Preview only show first 10 pages with watermark. For full document please download

Cover Mdv - Independent Air Conditioning Solutions

   EMBED


Share

Transcript

Postal Address PO Box 1023 Coorparoo QLD 4151 www.iacs.com.au Brisbane Office 3/49 Miller Street Murarrie QLD 4172 Phone:07 3890 8799 Fax: 07 3890 8799 [email protected] Sydney Office 12/52 Holker Street Silverwater NSW 2128 Phone: 02 9648 0188 Fax: 02 9648 7000 [email protected] Perth Office 3/61 Guthrie Street Osborne Park WA 6017 Phone: 08 9242 8400 Fax: 08 9242 8488 [email protected] Melbourne Office 2/32 De Havilland Road Mordialloc VIC 3195 Phone: 03 9580 7833 Fax: 03 9580 2822 [email protected] ABN: 47 085 475 243 GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 14001 International standard for environmental management. Certificate No.15912E10020R0L COMMERCIAL AIR CONDITIONERS CQ Midea General Refrigeration Equipment Co., Ltd. Is certified under the ISO 14001 International standard for environmental management.No.01 104 065607 GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 Commercial Air Conditioner Business Units Midea Group Add: West region of Midea commercial air conditioner department,lndustry Avenue, Beijiao,Shunde,Foshan,Guangdong,P.R.China Postal code:528311 Tel:+86-757-22390820 Fax:+86-757-23270470 http://www.midea.com CQ Midea General Refrigeration Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 056786 http://www.mideaaircon.com Note:The data in this book may be changed without notice for further improvement on quality and performance. R410A DC Inverter VRF V4 Plus Series 50Hz MDV Operating under the corporate umbrella of Midea Group, MDV is a professional climate control brand that produces different types and classes of air-conditioning systems for application in a wide range of scenarios. Founded in 1999, MDV emerged from Midea’s CAC (Commercial Air-Conditioning) division as a professional indoor climate solution provider and distributor to specialist companies across the globe. Initially, the MDV product portfolio comprised high-tech systems and components for commercial and industry application; for example, VRF (variable refrigerant flow) systems, chillers and fan-coils, compressor condensing units, light commercial air-conditioners. MDV then expanded into ODM manufacturing, and currently only outputs own-brand products. MDV has successfully deployed its solutions in numerous countries worldwide including Russia, Spain, Brazil, Australia, Israel, Bulgaria, Poland, Turkey, and Saudi Arabia. MDV has sought to establish a unique strategy and market position based on a philosophy of differentiation that implements standardized marketing, packaging, logo use, and visual branding concepts and designs. MDV has also expanded its global footprint, seeking wider international cooperation to strengthen its global brand equity as a leading provider indoor climate control solutions. 2004 2009 2007 2000 2011 2012 Year 1999 2001 2006 2008 2010 2012 Formed Midea-Carrier JV. Company in India and HK 2011 Formed Midea-Carrier JV. Company in Brazil 2010 Built the 3rd manufacturing base in Hefei 2009 Launched the DC inverter V4 system globally 2008 JV with Toshiba Carrier for the DC inverter technology 2007 Won the first Midea centrifugal chiller project oversea 2006 Launched the first VSD centrifugal chiller 2004 Acquired MGRE entered the chiller industry 2001 Partnered with Copeland to develop the digital scroll VRF system 2000 Developed the first inverter VRF With Toshiba 1999 Entered the CAC field Outdoor Units Lineup V4 Plus Heat Pump Capacity Range HP 8 10 12 14 16 KW 25.2 28.0 33.5 40.0 45.0 Capacity Range HP 8 10 12 14 16 KW 25.2 28.0 33.5 40.0 45.0 21 Mini VRF Appearance 33 Indoor units lineup V4 Plus Cooling Only HP 8 10 12 14 16 KW 25.2 28.0 33.5 40.0 45.0 88 Accessories HRV HRV Capacity Range 84 HRV Control system Control system 63 Control systems Indoor units lineup Indoor units lineup 05 V4 plus series Mini VRF Mini VRF Contents V4 Plus Corrosion Resistance V4 plus series V4 plus series Appearance Appearance Accessories Accessories Full DC Inverter Mini VRF Capacity Range HP 2.5 3 4 5 6 KW 8 10.5 12.3 14 16 Appearance V4 PLUS Series - V4 Plus, V4 Plus CR, V4 Plus C Model (capacity) o N of outdoor o N of units compressors Capacity o Maximum N (kW) of connectable indoor units Cooling Heating 2 13 25.2 27 1 2 16 28 31.5 33.5 1 2 16 33.5 37.5 14 40.0 1 3 16 40 45 16 45.0 1 3 20 45 50 18 53.2 2 4 20 53.2 58.5 20 56.0 2 4 24 56 63 22 61.5 2 4 24 61.5 69 24 68.0 2 5 28 68 76.5 26 73.0 2 5 28 73 81.5 28 80.0 2 6 28 80 90 30 85.0 2 6 32 85 95 32 90.0 2 6 32 90 100 34 96.0 3 7 36 96 108 36 101.0 3 7 36 101 113 38 106.5 3 7 36 106.5 119 40 113.0 3 8 42 113 126.5 42 120.0 3 9 42 120 135 44 125.0 3 9 42 125 140 46 130.0 3 9 48 130 145 48 135.0 3 9 48 135 150 50 143.2 4 10 54 143.2 158.5 52 146.0 4 10 54 146 163 54 151.5 4 10 54 151.5 169 56 158.0 4 11 58 158 176.5 58 165.0 4 12 58 165 185 60 170.0 4 12 58 170 190 62 175.0 4 12 64 175 195 64 180.0 4 12 64 180 200 HP kW 8 25.2 1 10 28.0 12 V4 plus series V4 plus series Developed to facilitate more flexible system design for big-sized and high-rise buildings V4 PLUS SERIES VRF product, which is designed to optimize the system and better satisfying the market. Offering a higher capacity up to 64HP by combining maximum four outdoor units, in 2HP as an increment. Three types of units are included: V4 Plus Heat Pump Units (”V4+”), V4 Plus Corrosion Resistance Heat Pump Units (”V4+CR”) and V4 Plus Cooling Only Units (”V4+C”). Recommended combination table Notes: Capacities are based on the following conditions: Cooling: Indoor temperature 27°C(80.6°F) DB/19°C(66.2°F) WB; Outdoor temperature 35°C(95°F) DB/24°C(75.2°F) WB Heating: Indoor temperature 20°C(68°F) DB/15°C(59°F) WB; Outdoor temperature 7°C(44.6°F) DB/6°C(42.8°F) WB Piping length: Interconnecting piping length is 7.5m, level difference is zero. The above combination models are factory-recommended models. 05 06 Features Wide operation Range Wide Application Range Large capacity for big sized building 48°C Outdoor Temperature HEATING MODE* The outdoor units capacity range from 8HP up to 64HP in 2HP increment. Maximum 64 indoor units with capacity up to 130% of total outdoor units can be connected in one refrigeration system. -20°C -2 0 18, 20, 22, 2 4, 26, 28, 30, 32HP 12, 14, 16HP 27°C Outdoor Temperature -1 0 0 10 20 30 40 V4 plus series V4 plus series 8, 10HP COOLING MODE -5°C 50 Outdoor temp. °C(D.B.) The V4+ series system operates stably at extreme temperatures ranging from -20°C to 48°C. *V4 Plus C system is without HEATING MODE. Large connectable indoor units quantity 07 ≤30HP 350m >30HP 500m Actual length 150m Equivalent length 175m Total pipe length*(Actual) Piping length Maximum piping(L) Level difference Piping (farthest from the first line pipe branch) equivalent length 40m Outdoor unit up 70m* Outdoor unit down 70m Level difference between ODU-IDU 15m Level difference between IDU-IDU *Total pipe length is equal to gas pipe or liquid pipe length. *Level difference above 50m are not supported by default but are available on request for customized. 64 58 54 Extra high static pressure – Max. 60Pa and air volume increased by 10% 48 42 36 32 28 24 20 16 The high-static pressure propeller and optimized fan guard can adapt to various installation environments. 60Pa MDV now offers up to 40Pa* external static pressure units for customized applications(60Pa is available for the 12HP model). A standard 0-20Pa 64HP 62HP 60HP 58HP 56HP 54HP 52HP 50HP 48HP 46HP 44HP 42HP 40HP 38HP 36HP 34HP 32HP 30HP 28HP 26HP 24HP 22HP 20HP 18HP 16HP 14HP 12HP function is equipped by default. 10HP 8HP 70 65 60 55 50 45 40 35 30 25 20 15 13 10 5 0 Permitted value Level difference between IDU-IDU is 15m Maximum piping actual length 150m 40m 50, 52, 54, 56, 58, 60, 62, 64HP 34, 36, 38, 40, 42, 44, 46, 48HP Level difference between IDU-ODU is 70m* Long piping length *You need to consult MDV if you require over 40Pa. 08 High Efficiency Higher Reliability Duty cycling In one combination, any outdoor unit can run as the master outdoor unit to equalize the service life of all units. The V4 PLUS Series with high efficient DC compressor, DC motor and high efficient heat exchanger, achieve the world’s Top Class energy efficiency. The cooling EER is up to 4.29 and the heating COP is up to 4.39 in the 8HP category. Enhanced rated heat capacity EER COP* 4.39 4.29 V4 plus series V4 plus series 3.89 3.7 3.25 3.21 4.17 4.14 4.02 3.91 Back-up function In a multiple system, when the master unit failed, any single unit can be set as the master unit,then the remaining units can keep on working. This can be set on PCB by DIP switches at site. 8HP 10HP 12HP 14HP 8HP 16HP 10HP 12HP 14HP 16HP *V4 Plus C system is without heating COP value High performance heat exchanger Original design Windage& air flow Reduce air resistance. High efficiency oil balance and oil return technology 0.8 0.6 0.4 Original design Reduce 28% 0.2 New design 0 0 200 400 600 800 1000 Re Refrigerant flow direction Frost contrast Oil separator Oil balance pipe between modules Oil even pipe II High efficiency inner-threaded pipe, enhance heat transfer. Relative windage resistance Enter condenser Discharge pipe Oil balance pipes among modules and individual oil balance by vector control ensure even oil distribution among the modules which keeps compressors running normally. High effciency centrifugal oil separator (separation efficiency up to 99%) makes oil separate from discharge gas and go back to compressors. Auto oil return program by monitoring the running time and state of system ensures reliable oil return. New design Relative windage resistance When the slave 1 failed and came into standby state, the left module can still work. 0.8 0.4 New design 0.2 0 0 0.2 Oil even pipe I From evaporator Reduce 30% Original design 0.6 0.4 0.6 0.8 1 Relative frosting rate Hydrophilic film fins + inner-threaded pipes Suction pipe The new designed window fins enlarge the heat-exchanging area , decrease the air resistance, save more power and enhance heat exchange performance. Hydrophilic film fins and inner-threaded copper pipes optimize heat exchange efficiency. 