Transcript
COVELINE Series - INSTALLATION and OPERATION INSTRUCTIONS CAUTION: BEFORE CONNECTING THE FIXTURE TO A POWER SUPPLY, MAKE SURE THE POWER IS SWITCHED OFF. corporate t (877) SSL-GREEN f (630) 889-8106 3609 Swenson Ave. St. Charles, IL 60174
DETAILED ILLUSTRATION GENERAL: 1. Before starting the installation, make sure all electricity has been turned off and electrical breaker has been locked out and tagged out. 2. To ensure the success of the installation, be sure to read these instructions and review the diagrams thoroughly before beginning.
FIG-1
3. All electrical connections must be in accordance with local codes, ordinances, or the National Electrical Code. NOTE: The important safeguards and instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur.
INSTALLATION: 1) Remove mounting bracket(s) from fixture. 2) Secure mounting bracket(s) to surface using screws (FIG-1). 3) A ttach fixture to the mounting brackets in the desired position (FIG-1). Grooves on side of fixture clip into mounting bracket and allow you to set desired light direction. Repeat steps 1-3 for mounting multiple fixtures. Fixtures connect end-to-end. (FIG-2)
Terminator Cap Terminator Cap
NOTE: Starter Cable (SC6) and Terminator Cap (TCAP) are required for every run. (Fig-2)
FIG-2
4) Use Extension Cable when necessary, for corners and extending fixture run. (Fig-3)
Starter Cable Starter Cable
IMPORTANT: DO NOT exceed product’s Maximum Run Length. (FIG-4) Use the list below as a reference: • eCoveline (ECVL) - 120 ft • Coveline (CVL) - 60 ft • eCoveline XL (ECVLX) - 80 ft • Coveline XL (CVLX) - 60 ft CAUTION: Before connecting the fixture(s) to power make sure power is off. NOTE: DO NOT connect power until fixtures are properly mounted, connected and wired.
Terminator Cap
FIG-3
Line Voltage Line Voltage
5) F OR DIMMING: Use standard electronic low-voltage trailing edge dimmer (ELV). Product dimmable to 5% full brightness. Refer to specific manufacturer for wiring and operation information. NOTE: For Dimmer, check Watt limitation and current leakage restriction. Starter Cable 6) Once all fixtures are mounted, connected and wired correctly turn power onStarter at the Cable breaker box.
Starter Cable
Line Voltage
Extension Cable (1’, 2’ and 5’Extension lengths) Cable (1’, 2’ and 5’ lengths) Extension Cable (1’, 2’ and 5’ lengths)
Each fixture in the CoveLine Series has a Maximum Run Length. Each fixture in the CoveLine SeriesFIG-4 has a Maximum Run Length. Starter Cable
Each fixture in the CoveLine Series has a Maximum Run Length.
Terminator Cap
Terminator Cap Terminator Cap
7) Then turn the fixtures on. 8) If troubleshooting is necessary, turn power off again at breaker box–lock out and tag out. Rev 1212
CONFIDENTIAL THIS DOCUMENT IS THE PROPRIETARY PROPERTY OF SOLID STATE LUMINAIRES. ANY UNAUTHORIZED TRANSFER, USE OR REPRODUCTION IS STRICLY PROHIBITED. ©2012 SOLID STATE LUMINAIRES.
ADB - Adjustable Bracket for COVELINE Indoor Series - INSTALLATION and OPERATION CAUTION: BEFORE CONNECTING THE FIXTURE TO A POWER SUPPLY, MAKE SURE THE POWER IS SWITCHED OFF. corporate t (877) SSL-GREEN f (630) 889-8106 3609 Swenson Ave. St. Charles, IL 60174
DETAILED ILLUSTRATION GENERAL: 1. Before starting the installation, make sure all electricity has been turned off and electrical breaker has been locked out and tagged out.
Cove Fixture
Mounting Bracket Base
2. To ensure the success of the installation, be sure to read these instructions and review the diagrams thoroughly before beginning.
.174” Holes for attaching bracket
3. All electrical connections must be in accordance with local codes, ordinances, or the National Electrical Code.
Adjustable Bracket
NOTE: The important safeguards and instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur.
9/64 Hex head screw for light angle adjustment
INSTALLATION: 1) The Adjustable Bracket (ADB) for the CoveLine is tightened on the fixture for shipment. IMPORTANT: P rior to fastening the Mounting Bracket to any surface, check the Adjustable Bracket Hex Screw position to allow for optimal degree of rotation. (Fig.1)
Fig. 2 Change Hex Screw position to change degree of rotation Position A: 60° CCW rotation 30° CW rotation
Current Position B: 30° CCW rotation 60° CW rotation
A
B
60°
30°
Fig. 1
NOTE: The Adjustable Bracket allows for 60° rotation in one direction and 30° rotation in the other, depending upon the Hex Screw position. To change the degree of rotation from side to side, move both Hex Screws to the alternate position. (Fig. 2) 2) Fasten Mounting Bracket Base to surface using appropriate screws per local codes. 3) Once the Mounting Bracket is properly secured to the surface, you may need to adjust the light pattern direction. Loosen the two (8/32) Hex Head screws on each side of the bracket using a 9/64 allen wrench. (Fig. 3) 4) A djust the light direction by rotating the fixture angle to your preference. Then retighten the (2) Hex Head Screws to hold the fixture in place. IMPORTANT: D O NOT exceed CoveLine’s Maximum Run Length. Use the list below as a reference: • eCoveline (ECVL) - 120 ft • Coveline (CVL) - 60 ft • eCoveline XL (ECVLX) - 80 ft • Coveline XL (CVLX) - 60 ft
Fig. 3
Check the Hex Screw position.
9/64 Allen wrench
NOTICE The Hex Screw position determines the degree of rotation from side to side. Move the hex screw to the other position to change degree of rotation.
Bracket Base Dimensions 2”
CAUTION: B efore connecting the fixture(s) to power make sure power is off. NOTE: DO NOT connect power until fixtures are properly mounted, connected and wired. Refer to CoveLine Series Installation and Operation instructions.
1”
Loosen both screws to adjust.
2.5” Rev 1114
CONFIDENTIAL THIS DOCUMENT IS THE PROPRIETARY PROPERTY OF SOLID STATE LUMINAIRES. ANY UNAUTHORIZED TRANSFER, USE OR REPRODUCTION IS STRICLY PROHIBITED. ©2014 SOLID STATE LUMINAIRES.