Preview only show first 10 pages with watermark. For full document please download

Configure Your Fuzzyscan

   EMBED


Share

Transcript

Configure Your FuzzyScan Configure Your FuzzyScan Before you trying to configure the FuzzyScan, you must refer to the Quick Installation chapter of reading devices or other equipment to settle the installation. Otherwise, unexpected conditions may occur while setting the FuzzyScan. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding There are two ways to configure your FuzzyScan, depending on the model you brought from your vendors. Via FuzzyScan PowerTool PowerTool is a unique software utility designed for FuzzyScan Gold/Jade/Diamond series scanners only. It has been designed to operate under Microsoft Windows 95, 98, NT or above. To use the PowerTool, you will enjoy the convenience on your fingertip. Via Bar Code Programming Menu The bar code programming menu is designed for field programming convenience. All FuzzyScan family scanners can take this way to make detailed configurations. Before you using the bar code programming menu, please understand the command structure and various programming procedures in advance. 3-1 Configure Your FuzzyScan then perform your desired action. FuzzyScan PowerTool PowerTool is the only Microsoft Windows 95/98/NT based software utility available in the Auto ID industry. This software utility has totally changed the way to manage the intelligent bar code reading device, and has redefined the terminology of user-friendly in this industry. These extra benefits brought to you are done via outstanding software designs and on-board hardware breakthrough with the most advanced Flash Memory ASIC. If you are the user of FuzzyScan Gold/Jade/Diamond series scanners, you can obtain the PowerTool Kit in lowest cost as bonus. With innovative design, PowerTool can provide you the convenience of: ƒ User Friendly On-screen Configuration ƒ Configuration Download and Upload ƒ Program (Firmware) Field Upgrade ƒ Simple On-site Diagnostic ƒ Full-feature Data Editor – DataWizard While you are asking PowerTool to do the “Download”, “Upload”, “Upgrade” and “Diagnostic” with FuzzyScan, PowerTool will ask you to use FuzzyScan to scan the “Host Link Command” for initial handshaking with PowerTool, 3-2 Configure Your FuzzyScan PowerTool at A Glance PowerTool Main Screen Host Interface Selection DataWizard Setting Bar Code Setting FuzzyScan PowerTool Host Link Command 3-3 Configure Your FuzzyScan Software Installation Especially, the hard copy of all parameters programmed can be obtained via the Convert feature. This feature will consolidate all programmable parameters for a certain application and print it out via your printer linked with the PC. This hard copy, then, can be filed for future reference or can be used in the field where no PC is available. PowerTool comes with the PowerTool Kit which includes the necessary cable sets, operation briefing and software delivered in CD ROM or floppy format. You will find the PowerTool has been delivered in a self-extracted file format. It includes all the necessary installation files to build a complete running program. When you put the self-extracted file into a pre-built subdirectory and execute this file, those installation files will be retrieved into this subdirectory immediately. Then you have to run the SETUP.EXE and follow the screen instruction to complete the installation of FuzzyScan PowerTool. Configuration Download and Upload The Download and Upload functions will let you see what the device is programmed for. Also you can retrieve (upload) the configurations from FuzzyScan or send (download) the configurations to FuzzyScan. Of course, to duplicate preset configurations will be easy as 1-2-3. After the installation procedure, a new FuzzyScan group folder will be added into the program menu, then you are ready to use the PowerTool. Program Field Upgrade Internal program (firmware) change or modification is only one step away via the Field Upgrade feature of the utility. This is what we called “ Investment Guaranty “ for all of the FuzzyScan universal models. On-screen Configuration Compared with the traditional configuration done via bar code menu readings, PowerTool will provide you a GUI interface to configure the FuzzyScan Universal Models easily. All configurations can be saved as a file format or convert to hard copy of print out for management convenience. On-Site Field Diagnostic You can perform Diagnostic to verify if the communication between your FuzzyScan and Host system is normal, and the buzzer and indicator light is working correctly. 3-4 Configure Your FuzzyScan “Transmission Time Control”. DataWizard DataWizard is an Artificial Intelligence based Expert System developed by the manufacturer to handle delicate data processing jobs before the scanned data been transmitted to the host system. The DataWizard Condensed Version has been embedded in all FuzzyScan family. You can get those desired functions via scanning bar code menu. The Full-Feature DataWizard is only available for FuzzyScan Gold/Jade/Diamond series (Universal Models), and must be configured through the PowerTool for advanced requirements. It will give you the freedom of modifying the scanned data anyway you like, and allow you to integrate the FuzzyScan Universal Models into any existing applications. Briefing The ultra powerful data editing functions provided by DataWizard are controlled by user definable Rule. Through independent rules, users can easily get following functionality: ƒ General Transmission Control The available parameters include “Preamble”, “Postamble”, “Suffix”, “Symbol ID and Data Length Transmission” and 3-5 Configure Your FuzzyScan ƒ Advanced Data Verification User can base on the desired Bar Code Symbologies to select “Valid ASCII Domain”, “Valid Data Length Domain” and “Matched Data Value” to establish any desired filtering algorithm. This feature is not only to provide on-scanner data filter without application software modification, but also can reduce the error reading rate and improve data capture reliability. ƒ Field Oriented Data Formatter The Field Oriented Data Formatter allows user to flexibly divide scanned data by “Delimiter” or “Length”. To use with “Added Field” and “Transmission Sequence Arrangement” features, user can implement “Insert”, “Delete”, “Replace”, “Re-organize” and other data editing capabilities beyond your imagination. If you can’t understand the actual operation of DataWizard, please consult your vendor or visit our web site for details. Then you will enjoy the wonderful tool on hand. http://www.htz.com.tw 3-6 Configure Your FuzzyScan Application Example Configuration Procedure If your bar code label is a 16-digit Code 39 which includes the information of 6-digit date code, 6-digit serial number and 4-digit unit price. You want the FuzzyScan to do the following for you without software modification: ƒ Select “Using 1 Rule”. ƒ Set “Applied Bar Code” to “Code 39”. ƒ Set “Valid ASCII Range” to “Numeric”. ƒ Select “Using Match 1”. ƒ Check bar code is Code 39 or not, then reject the invalid ƒ Set “Matched Data “ to “99”, and set “Start Position” to “1”. bar code input. ƒ Set “Original Field” to “Divide scanned data into 4 fields”. ƒ Check bar code content is numeric or not, then reject the Set “Field Divided By” of F1 to “Fixed Length” for “2”. invalid bar code input. Set “Field Divided By” of F2 to “Fixed Length” for “4”. ƒ Allow bar code output whose date code is leading with “99”. Set “Field Divided By” of F3 to “Fixed Length” for “6”. ƒ Three outputs with “TAB” suffix. Set “Field Divided By” of F4 to “Fixed Length” for “2” ƒ The date code output should skip “99” and replaced it with Then DataWizard will assign the rest 2 digits as “Last Field “AA”. (LF)” automatically. Please note that if the code 39 bar code ƒ The serial number output should be led with “S/N:”. label is printed with “Check Digit”, the last field will have 3 ƒ The first 2 digits of unit price output should be skipped. digits. ƒ Set ”Added Field” to “Insert 3 Added Fields”. ƒ The output sequence should be unit price, date code, and Set “AF1” (Added Field 1) to “AA”. serial number. Set “AF2” to “S/N:”. ƒ Test Bar Code : 9 9 1 0 2 5 1 2 3 4 5 6 9 8 7 6 Set “AF3” to “TAB (Hex 09)”. ƒ Actual Output : 76[TAB]AA1025[TAB]S/N:123456[TAB] ƒ Set “Transmission Sequence” to “LF”, “AF3”, “AF1”, “F2”, Please use FuzzyScan PowerTool to configure the full-feature “AF3”, “AF2”, “F3”, and “AF3”. DataWizard, and follow the procedures listed below. 