09 10 Easier Installation and Service Enhanced Comfort Intelligent soft start technology Starting current 600 500 DC inverter compressor soft start function reduces strike to the electric network. This kind of high-performance and low sound scroll compressor operates at a faster rate when starting, reducing start-up time. It also helps the unit to quickly adjust the room temperature to the set level. Compact design for effective use of space Direct start Y-△ start Start by inverter (%) 400 Easy to transport Compact size and light weight design minimizes the installation footprint, reduces the installation floor load, and is easier for transportation. For some projects the units can even be transported through the elevator or forklift, reduce access problem at the jobsite. Comparison of start by inverter and by traditional methods 300 200 100 1 2 3 4 5 6 (Sec) Fluctuation of room temperature V4 plus series V4 plus series Quick warm-up & cool-down design 1 By utilizing the benefits of the inverter compressor, the system can reach full load quickly and shorten the warm-up and cool-down times to provide an immediate and comfortable air solution. Less temperature fluctuation will create a better living environment. 2 Simple signal line connection Cooling operation Installation is easier as communication wiring can be shared by indoor & outdoor units . It’s easy for the user to retrofit the existing system with a centralized simply connecting to the outdoor units. Night silent operation mode MDV's Night Silent Mode feature which is easily set on the PCB board allows the unit to be set to varies time options during Non Peak and Peak operation time optimizing the units noise output. Extra silent operation mode can reduce sound level further, minimum 46.8dB (A). Night silent operation will be activated X hours after the peak temperature during daytime, and it will go back to normal operation after Y hours. X Y E -Model 2→X: 8 hours, Y: 10 hours -Model 4→X: 8 hours, Y: 8 hours PQ E Peak value of ambient temp. P Q E P Q E P Q E 100 50 Auto addressing Night silent Mode noise Max.-10dB(10Hp) Start 08:00 14:00 Notes: This function can be activated by setting at site. 22:00 08:00 Temperature(load) curve shown in the graph is just an example. The outdoor unit can automatically distribute the addresses to indoor units without any manual settings. Wireless controller can query and modify each indoor unit's address. 0 EF 1 23 45 Intelligent defrosting raises heat capacity* defrost End BCD 10hrs 8hrs 89A Noise dB X Y E 67 Load % Capacity % -Model 1→X: 6 hours, Y: 10 hours -Model 3→X: 6 hours, Y: 12 hours P Q E PQE & XYE: only one set of PQE communication wires can achieve communication among indoor units, outdoor units and the network. Reversible communication, central controller can be connected from indoor side or outdoor side as you wish. Need To Set The Address Manually, one By One Previous Design Improved on V4 plus Automatically Identify Easy access The checking window on electric control box for convenient spot checking and status enquiry. *V4 Plus C system is without this function. 11 Compressor is located near the door, which simplifies checks and enables valve or compressor parts to be replaced easily. 12 Technologies Smooth 180°sine wave DC Inverter High efficiency full DC inverter compressor Adopting the 180° Sine Wave Inverter to smooth motor rotation greatly improves operating efficiency compared with traditional sawtooth wave. High efficiency DC inverter compressor reduces power consumption by 25%. New structure-enhanced mid-frequency performance Specially designed scroll profile for R410A Advanced permanent magnet DC motor improves low-frequency band performance Common sawtooth wave 180° Sine Wave DC inverter DC fan motor Centralizing winding Distributing winding Efficiency-Rotor Speed Curve Compressor efficiency New DC motor-centralized winding Common DC motor-distributing winding 20 40 60 80 100 Used across entire range of models (from 8 to 64 HP). Efficiency improvement up to 45% especially at low speed. Wide speed adjustment with 18 steps vetor control. EFFICIENCY (%) According to the running load and pressure, it controls the speed of DC fan to achieve the minimum power consumption. Powerful magnets provide high torque and efficiency and achieve 70% reduction in volume. V4 plus series V4 plus series More compact, weight reduced by 50% DC motor 100 80 Increased by 45% 60 40 20 200 1000 MOTOR SPEED (RPM) Rotor speed(s-1) Fan speed control 18 steps vector control High Fan grille Optimized fan blade shape with new air outlet grille enhanced air flow volume which greatly improves fan performance and decreases noise. Also, a higher external static pressure has been achieved up to 60Pa*. (0-20Pa is standard, 20~40Pa should be customized.) *:60Pa is available for 12HP model. New profile fan blade A new blade with sharp edges and a slight curve increases the airflow rate and lowers vibration and airflow resistance. 13 Low Multi solenoid valves control technology Multi solenoid valves control technology in one system. All the solenoid valves equipped in the unit ensure temperature-control precisely, system running steadily and economic to provide a comfortable environment. 14 Specifications Specifications V4 Plus Heat Pump Unit MDV-252(8)W/ DRN1(B) Model MDVC-400(14)W /DRN1(B) MDVC-450(16)W /DRN1(B) 380~415V 3Ph ~ 50Hz 380~415V 3Ph ~ 50Hz 380~415V 3Ph ~ 50Hz 380~415V 3Ph ~ 50Hz 7.2 8.0 9.5 11.4 12.8 kW 25.2 28 33.5 40 45 kW 25.2 28 33.5 40 45 Btu/h 86,000 95,500 114,300 136,500 153,500 kcal/h 21,672 24,080 28,810 34,400 38,700 Input kW 5.87 7.2 9.05 12.31 14.02 EER kW/kW 4.29 3.89 3.7 3.25 3.21 RT 7.7 8.9 10.7 12.8 14.2 380~415V 3Ph ~ 50Hz 380~415V 3Ph ~ 50Hz 380~415V 3Ph ~ 50Hz 380~415V 3Ph ~ 50Hz 380~415V 3Ph ~ 50Hz V4 plus series kW 27 31.5 37.5 45 50 Btu/h 92,100 107,500 128,000 153,500 170,600 kcal/h 23,220 27,090 32,250 38,700 43,000 Input kW 6.15 7.61 8.99 11.19 12.79 COP kW/kW 4.39 4.14 4.17 4.02 3.91 % 50-130 50-130 50-130 50-130 50-130 13 16 16 16 20 Total Capacity Max. Quantity dB(A) 57 57 58 60 60 mm Ф12.7 Ф12.7 Ф15.9 Ф15.9 Ф15.9 Gas pipe mm Ф25.4 Ф25.4 Ф31.8 Ф31.8 Ф31.8 Oil balance pipe mm Ф6.5 Ф6.5 Ф6.5 Ф6.5 Ф6.5 Motor type DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter Quantities 1 1 2 2 2 3 m /h 11,700 11,700 15,600 15,600 15,600 CFM 6,880 6,880 9,173 9,173 9,173 W 750 750 575×2 575×2 575×2 Axial propeller Axial propeller Axial propeller Axial propeller Axial propeller Motor output ESP Pa 0~20 (default) 0~20 (default) 0~20 (default) 0~20 (default) 0~20 (default) 20~40 (customized) 20~40 (customized) 20~60 (customized) 20~40 (customized) 20~40 (customized) Quantities Capacity Btu/h 86,000 95,500 114,300 136,500 153,500 kcal/h 21,672 24,080 28,810 34,400 38,700 Input kW 5.87 7.2 9.05 12.31 14.02 EER kW/kW 4.29 3.89 3.7 3.25 3.21 % 50-130 50-130 50-130 50-130 50-130 13 16 16 16 20 Cooling Connectable I ndoor Unit Total Capacity Max. Quantity Sound Pressure Level dB(A) 57 57 58 60 60 mm Ф12.7 Ф12.7 Ф15.9 Ф15.9 Ф15.9 Gas pipe mm Ф25.4 Ф25.4 Ф31.8 Ф31.8 Ф31.8 Oil balance pipe mm Ф6.5 Ф6.5 Ф6.5 Ф6.5 Ф6.5 DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter Liquid pipe Pipe Connections Motor type Quantities Air Flow Rate Outdoor fan motor Motor output 1 1 2 2 2 m3/h 11,700 11,700 15,600 15,600 15,600 CFM 6,880 6,880 9,173 9,173 9,173 750 750 560× 2 560× 2 560× 2 Axial Axial Axial Axial Axial 0~20 (default) 0~20 (default) 0~20 (default) W Fan type ESP Pa Quantities DC Inverter compressor Capacity W 0~20 (default) 20~40(customized) 0~20 (default) 20~40(customized) 20~60(customized) 20~40(customized) 20~40(customized) 1 1 1 1 1 11800 11800 11800 11800 11800 Crankcase heater W 27.6×2 27.6×2 27.6×2 27.6×2 27.6×2 Refrigerant oil ml FVC68D /500 FVC68D /500 FVC68D /500 FVC68D /500 FVC68D /500 1 1 1 1 1 Capacity W 11,800 11,800 11,800 11,800 11,800 Quantities 1 1 1 2 2 Crankcase heater W 27.6×2 27.6×2 27.6×2 27.6×2 27.6×2 Capacity W 15390 15500 15500 15500×2 15500×2 Refrigerant oil ml FVC68D / 500 FVC68D / 500 FVC68D / 500 FVC68D / 500 FVC68D / 500 Crankcase heater W 27.6 27.6 27.6 27.6×2 27.6×2 1 1 1 2 2 Refrigerant oil ml FVC68D / 500 FVC68D /500 FVC68D /500 FVC68D /500×2 FVC68D /500×2 R410A R410A R410A R410A R410A 10 10 12 15 15 Quantities Capacity W 15,390 17,100 17,100 15,390×2 17,100×2 Crankcase heater W 27.6 27.6 27.6 27.6×2 27.6×2 Refrigerant oil ml FVC68D / 500 FVC68D / 500 FVC68D / 500 FVC68D / 500×2 FVC68D / 500×2 R410A R410A R410A R410A R410A Type Factory Charging kg 10 10 12 15 MPa 4.4/2.6 4.4/2.6 4.4/2.6 4.4/2.6 4.4/2.6 Net (W×H×D) mm 960×1,615×765 960×1,615×765 1,250×1,615×765 1,250×1,615×765 1,250×1,615×765 Packing Size (W×H×D) mm 1,025×1,790×830 1,025×1,790×830 1,305×1,790×820 1,305×1,790×820 1,305×1,790×820 kg 245 245 275 325 Design Pressure (Hi/Lo) Net Fixed scroll compressor Refrigerant Gross weight kg 260 260 295 345 Cooling °C -5°C-48°C -5°C-48°C -5°C-48°C -5°C-48°C -5°C-48°C 345 Heating °C -20°C-27°C -20°C-27°C -20°C-27°C -20°C-27°C -20°C-27°C Factory Charging Design Pressure (Hi/Lo) 15 325 Type Unit Dimension Unit weight kg MPa 4.4/2.6 4.4/2.6 4.4/2.6 4.4/2.6 4.4/2.6 Net (W×H×D) mm 960×1615×765 960×1615×765 1250×1615×765 1250×1615×765 1250×1615×765 Packing Size (W×H×D) mm 1025×1790×830 1025×1790×830 1310×1790×825 1310×1790×825 1310×1790×825 Net kg 245 245 275 325 325 Gross weight kg 260 260 295 345 345 °C -5°C-48°C -5°C-48°C -5°C-48°C -5°C-48°C -5°C-48°C Operating Temp. Range- cooling V4 plus series 380~415V 3Ph ~ 50Hz Fan type Operating Temp. Range MDVC-335(12)W /DRN1(B) RT Air Flow Rate Unit weight MDVC-280(10)W /DRN1(B) V-Ph-Hz Liquid pipe Unit Dimension Power supply MDVC-252(8)W /DRN1(B) 12.8 Sound Pressure Level Refrigerant Model 11.4 Heating Fixed scroll compressor MDV-450(16)W/ DRN1(B) 9.5 Capacity DC Inverter compressor MDV-400(14)W/ DRN1(B) 8.0 Cooling Outdoor fan motor MDV-335(12)W/ DRN1(B) 7.2 V-Ph-Hz Capacity Pipe Connections MDV-280(10)W/ DRN1(B) RT Power supply Connectable Indoor Unit V4 Plus Cooling Only Unit Notes: 1.Nominal conditions Notes: 1.Nominal conditions Cooling Indoor Outdoor Pipe length Level difference 27°C DB(80.6°F), 19°C WB(60°F) 35°C DB(95°F) 7.5m 0m Indoor Outdoor Pipe length Level difference Cooling 27°C DB(80.6°F), 19°C WB(60°F) 35°C DB(95°F) 7.5m 0m 2.Sound level: Anechoic chamber conversion value, measured at a position 1m in front of the unit and 1.5m above the floor. Heating 20°C DB(68°F), 15°C WB(44.6°F) 7°C DB(42.8°F) 7.5m 0m 3.Refrigerant pipe dim.listed here only for when the total equivalent length<90m. For the data when total quivalent length≥90 please refer to technical manual. 4.The above data may be changed without notice for further improvement on quality and performance. 2.Sound level: Anechoic chamber conversion value, measured at a position 1m in front of the unit and 1.5m above the floor. 3.Refrigerant pipe dim.listed here only for when the total equivalent length <90m. For the data when total quivalent length ≥90 please refer to technical manual. 4.The above data may be changed without notice for further improvement on quality and performance. 