1257028-GB_v1.1
CONT-R20
GENERAL DESCRIPTION Control panel for two 24 Vdc motors on swing doors for residential and community use. Basic features: self-programming, stoppage by consumption, receiver incorporated (30 codes), encoder inlet (sensor hall, ...), slow-speed (selectable), connection to portable programmer. This control panel can only work with encoder, it does not allow operating by time.
TECHNICAL CHARACTERISTICS Panel supply Transformer Receiver Optional cards Security device output Courtesy Light contact*
0-12-24Vac 0-12-24Vdc / 150VA (shared power for two motors) 868,35MHz incorporated 30 codes, 2 channels Pluggable receiver card (433,92 / 868,35 MHz) 24V ac / 1A Voltage free (max 100W) impulsionel or manoeuvre time + 30 seconds (selectable with portable programmer) Flash light contact* Voltage free (max 100W) Operating temperature -20ºC to +85ºC Watertightness IP54 Equipment category Class II Base plate size 190x107x36mm Box dimensions 225x195x85 mm * Connect both outputs to 24Vac/dc or both to 230Vac
BASE PLATE DESCRIPTION
1
2
3 4
5 6 7
8 9 10 11 12 13
14 15 16 17 18 19 20 21 22 23 24 25
CONNECTION 1 2 3 4 5 6 7 8
Primary 230V ac Transformer + 230Vac power supply (L) Primary 230V ac Transformer + 230Vac power supply (N) Battery power supply 12Vdc Battery power supply 12Vdc Secondary 0V ac Transformer Secondary 12V ac Transformer Secondary 24V ac Transformer 24Vac./ 1A output
1
26 27 28 29
1257028-GB_v1.1
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
24Vac / 1A output 24V dc motor 1 output 24V dc motor 1 output 24V dc motor 2 output 24V dc motor 2 output Electrolock output Electrolock output Encoder (+) Encoder (H1) Encoder (-) Encoder (H2) Common buttons Stop (NC) (STOP) Start (NO) (START) Common securities Close security contact (NC) (SEC.CL) Open security contact (NC) (SEC.OP)
26 27 28 29
Flash light output contact Flash light output contact Courtesy Light output contact Courtesy Light output contact
CONT-R20
INSTALLATION Any handling of the panel for installation must be carried out with the power supply disconnected. FITTING THE CASING (only box version) · Parts: front casing and container box. · Unscrew the securing points. Insert the cables through the lower holes.
IMPORTANT CONSIDERATIONS FOR START-UP Any optional cards must be connected to the panel with the power supply disconnected. The options and inputs selection also must be done with the power supply disconnected.
OPERATING
Start (START): Contact normally open to open, stop and close. The first press opens, the second press stops (until the limit switch) and the third closes. If it is pressed while the door is closing, it will stop and invert the operation. Stop (STOP): Contact normally closed. This stops the operation. Where not used, turn option 1 on the input switch to ON. Security contacts (SEC.CL/SEC.OP): Contacts normally closed, photocell or magnetic detector type. This acts on opening and closing, causing stoppage and inversion. If the open security contact is activated it does not allow the opening manoeuvre. If the close security contact is
2
1257028-GB_v1.1
CONT-R20
activated it does not allow the closing manoeuvre. Where not used, turn options 2 and 3 on the input switch to ON. 24Vac outlet: enables any unit to be powered at a voltage of 24Vac with a maximum consumption of 1A. Electro-lock (ELECT.LOCK): 12Vdc output to activate an electric latch of a maximum of 2A. Flash light contact (FLASH): Voltage-free maintained contact to activate a Flash light (max 100W) Garage light contact (COURTESY LIGHT): free voltage contact impulsion or manoeuvre time + 30 seconds (selectable with portable programmer) for garage light activation (max. 100W). Encoder inlet (+, H1, -, H2): Allows for an NPN-type encoder (or sensor hall) to be connected at 5Vdc, necessary for the operation by pulses. Battery 12Vdc: allows the connection of a 12Vdc battery. If the power supply is disconnected, the control panel will still operate at low speed during 48 hours approximately or until the battery runs out. Moreover, the control panel incorporates a function that in case of having a battery connected; it checks the level of charge. Reference search function: The control panel knows in each moment in which position it is. If the panel loses power halfway through the operation, on receiving power it goes into reference search mode, in such a way that the door will move until a mechanical stop or the end of the run is reached. Reference search is indicated by the corresponding flashing of the SAFETY light (see table). (Control panel referenced means door totally opened or totally closed). The Aut ref Search parameter (configurable by means of programmer) is selected if the user requires this automatic search or wishes to wait for the START button to be pressed for the reference search. Each door searches its reference independently.