3-7 Configure Your FuzzyScan Bar Code Programming Menu System Command The FuzzyScan bar code commands are specially designed Proprietary bar code labels which allow you to set the FuzzyScan internal programming parameters. There are System Command, Family Code and Option Code for programming purpose. The System Command is the highest level bar code command which directs FuzzyScan to perform immediate operations, such as entering programming mode (PROGRAM), exiting programming mode (EXIT), listing system information (SYSLIST), recovering to factory preset configurations (M_DEFAULT/G_DEFAULT), and so on. Please note that all system commands will take a few seconds to complete the operations. User must wait for the completion beeps before scanning another bar code. Each programmable family and bar code command label is listed on the same page with major system commands. The detailed explanations and special programming flowchart are printed on facing or following pages. You can read the explanation and set the FuzzyScan concurrently. Family Code A supplemental bar code command menu incorporates the bar code command labels of System Command and Option Code. As you set the FuzzyScan, open the bar code command menu to find the option code page. You may scan the desired family code and option code to set FuzzyScan. If you want to change the programming family for multiple settings, you need only turn over the programming page to find next desired programming family. The Family Code is scanned to select the user desired programming family. FuzzyScan has already provided more than one hundred programming families to meet any specific requirements. Option Code The Option Codes is a set of bar code commands represented by “0–9”, “A–F” and finishing selection (FIN). For most setting, you must select at least one option code following the family code selection to set the desired parameter for the selected programming family. 3-8 Configure Your FuzzyScan Programming Procedures If the programming family must take multiple scans selection, cycling scan selection, or dual level selection procedures, the family of the programming menu will be marked with the matched representing symbol of Programming Category (P.C.) in bold font listed in the following table. You can easily find the bold mark in the programming menu, and refer to their flowcharts for details. Before setting the FuzzyScan, please also refer to the “Beeping Indications” listed in Appendix to understand the details of programming beeping indications. It will be very helpful for you to know the existing status while you are programming the FuzzyScan. As you scan the bar code command to select the desired parameters, information about the final selected parameters represented by the bar code commands are stored in the FuzzyScan’s internal Flash Memory ASIC or non-volatile memory. If you turn off the unit, the Flash Memory ASIC or non-volatile memory retains all programming options. You need not re-program the FuzzyScan if you want to keep the existing configurations in the next power on. The programming procedures of FuzzyScan are designed as simple as possible for ease of setting. Most programming families take the Single Scan Selection programming procedure. But several programming families have more complex and flexible programmable options, and you must take Multiple Scans Selection, Cycling Scan Selection or Dual Level Selection to complete their programming procedures. Each kind of programming procedure is listed in the following pages for your reference. Please give careful attention to become familiar with each programming procedure. However, if you are the user of FuzzyScan Gold/Jade/Diamond series scanners, you are encouraged to use the PowerTool for convenience. Conventions of Programming Menu Conventions ‹ Descriptions Factory Default Value P.C. Programming Category SS : Signle scan selection MS : Multiple scans selection CS : Cycling scan selection DS : Dual level scan selection 3-9 ( ) Necessary Option Code [ ] Selectable Option Code Configure Your FuzzyScan Program & End System List, Group & Master Default Scan “SYSLIST” Scan “PROGRAM” FuzzyScan will list the product information and revision number to host via selected host interface, then issue the completion beeping (3 short beeps). FuzzyScan will enter programming mode, and inhibit all non-programming functions. Scan “M_DEFAULT” Scan “END” FuzzyScan will recover all programmable parameters into factory preset configurations, then issue the completion beeping (3 short beeps). FuzzyScan will exit programming mode, and store all parameters in Flash Memory ASIC or non-volatile memory, then issue the completion beeping (3 short beeps).  Please note that the FuzzyScan will take 3-4 seconds to store parameters in internal Flash Memory ASIC or non-volatile memory after you scan the “END”. Please don’t turn off the power before the completion beeping. It may destroy all configured parameters. Scan “G_DEFAULTxx” FuzzyScan will recover all programmable parameters of identified family group into factory preset configurations without changing other parameters, then issue the completion beeping.  The FuzzyScan is specially designed to provide several programming family groups. Each group has its own “Group Default” bar code system command. 3-10 Configure Your FuzzyScan Single scan selection Scan “PROGRAM” Multiple scans selection Scan “PROGRAM” Enter programming mode. Select one of desired Select one of desired Scan One of Family Codes Scan One of Family Codes programming families. programming families. 1. Select one or several Select one option code of Scan One of Option Codes Enter programming mode. Scan One or Several Option Codes desired parameter. option codes to select desired parameters. 2. If it’s necessary, scan “FIN” to terminate Yes Yes Want to select another Repeat Selection programming family? Repeat Selection option code selection. Want to select another No No Scan “END” Scan “END” Exit programming mode. 3-11 programming family? Exit programming mode. Configure Your FuzzyScan Dual level selection Cycling scan selection Scan “PROGRAM” Scan “PROGRAM” Scan One of Family Codes Enter programming mode. Select one of desired Scan One of Family Codes programming families. (1st) Scan Several Option Codes several option codes of desired parameters as “Single” or “Multiple” (2nd) Scan One or Several Option Codes Scan “FIN” Repeat Selection of desired parameters. 1. Select one or several parameters. 