15 16 V4 Plus Corrosion Resistance Unit The V4 Plus CR VRF unit adopts corrosion-resistance materials on both metal and electronic parts make it can be installed near the sea. The system is capable of cooling and heating, and provides a long piping length and high elevation design. V4 Plus is an energy saving and highly efficient inverter system. It provides the convenience of individual control and precise control functionality on indoor load conditions. Specifications V4 Plus Corrosion Resistance Unit MDV-252(8)W/ DRN1(B)-CR MDV-280(10)W/ DRN1(B)-CR MDV-335(12)W/ DRN1(B)-CR MDV-400(14)W/ DRN1(B)-CR MDV-450(16)W/ DRN1(B)-CR V-Ph-Hz 380~415V 3Ph ~ 50Hz 380~415V 3Ph ~ 50Hz 380~415V 3Ph ~ 50Hz 380~415V 3Ph ~ 50Hz 380~415V 3Ph ~ 50Hz RT 7.2 8.0 9.5 11.4 12.8 kW 25.2 28 33.5 40 45 Btu/h 86,000 95,500 114,300 136,500 153,500 Model Power supply Capacity Cooling 21,672 24,080 28,810 34,400 38,700 kW 5.87 7.2 9.05 12.31 14.02 EER kW/kW 4.29 3.89 3.7 3.25 3.21 RT 7.7 8.9 10.7 12.8 14.2 kW 27 31.5 37.5 45 50 Btu/h 92,100 107,500 128,000 153,500 170,600 Capacity Heating The plastic planting grille protects against salt. All panel parts are corrosion resistant to protect against brine. Connectable Indoor Unit kcal/h 23,220 27,090 32,250 38,700 43,000 Input kW 6.15 7.61 8.99 11.19 12.79 COP kW/kW 4.39 4.14 4.17 4.02 3.91 % 50-130 50-130 50-130 50-130 50-130 13 16 16 16 20 dB(A) 57 57 58 60 60 mm Ф12.7 Ф12.7 Ф15.9 Ф15.9 Ф15.9 Gas pipe mm Ф25.4 Ф25.4 Ф31.8 Ф31.8 Ф31.8 Oil balance pipe mm Ф6.5 Ф6.5 Ф6.5 Ф6.5 Ф6.5 DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter Total Capacity Max. Quantity Sound Pressure Level Liquid pipe Pipe Connections Type Quantities Air Flow Rate Outdoor fan motor Motor output 1 1 2 2 2 m3/h 11,700 11,700 15,600 15,600 15,600 CFM 6,880 6,880 9,173 9,173 9,173 W 750 750 750×2 750×2 750×2 Axial propeller Axial propeller Axial propeller Axial propeller Axial propeller 0~20 (default) 0~20 (default) 0~20 (default) 0~20 (default) 0~20 (default) 20~40 (customized) 20~60 (customized) 20~40 (customized) 20~40 (customized) Fan type Corrosion resistant heat-exchange fins are suitable for seaside areas and areas exposed to acidic substances. ESP Pa Quantities DC Inverter compressor Capacity W Refrigerant All screws are anti-rust. Unit weight Operating Temp. Range 1 1 1 1 1 11,800 11,800 11,800 11,800 11,800 W 27.6 27.6 27.6 27.6 27.6 Refrigerant oil ml FVC68D / 500 FVC68D / 500 FVC68D / 500 FVC68D / 500 FVC68D / 500 1 1 1 2 2 W 15,390 17,100 17,100 15,390×2 17,100×2 Capacity Crankcase W 27.6 27.6 27.6 27.6×2 27.6×2 Refrigerant oil ml FVC68D / 500 FVC68D / 500 FVC68D / 500 FVC68D / 500×2 FVC68D / 500×2 R410A Type R410A R410A R410A R410A kg 10 10 12 15 15 MPa 4.4/2.6 4.4/2.6 4.4/2.6 4.4/2.6 4.4/2.6 Net (W×H×D) mm 960×1,615×765 960×1,615×765 1,250×1,615×765 1,250×1,615×765 1,250×1,615×765 Packing Size (W×H×D) mm 1,025×1,790×830 1,025×1,790×830 1,305×1,790×820 1,305×1,790×820 1,305×1,790×820 325 Factory Charging Design Pressure (Hi/Lo) Unit Dimension 20~40 (customized) Crankcase Quantities Fixed scroll compressor V4 plus series V4 plus series kcal/h Input Net kg 245 245 275 325 Gross weight kg 260 260 295 345 Cooling °C -5°C-48°C -5°C-48°C -5°C-48°C -5°C-48°C -5°C-48°C Heating °C -20°C-27°C -20°C-27°C -20°C-27°C -20°C-27°C -20°C-27°C 345 Notes: All PCB parts in the unit are coated with double-sided moisture proof paint. The outer side of the control box metal cover is spray-painted. 1.Nominal conditions Indoor Outdoor Pipe length Level difference Cooling 27°C DB(80.6°F), 19°C WB(60°F) 35°C DB(95°F) 7.5m 0m Heating 20°C DB(68°F), 15°C WB(44.6°F) 7°C DB(42.8°F) 7.5m 0m 2.Sound level: Anechoic chamber conversion value, measured at a position 1m in front of the unit and 1.5m above the floor. 3.Refrigerant pipe dim.listed here only for when the total equivalent length<90m. For the data when total quivalent length≥90 please refer to technical manual. 4.The above data may be changed without notice for further improvement on quality and performance. 17 18 Dimensions Installation dimensions (Unit: mm) Body dimensions (Unit: mm) Outdoor Unit 12/14/16 HP 1615 V4 plus series Φ10 Expansion bolt Rubber shocking proof mat Concrete basement h=200mm Solid ground or roofing 200mm 960 765 1250 765 Screw Bolt Position B C Pipe connection (Unit: mm) D A 15×23 long u-shape hole Liquid side A B Gauge point Cooling only type without HP 8/10 12/14/16 A 830 1120 B 960 1250 C 736 736 D 765 765 SIZE Oil balancer For parallel connect the modular units Notes: (1) Ensure that the outdoor unit is installed in a dry, well-ventilated place. Gas side (2) Ensure that the noise and exhaust ventilation of the outdoor unit do not affect the neighbors of the property owner or the surrounding ventilation. (3) Ensure that the outdoor unit is installed in a well-ventilated place that is possibly closest to the indoor unit. F E D V4 plus series 1615 8/10 HP (4) Ensure that the outdoor unit is installed in a cool place without direct sunshine exposure or direct radiation of high-temp heat source. (5) Do not install the outdoor unit in a dirty or severely polluted place, so as to avoid blockage of the heat exchanger in the outdoor unit. R: Pipe Connection (6) Do not install the outdoor unit in a place with oil pollution or full of harmful gases such as sulfurous gas. C R Section View (7) Do not install the outdoor unit in a place surrounded by salty air. (Except for the models with corrosion-resistant function.) HP SIZE 8 10 12 14 16 A 199 199 169 169 169 B 159 159 209 209 209 C 195 195 169 169 169 D 168 168 168 168 168 E 208 208 208 208 208 F 220 220 Liquid pipe ODΦ12.7 ODΦ12.7 Gas pipe 19 ODΦ25.4 ODΦ25.4 220 220 220 ODΦ15.9 ODΦ15.9 ODΦ15.9 ODΦ31.8 ODΦ31.8 ODΦ31.8 20 Full DC Inverter Mini VRF Full DC Inverter Mini VRF with DC inverter compressor and DC fan motor delivers a highly efficient solution for small commercial buildings. Four to seven rooms require only one outdoor unit, and individual control is enabled in each room. Features MDV's continuous technological innovations fully meets current market needs. All of this year's new technologies have been developed to provide the most efficient and convenient air conditioners. High efficiency full DC inverter compressor High efficiency and Energy-saving, thanks to the DC inverter compressor and DC fan motor. Inverter systems save energy as continuous operation offers the same capacity as lower power consumption. This benefits all occupants by maintaining even room temperatures, as well as the environment by reducing energy consumption. Highly Efficient DC Motor: - Creative motor core design - High density neodymium magnet - Concentrated type stator Mini VRF Mini VRF -Wider operating frequency range Better balance and Extremely Low Vibration: - Twin eccentric cams - 2 balance weights Highly Stable Moving Parts: - Optimal material matching rollers and vanes Compressor (Twin Rotary) structure -Optimize compressor drive technology - Highly robust bearings -Compact structure Powerful magnets provide high torque and efficiency and achieve 70% reduction in volume. Centralizing winding Efficiency-Rotor Speed Curve Compressor efficiency Distributing winding New DC motor-centralized winding Common DC motor-distributing winding 20 40 60 80 Rotor speed(s-1) 100 Low noise DC fan motor DC fan motor structure DC motor efficiency Panasonic DC fan motor : -lower noise -lower power consumption NEW Fashion Design 21 EFFICIENCY (%) -Wider fan speed adjustment 100 (comparison with a conventional AC motor) 80 60 40 20 0 200 DC motor Approx. 20% increase Approx. 40% increase 300 AC motor 400 500 600 700 800 900 1000 MOTOR SPEED (RPM) 22 High corrosion resistance heat exchanger Auto addressing The coils are specially coated to enhance durability and protect against corrosion from air, water and other corrosive agents. The blue fin coil provides three times higher resistance against corrosion. This special coating assures a longer coil service life to provide years of comfort for users. The outdoor unit can automatically distribute the addresses to indoor units without any manual settings. Wireless controller can query and modify each indoor unit's address. Outdoor unit can distribute address for indoor unit. Shield signal wire Noise reducing design KJR-29B Optimally designed fan shape and air discharge grille increases air volume and reduces running noise. RM05 More convenience in installation New grille Front side Right side Back side Mini VRF Mini VRF A four-direction space is available for connecting pipes and wiring in various installation scenarios. Air deflector Bottom side Fat pipe back side New fan Newly Designed Fan Guard Powerful Large Propeller Application flexibility-various Indoor units Mini VRF with intelligent control gives you independent zoning control with maximum flexibility.A single outdoor unit supports up to seven indoor units, freeing up considerable space outside.Use your backyard more wisely with much more space available created by less number of outdoor units. Max. 4 indoor units for a 8.0 kW outdoor unit installation Max. 5 indoor units for a 10.5 kW outdoor unit installation Max. 6 indoor units for a 12.3 kW outdoor unit installation Max. 6 indoor units for a 14 kW outdoor unit installation Max. 7 indoor units for a 16 kW outdoor unit installation For installation in different types of rooms in small offices and shops,the Mini VRF system offers a wide range of indoor and outdoor units. These are almost as easy to install as residential air conditioning systems, making them the ideal choice. Front side Bottom side Benefits of R410A refrigerant Comparison of refrigerant boiling points (liquid and gas) 0 32 14 -4 -22 -40 -58 -76 -61.24 -55.3 -15.12 R32 R125 R134a High boiling point Approximately same boiling point Blend of two types with similar boiling points Blend of three types with different boiling points 03 23 Right side R410A Degradation unlikely R407C Degradation likely In line with our green strategy, MDV's air conditioners use ozone-friendly R-410A refrigerant to eliminate pollutants and limit the use of materials with high global warming potential (GWP). R410A delivers multiple benefits: Causes zero ozone depletion Significantly increases energy efficiency. Reduces pressure loss to improve performance. 04 24 Wide operation temperature range Flexible piping design Up to 48°C in cooling mode and down to -15°C in heating mode. The Mini VRF provides a max. piping length possibility of 100m, a maximum height difference between outdoor and indoor units of 30m. The height difference between indoors unit can be up to 8m. These generous allowances facilitate an extensive array of system designs. The operation range of the Mini VRF system works to reduce limitations on installation locations. The wide operation range of the Mini VRF system greatly increases the number of possible installation locations where the system can run stably. COOLING MODE -15°C 48°C HEATING MODE 27°C -15°C -20 -10 0 10 20 30 40 50 The longest piping length : 70m.* 2 (Equivalent Length) Mini VRF Mini VRF Outdoor temp. °C(D.B.) Level differences between indoor & outdoor units : 30m.