Transcript
151
COMPONENTS FOR SANITARY SYSTEM
M
N O
components for sanitary system
sanitary manifold
152
Single manifold 805ME
A
Modular manifold made of brass CW617N. Connection through lateral female and male thread with counternut and O-ring for self-sealing connection of multiple manifolds, zones G 3/4" Eurocone., 50 mm distance.
Article number 805M1TME2X 805M1TME3X 805M1TME4X
Size 1" 1" 1"
Outlet 2 - 3/4" 3 - 3/4" 4 - 3/4"
Unit 10 10 10
Single manifold E807M Single modular brass CW617N manifold. Side outlet connections: 1/2" M. Male/Female head connections: 3/4".
Article number E807M-MF-T2 E807M-MF-T3 E807M-MF-T4
Size 3/4" MF 3/4" MF 3/4" MF
Outlet 2 - 1/2" M 3 - 1/2" M 4 - 1/2" M
Center Distance 35 mm 35 mm 35 mm
Unit 10 10 10
SaniDuct potable water installation manifold With straight-way valves. Made of high-quality brass MS 63, dezincification resistant. Distributor pipe G 1.1/4" / DN 32, lateral connection 1.1/2" male thread / coupling nut, end cap. Zones G 1" male thread DN 20. Shut-off valves integrated into manifold pipe. Modular design of the manifold segments with 1, 2, 3 or 4 zones. Installation directly to pressure reducing regulator or water filter. State-of-the-art draining of the zones at the lowest point. Mounted on sound-insulated and galvanized DIN 4109 consoles. Low instalaltion depth, no dead storage in the flow, flat sealing connections, 100% pressure-tested. Max. operating temperature: 60ºC, nominal pressure PN 16. Approvals: DVGW, SVGW. Article number 3499710 3499715
Type Complete-manifold Complete-manifold
Outlet 3 4
Screw connection 1.1/2" M x 1.1/4" F 1.1/2" M x 1.1/4" F
Unit 1 1
SaniDuct extension module For SaniDuct sanitary manifold, without end cap and wall bracket.
M
N
Article number 3499700 3499705
Type Add-on-module Add-on-module
Outlet 1 2
Screw connection no no
Unit 1 1
components for sanitary system
sanitary manifold
SaniDuct dripping water gully
153
Lenght 380 mm, for SaniDuct with up to 4 zones.
Article number 3499720
Type Drip water gully
Outlet
Screw connection
Unit 1
Sanitary manifold Made of brass, connection with male thread, zones with male thread, with blind caps. Dimension between axes: 1" = 90 mm, 1.1/4" = 100 mm, 2" = 130 mm. Article number 3160053 3160054 3160055 3160056 3160062 3160063 3160064 3160065 3160066 3160084 3160085 3160086 3160087
Type SAV 3 SAV 4 SAV 5 SAV 6 SAV 2 SAV 3 SAV 4 SAV 5 SAV 6 SAV 4 SAV 5 SAV 6 SAV 7
-
Outlet 3 1/2" 4 1/2" 5 1/2" 6 1/2" 2 3/4" 3 3/4" 4 3/4" 5 3/4" 6 3/4" 4 1" 5 1" 6 1" 7 1"
1" 1" 1" 1" 1.1/4" 1.1/4" 1.1/4" 1.1/4" 1.1/4" 2" 2" 2" 2"
Unit 1 1 1 1 1 1 1 1 1 1 1 1 1
SAV step valve Made of brass, bilaterally flat-sealing 1" male connection thread, connection nipple G 3/4" Eurocone, 50 mm distance, pressure-tested, packed in a box. Optional end cap 1" for unilateral closure. Article number 3499742 3499743 3499744 3499745 3499746 3499732 3499733 3499734 3499735 3499736
Type SAV-Etage SAV-Etage SAV-Etage SAV-Etage SAV-Etage SAV-Etage SAV-Etage SAV-Etage SAV-Etage SAV-Etage
2 3 4 5 6 2 3 4 5 6
-
1" 1" 1" 1" 1" 1" 1" 1" 1" 1"
with with with with with
cap cap cap cap cap
Outlet 2 3/4" 3 3/4" 4 3/4" 5 3/4" 6 3/4" 2 3/4" 3 3/4" 4 3/4" 5 3/4" 6 3/4"
Unit 1 1 1 1 1 1 1 1 1 1
M
N O
components for sanitary system
sanitary manifold
154
A
Thread screw male thread Set includes 1 coupling nut, 1 threaded nozzle and 1 seal. For fitting with flat sealing male thread.
Article number 2160610 2160615 2160620
Type DN 15 - R 1/2" - 1" coupling nut DN 20 - R 3/4" - 1" coupling nut DN 25 - R 1" - 1" coupling nut
Unit 1 1 1
Brazed union Set includes 1 coupling nut, 1 brazed nozzle and 1 seal. For fittings with flat sealing male thread.
Article number 2160640 2160587 2160595 2160660
Type DN 12 DN 15 DN 20 DN 25
-
15 18 22 28
mm mm mm mm
-
1" 1" 1" 1"
coupling coupling coupling coupling
nut nut nut nut
Unit 1 1 1 1
ball valve for sanitary application
Ball valve Ball valve with combined feed cock and drain valve for potable water. Approved by the DVGW. 1/2", PN 10, self-sealing through O-ring, straight-way passage, with cap. Hot-pressed brass CW617N.
Article number 3230145 3499665
M
N
Type 3/4" coupling nut x 3/4" Eurocone 1/2" M x 3/4" Eurocone
Unit 25 25
components for sanitary system
pressure reducing valve
Mini water pressure reducing valve 560 / H560
155
Serie 560 Mini water pressure reducing valve are designed to reduce incoming water pressure to a sensible level to protect plumbing system components and reduce water consumption. This series is ideal where a small economical package is required such as on special industrial process applications, miscellaneous plumbing applications and OEM equipment. Series 560 are suitable for water supply pressures up to 300 psi (12 bar). Temperature range: 6 - 60ºC. 560 - female threaded inlet x female threaded outlet, H560 - female hose connection inlet x male hose connection outlet for grid systems. Article number On request
Type Mini water pressure reducing valve serie 560 / H560
Unit 1
Mini water pressure regulator P50 / P60 Serie P50 Miniature water pressure regulator are ideal for applications where a small economical package is required. This series is also suitable for deionized water. Series P60 features a balanced piston design for applications where a constant downstream and accurate flow performance is required. Max. operating pressure: 300 psi ( 21,09 bar). Temperature range: 5 - 60ºC.