2. If it’s necessary, scan Finish cycling selection. “FIN” to terminate (If necessary) option code selection. Yes Want to select another Repeat Selection Want to select another programming family? programming family? No No Scan “END” programming families. option codes of desired scans selection. Yes Select one of desired Select several option codes Cycling select one or Scan One of Option Codes Enter programming mode. Scan “END” Exit programming mode. 3-12 Exit programming mode. Configure Your FuzzyScan Host Interface Selection ♦ FuzzyScan Gold, Jade & Diamond Series ♦ PROGRAM G_DEFAULT01 Family Code Selection P.C. Host Interface Selection MS IBM PC/XT, 286/XT keyboard wedge interface 00 MS IBM PC/AT, PS/1, PS/VP series keyboard wedge interface ‹ 01 MS IBM PS/2, 25-30 series keyboard wedge interface 02 MS IBM PS/2 30, 35-120 series keyboard wedge interface 03 Compaq, HP Vectra PC keyboard wedge interface 04 MS Apple ADB keyboard wedge interface 05 MS Standard/TTL RS-232 peer-to-peer serial interface 06 MS Standard/TTL RS-232 serial wedge interface 07 MS Wand emulation interface 08 MS Pseudo RS-232 serial interface (TTL level, 3-wire connection only) 09 MS PC/AT, PS/2 keyboard replacement interface (without external keyboard) 10 MS Cino Omnikey & VersaNet direct-link interface 11 MS HW-320 terminal keyboard wedge interface 12 MS General Notebook PC keyboard wedge interface (with external keybaord) 13 MS General Notebook PC keyboard direct-link interface (without external keyboard) 14 MS IBM SureOne keyboard wedge interface 15 MS IBM SureOne standard RS-232 serial interface 16 MS Laser emulation interface (TBD - Please check your vendor for the availability.) 17 MS USB keyboard interface (for Microsoft Windows 98 and NT) 18 MS IBM ThinkPad keyboard direct-link interface (without external pinpad) 84 MS IBM ThinkPad keyboard wedge interface (with external pinpad) 87 Š for Gold/Jade/Diamond series Š MS Parameter Selection ƒ All the above listed host interface selections are not available for FuzzyScan Lite series. ƒ All FuzzyScan Gold/Jade/Diamond series are factory defaulted as IBM PC/AT, PS/1, PS/VP keyboard wedge interface. ƒ USB keyboard interface is only upported by Windows 98, Windows NT 5.0 or above. 3-13 Option Code Configure Your FuzzyScan Host Interface Selection ♦ FuzzyScan Jade & Diamond Series ♦ PROGRAM G_DEFAULT01 Family Code Selection P.C. Host Interface Selection MS IBM PS/55 5576-001 (code set 81) keyboard wedge interface 70 MS IBM PS/55 5576-002 (code set 81) keyboard wedge interface 71 MS IBM PS/55 5576-003 (code set 81) keyboard wedge interface 72 MS IBM PS/55 5576-A01 (code set 1) keyboard wedge interface 73 MS IBM PS/55 5576-001 (code set 8A) keyboard wedge interface 74 MS IBM PS/55 5576-002 (code set 8A) keyboard wedge interface 75 MS IBM PS/55 5576-003 (code set 8A) keyboard wedge interface 76 MS IBM PS/V PC, 5576-001 (code set 82) keyboard wedge interface 77 MS IBM PS/V PC, 5576-002 (code set 82) keyboard wedge interface 78 MS IBM PS/V PC, 5576-003 (code set 82) keyboard wedge interface 79 MS IBM PS/V PC, 5576-A01 (code set 2) keyboard wedge interface 80 MS Hitachi Flora KB1100 keyboard wedge interface 81 MS Hitachi Flora KB3100 keyboard wedge interface 82 MS Compaq Desktop PC keyboard wedge interface 83 MS DOS/V keyboard direct link interface 85 MS Fujitsu FMV keyboard wedge interface 86 MS NEC NX Notebook direct link interface 89 MS NEC PC-98 keyboard wedge interface 90 Š for Jade & Diamond series Š Parameter Selection Option Code ƒ All of the above listed interfaces are not available for FuzzyScan Lite and Gold series. ƒ All of the above listed interfaces are specially for Japanese Machines. ƒ The Keyboard Wedge Interfaces of IBM/DEC/WYSE/TELEX, IBM 4683/4694 Traditional Interface and Variuos OCIA Interfaces are available with the FuzzyScan Diamond series only under OEM/ODM request. Please consult your local FuzzyScan vendor for details. 3-14 Configure Your FuzzyScan Symbology Reading Control ♦ User Defined Symbol ID ♦ PROGRAM G_DEFAULT09 Family Code Selection P.C. Symbol ID : 1 character DS Symbol ID : 2 character DS Parameter Selection Option Code 2nd Option Code Code 128 (default=B) 00 (1 character) UCC/EAN-128 (default=C) 01 (1 character) UPC-A (default=A) 02 (1 character) EAN/JAN/CAN-13 (default=F) 03 (1 character) Codabar/NW-7 (default=D) 04 (1 character) Code 39/Code 32 (default=G) 05 (1 character) Code 93 (default=H) 06 (1 character) Standard/Industrial 2 of 5 (default=I) 07 (1 character) Interleaved 2 of 5 (default=J) 08 (1 character) Matrix 2 of 5 (default=K) 09 (1 character) China Postal Code (default=L) 10 (1 character) German Postal Code (default=M) 11 (1 character) IATA (default=O) 12 (1 character) Code 11 (default=P) 13 (1 character) MSI/Plessey (default=R) 14 (1 character) UK/Plessey (default=S) 15 (1 character) Telepen (default=T) 16 (1 character) UPC-E (default=E0) 00 [1-2 characters], [FIN] EAN-8 (default=FF) 01 [1-2 characters], [FIN] 3-15 Configure Your FuzzyScan Symbology Reading Control ♦ Symbology ID Trans., Readable Bar Code Setting ♦ PROGRAM G_DEFAULT09 Family Code Selection P.C. Symbology ID Transmission SS Disable symbology ID transmission ‹ 0 SS Enable prefix symbology ID transmission 1 SS Enable suffix symbology ID transmission 2 SS Enable both prefix and suffix symbology ID transmission 3 SS Automatic discrimination ‹ 00 CS Code 128, UCC/EAN-128 01 CS UPC-A 02 CS UPC-E 03 CS EAN/CAN/JAN-13 04 CS EAN/CAN/JAN-8 05 CS Codabar/NW-7 06 CS Code 39/Code 32, HIBC 07 CS Code 25 Family, IATA 08 CS Code 93 09 CS Code 11 10 CS MSI/Plessey 11 CS UK/Plessey 12 CS Telepen 13 Readable Symbology Setting Remember to scan “FIN” to terminate this selection. But if you select the “ Automatic discrimination ”, FuzzyScan will terminate this selection automatically. Parameter Selection Option Code ƒ If your application is reading known, limited bar code symbologies, you may increase the reading speed and decrease the reading error possibility by selecting those known symbologies only. Furthermore, to add the “Symbology ID” into the transmitted data is also helpful for applications to identify the specific symbology ID. ƒ To further ensure fast, accurate readings, you can complete more complex configurations via full-feature DataWizard. To configure the full-feature DataWizard, user must use the PowerTool which is a Windows 95/98/NT based software utility specially designed for FuzzyScan Universal Interface Models (Gold, Jade and Diamond series). Please consult your local FuzzyScan vendor for details. 3-16 Configure Your FuzzyScan Symbology Reading Control ♦ Code 39/Code 32 Setting♦ PROGRAM G_DEFAULT09 Family Code Selection P.C. Code 39 Family Setting SS Select Standard Code 39 as primary format ‹ 0 SS Select Full ASCII Code 39 as primary format 1 SS Select Code 32 (Italian Pharmaceutical) as primary format 2 SS Disable start/stop symbol transmission ‹ 3 SS Enable start/stop symbol transmission 4 SS Disable Code 32 leading A transmission ‹ 5 SS Enable Code 32 leading A transmission 6 SS Disable MOD 43 check digit verification ‹ 7 SS Enable MOD 43 check digit verification 8 SS Disable check digit transmission 9 SS Enable check digit transmission ‹ A SS Default (04) ‹ MS 01-Maximum Code 39 Min. Length Parameter Selection Option Code FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Code 39 Max. Length SS Default (98) ‹ MS 98-Minimum FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. 3-17 Configure Your FuzzyScan Symbology Reading Control ♦ Codabar/NW-7 Setting ♦ PROGRAM G_DEFAULT09 Family Code Selection P.C. Codabar Setting SS Select Codabar standard format ‹ 0 SS Select Codabar ABC format 1 SS Select Codabar CLSI format 2 SS Select Codabar CX format 3 SS Disable start/stop symbol transmission ‹ 4 SS Enable ABCD/ABCD start/stop symbol transmission 5 SS Enable abcd/abcd start/stop symbol transmission 6 SS Enable ABCD/TN*E start/stop symbol transmission 7 SS Enable abcd/tn*e start/stop symbol transmission 8 SS Disable check digit verification ‹ 9 SS Enable check digit verification A SS Disable check digit transmission B SS Enable check digit transmission ‹ C SS Default (04) ‹ MS 01-Maximum Codabar Min. Length Parameter Selection Option Code FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Codabar Max. Length SS Default (98) ‹ MS 98-Minimum FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. 