 1 3 5 2 4 1 2 3 4 = Aux + =E+ =E– = Aux – 3 1 4 2 Output B 7/8" connectors 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 51 /0704 DeviceNet™ Compact fieldbus station FDNP-P1204G-TT 12 inputs/4 outputs 35,3 27 40,3 13 13 C3 C1 C0 AUX NET 42 C2 MOD Node Address (00-63, PGM) Data Rate (Kb) 500 AUTO 2 3 2 3 4 1 250 1 4 0 5 0 125 5 6 9 6 PGM 8 7 PGM MSD LSD 60,4 • 6 x 2 inputs, pnp 4 x 1 outputs (max. 0.5 A per output) • Auxiliary power/load supply • Channel-specific diagnostics • Fully encapsulated plastic housing • Degree of protection IP67 • General information: see page 46 5,4 C7 220,5 C6 C5 210,5 C4 Type Ident-no. FDNP-P1204G-TT 6602672 Operating voltage U B Internal current consumption (via UB) Auxiliary power UL 11...26 VDC < 100 mA (plus the sum of sensor currents) 18...26 VDC Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (12) 3-wire pnp sensors or mechanical contacts 11...26 VDC < 80 mA per input, short-circuit protected 2 mA / 3...3.4 mA at 24 VDC 2.5 ms < 100 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (4) DC actuators 18...26 VDC 0.5 A per output, short-circuit protection < 100 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 APS auxiliary power status (0 = OFF, 1 = ON) ISS input short-circuit status IOS input wire-break status OOS output wire-break status OSS output short-circuit status (0 = OK, 1= fault) Bit 7 Input Output Bit 6 Bit 5 Bit 4 C3P4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C5P2 C5P4 C3P2 Byte 1 – APS – Byte 2 ISS-7 ISS-6 ISS-5 Byte 3 Byte 4 IOS-7 IOS-0 Byte 5 OOS-3 OOS-2 OOS-1 OOS-0 IOS-11 IOS-10 IOS-9 C2P2 C2P4 C1P2 C1P4 C7P2 C7P4 C6P2 C6P4 ISS-3 ISS-2 ISS-1 ISS-0 OSS-3 OSS-2 OSS-1 OSS-0 ISS-11 ISS-10 ISS-9 ISS-8 Byte 0 IOS-6 – – – ISS-4 IOS-5 IOS-4 – IOS-3 C4P2 – IOS-2 C4P4 IOS-1 C0P2 IOS-8 C0P4 Wiring diagrams Inputs Outputs 3-wire pnp sensor DC actuator 3 BU – 4 BK 1 BN + A 5 BN + 2 WH B 5 PE 3 BU – 3 (–) BU 4 ( ) BK Male Output A 1 4 5 2 ( ) WH 3 (–) BU 3 Auxiliary power/load supply Female 2 1 1 2 3 4 5 = shield =V+ =V– = CAN_H = CAN_L 2 1 3 Male Female 4 1 3 5 2 4 1 2 3 4 = Aux + =E+ =E– = Aux – 3 1 4 2 Output B M12 x 1 connectors 52 /0704 Operating voltage/bus line 7/8" connectors 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com DeviceNet™ Compact fieldbus station FDNP-P0808H-TT 8 inputs/8 outputs 35,3 27 40,3 13 13 C3 C1 C0 AUX NET 42 C2 MOD Node Address (00-63, PGM) Data Rate (Kb) 500 AUTO 2 3 2 3 1 4 250 4 1 0 5 0 125 5 6 6 9 PGM 8 7 PGM MSD LSD 60,4 • 4 x 2 inputs, pnp 4 x 2 outputs (max. 2 A per output) • Auxiliary power/load supply • Channel-specific diagnostics • Fully encapsulated plastic housing • Degree of protection IP67 • General information: see page 46 5,4 C7 220,5 C6 C5 210,5 C4 Type Ident-no. FDNP-P0808H-TT 6603329 Operating voltage U B Internal current consumption (via UB) Auxiliary power UL 11...26 VDC < 100 mA (plus the sum of sensor currents) 18...26 VDC Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (8) 3-wire pnp sensors or mechanical contacts 11...26 VDC < 80 mA per input, short-circuit protected 2 mA / 3...3.4 mA at 24 VDC 2.5 ms < 100 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (8) DC actuators 18...26 VDC 2 A per output (8 A total current), short-circuit protection < 100 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 APS auxiliary power status (0 = OFF, 1 = ON) ISS input short-circuit status IOS input wire-break status OS output status (0 = OK, 1= fault) Input Output 3 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 Byte 1 ISS-7 ISS-6 ISS-5 ISS-4 ISS-3 ISS-2 ISS-1 ISS-0 Byte 2 IOS-7 IOS-6 IOS-5 IOS-4 IOS-3 IOS-2 IOS-1 IOS-0 Byte 3 OS-7 OS-6 OS-5 OS-4 OS-3 OS-2 OS-1 OS-0 Byte 4 – APS – Byte 0 C7P2 C6P2 C5P2 – C4P2 – C3P2 – – – C2P2 C1P2 C0P2 Wiring diagrams Inputs outputs 3-wire pnp sensor DC actuator 3 BU – 4 BK 1 BN + A 5 BN + 2 WH B 5 PE 3 BU – M12 x 1 connectors 3 (–) BU 4 ( ) BK Auxiliary power/load supply Operating voltage/bus line Male Output A 1 4 5 2 ( ) WH 3 (–) BU 3 Female 2 1 1 2 3 4 5 = shield =V+ =V– = CAN_H = CAN_L 2 1 3 Male Female 4 1 3 5 2 4 1 2 3 4 = Aux + =E+ =E– = Aux – 3 1 4 2 Output B 7/8" connectors 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 53 /0704 DeviceNet™ Compact fieldbus station FDNP-L0808H-TT 8 inputs/8 outputs 35,3 27 40,3 13 13 C3 C1 C0 AUX NET 42 C2 MOD Node Address (00-63, PGM) Data Rate (Kb) 500 AUTO 2 3 2 3 4 1 250 1 4 0 5 0 125 5 6 9 6 PGM 8 7 PGM MSD LSD 60,4 • 4 x 2 inputs, npn/pnp 4 x 2 outputs (max. 2 A per output) • Auxiliary power/load supply • Channel-specific diagnostics • Fully encapsulated plastic housing • Degree of protection IP67 • General information: see page 46 5,4 C7 220,5 C6 C5 210,5 C4 Type Ident-no. FDNP-L0808H-TT 6603328 Operating voltage U B Internal current consumption (via UB) Auxiliary power UL 11...26 VDC < 100 mA (plus the sum of sensor currents) 18...26 VDC Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (8) 3-wire npn/pnp sensors or mechanical contacts 11...26 VDC < 80 mA per input, short-circuit protected 2 mA / 3...3.4 mA at 24 VDC 2.5 ms < 100 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (8) DC actuators 18...26 VDC 2 A per output (8 A total current), short-circuit protection < 100 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 APS auxiliary power status (0 = OFF, 1 = ON) ISS input short-circuit status IOS input wire-break status OS output status (0 = OK, 1= fault) Input Output Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 Byte 1 ISS-7 ISS-6 ISS-5 ISS-4 ISS-3 ISS-2 ISS-1 ISS-0 Byte 2 IOS-7 IOS-6 IOS-5 IOS-4 IOS-3 IOS-2 IOS-1 IOS-0 Byte 3 OS-7 OS-6 OS-5 OS-4 OS-3 OS-2 OS-1 OS-0 Byte 4 – APS – Byte 0 C7P2 C6P2 C5P2 – – C4P2 C3P2 – – – C2P2 C1P2 C0P2 Wiring diagrams Inputs Outputs 3-wire npn/pnp sensor DC actuator Male 3 BU – 4 BK 1 BN + 5 BN + 2 WH A 5 PE 1 B 3 BU – 2 WH + 4 5 3 Male Female 2 1 1 2 3 4 5 = shield =V+ =V– = CAN_H = CAN_L 2 1 3 Female 4 1 3 5 2 4 1 2 3 4 = Aux + =E+ =E– = Aux – 3 1 4 2 3 BU – M12 x 1 connectors 54 /0704 4 BK + Auxiliary power/load supply Operating voltage/bus line 7/8" connectors 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com DeviceNet™ Compact fieldbus station FDNL-S0800-T 8 inputs 35,3 27 40,3 13 13 C3 NET 42 C2 C1 C0 C7 197 C6 C5 187 C4 Type Ident-no. FDNL-S0800-T 6603336 Operating voltage U B Internal current consumption (via UB) 11...26 VDC < 50 mA (plus the sum of sensor currents) Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (8) 3-wire pnp sensors or mechanical contacts 13...26 VDC < 700 mA, short-circuit protection 2 mA / 3...3.4 mA at 24 VDC 2.5 ms < 100 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) IGS common input status (0 = OK, 1= fault) 8 x 1 inputs, pnp Common diagnostics Fully encapsulated plastic housing Degree of protection IP67 • General information: see page 46 5,4 MOD Node Address (00-63, PGM) 2 3 2 3 1 4 4 1 0 5 0 5 6 6 9 8 7 PGM MSD LSD 60,4 • • • • Input 3 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 Byte 1 IGS – – – – – – – Wiring diagrams Inputs Operating voltage/bus line 3-wire pnp sensor 3 (–) BU 4 ( ) BK 5 PE 1 (+) BN 2 M12 x 1 connectors Male 4 5 3 Female 2 1 1 2 3 4 5 = shield =V+ =V– = CAN_H = CAN_L 2 1 3 4 5 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 55 /0704 DeviceNet™ Compact fieldbus station FDNL-N0800-T 8 inputs 35,3 27 40,3 13 13 C3 NET 42 C2 C1 C0 C7 197 C6 C5 187 C4 Type Ident-no. FDNL-N0800-T 6603671 Operating voltage U B Internal current consumption (via UB) 11...26 VDC < 50 mA (plus the sum of sensor currents) Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (8) 3-wire npn sensors or mechanical contacts 13...26 VDC < 700 mA, short-circuit protection 2 mA / 3...3.4 mA at 24 VDC 2.5 ms < 100 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) IGS common input status (0 = OK, 1= fault) 8 x 1 inputs, npn Common diagnostics Fully encapsulated plastic housing Degree of protection IP67 • General information: see page 46 5,4 MOD Node Address (00-63, PGM) 2 3 2 3 1 4 4 1 0 5 0 5 6 6 9 8 7 PGM MSD LSD 60,4 • • • • Input Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 Byte 1 IGS – – – – – – – Wiring diagrams Inputs Operating voltage/bus line 3-wire npn sensor 3 (–) BU 4 ( ) BK 5 PE 1 (+) BN 2 M12 x 1 connectors 56 /0704 Male 4 5 3 Female 2 1 1 2 3 4 5 = shield =V+ =V– = CAN_H = CAN_L 2 1 3 4 5 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com DeviceNet™ Compact fieldbus station FDNL-S1600-T 16 inputs 35,3 27 40,3 13 13 C3 NET 42 C2 C1 C0 C7 197 C6 C5 187 C4 Type Ident-no. FDNL-S1600-T 6603316 Operating voltage U B Internal current consumption (via UB) 11...26 VDC < 50 mA (plus the sum of sensor currents) Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (16) 3-wire pnp sensors or mechanical contacts 13...26 VDC < 700 mA, short-circuit protection 2 mA / 3...3.4 mA at 24 VDC 2.5 ms < 100 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) IGS common input status (0 = OK, 1= fault) 8 x 2 inputs, pnp Common diagnostics Fully encapsulated plastic housing Degree of protection IP67 • General information: see page 46 5,4 MOD Node Address (00-63, PGM) Data Rate (Kb) 500 AUTO 2 3 2 3 4 1 250 1 4 0 5 0 125 5 6 6 9 PGM 8 7 PGM MSD LSD 60,4 • • • • Input 3 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Byte 1 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 Byte 2 IGS – – – – – – – Wiring diagrams Inputs Operating voltage/bus line 3-wire pnp sensor Male 3 BU – 5 PE 4 BK 4 3 Female 2 1 BN + 2 WH 3 BU – M12 x 1 connectors 5 1 1 2 3 4 5 = shield =V+ =V– = CAN_H = CAN_L 2 1 3 4 5 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 57 /0704 DeviceNet™ Compact fieldbus station FDNL-N1600-T 16 inputs 35,3 27 40,3 13 13 C3 NET 42 C2 C1 C0 C7 197 C6 C5 187 C4 Type Ident-no. FDNL-N1600-T 6603672 Operating voltage U B Internal current consumption (via UB) 11...26 VDC < 50 mA (plus the sum of sensor currents) Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (16) 3-wire npn sensors or mechanical contacts 13...26 VDC < 700 mA, short-circuit protection 2 mA / 3...3.4 mA at 24 VDC 2.5 ms < 100 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) IGS common input status (0 = OK, 1= fault) 8 x 2 inputs, npn Common diagnostics Fully encapsulated plastic housing Degree of protection IP67 • General information: see page 46 5,4 MOD Node Address (00-63, PGM) Data Rate (Kb) 500 AUTO 2 3 2 3 4 1 250 1 4 0 5 0 125 5 6 6 9 PGM 8 7 PGM MSD LSD 60,4 • • • • Input Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Byte 1 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 Byte 2 IGS – – – – – – – Wiring diagrams Inputs Operating voltage/bus line 3-wire npn sensor Male 3 BU – 5 PE 4 BK 1 BN + 2 WH 3 BU – M12 x 1 connectors 58 /0704 4 5 3 Female 2 1 1 2 3 4 5 = shield =V+ =V– = CAN_H = CAN_L 2 1 3 4 5 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com DeviceNet™ Compact fieldbus station FDNL-CSG88-T 8 inputs/8 outputs 40,3 27 • 8 x 1 inputs, pnp 8 x 1 outputs (max. 0.5 A per output) • Common diagnostics • Fully encapsulated plastic housing • Degree of protection IP67 13 13 C3 C1 C0 NET 5,4 MOD Node Address (00-63, PGM) 2 3 2 3 4 1 1 4 0 5 0 5 6 9 6 8 7 PGM MSD LSD 60,4 42 C2 C7 197 C6 C5 187 • General information: see page 46 C4 Type Ident-no. FDNL-CSG88-T 6603351 Operating voltage UB Internal current consumption (via UB) 11...26 VDC < 100 mA (plus the sum of sensor currents) Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (8) 3-wire pnp sensors or mechanical contacts 13...26 VDC < 700 mA, short-circuit protection 2 mA / 3...3.4 mA at 24 VDC 2.5 ms < 100 Hz to bus Output circuits Output voltage (via UB) Output current Switching frequency Potential isolation (8) DC actuators 18...26 VDC 0.5 A per output, short-circuit protection < 100 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) OGS common output status (0 = OK, 1= fault) IGS common input status (0 = OK, 1= fault) Input Output 3 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 Byte 1 IGS OGS – – – – – – Byte 0 C7P2 C6P2 C5P2 C4P2 C3P2 C2P2 C1P2 C0P2 Wiring diagrams Inputs/outputs 3 wire pnp sensors/DC actuator 3 (–) BU 5 PE 4 ( ) BK 1 (+) BN 2 M12 x 1 connectors Operating voltage/bus line Male 4 5 3 Female 2 1 1 2 3 4 5 = shield =V+ =V– = CAN_H = CAN_L 2 1 3 4 5 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 59 /0704 DeviceNet™ Compact fieldbus station FDNP-S0404G-TT 4 inputs/4 outputs 40,3 27 13 13 C2 C3 42 C1 C0 NET Node Address (00-63, PGM) 2 3 2 3 1 4 4 1 0 5 0 5 6 6 9 8 7 PGM MSD LSD 60,4 • 4 x 1 inputs, pnp 4 x 1 outputs (max. 0.5 A per output) • Auxiliary power/load supply • Common diagnostics • Fully encapsulated plastic housing • Degree of protection IP67 • General information: see page 46 5,4 C7 220,5 C6 C5 210,5 C4 Type Ident-no. FDNP-S0404G-TT 6603331 Operating voltage UB Internal current consumption (via UB) Auxiliary power UL 11...26 VDC < 75 mA 18...26 VDC Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (4) 3-wire pnp sensors or mechanical contacts 13...26 VDC < 700 mA, short-circuit protection 2 mA / 3...3.4 mA at 24 VDC 2.5 ms < 100 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (4) DC actuators 18...26 VDC 0.5 A per output, short-circuit protection < 100 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) OGS common output status (0 = OK, 1= fault) IGS common input status (0 = OK, 1= fault) Bit 7 Bit 6 OGS – Input Byte 0 IGS Output Byte 0 – Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 – – C3P4 C2P4 C1P4 C0P4 – – C7P4 C6P4 C5P4 C4P4 Wiring diagrams Inputs Outputs 3-wire pnp sensor 3 (–) BU 4 ( ) BK 5 PE DC actuator 5 PE 2 1 (+) BN 3 (–) BU 2 M12 x 1 connectors 60 /0704 4 (+) BK 1 Auxiliary power/load supply Operating voltage/bus line Male 4 5 3 Female 2 1 1 2 3 4 5 = shield =V+ =V– = CAN_H = CAN_L 7/8" connectors 2 1 3 Male 4 5 1 2 Female 3 4 1 2 3 4 = Aux + =E+ =E– = Aux – 3 1 4 2 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com DeviceNet™ Compact fieldbus station FDNP-S0808G-TT 8 inputs/8 outputs 40,3 27 13 13 C3 NET 42 C2 C1 C0 MOD Node Address (00-63, PGM) 2 3 2 3 4 1 1 4 0 5 0 5 6 9 6 8 7 PGM MSD LSD 60,4 • 4 x 2 inputs, pnp 4 x 2 outputs (max. 0.5 A per output) • Auxiliary power/load supply • Common diagnostics • Fully encapsulated plastic housing • Degree of protection IP67 • General information: see page 46 5,4 C7 220,5 C6 C5 210,5 C4 Type Ident-no. FDNP-S0808G-TT 6603348 Operating voltage U B Internal current consumption (via UB) Auxiliary power UL 11...26 VDC < 75 mA 18...26 VDC Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (8) 3-wire pnp sensors or mechanical contacts 13...26 VDC < 700 mA, short-circuit protection 2 mA / 3...3.4 mA at 24 VDC 2.5 ms < 100 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (8) DC actuators 18...26 VDC 0.5 A per output, short-circuit protection < 100 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) OGS common output status (0 = OK, 1= fault) IGS common input status (0 = OK, 1= fault) Input Output 3 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 Byte 1 IGS OGS – – – – – – Byte 0 C7P2 C6P2 C5P2 C4P2 C3P2 C2P2 C1P2 C0P2 Wiring diagrams Inputs Outputs 3-wire pnp sensor DC actuator 3 BU – 5 PE 4 BK 1 BN + 5 PE 2 WH 3 BU – M12 x 1 connectors 3 (–) BU 4 ( ) BK Auxiliary power/load supply Operating voltage/bus line Male Output A 1 4 5 2 ( ) WH 3 (–) BU 3 Female 2 1 1 2 3 4 5 = shield =V+ =V– = CAN_H = CAN_L 2 1 3 Male Female 4 1 3 5 2 4 1 2 3 4 = Aux + =E+ =E– = Aux – 3 1 4 2 Output B 7/8" connectors 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 61 /0704 DeviceNet™ Compact fieldbus station FDNP-XSG16-TT 16 inputs or outputs 40,3 27 13 C2 C1 C0 C7 C6 C5 210,5 C4 AUX NET 42 C3 MOD Node Address (00-63, PGM) 2 3 2 3 1 4 4 1 0 5 0 5 6 6 9 8 7 PGM MSD LSD 60,4 13 • 16 configurable inputs, pnp or outputs (max. 0.5 A per output) • High flexibility through freely configurable inputs and outputs • Auxiliary power/load supply • Common diagnostics • Fully encapsulated plastic housing • Degree of protection IP67 5,4 220,5 • General information: see page 46 Type Ident-no. FDNP-XSG16-TT 6603323 Operating voltage U B Internal current consumption (via UB) Auxiliary power UL 11...26 VDC < 75 mA (plus the sum of sensor currents and output currents) 18...26 VDC Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (16) 3-wire pnp sensors or mechanical contacts 13...26 VDC < 700 mA, short-circuit protection 2 mA / 3...3.4 mA at 24 VDC 2.5 ms < 100 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (16) DC actuators 18...26 VDC 0.5 A per output, short-circuit protection < 100 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) OGS common output status (0 = OK, 1= fault) IGS common input status (0 = OK, 1= fault) Input Output Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Byte 1 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 Byte 2 IGS OGS – – – – – – Byte 0 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Byte 1 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 Wiring diagrams Inputs 3-wire pnp sensor Outputs Inputs/outputs DC actuator 3 wire pnp sensors/ DC actuator Male 3 (–) BU 3 BU – 5 PE 5 PE 4 BK 4 BK + 1 BN + 1 2 WH 2 WH + 3 BU – 3 BU – 5 PE 4 ( ) BK 1 (+) BN 2 Auxiliary power/load supply Operating voltage/bus line 4 5 3 Female 2 1 1 2 3 4 5 = shield =V+ =V– = CAN_H = CAN_L 2 1 3 Male Female 4 1 3 5 2 4 1 2 3 4 = Aux + =E+ =E– = Aux – 3 1 4 2 3 (–) BU 5 PE 4 (+) BK 1 (+) BN 2 ( ) WH M12 x 1 connectors 62 /0704 M12 x 1 connectors M12 x 1 connectors 7/8" connectors 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com DeviceNet™ Compact fieldbus station FDNP-S0008G-TT 8 outputs 40,3 27 13 13 C3 C1 C0 AUX NET 42 C2 MOD Node Address (00-63, PGM) 2 3 2 3 4 1 1 4 0 5 0 5 6 9 6 8 7 PGM MSD LSD 60,4 • 8 x 1 outputs (max. 0.5 A per output) • Auxiliary power/load supply • Common diagnostics • Fully encapsulated plastic housing • Degree of protection IP67 • General information: see page 46 5,4 C7 220,5 C6 C5 210,5 C4 Type Ident-no. FDNP-S0008G-TT 6603673 Operating voltage U B Internal current consumption (via UB) Auxiliary power UL 11...26 VDC < 140 mA 18...26 VDC Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (8) DC actuators 18...26 VDC 0.5 A per output, short-circuit protection < 100 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) OS-7 output status: channel 7 (0 = OK, 1= fault) 3 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Output Byte 0 C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 Input Byte 0 OS-7 OS-6 OS-5 OS-4 OS-3 OS-2 OS-1 OS-0 Wiring diagrams Operating voltage/bus line Inputs DC actuator 5 PE 4 (+) BK 1 2 3 (–) BU M12 x 1 connectors Male 4 5 3 Auxiliary power/load supply Female 2 1 1 2 3 4 5 = shield =V+ =V– = CAN_H = CAN_L 7/8" connectors 2 1 3 Male Female 4 1 3 5 2 4 1 2 3 4 = Aux + =E+ =E– = Aux – 3 1 4 2 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 63 /0704 DeviceNet™ Compact fieldbus station FDNP-S0008H-TT 8 outputs 40,3 27 13 13 C3 C1 C0 AUX NET 42 C2 MOD Node Address (00-63, PGM) 2 3 2 3 4 1 1 4 0 5 0 5 6 9 6 8 7 PGM MSD LSD 60,4 • 8 x 1 outputs (max. 1.4 A per output) • Auxiliary power/load supply • Common diagnostics • Fully encapsulated plastic housing • Degree of protection IP67 • General information: see page 46 5,4 C7 220,5 C6 C5 210,5 C4 Type Ident-no. FDNP-S0008H-TT 6603674 Operating voltage U B Internal current consumption (via UB) Auxiliary power UL 11...26 VDC < 50 mA 18...26 VDC Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (8) DC actuators 18...26 VDC 1,4 A per output (total current 8 A), short-circuit protection < 100 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) OS-7 output status: channel 7 (0 = OK, 1= fault) Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Output Byte 0 C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 Input Byte 0 OS-7 OS-6 OS-5 OS-4 OS-3 OS-2 OS-1 OS-0 Wiring diagrams Operating voltage/bus line Outputs DC actuator 5 PE 4 (+) BK 1 2 3 (–) BU M12 x 1 connectors 64 /0704 Male 4 5 3 Auxiliary power/load supply Female 2 1 1 2 3 4 5 = shield =V+ =V– = CAN_H = CAN_L 7/8" connectors 2 1 3 Male Female 4 1 3 5 2 4 1 2 3 4 = Aux + =E+ =E– = Aux – 3 1 4 2 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 3 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 65 /0704 Ethernet Compact fieldbus stations - device overview Dat a see sheets pag e Ma x. l oad cur ren t [A ] Num ber of inp uts per /outp ut con nec s tor Num ber of out put s Num ber of i npu ts Ide Typ e nt-n o. Series FENP Compact flat housing with up to 16 channels, housing with one bus connector, power supply via two 7/8" connectors, common diagnostics FENP stations – common diagnostics – pnp inputs FENP-S0800 6611038 8 – 1/– – 69 FENP-S1600 6611039 16 – 2/– – 70 FENP-S0008G 6611041 – 8 –/1 0.5 71 FENP-S0808G 6611040 8 8 2/2 0.5 72 FENP-XSG16 6611042 0.5 73 66 /0704 16 configurable channels Hans Turck GmbH & Co.KG • D–45466 Mülheim an der Ruhr • Phone 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Ethernet Compact fieldbus stations - type code F EN P - S 0808 G F = compact fieldbus station, plastic EN = Ethernet P = 8 I/O connections/load voltage/ 220 mm long G = outputs 0.5 A 4 Number of inputs (first two figures) Number of outputs (last two figures) S = pnp, common short-circuit indication of inputs, ground pin XSG = configurable I/O range Hans Turck GmbH & Co.KG • D–45466 Mülheim an der Ruhr • Phone 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 67 /0404 Ethernet Compact fieldbus stations - Series FENP General information The fieldbus stations, series FENP, allow direct connection of up to 16 inputs/ outputs to an Ethernet TCP/IP network. Glass-fibre reinforced flat plastic housings and the fully encapsulated module electronics guarantee protection degree IP67. Therefore these stations are particularly suited for use in harsh industrial environments. The stations feature common short-circuit diagnostics and support transmission rates of 10/100 Mbps. The status of the FENP stations can be called up via an integrated web server. The module is connected via one 8-pole M12 x 1 connector to the Ethernet TCP/IP network. Power is provided via a 7/8” connector and fed through via a second 7/8” connector. The module is equipped throughout with metal M12 connectors for connection of the sensor/actuator level. General technical data Characteristics Adjustments Internet protocol IP address – via DHCP/BOOTP common short-circuit diagnostics Transmission rate If the first rotary switch is set to DHCP/BOOTP, then the DHCP/BOOTP server will automatically assign a netmask, an IP and default gateway address to the module. The settings of the other rotary switches are ignored. If the first rotary switch is set to PGM, then the netmask, IP and default gateway address are assigned via software. The settings of the other rotary switches are ignored. The last three figures of the IP address are set with the three coded rotary switches. The other values of the IP address, or netmask and default gateway accord to the default settings. In order to reset the station to the default values, set all three coded rotary switches to 0. 192.168.0.0 255.255.255.0 192.168.0.1 After changing the position of the coded rotary switches, a voltage reset must be carried out 10/100 Kbps; automatic Connections Ethernet Power supply Inputs/outputs nickel-plated brass connectors 1 x female M12 x 1 connector; 8-pole 2 x 7/8" connectors 8 x female M12 x 1 connectors; 5-pole – via PGM – via coded rotary switches Reset mode IP address Netmask Default gateway LED indications Inputs outputs Power (dual colour LED) ACT/LINK MOD/NET (dual colour LED) Application layer HTTP BOOTP; DHCP MODBUS TCP EtherNet/IP Housing Mounting Degree of protection Temperature range Dimensions 68 /0704 green: ON green: ON green: operational, red: undervoltage green: connection established flashing red: common short-circuit indication, green flashing: operational, red: communication not possible website of station automatic addressing I/O data exchange I/O data exchange (in preparation) PA6-GF30, glass-fibre reinforced plastic housing with encapsulated electronics and nickel-plated brass connectors via 4 through-holes, Ø 5.4 mm NEMA 1, 3, 4, 12, 13 and IEC IP67 0 °C to +70 °C (+32 °F to +158 °F) 220.5 x 62.4 x 27 (H x W x D) Hans Turck GmbH & Co.KG • D–45466 Mülheim an der Ruhr • Phone 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Ethernet Compact fieldbus station FENP-S0800 8 inputs 27 13 • 8 x 1 inputs pnp • Common diagnostics • Status polling via integrated web server • Fully encapsulated plastic housing • Degree of protection IP67 13 C3 C2 C0 C1 I0 I1 I2 I3 1 0 9 8 7 2 3 4 5 6 • General information: see page 68 AUX 4 5 6 ACT/LNK 2 3 8 7 MOD/NET 1 0 9 60,4 42 FENP-S0800 1 0 9 2 3 8 7 4 5 6 I4 I5 220,5 I6 I7 C7 5,4 C6 C5 210,5 C4 Type Ident-no. FENP-S0800 6611038 Operating voltage U B Internal current consumption (via UB) 18...30 VDC < 150 mA Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (8) pnp 3-wire sensors/2-wire sensors 18...30 VDC 500 mA per 8 inputs 2 mA / 4 mA 2.5 ms < 250 Hz to bus 4 I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) SC common short-circuit indication I > 500 mA (0 = OK, 1= fault) Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Input Bit 8 Offset 0 – – – – – – – – Offset 1 – – – – – – – – Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 – – – – – – – SC Wiring diagrams Inputs Ethernet 3-wire pnp sensor 3 (–) BU 4 ( ) BK 5 PE 1 (+) BN 2 M12 x 1 connectors Operating/load voltage Female 5 6 7 1 4 8 3 Female Male 1 2 3 4 = n. c. = n. c. = n. c. = Tx – 5 6 7 8 = = = = Rx + Tx + n. c. Rx – 2 M12 x 1 connectors 4 5 3 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 3 1 4 5 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim an der Ruhr • Phone 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 69 /0404 Ethernet Compact fieldbus station FENP-S1600 16 inputs 27 13 • 8 x 2 inputs pnp • Common diagnostics • Status polling via integrated web server • Fully encapsulated plastic housing • Degree of protection IP67 13 C3 C2 C1 C0 I1 I0 I3 I2 I4 I5 I6 I7 1 0 9 2 3 8 7 4 5 6 4 5 6 • General information: see page 68 AUX 2 3 8 7 ACT/LNK 1 0 9 60,4 42 FENP-S1600 1 0 9 2 3 8 7 4 5 6 I9 C6 C5 210,5 I8 I11 I10 I13 220,5 I12 I14 I15 C7 5,4 C4 Type Ident-no. FENP-S1600 6611039 Operating voltage UB Internal current consumption (via UB) 18...30 VDC < 150 mA Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (16) pnp 3-wire sensors/2-wire sensors 18...30 VDC 500 mA per 16 inputs 2 mA / 4 mA 2.5 ms < 250 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) SC common short-circuit indication I > 500 mA (0 = OK, 1= fault) Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Input Offset 0 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Offset 1 – – – – – – – – – – – – – – – SC Wiring diagrams Inputs Ethernet 3-wire pnp sensor Female 3 BU – 5 PE 4 BK 1 BN + 70 /0704 5 2 WH 4 3 BU – 8 3 M12 x 1 connectors Operating/load voltage 6 Male 7 1 1 2 3 4 = n. c. = n. c. = n. c. = Tx – 5 6 7 8 = = = = Rx + Tx + n. c. Rx – 2 M12 x 1 connectors 4 5 3 Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim an der Ruhr • Phone 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Ethernet Compact fieldbus station FENP-S0008G 8 outputs 27 13 • 8 x 1 outputs (max. 0.5 A per output) • Common diagnostics • Status polling via integrated web server • Fully encapsulated plastic housing • Degree of protection IP67 13 C3 C2 C1 C0 O0 O1 O2 O3 1 0 9 8 7 2 3 4 5 6 AUX 4 5 6 ACT/LNK 8 7 2 3 MOD/NET 1 0 9 60,4 42 FENP-S0008G 1 0 9 2 3 8 7 4 5 6 O4 O5 220,5 O6 O7 C7 C6 C5 210,5 • General information: see page 68 5,4 C4 Type Ident-no. FENP-S0008G 6611041 Operating voltage U B Internal current consumption (via UB) 18...30 VDC < 150 mA Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (8) DC actuators 18...30 VDC 0.5 A per output, short-circuit protection < 250 Hz to bus 4 I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) UL UL < 18 VDC OS-7 output status: channel 7 (0 = OK, 1= fault) Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Input Output Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 UL OS-1 OS-0 Offset 0 – – – – – – – – – – – – – – Offset 1 – – – – – – – – OS-7 OS-6 OS-5 OS-4 OS-3 OS-2 – Offset 0 – – – – – – – – C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4 Wiring diagrams Outputs Ethernet DC actuator 5 PE 4 (+) BK 1 2 3 (–) BU M12 x 1 connectors Operating/load voltage Male Female 5 6 7 1 4 8 3 1 2 3 4 = n. c. = n. c. = n. c. = Tx – 5 6 7 8 = = = = Rx + Tx + n. c. Rx – 2 M12 x 1 connectors 4 5 3 Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 3 1 4 5 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim an der Ruhr • Phone 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 71 /0404 Ethernet Compact fieldbus station FENP-S0808G 8 inputs/8 outputs 27 13 • 4 x 2 inputs pnp 4 x 2 outputs (max. 0.5 A per output) • Common diagnostics • Status polling via integrated web server • Fully encapsulated plastic housing • Degree of protection IP67 13 C2 C3 C0 C1 I1 I0 I3 I2 I5 I4 I6 I7 1 0 9 8 7 2 3 4 5 6 4 5 6 AUX 2 3 8 7 ACT/LNK 1 0 9 60,4 42 FENP-S0808G 1 0 9 2 3 8 7 4 5 6 O9 220,5 O8 O11 O10 O13 O12 O15 O14 C6 C5 210,5 C7 5,4 • General information: see page 68 C4 Type Ident-no. FENP-S0808G 6611040 Operating voltage UB Internal current consumption (via UB) 18...30 VDC < 150 mA Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (8) pnp 3-wire sensors/2-wire sensors 18...30 VDC 500 mA per 8 inputs 2 mA / 4 mA 2.5 ms < 250 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (8) DC actuators 18...30 VDC 0.5 A per output, short-circuit protection < 250 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) UL UL < 18 VDC SC common short-circuit indication I > 500 mA OS-7 output status: channel 7 (0 = OK, 1= fault) Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Input Output Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Offset 0 – – – – – – – – Offset 1 – – – – – – – – – – – – – – Offset 2 – – – – – – – – OS-7 OS-6 OS-5 OS-4 OS-3 OS-2 Offset 0 – – – – – – – – C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 UL SC OS-1 OS-0 Wiring diagrams Inputs 3 wire pnp sensor 5 PE 4 BK 1 BN + 1 2 WH 2 ( ) WH 3 (–) BU 3 BU – M12 x 1 connectors 72 /0704 3 (–) BU 4 ( ) BK Operating/load voltage Female DC actuator 3 BU – 5 PE Bus line Outputs Output A 5 6 7 1 4 Output B 8 3 Male 1 2 3 4 = n. c. = n. c. = n. c. = Tx – 5 6 7 8 = = = = Rx + Tx + n. c. Rx – 2 M12 x 1 connectors 4 5 3 Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 1 3 4 5 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim an der Ruhr • Phone 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Ethernet Compact fieldbus station FENP-XSG16 16 inputs or outputs 27 13 • 16 configurable inputs, pnp or outputs (max. 0.5 A per output) • High flexibility through freely configurable inputs and outputs • Common diagnostics • Status polling via integrated web server • Fully encapsulated plastic housing • Degree of protection IP67 13 C3 C2 C1 C0 I/O0 I/O1 I/O2 I/O3 I/O4 I/O5 I/O6 I/O7 1 0 9 2 3 8 7 4 5 6 4 5 6 AUX 2 3 8 7 ACT/LNK 1 0 9 60,4 42 FENP-XSG16 1 0 9 2 3 8 7 4 5 6 I/O8 C6 C5 210,5 I/O9 I/O10 I/O11 I/O12 220,5 I/O13 I/O15 I/O14 C7 5,4 C4 • General information: see page 68 Type Ident-no. FENP-XSG16 6611042 Operating voltage U B Internal current consumption (via UB) 18...30 VDC < 100 mA Input circuits Input voltage (via UB) Input current Switching threshold OFF/ON Input time delay Switching frequency Potential isolation (16) pnp 3-wire sensors/2-wire sensors 18...30 VDC < 500 mA, short-circuit protection 2 mA / 4 mA 2.5 ms < 250 Hz to bus Output circuits Output voltage (via UL) Output current Switching frequency Potential isolation (16) DC actuators 18...30 VDC 0.5 A per output, short-circuit protection < 250 Hz to bus I/O data mapping Abbreviations: C1P4 connector 1, pin 4 (0 = OFF, 1 = ON) UL UL < 18 VDC SC common short-circuit indication I > 500 mA OS-7 output status: channel 7 (0 = OK, 1= fault) Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Input Offset 0 Offset 1 Output Bit 8 4 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 – – – – – – – – – – – – – – OS-8 OS-7 OS-6 OS-5 OS-4 OS-3 OS-2 UL SC OS-1 OS-0 Offset 2 OS-15 OS-14 OS-13 OS-12 OS-11 OS-10 OS-9 Offset 0 C7P2 C7P4 C6P2 C6P4 C5P2 C5P4 C4P2 C4P4 C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 Wiring diagrams Inputs 3 wire pnp sensor 5 PE 4 BK 3 (–) BU 4 ( ) BK 1 BN + 1 2 WH 2 ( ) WH 3 (–) BU 3 BU – M12 x 1 connectors Operating/load voltage Female DC actuator 3 BU – 5 PE Ethernet Outputs Output A 5 6 7 1 4 Output B 8 3 Male 1 2 3 4 = n. c. = n. c. = n. c. = Tx – 5 6 7 8 = = = = Rx + Tx + n. c. Rx – 2 M12 x 1 connectors 4 5 3 Female 2 1 1 2 3 4 5 = GND = GND = PE = UB = UL 2 3 1 4 5 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim an der Ruhr • Phone 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 73 /0404 PROFIBUS-DP Repeater REP-DP-0002 General information With the TURCK repeater REP-DP-0002 it is possible to construct two galvanically isolated PROFIBUS-DP segments. The number of RS485 components per segment is technically limited to a maximum of 32 nodes (incl. the repeater). If the repeaters are cascaded, up to 126 PROFIBUS-DP modules can be operated via a single master and the line length of a network can be increased. If a transmission error occurs, the faulty segment is automatically disconnected. If the error is resolved, communication is automatically resumed. A bus error in segment 2 is indicated by a red illuminated LED on the repeater. The TURCK repeater is specially suited for the high requirements of the harsh industrial environment. The bus in segment 2 can be dis- and reconnected electrically and mechanically during operation. Communcation in segment 1 is not affected by disconnection/re-connection. General technical data Adjustments Transmission rate – Automatic – Manual LED indications Function (Bus) Power (UB) Connections Power supply Segment 1 segment 1: (1) yellow: communication – OFF: no communication segment 2: (1) yellow: communication – red: bus error – OFF: no communication the flashing frequency of the “Function” LEDs is relative to the data