*1 Mini VRF system operates stably at extreme temperatures ranging from minus 15°C to 48°C The first branch joint to the farthest indoor unit : 20m. Smooth control By using all inverter-driven compressors, MDV is able to significantly reduce the electrical and mechanical stresses that are placed on fixed-speed compressors during start-up. Current absorption on an inverter-driven compressor is smoothed out at start-up thus reducing the wear on the electrical and mechanical components and increasing reliability. Level difference between indoor units : 8m. The indoor unit from the nearest branch pipe: 15m. Start-up using all inverter-driven compressor Compressor drive Fixed-speed unit: sudden start-up Fixed-speed unit: 5-7 times drive current Compressor current No more than inverter drive current Inverter: gradual start-up Piping stress Inverter: almost same as during normal drive Start > Drive 25 8/10.5kW 12.3/14/16kW Actual length ≤45m ≤60m Equivalent length ≤50m ≤70m Total piping length: 100m. Start > Drive Fixed-speed unit: c. 3 times normal drive Note:*1.when outdoor unit up level difference is 30m.,when outdoor unit down level difference is 20m. *2.Longest piping length Auto-restart function Start > Drive Compressor oil surface Inverter Fixed-speed unit Even if an extended power failure occurs, the A/C system automatically restarts with the same settings. A power failure will not cause any settings to be lost, thus eliminating the need for re-programming. Compressor Before start-up Easy maintenance After start-up Little lowering of oil surface Temporary fall in oil surface due to sudden outflow of refrigerant and oil Forced cooling button makes outdoor unit run in cooling mode at any condition, so it is very easy for you to charge refrigerant to the system when it need to be done. The self-diagnosis function detects malfunctions in major locations in the system and displays the type of malfunction and location. This allows service and maintenance to be performed more efficiently. 26 Space saving design More convenient piping connector - branch box The Mini VRF units are slimmer and more compact, resulting in significant savings in installation space. In some large residential and light commercial areas, such as villas, restaurants, usually it need more than one indoor unit, which in turn requires multiple outdoor units. MDV's MINI VRF system removes this problem, and retains buildings' original aesthetics. Easier and safer installation thanks to a branch box that simplifies piping work and the adoption of screw connection. Both left and right pipe flare connectin from outdoor unit to branch box is reserved, which greatly simplifies field installation. Two sets of pipe size converter are packed with branch box to transfer the pipe size from Φ6.35mm to Φ9.53mm and from Φ12.7mm to Φ15.9mm. Low noise The branch pipe is linear expansion design regulates the flow of refrigerant and reduces the noise. By locating the branch box in the ceiling or outside ,noise generated by the branch box can be kept clear of living spaces, thus maintaining the noise level to a minimum. Mini VRF Mini VRF Brazing-free quick installation All the piping leading to and from the branch box is connected using flare nut connection,which can be installed quickly and easily. Indoor installation Easy installation Easy to transport The branch box can be installed in the ceiling rather than outside. Removing the side and bottom covers provides easy access for maintaining inner components such as circuit boards. No need special room for the outdoor units. Easy installation: No special area is required for outdoor units. All outdoor units can be transported by elevator, which greatly simplifies installation and New piping connection design reduces time and labor. The Mini VRF system's indoor and outdoor units are almost as easy to install as residential air conditioning systems, making them ideal for small offices and shops. Comfortable temperature The inverter Mini VRF can quickly reach Non Inverter High Temperature Fluctuation the desired temperature. After reaching the set temperature, it finely adjusts to cope with any changes. This means less temperature fluctuations to achieve Uncomfortable (Energy Loss) 82 F Comfortable 78.7 F maximum comfort in minutes. Uncomfortable (Energy Loss) 75.5 F 27 S-Inverter Steady Temperature Fluctuation 28 Outdoor Unit Outdoor Unit Specifications Specifications 220-240V~50Hz 220-240V~50Hz 380-415V-3N~50Hz MDV-V80W/DN1 MDV-V120W/DN1 MDV-V120W/DRN1 MDV-V105W/DN1 MDV-V140W/DN1 MDV-V140W/DRN1 MDV-V160W/DN1(B) MDV-V160W/DRN1 Model V-Ph-Hz Power supply Capacity* Cooling Input Capacity* Heating Input COP 8 10.5 27300 35800 Kcal/h 6824 9042 kW 2.05 2.68 kW/kW 3.90 3.92 Outdoor fan motor Outdoor unit Dimension Weight Refrigerant Connection wiring Power supply Capacity* Cooling 220-240V~50Hz 220-240V~50Hz MDV-V120W/DRN1 MDV-V140W/DRN1 MDV-V160W/DRN1 V-Ph-Hz 380-415V-3N~50Hz 380-415V-3N~50Hz 380-415V-3N~50Hz kW 12.3 14 15.5 Btu/h 42000 47800 52900 Kcal/h 10580 12063 13355 Input kW 3.25 3.95 4.52 EER kW/kW 3.78 3.54 3.43 kW 13.2 15.4 17 9906 Kcal/h 7752 kW 2.24 2.9 kW/kW 4.02 3.97 45%~130% 45%~130% Input 4 5 COP Input W 2200 3010 Refrigerant oil ml FV50S 670ml+200ml FV50S 670ml+200ml 3 3600 5100 m /h CFM 2120 3000 mm Ф9.52 Ф9.52 m Ф15.9 Ф15.9 Type DC motor DC motor Brand Panasonic Panasonic W Type 72 72 Axial fan Axial fan Body(W×H×D) mm 1075×966×396 1075×966×396 Packing (W×H×D) mm 1120×1100×435 1120×1100×435 Net weight(220V/380V) kg 62 72 Gross weight(220V/380V) kg 67 79 R410A R410A 2800 3000 Type g 2 Power Wiring(220V) mm Signal wiring mm 2 Capacity* Heating 3 core×4.0 3 core×4.0 3 core shielded wire×0.75 Indoor unit connectable Note: 1. The cooling conditions: indoor temp.: 27°CDB(80.6°F), 19°CWB(60°F) outdoor temp.: 35°CDB(95°F) equivalent pipe length: 5m drop length: 0m. 2. The heating conditions: indoor temp.: 20°CDB(68°F), 15°CWB(44.6°F) outdoor temp.: 7°CDB(42.8°F) equivalent pipe length: 5m drop length: 0m. 3. Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of *m(0.9m for 80model, 1m for 105 model,1.2m for 120~160model). During actual operation, these values are normally somewhat higher as a result of ambient conditions. 4. The above data may be changed without notice for future improvement on quality and performance. Btu/h 45000 52500 58000 Kcal/h 11373 13269 14647 kW 3.47 4.16 4.77 kW/kW 3.80 3.70 3.56 % 45%~130% 45%~130% 45%~130% 6 6 7 dB(A) 57 57 57 Rotary Max. quantity of indoor units Sound pressure level* Rotary Rotary Input W 3010 3010 4240 Refrigerant oil ml FV50S 870ml+630ml FV50S 870ml+630ml FV50S 1400ml+250ml m /h 3 6000 6000 6000 CFM 3531 3531 3531 Liquid side mm Ф9.52 Ф9.52 Ф9.52 Gas side m Ф15.9 Ф15.9 Ф15.9 DC motor DC motor DC motor Type Compressor Outdoor air flow Refrigerant piping Type Outdoor fan motor Panasonic Panasonic Panasonic W 2×85 2×85 2×85 Axial fan Axial fan Axial fan Body(W×H×D) mm 900×1327×320 900×1327×320 900×1327×320 Packing (W×H×D) mm 1030×1456×435 1030×1456×435 1030×1456×435 Brand Output Outdoor fan Outdoor unit Dimension Weight Refrigerant Connection wiring 29 220-240V~50Hz 11.5 57 Charged volume V-Ph-Hz Model 39200 Rotary Output Outdoor fan MDV-V160W/DN1(B) 9 56 Gas side MDV-V140W/DN1 30700 Rotary Liquid side Power supply MDV-V120W/DN1 kW dB(A) Outdoor air flow Model Btu/h Type Sound pressure level* Refrigerant piping 220-240V~50Hz kW Max. quantity of indoor units Compressor 220-240V~50Hz Btu/h % Indoor unit connectable MDV-V105W/DN1 Type Net weight(220V/380V) kg 95/95 95/95 100/102 Gross weight(220V/380V) kg 106/106 106/106 111/113 R410A R410A R410A g 3300 3900 3900 Power Wiring(220V) mm2 3 core×4.0 3 core×4.0 3 core×4.0 PoweR Wiring(380V) mm2 5 core×2.5 5 core×2.5 5 core×2.5 Signal wiring mm2 Type Charged volume Mini VRF Mini VRF EER MDV-V80W/DN1 3 core shielded wire×0.75 Note: 1. The cooling conditions: indoor temp.: 27°CDB(80.6°F), 19°CWB(60°F) outdoor temp.: 35°CDB(95°F) equivalent pipe length: 5m drop length: 0m. 2. The heating conditions: indoor temp.: 20°CDB(68°F), 15℃WB(44.6°F) outdoor temp.: 7°CDB(42.8°F) equivalent pipe length: 5m drop length: 0m. 3. Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of *m(0.9m for 80model, 1m for 105 model,1.2m for 120~160model). During actual operation, these values are normally somewhat higher as a result of ambient conditions. 4. The above data may be changed without notice for future improvement on quality and performance. 30 Unit installation >60cm Unit Dimensions (unit:mm) Single Unit installation (Wall or obstacle) Air inlet >300 Dimension >300 966 Fix with bolt Air inlet >600 Air outlet 396 336 366 >2000 624 354 Maintain channel Parallel installation Mini VRF Mini VRF 990 >2000 >300 1075 >500 >3000 >3000 >300 >600 >2000 360 400 320 1327 348 600 Fat pipe Front out pipe 900 R 31 Side out pipe Back out pipe Undersurface out pipe R amplification 32 Indoor Units Lineup Indoor units lineup Indoor Units Lineup One-way Cassette Two-way Cassette Compact Four-way Cassette Four-way Cassette Low Static Pressure Unit Concealed Duct Unit (A5 Type) High Static Pressure Duct Ceiling & Floor Type Wall-mounted S Type Wall-mounted C Type Wall-mounted R Type Floor Standing Console Fresh Air processing Unit 34 38 Model Type 18 22 28 36 45 56 71 80 90 100 112 125 140 160 200 250 280 400 450 560 (capacity *100 ) One-way cassette Two-way cassette Compact fourway cassette MDV-D XX Q1/N1-C MDV-D XX Q2/N1 MDV-D XX Q4/N1-A3 Four-way cassette MDV-D XX Q4/N1-D Low Static Pressure Duct MDV-D XX T3/N1-B Concealed Duct Unit(A5 Type) MDV-D XX T2/N1-BA5 MDV-D XX T1/N1-B Ceiling & Floor Type MDV-D XX DL/N1-C Wall-mounted S Type MDV-D XX G/N1-S MDV-D XX G/DN1-S Wall-mounted C Type MDV-D XX G/N1YB MDV-D XX G/DN1YB Wall-mounted R Type MDV-D XX G-R3/N1Y Indoor units lineup Indoor units lineup High Static Pressure Duct MDV-D XX Z/N1-F3B Floor standing MDV-D XX Z/N1-F4(F5) Console Fresh Air processing unit MDV-D XX Z/DN1-B MDV-D XX T1/N1-FA 14 types and more than 100 models are available to meet varied customer requirements. 35 36 One Way Cassette Model MDV-D28Q1/N1-C MDV-D36Q1/N1-C Power supply LED Auto Restart Fresh Air Auto Addressing Cleanable Panel Follow Me Anti-Cold Air Function LED Display Super High Air Flow Cooling capacity DISPLAY Heating capacity kW 2.8 3.6 4.5 5.6 kcal/h 2,400 3,100 3,800 4,800 Btu/h 9,500 12,200 15,300 19,100 kW 3.2 4.0 5.0 6.3 kcal/h 2,700 3,400 4,300 5,400 Btu/h 10,900 13,600 17,000 21,500 Compact design, ultra slim body with a minimum thickness of 198mm, especially suitable for narrow ceilings, such as in lobbies and small meeting rooms. Auto swing mechanism guarantees even Power input 53 53 86 86 airflow distribution and a better room temperature balance. Heating 53 53 86 86 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 m3/h 500/450/410 500/450/410 890/800/750 919/850/760 CFM 294/265/241 294/265/241 524/470/441 541/500/412 dB(A) 36/34/30 36/34/30 41/38/35 41/38/35 W Cooling Rated current A Heating Indoor units lineup Indoor units lineup Auto swing MDV-D56Q1/N1-C 1-phase, 220-240V, 50Hz Cooling Only 198mm thick MDV-D45Q1/N1-C Airflow rate(H/M/L) 198mm Sound level Single-flow design suits corner installation UItra Thin Refrigerant Standard built-in drain pump with 750mm pump head. Fresh air, improved air quality Reserved fresh air intake port for high quality air creates a comfortable and healthy environment. 