Article number On request
Type Mini water pressure regulator serie P50 / P60
Unit 1
Pressure reducing valve DRV Diapraghm pressure reducing valve with compensated seat and complete with unions. Brass CW617N body and cap. Stainless steel strainer. 1/2"-3/4"-1" = 600 µ. 1.1/4"-1.1/2"-2" = 750 µ. Plastic valve seat. Interchangeable filter-regulator unit. Max. inlet pressure: 25 bar. Adjustable downstream pressure: 1,5 - 6 bar. Can be used for water, air and neutral gases up to 70°C. Pressure drops less than 1,3 bar at characteristic flow rate DIN. Noise < 20 dB. According to DVGW, SVGW, TIN, NF (only for DN 1/2" and 3/4"). Article number 0501115 0501120 0501125 0501132 0501140 0501150
Size 1/2" M 3/4" M 1" M 1.1/4" M 1.1/2" M 2" M
Unit 10 10 10 1 1 1
Pressure reducing valve DRV / M Diapraghm pressure reducing valve with compensated seat and complete with unions. With pressure gauge M1-ABS50 (scale 0-6 bar). Brass CW617N body and cap. Stainless steel strainer. 1/2"-3/4"-1" = 600 µ. 1.1/4"-1.1/2"-2" = 750 µ. Plastic valve seat. Interchangeable filterregulator unit. Max. inlet pressure: 25 bar. Adjustable downstream pressure: 1,5 - 6 bar. Can be used for water, air and neutral gases up to 70°C. Pressure drops less than 1,3 bar at characteristic flow rate DIN. Noise < 20 dB. According to DVGW, SVGW, TIN, NF (only for DN 1/2" and 3/4"). Article number 0501315 0501320 0501325 0501332 0501340 0501350
Size 1/2" M 3/4" M 1" M 1.1/4" M 1.1/2" M 2" M
Unit 10 10 10 1 1 1
M
N O
components for sanitary system
pressure reducing valve
156
Thread screw union R / DRV Spare unions complete with nut and seals for pressure reducing valves series DRV.
A
Article number 0599001 0599002 0599003 0599004 0599005 0599006
Size 1/2" M 3/4" M 1" M 1.1/4" M 1.1/2" M 2" M
Unit 1 1 1 1 1 1
Spare diaphragm MDRV Spare diaphragm for pressure reducing valves series DRV. Article number 0599007 0599008 0599009 0599010 0599011 0599012
Size 1/2" M 3/4" M 1" M 1.1/4" M 1.1/2" M 2" M
Unit 1 1 1 1 1 1
Spare regulator unit GRDRV Spare regulator unit complete with cartridge, diaphragm and O-ring for pressure reducing valves series DRV. Article number 0599025 0599026 0599027 0599028 0599029 0599030
Size 1/2" M 3/4" M 1" M 1.1/4" M 1.1/2" M 2" M
Unit 1 1 1 1 1 1
Pressure reducing valve DRV / N Patented diaphragm pressure reducing valve with compensated seat, outlet pressure adjusting knob and external graduated scale for easy reading of set pressure. Complete with unions. Body and cap of shot-blasted stamped brass CW617N. Stainless steel filter cartridge. Pressure gauge connection on both sides: 1/4". Materials in contact with fluids KTW certified. Max. inlet pressure: 25 bar. Adjustable downstream pressure: 1,5 and 6 bar. Max. operating temperature: 70°C. Can be used for water, air and neutral gases. Noise < 20dB. According to DVGW.
M
N
Article number 0502515 0502520 0502525 0502532 0502540 0502550
Size 1/2" M 3/4" M 1" M 1.1/4" M 1.1/2" M 2" M
Unit 20 20 12 1 1 1
components for sanitary system
pressure reducing valve
Pressure reducing valve DRV / MN
157
Patented diaphragm pressure reducing valve with compensated seat, outlet pressure adjusting knob and external graduated scale for easy reading of set pressure. With pressure gauge M3A-ABS50 (scale 0-6 bar). Complete with unions. Body and cap of shot-blasted stamped brass CW617N. Stainless steel filter cartridge. Pressure gauge connection on both sides: 1/4". Materials in contact with fluids KTW certified. Max. inlet pressure: 25 bar. Adjustable downstream pressure: 1,5 and 6 bar. Max. operating temperature: 70°C. Can be used for water, air and neutral gases. Noise < 20dB. According to DVGW. Article number 0502615 0502620 0502625 0502632 0502640 0502650
Size 1/2" M 3/4" M 1" M 1.1/4" M 1.1/2" M 2" M
Unit 10 10 10 1 1 1
Pressure reducing valve DRV / E Single seated pressure reducing valves with female connections. Brass CW617N body. High impact plastic cap. Max. inlet pressure: 25 bar. Adjustable downstream pressure: 1,5-6 bar. Diapraghm pressure reducing valve, compact design. Brass CW617N body. Max. upstream pressure: 25 bar. Adjustable downstream pressure: 1,5-6 bar. Max. fluid temperature: 70°C.
Article number 0502015 0502020
Size 1/2" F 3/4" F
Unit 1 1
Pressure reducing valve DRV / ED Diaphragm pressure reducing valve, compact design. Brass CW602N body (anti-dezincification alloy), with male connections complete with swivel nut: Pipe dia. 15 and 22. Gauge connection 1/4". Max. upstream pressure: 25 bar. Adjustable downstream pressure: 1.5 - 6 bar. Max. fluid temperature: 70°C. Can be used for water, compressed air. WRAS approved.