3-18 Configure Your FuzzyScan Symbology Reading Control ♦ UPC-A & UPC-E Setting ♦ PROGRAM G_DEFAULT09 Family Code Selection P.C. Parameter Selection Option Code UPC Family Setting SS Select UPC without supplement digits ‹ 0 SS Select UPC with only 2 supplement digits 1 SS Select UPC with only 5 supplement digits 2 SS Select UPC with 2/5 supplement digits 3 SS Disable UPC-E expansion ‹ 4 SS Enable UPC-E expansion 5 SS Disable UPC standardization ‹ 6 SS Enable UPC standardization 7 SS Disable UPC numeric system 8 SS Enable UPC numeric system ‹ 9 SS Disable UPC-A check digit transmission A SS Enable UPC-A check digit transmission ‹ B SS Disable UPC-E check digit transmission C SS Enable UPC-E check digit transmission ‹ D SS Disable UPC “leading 1” portion ‹ E SS Enable UPC “leading 1” portion F ƒ UPC-E & EAN-8 Expansion : Expand the 7-digit UPC-E and 8-digit ENA-8 to 12-digit UPC-A and 13-digit EAN-13. ƒ UPC-A/E Standardization : Expand the 7-digit UPC-E and 12-digit UPC-A to 8-digit UPC-8 to 13-digit EAN-13 with 1 zero insertion. ƒ UPC Lead 1 Numeric System : Enable to read UPC leading with the 1 numeric system, you must enable this option. WPC Selection (UPC/EAN/JAN/CAN) UPC-A UPC-E EAN/JAN/CAN-13 EAN/JAN/CAN-8 Basic Length 12 7 13 8 Disable Check Digit -1 -1 -1 -1 Disable Numeric System -1 -1 NC NC 3-19 With 2-digit Addendum +2 +2 +2 +2 With 5-digit Addendum +5 +5 +5 +5 Enable Standardization +1 +1 NC NC Enable Expansion 0 +5 0 +5 Configure Your FuzzyScan Symbology Reading Control ♦ EAN/JAN/CAN & IATASetting ♦ PROGRAM G_DEFAULT09 Family Code Selection P.C. EAN/CAN/JAN Setting SS Select EAN without supplement digits ‹ 0 SS Select EAN with only 2 supplement digits 1 SS Select EAN with only 5 supplement digits 2 SS Select EAN with 2/5 supplement digits 3 SS Disable EAN-8 expansion ‹ 4 SS Enable EAN-8 expansion 5 SS Disable EAN-13 check digit transmission 6 SS Enable EAN-13 check digit transmission ‹ 7 SS Disable EAN-8 check digit transmission 8 SS Enable EAN-8 check digit transmission ‹ 9 SS Disable ISBN/ISSN Conversion reading check ‹ A SS Enable ISBN/ISSN Conversion reading check B SS Select 15-digit fixed length IATA checking ‹ 0 SS Select variable length IATA 1 SS Disable check digit verification ‹ 2 SS Enable check digit automatic verification 3 SS Enable S/N checking digit verification only 4 SS Enable CPN checking digit verification only 5 SS Enable CPN, Airline and S/N check digit verification 6 SS Disable start/stop symbol transmission ‹ 7 SS Enable start/stop symbol transmission 8 SS Disable check digit transmission 9 SS Enable check digit transmission ‹ A IATA Setting Parameter Selection 3-20 Option Code Configure Your FuzzyScan Symbology Reading Control ♦ Code 25 Family & German Post Code Setting ♦ PROGRAM G_DEFAULT09 Family Code Selection P.C. Code 25 Setting SS SS SS SS SS SS SS Select any Code 25 ‹ Select Standard/Industrial 2 of 5 only Select Matrix 2 of 5 only Select Interleaved 2 of 5 only Select Interleaved 2 of 5 S Code only Select IATA only Select China Postal Code only 0 1 2 3 4 5 6 SS SS Disable check digit verification ‹ Enable check digit verification 7 8 SS SS Disable check digit transmission Enable check digit transmission ‹ 9 A SS Default (06) ‹ MS 01-Maximum Code 25 Min. Length Parameter Selection Option Code FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Code 25 Max. Length SS Default (98) ‹ MS 98-Minimum FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. German Postal Setting SS Disable ‹ 0 SS Enable 1 ƒ The FuzzyScan can decode almost all Code 25 symbologies automatically. But we recommend that you select only one kind of Code 25 for reading, or set limited maximum and minimum reading length for reading, because the encoding algorithm of Code 25 isn’t very good. To decode all Code 25 automatically or to read variable length Code 25 will increase the error reading rate. 3-21 Configure Your FuzzyScan Symbology Reading Control ♦ Code 11 & Code 93 Seting ♦ PROGRAM G_DEFAULT09 Family Code Selection P.C. Code 11 Setting SS Select 1-check digit verification 0 SS Select 2-check digit verification ‹ 1 SS Disable check digit transmission ‹ 2 SS Enable 1-check digit transmission 3 SS Enable 2-check digit transmission 4 SS Default (04) ‹ MS 01-Maximum Code 11 Min. Length Parameter Selection Option Code FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Code 11 Max. Length SS Default (98) ‹ MS 98-Minimum FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Code 93 Setting SS SS Disable check digit transmission ‹ Enable check digit transmission Code 93 Min. Length SS Default (03) ‹ MS 01-Maximum 0 1 FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Code 93 Max. Length SS Default (98) ‹ MS 98-Minimum FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. 3-22 Configure Your FuzzyScan Symbology Reading Control ♦ MSI/Plessey, Code 128 & UCC/EAN 128 Setting ♦ PROGRAM G_DEFAULT09 Family Code Selection P.C. MSI/Plessey Setting SS Select MOD 10 check digit ‹ 0 SS Select MOD 10-10 check digit 1 SS Select MOD 11-10 check digit 2 SS Disable check digit transmission 3 SS Enable 1-check digit transmission ‹ 4 SS Enable 2-check digit transmission 5 SS Default (04) ‹ MS 01-Maximum MSI/Plessey Min. Length Parameter Selection Option Code FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. MSI/Plessey Max. Length SS Default (98) ‹ MS 98-Minimum FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Code 128/EAN-128 Setting Code 128/EAN-128 Min. Length SS Disable function code conversion ‹ 0 SS Enable function code conversion 1 SS Default (04) ‹ MS 01-Maximum FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Code 128/EAN-128 Max. Length SS Default (98) ‹ MS 98-Minimum FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. 3-23 Configure Your FuzzyScan Symbology Reading Control ♦ UK/Plessey & Telepen Setting ♦ PROGRAM G_DEFAULT09 Family Code Selection P.C. UK/Plessey Setting SS Select UK/Plessey Standard Format ‹ 0 SS Select UK/Plessey CLSI Format 1 SS Disable Convert X to A-F ‹ 2 SS Enable Convert X to A-F 3 SS Disable check digit transmission ‹ 4 SS Enable check digit transmission 5 SS Default (04) ‹ MS 01-Maximum Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. SS Default (98) ‹ MS 98-Minimum Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. SS Select Telepen Numeric mode ‹ 0 SS Select Telepen Full ASCII mode 1 SS Disable check digit transmission ‹ 2 SS Enable check digit transmission 3 SS Default (04) ‹ MS 01-Maximum Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. SS Default (98) ‹ MS 98-Minimum Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. UK/Plessey Min. Length UK/Plessey Max. Length Telepen Setting Telepen Min. Length Telepen Max. Length Parameter Selection Option Code FIN (2 digits) FIN (2 digits) FIN (2 digits) FIN 3-24 (2 digits) Configure Your FuzzyScan Keyboard Interface Control ♦ Keyboard Layout (Language) Setting ♦ PROGRAM G_DEFAULT02 Family Code Selection P.C. Keyboard Layout MS USA (QWERTY) ‹ 00 MS France (AZERTY) 01 MS Germany (QWERTZ) 02 MS United Kingdom - UK (QWERTY) 03 MS Canadian French (QWERTY) 04 MS Spain (QWERTY) 05 MS Sweden/Finland (QWERTY) 06 MS Portugal (QWERTY) 07 MS Norway (QWERTY) 08 MS Latin America (QWERTY) 09 MS Italy (QWERTY) 10 MS Netherlands (QWERTY) 11 MS Denmark (QWERTY) 12 MS Belgium (AZERTY) 13 MS Switzerland-Germany (QWERTY) 14 MS Iceland (QWERTY) 15 MS Universal (only available for IBM PC/AT, PS/VP in MS DOS and Windows Mode) 99 The “Universal Selection” is only for PC/AT, PS/VP, PS/2 and compatible ones in DOS or Windows environment which can perform unique