Preview only show first 10 pages with watermark. For full document please download

Contractor And Ftx Spray Guns Instructions-parts, English

   EMBED


Share

Transcript

Instructions-Parts Contractor & FTx Spray Guns Contractor Models: 288420, 288421, 288425, 288475, 288477, 288478, 826085, 288009, 262114 FTx Models: 288427, 288428, 288429, 288430, 288431, 288436, 288438, 288477, 288478, 826086, 288008, 262116, 17C926 311861J EN For the application of architectural paints and coatings. Maximum Working Pressure: 3600 psi (248 bar, 24.8 MPa) IMPORTANT SAFETY INSTRUCTIONS. Read all warnings and instructions in this manual. Refer to your sprayer instruction manual for Pressure Relief, priming and spray instructions. Save all instructions. ti8501b ti8522b The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable. WARNING SKIN INJECTION HAZARD High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment. • Do not point gun at anyone or at any part of the body. • Do not put your hand over the spray tip. • Do not stop or deflect leaks with your hand, body, glove, or rag. • Do not spray without tip guard and trigger guard installed. • Engage trigger lock when not spraying. • Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment. FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: • Use equipment only in well ventilated area. • Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc). • Keep work area free of debris, including solvent, rags and gasoline. • Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present. • Ground all equipment in the work area. See Grounding instructions. • Use only grounded hoses. • Hold gun firmly to side of grounded pail when triggering into pail. • If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem. • Keep a working fire extinguisher in the work area. PRESSURIZED ALUMINUM PARTS HAZARD Use of fluids that are incompatible with aluminum in pressurized equipment can cause a serious chemical reation and equipment rupture. Failure to follow this warning may result in death, serious injury, or property damage. • Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents. • Many other fluids may contain materials that are incompatible with aluminum. Contact your material supplier for verification. II 2 G WARNING EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. • Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS forms from distributor or retailer. • Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only. • Do not alter or modify equipment. • Use equipment only for its intended purpose. Call your distributor for information. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. • Do not kink or over bend hoses or use hoses to pull equipment. • Keep children and animals away from work area. • Comply with all applicable safety regulations. PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or in the operating area of the equipment to help protect you from serious injury. This equipment includes but is not limited to: • Protective eyewear, gloves, hearing protection • Clothing and respirator as recommended by the fluid and solvent manufacturer Pressure Relief Procedure Setup Make sure sprayer is turned off and unplugged from power source. Refer to your sprayer manual for priming and spray instructions. Follow this Pressure Relief Procedure whenever instructed to relieve pressure, stop spraying, check or service equipment, or install or clean spray tip. 1. 2. Turn OFF power and turn sprayer pressure control to lowest pressure setting. Hold gun against side of flushing pail. Trigger gun into pail to relieve pressure. If you suspect spray tip or hose is clogged or that pressure has not been fully relieved after following the steps above, VERY SLOWLY loosen tip guard retaining nut or hose end coupling to relieve pressure gradually, then loosen completely. Clear hose or tip obstruction. Gun Trigger Lock (2) To prevent injury when the gun is not in use, always set the gun’s trigger lock (2) if unit is being shut down or left unattended. Trigger Locked (no spray) Trigger Unlocked (spray) Connect Gun to Sprayer 1. 2. 3. Attach supply hose to sprayer fluid outlet. Attach other end of supply hose to gun swivel (8). Use two wrenches (one on the swivel (8) and one on the hose), to tighten all connections securely. Refer to sprayer instruction manual for priming instructions. Installing Tip (26) and Guard (25) on Gun 1. 2. 3. 4. If equipment has recently been operated, relieve pressure. Set trigger lock (2). Using a pencil or similar object, insert seal (24) into back of guard (25). Install guard (25) over end of gun (1). Insert tip (26) in guard (25). Tighten retaining nut. Operation Spraying ti10166a ti10167a 1. 2. 3. 4. 2 Unlock trigger lock (2). Be sure the arrow shaped tip (26) faces forward (spray). Hold gun perpendicular and approximately 12-inches (304 mm) from surface. Move gun first, then pull gun trigger (13) to spray a test pattern. Slowly increase pump pressure until coverage is uniform and even (see sprayer instruction manual for additional information). 311861J Aligning Spray Clearing Clogs Relieve pressure. Set trigger lock (2). Loosen guard retaining nut. Loosen guard retaining nut. Align guard (25) horizontally to spray a horizontal pattern. Align guard (25) vertically to spray a vertical pattern. 