Transcript
Standard
Dome
IR Bullet
IR Bullet
Connection
Dome Camera
Connection
Dome Camera 3) Connection to RS-485
1) Connection to Monitor
VIDEO
Using an RS485 connection you can control the OSD menu via the DVR or system controller. (1) Control via a PC Using a RS-485 converter, It connects to RS-485 control cable outside camera and serial cable EX) SERIAL PORT OF THE PC(COM1) → SERIAL CABLE → RS-485 CONVERTER → RS-485 CONTROL CABLE (2) When controlling via a DVR or system controller connect the RS-485. It connects the RS-485 control cable in the connection terminal of 485 control boards which are connected with the DVR or System Controller. - As the connecting method varies with the instruments, refer to the manual supplied with the instrument. - If necessary, you can connect the monitor to the REMOTE jack on the back of your camera. - Only connect the cable when the power is turned off. - Set the 75Ω / Hi-Z selection switch as shown below if you have an intermediate device.
485 Control Board Connection Port
RS-485 Control Port
(+) CONNECTION TERMINAL
Brown (TRX+)
(- ) CONNECTION TERMINAL
Blue (TRX-)
ç RS-485 Communication parameters establishment initial value Protocol : SAMSUNG Baud Rate : 9600bps Address : 1-255
VIDEO
Item
Camera ID
Initial value
1
BAUD RATE UART MODE 9600
8-NONE-1
RET PKT ENABLE
NOTE 2) Connection to Power Connect the adaptor to the power input connector as shown in the figure right. The Standard voltage for camera operation : DC 12V ± 10%, AC 24V±10%.
Note
Power Input
- When using a control system to operate the camera, please use the protocol: SAMSUNG, PELCO-P or PELCO-D . - When use the RS485 control cable isolate the Drain wire.
4) Connection to Alarm
If you wish to use RS-485 connection, verify the proper polarity.
12
Please see above RS485 connection picture. Normal Alarm output signal open, and when motion detection operate, alarm output signal low to GND. 13
Standard Camera
Standard Camera 1) Connection to Monitor
- As the connecting method varies with the instruments, refer to the manual supplied with the instrument. - If necessary, you can connect the monitor to the REMOTE jack on the back of your camera. - Only connect the cable when the power is turned off. - Set the 75Ω / Hi-Z selection switch as shown below if you have an intermediate device.
2) Connection to Power Connect the adaptor to the power input connector as shown in the following figure . The Standard voltage for camera operation : DC 12V ± 10%, AC 24V±10%. Note
DC12V Only
20
21
CCVC Connection
CCVC Connection
1. TO CONTROL THE CAMERA VIA COAXIAL COMMUNICATIONS
3. Setting Please check the menu of your camera, and setting like below and also to match the menu of your camera. For more setting information please check SCX-RD100 manual.
CAMERA BNC jack
1) Connect the VIDEO IN of the unit and VIDEO OUT of the A1 Camera directly. - For proper data communication, the unit and A1 camera should be connected directly. (If you connect a DVR or keyboard in the middle of the main unit and A1 camera, bidirectional communication will not be established.) 2) Connect VIDEO OUT of the main unit to a monitor’s video input terminal. 3) Setting the protocol and address and baud rate, please the next page.
2. TO CONTROL THE CAMERA USING RS-485 DEVICE VIA COAXIAL COMMUNICATIONS
CAMERA BNC jack
1) Connect the VIDEO IN of the unit and VIDEO OUT of the A1 Camera directly. - For proper data communication, the unit and A1 camera should be connected directly. (If you connect a DVR or keyboard in the middle of the main unit and A1 camera, bidirectional communication will not be established.) 2) Connect VIDEO OUT of the main unit to a monitor’s video input terminal. 3) Connect TX(+/-) of RS-485 device to RX(+/-) of the main unit. (For a full duplex system, connect RX(+/-) of RS-485 device to TX (+/-) of main unit additionally.) 4) Setting the protocol and address and baud rate, please the next page. 5) Using RS-485 device, you can control the camera menu.
22
23
Installation
IR Bullet Camera
1) Metal Bracket Fixed - using 4 screws, affix the metal bracket to wall or other surfaces. 2) Power Connect & Monitor Impedance Made sure which power supply that you selected before you use. - DC12V regulated power supply (DC12V only) Dual power supply (AC24V/DC12V) - To avoid fire or shock hazard, must use a UL listed power supply. - Set the monitor impedance switch to 75½. Check the impedance switch when the screen turns blurred. 3) Focus and Functions Adjust - Loose the magnet-screw , and open the osd-cover , and use the extra cable to adjust the focus and others functions . After finished, please tighten the osd-cover and
Connection
IR Bullet Camera 1) Connection to Monitor
VIDEO
Camera
magnet-screw carefully . Note 1. When you tighten the osd-cover, please make sure that you tighten well and already adjust the function that you wish. 2. Before you connect the power , please check anywhere like that screw and cable.
- As the connecting method varies with the instruments, refer to the manual supplied with the instrument. - If necessary, you can connect the monitor to the REMOTE jack on the back of your camera. - Only connect the cable when the power is turned off. - Set the 75Ω / Hi-Z selection switch as shown below if you have an intermediate device.
VIDEO
Camera Series
Camera
2) Connection to Power Connect the adaptor to the power input connector as shown in the figure right. The Standard voltage for camera operation : DC 12V ± 10%, AC 24V±10%.
Note
2.8-12mm TDN Camera
5-50mm TDN Camera
30
If you wish to use RS-485 connection, verify the proper polarity.
31
Power Input