Article number 0502115 0502120
Size 15 22
Unit 10 10
Pressure reducing valve REDUFIX Diaphragm pressure reducing valve, designed for protecting electrical heating appliances or appliance for domestic hot water production. Anti-dezincification (anti-corrosion) brass body, especially suitable for single users. Gauge connection: 1/4" female. Can be installed in all positions. Max. upstream pressure: 15 bar. Max. temperature: 70°C. Article number On request On request On request
Dimension 1/2"F 3/4"MF 3/4"M
Unit 10 10 10
M
N O
components for sanitary system
pressure reducing valve
158
A
Pressure reducing valve U5B Diaphragm pressure reducing valve. Watts U.S. Patent No 3. 115. 154. Heavy duty bronze series, with large built-in filter and separate connection for quick maintenance. Internal bypass for upstream discharge of any downstream overpressures. Bronze body, cast iron cap. Stainless steel filter and seat. Diaphragm made of Nordel reinforced with nylon fibres. Max. inlet pressure: 20 bar. Adjustable downstream pressure: 1,5-5 bar. Can be used for water, air and neutral gases up to 80°C. According to ASSE, ANSI, CSA, UPC. Article number 452015000 452020000 452025000 452032000 452040000 452050000
Size 1/2" F 3/4" F 1" F 1.1/4" F 1.1/2" F 2" F
Unit 1 1 1 1 1 1
Pressure reducing valve PRECISIO Bracketed diaphragm pressure reducing valve; complete with 2 pressure gauge connections 1/4" F. Reduces the pressure without lowering the flow rate. Rugged and reliable unit not requiring maintenance. Complies with comfort and acoustic standards. Plug connected to diaphragm through bracket. Pressure set through PHILIPS screw. Its compact size allows interchangeability with most of the pressure reducing valves on the market. Brass DZR (corrocionresistant) body. Max. inlet pressure: 16 bar. Adjustable downstream pressure: 1,5 to 5,5 bar. Max. operating temp.: 80°C. Article number On request On request On request
M
N
Size 1/2" F 3/4" F 3/4" M
Unit 1 1 1
components for sanitary system
pressure reducing valve
Flanged pressure reducing valve DRVD16
159
Flanged pressure reducing valve with single spring-compensated seat, pressure gauge connections upstream and downstream 1/4" (DN 50 - 65) and 3/8" (DN 80 - 200). Cast iron body, cap and flanges with epoxy finish. Max. inlet pressure: 16 bar. Adjustable downstream pressures: standard version: 1.5 - 6 bar, special version: 2 - 8 bar / 4 - 12 bar. Can be used for water, air and neutral gases up to 80°C. Flanged connections UNI 2223. Article number 0504053 0504068 0504083 0504103 0504128 0504153 0504203 0504054 0504069 0504084 0504104 0504129 0504154 0504204 0504055 0504070 0504085 0504105 0504130 0504155 0504205
Size 50 65 80 100 125 150 200 50 65 80 100 125 150 200 50 65 80 100 125 150 200
Bar 1.5 - 6 1.5 - 6 1.5 - 6 1.5 - 6 1.5 - 6 1.5 - 6 1.5 - 6 2-8 2-8 2-8 2-8 2-8 2-8 2-8 4 - 12 4 - 12 4 - 12 4 - 12 4 - 12 4 - 12 4 - 12
Unit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Flanged pressure reducing valve DRVD25 Flanged pressure reducing valve with single spring-compensated seat, pressure gauge connections upstream and downstream 1/4" (DN 50 - 65) and 3/8" (DN 80 - 200). Cast iron body, cap and flanges with epoxy finish. Max. inlet pressure: 25 bar. Adjustable downstream pressures: standard version: 1.5 - 6 bar, special version: 2 - 8 bar / 4 - 12 bar. Can be used for water, air and neutral gases up to 80°C. Flanged connections UNI 2223. Article number 0504050 0504065 0504080 0504100 0504125 0504150 0504200 0504051 0504066 0504081 0504101 0504126 0504151 0504201 0504052 0504067 0504082 0504102 0504127 0504152 0504202
Size 50 65 80 100 125 150 200 50 65 80 100 125 150 200 50 65 80 100 125 150 200
Bar 1.5 - 6 1.5 - 6 1.5 - 6 1.5 - 6 1.5 - 6 1.5 - 6 1.5 - 6 2-8 2-8 2-8 2-8 2-8 2-8 2-8 4 - 12 4 - 12 4 - 12 4 - 12 4 - 12 4 - 12 4 - 12
Unit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
M
N O
components for sanitary system
pressure reducing valve
Flanged pressure reducing valve DRVD40
160
Flanged pressure reducing valve with single spring-compensated seat, pressure gauge connections upstream and downstream 1/4" (DN 50 - 65) and 3/8" (DN 80 - 200). Cast iron body, cap and flanges with epoxy finish. Max. inlet pressure: 40 bar. Adjustable downstream pressures: standard version: 1.5 - 6 bar, special version: 2 - 8 bar / 4 - 12 bar. Can be used for water, air and neutral gases up to 80°C. Flanged connections UNI 2223.
A
Article number 0504056 0504071 0504086 0504106 0504131 0504156 0504057 0504072 0504087 0504107 0504132 0504157 0504058 0504073 0504088 0504108 0504133 0504158
Size 50 65 80 100 125 150 50 65 80 100 125 150 50 65 80 100 125 150
Pressure reducing valves series
Bar 1.5 - 6 1.5 - 6 1.5 - 6 1.5 - 6 1.5 - 6 1.5 - 6 2-8 2-8 2-8 2-8 2-8 2-8 4 - 12 4 - 12 4 - 12 4 - 12 4 - 12 4 - 12
Unit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
drvd 9
Flow rate chart - Pressure drop
2 [ bar]
5
0,1
7
10
Pressure Drop
0,2
M
0,3 0,4 0,6
8
ND 20 ND 0 15 ND 0 1 ND 25 1 ND 00 80
4
ND 6 ND 5 50
1
0,8
Legend :
1 1,5 50 60
80 100
200
300 400
600 800 1000
Flow rate
N
3
6
2000
3000
5000
[l/min]
1 2 3 4 5 6 7 8 9 10
Body Cap Plug Packing Spring Seal ring Guide bushings Lip seal Setting screw Cap mounting screws
components for sanitary system
automatic control valve
Automatic self-acting control valve SERIES EU100
161
Automatic self-acting control valve designed for regulating water flow in water pipelines, such as: waterworks, irrigation, fire-fighting, process plants, etc. The main functions performed by the valve (also valve combinations) are as follows: - shut-off-check-reduction, stabilization of the pressure-relief, overpressure-pressure support-level control-flow control. The more advanced models are equipped with a central control unit (EU900), of AISI 303 stainless steel construction, which allows the regulating action to be performed as required by setting the flow opening and closing speeds as well as the response gradient to the deviations. The pilot devices serve for determining the type of function and the set-point of the parameter under control. All valves are provided with visual indication of the valve plug stem position.