volume in the respective bus segment (1) green: operational – green flashing: autobaud active (1) Power in: male 7/8" connector (1) Bus in: male M12 x 1 connector (1) Bus out: female connector M12 x 1 (2) Bus out: female connector M12 x 1 (1) Test out: female connector M12 x 1 NOTE: In order not to affect bus communiation, it is required that the measurement is effected earth-free, i.e. relative measurement between the signal lines A and B of a segment. Segment 2 Test socket Housing Material Mounting Degree of protection (IEC 60529/EN 60529) Operating temperature Dimensions 74 /0704 The transmission rate is adjusted via coded rotary switches: Pos. 0: Autobaud – 9.6 kBps up to 12 MBps Pos. 1: 9.6 kbps Pos. 2: 19.2 kbps Pos. 3: 45.45 kbps Pos. 4: 93.75 kbps Pos. 5: 187.5 kbps Pos. 6: 500 kbps Pos. 7: 1.5 Mbps Pos. 8: 3 Mbps Pos. 9: 6 Mbps Pos. A: 12 Mbps Positions B to F are not used. If the master sets a modified transmission rate, the autobaud search procedure can only be restarted after a voltage reset. PA6-GF30, glass-fibre reinforced plastic housing with encapsulated electronics and nickel-plated brass connectors via 3 through holes, Ø 5.4 mm IP67 (NEMA 1, 3, 4, 12, 13) 0 °C to +55 °C (+32 °F to +131 °F) 148 x 60 x 27 (H x W x D) Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com PROFIBUS-DP Repeater REP-DP-0002 27 • Enhances system availability • Tooling change capability • Segmentation and expansion of PROFIBUS-DP networks • Test socket for both segments • Direct earthing via earthing jumper • Manual and automatic adjustment of the transmission rate • Automatic disconnection of faulty segments • Automatic resumption of communication after error elimination 13 Power Segment 1 Out Function Out Function Segment 2 Segment 2 Power In Out 148 REP-DP 0002 Test 60,4 42 Segment 1 136 • General information: see page 74 Type Ident-no. REP-DP-0002 6825354 Operating voltage UB Internal current consumption (via UB) 18...30 VDC 62 mA at 30 VDC 100 mA at 18 VDC Bus termination according to the PROFIBUS guideline both PROFIBUS segments are to be independently terminated. Earthing/shielding The repeater can be grounded via the external screw. The shield of the bus line is capacitively coupled with the earthing screw. Additionally, the shield can be directly grounded via the earthing jumper. Repeater configuration 5 100 m (12 Mbit/s) Segment 1 Segment 1 Power Power Segment 1 Function Segment 1 Segment 2 Segment 2 Function Function REP-DP Segment 2 REP-DP Segment 2 Segment 1 Power Power Function Segment 2 RSS4.5-PDP-TR 100 m (12 Mbit/s) 100 m (12 Mbit/s) Segment 1 Power Segment 1 Segment 1 Segment 2 Segment 2 Power Function Function REP-DP Segment 2 100 m (12 Mbit/s) Wiring diagrams Bus1 ) Operating voltage Male 4 5 3 Test 1) Male 2 1 7/8" connectors 1 2 3 4 5 = = = = = GND GND – UB U L 2) 2 3 1 4 5 1 2 3 4 5 = = = = = 5 VDC A line GND B line shield Female Female 2 2 1 5 3 4 M12 x 1 connectors 1 5 3 4 1 2 3 4 5 = = = = = B line Seg.1 A line Seg.1 B line Seg.2 A line Seg.2 shield M12 x 1 connectors 1 ) Reverse-keyed acc. to PROFIBUS guidelines 2) For feed-through of UL to other bus devices Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 75 /0704 CAN (DeviceNet™) Repeater REP-DN General information The REP-DN can be operated in any kind of "Controller Area“ network (CAN), including DeviceNet™. Network segments, which are directly interconnected via a repeater, are seen as physically separate networks, but as a logical unit. The networks are "physically separated“, because the trunk line and drop line lengths are determined independently of the other segment. The networks must be regarded as a logical unit, because the addresses cannot be duplicated - the scanner and configuration tools operate as a network. The repeater does not require an address and is thus not detected by the other devices within the network. The repeater also does not need an EDS file. The REP-DN is designed to extend the length of trunk or drop lines. A further application is the separation of power supply modules in networks operating with multiple power supplies. The number or repeaters within a network is not limited. The repeater automatically detects the transmission speed. General technical data Adjustments Transmission rate LED indications Connections Bus line yellow: detection of the transmission rate green flashing: ready for data repetition green: data repetition red: data repetition not possible 5-pole 7/8” connector Housing Mounting Degree of protection (IEC 60529/EN 60529) Operating temperature Dimensions 76 /0704 125 kbps, 250 kbps, 500 kbps or autobaud setting via rotary switches PA6-GF30, glass-fibre reinforced plastic housing with encapsulated electronics and nickel-plated brass connectors (4) through-holes, Ø 5.3 mm IP67 (NEMA 1, 3, 4, 12, 13) -25 °C to +70 °C (-13 °F to +158 °F) 220 x 60 x 40.3 (H x W x D) Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com CAN (DeviceNet™) Repeater REP-DN 40,3 27 13 Node Address (00-63, PGM) Data Rate (Kb) 500 AUTO 2 3 2 3 4 1 250 1 4 0 5 0 125 5 6 9 6 PGM 8 7 PGM MSD LSD 60,4 13 • Glass-fibre reinforced plastic housing • Fully encapsulated module electronics • Degree of protection IP67 • Extremely robust • Extension of the max. trunk line length • Extension of the max. drop line length • Isolation of the DeviceNet™ power supply 42 5,4 210,5 220,5 • General information: see page 76 Type Ident-no. REP-DN 6825349 Operating voltage UB Bus voltage Current consumption 11…30 VDC 125 mA segment A, 30 mA segment B Repeater configuration Extension of the trunk line In order to extend the trunk line, the repeaters are connected in series. The total delay time of the network accords to the sum of the delay times of the individual repeaters. The total delay time is thus 2 ms multiplied by the number of repeaters. Extension of the drop line In order to extend the drop line, the repeaters are connected in parallel. The total delay time accords to 2 ms because there is always only one repeater between the scanner on the trunk line and the other device. Segment B 500 m (125 k) Segment B 500 m (125 k) RSM57-TR2 A ring structure is not admissible Even though repeaters are used to construct large and complex networks, some configurations are not permitted. If a ring is created (both sides of the repeater are connected to the same network), then the repeater will constantly repeat itself, thus causing a network overload. Segment B 500 m (125 k) RSM57-TR2 RSM57-TR2 Node Address (00-63, PGM) Data Rate (Kb) 500 AUTO 2 3 2 3 1 4 250 4 1 0 5 0 125 5 6 6 9 PGM 8 7 PGM MSD LSD RSM57-TR2 Node Address (00-63, PGM) Data Rate (Kb) 500 AUTO 2 3 2 3 4 1 250 4 1 0 5 0 125 5 6 9 6 PGM 8 7 PGM MSD LSD Segment A 500 m (125 k) Node Address (00-63, PGM) Data Rate (Kb) 500 AUTO 2 3 2 3 4 1 250 4 1 0 5 0 125 5 6 9 6 PGM 8 7 PGM MSD LSD Segment A 500 m (125 k) Wiring diagrams Operating voltage/bus line Male 4 5 3 Female 2 1 1 2 3 4 5 = = = = = shield V+ V– CAN_H CAN_L 2 1 3 4 5 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 77 /0704 5 CAN (DeviceNet™) Spanner module FDN-DN1 General information The FDN-DN1 spanner module is designed for data transmission between two DeviceNet™ controllers. The module eliminates the need for a higher level network pyramid because the DeviceNet™ networks can be coupled directly with each other. The concept is simple, efficient and cost-effective. Simple - because the spanner module's data are processed like those of a standard I/O module by the controller. Additionally each DeviceNet™ scanner can transfer I/O data to the module without requiring any additional software or complex configuration procedures. General technical data Adjustments Address A Address B Transmission volume (via rotary switch) Transmission volume (via software) LED indications Connections Bus line Efficient - because the spanner module is capable of transferring up to 128 data bytes per message. Cost-effective - because a higher level control network, two separate control cards, wiring, routing and programming are superfluous. The spanner module must basically be seen as two DeviceNet™ devices, i. e. one in network A and the other in network B, so that it is equipped with two addressing switches. These are completely independent of each other. During start-up the module automatically detects the transmission rate. Networks A and B can be operated with different transmission rates. 0...63 via rotary switch 0...63 via rotary switch 4,16, 32 or 128 bytes 0...128 bytes – in case of software configuration, the bi-directional data volume must not be identical. yellow: detection of the transmission rate green flashing: device is on-line, but not logically connected to the master green: device is logically connected to the master and functions correctly red flashing: I/O connection time-out red: communication not possible 5-pin 7/8” connector Housing Mounting Degree of protection (IEC 60529/EN 60529) Operating temperature Dimensions PA6-GF30, glass-fibre reinforced plastic housing with encapsulated electronics and nickel-plated brass connectors (4) through-holes, Ø 5.3 mm IP67 (NEMA 1, 3, 4, 12, 13) -25 °C to +70 °C (-13 °F to +158 °F) 220 x 60 x 40.3 (H x W x D) Approvals UL, CSA 78 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com CAN (DeviceNet™) Spanner module FDN-DN1 40,3 27 13 Node Address (00-63, PGM) Data Rate (Kb) 500 AUTO 2 3 2 3 4 1 250 1 4 0 5 0 125 5 6 9 6 PGM 8 7 PGM MSD LSD 60,4 13 • For bi-directional data transfer between two controllers • Transmission of up to 128 data bytes between two controllers • Galvanic isolation of two networks via opto-couplers • Addressing rotary switch 42 • General information: see page 78 5,4 210,5 220,5 Type Ident-no. EDS file FDN-DN1 6603596 F0132/I032_xx.eds (downloadable via the internet under www.turck.com) Operating voltage UB Bus voltage Current consumption 11...30 VDC 125 mA segment A, 30 mA segment B 5 Spanner module topology PLC conveyor network The spanner module is mainly used to coordinate multiple work cells. to other stations on conveyor Node Address (00-63, PGM) Data Rate (Kb) 500 AUTO 2 3 2 3 4 1 250 1 4 0 5 0 125 5 6 6 9 PGM 8 7 PGM MSD LSD Node Address (00-63, PGM) Data Rate (Kb) 500 AUTO 2 3 2 3 4 1 250 1 4 0 5 0 125 5 6 6 9 PGM 8 7 PGM MSD LSD further stations further stations PLC work cell A PLC work cell B Wiring diagrams Operating voltage/bus line Male 4 5 3 Female 2 1 1 2 3 4 5 = = = = = shield V+ V– CAN_H CAN_L 2 1 3 4 5 7/8" connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 79 /0704 Ethernet Unmanaged switches General information The high performance industrial Ethernet™ switches provide five or nine M12 x 1 ports. The switch complies with IEEE 802.3 10Base-T Ethernet and 802.3u100Base-TX Fast Ethernet™ standards. The switch auto-senses transmission speeds of 10 or 100 Mbps. It stores the addresses in its routing table. The switch supports "store-and-forward“ switching architecture. The Ethernet™ switch is suited for the following applications: • Segmentation of network traffic • Expansion of the Ethernet™ network length • Conversion of data packets between different transmission speeds General technical data LED indications Power Act/Link 10/100 green: operational, OFF: operating voltage not applied green: port linked, green flashing: port active 10/100 Mbps green: 100 Mbps / OFF: 10 Mbps Connections Ethernet Power supply nickel-plated brass connectors M12 x 1 connectors 7/8" connector, 5-pole Housing PA6-GF30, glass-fibre reinforced plastic housing with encapsulated electronics and nickel-plated brass connectors Mounting Degree of protection Temperature range Dimensions – SE-84X-E924 – SE-84X-E524 via 4 through-holes, Ø 5.4 mm NEMA 1, 3, 4, 12, 13 and IEC IP67 -40 °C to +85 °C (-40 °F to +185 °F) 80 /0704 105 x 200 x 30 (H x W x D) 95 x 160 x 30 (H x W x D) Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Ethernet Unmanaged switches SE-84X-E524 (5 ports) • 10/100 Mbps ports: 4 ports plus 1 uplink port • Standards: IEEE 802.3, 802.3u, 802.3x • Switching architecture: "Store-andForward" • Buffer: 128 bytes • Nway Auto-Negotiation: all ports • Full Duplex/Half Duplex: all ports • "Non-blocking“ Full Duplex Mode (no collision) • Memory bandwidth: 1.4 Gbps • Degree of protection IP67 Power SE-84X-E524 5-Port Industrial Ethernet Switch LED OFF ON 10/100 10 Mbits 100 Mbits ------ Act/Link No Link Linked Activity -- Power Port Blink 4 5 3 2 1 10-30 VDC 10/100 Act/Link 10/100 Act/Link 10/100 Act/Link 10/100 Act/Link 1 = N/C 2 = (- Voltage) 3 = N/C 4 = (+ Voltage) 5 = N/C 10/100 Act/Link 68 95 Uplink Port 143 160 • General information: see page 80 Type Ident-no. SE-84X-E524 6607000 Operating voltage UB Internal power consumption 10...30 VDC 1.9 W (typical) 5 Wiring diagrams Ethernet Operating voltage Male 4 5 3 2 1 7/8" connectors 1 2 3 4 5 = n. c. = – voltage = n. c. = + voltage = n. c. Female 5 6 7 1 4 8 3 2 Uplink port 1 = n. c. 2 = n. c. 3 = n. c. 4 = Tx – 5 6 7 8 = = = = Rx + Tx + n. c. Rx – Downlink port 1 = n. c. 5 = Tx + 2 = n. c. 6 = Rx + 3 = n. c. 7 = n. c. 4 = Rx – 8 = Tx – M12 x 1 connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 81 /0704 Ethernet Unmanaged switches SE-84X-E924 (9 ports) • 10/100 Mbps ports: 8 ports plus 1 uplink port • Standards: IEEE 802.3, 802.3u, 802.3x • Switching architecture: "Store-andForward" • Buffer: 128 bytes • Nway Auto-Negotiation: all ports • Full Duplex/Half Duplex: all ports • "Non-blocking“ Full Duplex Mode (no collision) • Memory bandwidth: 1.4 Gbps • Protection degree IP67 Power SE-84X-E924 9-Port Industrial Ethernet Switch LED OFF ON 10/100 10 Mbits 100 Mbits ------ Act/Link No Link Linked Activity -- Power Port Blink 3 4 5 2 1 10-30 VDC 10/100 Act/Link Uplink Port 10/100 Act/Link 10/100 Act/Link 10/100 Act/Link 10/100 Act/Link 10/100 Act/Link 1 = N/C 2 = (- Voltage) 3 = N/C 4 = (+ Voltage) 5 = N/C 10/100 Act/Link 10/100 Act/Link 78 105 10/100 Act/Link 182 200 • General information: see page 80 Type Ident-no. SE-84X-E924 6607001 Operating voltage UB Current consumption 10...30 VDC 4 W (typical) Wiring diagrams Ethernet Operating voltage Male 4 5 3 2 1 7/8" connectors 82 /0704 1 2 3 4 5 = n. c. = – voltage = n. c. = + voltage = n. c. Female 5 6 7 1 4 8 3 2 Uplink port 1 = n. c. 2 = n. c. 3 = n. c. 4 = Tx – 5 6 7 8 = = = = Rx + Tx + n. c. Rx – Downlink port 1 = n. c. 5 = Tx + 2 = n. c. 6 = Rx + 3 = n. c. 7 = n. c. 4 = Rx – 8 = Tx – M12 x 1 connectors Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 5 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com 83 /0704 Buskabel-Qualitäten PROFIBUS-DP, CAN (DeviceNet™, CANopen), Ethernet (vorkonfektionierte Leitungen ab Seite A1 – 4) Bus Cable Materials PROFIBUS-DP, CAN (DeviceNet™, CANopen), Ethernet (premoulded Cables from page A1 – 4 onwards) Feldbus Kabeltyp Abb. Fieldbus Cable type Fig. Material Kabelmantel Material cable jacket Halogenfrei Halogen-free Schleppkettenfähig Suited to trailing applications Data pair Leiter-Querschnitt Connection profile Nennstrom Rated current DC-Widerstand DC resistance [mm2] [A] [Ω/km] PROFIBUS-DP 451 (A) TPUS • • 2 x 0,34 4 50 CAN (DeviceNet™, CANopen) 572 (Thin) (B) PVC – – 2 x 0,32 6,4 54,1 CAN (DeviceNet™, CANopen) 5711 (Mid) (C) PVC – – 2 x 0,52 9,6 34,1 CAN (DeviceNet™, CANopen) 5723 (Mid) (C) PUR – • 2 x 0,52 9,6 34,1 Ethernet 841 (D) PVC – • 8 x 0,21 1,5 94 Ethernet 843 (D) PVC – – 8 x 0,21 1,5 94 Versorgungskabel-Qualitäten PROFIBUS-DP, CAN (DeviceNet™, CANopen) (vorkonfektionierte Leitungen ab Seite A2 – 2) Power Cable Materials PROFIBUS-DP, CAN (DeviceNet™, CANopen) (premoulded cables from page A2 – 2 onwards) Nutzbar für Gerätefamilie (Bussystem) Usable for product family (Bus System) Bussystem Kabeltyp Abb. Bus System Cable type Fig. Material Kabelmantel Material cable jacket Halogenfrei Schleppkettenfähig Leiter-Querschnitt Halogen-free Suited to trailing applications Connection profile [mm2] 52 (E) PUR • • 5 x 1,5 DeviceNet™ 43 (F) PUR • • 4 x 1,5 PROFIBUS-DP, CAN IPS (G) PUR – • 4 x 0,34 BL67 PROFIBUS-DP, CAN FLDP, PDP, FXDP PROFIBUS-DP FENP Ethernet™ FDN... piconet® (A) (B) (C) (D) WH BU A1 – 2 /0704 7,24 mm GN GNWH BU BUWH BN BNWH BK 8,5mm OG OGWH 8,38 mm RD 7,3 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Power pair Nennwerte Leiter-Querschnitt Connection profile Nennstrom Rated current DC-Widerstand DC resistance [mm2] [A] [Ω/km] – – – 2 x 0,32 6,4 2 x 1,30 2 x 1,04 Nom. Impedanz Data pair nom. impedance Data pair Ratings Schirmung Nom. Kapazität Data pair Shield nom. capacitance Data pair Zulassungen ab Seite ... Approvals from page ... onwards [Ω] [pF/m] 300 V, 80 °C 150 (3...20 MHz) 30 • – A1 – 4 54,1 300 V, 80 °C 126 (1MHz) 37,17 • UL, CSA A1 – 8 15,2 13,5 300 V, 80 °C 110 (1 MHz) 40,52 • UL, CSA A1 – 10 13,6 16,9 300 V, 80 °C 110 (1 MHz) 40,52 • UL, CSA A1 – 12 – – – 300 V, 75 °C 100 (1 MHz) 46 • UL A1 – 16 – – – 300 V, 75 °C 100 (1 MHz) 46 • UL A1 – 16 Nennstrom DC-Widerstand Nennwerte Nom. Impedanz Nom. Kapazität Schirmung Zulassungen ab Seite ... Rated current DC resistance Ratings nom. impedance nom. capacitance