OPTION SWITCH Option No. 1 (AUTO PROG) 2 (AUTO CLOSE.) 3- (NON STOP ON OPENING) 4 (SLOW) 5 (1 MOTOR) 6 (REVERSE STRIKER)
Upper position – ON Self-programming Automatic closure Does not allow for radio reverse on opening
Lower position - OFF Manual programming (default option) Does not close automatically (default option) Allows for radio reverse on opening (default option) Allows for slow speed (default option) Does not allow for slow speed Only Motor 1 operating Two motors operating Opening with reverse striker (1,5s of reverse + 1,5s of activation of electro-lock during the 1,5s of activation of electro-lock during the movement of the door). Only with door totally movement of the door). Only with door totally closed. closed.
INPUT SWITCH Option No. 1 (STOP) 2 (SEC.CL.) 3 (SEC.OP.)
Upper position – ON (default option) Stop button not connected Security Close contact not connected Security Open contact not connected
Lower position - OFF Stop button connected Security Close contact connected Security Open contact connected
OPTION SWITCH BRIDGING JP1 JP2
Pedestrian channel disconnection of the pluggable receiver card (where a single-channel RACK+DCS is used, this bridge must be cut) Integrated radio disconnection (where a pluggable receiver card is used, the cut bridge provides greater range)
3
1257028-GB_v1.1
CONT-R20
LIGHT INDICATORS Function POWER SAFETY ERROR TIMER PROG RADIO PROG
Indicates Power Operating alert (see table TROUBLESHOOTING) Operating fault (see table TROUBLESHOOTING) Operation programming mode Radio programming mode
Default status Normally on Normally off Normally off Normally off Normally flashing
BUTTONS Button START TIMER PROG RADIO PROG
Colour Black Blue Red
Function Start Start pulse or time programming Start transmitter programming
TIMES Controlling Motor operating Wait for automatic close
Minimum --3s
Maximum 32000 pulses 10min
PROGRAMMING
· If stoppage is required during programming, the control panel exits programming automatically for safety reasons. · Before starting any type of operation programming, the corresponding options must be correctly selected (option switch, input switch and option switch bridging) and the safety elements must be connected, where applicable. · Operations can be programmed indifferently using the START button or through a previously programmed transmitter. · If in programming mode for 30 seconds without programming, the equipment will exit programming mode and the TIMER PROG led will switch off.