Technical characteristics common to all models
Valve body and cover
Malleable cast iron GGG40 with full epoxy lining 150 µ
Stem guide in the cover
Self-lubricating bronze
Inner valve parts
Steel AISI (316, 303, 302)
Piattelli membrana
Steel ASTM AA 36 (DN 50-150) or cast iron GGG25 (DN 200-600) with full epoxy lining
Plug seal and diaphragm Body and cover, pilot device Piping and fittings, pilot circuit Minimum operating differential pressure Max. operating temperature
1
Closing speed
CS
Nitrile rubber BUNA N 70 Sh Nickel-plated bronze
2
Opening speed
6 5 4 3 2 1 0
0 1 2 3 4 5 6
OS
3 4
Reaction speed
Nickel-plated brass 0.25 bar (standard spring) 0.50 bar (reinforced spring) 70 °C
0 1 2 3 4 5 6
RS
5
FUNCTIONS The self-acting valves of Series EU100 consist of a main two-way body of globe type Fig 1, whose flow section is controlled by a shaped plug actuated by the energy supplied by the flow under control through a diaphragm inserted between the body and cover to form the operating chamber. When a small quantity of the fluid flows through the water control circuit, this circuit places the following ports in communication with each other : - upstream port with pressure generally higher - downstream port with pressure generally lower - port of the operating chamber with regulated intermediate pressure.
7 EU900 1 2 3 4 5 6 7
Outlet connection towards the control chamber Setting of closing speed 6 Setting of opening speed Outlet connection towards the pilot Calibration of the gradient of response to deviations Inlet connection of the upstream port Positioning of plate padlock
An adjustable throttle is installed at the outlet of the upstream port, and before communication with the operating chamber. The pilot device is installed at the inlet of the downstream port. When the pilot device is fully open Fig 2 it allows direct discharge of the operating fluid coming from the upstream port; this causes a drop in pressure due to the throttling and determines a low level of pressure in the operating chamber and discharge of the latter. The valve plug is raised to full opening position, thrust by the fluid under control. The fully closed pilot device Fig 3 causes the same high pressure present on upstream side to be present in the operating chamber (throttling with zero flow does not cause drops) and determines the fluid under control to be shut-off. When the pilot device is in intermediate position Fig 4 it allows partial discharge of the operating fluid coming from the upstream port; this produces a proportional drop in pressure due to the throttling and determines, in the operating chamber, an intermediate level of pressure and volu me. Hence the valve plug modulates the lifting of the valve plug (in opening or in closing) thus ensuring that the required levels of flow or pressure are reached.
Fig. 1
flow
Fig. 2
M
N flow
Fig. 3
flow
Fig. 4
O
components for sanitary system
automatic control valve
162
A
Self-acting diphragm valve EU115 Self-acting diapraghm valve serving to reduce and stabilize the downstream pressure. The higher, upstream pressure is adjusted, on downstream side, to a lower and constant level even in the presence of upstream overpressure and / or variations in flow rate. Version with needle valves. Adjustment range of pilot device: Standard: 1,4 - 12,0 bar. On request: 0,1 - 2,0 bar, 7,0 - 21,0 bar (stainless steel version). The additional non-return function is available on request (EU115-3). Article number On request On request On request On request On request On request On request On request On request On request On request On request On request
Size 50 65 80 100 125 150 200 250 300 350 400 500 600
PN 10/16 10/16 10/16 10/16 10/16 10/16 16 16 16 16 16 16 16
Kvs 47 52 58 120 215 228 456 847 1370 1450 1767 2480 3205
Unit 1 1 1 1 1 1 1 1 1 1 1 1 1
Self-acting diphragm valve EU115-UR Self-acting diapraghm valve serving to reduce and stabilize the downstream pressure. With regulator unit EU900. The higher, upstream pressure is adjusted, on downstream side, to a lower and constant level even in the presence of upstream overpressure and / or variations in flow rate. Version with needle valves. Adjustment range of pilot device: Standard: 1,4 - 12,0 bar. On request: 0,1 - 2,0 bar, 7,0 - 21,0 bar (stainless steel version). The additional non-return function is available On request (EU115-3).
M
Article number On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request
N flow
Size 50 65 80 100 125 150 200 200 250 250 300 300 350 350 400 400 500 500 600 600
PN 10/16 10/16 10/16 10/16 10/16 10/16 10 16 10 16 10 16 10 16 10 16 10 16 10 16
Kvs 47 52 58 120 215 228 456 456 847 847 1370 1370 1450 1450 1767 1767 2480 2480 3205 3205
Unit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
components for sanitary system
automatic control valve
Self-acting diphragm valve EU116
163
Self-acting diapraghm valve serving to hold the downstream pressure at a constant and adjustable level. When the level of upstream pressure tends to decrease, it is held by gradually reducing the flow rate; instead when the downstream pressure level tends to increase, it is held by gradually increasing the flow rate at the outlet (relief or overpressure function). Version with needle valves. Adjustment range of pilot device: standard: 1,4 - 12,0 bar. On request: 0,1 - 2,0 bar, 7,0 - 21,0 bar (stainless steel version). The additional non-return function is available on request (EU116-3). Article number On request On request On request On request On request On request On request On request On request On request On request On request On request
Size 50 65 80 100 125 150 200 250 300 350 400 500 600
PN 10/16 10/16 10/16 10/16 10/16 10/16 16 16 16 16 16 16 16
Kvs 47 52 58 120 215 228 456 847 1370 1450 1767 2480 3205
Unit 1 1 1 1 1 1 1 1 1 1 1 1 1
Self-acting diphragm valve EU116-UR Self-acting diapraghm valve serving to hold the downstream pressure at a constant and adjustable level. With regulator unit EU900. When the level of upstream pressure tends to decrease, it is held by gradually reducing the flow rate; instead when the downstream pressure level tends to increase, it is held by gradually increasing the flow rate at the outlet (relief or overpressure function). Version with needle valves. Adjustment range of pilot device: standard: 1,4 - 12,0 bar. On request: 0,1 - 2,0 bar, 7,0 - 21,0 bar (stainless steel version). The additional non-return function is available on request (EU116-3). Article number On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request
Size 50 65 80 100 125 150 200 200 250 250 300 300 350 350 400 400 500 500 600 600
PN 10/16 10/16 10/16 10/16 10/16 10/16 10 16 10 16 10 16 10 16 10 16 10 16 10 16
Kvs 47 52 58 120 215 228 456 456 847 847 1370 1370 1450 1450 1767 1767 2480 2480 3205 3205
Unit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
M
N flow
O
components for sanitary system
automatic control valve
164
A
Self-acting diphragm valve EU114 Self-acting diapraghm valve serving to control the flow rate passing the valve at a constant and settable value: normally the maximum acceptable drawing off value is held. The flow rate is monitored continuously through a calibrated flange located upstream of the valve, whose piezometric sockets are connected to the special pilot device which also allows setting with a differential pressure gauge. Version with needle valves. Obviously the available flow rate range (see table below) depends on the DN and calibrated flange; therefore it should be stated when ordering. Range of differential pressure adjustment with standard pilot device: 0,2 - 1 bar. Article number On request On request On request On request On request On request On request On request On request On request On request On request On request
Size 50 65 80 100 125 150 200 250 300 350 400 500 600
PN 10/16 10/16 10/16 10/16 10/16 10/16 16 16 16 16 16 16 16
Kvs 47 52 58 120 215 228 456 847 1370 1450 1767 2480 3205
Unit 1 1 1 1 1 1 1 1 1 1 1 1 1
Self-acting diphragm valve EU114-UR Self-acting diapraghm valve serving to control the flow rate passing the valve at a constant and settable value: normally the maximum acceptable drawing off value is held. With regulator unit EU900.The flow rate is monitored continuously through a calibrated flange located upstream of the valve, whose piezometric sockets are connected to the special pilot device which also allows setting with a differential pressure gauge. Version with needle valves. Obviously the available flow rate range (see table below) depends on the DN and calibrated flange. Range of differential pressure adjustment with standard pilot device: 0,2 - 1 bar.