output without Caps Lock on/off (Output Style) concern. All transmitted data will follow the original full ASCII form. You also need not worry about the upper/lower case control. Parameter Selection Option Code ƒ Please refer to the ASCII/HEX Table listed in the Appendix to determine HEX codes for characters, symbols, and functions to be used as premble or postamble. ƒ To set preamble or postamble as function key output, you must enable the “Function Key Emulation” feature as listed in page 3-25 first. ƒ Keyboard Interface Message String : Preamble Data Length Prefix Symbol ID Scanned Data Suffix Symbol ID Postamble Record Suffix 1-15 characters 2-3 digits 1 or 2 characters variable length 1 or 2 characters 1-15 characters 1 character 3-25 Configure Your FuzzyScan Keyboard Interface Control ♦ Record Suffix, Preamble, Postamble & Delay Setting ♦ PROGRAM G_DEFAULT02 Family Code Selection P.C. Record Suffix SS None 0 SS RETURN‹ 1 SS TAB 2 SS SPACE 3 SS ENTER (Numeric Key Pad) 4 MS User defined character (1 character) SS None ‹ MS 1-15 characters Preamble Parameter Selection Option Code 5, (00-7F) FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection. Postamble SS None ‹ MS 1-15 characters FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection. Character Frame Control SS None ‹ MS 1-99 msec. FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Intermessage Delay SS None ‹ MS 1-99 (x5) msec. FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Intercharacter Delay SS None ‹ MS 1-99 msec. FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. 3-26 Configure Your FuzzyScan Keyboard Interface Control ♦ Caps Lock Control & Emulation Setting ♦ PROGRAM G_DEFAULT02 Family Code Selection P.C. Caps Lock Control SS “Caps Lock Off” State ‹ 0 SS “Caps Lock On” State 1 SS Auto Detect (PC/AT, PS/2, Keyboard Replacement and DOS/V Machines only) 2 SS Enable ASCII 00-31 code as keyboard function code output ‹ 0 SS Ctrl-Output 1 Function Key Emulation Parameter Selection Option Code Refer to Appendix – Keyboard Function Code Table for details. Key Pad Emulation Upper/Lower Case SS Disable key pad emulation ‹ 0 SS Enable numeric output as key pad (Num Lock On) output 1 SS Normal case (neglect the upper/lower case control) ‹ 0 SS Inverse case (change all characters output to inverse case) 1 Upper case (force all characters output as upper case) 2 Lower case (force all characters output as lower case) 3 ƒ Character Frame Control is used to adjust timing gap between bytes within one character data output by FuzzyScan. Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safty margin when adjusting these two parameters. ƒ Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time. ƒ The function of “Caps Lock Control” and “Key Pad Emulation” are only available for IBM PC/AT, PS/VP, PS/2 series personal computers and compatible machines. While selecting the other host interfaces, these selections don’t perform the above functions for you. ƒ Please check the actual Caps Lock stste in use while software application is running. If the Caps Lock stste is off, select “Caps Lock Off” state, then FuzzyScan will perform normal data transmission. If the Caps Lock state is on, select “Caps Lock On” state. Select “Auto Detect”, FuzzyScan will perform special transmission handshaking without changing the status of Caps Lock switch. 3-27 Configure Your FuzzyScan Serial Interface Control ♦ Record Suffix, Handshaking & Time Out Setting ♦ PROGRAM G_DEFAULT03 Family Code Selection P.C. Parameter Selection Option Code STX/ETX Control SS Disable STX/ETX transmission ‹ 0 SS Enable STX/ETX transmission 1 STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface. Record Suffix Preamble SS None 0 SS CR (0DH) ‹ 1 SS LF (0AH) 2 SS CRLF (0D0AH) 3 SS TAB (09H) 4 SS SPACE (20H) 5 SS EOT (04H) 6 MS User defined character (1 character) SS None ‹ MS 1-15 characters 7, (00-7F) FIN [00-7F],[FIN] Maximum 15-character input; scan “FIN” to terminate this selection. Postamble SS None ‹ MS 1-15 characters FIN [00-7F],[FIN] Maximum 15-character input; scan “FIN” to terminate this selection. ƒ Serial Interface Message String : STX Preamble Data Length 1 character 1-15 characters 2-3 digits Prefix Symbol ID Scanned Data Suffix Symbol ID Postamble 1 or 2 characters variable length 1 or 2 characters 1-15 characters 3-28 ETX Record Suffix 1 character 1 character Configure Your FuzzyScan Serial Interface Control ♦ Baud Rate & Data Frame Setting ♦ PROGRAM G_DEFAULT03 Family Code Selection P.C. Handshaking Protocol SS None (free running mode) ‹ 0 SS RTS/CTS (hardware handshaking) 1 SS ACK/NAK (software handshaking) 2 SS Xon/Xoff (software handshaking) 3 SS 38.4K BPS 2400 BPS 0 4 SS 19.2K BPS 1200 BPS 1 5 SS 9600 BPS ‹ 600 BPS 2 6 SS 4800 BPS 300 BPS 3 7 SS 8, None, 1 ‹ 7, Space, 1 0 8 SS 8, Odd, 1 7, Mark, 1 1 9 SS 8, Even, 1 7, None, 2 2 A SS 8, Space, 1 7, Odd, 2 3 B SS 8, Mark, 1 7, Even, 2 4 C SS 8, None, 2 7, Space, 2 5 D SS 7, Odd, 1 7, Mark, 2 6 E SS 7, Even, 1 SS None 1 second 0 3 SS 200 mseconds 2 seconds 1 4 SS 500 mseconds ‹ 5 seconds 2 5 Baud Rate (BPS) Data Frame Time Out Control Parameter Selection Option Code 7 User defined value (seconds) MS 6, (2 digits) ƒ When the RTS/CTS Hardware Handshaking option is selected, the RTS (request to send) and CTS (clear to send) signals will be issued before normal data communication. This option is very helpful to ensure the reliability of data communication. ƒ When the ACK/NAK Software Handshaking option is selected, the FuzzyScan waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after each data transmission. If the NAK is received, FuzzyScan will re-send the data until receiving ACK. ƒ TheTime Out Control is a pre-defined delay time for FuzzyScan to wait for handshaking, acknowledgment or non-acknowledgment from the host computer. 3-29 Configure Your FuzzyScan Wand Emulation Control ♦ Output Polarity, Singal State, Margin/Module Time, etc.♦ PROGRAM G_DEFAULT04 Family Code Selection P.C. Parameter Selection Option Code Output Polarity SS High level (5Vdc) on Bar (low level on Space) ‹ 0 SS Low level (0Vdc) on Bar (high level on Space) 1 Determine the output voltage level for both bar and space. Initial Signal State SS High Level (5Vdc) ‹ 0 SS Low Level (0Vdc) 1 Determine the initial state of output voltage level. Margin Time Module Time Narrow/Wide Ratio Code 39 Emulation SS 10 mseconds 30 mseconds 0 4 SS 15 mseconds 50 mseconds 1 5 SS 20 mseconds ‹ 2 6 SS 25 mseconds 100 mseconds Delay time before data transmission SS 200 useconds 2.0 mseconds 0 4 SS 300 useconds 3.0 mseconds 1 5 SS 500 useconds ‹ 3 2 Time base of minimum narrow bar SS 1.0 mseconds 3 SS 1:2 ‹ 0 SS 1:2.5 1 SS 1:3 2 SS Disable standard Code 39 emulation ‹ 0 SS Enable standard Code 39 skip emulation 1 SS Enable standard Code 39 replace emulation 2 ƒ [ Code 39 Skip ] : When this option is selected, all scanned data will be translated as Standard Code 39 wand emulation output. If any lower case characters are read, they will be translated to upper case characters. Any other characters that are not available in Code 39 symbology set will be skipped. ƒ [ Code 39 Replace] : Any character not normally available in the standard Code 39 symbology set, will be translated as Space. 3-30 Configure Your FuzzyScan OCIA, IBM 4683/4694 Interface ♦ OCIA & IBM 4683/4694 Interface Setting ♦ PROGRAM G_DEFAULT05 Family Code Selection P.C. IBM 4683/4694 I/O Port SS Port 5B 0 SS Port 9B ‹ 1 SS Port 17 2 SS NCR-S-format 0 SS NCR-F-format 1 SS DTS/Nixdorf 2 SS Siemens 3 SS Spectra Physics ‹ 4 SS TEC 5 SS CASIO 6 OCIA Output Format Parameter Selection Option Code ƒ These special interfaces are only available for OEM/ODM. Due to varieties on data format, pin-assignment, and connector type in the market, please prepare related information and check with the manufacturer first to verify compatibility. Quantity commitment is necessary on these models. 