INSTALLATION EXAMPLE
4
1257028-GB_v1.1
CONT-R20
AUTOPROGRAMMING (option 1 at ON) Programming two motors (option 5 at OFF)
MANUAL PROGRAMMING (option 1 at OFF) Programming two motors (option 5 at OFF)
AUTOPROGRAMMING
MANUAL PROGRAMMING
DOOR MOVEMENT
STEP
DOOR MOVEMENT
STEP
ON ON
ON
1s
1s START
START SLOW
1
FAST
SLOW
1
M2
FAST
M2
M1
M1
SLOW
2
FAST
2 M2
M1 SLOW
FAST
SLOW
3
AUTO
3
M2
2s
FAST
M2
M1
M1
SLOW
4
FAST
4 M2
M1 SLOW
5
FAST
AUTO M2
M2
M1
M1 SLOW
FAST
6
6
M2
M1 SLOW
7
AUTO
FAST
SLOW
M2
7
M1
FAST
M2
M1
SLOW
FAST
8
8
2s
M2
M1 SLOW
FAST
SLOW
FAST
M2
M1
9
AUTO M2
M1
END
OFF
10
SLOW
FAST
M2
M1
11 AUTO
5
END
OFF
OFF
1257028-GB_v1.1
CONT-R20
Programming one motor (option 5 at ON) Follow the same steps described above for two motors, but with only one motor. PARTIAL OPENING PROGRAMMING In programming, use the second recorded transmitter channel button to programme partial opening. Then programme as required using the steps described above. PARAMETER CONFIGURATION FROM PROGRAMMER There are different parameters that can be configured by portable programmer. Below is a description of the most basic (level 1). Refer to the programmer instruction manual and the annex CONT-R20 configurable parameters, for further information. -
BackJump Open: Indicates / Selects the back jump function for the opening operation. BackJump Close: Indicates / Selects the back jump function for the closing operation. Battery available: Enables the operation with battery in case of failure of the power supply. Autoclosing time: Indicates / selects the seconds of automatic standby time. Max. No. security reversals: Indicates / selects the number of security trigger reversals permitted before auto-close is inhibited. Last 4cm inh. space: Indicates / selects the distance equivalent to the last 4cm of travel of the door. Note: This parameter must be verified for the compliance with the standard. Sensitivity level 1: Indicates the basic level of sensitivity with which an obstacle due to overcurrent will be detected during normal operations. Operation counter: Indicates the number of operations made to date. Oper. counter limit: Indicates / selects the limit number of operations for the panel. Equip.: Shows an equipment identifier. Closing by Sec.contact: Indicates / selects whether the panel allows the closing by security contact. Gar. Light pulsed: Indicates / selects whether the garage Light contact is impulsion (2s) or manoeuvre time + 30 seconds.
TROUBLESHOOTING
The following table indicates the possible causes of operating failures in the control panel through the ERROR and SAFETY leds.
Description Stop enabled Open security contact enabled Close security contact enabled Panel not referenced or waiting to start reference search Panel programmed without references End of run or programmed reference not reached Maximum current limit exceeded M1 Maximum current limit exceeded M2 No encoder pulses M1 No encoder pulses M2 Internal error Excess consumption on opening M1 Excess consumption on opening M2 Excess consumption on closure M1 Excess consumption on closure M2 The control panel operates with battery
SAFETY led ON 1 flashes 2 flashes OFF OFF OFF OFF OFF OFF OFF OFF 1 flash 2 flashes 3 flashes 4 flashes 7 flashes
6
ERROR led ON 1 flashes 2 flashes 7 flashes 8 flashes 9 flashes 10 flashes 11 flashes 12 flashes 13 flashes 14 flashes OFF OFF OFF OFF OFF
1257028-GB_v1.1
CONT-R20
RECEIVER OPERATIONS Upon receiving a code, the equipment checks whether it is in its memory, activating the corresponding relay. Channel operating Channel 1 Channel 2
Alternative function Pedestrian function
Manual programming 1) Normal programming Press the RADIO PROG programming button for 1 sec. The programming RADIO PROG pilot light will come on and the equipment will emit an acoustic signal. The equipment will enter normal programming. Send the code and the channel to be programmed by pressing the transmitter. By pressing the transmitter channel, opening and closure is activated in automatic operating mode. 2) Programming for pedestrian function In normal programming, press the RADIO PROG programming button again and keep it pressed down until the RADIO PROG pilot light flashes and the equipment emits a short acoustic signal. The equipment will now have entered programming for pedestrian function. Press the required channel of the transmitter to be programmed. Every time a transmitter is programmed, the equipment will issue an acoustic signal for 0.5 sec. After 10 seconds without programming or by pressing the programming button, the equipment will exit programming mode, issuing two 1 sec. acoustic signals. If, on programming a transmitter, the equipment memory is full, it will issue seven 0.5 sec. acoustic signals and exit programming. N.B.: Each transmitter channel can be configured independently on the equipment, occupying only one memory position. Programming by radio To enter programming, press the first two buttons on a transmitter that has already been registered on the equipment. The equipment will issue a 1 sec. acoustic signal. On pressing any button on the new transmitter, the equipment will issue another 1 sec. acoustic signal to indicate that it has been memorised. The new transmitter will maintain the same channel configuration as the transmitter registered. After 10 seconds without programming or by quickly pressing the programming button or pressing the first two transmitter buttons, the equipment will exit programming mode, issuing two 1 sec. acoustic signals.
