CONVENTIONAL OPTICAL DETECTOR The Haes conventional optical smoke detector has a moulded self-extinguishing white polycarbonate case with wind resistant smoke inlets. The sensing chamber is a black moulding configured as a labyrinth which prevents penetration of ambient light. The labyrinth has a fine gauze insect-resistant cover. • • •
Responds well to slow-burning, smouldering fires Well suited for bedrooms and escape routes Unaffected by wind or atmospheric pressure
TECHNICAL DATA Optical Smoke Detector Part No 55000-317HSL Base Part No 45681-200HSL
Number of Consecutive Sensed Alarm Signals Needed To Trigger Detector Alarm: 3
Specifications are typical and given at 23°C and 50% relative humidity unless otherwise stated.
Supply Wiring: Two wire monitored supply, polarity insensitive
Detector Type: Point type smoke detector for fire detection and fire alarm systems for buildings
Terminal Functions:
Detection Principles: Photo-electric detection of light scattered in a forward direction by smoke particles Chamber Configuration: Horizontal optical bench housing an infrared emitter and sensor arranged radially to detect scattered light
L1 IN & L2 L1 OUT & L2 -R
supply in connections (polarity insensitive) supply out connections (polarity insensitive) remote indicator negative connection
Supply Voltage: 9 to 33 Volts dc
Sensor: Silicon PIN photo-diode
Ripple Voltage: 2v peak to peak maximum at 0.1Hz to 100kHz
Emitter: GaAs Infra-red light emitting diode
Quiescent Current: 30-50μA at 24v
Sampling Frequency: Once every 3 seconds
Switch-on Surge Current: 115μA at 24v
Confirmation Frequency: Once every 2 seconds
Alarm Voltage: 6 to 28v
Normal Alarm Current: 61mA at 28v 52mA at 24v 18mA at 10v Alarm Indicator: Clear light emitting diode (LED) emitting red light
Sensitivity: Nominal alarm threshold of 0.15dB/m obscuration, measured in accordance with EN54-7:2000 Temperature Range: -20°C to +60°C (no condensation or icing)
Design Alarm Load: 420Ω in series with a 2v drop
Humidity: 0% to 95% relative humidity (No condensation)
Holding Voltage: 6v (min)
Wind Speed: Insensitive to wind
Holding Current: 10mA (min)
Atmospheric Pressure: Insensitive to atmospheric pressure
Minimum Voltage Reuired To Illuminate Indicator: 12v
IP Rating: 23D in accordance with BS EN 60529
Alarm Reset Voltage: 1v
Dimensions: (diameter x height) Detector: 100mm x 42mm Detector in Base:100mm x 50mm
Alarm Reset Time: 1 second Remote Output Characteristics: Remote is a current sink to the negative line limited to 17mA
Weights: Detector: 99g Detector in Base: 150g Materials: Detector Housing: White polycarbonate V-0 rated to UL 94 Terminals: Nickel plated stainless steel
CONVENTIONAL IONISATION DETECTOR The Haes conventional ionisation smoke detector has a moulded self-extinguishing white polycarbonate case with wind resistant smoke inlets. Inside the detector case a printed circuit board has the ionisation chamber mounted on one side and the signal processing electronics on the other. The outer smoke chamber has inlet apertures fitted with insect resistant mesh. • • • TECHNICAL DATA Ionisation Smoke Detector Part No 55000-217HSL Base Part No 45681-200HSL Specifications are typical and given at 23°C and 50% relative humidity unless otherwise stated. Detector Type: Point type smoke detector for fire detection and fire alarm systems for buildings
L1 OUT & L2 -R
supply out connections (polarity insensitive) remote indicator negative connection
Supply Voltage: 9 to 33 Volts dc Ripple Voltage: 2v peak to peak maximum at 0.1Hz to 100kHz
Detection Principles: Ionisation chember
Quiescent Current: 20-45μA at 24v
Chamber Configuration: Twin compensating chambers using one single-sided ionising radiation source
Switch-on Surge Current: 110μA at 24v
Radioactive Isotope: Americium 241 Activity: 33.3 k Bq, 0.9 µCi Supply Wiring: Two wire monitored supply, polarity insensitive Terminal Functions: L1 IN & L2
supply in connections (polarity insensitive)
Alarm Voltage: 6 to 33v Normal Alarm Current: 61mA at 28v 52mA at 24v 18mA at 10v Alarm Indicator: Red light emitting diode (LED) Design Alarm Load: 420Ω in series with a 2v drop