3-31 Configure Your FuzzyScan Operation Control ♦ Operation Mode, Buzzer Tone, Dollar Sign ♦ PROGRAM G_DEFAULT06 Family Code Selection P.C. Operation Mode SS Low Power mode (Low Power triggering) 0 SS Trigger mode (External triggering) ‹ 1 SS Level mode (Auto power off) 2 SS Alternative mode (Periodic power off) 3 SS Flash mode (Pulse driven reading) 4 SS Force mode (Continued power on) 5 SS Toggle mode (Repeat reading) 6 SS Diagnostic mode (Test reading) 7 SS Buzzer tone - mute 0 SS Buzzer tone - low 1 SS Buzzer tone - medium ‹ 2 SS Buzzer tone - high 3 SS Buzzer tone - extremely high 4 SS Good-read beep before data transmission ‹ 5 SS Good-read beep after data transmission 6 SS Power-on beep ‹ 7 SS No power-on beep 8 SS Regular (standard) printing quality ‹ 0 SS Poor (critical) printing quality 1 Buzzer Tone Adjust Scanning Tolerance (Printing Quality Control) Parameter Selection Please note that if you select “Poor printing quality”, you should limit “Readable Bar Code Symbology” and “Minimum & Maximum Reading Length” of each symbology to avoid error reading. ƒ For FuzzyScan Laser scanners, the FBL-series , only Low Power mode and Trigger mode are available. ƒ The “Scanning Tolerance” is specially designed for the most popular symbologies such as Code 39, UPC and EAN. 3-32 Option Code Configure Your FuzzyScanu Operation Control ♦ Scanning Tolerance, Double Scan Verification ♦ PROGRAM G_DEFAULT06 Family Code Selection P.C. Double Scan Verification SS Disable Long time out duration 0 4 SS Immediate time out duration Force Verification 1 5 SS Short time out duration ‹ 2 SS Medium time out duration 3 SS None 4 times 0 4 SS 1 time 5 times 1 5 SS 2 times ‹ 2 SS 3 times 3 SS Short (around 2 seconds) 0 SS Medium (around 3-4 seconds) 1 SS Long (around 5-6 seconds) 2 SS Extremely long (around 7-8 seconds) ‹ 3 SS 1/2 duty cycle ‹ 0 SS 2/3 duty cycle 1 SS 3/4 duty cycle 2 SS 4/5 duty cycle 3 SS None ‹ 120 mseconds 0 4 SS 20 mseconds 150 mseconds 1 5 SS 50 mseconds 200 mseconds 2 6 SS 100 mseconds 250 mseconds 3 7 SS Dollar sign as “$” ‹ 0 SS Dollar sign as “¥” 1 Redundancy (Scan Voting) Auto Power Off Duration Pulse Driven Duty Dubunce Time Control Dollar Sign Control Parameter Selection This parameter is used to set up the dollar sign output as Japanese Yen or standard dollar sign. ƒ The “Double Scan Verification” is designed to inhibit FuzzyScan from reading the same bar code label twice in pre-defined short duration. ƒ The Redundancy is the number of times the same bar code label has to be decoded before it is transmitted. 3-33 Option Code Configure Your FuzzyScan Condensed DataWizard ♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦ PROGRAM G_DEFAULT07 Family Code Selection P.C. Parameter Selection Preamble SS None ‹ MS 1-15 characters Option Code FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection. Postamble SS None ‹ MS 1-15 characters FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection. Data Length Transmission SS Disable ‹ 0 SS Enable 2-digits data length transmission 1 If data length exceeds 99, 3-digit data length will be transmitted. Symbology ID Transmission SS Disable symbol ID transmission ‹ 0 SS Enable prefix symbol ID transmission 1 SS Enable suffix symbol ID transmission 2 SS Enable both prefix and suffix symbol ID transmission 3 ƒ DataWizard is the most powerful, Artificial-Intelligence based data editing expert system provided specially for the FuzzyScan family bar code readers, OmniKey Premium I/O-oriented POS keyboards, and VersaNet transaction terminals. Through DataWizard, you can process the scanned data prior the transmissions in many ways as: Insert, Delete, Match, Verify, Replace, Reorganize, and Repeat Transmission. It will help you to arrange the transmission of scanned data to any specific format without software modification. ƒ Due to the resources used by this system, Full-feature DataWizard is only supported by PowerTool and not available on the FuzzyScan Lite series. Through the PowerTool, all settings and configurations can be done on-screen, under Windows 95/98/NT environment. ƒ A Condensed Version DataWizard is provided by each FuzzyScan scanner including Lite series. Through this menu, the condensed DataWizard can be utilized via bar code menu readings with ease. ƒ Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value. ƒ If you have any problem to use DataWizard, please refer to following pages for details and consult your local FuzzyScan vendor or our web site for any assistance. 3-34 Configure Your FuzzyScan Condensed DataWizard ♦ Data Formater Setting ♦ PROGRAM G_DEFAULT07 Family Code Selection P.C. Formatter Control SS Disable ‹ MS Select one bar code symbology (2 digits) MS Select all bar code symbologies 00 SS Disable ‹ DS Enable 1st Insertion Parameter Selection SS Disable ‹ DS Enable SS Disable ‹ DS Enable SS Disable ‹ DS Enable [1-3 characters], [FIN] position FIN (2 digits) [1-3 characters], [FIN] position FIN (2 digits) 2-digits identified position; max. 3 insertion characters 4th Insertion automatic termination automatic termination FIN (2 digits) 2-digits identified position; max. 3 insertion characters 3rd Insertion 2nd Option Code FIN 2-digits identified position; max. 3 insertion characters 2nd Insertion Option Code [1-3 characters], [FIN] position FIN (2 digits) 2-digits identified position; max. 3 insertion characters [1-3 characters], [FIN] position ƒ The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for formatter control, and provides Multiple Position Insertion and Multiple Character Insertion (max three characters) in the identified position. ƒ While the Data Formatter is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbolology ID or Record Suffix. All of the above programmable parameters perform the same function depending on your setting. ƒ Regarding the “Bar Code Selection” and “Position Calculation” of data formatter, please refer to page 3-37 for details. ƒ Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value. 3-35 Configure Your FuzzyScan Condensed DataWizard ♦ Data Verifier Setting ♦ PROGRAM G_DEFAULT07 Family Code Selection P.C. Verifier Control SS Disable ‹ MS Select one bar code symbology (2 digits) automatic termination MS Select all bar code symbologies 00 automatic termination SS Disable ‹ MS Enable Identified Data Length Parameter Selection Option Code 2nd Option Code FIN FIN (2 digits) Determine the identified data length for verification. 1st Identified Character SS Disable ‹ DS Enable FIN (2 digits) 2-digits checking position; 1 identified character 2nd Identified Character SS Disable ‹ DS Enable SS Disable ‹ DS Enable position FIN (2 digits) 2-digits checking position; 1 identified character 3rd Identified Character [00-7F] [00-7F] position FIN (2 digits) 2-digits checking position; 1 identified character [00-7F] position ƒ The Data Verifier is used to provide advanced verification for error-free scanning and to work as an Embedded Data Transmitting Filter. ƒ All data must conform to the Identified Bar Code Symbologies, Identified Data Length, and one to three Identified Characters in the checking position. Otherwise, the FuzzyScan will not transmit the data to the host computers or terminals, but will instead issue 3 long beeps for verification error and skip the scanned data. ƒ The Data Verifier checks only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix. ƒ Regarding the “Bar Code Selection” and “Position Calculation” of Data Verifier, please refer to page page 3-37 for details. ƒ Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value. 