M
Article number On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request
N flow
Size 50 65 80 100 125 150 200 200 250 250 300 300 350 350 400 400 500 500 600 600
PN 10/16 10/16 10/16 10/16 10/16 10/16 10 16 10 16 10 16 10 16 10 16 10 16 10 16
Kvs 47 52 58 120 215 228 456 456 847 847 1370 1370 1450 1450 1767 1767 2480 2480 3205 3205
Unit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
components for sanitary system
automatic control valve
Self-acting diphragm valve EU127
165
Self-acting diapraghm valve with function of piezometric level control for the tank (piezometric tower). The valve closes the flow when max. level is reached, then it is reopened proportionally with a variable proportional band from 0,3 to 1,0 m w.g. depending on the adjustment range chosen. The piezometric pilot device is fastened to the main valve located at the bottom of the tank and is connected to the latter with piezometric tubes (not included in the supply). Version with needle valves. Adjustment range of pilot device: standard: 3 - 20 m w.g. On request: 1 - 6 m w.g. or 16 - 65 m w.g. Article number On request On request On request On request On request On request On request On request On request On request On request On request On request
Size 50 65 80 100 125 150 200 250 300 350 400 500 600
PN 10/16 10/16 10/16 10/16 10/16 10/16 16 16 16 16 16 16 16
Kvs 47 52 58 120 215 228 456 847 1370 1450 1767 2480 3205
Unit 1 1 1 1 1 1 1 1 1 1 1 1 1
Self-acting diphragm valve EU127-UR Self-acting diapraghm valve with function of piezometric level control for the tank (piezometric tower). With regulator unit EU900. The valve closes the flow when max. level is reached, then it is reopened proportionally with a variable proportional band from 0,3 to 1,0 m w.g. depending on the adjustment range chosen. The piezometric pilot device is fastened to the main valve located at the bottom of the tank and is connected to the latter with piezometric tubes (not included in the supply). Version with needle valves. Adjustment range of pilot device: standard: 3 - 20 m w.g. On request: 1 - 6 m w.g. or 16 - 65 m w.g. Article number On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request
Size 50 65 80 100 125 150 200 200 250 250 300 300 350 350 400 400 500 500 600 600
PN 10/16 10/16 10/16 10/16 10/16 10/16 10 16 10 16 10 16 10 16 10 16 10 16 10 16
Kvs 47 52 58 120 215 228 456 456 847 847 1370 1370 1450 1450 1767 1767 2480 2480 3205 3205
Unit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
M
N flow
O
components for sanitary system
automatic control valve
166
A
Self-acting diphragm valve EU110-14 Self-acting diapraghm valve with function of float type level control for storage tanks in general. The valve closes the flow when max. level is reached, then reopens it at minimum level. Version with needle valves. The float pilot device is normally placed inside the tank while the main valve is at the bottom of the tank. The float operating rod allows setting the differential between max. and min. levels between 0,5 and 2,0 metres. Standard rod length 2 metres. Article number On request On request On request On request On request On request On request On request On request On request On request On request On request
Size 50 65 80 100 125 150 200 250 300 350 400 500 600
PN 10/16 10/16 10/16 10/16 10/16 10/16 16 16 16 16 16 16 16
Kvs 47 52 58 120 215 228 456 847 1370 1450 1767 2480 3205
Unit 1 1 1 1 1 1 1 1 1 1 1 1 1
Self-acting diphragm valve EU110-14-UR Self-acting diapraghm valve with function of float type level control for storage tanks in general. With regulator unit EU900. The valve closes the flow when max. level is reached, then reopens it at minimum level. Version with needle valves. The float pilot device is normally placed inside the tank while the main valve is at the bottom of the tank. The float operating rod allows setting the differential between max. and min. levels between 0,5 and 2,0 metres. Standard rod length 2 metres. Article number On request On request On request On request On request On request On request On request On request On request On request On request On request
Size 50 65 80 100 125 150 200 250 300 350 400 500 600
M
N
flow
PN 10/16 10/16 10/16 10/16 10/16 10/16 16 16 16 16 16 16 16
Kvs 47 52 58 120 215 228 456 847 1370 1450 1767 2480 3205
Unit 1 1 1 1 1 1 1 1 1 1 1 1 1
components for sanitary system
automatic control valve
Self-acting diphragm valve EU110-10
167
Self-acting diapraghm valve with function of float type level control for storage tanks in general. The valve opens the flow when max. level is reached, then closes it at minimum level (overflow version). Version with needle valves. The float pilot device is normally placed inside the tank while the main valve is at the bottom of the tank. The float operating rod allows setting the differential between max. and min. levels between 0,5 and 2,0 metres. Standard rod length 2 metres. Article number On request On request On request On request On request On request On request On request On request On request On request On request On request
Size 50 65 80 100 125 150 200 250 300 350 400 500 600
PN 10/16 10/16 10/16 10/16 10/16 10/16 16 16 16 16 16 16 16
Kvs 47 52 58 120 215 228 456 847 1370 1450 1767 2480 3205
Unit 1 1 1 1 1 1 1 1 1 1 1 1 1
Self-acting diphragm valve EU110-10-UR Self-acting diapraghm valve with function of float type level control for storage tanks in general. With regulator unit EU900. The valve opens the flow when max. level is reached, then closes it at minimum level (overflow version). Version with needle valves. The float pilot device is normally placed inside the tank while the main valve is at the bottom of the tank. The float operating rod allows setting the differential between max. and min. levels between 0,5 and 2,0 metres. Standard rod length 2 metres. Article number On request On request On request On request On request On request On request On request On request On request On request On request On request
Size 50 65 80 100 125 150 200 250 300 350 400 500 600
PN 10/16 10/16 10/16 10/16 10/16 10/16 16 16 16 16 16 16 16
Kvs 47 52 58 120 215 228 456 847 1370 1450 1767 2480 3205
Unit 1 1 1 1 1 1 1 1 1 1 1 1 1
M
N flow
O
components for sanitary system
automatic control valve
168
A
Self-acting diphragm valve EU113 Self-acting diapraghm valve serving to shut off the flow rate through the valve via a remote electrical control. The pilot circuit is provided with a solenoid valve, whose function must be stated whether as normally open (NO) or normally closed (NC). Version with needle valves. The additional non-return function is available on request. Article number On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request
Size 50 65 80 100 125 150 200 200 250 250 300 300 350 350 400 400 500 500 600 600
PN 10/16 10/16 10/16 10/16 10/16 10/16 10 16 10 16 10 16 10 16 10 16 10 16 10 16
Kvs 47 52 58 120 215 228 456 456 847 847 1370 1370 1450 1450 1767 1767 2480 2480 3205 3205
Unit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Self-acting diphragm valve EU113-UR Self-acting diapraghm valve serving to shut off the flow rate through the valve via a remote electrical control. With regulator unit EU900. The pilot circuit is provided with a solenoid valve, whose function must be stated whether as normally open (NO) or normally closed (NC). Version with needle valves. The additional non-return function is available on request.