Shield Approvals from page ... onwards [A] [Ω/km] [Ω] [pF/m] 15 13,3 240 V, 90 °C – – – – A2 – 2 15 13,3 240 V, 90 °C – – – – A2 – 4 6 58,7 240 V, 80 °C – – – – A2 – 6 (E) (F) BN RD WH BU GNYE (G) GN BK WH WH BK BN BU BK 8,5 7,5 7,5 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A1 – 3 /0704 A1 Vorkonfektionierte Buskabel für PROFIBUS-DP, Typ 451 Premoulded Bus Cables for PROFIBUS-DP, Type 451 Konfektionierbare Steckverbinder siehe Seite A3 – 4 Field wireable connectors see page A3 – 4 Abmessungen/Bauform Anschluss Dimensions/Housing style Connection Steckverbinderausführung/ Maßbild Connector type/ dimension drawing [mm] Kabel-Meterware p – 30 Bulk cable p – 150 p – 500 ø 14,2 2 M12 x 1 w 18,2 3 1 4 (A) 1= 2= 3= 4= 5= 5 n. c. GN (Bus_A) n. c. RD (Bus_B) shield 2 M12 x 1 ø 14,2 M12 x 1 v 11,5 48,5 1 5 3 4 (B) 2 43,5 36,0 M12 x 1 40,1 3 w M12 x 1 ø 14,2 (C) 1 4 1= 2= 3= 4= 5= 43,5 36,0 M12 x 1 v n. c. GN (Bus_A) n. c. RD (Bus_B) shield 1 5 M12 x 1 ø 14,2 (D) A1 – 4 /0704 3 4 w o (A) 6 w o (A) 10 w o (A) 15 v o (B) 6 v o (B) 10 v o (B) 15 w v (A) + (B) 0,3 w v (A) + (B) 0,5 w v (A) + (B) 1 w v (A) + (B) 2 w v (A) + (B) 4 w v (A) + (B) 6 w v (A) + (B) 10 w v (A) + (B) 15 w v (A) + (B) 30 w o (C) 6 w o (C) 10 w o (C) 15 v o (D) 6 v o (D) 10 v o (D) 15 w v (C) + (D) 0,3 w v (C) + (D) 0,5 w v (C) + (D) 1 w v (C) + (D) 2 w v (C) + (D) 4 w v (C) + (D) 6 w v (C) + (D) 10 w v (C) + (D) 15 w v (C) + (D) 30 5 2 32,0 Cable length [m] M12 x 1 55,2 Kabellänge Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typenbezeichnung Ident-Nr. Kabeltyp Material Kabelmantel Material cable jacket Invers codiert gemäß PNO-Richtlinie Reverse keyed acc. to PNO guidelines Schleppkettenfähig Schutzart Type Ident No. Cable type Suited to trailing applications Degree of protection KABEL451-30M 6915601 KABEL451-150M 6915603 451 TPUS – • – 451 TPUS – • KABEL451-500M – 6915606 451 TPUS – • – RSSW451-6M 6914111 451 TPUS • • IP67 RSSW451-10M 6914112 451 TPUS • • IP67 RSSW451-15M 6914113 451 TPUS • • IP67 RKSW451-6M 6914114 451 TPUS • • IP67 RKSW451-10M 6914115 451 TPUS • • IP67 RKSW451-15M 6914116 451 TPUS • • IP67 RSSW-RKSW451-0,3M 6915655 451 TPUS • • IP67 RSSW-RKSW451-0,5M 6914117 451 TPUS • • IP67 RSSW-RKSW451-1M 6914118 451 TPUS • • IP67 RSSW-RKSW451-2M 6914119 451 TPUS • • IP67 RSSW-RKSW451-4M 6914120 451 TPUS • • IP67 RSSW-RKSW451-6M 6914121 451 TPUS • • IP67 RSSW-RKSW451-10M 6914122 451 TPUS • • IP67 RSSW-RKSW451-15M 6914123 451 TPUS • • IP67 RSSW-RKSW451-30M 6914124 451 TPUS • • IP67 WSSW451-6M 6914128 451 TPUS • • IP67 WSSW451-10M 6914129 451 TPUS • • IP67 WSSW451-15M 6914130 451 TPUS • • IP67 WKSW451-6M 6914131 451 TPUS • • IP67 WKSW451-10M 6914132 451 TPUS • • IP67 WKSW451-15M 6914133 451 TPUS • • IP67 WSSW-WKSW451-0,3M 6915680 451 TPUS • • IP67 WSSW-WKSW451-0,5M 6914134 451 TPUS • • IP67 WSSW-WKSW451-1M 6914135 451 TPUS • • IP67 WSSW-WKSW451-2M 6914136 451 TPUS • • IP67 WSSW-WKSW451-4M 6914137 451 TPUS • • IP67 WSSW-WKSW451-6M 6914138 451 TPUS • • IP67 WSSW-WKSW451-10M 6914139 451 TPUS • • IP67 WSSW-WKSW451-15M 6914140 451 TPUS • • IP67 WSSW-WKSW451-30M 6914141 451 TPUS • • IP67 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A1 – 5 /0704 A1 Vorkonfektionierte Buskabel für PROFIBUS-DP, Typ 451 Premoulded Bus Cables for PROFIBUS-DP, Type 451 Konfektionierbare Steckverbinder siehe Seite A3 – 4 Field wireable connectors see page A3 – 4 Abmessungen/Bauform Anschluss Abschlusswiderstand Kabellänge Dimensions/Housing style Connection Terminating resistor Cable length [mm] 1 = n.c. 2 = n.c. 3 = RD 4 = n.c. 5 = n.c. 6 = n.c. 7 = n.c. 8 = GN 9 = n.c. 12345 [m] (Bus_B) w o – 2 x 0,5 w o – 2x1 w o – 2x2 ww v – 2 x 0,3 ww v – 2 x 0,5 ww v – 2x1 ww v – 2x2 vw v – 2 x 0,3 vw v – 2 x 0,5 vw v – 2x1 vw v – 2x2 w o • 0,5 w o • 1 w o • 2 w w • 0,3 w w • 0,5 w w • 1 w w • 2 v w • 0,3 v w • 0,5 v w • 1 v w • 2 (Bus_A) 6789 2 3 M12 x 1 1 4 w 5 2 1 5 M12 x 1 3 v 4 2 1 5 M12 x 1 3 v 4 2 1 5 M12 x 1 3 v 4 390 W 1 110 nH 2 3 4 4 5 1 220 W 6 7 8 9 2 3 5 390 W 110 nH 2 3 1 4 5 w 5 2 1 M12 x 1 M12 x 1 3 4 A1 – 6 /0704 v Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typenbezeichnung Ident-Nr. Kabeltyp Type Ident No. Cable type Material Kabelmantel Material cable jacket Invers codiert gemäß PNO-Richtlinie Reverse keyed acc. to PNO guidelines Schleppkettenfähig Schutzart Suited to trailing applications Degree of protection SUB-D / M12 D9-451-0,5M-0,5M 6915747 451 TPUS • • IP20 / – D9-451-1M-1M 6915748 451 TPUS • • IP20 / – D9-451-2M-2M 6915749 451 TPUS • • IP20 / – RSSW-D9-RKSW-451-0,3M-0,3M 6914125 451 TPUS • • IP20 / IP67 RSSW-D9-RKSW-451-0,5M-0,5M 6915741 451 TPUS • • IP20 / IP67 RSSW-D9-RKSW-451-1M-1M 6914126 451 TPUS • • IP20 / IP67 RSSW-D9-RKSW-451-2M-2M 6914127 451 TPUS • • IP20 / IP67 RKSW-D9-RKSW-451-0,3M-0,3M 6604659 451 TPUS • • IP20 / IP67 RKSW-D9-RKSW-451-0,5M-0,5M 6915792 451 TPUS • • IP20 / IP67 RKSW-D9-RKSW-451-1M-1M 6915793 451 TPUS • • IP20 / IP67 RKSW-D9-RKSW-451-2M-2M 6915794 451 TPUS • • IP20 / IP67 D9T451-0,5M 6915757 451 TPUS • • IP20 / – D9T451-1M 6915758 451 TPUS • • IP20 / – D9T451-2M 6915759 451 TPUS • • IP20 / – RSSW-D9T451-0,3M 6915775 451 TPUS • • IP20 / IP67 RSSW-D9T451-0,5M 6915777 451 TPUS • • IP20 / IP67 RSSW-D9T451-1M 6915778 451 TPUS • • IP20 / IP67 RSSW-D9T451-2M 6915779 451 TPUS • • IP20 / IP67 RKSW-D9T451-0,3M 6915765 451 TPUS • • IP20 / IP67 RKSW-D9T451-0,5M 6915767 451 TPUS • • IP20 / IP67 RKSW-D9T451-1M 6915768 451 TPUS • • IP20 / IP67 RKSW-D9T451-2M 6915769 451 TPUS • • IP20 / IP67 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A1 – 7 /0704 A1 Vorkonfektionierte Buskabel für CAN (DeviceNet™, CANopen), Typ 572 Premoulded Bus Cables for CAN (DeviceNet™, CANopen), Type 572 Konfektionierbare Steckverbinder siehe Seite A3 – 12 Field wireable connectors see page A3 – 12 Abmessungen/Bauform Anschluss Dimensions/Housing style Connection Steckverbinderausführung/ Maßbild Connector type/ dimension drawing [mm] [m] p – 30 Bulk cable p – 150 p – 500 ø 14,2 2 M12 x 1 w 1 3 18,2 4 (A) 1 = shield 2 = RD 3 = BK 4 = WH 5 = BU M12 x 1 ø 14,2 (V +) (V –) (CAN_H) (CAN_L) 2 M12 x 1 v 5 3 1 11,5 48,5 5 4 (B) 43,5 36,0 2 M12 x 1 40,1 w 1 3 4 1 = shield 2 = RD 3 = BK 4 = WH 5 = BU (C) 43,5 36,0 v (D) A1 – 8 /0704 3 1 5 M12 x 1 ø 14,2 (V +) (V –) (CAN_H) (CAN_L) 2 M12 x 1 4 w o (A) 6 w o (A) 10 w o (A) 15 v o (B) 6 v o (B) 10 v o (B) 15 w v (A) + (B) 0,3 w v (A) + (B) 0,5 w v (A) + (B) 1 w v (A) + (B) 2 w v (A) + (B) 4 w v (A) + (B) 6 w v (A) + (B) 10 w v (A) + (B) 15 w v (A) + (B) 30 w o (C) 6 w o (C) 10 w o (C) 15 v o (D) 6 v o (D) 10 v o (D) 15 w v (C) + (D) 0,3 w v (C) + (D) 0,5 w v (C) + (D) 1 w v (C) + (D) 2 w v (C) + (D) 4 w v (C) + (D) 6 w v (C) + (D) 10 w v (C) + (D) 15 w v (C) + (D) 30 5 M12 x 1 ø 14,2 32,0 Cable length Kabel-Meterware M12 x 1 55,2 Kabellänge Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typenbezeichnung Ident-Nr. Kabeltyp Type Ident No. Cable type KABEL572-30M 6958118 572 KABEL572-150M 6958120 572 KABEL572-500M 6604900 RSC572-6M RSC572-10M Material Kabelmantel Material cable jacket Schleppkettenfähig Schutzart Suited to trailing applications Degree of protection PVC – – PVC – – 572 PVC – – 6602447 572 PVC – IP67 6602640 572 PVC – IP67 RSC572-15M 6603623 572 PVC – IP67 RKC572-6M 6603624 572 PVC – IP67 RKC572-10M 6602428 572 PVC – IP67 RKC572-15M 6604933 572 PVC – IP67 RSC-RKC572-0.3M 6602473 572 PVC – IP67 RSC-RKC572-0.5M 6602332 572 PVC – IP67 RSC-RKC572-1M 6603628 572 PVC – IP67 RSC-RKC572-2M 6603629 572 PVC – IP67 RSC-RKC572-4M 6603630 572 PVC – IP67 RSC-RKC572-6M 6602394 572 PVC – IP67 RSC-RKC572-10M 6602639 572 PVC – IP67 RSC-RKC572-15M 6602635 572 PVC – IP67 RSC-RKC572-30M 6603395 572 PVC – IP67 WSC572-6M 6603635 572 PVC – IP67 WSC572-10M 6603636 572 PVC – IP67 WSC572-15M 6603637 572 PVC – IP67 WKC572- 6M 6603638 572 PVC – IP67 WKC572-10M 6602637 572 PVC – IP67 WKC572-15M 6603640 572 PVC – IP67 WSC-WKC572- 0.3M 6603608 572 PVC – IP67 WSC-WKC572- 0.5M 6602024 572 PVC – IP67 WSC-WKC572-1M 6602027 572 PVC – IP67 WSC-WKC572-2M 6602030 572 PVC – IP67 WSC-WKC572-4M 6602542 572 PVC – IP67 WSC-WKC572-6M 6603645 572 PVC – IP67 WSC-WKC572-10M 6602638 572 PVC – IP67 WSC-WKC572-15M 6602684 572 PVC – IP67 WSC-WKC572-30M 6603648 572 PVC – IP67 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A1 – 9 /0704 A1 Vorkonfektionierte Buskabel für CAN (DeviceNet™, CANopen), Typ 5711 Premoulded Bus Cables for CAN (DeviceNet™, CANopen), Type 5711 Konfektionierbare Steckverbinder siehe Seite A3 – 12 Field wireable connectors see page A3 – 12 Abmessungen/Bauform Anschluss Dimensions/Housing style Connection Steckverbinderausführung/ Maßbild Connector type/ dimension drawing [mm] ø 20,5 ø 7,3 p – 30 p – 150 p – 500 7/8“ w 36,0 7/8-16UN ø 17,5 ø 27,0 65,0 3 4 5 7/8“ v 2 2 1 1 = shield 2 = RD 3 = BK 4 = WH 5 = BU (A) ø 20,5 ø 7,3 [m] Bulk cable ø 27,0 68,5 (V +) (V –) (CAN_H) (CAN_L) 3 1 4 5 29,0 (B) ø 7,3 51,25 41,0 7/8“ ø 17,5 43,5 34,0 w 7/8-16UN ø 26,0 51,25 41,0 ø 17,5 40,0 30,55 7/8-16UN ø 26,0 (D) A1 – 10 /0704 3 4 5 7/8“ v 2 1 2 1 1 = shield 2 = RD 3 = BK 4 = WH 5 = BU (C) ø 7,3 Cable length Kabel-Meterware 7/8-16UN ø 17,5 Kabellänge (V +) (V –) (CAN_H) (CAN_L) 3 4 5 w o (A) 6 w o (A) 10 w o (A) 15 v o (B) 6 v o (B) 10 v o (B) 15 w v (A) + (B) 0,3 w v (A) + (B) 0,5 w v (A) + (B) 1 w v (A) + (B) 2 w v (A) + (B) 4 w v (A) + (B) 6 w v (A) + (B) 10 w v (A) + (B) 15 w v (A) + (B) 30 w o (C) 6 w o (C) 10 w o (C) 15 v o (D) 6 v o (D) 10 v o (D) 15 w v (C) + (D) 0,3 w v (C) + (D) 0,5 w v (C) + (D) 1 w v (C) + (D) 2 w v (C) + (D) 4 w v (C) + (D) 6 w v (C) + (D) 10 w v (C) + (D) 15 w v (C) + (D) 30 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typenbezeichnung Ident-Nr. Kabeltyp Type Ident No. Cable type KABEL5711-30M 6602453 5711 KABEL5711-150M 6602455 5711 KABEL5711-500M 6604922 RSM5711-6M RSM5711-10M Material Kabelmantel Material cable jacket Schleppkettenfähig Schutzart Suited to trailing applications Degree of protection PVC – – PVC – – 5711 PVC – – 6603649 5711 PVC – IP67 6603650 5711 PVC – IP67 RSM5711-15M 6603651 5711 PVC – IP67 RKM5711-6M 6603652 5711 PVC – IP67 RKM5711-10M 6603653 5711 PVC – IP67 RKM5711-15M 6602395 5711 PVC – IP67 RSM-RKM5711- 0.3M 6602611 5711 PVC – IP67 RSM-RKM5711- 0.5M 6602050 5711 PVC – IP67 RSM-RKM5711- 1M 6602356 5711 PVC – IP67 RSM-RKM5711- 2M 6602045 5711 PVC – IP67 RSM-RKM5711- 4M 6602051 5711 PVC – IP67 RSM-RKM5711- 6M 6602052 5711 PVC – IP67 RSM-RKM5711-10M 6602023 5711 PVC – IP67 RSM-RKM5711-15M 6602504 5711 PVC – IP67 RSM-RKM5711-30M 6603662 5711 PVC – IP67 WSM5711- 6M 6606039 5711 PVC – IP67 WSM5711-10M 6602718 5711 PVC – IP67 WSM5711-15M 6603225 5711 PVC – IP67 WKM5711- 6M 6605296 5711 PVC – IP67 WKM5711- 10M 6605298 5711 PVC – P67 WKM5711- 15M 6605299 5711 PVC – IP67 WSM-WKM5711- 0.3M 6605652 5711 PVC – IP67 WSM-WKM5711- 0.5M 6602014 5711 PVC – IP67 WSM-WKM5711- 1M 6602016 5711 PVC – IP67 WSM-WKM5711- 2M 6602018 5711 PVC – IP67 WSM-WKM5711- 4M 6605654 5711 PVC – IP67 WSM-WKM5711- 6M 6602401 5711 PVC – IP67 WSM-WKM5711-10M 6602022 5711 PVC – IP67 WSM-WKM5711-15M 6603447 5711 PVC – IP67 WSM-WKM5711-30M 6605657 5711 PVC – IP67 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A1 A1 – 11 /0704 Vorkonfektionierte Buskabel für CAN (DeviceNet™, CANopen), Typ 5723 Premoulded Bus Cables for CAN (DeviceNet™, CANopen), Type 5723 Konfektionierbare Steckverbinder siehe Seite A3 – 12 Field wireable connectors see page A3 – 12 Abmessungen/Bauform Anschluss Dimensions/Housing style Connection Steckverbinderausführung/ Maßbild Connector type/ dimension drawing [mm] ø 20,5 ø 7,3 p – 30 p – 150 p – 500 7/8“ w 36,0 7/8-16UN ø 17,5 ø 27,0 65,0 3 4 5 7/8“ v 2 2 1 1 = shield 2 = RD 3 = BK 4 = WH 5 = BU (A) ø 20,5 ø 7,3 [m] Bulk cable ø 27,0 68,5 (V +) (V –) (CAN_H) (CAN_L) 3 1 4 5 29,0 (B) ø 7,3 51,25 41,0 7/8“ ø 17,5 43,5 34,0 w 7/8-16UN ø 26,0 51,25 41,0 40,0 30,55 7/8-16UN ø 26,0 (D) A1 – 12 /0704 5 2 ø 17,5 3 4 7/8“ v 1 2 1 1 = shield 2 = RD 3 = BK 4 = WH 5 = BU (C) ø 7,3 Cable length Kabel-Meterware 7/8-16UN ø 17,5 Kabellänge (V +) (V –) (CAN_H) (CAN_L) 3 w o (A) 6 w o (A) 10 w o (A) 15 v o (B) 6 v o (B) 10 v o (B) 15 w v (A) + (B) 0,3 w v (A) + (B) 0,5 w v (A) + (B) 1 w v (A) + (B) 2 w v (A) + (B) 4 w v (A) + (B) 6 w v (A) + (B) 10 w v (A) + (B) 15 w v (A) + (B) 30 w o (C) 6 w o (C) 10 w o (C) 15 v o (D) 6 v o (D) 10 v o (D) 15 w v (C) + (D) 0,3 4 w v (C) + (D) 0,5 5 w v (C) + (D) 1 w v (C) + (D) 2 w v (C) + (D) 4 w v (C) + (D) 6 w v (C) + (D) 10 w v (C) + (D) 15 w v (C) + (D) 30 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typenbezeichnung Ident-Nr. Kabeltyp Type Ident No. Cable type KABEL5723-30M 6604923 5723 KABEL5723-150M 6604925 5723 KABEL5723-500M 6604928 RSM5723-6M RSM5723-10M Material Kabelmantel Material cable jacket Schleppkettenfähig Schutzart Suited to trailing applications Degree of protection PUR • – PUR • – 5723 PUR • – 6605933 5723 PUR • IP67 6605935 5723 PUR • IP67 RSM5723-15M 6605936 5723 PUR • IP67 RKM5723-6M 6605189 5723 PUR • IP67 RKM5723-10M 6605191 5723 PUR • IP67 RKM5723-15M 6605192 5723 PUR • IP67 RSM-RKM5723-0.3M 6605544 5723 PUR • IP67 RSM-RKM5723-0.5M 6605545 5723 PUR • IP67 RSM-RKM5723-1M 6605546 5723 PUR • IP67 RSM-RKM5723-2M 6605548 5723 PUR • IP67 RSM-RKM5723-4M 6605551 5723 PUR • IP67 RSM-RKM5723-6M 6605553 5723 PUR • IP67 RSM-RKM5723-10M 6605555 5723 PUR • IP67 RSM-RKM5723-15M 6605556 5723 PUR • IP67 RSM-RKM5723-30M 6605559 5723 PUR • IP67 WSM5723-6M 6606055 5723 PUR • IP67 WSM5723-10M 6606057 5723 PUR • IP67 WSM5723-15M 6606058 5723 PUR • IP67 WKM5723-6M 6605314 5723 PUR • IP67 WKM5723-10M 6605316 5723 PUR • P67 WKM5723-15M 6605317 5723 PUR • IP67 WSM-WKM5723-0.3 M 6605660 5723 PUR • IP67 WSM-WKM5723-0.5 M 6605661 5723 PUR • IP67 WSM-WKM5723-1M 6605662 5723 PUR • IP67 WSM-WKM5723-2M 6605664 5723 PUR • IP67 WSM-WKM5723-4M 6605667 5723 PUR • IP67 WSM-WKM5723-6M 6605669 5723 PUR • IP67 WSM-WKM5723-10M 6605671 5723 PUR • IP67 WSM-WKM5723-15M 6605672 5723 PUR • IP67 WSM-WKM5723-30M 6605675 5723 PUR • IP67 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A1 A1 – 13 /0704 Vorkonfektionierte Buskabel für CAN (DeviceNet™, CANopen) open connector (OC) Premoulded Bus Cables for CAN (DeviceNet™, CANopen) open connector (OC) Konfektionierbare Steckverbinder siehe Seite A3 – 12 Field wireable connectors see page A3 – 12 Abmessungen/Bauform Anschluss Dimensions/Housing style Connection Steckverbinderausführung/ Maßbild Connector type/ dimension drawing [mm] 12345 1 = BK 2 = BU 3 = Bare 4 = WH 5 = RD 10,7 (V –) (CAN_L) (Shield) (CAN_H) (V +) (A) 12345 30,5 5,1 35 2 10,7 (A) M12 x 1 M12 x 1 w 55,2 (B) M12 x 1 ø 14,2 4 M12 x 1 11,5 48,5 12345 4 30,5 5,1 (A) 0,5 o (A) 1 v o (A) 2 v o (A) 0,5 v o (A) 1 v o (A) 2 v o (A) 0,5 v o (A) 1 v o (A) 2 w v (A) + (B) 0,5 w v (A) + (B) 1 w v (A) + (B) 2 v v (A) + (C) 0,5 v v (A) + (C) 1 v v (A) + (C) 2 3 4 3 5 10,7 o v 2 5 35 5 (V +) (V –) (CAN_H) (CAN_L) 1 (C) ø 20,5 ø 7,3 1 = shield 2 = RD 3 = BK 4 = WH 5 = BU v v 1 3 ø 14,2 18,2 Cable length [m] 5 4 3 2 1 30,5 5,1 35 Kabellänge w v (A) + (D) 0,5 2 w v (A) + (D) 1 1 w v (A) + (D) 2 w v (A) + (D) 0,5 w v (A) + (D) 1 w v (A) + (D) 2 v v (A) + (E) 0,5 v v (A) + (E) 1 v v (A) + (E) 2 4 v v (A) + (E) 0,5 5 v v (A) + (E) 1 v v (A) + (E) 2 (A) 7/8-16UN ø 27,0 ø 17,5 68,5 7/8“ w 36,0 1 = shield 2 = RD 3 = BK 4 = WH 5 = BU (V +) (V –) (CAN_H) (CAN_L) (D) 12345 30,5 5,1 35 10,7 (A) ø 20,5 ø 7,3 2 7/8-16UN 7/8“ ø 17,5 ø 27,0 65,0 29,0 (E) A1 – 14 /0704 v 3 1 1 = shield 2 = RD 3 = BK 4 = WH 5 = BU (V +) (V –) (CAN_H) (CAN_L) Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typenbezeichnung Ident-Nr. Kabeltyp Type Ident No. Cable type Material Kabelmantel Material cable jacket Schleppkettenfähig Schutzart Suited to trailing applications Degree of protection OC / M12 CBC5-572-0.5M 6606064 572 PVC – IP20 / – CBC5-572-1M 6602545 572 PVC – IP20 / – CBC5-572-2M 6606065 572 PVC – IP20 / – CBC5-5711-0,5M 6606091 5711 PVC – IP20 / – CBC5-5711-1M 6606092 5711 PVC – IP20 / – CBC5-5711-2M 6606093 5711 PVC – IP20 / – CBC5-5723-0,5M 6606097 5723 PUR • IP20 / – CBC5-5723-1M 6606098 5723 PUR • IP20 / – CBC5-5723-2M 6606099 5723 PUR • IP20 / – RSC-CBC5-572-0.5M 6602737 572 PVC – IP20 / IP67 RSC-CBC5-572-1M 6606133 572 PVC – IP20 / IP67 RSC-CBC5-572-2M 6602340 572 PVC – IP20 / IP67 RKC-CBC5-572-0.5M 6606103 572 PVC – IP20 / IP67 RKC-CBC5-572-1M 6606104 572 PVC – IP20 / IP67 RKC-CBC5-572-2M 6606105 572 PVC – IP20 / IP67 A1 RSM-CBC5-5711-0.5M 6606234 5711 PVC – IP20 / IP67 RSM-CBC5-5711-1M 6606235 5711 PVC – IP20 / IP67 RSM-CBC5-5711-2M 6606236 5711 PVC – IP20 / IP67 RSM-CBC5-5723-0.5M 6606240 5723 PUR • IP20 / IP67 RSM-CBC5-5723-1M 6606241 5723 PUR • IP20 / IP67 RSM-CBC5-5723-2M 6606242 5723 PUR • IP20 / IP67 RKM-CBC5-5711- 0.5M 6606195 5711 PVC – IP20 / IP67 RKM-CBC5-5711-1M 6606196 5711 PVC – IP20 / IP67 RKM-CBC5-5711-2M 6606197 5711 PVC – IP20 / IP67 RKM-CBC5-5723-0.5M 6606201 5723 PUR • IP20 / IP67 RKM-CBC5-5723-1M 6606202 5723 PUR • IP20 / IP67 RKM-CBC5-5723-2M 6606203 5723 PUR • IP20 / IP67 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A1 – 15 /0704 Vorkonfektionierte Buskabel für Ethernet Premoulded Bus Cables for