1,200×198×655 1,080×320×460 1,080×320×460 1,380×265×775 1,380×265×775 23/27 23/27 31/38 31/38 1,050×18×470 1,050×18x470 1,420×10×755 1,420×10×755 1,100×40×520 1,100×40×520 1,470×50×805 1,470×50×805 kg 4/6 4/6 9/11 9/11 L(flare) mm Ф6.35 Ф6.35 Ф6.35 Ф9.53 Piping connections G(flare) mm Ф12.7 Ф12.7 Ф12.7 Ф15.9 Drain piping mm ODФ16 ODФ16 ODФ16 ODФ16 mm 750 750 750 750 Standard Controller mm - Wireless remote controller (RM05/BG(T)E-A/E) Notes: Acetic acid 37 kg Gross dim.(WxHxD) Pump head Acetaldehyde mm Gross dim.(WxHxD) Net/gross Special enzyme sterilization and filtering technologies filter bacteria, smog, and pollen. Provide a clean, healthy and natural air supply. EXV 1,200×198×655 Net dim.(WxHxD) Panel Control method 850×235×400 Net/gross 750mm R410A 850×235×400 Net dim.(WxHxD) Body Type Formol NH3 1. Nominal cooling capacities are based on the following conditions: return air temp. : 27°CDB,19°cwb,outdoor temp.:35°CDB, equivalent ref. Piping: 8m(horizontal) 2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB,outdoor temp.: 7°CDB, 6°CWB,equivalent ref. Piping: 8m(horizontal) 3. Sound level is measured at 1m below the unit. 38 Two Way Cassette Model MDV-D22Q2/N1 MDV-D28Q2/N1 Power supply LED Auto Restart Fresh Air Auto Addressing Cleanable Panel Follow Me Anti-Cold Air Function LED Display Super High Air Flow DISPLAY Heating capacity 2.2 2.8 3.6 4.5 5.6 7.1 kcal/h 1,900 2,400 3,100 3,800 4,800 6,100 Btu/h 7,500 9,500 12,200 15,300 19,100 24,200 kW 2.6 3.2 4.0 5.0 6.3 8.0 kcal/h 2,200 2,700 3,400 4,300 5,400 6,800 Btu/h 8,900 10,900 13,600 17,000 21,500 27,300 57 57 60 92 108 154 Optimized airflow duct with low resistance greatly reduces noise, minimum down to 24 dB(A). High airflow for high ceiling application guarantees comfort in large space. It makes every person in the room get even distribution of airflow and temperature. Stylish design and slim body Thanks to the stylish appearance and slim body, the unit suits any room's decor and ambience. At only 300 mm high, the unit requires only a small suspended ceiling space. Installation has no height limitations, which makes overall design features much more flexible. Heating 57 57 60 92 108 154 0.35 0.45 0.45 0.55 0.55 0.75 0.35 0.45 0.45 0.55 0.55 0.75 m3/h 654/530/410 654/530/410 725/591/458 850/670/550 980/800/670 1,200/1,000/770 CFM 385/312/241 385/312/241 427/348/270 500/394/324 577/471/394 706/589/453 dB(A) 33/29/24 36/32/29 36/32/29 39/35/30 39/35/30 44/40/34 A Heating Airflow rate(H/M/L) Sound level Refrigerant Body Panel Piping connections 750mm EXV 1,172×300×592 1,172×300×592 1,172×300×592 1,355×400×675 1,355×400×675 1,355×400×675 1,355×400×675 1,355×400×675 1,355×400×675 34/42.5 34/42.5 34/42.5 36.5/45 36.5/45 36.5/45 1,430×90×680 1,430×90×680 1,430×90×680 1,430×90×680 1,430×90×680 1,430×90×680 1,525×130×765 1,525×130×765 1,525×130×765 1,525×130×765 1,525×130×765 1,525×130×765 kg 10.5/15 10.5/15 10.5/15 10.5/15 10.5/15 10.5/15 L(flare) mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.53 Φ9.53 G(flare) mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.9 Φ15.9 Drain piping mm ID Ф25, OD Ф32 ID Ф25, OD Ф32 ID Ф25, OD Ф32 ID Ф25, OD Ф32 ID Ф25, OD Ф32 ID Ф25, OD Ф32 mm 750 750 750 750 750 750 mm Gross dim.(WxHxD) kg mm Gross dim.(WxHxD) Pump head Standard Controller Flat-type suction grille design greatly simplifies maintenance work. Control method 1,172×300×592 Net/gross Standard built-in drain pump with 750mm pumphead (higher pumphead can be customized). R410A 1,172×300×592 Net dim.(WxHxD) 305mm Type 1,172×300×592 Net dim.(WxHxD) Net/gross 300mm W Cooling Rated current MDV-D71Q2/N1 - Wireless remote controller (RM05/BG(T)-A) Notes: 1. Nominal cooling capacities are based on the following conditions: return air temp. : 27°CDB,19°CWB,outdoor temp.:35°CDB, equivalent ref. Piping: 8m(horizontal) 2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB,outdoor temp.: 7°CDB, 6°CWB,equivalent ref. Piping: 8m(horizontal) 3. Sound level is measured at 1.4m below the unit. 39 40 Indoor units lineup Indoor units lineup High airflow MDV-D56Q2/N1 kW Cooling Quiet operation MDV-D45Q2/N1 1-phase, 220-240V, 50Hz Cooling capacity Power input MDV-D36Q2/N1 Compact Four Way Cassette MDV-D22Q4/N1-A3 Model MDV-D28Q4/N1-A3 Power supply Auto Restart Fresh Air Auto Addressing Cleanable Panel Follow Me Anti-Cold Air Function Built-in Drain Pump LED Display LED DISPLAY Cooling capacity Super High Air Flow kW 2.2 2.8 3.6 4.5 kcal/h 1,900 2,400 3,100 3,800 Btu/h 7,500 9,500 12,200 15,300 kW 2.4 3.2 4.0 5.0 kcal/h 2,000 2,700 3,400 4,300 Btu/h 8,900 10,900 13,600 17,000 51 52 58 58 43 44 50 51 0.175 0.175 0.21 0.21 0.175 0.175 0.21 0.21 m3/h 522/414/313 520/415/320 610/521/409 610/521/409 CFM 307/244/184 306/200/188 359/306/241 359/306/241 dB(A) 35.8/33.4/23.4 35.8/33.4/23.4 41.5/35.6/28.8 41.5/35.6/28.8 Cooling Power input m m 0m 57 Heating Cooling Rated current Extremely compact casing suits any room's decor and requires little space for installation on a low ceiling. Due to the compact body and light weight, all models can be installed without a hoist. A Heating Airflow rate(H/M/L) Sound level Refrigerant Quiet operation, gentle air supply Four-way uniform airflow Panel 360°Airflow outlet 360° air outlet provides strong air flow circulation to cool or heat every corner of a room and evenly distribute temperature. 41 Four air discharge ports provide strong air flow circulation to cool or heat every corner of a room and evenly distribute temperature. High airflow mode can maximize the conditioning effect in rooms that are over 3m high. Lift pump connections EXV 570×260×570 675×285×675 675×285×675 675×285×675 675×285×675 17.5/22 17.5/22 19/23.5 19/23.5 647×50×647 647×50×647 647×50×647 647×50×647 705×113×705 705×113×705 705×113×705 705×113×705 kg 3/5 3/5 3/5 3/5 L(flare) mm Ф6.35 Ф6.35 Ф6.35 Ф6.35 G(flare) mm Ф12.7 Ф12.7 Ф12.7 Ф12.7 Drain piping mm ID Ф20 ODФ25 ID Ф20 ODФ25 ID Ф20 ODФ25 ID Ф20 ODФ25 mm 500 500 500 500 mm Gross dim.(WxHxD) kg mm Gross dim.(WxHxD) Net/gross Piping Control method 570×260×570 Net dim.(WxHxD) 3-D spiral fan blade R410A 570×260×570 Net/gross Diffuser Type 570×260×570 Net dim.(WxHxD) Body Streamline plate ensures quiet operation Advanced 3-D spiral fan design reduces air resistance and operation noise. W Indoor units lineup Indoor units lineup 570m MDV-D45Q4/N1-A3 1-phase, 220-240V, 50Hz Heating capacity Compact design, easy installation and maintenance MDV-D36Q4/N1-A3 Pump head Standard Controller - Wireless remote controller (RM05/BG(T)E-A) 500mm Drain pump with a 500mm pumphead is fitted as standard; maximum 600mm pumphead is available. Notes: 1. Nominal cooling capacities are based on the following conditions: return air temp. : 27°CDB,19°CWB,outdoor temp.:35°CDB, equivalent ref. Piping: 8m(horizontal) 2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB,outdoor temp.: 7°CDB, 6°CWB,equivalent ref. Piping: 8m(horizontal) 3. Sound level is measured at 1.4m below the unit. 42 Four Way Cassette Model MDV-D28Q4/N1-D MDV-D36Q4/N1-D Power supply Fresh Air Auto Addressing Cleanable Panel Anti-Cold Air Function Follow Me Built-in Drain Pump LED LED Display Heating capacity Cooling Power input Heating Cooling Rated current Heating DISPLAY Super High Air Flow Airflow rate(H/M/L) Sound level Four-stage fan speed ■ Streamline plate ensures quiet operation. ■ Advanced 3-D spiral fan design reduces air resistance and operation noise. Gross dim.(WxHxD) Net/gross Net dim.(WxHxD) Panel Gross dim.(WxHxD) connections Four-way uniform air flow By adding digital tube on the display board, Error Codes can be displayed directly for troubleshooting. Four air discharge ports provide strong air flow circulation to cool or heat every corner of a room and evenly distribute temperature. High airflow mode can maximize the conditioning effect in rooms that are over 3m high. 360°Airflow outlet Reserved multi-function ports 360° air outlet provides strong air flow circulation to cool or heat every corner of a room and evenly distribute temperature. Fresh Air Intake 15,300 19,100 24,200 4.0 5.0 6.3 8.0 kcal/h 2,700 3,400 4,300 5,400 6,800 Btu/h 10,900 13,600 17,000 21,500 27,300 80 80 75 75 82 80 80 75 75 82 0.4 0.4 0.4 0.4 0.5 W A 0.4 0.4 0.4 0.4 0.5 m3/h 847/766/640 847/766/640 864/755/658 864/755/658 1,157/955/749 CFM 498/450/376 498/450/376 508/444/387 508/444/387 680/562/440 dB(A) 42/38/35 42/38/35 42/38/35 42/38/35 45/42/39 R410A mm kg mm EXV 840x230x840 840x230x840 840x230x840 840x230x840 840x230x840 955X247X955 955X247X955 955X247X955 955X247X955 955X247X955 24/28 24/28 26/30 26/30 26/30 950x46x950 950x46x950 950x46x950 950x46x950 950x46x950 1,000x60x1,000 6/8 6/8 L(flare) mm Φ6.35 Φ6.35 Φ6.35 Φ9.53 Φ9.53 G(flare) mm Φ12.7 Φ12.7 Φ12.7 Φ15.9 Φ15.9 Drain piping mm IDФ28.5 ODФ32 IDФ28.5 ODФ32 IDФ28.5 ODФ32 IDФ28.5 ODФ32 IDФ28.5 ODФ32 mm 750 750 750 750 750 MDV-D112Q4/N1-D MDV-D140Q4/N1-D Wireless remote controller (R05/BG(T)E-A) - MDV-D80Q4/N1-D MDV-D90Q4/N1-D kW 8.0 9.0 10.0 11.2 14.0 kcal/h 6,800 7,700 8,600 9,600 12,000 Btu/h 27,300 30,700 34,100 38,200 47,800 kW 9.0 10.0 11.0 12.5 15.0 kcal/h 7,700 8,600 9,400 10,700 12,900 Btu/h 30,700 34,100 37,500 42,600 51,200 97 160 160 160 170 97 160 160 160 170 0.5 0.7 0.7 0.7 0.8 0.5 0.7 0.7 0.7 0.8 m3/h 1,236/973/729 1,540/1,300/1,120 1,540/1,300/1,120 1,540/1,300/1,120 1,800/1,500/1,280 CFM 727/572/429 906/765/659 906/765/659 906/765/659 1059/883/753 dB(A) 45/42/39 48/45/43 48/45/43 48/45/43 50/47/44 Power supply Heating capacity Power input Rated current Cooling Heating Cooling Heating A R410A Control method Gross dim.(WxHxD) Gross dim.(WxHxD) mm kg mm EXV 840x230x840 840x300x840 840x300x840 840x300x840 840x300x840 955X247X955 955X317X955 955X317X955 955X317X955 955X317X955 26/30 32/37 32/37 32/37 32/37 950x46x950 950x46x950 950x46x950 950x46x950 950x46x950 1,000x60x1,000 1,000x60x1,000 1,000x60x1,000 1,000x60x1,000 1,000x60x1,000 kg 6/8 6/8 6/8 6/8 6/8 L(flare) mm Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53 G(flare) mm Φ15.9 Φ15.9 Φ15.9 Φ15.9 Φ15.9 Drain piping mm IDФ28.5 ODФ32 IDФ28.5 ODФ32 IDФ28.5 ODФ32 IDФ28.5 ODФ32 IDФ28.5 ODФ32 mm 750 750 750 750 750 Net/gross connections W Type Refrigerant Panel MDV-D100Q4/N1-D 1-phase, 220-240V, 50Hz Cooling capacity Piping 230mm 12,200 3.2 1,000x60x1,000 Net dim.