CODE CANCELLATION (TOTAL RESET) In programming mode, the programming button is held down and the “MR” reset jumper is bridged for 3 secs. The equipment will issue 10 short acoustic warning signals followed by others at a faster pace to indicate that the operation has been successful. The equipment is now in programming mode. The pilot programming light will also follow the acoustic indications by flashing. After 10 seconds without programming or quickly pressing the programming button, the equipment will exit programming mode, issuing two 1 sec. acoustic signals.
OPTIONAL CARDS RECEIVER CARD 433MHz / 868MHz This acts on the panel with transmitters, proximity keys or smart cards in the same way as the start button.
7
1257028-GB_v1.1
CONT-R20
EQUIPMENT USE Designed for the automation of garage doors as per the general description. Not guaranteed for other uses. The manufacturer reserves the right to modify equipment specifications without prior notice.
IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION Disconnect the power supply whenever you proceed to the installation or repair of the control panel. · The panel must be installed while the power is disconnected. · Before installing the panel, remove all unnecessary ropes or chains and disable any equipment such as locks that is not necessary for the automatic operation. · Before installing the panel, check that the door is in good mechanical condition, correctly balanced and that it opens and closes correctly. · Install the manual unlocking device at a height lower than 1.8m. · Install any permanent control next to the door away from any moving part and at a minimum height of 1.5m. · An easily accessible disconnection device must be fitted to the wiring for permanently connected equipment. It is wise for this to be an emergency switch. · Following installation, check that the mechanism is correctly adjusted and that the automatism inverts when the door enters into contact with a 50mm wider object located at the closing edge of the door. · This equipment can only be handled by a specialist fitter, by maintenance staff or by a suitably trained operator. · To connect the power supply and motor wiring, 2.5 mm2 section terminals must be used. · Use protective goggles when handling the equipment. · Fuses must only be handled when the appliance is disconnected from the mains. The 24 Vac outlet is protected by a resettable fuse. In the event of this outlet short-circuiting, disconnect the power for 2 minutes to ensure the fuse resets. · The instructions for using this equipment must remain in the possession of the user. · European door normative EN 12453 and EN 12445 specify the following minimum protection and door safety levels: - for single-family homes, prevent the door being able to come into contact with any object or limit the contact force (e.g. stoppage by consumption or security edge) and, in the event of automatic closure, a presence detector (e.g. photocell) must be added. - for commercial and community installations, prevent the door being able to come into contact with any object or limit the contact force (e.g. stoppage by consumption or security edge) and a presence detector (e.g. photocell) must be added. · This panel incorporates a current measuring system that can be used for the safety of the installation (replacing the band). Whether this safety system fulfils door regulations depends largely on the door, which makes it necessary to carry out onsite measurements in each installation in order to adjust forces.
IMPORTANT SAFETY INSTRUCTIONS FOR USE · Do not allow children to play with the door controls. · Keep the remote controls out of the reach of children. · Watch the door movement and keep people away until the door is fully open or closed. · Precaution when operating the manual unlocking device, as the door may suddenly fall due to the bad condition of the springs or door unbalance. Details on how to use the manual unlocking device must be provided by the manufacturer or the device installer.
8
1257028-GB_v1.1
CONT-R20
· Examine the installation frequently, especially the cables, springs and supports, to detect signs of wear, damage or unbalance. Do not use the door if repair work or adjustments are required, as this may cause damage. · Check once a month whether the automatism inverts when the door enters into contact with a 50mm wider object located at the closing edge of the door. Readjust if necessary.
JCM TECHNOLOGIES, S.A. declares herewith that the product CONT-R20 complies with the relevant fundamental requirements as per Article 3 of the R&TTE Directive 1999/5/EG, insofar as the product is used correctly.
CE DECLARATION OF CONFORMITY See website: www.jcm-tech.com
9