M
Article number On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request
N flow
Size 50 65 80 100 125 150 200 200 250 250 300 300 350 350 400 400 500 500 600 600
PN 10/16 10/16 10/16 10/16 10/16 10/16 10 16 10 16 10 16 10 16 10 16 10 16 10 16
Kvs 47 52 58 120 215 228 456 456 847 847 1370 1370 1450 1450 1767 1767 2480 2480 3205 3205
Unit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
components for sanitary system
check valve
Cast iron check valve FC
169
Spheroidal cast iron check valve with flanged connections. Check function controllable according to EN 13959. Field of application: - as anti-pollution device in drinking water supply with EA protection according to EN1717. - as non return (check) valve in all hot and cold domestic water supply circuits, in distribution networks of fluid operating in the systems, in pumping stations, etc. Operating pressure: 16 bar. Max. operating temperature: 70°C. Min. temperature: 4°C. Spheroidal cast iron body. Pull-out polymeric functional device (check). Elastomeric parts: NBR. Other components: stainless steel. Approvals: Belgaqua. Article number 308065361 308080361 308100361 308125361 308150361 308200361 308250361
DN 65 80 100 125 150 200 250
Size Flanged Flanged Flanged Flanged Flanged Flanged Flanged
Press PN16 PN16 PN16 PN16 PN16 PN16 PN16
Unit 1 1 1 1 1 1 1
FC idraulic caracteristic
M
N O
components for sanitary system
butterfly and shut-off valve
170
Bronze gate valve 240 Bronze gate valve with sleeve. Max. pressure: 16 bar. Operating temperature: -15 to 80°C.
A
Article number 24012 24034 2401 240114 240112 2402 240212 2403 2404
Size 1/2" F 3/4" F 1" F 1.1/4" F 1.1/2" F 2" F 2.1/2" F 3" F 4" F
Unit 6 6 10 10 5 5 1 1 1
Solenoid valve for water 850T Solenoid valve for water. Operating temperature: -10°C / +90°C. Max. pressure: 25 bar. Normally closed (NC). Normally open (NO). Article number 850T38W220 850T38W24 850T12W220 850T12W24 850T34W220 850T34W24 850T1W220 850T1W24 850T35W220NA 850T38W24NA 850T12W220NA 850T12W24NA 850T34W220NA 850T34W24NA 850T1W220NA 850T1W24NA
M
N
Size 3/8" 3/8" 1/2" 1/2" 3/4" 3/4" 1" 1" 3/8" 3/8" 1/2" 1/2" 3/4" 3/4" 1" 1"
Kvs 230 VAC 24 VAC 230 VAC 24 VAC 230 VAC 24 VAC 230 VAC 24 VAC 220 V 24 VAC 220 V 24 VAC 220 V 24 VAC 220 V 24 VAC
Unit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
components for sanitary system
water hammer arrestor
Mini water hammer arrestor serie 05 (APW)
171
Mini sliding piston water hammer arrestor in sealed copper tube. Can be installed in any position. Does not require maintenance. Suitable for washing machines, dish washers, sinks, sanitary systems, etc. Nickel-plated copper body. Acetal resin piston. Precharging pressure: 4 bar. Operating pressure: 10 bar. Peak pressure: 16 bar. Max. temperature: 85°C.
Article number 473015005
DN 15
Size 1/2" M
Unit 1
Water hammer arrestor serie 15 (CAW) Water hammer arrestor like APW but with double sealed brass piston (O-ring and EPDM). Peak pressure: 20 bar. Max. temperature: 110°C. According to ASSE, ANSI, PDI.
Article number 472015100
DN 15
Size 1/2" M
Unit 1
Water hammer arrestor serie 150A (WAM) Water hammer arrestor designed for washing machines, dish washers, sinks, sanitary systems, etc. Can be installed in any position. Painted stainless steel body. Elastomeric diaphragm. Max. temperature: 90°C. Precharging pressure: 3 bar. Peak pressure: 13 bar. Capacity: 0,16 litres.
