Preview only show first 10 pages with watermark. For full document please download

Conyers Lab Tested By ____brian C

   EMBED


Share

Transcript

Conyers Lab One Lithonia Way Building 3 Conyers, GA 30012 Report Number LTL20533S Test Date 8/21/11 Model Number 2TL4 46L RW A19 D50 LP835 PHOTOMETRIC........... THERMAL..................... ENVIRONMENT......…. STRUCTURAL.............. ELECTRICAL............... OTHER........................... TEST DESCRIPTION Sphere testing on 2TL4 46L RW A19 D50 LP835. 2TLED 2X4 with A19 lens. REQUESTED BY B. HARRIS REQUEST NUMBER F11261 TEST PROCEDURE IES LM-79 EQUIPMENT The Measuring and Test Equipment used for tests have the minimum required accuracy and range/functions, and were calibrated to assure these levels. Serial # Type Cal. Date Cal .Due Meter # Make Model # 41 Voltech PM100 5226 Power Analyzer 2011/05/04 2012/05/03 44 Fluke 2100A 535031 Digital Thermometer 2011/05/03 2012/05/02 151 LABSPHERE LPS-200-H 6906 POWER SUPPLY 2011/05/05 2012/05/04 162 LABSPHERE Mc9801:2480 98010115 Spectrometer 2011/07/28 2012/07/28 Lithonia ID LPS-12 Make Chroma ATE Description AC Supply Model # 6415 Serial # 64150136 Output Voltage 0-300AC Output Power 1500VA DATA Sample Volts 120.3 Input Electrical Data Amps Watts .422 49.9 Temperature Sample @ Test Point Ambient 31.6 C 25 C Stabilization Time 1 HOUR See following pages for Spectral Result details. RESULTS Sample Luminous Flux (Lumens) Input Power (Watts) Luminous Efficacy (Lumens/Watt) CCT 4687 49.9 93.9 3619 Tested by ____Brian C. Buggs________________________________________________(Printed and Signature each page) Reviewed by ___Jim Hospodarsky___Fred Carpenter /_____________________________________________(Signature) Print Date 2011-08-21 Report Page 1of 3 Acuity Data Sheet Version 1 Issued 2009/02/02 ADS-UL1598-2008 Revised 2009/02/02 Scale V/A/W ºC V,A Conyers Lab One Lithonia Way Building 3 Conyers, GA 30012 Report Number LTL20533S Test Date 8/21/11 Model Number 2TL4 46L RW A19 D50 LP835 Spectral Results Method lumens 4686.579 Operator Name: Power(Watts): 1.43E+01 Customer Name: 0.3988 CIE x: CIE y: CIE z: u prime: v prime: Duv: Kelvin: Nominal CCTs: Dominant Wavelength: Peak Wavelength: Center Wavelength: Full-Width-Half-Max Wavelength: Centroid Wavelength: Purity: R1: R2: R3: R4: R5: R6: R7: R8: R9: R10: R11: R12: R13: R14: Ra: 0.3876 0.2136 0.2328 0.509 0.000173 3619 3500K 580 Part Number: Serial Number: Time: Date: Comment: CriDC: Integration Time(ms): Start Wavelength: Stop Wavelength: Brian C. Buggs COMMERCIAL FLUORESCENT 2TL4 46L RW A19 D50 LP835 82111 14:22:29 8/21/2011 0.000173 15 350 800 595 546 215 570 36.2 79.4 88.3 95.4 80.6 80 84.4 84.6 61.7 4.8 73.1 79.3 67.3 81.3 97.6 81.8 Tested by ____Brian C. Buggs________________________________________________(Printed and Signature each page) Reviewed by ___Jim Hospodarsky___Fred Carpenter /_____________________________________________(Signature) Print Date 2011-08-21 Report Page 2of 3 Acuity Data Sheet Version 1 Issued 2009/02/02 ADS-UL1598-2008 Revised 2009/02/02 Conyers Lab One Lithonia Way Building 3 Conyers, GA 30012 Test Date 8/21/11 Model Number 2TL4 46L RW A19 D50 LP835 Report Number LTL20533S Spectral Flux Graph Chromaticity Diagram Tested by ____Brian C. Buggs________________________________________________(Printed and Signature each page) Reviewed by ___Jim Hospodarsky___Fred Carpenter /_____________________________________________(Signature) Print Date 2011-08-21 Report Page 3of 3 Acuity Data Sheet Version 1 Issued 2009/02/02 ADS-UL1598-2008 Revised 2009/02/02