Ethernet Abmessungen/Bauform Anschluss Dimensions/Housing style Connection Steckverbinderausführung/ Maßbild Connector type/ dimension drawing [mm] M12 x 1 55,2 M12 x 1 4 2 M12 x 1 v 15,2 w 6 5 M12 x 1 3 8 5 = WH/GN (RX+) 6 = WH/OG (TX+) 7 = BU 8 = GN (RX–) 1 = WH/BU 2 = WH/BN 3 = BN 4 = OG (TX–) ø 16,2 5 1 w (A) 48,5 Cable length [m] 6 7 ø 16,2 Kabellänge 7 1 4 2 8 3 w o (A) 6 w o (A) 10 w o (A) 15 v o (B) 6 v o (B) 10 v o (B) 15 v o (C) 6 v o (C) 10 v o (C) 15 w w (A) + (A) 0,5 w w (A) + (A) 1 w w (A) + (A) 2 w w (A) + (A) 4 w w (A) + (A) 6 w w (A) + (A) 10 w w (A) + (A) 15 (A) + (A) 30 (B) RJ45 12345678 (C) 6 7 ø 16,2 M12 x 1 55,2 5 = WH/BU 6 = GN (RX –) 7 = WH/BN 8 = BN 1 = WH/OG (TX+) 2 = OG (TX–) 3 = WH/GN (RX+) 4 = BU 42,2 M12 x 1 2 3 8 5 = WH/GN (RX +) 6 = WH/OG (TX +) 7 = BU 8 = GN (RX –) 1 = WH/BU 2 = WH/BN 3 = BN 4 = OG (TX–) 15,2 4 w (A) 5 1 RJ45 w 12345678 42,2 1 = WH/OG (TX+) 2 = OG (TX–) 3 = WH/GN (RX+) 4 = BU (C) 5 = WH/BU 6 = GN (RX –) 7 = WH/BN 8 = BN v v (C) + (C) 0,5 v v (C) + (C) 1 v v (C) + (C) 2 (C) + (C) 4 v v (C) + (C) 6 v v (C) + (C) 10 v v (C) + (C) 15 30 ø 16,2 M12 x 1 55,2 2 M12 x 1 M12 x 1 v 6 Pg 9 M12 x 1 1 4 2 2,5 18 15,2 (C) (A) + (C) 0,5 v v (B) + (C) 0,5 w o (D) 0,5 v o (E) 0,5 w w (A) + (D) 0,5 w v (A) + (E) 0,5 Pg 9 M12 x 1 v v w (C) + (D) 0,5 v v (C) + (E) 0,5 (E) (D) 42,2 M12 x 1 19,0 w v 7 3,0 max. M12 x 1 A1 – 16 /0704 5 = WH/GN (RX +) 6 = WH/OG (TX +) 7 = BU 8 = GN (RX –) 8 3 3,0 max. w 3 8 5 (B) 2,5 20,5 4 1 = WH/BU 2 = WH/BN 3 = BN 4 = OG (TX–) ø 16,2 5 1 w (A) 48,5 6 7 M12 x 1 RJ45 12345678 w 1 = WH/OG (TX+) 5 = WH/BU 6 = GN (RX –) 2 = OG (TX–) 3 = WH/GN (RX+) 7 = WH/BN 8 = BN 4 = BU Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typenbezeichnung Ident-Nr. Kabeltyp Type Ident No. Cable type Material Kabelmantel Material cable jacket Schleppkettenfähig Schutzart Suited to trailing applications Degree of protection RJ45 / M12 RSS-841-6M 6603696 841 PVC • IP67 / – RSS-841-10M 6603697 841 PVC • IP67 / – RSS-843-15M 6611000 843 PVC – IP67 / – RKS-841-6M 6603699 841 PVC • IP67 / – RKS-841-10M 6603700 841 PVC • IP67 / – RKS-843-15M 6611001 843 PVC – IP67 / – RJ45S-841-6M 6603710 841 PVC • IP20 / – RJ45S-841-10M 6603711 841 PVC • IP20 / – RJ45S-843-15M 6611004 843 PVC – IP20 / – RSS-RSS-841-0,5M 6603702 841 PVC • IP67 / IP67 RSS-RSS-841-1M 6603703 841 PVC • IP67 / IP67 RSS-RSS-841-2M 6603704 841 PVC • IP67 / IP67 RSS-RSS-841-4M 6603705 841 PVC • IP67 / IP67 RSS-RSS-841-6M 6603706 841 PVC • IP67 / IP67 RSS-RSS-841-10M 6603707 841 PVC • IP67 / IP67 RSS-RSS-843-15M 6611002 843 PVC – IP67 / IP67 RSS-RSS-843-30M 6611003 843 PVC – IP67 / IP67 RJ45S-RJ45S-841-0,5M 6603713 841 PVC • IP20 / IP20 RJ45S-RJ45S-841-1M 6603714 841 PVC • IP20 / IP20 RJ45S-RJ45S-841-2M 6603715 841 PVC • IP20 / IP20 RJ45S-RJ45S-841-4M 6603716 841 PVC • IP20 / IP20 RJ45S-RJ45S-841-6M 6603717 841 PVC • IP20 / IP20 RJ45S-RJ45S-841-10M 6603718 841 PVC • IP20 / IP20 RJ45S-RJ45S-843-15M 6611005 843 PVC – IP20 / IP20 RJ45S-RJ45S-843-30M 6611006 843 PVC – IP20 / IP20 RSS-RJ45S-841-0,5M 6603721 841 PVC • IP67 / IP20 RKS-RJ45S-841-0,5M 6603722 841 PVC • IP67 / IP20 FSSD-841-0,5M 6603723 841 PVC • IP67 / – FKSD-841-0,5M 6603724 841 PVC • IP67 / – RSS-FSSD-841-0,5M 6603725 841 PVC • IP67 / IP67 RSS-FKSD-841-0,5M 6603726 841 PVC • IP67 / IP67 RJ45S-FSSD-841-0,5M 6603727 841 PVC • IP20 / IP67 RJ45S-FKSD-841-0,5M 6603728 841 PVC • IP20 / IP67 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A1 A1 – 17 /0704 Vorkonfektionierte Versorgungskabel, 5 x 1,5 mm2, Typ 52 Premoulded Power Cables, 5 x 1,5 mm2, Type 52 Konfektionierbare Steckverbinder siehe Seite A4 – 4 Field wireable connectors see page A4 – 4 Abmessungen/Bauform Anschluss Dimensions/Housing style Connection Steckverbinderausführung/ Maßbild Connector type/ dimension drawing [mm] ø 8,5 Kabel-Meterware p – 30 Bulk cable p – 150 p – 500 ø 26,0 54,0 7/8“ 36,0 1= 2= 3= 4= 5= ø 26,0 2 3 1 (GND) (GND) (PE) (UB) (UL) 4 5 (B) ø 7,3 51,25 41,0 7/8“ ø 17,5 43,5 34,0 w 7/8-16UN ø 26,0 40,0 30,55 7/8-16UN ø 26,0 (D) A2 – 2 /0704 7/8“ v 2 1 o (A) 6 w o (A) 10 w o (A) 15 v o (B) 6 v o (B) 10 v o (B) 15 w v (A) + (B) 0,3 w v (A) + (B) 0,5 w v (A) + (B) 1 w v (A) + (B) 2 w v (A) + (B) 4 w v (A) + (B) 6 w v (A) + (B) 10 w v (A) + (B) 15 w v (A) + (B) 30 w o (C) 6 w o (C) 10 2 w o (C) 15 v o (D) 6 v o (D) 10 v o (D) 15 w v (C) + (D) 0,3 w v (C) + (D) 0,5 w v (C) + (D) 1 w v (C) + (D) 2 w v (C) + (D) 4 w v (C) + (D) 6 w v (C) + (D) 10 w v (C) + (D) 15 w v (C) + (D) 30 1 BK BU GN/YE BN WH 51,25 41,0 ø 17,5 3 5 1= 2= 3= 4= 5= (C) ø 7,3 4 w 1 BK BU GN/YE BN WH 2 7/8“ v 29,0 50,5 3 5 7/8-16UN ø 15,5 18,0 4 w (A) ø 8,5 Cable length [m] 7/8-16UN ø 15,5 Kabellänge 3 (GND) (GND) (PE) (UB) (UL) 4 5 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typenbezeichnung Ident-Nr. Kabeltyp Type Ident No. Cable type KABEL-PDP-52-30M 6604701 52 KABEL-PDP-52-150M 6604703 52 KABEL-PDP-52-500M 6604706 RSM52-6M RSM52-10M Material Kabelmantel Material cable jacket Schleppkettenfähig Schutzart Suited to trailing applications Degree of protection PUR • – PUR • – 52 PUR • – 6914142 52 PUR • IP67 6914143 52 PUR • IP67 RSM52-15M 6914144 52 PUR • IP67 RKM52-6M 6914145 52 PUR • IP67 RKM52-10M 6914146 52 PUR • IP67 RKM52-15M 6914147 52 PUR • IP67 RKM52-0,3-RSM52 6604743 52 PUR • IP67 RKM52-0,5-RSM52 6914148 52 PUR • IP67 RKM52-1-RSM52 6914149 52 PUR • IP67 RKM52-2-RSM52 6914150 52 PUR • IP67 RKM52-4-RSM52 6914151 52 PUR • IP67 RKM52-6-RSM52 6914152 52 PUR • IP67 RKM52-10-RSM52 6914153 52 PUR • IP67 RKM52-15-RSM52 6914154 52 PUR • IP67 RKM52-30-RSM52 6914306 52 PUR • IP67 WSM52-6M 6604788 52 PUR • IP67 WSM52-10M 6604790 52 PUR • IP67 WSM52-15M 6604791 52 PUR • IP67 WKM52-6M 6604770 52 PUR • IP67 WKM52-10M 6604772 52 PUR • IP67 WKM52-15M 6604773 52 PUR • IP67 WKM52-0,3-WSM52 6604797 52 PUR • IP67 WKM52-0,5-WSM52 6604798 52 PUR • IP67 WKM52-1-WSM52 6604799 52 PUR • IP67 WKM52-2-WSM52 6604801 52 PUR • IP67 WKM52-4-WSM52 6604804 52 PUR • IP67 WKM52-6-WSM52 6604806 52 PUR • IP67 WKM52-10-WSM52 6604808 52 PUR • IP67 WKM52-15-WSM52 6604809 52 PUR • IP67 WKM52-30-WSM52 6604812 52 PUR • IP67 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A2 – 3 /0704 A2 Vorkonfektionierte Versorgungskabel, 4 x 1,5 mm2, Typ 43 Premoulded Power Cables, 4 x 1,5 mm2, Type 43 Konfektionierbare Steckverbinder siehe Seite A4 – 8 Field wireable connectors see page A4 – 8 Abmessungen/Bauform Anschluss Dimensions/Housing style Connection Steckverbinderausführung/ Maßbild Connector type/ dimension drawing [mm] ø 8,5 Kabel-Meterware p – 30 Bulk cable p – 150 p – 500 ø 26,0 54,0 7/8“ 1 3 w 2 4 36,0 1 = RD 2 = GN 3 = WH 4 = BK (A) ø 8,5 ø 26,0 18,0 (Aux +) (E +) (E –) (Aux –) 7/8-16UN ø 15,5 Cable length [m] 7/8-16UN ø 15,5 Kabellänge 7/8“ v 29,0 50,5 3 1 4 2 w o (A) 6 w o (A) 10 w o (A) 15 v o (B) 6 v o (B) 10 v o (B) 15 w v (A) + (B) 0,3 w v (A) + (B) 0,5 w v (A) + (B) 1 w v (A) + (B) 2 w v (A) + (B) 4 w v (A) + (B) 6 w v (A) + (B) 10 w v (A) + (B) 15 w o (C) 6 w o (C) 10 w o (C) 15 v o (D) 6 v o (D) 10 v o (D) 15 w v (C) + (D) 0,3 w v (C) + (D) 0,5 w v (C) + (D) 1 (B) ø 7,3 51,25 41,0 ø 17,5 43,5 34,0 7/8“ 1 3 w 2 4 7/8-16UN ø 26,0 1 = RD 2 = GN 3 = WH 4 = BK (C) ø 7,3 51,25 41,0 ø 17,5 7/8“ v 40,0 30,55 7/8-16UN ø 26,0 (Aux +) (E +) (E –) (Aux –) 3 1 w v (C) + (D) 2 4 2 w v (C) + (D) 4 w v (C) + (D) 6 w v (C) + (D) 10 w v (C) + (D) 15 (D) A2 – 4 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typenbezeichnung Ident-Nr. Kabeltyp Type Ident No. Cable type KABEL-DN-43-30M 6915800 43 KABEL-DN-43-150M 6915802 43 KABEL-DN-43-500M 6915805 RSM43-6M RSM43-10M Material Kabelmantel Material cable jacket Schleppkettenfähig Schutzart Suited to trailing applications Degree of protection PUR • – PUR • – 43 PUR • – 6915621 43 PUR • IP67 6915622 43 PUR • IP67 RSM43-15M 6915623 43 PUR • IP67 RKM43-6M 6914307 43 PUR • IP67 RKM43-10M 6913941 43 PUR • IP67 RKM43-15M 6914310 43 PUR • IP67 RKM43-0,3-RSM43 6914319 43 PUR • IP67 RKM43-0,5-RSM43 6914311 43 PUR • IP67 RKM43-1-RSM43 6914312 43 PUR • IP67 RKM43-2-RSM43 6914313 43 PUR • IP67 RKM43-4-RSM43 6914314 43 PUR • IP67 RKM43-6-RSM43 6914315 43 PUR • IP67 RKM43-10-RSM43 6914316 43 PUR • IP67 RKM43-15-RSM43 6914317 43 PUR • IP67 WSM43-6M 6915844 43 PUR • IP67 WSM43-10M 6915845 43 PUR • IP67 WSM43-15M 6915846 43 PUR • IP67 WKM43-6M 6913940 43 PUR • IP67 WKM43-10M 6913941 43 PUR • IP67 WKM43-15M 6913942 43 PUR • IP67 WKM43-0,3-WSM43 6913948 43 PUR • IP67 WKM43-0,5-WSM43 6913949 43 PUR • IP67 WKM43-1-WSM43 6913950 43 PUR • IP67 WKM43-2-WSM43 6913951 43 PUR • IP67 WKM43-4-WSM43 6913916 43 PUR • IP67 WKM43-6-WSM43 6913918 43 PUR • IP67 WKM43-10-WSM43 6913917 43 PUR • IP67 WKM43-15-WSM43 6914328 43 PUR • IP67 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A2 – 5 /0704 A2 Vorkonfektionierte Versorgungskabel, 4 x 0,34 mm2 Premoulded Power Cables 4 x 0,34 mm2 Konfektionierbare Steckverbinder siehe Seite A5 – 12 Field wireable connectors see page A5 – 12 Abmessungen/Bauform Anschluss Dimensions/Housing style Connection Steckverbinderausführung/ Maßbild Connector type/ dimension drawing [mm] M8 x 1 ø 9,6 Kabellänge Cable length [m] v o (A) M8 x 1 4 BK 2 WH v o (A 5 v 3 BU 1 BN v o (A) 10 v o (B) 2 M8 x 1 4 BK 2 WH v o (B) 5 3 BU 1 BN v o (B) 10 w v (A) + (C) 0,15 M8 x 1 4 BK 2 WH w v (A) + (C) 0,5 v 3 BU 1 BN w v (A) + (C) 1 w v (A) + (C) 2 w v (A) + (C) 5 2 34 (A) 16,5 M8 x 1 28 ø 9,5 v (B) M8 x 1 ø 9,6 34 (A) M8 x 1 ø 9,6 41,2 M8 x 1 2 WH 4 BK w 1 BN 3 BU w v (B) + (D) 0,15 M8 x 1 4 BK 2 WH w v (B) + (D) 0,5 v 3 BU 1 BN w v (B) + (D) 1 w v (B) + (D) 2 w v (B) + (D) 5 (C) 16,5 M8 x 1 28 ø 9,5 (B) 23,5 28 M8 x 1 M8 x 1 2 WH 4 BK w 1 BN 3 BU ø 9,5 (D) A2 – 6 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typenbezeichnung Ident-Nr. Kabeltyp Type Ident No. Cable type IPSKP4-2/S90 6900323 – IPSKP4-5/S90 6900325 – IPSKP4-10/S90 6900321 IPSWKP4-2/S90 IPSWKP4-5/S90 Material Kabelmantel Material cable jacket Schleppkettenfähig Schutzart Suited to trailing applications Degree of protection PUR – – PUR – – – PUR – – 6900331 – PUR – – 6900333 – PUR – – IPSWKP4-10/S90 6900329 – PUR – – IPSKP4-0,15-SSP4/S90 6900334 – PUR – IP67 IPSKP4-0,5-SSP4/S90 6900320 – PUR – IP67 IPSKP4-1-SSP4/S90 6900322 – PUR – IP67 IPSKP4-2-SSP4/S90 6900324 – PUR – IP67 IPSKP4-5-SSP4/S90 6900326 – PUR – IP67 A2 IPSWKP4-0,15-SWSP4/S90 6900327 – PUR – IP67 IPSWKP4-0,5-SWSP4/S90 6900328 – PUR – IP67 IPSWKP4-1-SWSP4/S90 6900330 – PUR – IP67 IPSWKP4-2-SWSP4/S90 6900332 – PUR – IP67 IPSWKP4-5-SWSP4/S90 6900319 – PUR – IP67 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A2 – 7 /0704 T-Stücke/Y-Stücke für PROFIBUS-DP T-pieces/Y-pieces for PROFIBUS-DP Abmessungen Anwendung Dimensions Application Typenbezeichnung Ident-Nr. Type Ident no. RKSWS4.5[5]-2RSSWS 6999021 RKSW-2RSSW45-0001 6914180 VB2-FSW-FKW-FSW45 6996009 Verbindungstechnik Connection Fig. ( Fxxx ) (F030) (F048) 70 40,2 T-Stück für Bus, komplett geschirmt, 2 x M12 ( F048 ) 12 MBit/s, direkte Kopplung mehrerer 1 x M12 ( F030 ) T-Stücke nicht möglich 9,3 40,8 29,3 Bus tee, completely shielded, 12 MBit/s, direct coupling of multiple tees not possible ø 19 (F048) (F030) (F008) 70 40,2 9,3 40,8 29,3 T-Stück für Bus, komplett geschirmt, 1 x M12 ( F008 ) 12 MBit/s, direkte Kopplung mehrerer 1 x M12 ( F030 ) T-Stücke möglich 1 x M12 ( F048 ) Bus tee, completely shielded, 12 MBit/s, direct coupling of multiple tees possible ø 19 (F048) Trunk-Line 3) Drop-Line 23,0 M12 x 1 ø 4,5 ø 8,0 2 x M12 ( F048 ) 12 MBit/s, 1 x M12 ( F030 ) Y piece for bus, completely shielded, 12 MBit/s 38,0 18,0 M12 x 1 Y-Stück für Bus, komplett geschirmt, 25,0 13,0 M12 x 1 Anschlussbelegung Pin Configuration 4 5 v 2 2 3 1 1 2 3 4 5 1) w w 3 ( F030 )1) ( F008 )1 ) ( F006A ) = n. c. = GND = n. c. = UB = n. c. 4 1 2 3 4 5 2 1 1 5 5 = n. c. = Bus - A = n . c. = Bus - B = Shield 3 4 1 2 3 4 5 = 5 VDC = Bus - A = GND = Bus - B = Shield Invers codiert nach PNO-Richtlinie / Reverse-keyed acc. to PNO guidelines A3 – 2 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Abschlusswiderstände für PROFIBUS-DP Terminating Resistors for PROFIBUS-DP Typenbezeichnung Ident-Nr. Type Ident no. 1 x M12 ( F035 ) RSS4.5-PDP-TR 6601590 Aktiver Abschlusswiderstand 1 x M12 ( F035 ) PDP-TRA 6825346 Active terminating resistor 1 x 7/8“ ( F006A ) Abmessungen Anwendung Dimensions Application Verbindungstechnik Connection Fig. ( Fxxx ) Passiver Abschlusswiderstand 43,0 Passive terminating resistor 22,1 14,2 ø 16,4 M12 x 1 8,5 85 42,5 10 M12 x 1 7/8-16UN M18 x 1 24/4 A3 Anschlussbelegung Pin Configuration ( F035 )1) w 390 W 1/4 W 5 4 390 W 3 1/4 W 2 2 3 ) ) v w 2 3 1 1 2 3 4 5 (F048)1) ( F037 ) = 5 VDC2 ) = Bus - A = GND = Bus - B = Shield 220 W 1/4 W 2 4 1 5 1 2 3 4 5 = GND = GND = PE = UB = UL 3 1 4 1 2 3 4 5 5 = 5 VDC = Bus - A = GND = Bus - B = Shield Nur an Bus-Kupplung / Female bus connector only Anschluss von zwei konfektionierbaren Steckverbindern an der Trunk-Line nicht möglich/Connection of two field wireable connectors to the trunk line not possible Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A3 – 3 /0704 Konfektionierbare Steckverbinder für PROFIBUS-DP Field wireable Connectors for PROFIBUS-DP Abmessungen Anwendung Dimensions Application Typenbezeichnung Ident-Nr. Type Ident no. 1 x M12 ( F034 ) BMWS 8151-8,5 6904721 1 x M12 ( F008 ) BMSWS 8151-8,5 6904722 1 x M12 ( F034 ) BMWS 8251-8,5 6904723 1 x M12 ( F008 ) BMSWS 8251-8,5 6904724 Verbindungstechnik Connection Fig. ( Fxxx ) Konfektionierbare M12-Kupplung, gerade, schirmbar M12 x 1 » 57 Field wireable female M12 connector, ø 8,5 ø 19,6 straight, shieldable Konfektionierbarer M12-Stecker, M12 x 1 gerade, schirmbar » 62 Field wireable male M12 connector, ø 8,5 ø 19,6 M12 x 1 36,9 18,7 straight, shieldable Konfektionierbare M12-Kupplung, abgewinkelt, schirmbar ø 19,6 31,1 » 55 Field wireable female M12 connector, right-angle, shieldable ø 18 ø 8,5 41,8 Konfektionierbarer M12-Stecker, 18,7 abgewinkelt, schirmbar ø 19,6 31,1 M12 x 1 » 55 Field wireable male M12 connector, right-angle, shieldable ø 18 ø 8,5 Anschlussbelegung Pin Configuration ( F008 )1 ) ( F034 )1 ) w v 2 3 4 1) v 45° 2 1 1 2 3 4 5 ( F034B )1 ) 5 = n. c. = Bus - A = n. c. = Bus - B = Shield 1 5 1 2 3 4 5 4 3 4 = n. c. = Bus - A = n. c. = Bus - B = Shield 5 1 3 2 1 2 3 4 5 = n. c. = Bus - A = n. c. = Bus - B = Shield Invers codiert nach PNO-Richtlinie / Reverse-keyed acc. to PNO guidelines A3 – 4 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Flansche für PROFIBUS-DP Flange Connectors for PROFIBUS-DP Abmessungen Anwendung Dimensions Application Typenbezeichnung Ident-Nr. Type Ident no. 1 x M12 ( F034 ) FKW4.54-0,5 8016042 1 x M12 ( F034 ) FKDW4.54-0,5 8015777 1 x M12 ( F034B ) FKFDW4.54-0,5 8016041 1 x M12 ( F034 ) FKW5L 8016718 Verbindungstechnik Connection Fig. ( Fxxx ) Flansch, M12-Kupplung, Pg 9 frontseitig schraubbar, M12 x 1 5 x 0,34 mm2 invers codiert, 0,5 m Litze M12 female flange connector, 17 ø 18 19 front panel screw mounting, reverse-keyed, 0.5 m litz wire Flansch, M12-Kupplung, frontseitig schraubbar, Pg 9 M12 x 1 invers codiert, drehbar, 0,5 m Litze M12 female connector flange connector, 5 x 0,34 mm2 17 ø 18 21 rotable, front panel screw mounting, reverse-keyed, 0.5 m litz wire Flansch, M12-Kupplung, 19 13,5 Rückwandmontage, Pg 9 ø 13,5 invers codiert, 0,5 m Litze M12 female flange connector, 5 x 0,34 mm2 back panel screw mounting, ø 21,5 17 reverse-keyed, 0.5 m litz wire Flansch, M12-Kupplung, frontseitig schraubbar, Pg 9 M12 x 1 5 x 0,34 mm2 invers codiert M12 female flange connector, 17 ø 18 18,5 front panel screw mounting, reverse-keyed A3 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A3 – 5 /0704 Flansche für PROFIBUS-DP Flange Connectors for PROFIBUS-DP Abmessungen Anwendung Dimensions Application Typenbezeichnung Ident-Nr. Type Ident no. 1 x M12 ( F008 ) FSW4.54-0,5 8016038 1 x M12 ( F008 ) FSDW4.54-0,5 8015776 1 x M12 ( F008B ) FSFDW4.54-0,5 8016043 1 x M12 ( F008 ) FSW5L 8016717 Verbindungstechnik Connection Fig. ( Fxxx ) Flansch, M12-Stecker, Pg 9 frontseitig schraubbar, M12 x 1 5 x 0,34 mm2 invers codiert, 0,5 m Litze M12 male flange connector, ø 18 17 19 front panel screw mounting, reverse-keyed, 0.5 m litz wire Flansch, M12-Stecker, Pg 9 frontseitig schraubbar, M12 x 1 5 x 0,34 mm2 17 invers codiert, drehbar, 0,5 m Litze M12 male flange connector, ø 18 26,5 rotable, front panel screw mounting, reverse-keyed, 0.5 m litz wire Flansch, M12-Stecker, 19 Rückwandmontage, 13,5 M12 x 1 Pg 9 invers codiert, 0,5 m Litze M12 male flange connector, 2 5 x 0,34 mm back panel screw mounting, ø 21,5 21,5 reverse-keyed, 0.5 m litz wire Flansch, M12-Stecker, frontseitig schraubbar, Pg 9 invers codiert M12 x 1 M12 male flange connector, 5 x 0,34 mm2 ø 18 17 19 rotable, front panel screw mounting, reverse-keyed Anschlussbelegung Pin Configuration ( F008 )1 ) ( F008B )1 ) w 4 1) 2 4 1 1 2 3 4 5 v w 2 3 ( F034 )1 ) 1 1 3 2 5 = n. c. = Bus - A = n. c. = Bus - B = Shield 3 1 2 3 4 5 = n. c. = Bus - A = n. c. = Bus - B = Shield 45° 5 1 2 3 4 5 4 = n. c. = Bus - A = n. c. = Bus - B = Shield Invers codiert nach PNO-Richtlinie / Reverse-keyed