Responds well to fast-burning, flaming fires Designed to operate in a variety of environments Minimal effects from temperature, humidity or atmospheric pressure
Holding Voltage: 6v (min) Holding Current: 10mA (min) Minimum Voltage Reuired To Illuminate Indicator: 12v Alarm Reset Voltage: 1v Alarm Reset Time: 1 second Remote Output Characteristics: Remote is a current sink to the negative line limited to 17mA
Humidity: 0% to 95% relative humidity (No condensation) Wind Speed: 10m/s maximum Atmospheric Pressure: Automatic compensation by dual chambers to maintain sensitivity up to a height of 2000m IP Rating: 23D in accordance with BS EN 60529 Dimensions: (diameter x height) Detector: 100mm x 42mm Detector in Base:100mm x 50mm
Sensitivity: Nominal threshold Y value of 0.7 to EN54-7:2000
Weights: Detector: 102g Detector in Base: 153g
Temperature Range: -20°C to +60°C (no condensation or icing) Storage: -30oC to +80oC
Materials: Detector Housing: White polycarbonate V-0 rated to UL 94 Terminals: Nickel plated stainless steel
Temperature Compensation: Automatic compensation by dual chambers to comply with EN54-7:2000 across the operating temperature range
www.haes-systems.com • +44 (0) 1895 422066
Conventional Systems co nventional detec tors
CONVENTIONAL HEAT DETECTOR The Haes conventional heat detector has a low air-flow resistance case which allows good contact between the sensing thermistor and the surrounding air. The device monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. There are 4 heat detectors in the range, A1R, BR, CR & CS designed to suit a wide variety of operating conditions. •
Ideal in environments that are dirty or smoky under normal conditions such as loading bays and car parks Unaffected by wind or atmospheric pressure
•
TECHNICAL DATA Heat Detector Part No 55000-122HSL, 55000-127HSL, 55000-132HSL, 55000-137HSL
Ripple Voltage: 2v peak to peak maximum at 0.1Hz to 100kHz
Holding Current: 10mA
Base Part No 45681-200HSL
Quiescent Current: 24v = 45µA 9v = 40µA
Minimum Voltage Reuired To Illuminate Indicator: 12v
Specifications are typical and given at 23°C and 50% relative humidity unless otherwise stated. Detector Type: Point type heat detector for fire detection and fire alarm systems for buildings Supply Wiring: Two wire monitored supply, polarity insensitive Terminal Functions: L1 IN & L2 L1 OUT & L2 -R
supply in connections (polarity insensitive) supply out connections (polarity insensitive) remote indicator negative connection
Supply Voltage: 9 to 33 Volts dc
Weights: Detector: 80g Detector in Base: 131g Materials: Detector Housing: White polycarbonate V-0 rated to UL 94 Terminals: Nickel plated stainless steel
Remote Output Characteristics: Remote is a current sink to the negative line limited to 17mA
Switch-on Surge Current: As per quiescent current Alarm Voltage: 6 to 28v
Temperature Range: -20°C to +90°C (no icing) Storage: -30oC to +120oC
Alarm Current: 24v = 52mA 9v = 17mA
Class
Max application temperature o C
Max static response temperature o C
A1R
50
65
55000-122HAE
BR
65
85
55000-127HAE
CR
80
100
55000-132HAE
CS
80
100
55000-137HAE
Humidity: 0% to 95% relative humidity
Alarm Indicator: Red light emitting diode (LED)
Atmospheric Pressure: Unaffected
Design Alarm Load: 420Ω in series with a 2v drop
IP Rating: 23D in accordance with BS EN 60529
Holding Voltage: 6v
Dimensions: (diameter x height) Detector: 100mm x 42mm Detector in Base:100mm x 50mm
Part Number
MOUNTING BASE The Haes conventional mounting base has been designed to enable detectors to be fitted without the need of force particularly useful when fitting to suspended ceilings. The base has a one way only fit and detectors can be locked into place by a grub screw using a 1.5mm hexagonal screw driver. • • • •
Detector locking mechanism One way fit Easy to wire Contains an earth connector
TECHNICAL DATA Mounting base Part No. 45681-200HSL
Remote LED
+
L1 IN
From control panel
L1OU T EARTH L2
—R
L1 IN
—R
L1OU T EARTH L2
L1 IN
L1OUT
—R
End-of-line devic e
EARTH L2
– Schematic wiring diagram - Haes mounting base