3-36 Configure Your FuzzyScan Condensed DataWizard ♦ Data Replacer Setting ♦ PROGRAM G_DEFAULT07 Family Code Selection P.C. Replacer Control SS Disable ‹ MS Select one bar code symbology (2 digits) automatic termination MS Select all bar code symbologies 00 automatic termination SS Disable ‹ DS Enable 1st Replacement Parameter Selection SS Disable ‹ DS Enable FIN (2 digits) SS Disable ‹ DS Enable [ 00-7F ] position FIN (2 digits) 2-digits identified position; 1 replacement character 3rd Replacement 2nd Option Code FIN 2-digits identified position; 1 replacement character 2nd Replacement Option Code [ 00-7F ] position FIN (2 digits) 2-digits identified position; 1 replacement character [ 00-7F ] position ƒ The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for replacer control, and provides Multiple Position Replcement in the identified position. ƒ All data must conform to the Identified Bar Code Symbologies, and one to three Identified Characters in the identified position While the Data Replacer is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix. ƒ Regarding the “Bar Code Selection” and “Position Calculation” of Data Replacer, please refer to page 3-37 for details. ƒ Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find mathced HEX value. 3-37 Configure Your FuzzyScan Condensed DataWizard ♦ Data Organizer Setting ♦ PROGRAM G_DEFAULT07 Family Code Selection P.C. Organizer Control SS Disable ‹ MS Select one bar code symbology (2 digits) automatic termination MS Select all bar code symbologies 00 automatic termination SS Disable ‹ DS Enable (2 digits) 2-digits identified position; Forward/backward data transmission setting position direction 1st Organization 2nd Organization Include/Exclude Control Parameter Selection Option Code 2nd Option Code FIN FIN SS Disable ‹ DS Enable (2 digits) 2-digits identified position; Forward/backward data transmission setting position direction 0 (Forward) ‹ 1 (Backward) FIN SS Transmitted data excluded the data of identified position‹ 0 DS Transmitted data included the data of identified position 1 0 (Forward) ‹ 1 (Backward) ƒ The Data Organizer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for organizer control, and provides maximum two identified positions to send the data forward or backward. It also allows you to control the transmitted data including or excluding the data of identification position. Please refer to the application example listed in page 3-38 for details. ƒ While the Data Organizer is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix. ƒ Reagrding the “Bar Code Selection” and “Position Calculation” of Data Organizer, please refer to page 3-37 for details. ƒ Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix. 3-38 Configure Your FuzzyScan Select a Bar Code Symbology Application Example You can select one or all types of bar code symbologies to use Condensed DataWizard for advanced transmission arrangement. If you scan “00” to select all types, the FuzzyScan will arrange all incoming data to meet your pre-defined format. if you want to select only one type bar code, please select one of the option code listed below. If your bar code label is a 16-digit Interleaved 2 of 5 which includes the information of 6-digit date code, 6-digit serial number and 4-digit unit price, you want the FuzzyScan do the following for you without software modification: UPC-E : 03 UPC-A : 02 EAN/CAN/JAN-8 : 05 EAN/CAN/JAN-13 : 04 Code 32 : 07 Telepen : 13 Code 128 : 01 UCC/EAN 128 : 01 Code 39 : 07 Code 93 : 09 ƒ Apply only Interleaved 2 of 5 to the condensed DataWizard. ƒ Check bar code is actually with 16-digit length. Codabar/NW-7 : 06 Code 25 Family : 08 Code 11 : 10 UK/Plessey : 12 MSI/Plessey : 11 ƒ Allow bar code output whose date code is leading with “9”. ƒ Three outputs with “TAB” suffix. ƒ The date code output should skip “9” and replaced it by “A”. ƒ The serial number output should be led with “SN”. Position Calculation ƒ The unit price output should be skipped the first 2 digits. [Data Formatter] ƒ Test Bar Code : 9 8 1 0 2 5 1 2 3 4 5 6 9 8 7 6 If there is a 5-character input data string, refer to the following to calculate the actual position for insertion: ƒ Actual Output : A81025[TAB]SN123456[TAB]76[TAB] X 00 X 01 X 02 X 03 Programming Procedure X 04 [Data Verifier] 05 [Data Verifier, Data Replacer, Data Organizer] ƒ Scan “Program” to enter the programming mode. If there is a 11-character data string, please refer to the following to calculate the actual position for identification. ƒ Scan “Verifier Control” and set bar code symbology to “08” (Interleaved 2 of 5). X X X X X X X X X X X ƒ Scan “Identified Data Length” and set the length to “16”. 00 01 02 03 04 05 06 07 08 09 10 ƒ Scan “1st Identified Character” and set the identified position to “00”, then set the identified character to “39” (Hex Code of 9). 3-39 Configure Your FuzzyScan [Data Formatter] [Important Notice] ƒ Scan “Formatter Control” and set bar code symbology to “08”. Please note that Condensed DataWizard will follow the preset working flow as below: ƒ Scan 1st Insertion” and set the identified position to “06”, then inserted characters to “09” (Hex Code of TAB), “53” (Hex Code of S), “4E” (Hex Code of N). Verifier  Formatter  Replacer  Organizer So when you set the identified position in Data Organizer, you must consider the inserted data which you already set via Data Formatter. ƒ Scan “2nd Insertion” and set the identified position to “12”, then inserted character to “09”. In the final, you must scan “FIN” (Finish) code to terminate this selection. ƒ Scan “3rd Insertion” and set the identified position to “16”, then inserted character to “09”. In the final, you must scan “FIN” (Finish) code to terminate this selection. [Data Replacer] ƒ Scan “Replacer Control” and set bar code symbology to “08”. ƒ Scan “1st Replacement” and set the identified position to “00”, then replaced character to “41” (Hex Code of A). [Data Organizer] ƒ Scan “Organizer Control” and set bar code symbology to “08”. ƒ Scan “1st Organization” and set the identified position to “16”, then set the data transmission to “0” (forward). ƒ Scan “2nd Organization” and set the identified position to “17”, then set the data transmission to “1” (backward). ƒ Scan “END” (Exit) to terminate the programming. 3-40 Appendix Appendix This chapter gives the most updated illustration on all FuzzyScan family accessories including Various Host Interface Cable Converters, Power Adapters, Power-stealer Cables, Buzzer Beeping Indications, Keyboard Function Code Table, and so on. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding Also, all necessary bar code commands are printed in the fold out of the back cover of this manual. Please take special care on those pages for future programming purpose. If those pages are lost or damaged, please ask your local vendor for help. For accessory updated information, please consult with your local FuzzyScan vendor or visit our web site at: http://www.htz.com.tw A-1 Appendix please consult your vendor for details. Interface Cable Converters It’s not necessary for the FuzzyScan Lite series scanner to use any cable converter, because it comes with a main cable with dedicated suitable connectors. The following just covers information of most popular Cable Converters including: ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ PC/AT Keyboard Wedge Cable Converter PS/2 Keyboard Wedge Cable Converter PC/AT and PS/2 Keyboard Wedge Combo Cable Converter General Notebook PC (PS/2) Direct Link Cable Converter USB Type A/B Direct Link Cable Converter APPLE ADB Keyboard Wedge Cable Converter Power MAC Keyboard Wedge Cable Converter IBM ThinkPad Keyboard Wedge Cable Converter IBM ThinkPad Direct Link Cable Converter NEC 