acc. to PNO guidelines A3 – 6 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Durchführungen für PROFIBUS-DP Feed-through Receptacles for PROFIBUS-DP Abmessungen Anwendung Dimensions Application Verbindungstechnik Connection Typenbezeichnung Ident-Nr. Type Ident no. FKW-FSW-45-M12 6602309 Fig. ( Fxxx ) 47.4 29.4 O-ring M12-Durchführung, 1 x M12 ( F008 ) gerader Stecker/Kupplung, für invers 1 x M12 ( F034 ) codierte M12-Buskabel M12 x 1 M12 x 1 locknut LN-M12 Feed-through receptacle, M12, straight male/female connector, for lockwasher LW-M12 premoulded, reverse-keyed M12 bus cables A3 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A3 – 7 /0704 T-Stücke für CAN (DeviceNet™, CANopen) T-pieces for CAN (DeviceNet™, CANopen) Abmessungen Anwendung Dimensions Application Typenbezeichnung Ident-Nr. Type Ident no. RSM-FKM-RKM57 6602392 FSM-2FKM57 8011661 RSM-2RKM57 6602007 Verbindungstechnik Connection Fig. ( Fxxx ) 73,0 37,4 7/8-16UN 28,0 T-Stück (7/8“/M12) für Bus und 1 x 7/8“ ( F006 ) Versorgung 1 x 7/8“ ( F037 ) Tee (7/8“/M12) for bus and power 1 x M12 ( F032 ) T-Stück (M12/M12) für Bus und 2 x M12 ( F032 ) Versorgung 1 x M12 ( F008 ) 17,5 31,5 ø 26,0 7/8-16UN M12 x 1 56 23,5 Tee (M12/M12) for bus and power ø 15 23,5 M12 x 1 M12 x 1 73,0 37,4 T-Stück (7/8“/7/8“) für Bus und 1 x 7/8“ ( F006 ) Versorgung 2 x 7/8“ ( F037 ) 7/8-16UN 28,0 17,5 Tee (7/8“/7/8“) for bus and power 34,8 ø 26,0 7/8-16UN 7/8-16UN ø 26,0 Anschlussbelegung Pin Configuration 4 ( F006 ) ( F031 ) w w 3 2 5 1 1 2 3 4 5 = Shield =V+ =V– = CAN_H = CAN_L ) ( F037 ) v v 2 2 1 3 4 1 ( F032 ) 1 2 3 4 5 5 = Shield =V+ =V– = CAN_H = CAN_L 3 1 5 1 2 3 4 5 3 2 4 1 5 1 2 3 4 5 = Shield =V+ =V– = CAN_H = CAN_L 4 = Shield =V+ =V– = CAN_H = CAN_L Anschluss von zwei konfektionierbaren Steckverbindern an der Trunk-Line nicht möglich/Connection of two field wireable connectors to the trunk line not possible A3 – 8 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Y-Stücke für CAN (DeviceNet™, CANopen) Y-pieces for CAN (DeviceNet™, CANopen) Abmessungen Anwendung Dimensions Application Verbindungstechnik Connection Typenbezeichnung Ident-Nr. Type Ident no. VB2-FKM-FKM-FSM57 6602331 VB2-FKM-RKC-RSC572-0,5M-0,5M 6602490 VB2-RKC572-1M-FKM-FSM 6996011 VB2-FKM-FKM-RSC572-1M 6602613 Fig. ( Fxxx ) Trunk-Line 1) Drop-Line 23,0 ø 4,5 M12 x 1 Y-Stück für Bus 1) 2 x M12 ( F032 ) Y piece for bus 1) 1 x M12 ( F031 ) Y-Stück für Bus 2 x M12 ( F032 ) Y piece for bus 1 x M12 ( F031 ) Y-Stück für Bus und Versorgung 1) 2 x M12 ( F032 ) Y piece for bus and power 1) 1 x M12 ( F031 ) Y-Stück für Bus und Versorgung 2 x M12 ( F032 ) Y piece for bus and power 1 x M12 ( F031 ) ø 8,0 38,0 18,0 25,0 13,0 M12 x 1 M12 x 1 23,0 ø 4,5 38,0 18,0 ø 8,0 25,0 M12 x 1 ø 5,2 Trunk-Line 1) 13,0 M12 x 1 Drop-Line 23 ø 4,5 ø8 M12 x 1 18 38 25 M12 x 1 M12 x 1 13 23,0 0,3 m 38,0 18,0 ø 5,2 M12 x 1 ø 4,5 ø 8,0 25,0 M12 x 1 13,0 M12 x 1 A3 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A3 – 9 /0704 Abschlusswiderstände für CAN (DeviceNet™, CANopen) Terminating Resistors for CAN (DeviceNet™, CANopen) Abmessungen Anwendung Dimensions Application Typenbezeichnung Ident-Nr. Type Ident no. 1 x 7/8“ ( F036A ) RSM57-TR2 6602011 1 x 7/8“ ( F036B ) RKM57-TR2 6602065 1 x M12 ( F038A ) RSE57-TR2 6602308 1 x M12 ( F038B ) RKE57-TR2 6602629 Verbindungstechnik Connection Fig. ( Fxxx ) Abschlusswiderstand (Stecker) 7/8-16UN 48,5 Terminating resistor (male connector) ø 26,0 36,0 44,6 7/8-16UN Abschlusswiderstand (Kupplung) Terminating resistor (female connector) ø 26,0 29,0 Abschlusswiderstand (Stecker) 12,5 M12 x 1 Terminating resistor (male connector) ø 14,2 4,0 48,5 18,0 M12 x 1 ø 16,2 Abschlusswiderstand (Kupplung) Terminating resistor (female connector) 48,5 Anschlussbelegung Pin Configuration 4 5 ( F006 ) ( F031 ) w w 3 2 2 1 4 1 2 3 4 5 A3 – 10 /0704 = Shield =V+ =V– = CAN_H = CAN_L 1 2 3 4 5 = Shield =V+ =V– = CAN_H = CAN_L ( F036A ) v w 2 1 3 ( F032 ) 5 3 1 5 4 1 2 3 4 5 = Shield =V+ =V– = CAN_H = CAN_L 4 120 W 1/4 W 3 5 1 2 3 4 5 2 1 = Shield =V+ =V– = CAN_H = CAN_L Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Passiv-Verteiler für CAN (DeviceNet™, CANopen) Junction Tees for CAN (DeviceNet™, CANopen) Abmessungen Anwendung Dimensions Application Verbindungstechnik Connection Typenbezeichnung Ident-Nr. Type Ident no. JTBS57-E434 6603554 JTBS57-E634 6603555 JTBS57-M434 6603556 JTBS57-M634 6603557 Fig. ( Fxxx ) 33,0 P1 4fach-Passiv-Verteiler, IP67 1 x 7/8“ ( F006 ) 4-port passive multiport junction, IP67 1 x 7/8“ ( F037 ) 4 x M12 ( F032 ) JTBS-57-M634 222,9 J0 J1 J2 J3 J4 33,0 P1 6fach-Passiv-Verteiler, IP67 1 x 7/8“ ( F006 ) 6-port passive multiport junction, IP67 1 x 7/8“ ( F037 ) J0 6 x M12 ( F032 ) JTBS-57-M634 222,9 J1 J2 J3 J4 J5 J6 33,0 P1 4fach-Passiv-Verteiler, IP67 1 x 7/8“ ( F006 ) 4-port passive multiport junction, IP67 5 x 7/8“ ( F037 ) 6fach-Passiv-Verteiler, IP67 1 x 7/8“ ( F006 ) 6-port passive multiport junction, IP67 7 x 7/8“ ( F037 ) JTBS-57-M634 222,9 J0 J1 J2 J3 J4 33,0 P1 J0 JTBS-57-M634 222,9 J1 J2 J3 J4 J5 J6 A3 Anschlussbelegung Pin Configuration 3 2 1 ( F036B ) ( F038A ) v w ( F038B ) v 2 4 5 120 W 1/4 W 120 W 1/4 W 3 4 1 2 3 4 5 = Shield =V+ =V– = CAN_H = CAN_L 1 2 3 4 5 = Shield =V+ =V– = CAN_H = CAN_L 2 1 1 5 5 3 4 1 2 3 4 5 120 W 1/4 W = Shield =V+ =V– = CAN_H = CAN_L Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A3 – 11 /0704 Konfektionierbare Steckverbinder für CAN (DeviceNet™, CANopen) Field wireable Connectors for CAN (DeviceNet™, CANopen) Abmessungen Anwendung Dimensions Application Typenbezeichnung Ident-Nr. Type Ident no. 1 x 7/8“ ( F037 ) B4151-0/9 6904717 1 x 7/8“ ( F006 ) BS4151-0/9 6904718 1 x 7/8“ ( F037 ) B4251-0/9 6901113 1 x 7/8“ ( F006 ) BS4251-0/9 6901112 Verbindungstechnik Connection Fig. ( Fxxx ) Konfektionierbare 7/8“-Kupplung, gerade, Kabelauslass Pg9, 85 max. Kabeldurchmesser: 6...8 mm Pg 9 ø 27 Field wireable female 7/8“ connector, straight, cable outlet Pg9, 7/8-16UN max. cable diameter: 6...8 mm Konfektionierbarer 7/8“-Stecker, gerade, Kabelauslass Pg9, max. Kabeldurchmesser: 6...8 mm 88 Pg 9 ø 27 Field wireable male 7/8“ connector, straight, cable outlet Pg9, 7/8-16UN max. cable diameter: 6...8 mm Konfektionierbare 7/8“-Kupplung, 61,5 abgewinkelt, Kabelauslass Pg9, max. Kabeldurchmesser: 6...8 mm 33 ø 27 Field wireable female 7/8“ connector, right-angle, cable outlet Pg9, Pg9 max. cable diameter: 6...8 mm Konfektionierbarer 7/8“-Stecker, 65 abgewinkelt, Kabelauslass Pg9, max. Kabeldurchmesser: 6...8 mm 33 ø 27 Pg9 Field wireable male 7/8“ connector, right-angle, cable outlet Pg9 max. cable diameter: 6...8 mm Anschlussbelegung Pin Configuration ( F006 ) ( F031 ) w w 3 2 4 5 2 1 4 1 2 3 4 5 A3 – 12 /0704 = Shield =V+ =V– = CAN_H = CAN_L 1 2 3 4 5 = Shield =V+ =V– = CAN_H = CAN_L ( F037 ) v v 2 1 3 ( F032 ) 5 3 3 1 5 4 1 2 3 4 5 = Shield =V+ =V– = CAN_H = CAN_L 2 4 1 5 1 2 3 4 5 = Shield =V+ =V– = CAN_H = CAN_L Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Abmessungen Anwendung Dimensions Application Typenbezeichnung Ident-Nr. Type Ident no. 1 x 7/8“ ( F037 ) B4151-0/13,5 6904715 1 x 7/8“ ( F006 ) BS4151-0/13,5 6904716 1 x M12 ( F032 ) B8151-0/9 6904604 1 x M12 ( F031 ) BS8151-0/9 6904613 1 x M12 ( F032 ) B8251-0/9 6904603 Verbindungstechnik Connection Fig. ( Fxxx ) Konfektionierbare 7/8“-Kupplung, gerade, Kabelauslass Pg13,5, 85 max. Kabeldurchmesser: 10...14 mm Pg 13,5 ø 27 Field wireable female 7/8“ connector, straight, cable outlet Pg13,5, 7/8-16UN max. cable diameter: 10...14 mm Konfektionierbarer 7/8“-Stecker, gerade, Kabelauslass Pg13,5, 88 max. Kabeldurchmesser: 10...14 mm Pg 13,5 ø 27 7/8-16UN Field wireable male 7/8“ connector, straight, cable outlet Pg13,5, max. cable diameter: 10...14 mm Konfektionierbare M12 x 1-Kupplung, gerade, Kabelauslass Pg9, 54 M12 x 1 max. Kabeldurchmesser: 6...8 mm ø 19,5 Pg 9 Field wireable female M12 x 1 connector, straight, cable outlet Pg9, max. cable diameter: 6...8 mm Konfektionierbarer M12 x 1-Stecker, gerade, Kabelauslass Pg9, 58 max. Kabeldurchmesser: 6...8 mm ø 19,5 Pg 9 straight, cable outlet Pg9, M12 x 1 M12 x 1 Field wireable male M12 x 1 connector, max. cable diameter: 6...8 mm Konfektionierbare M12 x 1-Kupplung, 36 A3 abgewinkelt, Kabelauslass Pg9, max. Kabeldurchmesser: 6...8 mm 19,5 39 Field wireable female M12 x 1 connector, right-angled, cable outlet Pg9, max. cable diameter: 6...8 mm Pg 9 Konfektionierbarer M12 x 1-Stecker, 41,5 1 x M12 ( F031 ) BS8251-0/9 6904615 abgewinkelt, Kabelauslass Pg9, max. Kabeldurchmesser: 6...8 mm 19,5 39 M12 x 1 Field wireable male M12 x 1 connector, right-angled, cable outlet Pg9, Pg 9 max. cable diameter: 6...8 mm Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A3 – 13 /0704 Flansche für CAN (DeviceNet™, CANopen) Flange Connectors for CAN (DeviceNet™, CANopen) Abmessungen Anwendung Dimensions Application Typenbezeichnung Ident-Nr. Type Ident no. 1 x 7/8“ ( F037 ) RKF57 6602217 1 x 7/8“ ( F006 ) RSF57 6902342 1 x M12 ( F032 ) FK57 6602216 1 x M12 ( F031 ) FS57 6902314 Verbindungstechnik Connection Fig. ( Fxxx ) Lötbare 7/8"-Kupplung, 19,5 10 gerade Kupplung, zur Verwendung mit ø 25,4 1/2-14 NPT 26 7/8-16UN female connector, for use with CAN thin and mid cables Lötbarer 7/8"-Stecker, gerader Stecker, 26,5 10 dünnen und mittleren CAN-Kabeln 7/8" field solderable receptacle, straight 7,5 zur Verwendung mit dünnen und ø 25,4 mittleren CAN-Kabeln 7/8" field solderable receptacle, straight 1/2-14 NPT 26 7/8-16UN male connector, for use with CAN thin and mid cables Lötbare M12-Kupplung, gerade Kupplung, 23 ø 13,5 ø 18 7 Pg 9 13 M12 x 1 zur Verwendung mit dünnen CAN-Kabeln M12 field solderable receptacle, straight female connector, for use with CAN thin cables Lötbarer M12-Stecker, gerader Stecker, 22 6 13 zur Verwendung mit dünnen CAN-Kabeln M12 field solderable receptacle, ø 18 Pg 9 straight male connector, for use with M12 x 1 CAN thin cables Anschlussbelegung Pin Configuration ( F006 ) ( F031 ) w w 4 5 3 2 4 A3 – 14 /0704 v 1 3 = Shield =V+ =V– = CAN_H = CAN_L 1 2 3 4 5 = Shield =V+ =V– = CAN_H = CAN_L ( F037 ) v 2 2 1 1 2 3 4 5 ( F032 ) 5 3 3 1 5 4 1 2 3 4 5 = Shield =V+ =V– = CAN_H = CAN_L 2 4 1 5 1 2 3 4 5 = Shield =V+ =V– = CAN_H = CAN_L Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Durchführungen für CAN (DeviceNet™, CANopen) Feed-through Receptacles for CAN (DeviceNet™, CANopen) Abmessungen Anwendung Dimensions Application Verbindungstechnik Connection Typenbezeichnung Ident-Nr. Type Ident no. RSF-RKF-57/22 6602218 FKM-FS57-M12 6602223 Typenbezeichnung Ident-Nr. Type Ident no. BIC-84-E424 6604474 Fig. ( Fxxx ) 49.2 32.7 7/8-16UN 7/8"-Durchführung, gerader Stecker/ 1 x 7/8“ ( F006 ) Kupplung, zur Verwendung mit 1 x 7/8“ ( F037 ) vorkonfektionierten 7/8"-Kabeln 7/8" bulkhead receptacle, straight male/ 7/8-16UN locknut lockwasher sealing gasket thrust washer female feed-thru, for use with 7/8" cordsets 47.4 29.4 O-ring M12 x 1 M12-Durchführung, gerader Stecker/ 1 x M12 ( F031 ) Kupplung, zur Verwendung mit 1 x M12 ( F032 ) vorkonfektionierten M12-Kabeln M12 bulkhead receptacle, straight male/ M12 x 1 locknut LN-M12 lockwasher LW-M12 female feed-thru, for use with M12 cordsets M12/RJ45-Umsetzer für Ethernet M12/RJ45 Adapter for Ethernet Abmessungen Anwendung Dimensions Application Verbindungstechnik Connection Fig. ( Fxxx ) 140 4,3 Vierkanaliger M12/RJ45-Adapter, 1 x M12 ( F049 ) Schnittstelle zwischen IP20- und IP67- 1 x RJ45 ( F050 ) 130 Umgebung Four-channel M12/RJ45-adapter, 32 52 13 A3 interface between IP 20 and IP67 environments Anschlussbelegung Pin Configuration ( F049 ) ( F050 ) v v 5 6 7 1 4 8 3 1 2 3 4 = n. c. = n. c.. = n. c. = Tx – 2 5 6 7 8 12345678 = RX + = TX + = n. c. = RX – 1 2 3 4 = TX + = TX – = RX + = n. c. 5 6 7 8 = n. c. = RX – = n. c. = n. c. Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A3 – 15 /0704 A4 – 2 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com T-Stücke für Versorgungskabel, 5 x 1,5 mm2, Typ 52 T-pieces for Power Cables, 5 x 1,5 mm2, Type 52 Abmessungen Anwendung Dimensions Application Verbindungstechnik Connection Typenbezeichnung Ident-Nr. Type Ident no. RSM-2RKM50 6914950 Fig. ( Fxxx ) 73,0 37,4 T-Stück für Versorgung 2 x 7/8“ ( F037 ) Power tee 1 x 7/8“ ( F006B ) 7/8-16UN 28,0 17,5 34,8 ø 26,0 7/8-16UN 7/8-16UN ø 26,0 Anschlussbelegung Pin Configuration ( F006B ) w 3 4 5 = GND = GND = PE = UB = UL v 3 2 1 1 2 3 4 5 A4 ( F037 ) 2 4 1 5 1 2 3 4 5 = GND = GND = PE = UB = UL Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A4 – 3 /0704 Konfektionierbare Steckverbinder für Versorgungskabel, 5 x 1,5 mm2, Typ 52 Field wireable Connectors for Power Cables, 5 x 1,5 mm2, Type 52 Abmessungen Anwendung Dimensions Application Typenbezeichnung Ident-Nr. Type Ident no. 1 x 7/8“ ( F037 ) B4151-0/9 6904717 1 x 7/8“ ( F006 ) BS4151-0/9 6904718 1 x 7/8“ ( F037 ) B4251-0/9 6901113 1 x 7/8“ ( F006 ) BS4251-0/9 6901112 Verbindungstechnik Connection Fig. ( Fxxx ) Konfektionierbare 7/8“-Kupplung, gerade, Kabelauslass Pg9, 85 max. Kabeldurchmesser: 6...8 mm Pg 9 ø 27 Field wireable female 7/8“ connector, straight, cable outlet Pg9, 7/8-16UN max. cable diameter 6...8 mm Konfektionierbarer 7/8“-Stecker, 88 gerade, Kabelauslass Pg9, Pg 9 ø 27 max. Kabeldurchmesser: 6...8 mm Field wireable male 7/8“ connector, 7/8-16UN straight, cable outlet Pg9, max. cable diameter 6...8 mm Konfektionierbare 7/8“-Kupplung, 61,5 abgewinkelt, Kabelauslass Pg9, max. Kabeldurchmesser: 6...8 mm 33 ø 27 Field wireable female 7/8“ connector, right-angle, cable outlet Pg9, Pg9 max. cable diameter 6...8 mm Konfektionierbarer 7/8“-Stecker, 65 abgewinkelt, Kabelauslass Pg9, max. Kabeldurchmesser: 6...8 mm 33 ø 27 Field wireable male 7/8“ connector, right-angle, cable outlet Pg9, Pg9 Anschlussbelegung Pin Configuration max. cable diameter 6...8 mm ( F006 ) ( F037 ) w v 4 3 5 1 2 3 4 5 A4 – 4 /0704 1 = GND = GND = PE = UB = UL 3 2 2 4 1 5 1 2 3 4 5 = GND = GND = PE = UB = UL Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Durchführungen/Flansche für Versorgungskabel, 5 x 1,5 mm2, Typ 52 Feed-through Receptacles/Flange Connectors for Power Cables, 5 x 1,5 mm2, Type 52 Abmessungen Anwendung Dimensions Application Typenbezeichnung Ident-Nr. Type Ident no. RSF-RKF-57/22 6602218 1 x 7/8“ ( F006 ) RSF57 6902342 1 x 7/8“ ( F037 ) RKF57 6602217 Verbindungstechnik Connection Fig. ( Fxxx ) 49.2 32.7 7/8-16UN 7/8-16UN locknut lockwasher 7/8"-Durchführung, gerader Stecker/ 1 x 7/8“ ( F006 ) Kupplung, zur Verwendung mit vor- 1 x 7/8“ ( F037 ) konfektionierten 7/8"-Kabeln 7/8" bulkhead receptacle, straight male/ sealing gasket thrust washer female feed-thru, for use with 7/8" cordsets 19,5 Lötbarer 7/8“-Flanschstecker 10 7/8" field solderable receptacle, ø 25,4 1/2-14 NPT 26 7/8-16UN 26,5 10 Lötbare 7/8“-Flanschkupplung 7,5 ø 25,4 1/2-14 NPT 26 male connector 7/8" field solderable receptacle, female connector 7/8-16UN A4 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A4 – 5 /0704 A4 – 6 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com T-Stücke für Versorgungskabel, 4 x 1,5 mm2, Typ 43 T-pieces for Power Cables, 4 x 1,5 mm2, Type 43 Abmessungen Anwendung Dimensions Application Verbindungstechnik Connection Typenbezeichnung Ident-Nr. Type Ident no. RSM-2RKM40 6914828 RKM40-RKM40-L-RSM40 6914866 Fig. ( Fxxx ) 73,0 37,4 7/8-16UN 28,0 17,5 T-Stück für Auxiliary-Power 1 x 7/8“ ( F023A ) Tee for auxiliary power 2 x 7/8“ ( F023B ) 34,8 ø 26,0 7/8-16UN 7/8-16UN ø 26,0 73,0 37,4 7/8-16UN 28,0 17,5 34,8 ø 26,0 7/8-16UN 7/8-16UN T-Stück für Auxiliary-Power 1 x 7/8“ ( F023A ) (Keyway facing female) 2 x 7/8“ ( F023B ) Tee for auxiliary power (Keyway facing female) ø 26,0 Anschlussbelegung Pin Configuration ( F023A ) ( F023B ) w v 1 3 3 1 2 4 4 2 1 2 3 4 = Aux + =E+ =E= Aux - 1 2 3 4 A4 = Aux + =E+ =E= Aux - Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A4 – 7 /0704 Konfektionierbare Steckverbinder für Versorgungskabel, 4 x 1,5 mm2, Typ 43 Field wireable Connectors for Power Cables, 4 x 1,5 mm2, Type 43 Abmessungen Anwendung Dimensions Application Typenbezeichnung Ident-Nr. Type Ident no. 1 x 7/8“ ( F023B ) B4148-0/9 6914925 1 x 7/8“ ( F023A ) BS4148-0/9 6914522 Verbindungstechnik Connection Fig. ( Fxxx ) 85 Konfektionierbare 7/8“-Kupplung, Pg 9 ø 27 Kabelauslass Pg9, max. Kabeldurchmesser: 6...8 mm 7/8-16UN Field wireable 7/8“ female connector, cable outlet Pg9, max. cable diameter 6...8 mm Konfektionierbarer 7/8“-Stecker, 88 Pg 9 ø 27 7/8-16UN Kabelauslass Pg9, max. Kabeldurchmesser: 6...8 mm Field wireable 7/8“ male connector, cable outlet Pg9, max. cable diameter 6...8 mm Anschlussbelegung Pin Configuration ( F023A ) w v 1 3 3 1 2 4 4 2 1 2 3 4 A4 – 8 /0704 ( F023B ) = Aux + =E+ =E= Aux - 1 2 3 4 = Aux + =E+ =E= Aux - Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Durchführungen/Flansche für Versorgungskabel, 4 x 1,5 mm2, Typ 43 Feed-through Receptacles/Flanged connectors for Power Cables, 4 x 1,5 mm2, Type 43 Abmessungen Anwendung Dimensions Application Typenbezeichnung Ident-Nr. Type Ident no. RSF-RKF-40/22 6915014 1 x 7/8“ ( F023A ) RSFL46 6914836 1 x 7/8“ ( F023B ) RKFL46 