1. 2. 3. 4. (3) Horizontal (4) Vertical 1. 2. 3. Parts Relieve pressure. Set trigger lock (2). Rotate tip (26) 180°. Unlock trigger lock (2). Trigger gun into pail or onto ground to remove clog. Set trigger lock (2). Rotate tip (26) 180° back to spray position. Cleanup Flush gun after each work shift and store in a dry location. Do not leave the gun or any parts in water or cleaning solvents. ti9535B ti9534B Parts 14 1 20 Ref. 1 22 21 5 15a 15b 16/17 (see page 4) 6 5 2 13 11 7b 19 12 6 7 7a 7b 8 9 10 11 12 13 7a 15K282 15J735 15J736 288811 120733 15J706 15J698 120834 15J409 15J768 15J769 9 31 Part 288812 289914 287032 287033 287034 120777 10 ti8502b 8 14 15 15a 15b 16 17 19 20 21 22 31 117602 288488 15J696 105334 15J464 15J528 121093 15B549 119799 Description Qty HOUSING, assy., Contractor 1 HOUSING, assy., FTX 1 FILTER, 60 mesh 1 FILTER, 100 mesh 1 FILTER, 60 and 100 mesh combo 1 PACKING, o-ring 1 HANDLE 1 Contractor Gun 1 FTX Gun 1 FTX-A Gun (not shown) 1 SWIVEL, assy, gun 1 O-RING, urethane, clear 1 RETAINER, guard, trigger 1 TUBE, handle, Contractor Gun 1 SCREW, set, Contractor Gun 1 TRIGGER, Contractor/FTX Gun, 2-fin- 1 ger TRIGGER, Contractor Gun, 4-finger 1 (not shown) TRIGGER, FTX Gun, 4-finger (not 1 shown) SCREW, shoulder, pan hd 2 KIT, needle, repair 1 NEEDLE, assembly 1 DIFFUSER, assembly 1 PIN, trigger (page 4) 1 NUT, lock, hex (page 4) 1 GUARD, trigger 1 GUIDE, spring 1 SPRING, compression 1 NUT, end 1 BRUSH, cleaning 1 Tip and Guard RAC X 24 24 RAC 5 Ref. 24 25 26 25 311861J 26 ti8505a 25 26 _ Part 246453 243281 246215 243161 LTX515 LTX517 286515 286517 PAA517 PAA515 262517 Description Qty 1 OneSeal , RAC X (5-pack) ™ 1 OneSeal , RAC 5 (5-pack) GUARD, RAC X 1 GUARD, RAC 5 1 TIP, spray 515, RAC X 1 TIP, spray 517, RAC X 1 TIP, spray 515, RAC 5 1 TIP, 517, RAC 5 1 TIP, spray, latex, RAC X (517), Europe 1 TIP, spray, latex, RAC X (515), Europe 1 TIP, spray. 517, RAC 5, Europe 1 ™ 3 Maintenance Failure to clean or replace the filter or damaged handle bore can result in serious injury. Before performing any maintenance on gun, read all warnings on front cover of this manual and relieve pressure. Cleaning/Replacing Filter (5) A plugged filter reduces gun performance. Clean filter after each use. Relieve pressure. Set trigger lock (2). Disconnect fluid hose from gun at swivel (8). Disconnect trigger guard (19) from guard retainer (10). Unscrew handle (7) from gun (1). Remove filter (5) through top of handle (7). Inspect filter (5) for damage to the filter mesh. Replace the filter if the filter mesh has holes or voids. 7. Clean filter (5). Use a soft brush to loosen and remove excess debris. 8. Inspect handle bore (7) for damage. Replace the handle bore if it is corroded or pitted and check material for compatibility with aluminum. 9. Insert clean filter (5) into handle (7). 10. Reattach handle (7) to gun (1). Tighten securely. 11. Reconnect trigger guard (19) to guard retainer (10). 1. 2. 3. 4. 5. 6. Repair Tools needed: • 8-inch adjustable wrench • 1/4-inch nut driver Replacing Needle 15a 17 15b Relieve pressure. Set trigger lock (2). Remove tip (26) and guard (25) from gun (1). Disconnect fluid hose from gun at swivel (8). Remove nut (17) and trigger pin (16). Unscrew diffuser (15a) from front of gun (1). Remove needle assembly (15b) through front of gun (1). Use a soft brush to clean out internal passages of gun. Grease o-rings of new needle using a non-silicon grease. Guide new needle (15b) through front of gun (1) making sure the flat sides (a) of the needle assembly face the sides of gun housing. 10. Install diffuser (15a). Torque diffuser to 26-30 ft-lbs (35.25 - 43.38 N•m). 11. Replace pin (16) and nut (17). 1. 2. 3. 4. 5. 6. 7. 8. 9. Translated Manuals Spanish - 312098 Estonian - 312277 French - 312099 Latvian - 312278 Dutch - 312265 Lithuanian - 312279 German - 312266 Polish - 312280 Italian - 312267 Hungarian - 312281 Turkish - 312268 Czech - 312282 Greek - 312269 Slovakian - 312283 Croatian - 312270 Slovenian - 312284 Portuguese - 312271 Romanian - 312285 Danish - 312272 Bulgarian - 312286 Finnish - 312273 Chinese - 312287 Swedish - 312274 Japanese - 312288 Norwegian - 312275 Korean - 312289 Russian - 312276 16 1 a Translated manuals can be requested through a distributor or at www.graco.com. ti8510b Technical Data Maximum working pressure 3600 psi (248 bar, 24.8 MPa) Fluid orifice size 0.125 in. (3.18 mm) Weight (with tip and guard) 22 oz. (630 g) Inlet 1/4 npsm swivel Maximum material temperature 120°F (49°C) Wetted parts Stainless steel, polyurethane, nylon, aluminum, tungsten carbide, solvent resistant elastomer, brass Noise Level* Sound power 87 dBa Sound pressure 78 dBa *Measured at 3.1 feet (1m) while spraying water-based paint, specific gravity 1.36, through a 517 tip at 3000 psi (207 bar, 20.7 MPa) per ISO 3744 For complete warranty information contact your Graco distributor, call Graco customer service: 1-800-690-2894 or visit our website: www.graco.com All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. For patent information, see www.graco.com/patents. Original instructions. This manual contains English. MM 311861 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA Copyright 2007, Graco Inc. All Graco manufacturing locations are registered to ISO 9001. www.graco.com Revised November 2014