(WxHxD) 750mm 9,500 kW 6/8 Net/gross Ultra-thin machine body (minimum height 230mm) simplifies installation and maintenance. Btu/h Model Body Drain pump can take condenser water up to 750mm, which simplifies installation of the drain piping system. 6,100 1,000x60x1,000 Net dim.(WxHxD) High lift pump 4,800 6/8 Sound level For duct connecting 3,800 1,000x60x1,000 Airflow rate(H/M/L) To another room 7.1 3,100 6/8 Standard Controller Easy troubleshooting 5.6 2,400 1,000x60x1,000 Drain pump pumphead 3-D spiral fan blade 4.5 kcal/h Indoor units lineup Indoor units lineup Piping 3.6 kg Net/gross Diffuser 2.8 Control method Net dim.(WxHxD) Body MDV-D71Q4/N1-D kW Type Refrigerant Quiet operation, gentle air supply MDV-D56Q4/N1-D 1-phase, 220-240V, 50Hz Cooling capacity Auto Restart MDV-D45Q4/N1-D Pump head Standard Controller - Wireless remote controller (RM05/BG(T)E-A) Notes: 1. Nominal cooling capacities are based on the following conditions: return air temp. : 27°CDB,19°CWB,outdoor temp.:35°CDB, equivalent ref. Piping: 8m(horizontal) 2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB,outdoor temp.: 7°CDB, 6°CWB,equivalent ref. Piping: 8m(horizontal) 3. Sound level is measured at 1.4m below the unit. 43 44 Low Static Pressure Duct Model MDV-D18T3/N1-B MDV-D22T3/N1-B MDV-D28T3/N1-B MDV-D36T3/N1-B MDV-D45T3/N1-B MDV-D56T3/N1-B Power Supply Auto Restart Fresh Air Auto Addressing Cleanable Panel Wired Controller Super High Air Flow 1.8 2.2 2.8 kcal/h 1,547 1,891 2,407 3,095 3,869 4,815 Btu/h 6,100 7,500 9,500 12,200 15,300 19,100 kW 2.2 2.6 3.2 4.0 5.0 6.3 kcal/h 1,891 2,235 2,751 3,439 4,299 5,416 Btu/h 7,500 8,900 10,900 13,600 17,000 21,500 W 40 40 40 40 40 56 Rated Current A 0.17 0.17 0.17 0.17 0.17 0.24 Input W 40 40 40 40 40 56 Cooling Capacity Heating Anti-Cold Air Function Follow Me 220~240V-1Ph-50Hz kW Power (Cooling) Power (Heating) Input 0.17 0.17 0.17 0.17 0.24 0.24 446/323/250 446/323/250 527/359/267 527/359/267 767/634/512 767/634/512 cfm 263/190/147 263/190/147 310/211/157 310/211/157 451/373/301 451/373/301 ESP (external static pressure) Pa 5 5 5 5 5 5 Sound Pressure (Hi/Mid/Lo) dB(A) 33/27/21 34/29/21 36/34/30 36/34/30 37/35/31 37/35/31 sound-sensitive places. EXV Control Method Net dimension W×H×D mm 850×190×405 850×190×405 850×190×405 850×190×405 1,030×190×430 1,030×190×430 Packing dimension W×H×D mm 903×277×445 903×277×445 903×277×445 903×277×445 1,084×277×472 1,084×277×472 kg 11.5/14.5 11.5/14.5 11.5/14.5 11.5/14.5 14 /17.5 14/17.5 Liquid (Flare) mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.53 Φ9.53 Gas (Flare) mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.9 Φ15.9 Drain piping mm IDΦ15 ODΦ20 IDΦ15 ODΦ20 IDΦ15 ODΦ20 IDΦ15 ODΦ20 IDΦ15 ODΦ20 IDΦ15 ODΦ20 Net/Gross Weight level of 21dB (A), an excellent choice for hotels and other R410A Type Piping Connections Pump head Standard Controller mm 750 - Wireless remote controller (RM05/BG(T)E-A) Notes: More smooth Smooth airflow airflow with with less less turbulence turbulence Convenient installation Thanks to the multiple-blade fan rotor and the air guide design, airflow is smoother and more comfortable. The EXV is fixed beside the indoor unit. Chamber is included as standard equipment. Compact design 1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal) 2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal) 3.Sound level is measured at 1.4m below the air outlet. * External static pressure is based on high speed indoor air flow. Options Min.5mm 750mm 190mm Ceiling Uniform 190mm in height, compact design for easy locate where space ceiling is limited, The whole body adopts fireproof plastic material, the minimum weight is 11.5kg. 45 ceiling A drain pump with 750mm pumphead is an optional accessory. 46 Indoor units lineup Indoor units lineup provides a minimum noise 5.6 A Refrigerant Utilizes the cross blow fan, 4.5 m3/h Rated Current Indoor air flow (H/M/L) Low sound level 3.6 Concealed Duct Unit (A5 Type) Model Auto Restart Follow Me Fresh Air Capacity Heating Anti-Cold Air Function Built-in Drain Pump Wired Controller Auto Addressing Cleanable Panel Connectable To Duct Super High Air Flow 2.8 3.6 4.5 5.6 kcal/h 1,891 2,407 3,095 3,869 4,815 Btu/h 7,500 9,500 12,200 15,300 19,100 kW 2.6 3.2 4 5 6.3 kcal/h 2,235 2,751 3,439 4,299 5,416 21,500 Btu/h 8,900 10,900 13,600 17,000 W 59 57 61 92 92 Rated Current A 0.28 0.28 0.28 0.5 0.5 Input W 59 57 61 92 92 Rated Current A 0.28 0.28 0.28 0.5 0.5 m3/h 570/530/410/320 570/530/410/320 570/530/410/320 958/850/667/583 958/850/667/583 CFM 335/312/241/188 335/312/241/188 335/312/241/188 563/500/392/343 563/500/392/343 ESP (external static pressure) Pa 10(10~30) 10(10~30) 10(10~30) 10(10~30) 10(10~30) Sound Pressure (Hi/Mid/Lo) dB(A) 36/35/32 37/35/32 39/38/36 41/38.9/36 41/38.9/36 Power (Cooling) Power (Heating) Type R410A Control Method EXV Net dimension W×H×D mm 700x210x450 700x210x450 700x210x450 920X210X570 920X210X570 Packing dimension W×H×D mm 870x285x525 870x285x525 870x285x525 1,135X290X655 1,135X290X655 kg 17.5/20 17.5/20 17.5/20 27/32 27/32 Liquid (Flare) mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.53 Gas (Flare) mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ16 Drain piping mm IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 Piping Connections Standard Controller mm 750 - Wired controller KJR-12B(6 meters connection wire) ‘Hi’ to change the ESP. Only 210mm (22~71 models) or 270mm (80 to 112 models) or 300mm (140 model) in height. Model MDV-D80T2/N1-BA5 The EXV is fixed inside of the indoor unit. Standard filter is housed in an aluminum frame, which is removable from the bottom in the downward direction. Suction chamber is included as standard equipment. Fresh air hole, air inlet/outlet flange are standard for easy duct connection. A rear air inlet is standard and an inlet at the bottom is optional. Both use the same connectable duct. drain pump as standard 750mm Capacity Heating Flexible control and easy maintenance Standard wired remote controller KJR-12B. The electrical control box can be removed 1m away from the unit for easy maintenance access. Customers need to request this service in advance for it is done at MDV CAC factory. Standard functional ports are included such as Remote On/Off Dry contact switch and Alarm signal output (220V). MDV-D112T2/N1-BA5 MDV-D140T2/N1-BA5 kW 7.1 8 9 11.2 14 kcal/h 6,105 6,879 7,739 9,630 12,037 Btu/h 24,200 27,300 30,700 38,200 47,800 kW 8 9 10 12.5 15.5 kcal/h 6,879 7,739 8,598 10,748 13,327 52,900 Btu/h 27,300 30,700 34,100 42,600 Input W 125 198 200 313 274 Rated Current A 0.7 1 1 1.8 1.55 Input W 125 198 200 313 274 Rated Current A 0.7 1 1 1.8 1.55 m3/h 1,207/1,050/905/821 1,400/1,226/1,018/861 1,400/1,230/1,019/859 1,750/1,752/1,552/1,389 1,789/1,918/1,539/1,250 CFM 710/618/532/483 917/795/687/608 917/795/687/608 1,214/1,059/921/824 1,258/1,118/967/827 ESP (external static pressure) Pa 10(10~30) 20(10~50) 20(10~50) 40(10~80) 40(10~100) Sound Pressure (Hi/Mid/Lo) dB(A) 42/40/35 45.4/39.8/37 45.4/39.8/37 48.0 /41.9/38 47.7/43.2/39.0 Power (Cooling) Power (Heating) Indoor air flow (H/M/L) Refrigerant ceiling MDV-D90T2/N1-BA5 220~240V-1Ph-50Hz Cooling Air intake from below MDV-D71T2/N1-CA5 Power Supply Convenient installation 47 MDV-D56T2/N1-BA5 Indoor units lineup Indoor units lineup Change the wiring connection from ‘SH’ to Ceiling Air intake from back 2.2 Pump head optional) 210mm or270mm or300mm kW Net/Gross Weight Four speed fan motor (Super high speed is MDV-D45T2/N1-BA5 Input Refrigerant External static pressure MDV-D36T2/N1-DA5 220~240V-1Ph-50Hz Indoor air flow (H/M/L) Min.5mm MDV-D28T2/N1-DA5 Power Supply Cooling Compact size MDV-D22T2/N1-DA5 Type R410A Control Method EXV Net dimension W×H×D mm 1140X210X635 1,140X270X710 1,140X270X710 1,140X270X710 1,200X300X800 Packing dimension W×H×D mm 1,135X290X655 1,355X350X795 1,355X350X795 1,355X350X795 1,385X375X920 kg 31.8/35.8 38/46.5 40/48 40/48 49/58 Liquid (Flare) mm Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53 Gas (Flare) mm Φ15.9 Φ15.9 Φ15.9 Φ15.9 Φ15.9 Drain piping mm IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 Net/Gross Weight Piping Connections Pump head Standard Controller mm 750 - Wired controller KJR-12B(6 meters connection wire) Notes: 1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal) 2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal) 3. Sound level is measured at 1.4m below the air out-let. * External static pressure is based on high speed indoor air flow. * Specifications are subject to change without prior notice for product improvement. 48 High Static Pressure Duct Model MDV-D71T1/N1-B MDV-D80T1/N1-B kW 7.1 8 9 11.2 14 16 kcal/h 6,105 6,879 7,739 9,630 12,037 13,757 Btu/h 24,200 27,300 30,700 38,200 47,800 54,600 kW 8 9 10 12.5 16 18 kcal/h 6,879 7,739 8,598 10,748 13,757 15,477 Power Supply Cooling Capacity Auto Addressing Follow Me Wired Controller MDV-D160T1/N1-B Heating Btu/h 27,300 30,700 34,100 42,600 54,600 61,400 Anti-Cold Air Function Input W 263 263 423 524 627 832 Rated Current A 1.1 1.1 1.8 2.3 2.7 3.6 Input W 263 263 423 524 627 832 Connectable To Duct Power (Cooling) Power (Heating) A 1.1 1.1 1.8 2.3 2.7 3.6 m3/h 1,510/1,399/1,236 1,500/1,396/1,221 1,936/1,721/1,511 2,117/1,950/1,644 2,988/2,670/2,229 3,890/3,200/2,700 CFM 889/823/727 883/822/719 1,139/748/889 1,246/1,147/968 1,758/1,572/1312 2,290/1,883/1,589 Pa 40(30~ 196) 40(30~ 196) 40(30~ 196) 50(30~ 196) 50(30~ 196) 50(30~ 196) dB(A) 48/46/44 48/46/44.5 52/49/47 52/49/47 53/50/48 54/52/50 Rated Current ESP (external static pressure) Flexible duct design Sound Pressure (Hi/Mid/Lo) R410A Type Refrigerant Four speed fan motor (super high speed as an option for models 70-160) External static pressure can be up to 196Pa (models 71 to 160) or 250Pa (models 200 to 560). EXV Control Method Net dimension W×H×D mm 952×420×690 952×420×690 952×420×690 952×420×690 1,200×400×600 1,200×400×600 Packing dimension W×H×D mm 1,102×450×768 1,102×450×768 1,102×450×768 1,102×450×768 1,430×450×768 1,430×450×768 kg 45/50 45/50 46.5/52.4 50.6/56 68/70 70/77.5 Liquid (Flare) mm Φ9.52 Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53 Gas (Flare) mm Φ15.9 Φ15.9 Φ15.9 Φ15.9 Φ15.9 Φ15.9 Drain piping mm IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 Net/Gross Weight Piping Connections Fresh air in take Min. 450mm mm Pump head - Standard Controller 750 Wired controller KJR-10B/DP(T)-E (6m wrie is standard) Indoor units lineup Indoor units lineup 420mm MDV-D140T1/N1-B Cleanable Panel Indoor air flow (H/M/L) the longest distance of air supply is 14m MDV-D112T1/N1-B 220~240V-1Ph-50Hz Fresh Air Auto Restart MDV-D90T1/N1-B Wired controller KJR-12B/DP(T)-E (6m wrie is standard) INDOOR UNIT Air supply The height of air supply is 6.5m Air return INDOOR UNIT The maximum distance for air supply is about 14m at height of 6.5m. With a 420mm (models 71 