6915086 Verbindungstechnik Connection Fig. ( Fxxx ) 49.2 32.7 7/8-16UN 7/8"-Durchführung, gerader Stecker/ 1 x 7/8“ ( F023A ) Kupplung, zur Verwendung mit vor- 1 x 7/8“ ( F023B ) konfektionierten 7/8"-Kabeln 7/8" bulkhead receptacle, straight male/ 7/8-16UN locknut lockwasher sealing gasket thrust washer female feed-thru, for use with 7/8" cordsets 26,5 10 Lötbarer 7/8“-Flanschstecker 7,5 ø 25,4 1/2-14 NPSM 26 male connector 7/8-16UN Lötbare 7/8“-Flanschkupplung 19,5 10 7/8" field solderable receptacle, ø 25,4 1/2-14 NPSM 7/8" field solderable receptacle, 26 female connector 7/8-16UN A4 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A4 – 9 /0704 Steckverbinder-Systeme für Sensoren und Aktuatoren (Ø 8 mm/M8 x 1) Connector Systems for Sensors and Actuators (Ø 8 mm/M8 x 1) Abmessungen/Bauform Anschluss Leitung/Cable Dimensions/Housing style Pin configuration [mm] 00783600.gifw Ø 8 mm e ø 8,6 00783600.gif 4 BK 1 BN 3 BU Querschnitt Cross section Adernaufbau Conductor construction Länge Length Qualität Quality Farbe Colour Durchmesser Diameter [ mm2 ] [ mm Ø] [m] 3 x 0,25 32 x 0,1 2 PUR GY 4,4 3 x 0,25 32 x 0,1 5 PUR GY 4,4 3 x 0,25 32 x 0,1 10 PUR GY 4,4 3 x 0,25 32 x 0,1 2 PUR GY 4,4 3 x 0,25 32 x 0,1 5 PUR GY 4,4 3 x 0,25 32 x 0,1 10 PUR GY 4,4 3 x 0,25 32 x 0,1 2 PUR GY 4,4 3 x 0,25 32 x 0,1 5 PUR GY 4,4 3 x 0,25 32 x 0,1 10 PUR GY 4,4 3 x 0,25 32 x 0,1 2 PUR GY 4,4 3 x 0,25 32 x 0,1 5 PUR GY 4,4 3 x 0,25 32 x 0,1 10 PUR GY 4,4 [ mm Ø] 31 00783600.gif 00481200.gif v 4 BK Ø 8 mm e 00481200.gif 3 BU 1 BN ø 8,4 30 00481200.gif 00783700.gifw 4 BK M8 x 1 e 00783700.gif M8 x 1 1 BN 3 BU ø 9,6 00783700.gif 41,2 00783800.gifw e 23,5 00783800.gif 00783800.gif M8 x 1 4 BK M8 x 1 28 1 BN 3 BU ø 9,5 A5 – 2 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typenbezeichnung Ident-Nr. Type Ident no. Nennstrom Nennspannung Rated current Rated voltage [A] [V] Überwurfmutter Coupling nut Umgebungstemperatur Temperature range [ °C ] Stecker Leitung Connector Cable LED Schutzart Degree of protection UB SP3-2/S90 8007296 4 max. 60 -30…+90 -40…+80 IP67 SP3-5/S90 8007300 4 max. 60 -30…+90 -40…+80 IP67 SP3-10/S90 8007304 4 max. 60 -30…+90 -40…+80 IP67 KP3-2/S90 8007278 4 max. 60 -30…+90 -40…+80 IP67 KP3-5/S90 8007282 4 max. 60 -30…+90 -40…+80 IP67 KP3-10/S90 8007286 4 max. 60 -30…+90 -40…+80 IP67 SSP3-2/S90 8007350 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SSP3-5/S90 8007354 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SSP3-10/S90 8007358 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SWSP3-2/S90 8007386 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SWSP3-5/S90 8007390 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SWSP3-10/S90 8007394 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 ü A5 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A5 – 3 /0704 Steckverbinder-Systeme für Sensoren und Aktuatoren (M8 x 1 auf Ø 8 mm/M8 x 1) Connector Systems for Sensors and Actuators (M8 x 1 to Ø 8 mm/M8 x 1) Abmessungen/Bauform Anschluss Dimensions/Housing style Pin configuration [mm] v 00480900.gif 00783600.gif w M8 x 1 e ø 9,6 4 BK M8 x 1 Ø 8 mm 3 BU 1 BN Leitung/Cable Querschnitt Cross section Adernaufbau Conductor construction Länge Length Qualität Quality Farbe Colour Durchmesser Diameter [ mm2 ] [ mm Ø] [m] 3 x 0,25 32 x 0,1 1 PUR GY 4,4 3 x 0,25 32 x 0,1 1,5 PUR GY 4,4 3 x 0,25 32 x 0,1 2 PUR GY 4,4 3 x 0,25 32 x 0,1 5 PUR GY 4,4 3 x 0,25 32 x 0,1 1 PUR GY 4,4 3 x 0,25 32 x 0,1 1,5 PUR GY 4,4 3 x 0,25 32 x 0,1 2 PUR GY 4,4 3 x 0,25 32 x 0,1 5 PUR GY 4,4 3 x 0,25 32 x 0,1 1 PUR GY 4,4 3 x 0,25 32 x 0,1 1,5 PUR GY 4,4 3 x 0,25 32 x 0,1 2 PUR GY 4,4 3 x 0,25 32 x 0,1 5 PUR GY 4,4 3 x 0,25 32 x 0,1 1 PUR GY 4,4 3 x 0,25 32 x 0,1 1,5 PUR GY 4,4 3 x 0,25 32 x 0,1 2 PUR GY 4,4 3 x 0,25 32 x 0,1 5 PUR GY 4,4 [ mm Ø] ø 8,6 31 34 4 BK 1 BN v 00480900.gif 00783700.gif M8 x 1 w M8 x 1 ø 9,6 4 BK M8 x 1 M8 x 1 3 BU 3 BU 1 BN e ø 9,6 4 BK 41,2 34 1 BN v 00480900.gif 00783800.gif w M8 x 1 23,5 ø 9,6 M8 x 1 34 M8 x 1 M8 x 1 e 3 BU 4 BK 3 BU 1 BN 28 4 BK ø 9,5 1 BN 00481000.gif 00783700.gif v w M8 x 1 M8 x 1 16,5 e M8 x 1 M8 x 1 3 BU 4 BK 3 BU 1 BN ø 9,6 ø 9,5 28 41,2 4 BK 1 BN A5 – 4 /0704 3 BU Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typenbezeichnung Ident-Nr. Type Ident no. Nennspannung Rated current Rated voltage Nennstrom [A] [V] Überwurfmutter Coupling nut Umgebungstemperatur Temperature range [ °C ] Stecker Leitung Connector Cable Schutzart LED Degree of protection UB SKP3-1-SP3/S90 8015474 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SKP3-1,5-SP3/S90 8024804 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SKP3-2-SP3/S90 8015478 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SKP3-5-SP3/S90 8015479 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SKP3-1-SSP3/S90 8008683 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SKP3-1,5-SSP3/S90 8008690 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SKP3-2-SSP3/S90 8008685 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SKP3-5-SSP3/S90 8008686 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SKP3-1-SWSP3/S90 8015454 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SKP3-1,5-SWSP3/S90 8024802 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SKP3-2-SWSP3/S90 8015457 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SKP3-5-SWSP3/S90 8015460 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SWKP3-1-SSP3/S90 8015408 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SWKP3-1,5-SSP3/S90 8016217 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SWKP3-2-SSP3/S90 8015456 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 SWKP3-5-SSP3/S90 8015459 4 max. 60 CuZn - Ni -30…+90 -40…+80 IP67 ü A5 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A5 – 5 /0704 Steckverbinder-Systeme für Sensoren und Aktuatoren (Ø 8 mm/M8 x 1) Connector Systems for Sensors and Actuators (Ø 8 mm/M8 x 1) Abmessungen/Bauform Anschluss Leitung/Cable Dimensions/Housing style Pin configuration [mm] 00783600.gif w Ø 8 mm f 2 WH 4 BK 1 BN 3 BU 00783600.gif ø 8,6 00783600.gif 31 00783700.gif w M8 x 1 f M8 x 1 00783700.gif 2 WH 4 BK 1 BN 3 BU ø 9,6 00783700.gif 41,2 00783800.gif w M8 x 1 f 23,5 00783800.gif M8 x 1 00783800.gif 28 2 WH 4 BK 1 BN 3 BU Querschnitt Cross section Adernaufbau Conductor construction Länge Length Qualität Quality Farbe Colour Durchmesser Diameter [ mm2 ] [ mm Ø] [m] 4 x 0,25 32 x 0,1 5 PVC GY 4,4 4 x 0,25 32 x 0,1 5 PUR GY 4,4 4 x 0,25 32 x 0,1 10 PUR GY 4,4 4 x 0,25 32 x 0,1 2 PUR GY 4,4 4 x 0,25 32 x 0,1 5 PUR GY 4,4 4 x 0,25 32 x 0,1 10 PUR GY 4,4 4 x 0,25 32 x 0,1 2 PUR GY 4,4 4 x 0,25 32 x 0,1 5 PUR GY 4,4 4 x 0,25 32 x 0,1 10 PUR GY 4,4 [ mm Ø] ø 9,5 A5 – 6 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typenbezeichnung Ident-Nr. Type Ident no. Nennstrom Nennspannung Rated current Rated voltage [A] [V] Überwurfmutter Coupling nut Umgebungstemperatur Temperature range [ °C ] Stecker Leitung Connector Cable LED Schutzart Degree of protection UB SP4-2/S90 8007309 4 max. 30 -30…+90 -40…+80 IP67 SP4-5/S90 8007310 4 max. 30 -30…+90 -40…+80 IP67 SP4-10/S90 8007312 4 max. 30 -30…+90 -40…+80 IP67 SSP4-2/S90 8007362 4 max. 30 CuZn - Ni -30…+90 -40…+80 IP67 SSP4-5/S90 8007364 4 max. 30 CuZn - Ni -30…+90 -40…+80 IP67 SSP4-10/S90 8007366 4 max. 30 CuZn - Ni -30…+90 -40…+80 IP67 SWSP4-2/S90 8007398 4 max. 30 CuZn - Ni -30…+90 -40…+80 IP67 SWSP4-5/S90 8007400 4 max. 30 CuZn - Ni -30…+90 -40…+80 IP67 SWSP4-10/S90 8007402 4 max. 30 CuZn - Ni -30…+90 -40…+80 IP67 ü A5 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A5 – 7 /0704 Steckverbinder-Systeme für Sensoren und Aktuatoren (M12 x 1 auf Ø 8 mm/M8 x 1/M12 x 1/Ende offen) Connector Systems for Sensors and Actuators (M12 x 1 to Ø 8 mm/M8 x 1/M12 x 1/Open end) Abmessungen/Bauform Anschluss Leitung/Cable Dimensions/Housing style Pin configuration [mm] v 00460600.gif 00783600.gif w M12 x 1 e ø 15 2 M12 x 1 Ø 8 mm 1 BN 31 42 1 BN w M8 x 1 e M8 x 1 1 BN 42 1 BN 12 w f M12 x 1 ø 15 1 BN ø 10,2 ø 11,6 3 BU 2 WH 48,5 12 3 BU 12 1 BN 4 BK w 00460600.gif 00460500.gif 2 WH M12 x 1 f M12 x 1 Durchmesser Diameter [ mm2 ] [ mm Ø] [m] 3 x 0,25 32 x 0,1 1 PUR GY 4,4 3 x 0,25 32 x 0,1 1,5 PUR GY 4,4 3 x 0,25 32 x 0,1 2 PUR GY 4,4 3 x 0,25 32 x 0,1 5 PUR GY 4,4 3 x 0,25 32 x 0,1 1 PUR GY 4,4 3 x 0,25 32 x 0,1 1,5 PUR GY 4,4 3 x 0,25 32 x 0,1 2 PUR GY 4,4 3 x 0,25 32 x 0,1 5 PUR GY 4,4 4 x 0,34 43 x 0,1 5 PVC GY 5,2 4 x 0,34 43 x 0,1 2 PUR GY 5,2 4 x 0,34 43 x 0,1 5 PUR GY 5,2 4 x 0,34 43 x 0,1 2 PVC-X GY 5,2 4 x 0,34 43 x 0,1 5 PVC-X GY 5,2 4 x 0,34 43 x 0,1 2 PUR GY 5,2 4 x 0,34 43 x 0,1 5 PUR GY 5,2 4 x 0,34 43 x 0,1 2 PUR GY 5,2 4 x 0,34 43 x 0,1 5 PUR GY 5,2 [ mm Ø] 4 BK ø 15 42 ø 10,2 ø 11,6 3 BU 2 WH M12 x 1 M12 x 1 M12 x 1 Farbe Colour 3 BU 4 BK 41,2 v 00460600.gif 00460500.gif Qualität Quality 4 BK ø 9,6 ø 10,2 ø 11,6 3 BU 2 M12 x 1 - M12 x 1 ø 15 Länge/ Length 3 BU 4 BK 12 v 00460600.gif 00783700.gif Adernaufbau Conductor construction 4 BK ø 8,6 ø 10,2 ø 11,6 Querschnitt Cross section ø 15 3 BU 1 BN 4 BK 48,5 ø 10,2 ø 11,6 12 w 00460600.gif 00460500.gif M12 x 1 2 WH f 3 BU 33 1 BN 4 BK M12 x 1 ø 15 ø 8,8 ø 11,6 A5 – 8 /0704 31,5 12 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typenbezeichnung Ident-Nr. Type Ident no. Nennspannung Rated current Rated voltage Nennstrom [A] [V] Überwurfmutter Coupling nut Umgebungstemperatur Temperature range [ °C ] Stecker Leitung Connector Cable Schutzart LED Degree of protection UB WAK3-1-SP3/S90 8015483 4 max. 250 CuZn - Ni -30…+90 -40…+80 IP67 WAK3-1,5-SP3/S90 8024803 4 max. 250 CuZn - Ni -30…+90 -40…+80 IP67 WAK3-2-SP3/S90 8015484 4 max. 250 CuZn - Ni -30…+90 -40…+80 IP67 WAK3-5-SP3/S90 8015485 4 max. 250 CuZn - Ni -30…+90 -40…+80 IP67 WAK3-1-SSP3/S90 8009713 4 max. 250 CuZn - Ni -30…+90 -40…+80 IP67 WAK3-1,5-SSP3/S90 8017210 4 max. 250 CuZn - Ni -30…+90 -40…+80 IP67 WAK3-2-SSP3/S90 8010511 4 max. 250 CuZn - Ni -30…+90 -40…+80 IP67 WAK3-5-SSP3/S90 8015475 4 max. 250 CuZn - Ni -30…+90 -40…+80 IP67 WAK4-5-WAS4/P00 8006745 4 max. 250 CuZn - Ni -40…+80 -25…+80 IP67 WAK4-2-WAS4/S90 8006739 4 max. 250 CuZn - Ni -40…+80 -25…+80 IP67 WAK4-5-WAS4/S90 8006746 4 max. 250 CuZn - Ni -40…+80 -25…+80 IP67 WAK4-2-WAS4/XOR 8006740 4 max. 250 CuZn - Ni -40…+80 -25…+80 IP67 WAK4-5-WAS4/XOR 8006747 4 max. 250 CuZn - Ni -40…+80 -25…+80 IP67 WAS4-2/S90 8007098 4 max. 250 CuZn - Ni -40…+80 -25…+80 IP67 WAS4-5/S90 8007105 4 max. 250 CuZn - Ni -40…+80 -25…+80 IP67 WWAS4-2/S90 8007200 4 max. 250 CuZn - Ni -40…+80 -25…+80 IP67 WWAS4-5/S90 8007207 4 max. 250 CuZn - Ni -40…+80 -25…+80 IP67 ü A5 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A5 – 9 /0704 Steckverbinder-Systeme für Sensoren und Aktuatoren (M12 x 1) – geschirmt Connector Systems for Sensors and Actuators (M12 x 1) – shielded Abmessungen/Bauform Anschluss Leitung/Cable Dimensions/Housing style Pin configuration [mm] w 00783600.gif M12 x 1 g 00783600.gif M12 x 1 3 BU 5 shield ø 15 00783600.gif ø 10,2 ø 11,6 Länge Length Farbe Colour Durchmesser Diameter [ mm2 ] [ mm Ø] [m] 5 x 0,34 43 x 0,1 2 PUR-H GY 5,2 5 x 0,34 43 x 0,1 5 PUR-H GY 5,2 5 x 0,34 43 x 0,1 1 PUR-H GY 5,2 5 x 0,34 43 x 0,1 2 PUR-H GY 5,2 5 x 0,34 43 x 0,1 5 PUR-H GY 5,2 [ mm Ø] 4 BK 12 v M12 x 1 00783600.gif M12 x 1 00783600.gif 12 g 3 BU 5 shield ø 15 ø 15 2 WH M12 x 1M12 x 1 48,5 1 BN 4 BK 42 ø 10,2 ø 11,6 2 WH 12 1 BN 5 shield 1) 1 BN Adernaufbau Conductor construction 48,5 00783600.gif w ø 10,2 ø 11,6 2 WH Qualität1) Quality 1) Querschnitt Cross section 3 BU 4 BK PUR-H = Polyurethan, halogenfrei/Polyurethane, halogen-free A5 – 10 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typenbezeichnung Ident-Nr. Type Ident no. Nennspannung Rated current Rated voltage Nennstrom [A] [ V AC/VDC] Überwurfmutter Coupling nut Umgebungstemperatur Temperature range [ °C ] Stecker Leitung Connector Cable Schutzart LED Degree of protection UB WAS4.5-2/S57 8016985 4 30/36 -40…+80 -40…+90 IP67 WAS4.5-5/S57 8016986 4 30/36 -40…+80 -40…+90 IP67 WAS4.5-1-WAK4.5/S57 8016987 4 30/36 CuZn - Ni -40…+80 -40…+90 IP67 WAS4.5-2-WAK4.5/S57 8016988 4 30/36 CuZn - Ni -40…+80 -40…+90 IP67 WAS4.5-5-WAK4.5/S57 8016989 4 30/36 CuZn - Ni -40…+80 -40…+90 IP67 ü A5 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A5 – 11 /0704 Konfektionierbare Steckverbinder-Systeme (M8 x 1) Field wireable Connector Systems (M8 x 1) Abmessungen/Bauform Leiteranzahl Kabellänge Dimensions/Housing style Number of conductors Cable length Werkstoffe/Materials Kabelmantel Cable jacket Überwurfmutter Coupling nut Griffteil Grip [m] [mm] M8 x 1 M8 x 1 v 3 – PA GD-Zn-Ni PA 4 – PA GD-Zn-Ni PA 3 – PA GD-Zn-Ni PA 4 – PA GD-Zn-Ni PA 3 – PA GD-Zn-Ni PA 4 – PA GD-Zn-Ni PA 3 – PA GD-Zn-Ni PA 4 – PA GD-Zn-Ni PA ø 13 43,5 M8 x 1 v 41,5 25 M8 x 1 ø 13 M8 x 1 M8 x 1 w ø 13 43,5 M8 x 1 w 41,5 M8 x 1 ø 13 25 Anschlussbelegung Pin Configuration ( C015 ) ( C016 ) v v A5 – 12 /0704 ( C018 ) w w 4 4 3 ( C017 ) 1 4 2 3 1 1 3 2 4 1 3 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typenbezeichnung Ident-Nr. Nennstrom Type Ident no. Rated current Nennspannung Rated voltage [A] [ V AC/VDC ] Anschluss Connection Umgebungstemperatur/ Temperature range [ °C ] Stecker Leitung Connector Cable Schutzart LED Degree of protection UB ü H5131-0 6902700 4 60/60 ( C015 ) -40…+80 -25…+80 IP67 H5141-0 6902720 4 60/60 ( C016 ) -40…+80 -25…+80 IP67 H5231-0 6902800 4 60/60 ( C015 ) -40…+80 -25…+80 IP67 H5241-0 6902820 4 60/60 ( C016 ) -40…+80 -25…+80 IP67 HS5131-0 6902710 4 60/60 ( C017 ) -40…+80 -25…+80 IP67 HS5141-0 6902730 4 60/60 ( C018 ) -40…+80 -25…+80 IP67 HS5231-0 6902810 4 60/60 ( C017 ) -40…+80 -25…+80 IP67 HS5241-0 6902830 4 60/60 ( C018 ) -40…+80 -25…+80 IP67 A5 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A5 – 13 /0704 Konfektionierbare Steckverbinder-Systeme (M12 x 1) Field wireable Connector Systems (M12 x 1) Abmessungen/Bauform Leiteranzahl Kabellänge Dimensions/Housing style Number of conductors Cable length Werkstoffe/Materials Kabelmantel Cable jacket Überwurfmutter Coupling nut Griffteil Grip [m] [mm] M12 x 1 4 – PBT CuZn-Ni PBT 5 – PBT CuZn-Ni PBT 4 – PBT CuZn-Ni PBT 5 – PBT CuZn-Ni PBT M12 x 1 4 – PBT CuZn-Ni PBT w 5 – PBT CuZn-Ni PBT M12 x 1 4 – PBT CuZn-Ni PBT w 5 – PBT CuZn-Ni PBT v ø 20 54 M12 x 1 v ø 20 30,5 35 M12 x 1 ø 20 60 M12 x 1 ø 20 30,5 41 Anschlussbelegung Pin Configuration ( C011 ) ( C012 ) ( C020 ) v w v 2 2 2 1 3 4 A5 – 14 /0704 1 3 4 w 2 3 1 5 ( C021 ) 4 1 3 5 4 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typenbezeichnung Ident-Nr. Type Ident no. Nennspannung Rated current Rated voltage Nennstrom [A] [ V AC/VDC ] Anschluss Connection Umgebungstemperatur/ Temperature range/ [ °C ] Stecker Leitung Connector Cable Schutzart LED Degree of protection UB ü H8141-0 6902500 4 125/150 ( C011 ) -40…+80 -25…+80 IP67 B8151-0 6904601 4 30/36 ( C020 ) -40…+80 -25…+80 IP67 H8241-0 6902600 4 125/150 ( C011 ) -40…+80 -25…+80 IP67 B8251-0 6904602 4 30/36 ( C020 ) -40…+80 -25…+80 IP67 HS8141-0 6902510 4 125/150 ( C012 ) -40…+80 -25…+80 IP67 BS8151-0 6904611 4 30/36 ( C021 ) -40…+80 -25…+80 IP67 HS8241-0 6902610 4 125/150 ( C012 ) -40…+80 -25…+80 IP67 BS8251-0 6904612 4 30/36 ( C021 ) -40…+80 -25…+80 IP67 A5 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A5 – 15 /0704 Verteilersysteme – Blockverteiler/Aktuator-Sensor-Boxen Junctions – Block Junctions/Actuator-Sensor-Boxes Leitung/Cable Abmessungen/Bauform Anschluss Dimensions/Housing style Pin configuration [mm] M1200207400.gif x1 00010500.gif M12 x 1 – 18 20 M12 x 1 12,5 42 13 23 Qualität1) Quality1) Farbe Colour Querschnitt Cross section Adernaufbau Conductor construction Länge Length [ mm2 ] [ mm Ø] [ mm Ø] 4 x 0,34 43 x 0,1 2 PUR-H BK 7,9 3 x 1,0 128 x 0,1 5 PUR-H BK 8,6 Durchmesser Diameter [ mm Ø] 2 1 3 1 4 2 1 ø 4,2 25 38 3 4 M12 x 1 1 3 4 00087300.gif 00214500.gif M12 x 1 20 2 M12 x 1 – 18 M12 x 1 1 3 12,5 42 23 13 4 1 2 1 Æ 4,2 25 3 4 M12 x 1 38 1 3 4 2 01001035500.gif 01031800.gif 3 1 01035500.gif 01031800.gif 3 5 1 27 4 4 M4 x 40 DIN 912 2 60 107 36 132 16,9 7 00590602.gif 01031900.gif 5 2 8 3 6 00590602.gif 01031900.gif 1 43 x 0,1 3 x 1,0 128 x 0,1 3 1 4 M4 x 40 DIN 912 27 8 x 0,34 2 5 4 107 60 36 162 3 1 16,9 5 1) 4 PUR-H = Polyurethan, halogenfrei/Polyurethane, halogen-free A5 – 16 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typenbezeichnung Ident-Nr. Type Ident no. Anschluss Sensoren/ Aktuatoren Connection sensors/ actuators Nennstrom Rated current Nennspannung Rated voltage [A] [V] Umgebungstemperatur Temperature range [ °C ] Verteiler Leitung Junction Cable LEDs ü FSM4-2FKM3/S89 8010464 M12 x 1 4 max. 250 -30…+ 90 FSM4-2FKM3P3/S89 8012652 M12 x 1 4 10 ... 