Article number 472015100
DN 15
Selection of water hammer arrestors series
Size 1/2" M
Unit 1
caw
UNI 9182 standard cites: "All hot and cold water distribution systems must be provided with water hammer arrestors of hydropneumatic type (with permanent or resettable air cushions)." Each model of the CAW series is able to offer a certain cushioning action (table 1); hence for facilitating the choice we have given a table (table 2) with the unit load values assigned to each shut-off component (or units) normally installed in plumbing and hot water systems. N.B. Install the water hammer arrestor as close as possible to the shut-off component causing the water hammer. Table 1 SELECTION OF WATER HAMMER ARRESTOR ACCORDING TO THE UNIT LOAD NUMBER MODEL Nd Protection Unit load APW -CAW -WAM 1/2" M A 1 - 11 CAW 3/4" M B 12 - 32 CAW 1" M C 33 - 60 CAW 1.1/4" M D 61 - 113 CAW 1.1/2" M E 114 - 154 CAW 2" M F 155 - 330
BATH SUITE complete with quick flushing = 8 load units - 1 CAW or WAM 1/2"
M
Table 2 APPLIANCE Quick flushing WC Float WC Wash basins Bath-tub Bidet Shower Washing machine/dish washer Sink Bath suite complete with quick flushing WC Bath suite complete with float WC
UNIT LOAD 6 3 1 2 1 1 2 2 8 6
N O
components for sanitary system
thermostatic mixing valve
172
A
Thermostatic mixing valve MINIMIX Thermostatic mixing valve. Designed to supply sinks, hand wash-basins or electronic faucets. Provides high security level against scalding and Legionella bacteria. Ideal for multi-facility applications: hospitals, nursing homes, hotels, schools, restaurants, laboratories. Body: DZR brass CW602N chrome polished. Cap: ABS. Max. working pressure: 10 bar. Factory set temperature: 38°C. Minimum flow rate: 5 l/min. Under 1 bar: 14,9 l/min, 2 bar: 22 l/min, 3 bar: 25 l/min. Temperature setting range: 30°C to 70°C. Max. inlet hot water: 85°C. * = 3/8” (12x17) flat sealing. ** = 1/2” (15x21) flat sealing. Cartridge replace: TCP6. Compliance with EN1111. Article number 0559510
Size 3/8” F
Unit 1
Compact thermostatic mixing valve MMV-C Compact thermostatic mixing valve designed to supply general purpose applications with tempered water not exceeding a set temperature. Ideal for multi-facility applications: domestic homes, schools, restaurants, laboratories, motorway services, commercial buildings... anywhere needing a supply of water at a temperature pre-set on site. Rapid fail safe if cold water supply is interrupted (comply with EN1111 and with BS1415 Pt 2 - TMV2). 1/2” or 3/4” Male/Male union threaded on inlets and outlets or compression fitting 15 or 22 mm. Pressure at the valve inlets must be within the 5:1 ratio under flow conditions. The size and layout of pipework and in-line fittings must take this into consideration. Optimum performance achieved with equal pressure. Temperature: accurate to within 1,5°C of chosen temperature (with balanced dynamic pressure). Head loss under dynamic presure at the mixer inlets is shown by the curve. Maximum static pressure: 10 bar. Operating pressure: 0,2 to 5 bar. Hot temperature supply: 52* - 85°C, *differential minimum hot/mix temperature must be 10°C. Cold temperature supply: 5 - 20°C. Temperature setting range: 30 to 65°C. Factory temperature setting: 36°C. Flow rate at 3 bar: 57 l/min. Flow mini: 5 l/min. Body strenght: 25 bar. * Cap = Graduated scale - ** Cap = Click cover cap Article number On request* On request* On request* On request*
M
On On On On On
request* request** request** request** request**
On On On On On
request** request* request* request* request*
On On On On On
request* request** request** request** request**
On request**
N
Type 1” with G 1/2” male union threaded 1” with G 3/4” male union threaded 1” with compression fitting 22 mm 1” with compression fitting 22 mm and 15 mm adapter 1” DN 25 male threaded 1” with G 1/2” male union threaded 1” with G 3/4” male union threaded 1” with compression fitting 22 mm 1” with compression fitting 22 mm and 15 mm adapter 1” DN 25 male threaded 1” with G 1/2” male union threaded 1” with G 3/4” male union threaded 1” with compression fitting 22 mm 1” with compression fitting 22 mm and 15 mm adapter 1” DN 25 male threaded 1” with G 1/2” male union threaded 1” with G 3/4” male union threaded 1” with compression fitting 22 mm 1” with compression fitting 22 mm and 15 mm adapter 1” DN 25 male threaded
Finish Nickel-plated Nickel-plated Nickel-plated Nickel-plated
Unit 1 1 1 1
Nickel-plated Nickel-plated Nickel-plated Nickel-plated Nickel-plated
1 1 1 1 1
Nickel-plated Self colour brass Self colour brass Self colour brass Self colour brass
1 1 1 1 1
Self Self Self Self Self
brass brass brass brass brass
1 1 1 1 1
Self colour brass
1
colour colour colour colour colour
components for sanitary system
thermostatic mixing valve
Thermostatic mixing valve TL
173
Thermostatic mixer for widely differing applications such domestic applications, in schools, restaurants, etc. Wall-mounted fixture, not graduated, to be set during installation phase. Brass body, white polypropylene. Protection knob fastened by socket head screw. Hot/cold water inlet 1/2” F. Two mixed water outlets (at bottom or top) 1/2” F. Anti-scald protection: water shut off in less than 2 seconds in the event of cold water missing. Max. pressure: 10 bar. Setting range: 5 ÷ 80°C. Max. hot water temperature: 85°C. Mixer warranted for 2 years. Article number 0559615
Size 1/2” F
N° of users 3-4
Flow rate l/min 42 (at 3 bar)
Unit 1
Thermostatic mixing valve T9B/C Thermostatic mixer for the community, suitable for all sanitary appliances (showers, wash basins). It allows controlling and holding the temperature of the mixed water to a constant value also in the presence of variations in pressure (max. 1,5 bar). Hot water inlet provided on the left, mixed water outlet at the top. Brass body. Graduated knob, either white ABS or chromeplated. Anti-scald protection: water shut off in less than 2 seconds in the event of cold water missing. Operating pressure: 10 bar. Setting range: 10°C ÷ 50°C. Max. hot water temperature: 85°C. * as a guide consider the simultaneity coefficient. Article number T9715B T9715C T9107B T9107C
Size 1/2” M 1/2” M 3/4” M 3/4” M
N° of users 1-5 1-5 1-5 1-5