to 160) thick body, the minimum distance required above the ceiling is 450mm. Greater flexibility with the four-speed fan Model MDV-D200T1/N1-B MDV-D250T1/N1-B Power Supply MDV-D280T1/N1-B MDV-D400T1/N1 MDV-D450T1/N1 MDV-D560T1/N1 220~240V-1Ph-50Hz Cooling Capacity kW 20 25 28 40 45 56 kcal/h 17,197 21,496 24,075 34,394 38,693 48,152 Btu/h 68,200 85,300 95,500 136,500 153,500 191,100 kW 22.5 26 31.5 45 50 63 kcal/h 19,346 22,355 27,084 38,693 42,993 54,171 Exchange the wiring connections for ‘MH’ and ‘Me’ (models 71 to 160). Heating Btu/h 76,800 88,700 107,500 153,500 170,600 214,960 Convenient installation Input W 1516 1516 1516 2700 2700 3400 Rated Current A 6.6 6.6 6.6 12.5 12.5 15.5 Input W 1516 1516 1516 2700 2700 3400 Power (Cooling) The EXV is fixed inside the indoor unit (models 70-160), requires no extra connection. Standard filter is housed in an aluminum frame, which is removable from the bottom in the downward direction. Flange for air in/outlet duct connection is standard. Flexible control and convenient for maintenance Wired remote controller KJR-10B/KJR-12B is as standard, and wireless remote controller R05 is as an option. The display board is connected to the E-box in factory, easier troubleshooting by LED display. Easy access filters both at the rear & bottom Standard functional port such as remote on/off dry contact. Double-skin drainage pan Option: Power (Heating) A 6.6 6.6 12.5 12.5 15.5 m3/h 4,268/3,780/3,200 4,280/3,820/3,200 4,400/3,708/3,200 7468/6047/4989 7468/6047/4989 9506/7897/6550 CFM 2,512/2,225/1,883 2,519/2,248/1,833 2,590/2,182/1,883 4396/3559/2936 4396/3559/2936 5595/4648/3855 Pa 140(50~250) 140(50~250) 160(50~250) 196(50~250) 196(50~250) 196(50~250) dB(A) 59/55/52 59/55/52 59/55/52 61/59/56 61/59/56 63/60/57 Rated Current Indoor air flow (H/M/L) ESP (external static pressure) Sound Pressure (Hi/Mid/Lo) Refrigerant Type R410A EXV Control Method Net dimension W×H×D mm 1356×470×763 1356×470×763 1356×470×763 1970*668*858.5 1970*668*858.5 1970*668*858.5 Packing dimension W×H×D mm 1,509×522×964 1,509×522×964 1,509×522×964 2095*800*964 2095*800*964 2095*800*964 kg 115/129 115/129 115/129 232/245 232/245 232/245 Liquid (Flare) mm Φ9.53×2 Φ9.53×2 Φ9.53×2 Ф12.7*2 Ф12.7*2 Ф12.7*2 Gas (Flare) mm Φ15.9×2 Φ15.9×2 Φ15.9×2 Ф22.2x2 Ф22.2x2 Ф22.2x2 Drain piping mm IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 Net/Gross Weight Piping Connections Pump head mm Standard Controller 750mm 6.6 - 750 Wired controller KJR-12B/DP(T)-E (6m wrie is standard) Notes: 1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal) ceiling Drain pump with 750mm pumphead is optional (models 71 to 160) 49 2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal) Double-skin drainage pan provide double protection for ceilings (models 71 to 160 and models 400 to 560) 3. Sound level is measured at 1.4m below the air out-let. * External static pressure is based on high speed indoor air flow. change without prior notice for product improvement. MDV-D200T1/N1-B * Specifications are subject toModel MDV-D250T1/N1-B MDV-D280T1/N1-B 50 Ceiling & floor MDV-D36DL/N1-C MDV-D45DL/N1-C kW 3.6 4.5 5.6 7.1 8 kcal/h 3,100 3,800 4,800 6,100 6,800 Btu/h 12,200 15,300 19,100 24,200 27,300 kW 4 5 6.3 8 9 kcal/h 3,400 4300 5,400 6,800 7,700 Btu/h 13,600 17,000 21,500 27,300 30,700 49 120 122 125 130 49 120 122 125 130 0.55 0.55 0.55 0.57 0.6 0.55 0.55 0.55 0.57 0.6 m3/h 650/570/500 800/600/500 800/600/500 800/600/500 1,200/900/700 CFM 383/335/294 471/353/294 471/353/294 471/353/294 706/530/412 dB(A) 40/38/36 43/41/38 43/41/38 43/41/38 45/43/40 Model Power supply Cooling capacity Fresh Air Auto Restart Heating capacity Auto Addressing Cleanable Panel Anti-Cold Air Function Follow Me Power input Rated current Built-in Drain Pump LED LED Display DISPLAY Cooling Heating Cooling Heating Airflow rate(H/M/L) Sound level Panel with LED display Refrigerant The front panel and display panel have different colors for choose: white and brown for big panel, blue and brown for small panel. Other colors are available if required. Convenient installation MDV-D56DL/N1-C MDV-D71DL/N1-C MDV-D80DL/N1-C 1-phase, 220-240V, 50Hz W A Type R410A Control method EXV mm 990x660x206 990x660x206 990x660x206 990x660x206 1,280x660x206 Packing dimension(W×H×D) mm 1,089x744x296 1,089x744x296 1,089x744x296 1,089x744x296 1,379x744x296 Net weight kg 26 28 28 28 34.5 Gross weight kg 32 34 34 34 41 L(flare) mm Φ6.35 Φ6.35 Φ9.53 Φ9.53 Φ9.53 G(flare) mm Φ12.7 Φ12.7 Φ15.9 Φ15.9 Φ15.9 Drain piping mm OD Ф16 OD Ф16 OD Ф16 OD Ф16 ODФ16 Piping The unit even can be easily installed at the connections corner of a narrow ceilings. Standard Controller Wireless remote controller (RM05/BG(T)E-A) - It is especially useful when central installation is impossible due to features such as lights. The unit can be installed either horizontally on the ceiling or vertically against the wall. Power supply Drop ceiling kW Heating capacity Power input 198mm Rated current Air Outlet The slim and sleek design starting at just 30kg enables quick, easy and neat installation. Low noise operations; minimum 36 dB(A) Auto swing and wide angle air flow Auto Swing & Wide-angle Airflow 1.Auto horizontal and auto vertical swing functions for more even and comfortable airflow. 2.Three air flow speeds: low, medium and high; double air guides. 3.Adopt electronic expansion valve, ensure precise flow control, lower modulation noise when EXV operating. 4.Smoother airflow and less turbulence due to the multi-blade fan and the air guide design. MDV-D112DL/N1-C MDV-D140DL/N1-C MDV-D160DL/N1-C 1-phase, 220-240V, 50Hz Cooling capacity Quiet and comfortable environment >20 MDV-D90DL/N1-C Model Cooling Heating Cooling Heating Airflow rate(H/M/L) Sound level Refrigerant 9 11.2 14 16 kcal/h 7,700 9,600 12,000 13,757 Btu/h 30,700 38,200 47,800 54,600 kW 10 12.5 15.5 18 kcal/h 8,600 11,000 13,000 15,477 Btu/h 34,100 42,600 52,900 61,400 130 182 182 300 130 182 182 300 0.6 0.83 0.83 1.41 W A 0.6 0.83 0.83 1.41 m /h 1,200/900/700 1,980/1,860/1,730 1,980/1,860/1,730 1,980/1,860/1,730 CFM 706/530/412 1,165/1,095/1,018 1,165/1,095/1,018 1,165/1,095/1,018 dB(A) 45/43/40 47/45/42 47/45/42 47/45/42 3 Type R410A Control method EXV Net dimension(W×H×D) mm 1,280x660x206 1,670x680x244 1,670x680x244 1,670x680x285 Packing dimension(W×H×D) mm 1,379x744x296 1,764x760x329 1,764x760x329 1,775x760x372 kg 34.5 54 54 57.5 59 59 63.5 Φ9.53 Φ9.53 Φ9.53 Net weight kg 41 L(flare) mm Φ9.53 G(flare) mm Φ15.9 Φ15.9 Φ15.9 Φ15.9 mm ODФ16 ODФ16 ODФ16 ODФ16 Gross weight Piping connections Drain piping Standard Controller - Wireless remote controller (RM05/BG(T)E-A) Notes: 1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal) 2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal) 3. Floor standing :Sound level is measured 1m from air-outlet in horizontal distance, 1m above the floor in vertical distance. Ceiling mounted:Sound level is measured 1m from air-outlet in horizontal distance,1m from air-outlet in vertical distance. * Specifications are subject to change without prior notice for product improvement. 51 52 Indoor units lineup Indoor units lineup Net dimension(W×H×D) S type panel Wall mounted Auto Restart Model S type panel C type panel Anti-Cold Air Function R type panel Heating capacity Follow Me NEW Cooling Power input panel design LED Display LED kW 2.2 2.8 3.6 4.5 5.6 kcal/h 1,900 2,400 3,100 3,900 4,800 Btu/h 7,500 9,500 12,200 15,300 19,100 kW 2.4 3.2 4 5 6.3 kcal/h 2,100 2,700 3,400 4,300 5,400 Btu/h 8,200 10,900 13,600 17,000 21,500 28 28 28 45 45 28 28 28 45 45 0.14 0.14 0.14 0.2 0.2 1-phase, 220-240V, 50Hz Cooling capacity Cleanable Panel Heating Cooling Rated current DISPLAY Heating Airflow rate(H/M/L) Sound level Panel with LED display MDV-D56G/N1-S MDV-D28G/N1-S Power supply Auto Addressing MDV-D36G/N1-S MDV-D45G/N1-S MDV-D22G/N1-S Refrigerant W A 0.14 0.14 0.14 0.2 0.2 m3/h 525/480/430 525/480/430 590/520/480 860/755/630 925/860/755 CFM 309/283/253 309/283/253 309/283/253 506/444/371 544/506/444 dB(A) 35/32/29 35/32/29 35/32/29 40/38/34 40/38/34 915 ×290×230 1,072×315×230 1,072×315×230 1,020×390×315 1,180×415×315 1,180×415×315 15.1 Type R410A Control method EXV Net weight kg 13 13 13 15.1 Convenient installation Gross weight kg 16.5 16.5 16.5 18.8 18.8 L(flare) mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 G(flare) mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.9 Drain piping mm ODФ16.5 ODФ16.5 ODФ16.5 ODФ16.5 ODФ16.5 Packing dimension(W×H×D) Piping connections Multi-refrigerant outlet pipe method: left\right\rear, more flexible for installation. The EXV is built-in the indoor unit, compact size, Longer the connection pipe;gas pipe: 468mm; liquid pipe: 550mm, more flexible for installation Adopts new type fixing plate, is easy to install and stable. Standard Controller Easy maintenance The Auto Swing Louver function ensures that the air direction corresponds to the mode selected. The front panel can be removed for easy maintenance access. Open panel 1 Step Swing Heating capacity Power input Rated current 2 Cooling Heating Cooling Heating Airflow rate(H/M/L) 3 4 Sound level The mechanical expansion valve offers 2,000-stage element positions to ensure precise flow control and less modulation noise when the EXV is operating for a quiet and comfortable environment. Three air flow speeds: low, medium and high; double air guides. Smoother airflow and less turbulence is ensured by the multi-blade fan and the air guide design. 1,020×390×315 915×290×230 1,020×390×315 Wireless remote controller (RM05/BG(T)E-A) - MDV-D36G/DN1-S MDV-D45G/DN1-S MDV-D56G/DN1-S MDV-D22G/DN1-S MDV-D28G/DN1-S kW 2.2 2.8 3.6 4.5 5.6 kcal/h 1,900 2,400 3,100 3,900 4,800 1-phase, 220-240V, 50Hz Btu/h 7,500 9,500 12,200 15,300 19,100 kW 2.4+0.75 3.2+0.75 4+0.75 5+0.9 6.3+0.9 kcal/h 2,100+600 2,700+600 3,400+600 4,300+800 5,400+800 Btu/h 8,200+2,600 10,900+2,600 13,600+2,600 17,000+3,100 21,500+3,100 28 28 28 45 45 28 28 28 45 45 0.14 0.14 0.14 0.2 0.2 W A 0.14+3.38 0.14+3.38 0.14+3.38 0.20+4.05 0.20+4.05 3 m /h 525/480/430 525/480/430 590/520/480 860/755/630 925/860/755 CFM 309/283/253 309/283/253 347/306/283 506/444/371 544/506/444 dB(A) 35/32/29 35/32/29 35/32/29 40/38/34 40/38/34 R410A Type Refrigerant Optimal comfort through better flow control and quiet operations 915×290×230 Power supply Right Cooling capacity Auto swing louver mm Model Rear Left mm EXV Control method Net dimension(W×H×D) mm 915×290×230 915×290×230 915 ×290×230 1,072×315×230 1,072×315×230 Packing dimension(W×H×D) mm 1,020×390×315 1,020×390×315 1,020×390×315 1,180×415×315 1,180×415×315 Net weight kg 13 13 13 15.1 15.1 Gross weight kg 16.5 16.5 16.5 18.8 18.8 L(flare) mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 G(flare) mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.9 Drain piping mm ODФ16.5 ODФ16.5 ODФ16.5 ODФ16.5 ODФ16.5 Piping connections Standard Controller Indoor units lineup Indoor units lineup The front panel and display panel have different colors for choose: white and brown for big panel, blue and brown for small panel. Net dimension(W×H×D) - Wireless remote controller (RM05/BG(T)E-A) Notes: 1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal) 2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal) 3. Sound level is measured 1m below the air outlet horizontally and vertically. * Specifications are subject to change without prior notice for product improvement. 