30 -30…+ 90 4MB12-5.4P2-2/S366 8018110 M12 x 1 4 / Σ 12 10…48 -30…+ 80 -40…+ 90 5 8MB12-5.4P2-5/S366 8018105 M12 x 1 4 / Σ 12 10…48 -30…+ 80 -40…+ 90 9 3 A5 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A5 – 17 /0704 Verteilersysteme – Blockverteiler/Y-Verteiler Junctions – Block Junctions/Y-Junctions Abmessungen/Bauform Anschluss Dimensions/Housing style Pin configuration Leitung/Cable Farbe Colour Querschnitt Cross section Adernaufbau Conductor construction Länge Length [ mm2 ] [ mm Ø] [ mm Ø] 4 x 0,34 43 x 0,1 0,3/0,3 PVC GY 5,2 4 x 0,34 43 x 0,1 0,6/0,6 PVC GY 5,2 4 x 0,34 43 x 0,1 1/1 PVC GY 5,2 4 x 0,34 43 x 0,1 0,3/0,3 PUR GY 5,2 4 x 0,34 43 x 0,1 0,6/0,6 PUR GY 5,2 4 x 0,34 43 x 0,1 1/1 PUR GY 5,2 4 x 0,34 43 x 0,1 0,3/0,3 PVC-I OR 5,2 00918800.gif 00231100.gif 4 x 0,34 43 x 0,1 0,6/0,6 PVC-I OR 5,2 00918800.gif 00231100.gif 4 x 0,34 43 x 0,1 1/1 PVC-I OR 5,2 [mm] 00915500.gif 00553400.gif M12 x 1 M12 x 1 – Qualität Quality Durchmesser Diameter [ mm Ø] 2 M12 x 1 1 3 12,5 4 12 5 2 M12 x 1 30 1 3 4 2 1 3 4 M12 x 1 – 2 BK (2) M12 x 1 M12 x 1 00918800.gif 00231100.gif ø 19 10 34 M12 x 1 ø 15 3 BU x2 4 BK (1) 00918800.gif 00231100.gif ø 19,2 1 2 52 00918800.gif 00231100.gif 1 BN x2 42 2 1 BN 3 BU 4 BK 00918800.gif 00231100.gif 2 00918800.gif 00231100.gif 1 BN 00918800.gif 00231100.gif 1) 3 BU 4 BK Nicht für BL67-M12-Basismodule geeignet/Not suitable for BL67 M12-base modules A5 – 18 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typenbezeichnung Ident-Nr. Type Ident no. Anschluss Sensoren/ Aktuatoren Connection sensors/ actuators Nennstrom Rated current Nennspannung Rated voltage [A] [V] Umgebungstemperatur Temperature range [ °C ] Verteiler Leitung Junction Cable LEDs ü FSM5-2FKM5.4/S55 1) 8018720 M12 x 1 4 max. 60 -30…+ 90 FSM4-2WAK3-0,3/0,3/P00 8008065 M12 x 1 4 max. 250 -30…+ 90 -40…+ 80 FSM4-2WAK3-0,6/0,6/P00 8008070 M12 x 1 4 max. 250 -30…+ 90 -40…+ 80 FSM4-2WAK3-1/1/P00 8009560 M12 x 1 4 max. 250 -30…+ 90 -40…+ 80 FSM4-2WAK3-0,3/0,3/S90 8008066 M12 x 1 4 max. 250 -30…+ 90 -40…+ 80 FSM4-2WAK3-0,6/0,6/S90 8008071 M12 x 1 4 max. 250 -30…+ 90 -40…+ 80 FSM4-2WAK3-1/1/S90 8009561 M12 x 1 4 max. 250 -30…+ 90 -40…+ 80 FSM4-2WAK3-0,3/0,3/XOR 8008067 M12 x 1 4 max. 250 -30…+ 90 -40…+ 80 FSM4-2WAK3-0,6/0,6/XOR 8008072 M12 x 1 4 max. 250 -30…+ 90 -40…+ 80 FSM4-2WAK3-1/1/XOR 8009562 M12 x 1 4 max. 250 -30…+ 90 -40…+ 80 A5 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A5 – 19 /0704 A5 – 20 /0704 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com DeviceNet™ – Verschlusskappen 7/8“ und M12 x 1 DeviceNet™ – 7/8" and M12 x 1 blanking plugs Abmessungen Anwendung Material und Farbe Typenbezeichnung Ident-Nr. Dimensions Application Material and colour Type Ident no. Staubkappe für 7/8“-Einbauflansche, Polyamid RSM-DUST-CAP 6914862 keine interne Verdrahtung, schwarz 50 Stück pro Beutel Polyamide Protective dust cap for 7/8“ black VZ 8 8018816 RSM-CC 6914829 RKM-CC 6914831 VZ 3 800004 21,8 1,5 12,7 mounting flange, no internal wiring, 50 pcs. per package 24 7/8-16UN-2A Verschraubkappe für 7/8“-Kupplungen, Polyamid keine interne Verdrahtung schwarz Screw cap for 7/8“ female connectors, Polyamide no internal wiring black Verschraubkappe für 7/8“-Kupplungen, nickelbeschichtetes keine interne Verdrahtung Messing, schwarz Screw cap for 7/8“ female connectors, nickel-plated brass, no internal wiring black Verschraubkappe für 7/8“-Stecker, nickelbeschichtetes keine interne Verdrahtung Messing, schwarz Screw cap for 7/8“ male connectors, nickel-plated brass, no internal wiring black Verschraubkappe für 12 x 1-Kupplungen, Polyurethan 7,5 13,5 » 16,3 ø 25,3 7/8-16UN 9,6 ø 25,3 7/8-16UN ø 16 M12 x 1 9 14 keine interne Verdrahtung schwarz Screw cap for M12 x 1 female Polyurethane connectors, black no internal wiring A5 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A5 – 21 /0704 Type index Typ/Type Seite/Page 4MB12-5.4P2-2/S366 8MB12-5.4P2-5/S366 B4151-0/13,5 B4151-0/9 B4251-0/9 B8151-0 B8151-0/9 B8251-0 B8251-0/9 B4148-0/9 BIC-84-E424 BMSWS 8151-8,5 BMSWS 8251-8,5 BMWS 8151-8,5 BMWS 8251-8,5 BS4151-0/13,5 BS4151-0/9 BS4251-0/9 BS8151-0 BS8151-0/9 BS8251-0 BS8251-0/9 BS4148-0/9 KABEL5711-150M KABEL5711-30M KABEL5711-500M KABEL572-150M KABEL572-30M KABEL572-500M KABEL5723-150M KABEL5723-30M KABEL5723-500M CBC5-5711-0,5M CBC5-5711-1M CBC5-5711-2M CBC5-572-0.5M CBC5-572-1M CBC5-572-2M CBC5-5723-0,5M CBC5-5723-1M CBC5-5723-2M D9-451-0,5M-0,5M D9-451-1M-1M D9-451-2M-2M D9T451-0,5M D9T451-1M D9T451-2M FDN-DN1 FDNL-CSG88-T FDNL-L0800-T FDNL-L1600-T FDNL-N0800-T FDNL-N1600-T FDNL-S0800-T FDNL-S1600-T FDNP-CPG88-TT FDNP-L0404G-TT FDNP-L0808G-TT FDNP-L0808H-TT FDNP-P0808H-TT FDNP-P1204G-TT 84 /0704 A5 – 16 A5 – 16 A3 – 13 A3 – 12/A4 – 4 A3 – 12/A4 – 4 A5 – 14 A3 – 13 A5 – 14 A3 – 13 A4 – 8 A3 – 15 A3 – 4 A3 – 4 A3 – 4 A3 – 4 A3 – 13 A3 – 12/A4 – 4 A3 – 12/A4 – 4 A5 – 1 A3 – 13 A5 – 14 A3 – 13 A4 – 8 A1 – 10 A1 – 10 A1 – 10 A1 – 8 A1 – 8 A1 – 8 A1 – 12 A1 – 12 A1 – 12 A1 – 14 A1 – 14 A1 – 14 A1 – 14 A1 – 14 A1 – 14 A1 – 14 A1 – 14 A1 – 14 A1 – 6 A1 – 6 A1 – 6 A1 – 6 A1 – 6 A1 – 6 78 59 47 48 56 58 55 57 49 50 51 54 53 52 Typ/Type FDNP-S0008G-TT FDNP-S0008H-TT FDNP-S0404G-TT FDNP-S0808G-TT FDNP-XSG16-TT FENP-S0008G FENP-S0800 FENP-S0808G FENP-S1600 FENP-XSG16 FK57 FKDW4.54-0,5 FKFDW4.54-0,5 FKM-FS57-M12 FKSD-841-0,5M FKW4.54-0,5 FKW5L FKW-FSW-45/M12 FLDP-IM16-0001 FLDP-IM32-0001 FLDP-IM8-0001 FLDP-IOM1616-0001 FLDP-IOM2012-0001 FLDP-IOM248-0001 FLDP-IOM84-0001 FLDP-IOM84-0002 FLDP-IOM88-0001 FLDP-IOM88-0002 FLDP-OM16-0001 FLDP-OM8-0001 FLDP-OM8-0002 FS57 FSDP-IM16-0001 FSDP-IOM84-0001 FSDW4.54-0,5 FSFDW4.54-0,5 FSM-2FKM-57 FSM4-2FKM3/S89 FSM4-2FKM3P3/S89 FSM4-2WAK3-0,3/0,3/P00 FSM4-2WAK3-0,3/0,3/S90 FSM4-2WAK3-0,3/0,3/XOR FSM4-2WAK3-0,6/0,6/P00 FSM4-2WAK3-0,6/0,6/S90 FSM4-2WAK3-0,6/0,6/XOR FSM4-2WAK3-1/1/P00 FSM4-2WAK3-1/1/S90 FSM4-2WAK3-1/1/XOR FSM5-2FKM5.4/S55 FSSD-841-0,5M FSW4.54-0,5 FSW5L FXDP-CSG88-0001 FXDP-IM16-0001 FXDP-IM8-0001 FXDP-IOM88-0001 FXDP-OM16-0001 FXDP-OM8-0001 FXDP-XSG16-0001 H5131-0 H5141-0 Seite/Page 63 64 60 61 62 71 69 72 70 73 A3 – 14 A3 – 5 A3 – 5 A3 – 15 A1 – 16 A3 – 5 A3 – 5 A3 – 7 26 27 25 35 37 36 33 34 31 32 30 28 29 A3 – 14 41 42 A3 – 6 A3 – 6 A3 – 8 A5 – 16 A5 – 16 A5 – 18 A5 – 18 A5 – 18 A5 – 18 A5 – 18 A5 – 18 A5 – 18 A5 – 18 A5 – 18 A5 – 18 A1 – 16 A3 – 6 A3 – 6 20 16 15 19 18 17 21 A5 – 12 A5 – 12 Typ/Type H5231-0 H5241-0 H8141-0 H8241-0 HS5131-0 HS5141-0 HS5231-0 HS5241-0 HS8141-0 HS8241-0 IPSKP4-0,15-SSP4/S90 IPSKP4-0,5-SSP4/S90 IPSKP4-10/S90 IPSKP4-1-SSP4/S90 IPSKP4-2/S90 IPSKP4-2-SSP4/S90 IPSKP4-5/S90 IPSKP4-5-SSP4/S90 IPSWKP4-0,15-SWSP4/S90 IPSWKP4-0,5-SWSP4/S90 IPSWKP4-10/S90 IPSWKP4-1-SWSP4/S90 IPSWKP4-2/S90 IPSWKP4-2-SWSP4/S90 IPSWKP4-5/S90 IPSWKP4-5-SWSP4/S90 JTBS57-E434 JTBS57-E634 JTBS57-M434 JTBS57-M634 KABEL451-150M KABEL451-30M KABEL451-500M KABEL-DN-43-150M KABEL-DN-43-30M KABEL-DN-43-500M KABEL-PDP-52-150M KABEL-PDP-52-30M KABEL-PDP-52-500M KP3-10/S90 KP3-2/S90 KP3-5/S90 PDP-TRA REP-DN REP-DP-0002 RJ45S-841-6M RJ45S-841-10M RJ45S-843-15M RJ45S-FKSD-841-0,5M RJ45S-FSSD-841-0,5M RJ45S-RJ45S-841-0,5M RJ45S-RJ45S-841-1M RJ45S-RJ45S-841-2M RJ45S-RJ45S-841-4M RJ45S-RJ45S-841-6M RJ45S-RJ45S-841-10M RJ45S-RJ45S-843-15M RJ45S-RJ45S-843-30M RKC572-10M RKC572-15M RKC572-6M Seite/Page A5 – 12 A5 – 12 A5 – 14 A5 – 14 A5 – 12 A5 – 12 A5 – 12 A5 – 12 A5 – 14 A5 – 14 A2 – 6 A2 – 6 A2 – 6 A2 – 6 A2 – 6 A2 – 6 A2 – 6 A2 – 6 A2 – 6 A2 – 6 A2 – 6 A2 – 6 A2 – 6 A2 – 6 A2 – 6 A2 – 6 A3 – 11 A3 – 11 A3 – 11 A3 – 11 A1 – 4 A1 – 4 A1 – 4 A2 – 4 A2 – 4 A2 – 4 A2 – 2 A2 – 2 A2 – 2 A5 – 2 A5 – 2 A5 – 2 A3 – 3 76 74 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 8 A1 – 8 A1 – 8 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typ/Type Seite/Page RKC-CBC5-572-0.5M A1 – 14 RKC-CBC5-572-1M A1 – 14 RKC-CBC5-572-2M A1 – 14 RKE57-TR2 A3 – 10 RKF57 A3 – 14, A4 – 5 RKFL46 A4 – 9 RKM5711-10M A1 – 10 RKM5711-15M A1 – 10 RKM5711-6M A1 – 10 RKM5723-10M A1 – 12 RKM5723-15M A1 – 12 RKM5723-6M A1 – 12 RKM-CBC5-5711-0.5M A1 – 14 RKM-CBC5-5711-1M A1 – 14 RKM-CBC5-5711-2M A1 – 14 RKM-CBC5-5723-0.5M A1 – 14 RKM-CBC5-5723-1M A1 – 14 RKM-CBC5-5723-2M A1 – 14 RKM40-RKM40-L-RSM40 A4 – 7 RKM43-0,3-RSM43 A2 – 4 RKM43-0,5-RSM43 A2 – 4 RKM43-10M A2 – 4 RKM43-10-RSM43 A2 – 4 RKM43-15M A2 – 4 RKM43-15-RSM43 A2 – 4 RKM43-1-RSM43 A2 – 4 RKM43-2-RSM43 A2 – 4 RKM43-4-RSM43 A2 – 4 RKM43-6M A2 – 4 RKM43-6-RSM43 A2 – 4 RKM52-0,3-RSM52 A2 – 2 RKM52-0,5-RSM52 A2 – 2 RKM52-10M A2 – 2 RKM52-10-RSM52 A2 – 2 RKM52-15M A2 – 2 RKM52-15-RSM52 A2 – 2 RKM52-1-RSM52 A2 – 2 RKM52-2-RSM52 A2 – 2 RKM52-30-RSM52 A2 – 2 RKM52-4-RSM52 A2 – 2 RKM52-6M A2 – 2 RKM52-6-RSM52 A2 – 2 RKM57-TR2 A3 – 10 RKM-CC A5 – 21 RKS-841-6M A1 – 16 RKS-841-10M A1 – 16 RKS-843-15M A1 – 16 RKS-RJ45S-841-0,5M A1 – 16 RKSW-2RSSW45-0001 A3 – 2 RKSW451-10M A1 – 4 RKSW451-15M A1 – 4 RKSW451-6M A1 – 4 RKSW-D9-RKSW-451-0,3M-0,3M A1 – 6 RKSW-D9-RKSW-451-0,5M-0,5M A1 – 6 RKSW-D9-RKSW-451-1M-1M A1 – 6 RKSW-D9-RKSW-451-2M-2M A1 – 6 RKSW-D9T451-0,3M A1 – 6 RKSW-D9T451-0,5M A1 – 6 RKSW-D9T451-1M A1 – 6 RKSW-D9T451-2M A1 – 6 RKSWS4.5[5]-2RSSWS A3 – 2 Typ/Type RSC572-10M RSC572-15M RSC572-6M RSC-CBC5-572-0.5M RSC-CBC5-572-1M RSC-CBC5-572-2M RSC-RKC572-0.3M RSC-RKC572-0.5M RSC-RKC572-10M RSC-RKC572-15M RSC-RKC572-1M RSC-RKC572-2M RSC-RKC572-30M RSC-RKC572-4M RSC-RKC572-6M RSE57-TR2 RSF57 RSF-RKF-40/22 RSF-RKF-57/22 RSFL46 RSM5711-10M RSM5711-15M RSM5711-6M RSM5723-10M RSM5723-15M RSM5723-6M RSM-CBC5-5711-0.5M RSM-CBC5-5711-1M RSM-CBC5-5711-2M RSM-CBC5-5723-0.5M RSM-CBC5-5723-1M RSM-CBC5-5723-2M RSM-CC RSM-DUST-CAP RSM-RKM5711-0.3M RSM-RKM5711-0.5M RSM-RKM5711-1M RSM-RKM5711-2M RSM-RKM5711-4M RSM-RKM5711- 6M RSM-RKM5711-10M RSM-RKM5711-15M RSM-RKM5711-30M RSM-RKM5723-0.3M RSM-RKM5723-0.5M RSM-RKM5723-10M RSM-RKM5723-15M RSM-RKM5723-1M RSM-RKM5723-2M RSM-RKM5723-30M RSM-RKM5723-4M RSM-RKM5723-6M RSM-2RKM40 RSM-2RKM50 RSM-2RKM57 RSM43-10M RSM43-15M RSM43-6M RSM52-10M RSM52-15M RSM52-6M Seite/Page A1 – 8 A1 – 8 A1 – 8 A1 – 14 A1 – 14 A1 – 14 A1 – 8 A1 – 8 A1 – 8 A1 – 8 A1 – 8 A1 – 8 A1 – 8 A1 – 8 A1 – 8 A3 – 10 A3 – 14, A4 – 5 A4 – 9 A3 – 15, A4 – 5 A4 – 9 A1 – 10 A1 – 10 A1 – 10 A1 – 12 A1 – 12 A1 – 12 A1 – 14 A1 – 14 A1 – 14 A1 – 14 A1 – 14 A1 – 14 A5 – 21 A5 – 21 A1 – 10 A1 – 10 A1 – 10 A1 – 10 A1 – 10 A1 – 10 A1 – 10 A1 – 10 A1 – 10 A1 – 12 A1 – 12 A1 – 12 A1 – 12 A1 – 12 A1 – 12 A1 – 12 A1 – 12 A1 – 12 A4 – 7 A4 – 3 A3 – 8 A2 – 4 A2 – 4 A2 – 4 A2 – 2 A2 – 2 A2 – 2 Typ/Type Seite/Page RSM57-TR2 RSM-DUST-CAP RSM-FKM-RKM57 RSS4.5-PDP-TR RSS-841-6M RSS-841-10M RSS-843-15M RSS-FKSD-841-0,5M RSS-FSSD-841-0,5M RSS-RJ45S-841-0,5M RSS-RSS-841-0,5M RSS-RSS-841-1M RSS-RSS-841-2M RSS-RSS-841-4M RSS-RSS-841-6M RSS-RSS-841-10M RSS-RSS-843-15M RSS-RSS-843-30M RSSW451-10M RSSW451-15M RSSW451-6M RSSW-D9-RKSW-451-0,3M-0,3M RSSW-D9-RKSW-451-0,5M-0,5M RSSW-D9-RKSW-451-1M-1M RSSW-D9-RKSW-451-2M-2M RSSW-D9T451-0,3M RSSW-D9T451-0,5M RSSW-D9T451-1M RSSW-D9T451-2M RSSW-RKSW451-0,3M RSSW-RKSW451-0,5M RSSW-RKSW451-10M RSSW-RKSW451-15M RSSW-RKSW451-1M RSSW-RKSW451-2M RSSW-RKSW451-30M RSSW-RKSW451-4M RSSW-RKSW451-6M SE-84X-E524 SE-84X-E924 SKP3-1,5-SP3/S90 SKP3-1,5-SSP3/S90 SKP3-1,5-SWSP3/S90 SKP3-1-SP3/S90 SKP3-1-SSP3/S90 SKP3-1-SWSP3/S90 SKP3-2-SP3/S90 SKP3-2-SSP3/S90 SKP3-2-SWSP3/S90 SKP3-5-SP3/S90 SKP3-5-SSP3/S90 SKP3-5-SWSP3/S90 SP3-10/S90 SP3-2/S90 SP3-5/S90 SP4-10/S90 SP4-2/S90 SP4-5/S90 SSP3-10/S90 SSP3-2/S90 SSP3-5/S90 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com A3 – 10 A5 – 21 A3 – 8 A3 – 3 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 16 A1 – 4 A1 – 4 A1 – 4 A1 – 6 A1 – 6 A1 – 6 A1 – 6 A1 – 6 A1 – 6 A1 – 6 A1 – 6 A1 – 4 A1 – 4 A1 – 4 A1 – 4 A1 – 4 A1 – 4 A1 – 4 A1 – 4 A1 – 4 80, 81 80, 82 A5 – 4 A5 – 4 A5 – 4 A5 – 4 A5 – 4 A5 – 4 A5 – 4 A5 – 4 A5 – 4 A5 – 4 A5 – 4 A5 – 4 A5 – 2 A5 – 2 A5 – 2 A5 – 6 A5 – 6 A5 – 6 A5 – 2 A5 – 2 A5 – 2 85 /0704 Type index Typ/Type Seite/Page SSP4-10/S90 SSP4-2/S90 SSP4-5/S90 SWKP3-1,5-SSP3/S90 SWKP3-1-SSP3/S90 SWKP3-2-SSP3/S90 SWKP3-5-SSP3/S90 SWSP3-10/S90 SWSP3-2/S90 SWSP3-5/S90 SWSP4-10/S90 SWSP4-2/S90 SWSP4-5/S90 VB2-FKM/FKM/RSC572-1M VB2-FKM/RKC-RSC5720,5M/0,5M VB2-FKM-FKM-FSM57 VB2-FSW-FKW-FSW45 VB2-RKC572-1M-FKM-FSM VZ 3 VZ 8 WAK3-1,5-SP3/S90 WAK3-1,5-SSP3/S90 WAK3-1-SP3/S90 WAK3-1-SSP3/S90 WAK3-2-SP3/S90 WAK3-2-SSP3/S90 WAK3-5-SP3/S90 WAK3-5-SSP3/S90 WAK4-2-WAS4/S90 WAK4-5-WAS4/S90 WAK4-5-WAS4/P00 WAK4-2-WAS4/XOR WAK4-5-WAS4/XOR WAK4.5-1-WAS4.5/S57 WAK4.5-2-WAS4.5/S57 WAK4.5-5-WAS4.5/S57 WAS4.5-2/S57 WAS4.5-5/S57 WKC572-6M WKC572-10M WKC572-15M WKM5711-10M WKM5711-15M WKM5711-6M WKM5723-10M WKM5723-15M WKM5723-6M WKM43-0,3-WSM43 WKM43-0,5-WSM43 WKM43-10M WKM43-10-WSM43 WKM43-15M WKM43-15-WSM43 WKM43-1-WSM43 WKM43-2-WSM43 WKM43-4-WSM43 WKM43-6M WKM43-6-WSM43 WKM52-0,3-WSM52 WKM52-0,5-WSM52 86 /0704 A5 – 6 A5 – 6 A5 – 6 A5 – 4 A5 – 4 A5 – 4 A5 – 4 A5 – 2 A5 – 2 A5 – 2 A5 – 6 A5 – 6 A5 – 6 A3 – 9 A3 – 9 A3 – 9 A3 – 2 A3 – 9 A5 – 21 A5 – 21 A5 – 8 A5 – 8 A5 – 8 A5 – 8 A5 – 8 A5 – 8 A5 – 8 A5 – 8 A5 – 8 A5 – 8 A5 – 8 A5 – 8 A5 – 8 A5 – 10 A5 – 10 A5 – 10 A5 – 10 A5 – 10 A1 – 8 A1 – 8 A1 – 8 A1 – 10 A1 – 10 A1 – 10 A1 – 12 A1 – 12 A1 – 12 A2 – 4 A2 – 4 A2 – 4 A2 – 4 A2 – 4 A2 – 4 A2 – 4 A2 – 4 A2 – 4 A2 – 4 A2 – 4 A2 – 2 A2 – 2 Typ/Type WKM52-10M WKM52-10-WSM52 WKM52-15M WKM52-15-WSM52 WKM52-1-WSM52 WKM52-2-WSM52 WKM52-30-WSM52 WKM52-4-WSM52 WKM52-6M WKM52-6-WSM52 WKSW451-10M WKSW451-15M WKSW451-6M WSC572-10M WSC572-15M WSC572-6M WSC-WKC572- 0.3M WSC-WKC572- 0.5M WSC-WKC572-10M WSC-WKC572-15M WSC-WKC572-1M WSC-WKC572-2M WSC-WKC572-30M WSC-WKC572-4M WSC-WKC572-6M WSM5711- 6M WSM5711-10M WSM5711-15M WSM5723-10M WSM5723-15M WSM5723-6M WSM-WKM5711-0.3M WSM-WKM5711-0.5M WSM-WKM5711-1M WSM-WKM5711-2M WSM-WKM5711-4M WSM-WKM5711-6M WSM-WKM5711-10M WSM-WKM5711-15M WSM-WKM5711-30M WSM-WKM5723-0.3 M WSM-WKM5723-0.5 M WSM-WKM5723-10M WSM-WKM5723-15M WSM-WKM5723-1M WSM-WKM5723-2M WSM-WKM5723-30M WSM-WKM5723-4M WSM-WKM5723-6M WSM43-10M WSM43-15M WSM43-6M WSM52-10M WSM52-15M WSM52-6M WSSW451-10M WSSW451-15M WSSW451-6M WSSW-WKSW451-0,3M WSSW-WKSW451-0,5M WSSW-WKSW451-10M Seite/Page A2 – 2 A2 – 2 A2 – 2 A2 – 2 A2 – 2 A2 – 2 A2 – 2 A2 – 2 A2 – 2 A2 – 2 A1 – 4 A1 – 4 A1 – 4 A1 – 8 A1 – 8 A1 – 8 A1 – 8 A1 – 8 A1 – 8 A1 – 8 A1 – 8 A1 – 8 A1 – 8 A1 – 8 A1 – 8 A1 – 10 A1 – 10 A1 – 10 A1 – 12 A1 – 12 A1 – 12 A1 – 10 A1 – 10 A1 – 10 A1 – 10 A1 – 10 A1 – 10 A1 – 10 A1 – 10 A1 – 10 A1 – 12 A1 – 12 A1 – 12 A1 – 12 A1 – 12 A1 – 12 A1 – 12 A1 – 12 A1 – 12 A2 – 4 A2 – 4 A2 – 4 A2 – 2 A2 – 2 A2 – 2 A1 – 4 A1 – 4 A1 – 4 A1 – 4 A1 – 4 A1 – 4 Typ/Type WSSW-WKSW451-15M WSSW-WKSW451-1M WSSW-WKSW451-2M WSSW-WKSW451-30M WSSW-WKSW451-4M WSSW-WKSW451-6M Seite/Page A1 – 4 A1 – 4 A1 – 4 A1 – 4 A1 – 4 A1 – 4 Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Typ/Type Seite/Page Typ/Type Seite/Page Typ/Type Hans Turck GmbH & Co.KG • D–45466 Mülheim/Ruhr • Tel. 0208/4952-0 • Fax 0208/4952-264 • E-Mail: [email protected] • www.turck.com Seite/Page 87 /0704 TURCK WORLD-WIDE HEADQUARTERS ITALY TURCK BANNER S. R. L. Via Adamello, 9 20010 Bareggio (MI) Phone (+39) (02) 90364291 Fax (+39) (02) 90364838 E-Mail [email protected] BRAZIL TURCK Ltda. Rua Apucarana 134 83324-040 Pinhais Phone (+55) (41) 6682053 Fax (+55) (41) 6681794 E-Mail [email protected] KOREA TURCK Korea Branch Office Room No 406, Gyeonggi Technopark 1271-11, Sa 1-Dong, Sangnok-Gu, Ansan, Gyeonggi-Do, Korea, 426-901 Phone (+82) (31) 5 00 45 55 Fax (+82) (31) 5 00 45 58 E-Mail [email protected] CZECH REPUBLIC TURCK s.r.o. Hradecká 1151 500 03 Hradec Králové 3 Phone (+ 420) (49) 5 51 87 66 Fax (+ 420) (49) 5 51 87 67 E-Mail [email protected] THE NETHERLANDS TURCK B. V. Postbus 297 8000 AG Zwolle Phone (+31) (38) 4227750 Fax (+31) (38) 4227451 E-Mail [email protected] PR OF CHINA TURCK (Tianjin) Sensor Co. Ltd. 40, Yibin Road/Nankai District 300113 Tianjin Phone (+86) (22) 27623140 Fax (+86) (22) 27614650 E-Mail [email protected] POLAND TURCK sp.z o.o ul. Kepska 2 45-129 Opole Phone (+48) (77) 4434800 Fax (+48) (77) 4434801 E-Mail [email protected] EASTERN EUROPE / ASIA Hans Turck GmbH & Co. KG Am Bockwald 2 08340 Beierfeld Phone (+49) (3774) 1 35-0 Fax (+49) (3774) 1 35-2 22 ROMANIA TURCK Automation Romania SRL Str. luliu Tetrat nr. 18 Sector 1 011914 Bukarest Phone (+40) (21) 2 30 02 79 2 30 05 94 Fax (+40) (21) 2 31 40 87 E-Mail: [email protected] FRANCE TURCK BANNER S.A.S 3, Rue de Courtalin Magny-Le-Hongre 77703 Marne-La-Vallee Cedex 4 Phone (+33) (1) 60436070 Fax (+33) (1) 60431018 E-Mail [email protected] GREAT BRITAIN TURCK BANNER LIMITED Blenheim House Hurricane Way Wickford, Essex SS11 8YT Phone (+44) (1268) 578888 Fax (+44) (1268) 763648 E-Mail [email protected] HUNGARY TURCK Hungary kft. Könyves Kalman Krt.76 1087. Budapest Phone (+36) (1) 4770740 Fax (+36) (1) 4770741 E-Mail [email protected] www.turck.com RUSSIA TURCK Avtomatizazija O.O.O Volokolamskoe Shosse 1 office 606 a 125080 Moskau Phone (+7) (095) 1 05 00 54 Fax (+7) (095) 1 58 95 72 E-Mail [email protected] USA TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441-2656 Phone (+1) (763) 553-9224 553-7300 Fax (+1) (763) 553-0708 E-Mail [email protected] D300774 0704 FIELDBUS TECHNOLOGY BELGIUM Multiprox N. V. P. B. 71 Lion d’Orweg 12 9300 Aalst Phone (+32) (53) 766566 Fax (+32) (53) 783977 E-Mail [email protected] COMPACT FIELDBUS STATIONS IN IP67 GERMANY Hans Turck GmbH & Co. KG Witzlebenstraße 7 45472 Mülheim an der Ruhr P. O. Box 45466 Mülheim an der Ruhr Phone (+49) (208) 4952-0 Fax (+49) (208) 4952-2 64 E-Mail [email protected] ... and more than 60 representatives and agencies world-wide. Subject to change without notice F774/01 F774/01 *D300774ßß0704*