Flow rate l/min 3 - 42* 3 - 42* 3 - 42* 3 - 42*
Unit 1 1 1 1
Thermostatic mixing valve ULTRAMIX TX90 Visible thermostatic mixers for community installations such as swimming pools, sports centres, schools, factories, camping sites, hospitals, spas, etc. which allow controlling and holding of the mixed water temperature at a constant level also on the presence of variations in pressure (max. 1,5 bar). Brass body. Cover with grey epoxy finish and blue graduated knob. Chrome-plated cover with white graduated knob. Anti-seize mechanism with filters and check valves. Bimetal steel strip coated with rilsan to protect against scale formation. Temperature setting range: 10°C ÷ 50°C (on request 30 to 70°C and 50 and 90°C) with provision or locking. Anti-scald protection: water shut off in less than 2 seconds in the event of cold water missing. Max. operating pressure: 10 bar. Max. hot water temperature: 85°C. Flow rates guaranteed with upstream dynamic pressure: 3 bar. Hot water inlet provided on the left, mixed water outlet at the top. Min. difference in inlet/outlet temperature: 5°C. * as a guide consider the simultaneity coefficient. Article number TX91E TX91C TX92E TX92C TX93E TX93C TX94E TX94C TX95E TX95C TX96E TX96C
Size 3/4” M 3/4” M 3/4” M 3/4” M 1” M 1” M 1.1/4” M 1.1/4” M 1.1/2” M 1.1/2” M 2” M 2” M
N° of users 1-7 1-7 1 - 10 1 - 10 1 - 15 1 - 15 1 - 21 1 - 21 1 - 32 1 - 32 1 - 50 1 - 50
Flow rate l/min 3 - 56* 3 - 56* 3 - 80* 3 - 80* 3 - 120* 3 - 120* 5 - 175* 5 - 175* 5 - 260* 5 - 260* 6 - 400* 6 - 400*
Unit 1 1 1 1 1 1 1 1 1 1 1 1
M
N O
components for sanitary system
thermostatic mixing valve
174
A
Thermostatic mixing valve ULTRAMIX TX90FIX Visible thermostatic mixers for community installations such as swimming pools, sports centres, schools, factories, camping sites, hospitals, spas, etc. which allow controlling and holding of the mixed water temperature at a constant level also on the presence of variations in pressure (max. 1,5 bar). Brass body. Cover with grey epoxy finish and blue graduated knob. Chrome-plated cover with white graduated knob. Anti-seize mechanism with filters and check valves. Bimetal steel strip coated with rilsan to protect against scale formation. Temperature setting range: 10°C ÷ 50°C (on request 30 to 70°C and 50 and 90°C) with provision or locking. Anti-scald protection: water shut off in less than 2 seconds in the event of cold water missing. Max. operating pressure: 10 bar. Max. hot water temperature: 85°C. Flow rates guaranteed with upstream dynamic pressure: 3 bar. Hot water inlet provided on the left, mixed water outlet at the top. Min. difference in inlet/outlet temperature: 5°C. Article number On request On request On request On request
Size 1/2” F 3/4” F 3/4” F 1” F
N° of users 1-5 1-7 1 - 10 1 - 15
Flow rate l/min 3 - 42 3 - 56 3 - 80 3 - 120
Unit 1 1 1 1
Thermostatic mixing valve ULTRAMIX TX90CHP Visible thermostatic mixers for community installations such as swimming pools, sports centres, schools, factories, camping sites, hospitals, spas, etc. which allow controlling and holding of the mixed water temperature at a constant level also on the presence of variations in pressure (max. 1,5 bar). Brass body. Cover with grey epoxy finish and blue graduated knob. Chrome-plated cover with white graduated knob. Anti-seize mechanism with filters and check valves. Bimetal steel strip coated with rilsan to protect against scale formation. Temperature setting range: 10°C ÷ 50°C (on request 30 to 70°C and 50 and 90°C) with provision or locking. Anti-scald protection: water shut off in less than 2 seconds in the event of cold water missing. Max. operating pressure: 10 bar. Max. hot water temperature: 85°C. Flow rates guaranteed with upstream dynamic pressure: 3 bar. Hot water inlet provided on the left, mixed water outlet at the top. Min. difference in inlet/outlet temperature: 5°C. Article number On request On request On request On request On request On request
Size 3/4” M 3/4” M 1” M 1.1/4” M 1.1/2” M 2” M
N° of users 1-7 1 - 10 1 - 15 1 - 21 1 - 32 1 - 50
Flow rate l/min 3 - 56 3 - 80 3 - 120 5 - 175 5 - 260 6 - 400
Unit 1 1 1 1 1 1
Thermostatic mixing valve ULTRAMIX TX90OMDA
M
N
Visible thermostatic mixers for community installations such as swimming pools, sports centres, schools, factories, camping sites, hospitals, spas, etc. which allow controlling and holding of the mixed water temperature at a constant level also on the presence of variations in pressure (max. 1,5 bar). Brass body. Cover with grey epoxy finish and blue graduated knob. Chrome-plated cover with white graduated knob. Anti-seize mechanism with filters and check valves. Bimetal steel strip coated with rilsan to protect against scale formation. Temperature setting range: 10°C ÷ 50°C (on request 30 to 70°C and 50 and 90°C) with provision or locking. Anti-scald protection: water shut off in less than 2 seconds in the event of cold water missing. Max. operating pressure: 10 bar. Max. hot water temperature: 85°C. Flow rates guaranteed with upstream dynamic pressure: 3 bar. Hot water inlet provided on the left, mixed water outlet at the top. Min. difference in inlet/outlet temperature: 5°C. Article number On request On request On request
Size 3/4” M 3/4” M 1” M
N° of users 1-7 1 - 10 1 - 15
Flow rate l/min 3 - 56 3 - 80 3 - 120
Unit 1 1 1
components for sanitary system
thermostatic mixing valve
Precision thermometer T109
175
High precision thermometer with rapid response: 4°C / second. To be installed directly at the mixed water outlet. Article number On request On request On request On request On request
Size 3/4” MF 1” MF 1.1/4” MF 1.1/2” MF 2” MF
Unit 1 1 1 1 1
Thermostatic mixing valve serie 170 Thermostatic mixer for central systems. Bronze body. Max. pressure: 10 bar. Max. temperature: 95°C. Min. flow rate (for all diameters): 34 l/min. Model 2” DN with cold water inlet size 1.1/2”. Article number 441020000 441025000 441032000 441040000 441050000 442020000 442025000 442032000 442040000 442050000
Size 3/4” F 1” F 1.1/4” F 1.1/2” F 2” F 3/4” F 1” F 1.1/4” F 1.1/2” F 2” F
Setting range 55 - 80°C 55 - 80°C 55 - 80°C 55 - 80°C 55 - 80°C 38 - 55°C 38 - 55°C 38 - 55°C 38 - 55°C 38 - 55°C
Unit 1 1 1 1 1 1 1 1 1 1
M
N O