98xx Keyboard Wedge Cable Converter RS-232 Serial Interface Cable Converter RS-232 Serial Wedge Cable Converter Please note that the Interface Cable Converter only can be used with FuzzyScan Gold, Jade and Diamond series scanners which provide the Universal Linking Interface. If you need other interface cable converters not listed here (e.g. IBM SureOne RS-232 Serial Interface Cable Converter), A-2 Appendix Illustration Description P/N: CCA000100B PC/AT KB Wedge Cable Converter - Desktop PC/AT KB Wedge - 5P DIN Male & Female Connectors P/N: CCA000200B PS/2 KB Wedge Cable Converter - PS/2 KB Wedge - DOS/V KB Wedge - 6P Mini-DIN M&F Connectors P/N: CCA002200A Combo KB Wedge Cable Converter - Desktop PC/AT KB Wedge - PS/2 & DOS/V KB Wedge - 5P DIN & 6P Mini-DIN Connectors - Slave Cable included P/N: CCA002000A USB KB Cable Converter - USB KB Direct Link - 4P USB Type B Male Connector Minimum Quantity Required P/N: CCA001900A USB KB Cable Converter - USB KB Direct Link - 4P USB Type A Male Connector A-3 Appendix Illustration Description Illustration Description P/N: CCA001700A P/N: CCA000600A Apple ADB Keyboard Wedge Cable Converter RS-232 Serial Cable Converter - 4P Mini-DIN M&F Connectors - RS-232 Peer-to-Peer Interface - 25P D-Sub Female Connector - Embedded Power Jack P/N: CCA000300A P/N: CCA000400A Apple PowerMac ADB Keyboard Wedge Cable Converter RS-232 Serial Cable Converter - 4P Mini-DIN M&F Connectors - RS-232 Peer-to-Peer Interface - 9P D-Sub Femal Connector - Embedded Power Jack P/N: CCA001300A P/N: CCA000800A NEC 98xx Keyboard Wedge Cable Converter RS-232 Serial Wedge Cable Converter - 8P Mini-DIN M&F Connectors - 25P D-Sub M&F Connectors - Embedded Power Jack P/N: CCA001200A P/N: CCA001000B IBM ThinkPad Direct Link Cable Converter Notebook PS/2 Keyboard Direct Link Cable Converter - 6P Mini-DIN Male Connector - 6P Mini-DIN Male Connector P/N: CCA001100A P/N: CCA002100A IBM ThinkPad Keyboard Wedge Cable Converter Wand Emulation Interface Cable Converter - 6P Mini-DIN M&F Connectors - 9P D-Sub Female Connector A-4 Appendix AC Power Adapters Power-stealer Cable FuzzyScan only can accept the Regulated 5VDC inlet. If you hope to acquire an AC power adapter locally, please ensure the Outlet of the AC power adapters is Regulated 5VDC. For all power adapters not listed below, you are encouraged to use the power-stealer cables to take power from the keyboard port of your PC system. The Power-stealer Cable is specially designed to provide the Regulated 5VDC outlet directly from Keyboard Port, and still allows the keyboard to work with host machine. Illustration For most RS-232 serial applications, the host machines didn’t provide the direct power source. If your host computers do have the compatible PC/AT or PS/2 keyboard port, you are encouraged to use one of the following Power-stealer Cables for convenience. Description P/N: PAU000100A 110VAC AC Power Adapter Illustration - 110VAC Inlet - Regualted 5VDC Outlet - USA Type Connector Description P/N: CSO003611A PC/AT KB Power Stealer Cable - Compatible with PC/AT Keyboard - 5P DIN M/F Connectors - 90° DC Power Jack P/N: PAU000210A 230VAC AC Power Adapter - 220VAC Inlet - Regulated 5VDC Outlet - German Type Connector P/N: CSO003811A P/N: PAU000220A - Compatible with PS/2 Keyboard - 6P Mini DIN M/F Connectors - 90° DC Power Jack PS/2 KB Power Stealer Cable 240VAC AC Power Adapter - 240VAC Inlet - Regulated 5VDC Outlet - UK Type Connector A-5 Appendix Beeping Indications No. Descriptions Beeping Buzzer Tone 01 Internal or operation memory error Repeated beeps medium 02 Internal fatal error Repeated beeps medium 03 Beginning the normal operation 2 short beeps high + low 04 Entering the programming mode (Program) 3 short beeps high + low + low 05 Exiting the programming mode (End) 1 short beep medium 06 Completing to store the parameters 3 short beeps low + medium high 07 Starting the master default and group default 4 short beeps high medium + high + medium 08 Completing the master default and group default 3 short beeps low + high + low 09 Completing the system information listing 3 short beeps medium + high + medium 10 Good reading 1 short beep adjustable tone 11 Programming error (Invalid programming scan) 1 long beep medium 12 Scanning “FIN” to finish programming selection 2 short beeps medium + medium 13 Finishing the programming selection automatically 2 short beeps medium + medium 14 Data verifier checking error 3 long beeps medium + medium + medium 15 Memory buffer full 4 long beeps medium + medium + medium + medium 16 Time out warning 2 long beeps medium + medium 17 No CTS signal warning 1 long beep medium 18 Record over-size warning 1 long beep low A-6 Appendix Keyboard Function Code Table No. ANSI ASCII 00 NUL 00H 01 SOH 02 Key Function No. ANSI ASCII Key Function RESERVED 16 DLE 10H F7 01H CTRL (Left) 17 DC1 11H F8 STX 02H ALT (Left) 18 DC2 12H F9 03 ETX 03H SHIFT 19 DC3 13H F10 04 EOT 04H CAPS LOCK 20 DC4 14H CTRL (Right) 05 ENQ 05H NUM LOCK 21 NAK 15H ALT (Right) 06 ACK 06H ESC 22 SYN 16H INS (Insert) 07 BEL 07H F1 23 ETB 17H DEL (Delete) 08 BS 08H BS (Back Space) 24 CAN 18H HOME 09 HT 09H TAB 25 EM 19H END 10 LF 0AH F2 26 SUB 1AH PAGE UP 11 VT 0BH F3 27 ESC 1BH PAGE DOWN 12 FF 0CH F4 28 FS 1CH UP 13 CR 0DH ENTER (Carriage Return) 29 GS 1DH DOWN 14 SO 0EH F5 30 RS 1EH LEFT 15 SI 0FH F6 31 US 1FH RIGHT  To emulate the keyboard function key input for user definable parameters, user must configure actual content using the Reserved ASCII 0 – 31 characters, and also Enable the “Function Key Emulation”. Otherwise, the Ctrl ouput will be done by the scanner. Please refer to the above Keyboard Function Code Table which is for IBM PC/XT/AT, PS/2, PS/VP, COMPAQ PC, HP Vectra PC, Notebook PC, APPLE and PowerMac, and WYSE PC Enhanced or fully compatible machines. A-7 Appendix ASCII Input Shortcut HEX/ASCII Reference Table To configure the user definable parameters of FuzzyScan via programming menu, FuzzyScan will ask you to scan your desired ASCII value in HEX form. You have to refer to the “HEX/ASCII Table” for details. 0 1 2 3 4 5 6 7 0 NUL DLE SPACE 0 @ P ` p 1 SOH DC1 ! 1 A Q a q Example: 2 STX DC2 " 2 B R b r If you want the scanned data output leading with a Dollar Sign, you have to set the “Preamble” to “$”. The configuration procedure is listed below for reference. 3 ETX DC3 # 3 C S c s 4 EOT DC4 $ 4 D T d t 5 ENQ NAK % 5 E U e u 6 ACK SYN & 6 F V f v 7 BEL ETB ' 7 G W g w 8 BS CAN ( 8 H X h x 9 HT EM ) 9 I Y i y ƒ Refer to the Hex/ASCII Table, you will find the HEX value of “$” is 24. A LF SUB * : J Z j z B VT ESC + ; K [ k { ƒ Scan the option code – 2 listed on the fold out back cover. C FF FS , < L \ l | ƒ Scan the option code – 4 listed on the fold out back cover. D CR GS - = M ] m } E SO RS . > N ^ n ~ F SI US / ? O _ o DEL ƒ Scan the system command – PROGRAM listed on page 3-11 to enter programming mode. ƒ Scan family code – PREAMBLE to select this family. ƒ Scan the system command – FIN (Finish) to terminate Preamble setting. ƒ Scan the system command – End to exit the programming mode for normal operation.  Example : ASCII “A” → HEX “41”; ASCII “a” → “61” : High Byte of HEX Value : Low Byte of HEX Value A-8 Appendix Bar Code Command Menu Option Code : “0 – 9”, “A – F” 4 0 System Command C 8 5 1 D 9 FIN (Finish) END (Exit) (System List) 6 2 E A SYSLIST (Master Default) 7 3 F B A-9 M_DEFAULT Appendix Bar Code System Command Bar Code System Command Set PC/AT, PS/2 Keyboard Wedge Quick Set Command System Information List (SYSLIST) USB Keyboard Interface Quick Set Command Keyboard Replacement Quick Set Command Factory Default Setting (M_DEFAULT) OmniKey/VersaNet Interface Quick Set Command RS-232 Serial Interface Quick Set Command FuzzyScan PowerTool Host Link Command A-10