53 54 C type panel R type panel Model MDV-D22G/N1YB MDV-D28G/N1YB Power supply Cooling capacity Heating capacity Cooling Power input Heating Cooling Rated current Heating Airflow rate(H/M/L) Sound level Net dimension(W×H×D) Packing dimension(W×H×D) Net weight Power supply 5.6 4.5 3.6 2.8 1,900 2,400 3,100 3,900 4,800 Btu/h 7,500 9,500 12,300 15,400 19,100 kW 2.4 3.2 4 5 6.3 kcal/h 2,200 2,700 3,400 4,300 5,400 Btu/h 8,900 10,900 13,600 17,000 21,500 W A 28 28 45 45 28 28 45 45 28 28 0.14 0.14 0.14 0.2 0.2 0.14 0.14 0.14 0.2 0.2 3 m /h 525/480/430 525/480/430 525/480/430 860/755/630 925/860/755 CFM 309/283/253 309/283/253 309/283/253 506/444/371 544/506/444 35/32/29 35/32/29 35/32/29 Type R410A Control method EXV mm mm kg Gross weight 2.2 kg 915×290×210 1,020×385×300 12 16 915×290×210 1,020×385×300 12 40/38/34 40/38/34 Airflow rate(H/M/L) Sound level 6,800 7,700 Btu/h 24,200 27,300 30,700 kW 8 9 10 kcal/h 6,800 7,700 8,600 Btu/h 27,300 30,700 34,100 79 95 95 79 95 95 0.33 0.39 0.39 W A 9 0.33 0.39 0.39 m3/h 1,190/880/680 1,320/840/640 1,320/840/640 CFM 700/518/400 776/494/376 776/494/376 dB(A) 45/42/39 47/43/41 47/43/41 Type R410A Control method EXV mm 1,250x325x230 1,250x325x230 1,250x325x230 1,020×385×300 Packing dimension(W×H×D) mm 1,345x335x430 1,345x335x430 1,345x335x430 12 16 16 Net weight kg 19.9 19.9 19.9 19 Gross weight kg 25 25 25 L(flare) mm Φ9.53 Φ9.53 Φ9.53 G(flare) mm Φ15.9 Φ15.9 Φ15.9 Drain piping mm OD Ф16.5 OD Ф16.5 OD Ф16.5 19 Φ6.35 Φ6.35 Φ6.35 Φ9.53 Φ12.7 Φ12.7 Φ12.7 Φ15.9 ODФ16.5 ODФ16.5 ODФ16.5 Piping connections Standard Controller Wireless remote controller (RM05/BG(T)E-A) - Indoor units lineup Indoor units lineup Net dimension(W×H×D) Φ12.7 ODФ16.5 Heating 6,100 1,165×395×285 Φ6.35 ODФ16.5 Cooling 8 kcal/h 1,070×315×210 mm - Heating 7.1 1,165×395×285 mm mm Cooling kW 1,070×315×210 G(flare) Drain piping Heating capacity Rated current MDV-D90G-R3/N1Y 915×290×210 L(flare) Standard Controller Cooling capacity Power input MDV-D80G-R3/N1Y 1-phase, 220-240V, 50Hz Refrigerant 16 16 MDV-D71G-R3/N1Y Model MDV-D56G/N1YB kcal/h dB(A) Refrigerant connections MDV-D45G/N1YB 1-phase, 220-240V, 50Hz kW Piping MDV-D36G/N1YB Wireless remote controller (RM05/BG(T)E-A) Notes: Model MDV-D22G/DN1YB MDV-D28G/DN1YB Power supply Heating capacity Rated current MDV-D45G/DN1YB MDV-D56G/DN1YB Cooling Heating Cooling Heating Airflow rate(H/M/L) Sound level kW 2.2 2.8 kcal/h 1,900 2,400 3,100 3,900 4,800 Btu/h 7,500 9,500 12,300 15,400 19,100 kW 2.4+0.75 3.2+0.75 4+0.75 5+0.9 6.3+0.9 2,200+600 2,700+600 3,400+600 4,300+800 5,400+800 Btu/h 8,900+2,500 10,900+2,500 13,600+2,500 17,000+3,100 21,500+3,100 28 28 28 45 45 28 28 28 45 45 0.14 0.14 0.14 0.2 0.2 A 0.14+3.38 0.14+3.38 0.14+3.38 0.2+4.05 0.2+4.25 m3/h 525/480/430 525/480/430 525/480/430 860/755/630 925/860/755 CFM 309/283/253 309/283/253 309/283/253 506/444/371 544/506/444 dB(A) 35/32/29 35/32/29 35/32/29 40/38/34 40/38/34 mm 915×290×210 915×290×210 915×290×210 1,070×315×210 1,070×315×210 Packing dimension(W×H×D) mm 1,020×385×300 1,020×385×300 1,020×385×300 1,165×395×285 1,165×395×285 Net weight kg 12 12 12 16 16 Gross weight kg 16 16 16 19 19 Φ9.53 connections L(flare) mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 G(flare) mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.9 Drain piping mm ODФ16.5 ODФ16.5 ODФ16.5 ODФ16.5 ODФ16.5 Standard Controller * Specifications are subject to change without prior notice for product improvement. EXV Control method Net dimension(W×H×D) Piping 2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal) R410A Type Refrigerant 5.6 4.5 3.6 kcal/h W 1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal) 3. Sound level is measured 1m below the air outlet horizontally and vertically. 1-phase, 220-240V, 50Hz Cooling capacity Power input MDV-D36G/DN1YB - Wireless remote controller (RM05/BG(T)E-A) Notes: 1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal) 2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal) 3. Sound level is measured 1m below the air outlet horizontally and vertically. * Specifications are subject to change without prior notice for product improvement. 55 56 Floor standing MDV-D22Z/N1-F3B MDV-D28Z/N1-F3B MDV-D36Z/N1-F3B MDV-D45Z/N1-F3B MDV-D56Z/N1-F3B MDV-D71Z/N1-F3B MDV-D80Z/N1-F3B Model MDV-D22Z/N1-F4 MDV-D28Z/N1-F4 MDV-D36Z/N1-F4 MDV-D45Z/N1-F4 MDV-D56Z/N1-F4 MDV-D71Z/N1-F4 MDV-D80Z/N1-F4 MDV-D22Z/N1-F5 MDV-D28Z/N1-F5 MDV-D36Z/N1-F5 MDV-D45Z/N1-F5 MDV-D56Z/N1-F5 MDV-D71Z/N1-F5 MDV-D80Z/N1-F5 Auto Restart Cleanable Panel Anti-Cold Air Function Auto Addressing Follow Me LED LED Display 1-phase, 220-240V, 50Hz Power supply Cooling capacity Heating capacity DISPLAY Power input Rated current Cooling Heating Cooling Heating Airflow rate(H/M/L) Sound level(Hi/Mid/Lo) kW 2.2 2.8 3.6 4.5 5.6 7.1 8 kcal/h 1,900 2,400 3,100 3,900 4,800 6,100 6,900 Btu/h 7,500 9,500 12,200 15,300 19,100 242,00 27,300 kW 2.4 3.2 4 5 6.3 8 9 kcal/h 2,100 2,700 3,400 4,300 5,400 6,900 7,700 Btu/h 8,200 10,900 13,600 17,000 21,500 27,300 30,700 40 46 40 49 88 130 130 40 46 35 49 88 130 130 0.19 0.2 0.19 0.22 0.38 0.57 0.57 W A 0.19 0.2 0.15 0.22 0.38 0.57 0.57 3 m /h 530/456/400 569/485/421 624/522/375 660/542/440 1,150/970/830 1,380/1,100/870 1,332/1,212/1,023 CFM 312/268/235 335/285/248 367/307/221 388/319/259 677/571/489 812/647/512 784/713/602 36/33/29 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33 44/39/33 36/33/29 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33 44/39/33 36/33/29 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33 44/39/33 F3B F4 dB(A) F5 Refrigerant Easy installation Type R410A Control method EXV F3B Easy maintenance (W×H×D) Packing dimension (W×H×D) Net/Gross weight F4 mm F5 F3B F4 mm F5 F3B F4 kg F5 Filter is provided as a standard accessory. It can be removed and cleaned easily thanks to MDV’s sophisticated design and the product's removable blades. The streamlined appearance harmonizes the unit with a given room's interior decor. All metal parts are made of commercial grade galvanized steel for maximum protection against corrosion. Piping connections 840×212×545 1,036×212×545 1,036×212×545 1,336×212×545 1,336×212×545 1,336×212×545 1,000×220×625 1,000×220×625 1,200×220×625 1,200×220×625 1,500×220×625 1,500×220×625 1,500×220×625 1,000×220×625 1,000×220×625 1,200×220×625 1,200×220×625 1,500×220×625 1,500×220×625 1,500×220×625 925×305×639 925×305×639 1,125×305×639 1,125×305×639 1,425×305×639 1,425×305×639 1,425×305×639 1,089×312×722 1,089×312×722 1,289×312×722 1,289×312×722 1,589×312×722 1,589×312×722 1,589×312×722 1,182×312×722 1,182×312×722 1,382×312×722 1,382×312×722 1,682×312×722 1,682×312×722 1,682×312×722 26/29.5 26/29.5 29.5/34 29.5/34 36/40 36/40 36/40 30/35 30/35 37/43 37/43 44/50 44/50 44/50 30/38 30/38 37/46 37/46 44/53 44/53 44/53 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.53 Φ9.53 Φ9.53 L(flare) mm G(flare) mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.9 Φ15.9 Φ15.9 Drain piping mm ODФ16 ODФ16 ODФ16 ODФ16 ODФ16 ODФ16 ODФ16 Standard Controller Wireless remote controller (RM05/BG(T)E-A) Notes: 1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal) 2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal) 3. Sound level is measured 1m from the air out-let in horizontal distance and 1m above the floor in vertical distance. * Specifications are subject to change without prior notice for product improvement. Saves installation space Concealed floor standing type F3 series concealed type 57 The body is concealed in the skirting board to improve aesthetics. The body is just 212mm deep, and can be installed at the room's perimeter. Special installation methods eliminate noise in the room area. Air intake from front(F4 series) Air intake from below(F5 series) 58 Indoor units lineup Indoor units lineup Floor standing types can be hung on the wall or installed on the floor. The floor type of unit can make cleaning and maintenance much easier. Running the piping from the rear allows the unit to be hung on walls. Cleaning under the unit, where dust tends to accumulate, is considerably easier. Net dimension 840×212×545 Console High efficiency filter Auto Restart Cleanable Panel Auto Addressing Anti-Cold Air Function Follow Me LED LED Display Built in Formaldehyde nemesis filter Active-carbon and biological anti-virus filter are optional. Two air outlets and four air inlets Low-noise design DISPLAY Four directions of air inlet; two options of air outlet: Up and Down; or Up only. Five-speed indoor unit; low noise; low power consumption. Air Outlet Compact size and stylish Indoor units lineup Indoor units lineup Air Inlet The elegant and thin unit body complements the existing decor and saves space. The EXV is installed inside of the indoor unit for added compactness. Low noise operation, lowest to 26dB(A) Bottom, top, and right/left side, for better ventilation. Flexible installation Can be installed on the floor or lower wall Model MDV-D28Z/DN1-B kW 2.2 2.8 3.6 4.5 kcal/h 1,900 2,400 3,100 3,900 Btu/h 7,500 9,500 12,200 15,300 kW 2.6 3.2 4.0 5.0 kcal/h 2,200 2,700 3,400 4,300 Btu/h 8,900 10,900 13,600 17,000 20 25 25 45 20 25 25 45 0.09 0.11 0.11 0.2 Power supply As a floor standing type, it can be semi or fully accessed without losing capacity. Cooling capacity High Comfort Heating capacity Flexible air blow: vertical auto swing and wide angle louvers ensure that warm air reaches every corner of the room and increases the air flow coverage. Indoor unit adopts DC motor with five fan speeds to meet different requirements. Applies the Fujikoki mechanical expansion valve which offers 2,000-stage element positions to ensure precise flow control and lower modulation noise when the EXV is operating. Power input Rated current Cooling Heating Cooling Heating Airflow rate(H/M/L) Sound level Powerful mode can be selected for rapid cooling or heating COOLING MODE MDV-D22Z/DN1-B HEATING MODE MDV-D45Z/DN1-B 1-phase, 220-240V, 50Hz W A 0.09 0.11 0.11 0.2 3 m /h 430/345/229 510/430/229 510/430/229 660/512/400 CFM 253/203/135 300/253/135 300/253/135 388/300/235 dB(A) 38/32/26 39/33/27 39/33/27 42/39/36 R410A Type Refrigerant MDV-D36Z/DN1-B EXV Control method Net dimension(W×H×D) mm 700×600×210 700×600×210 700×600×210 700×600×210 Packing dimension(W×H×D) mm 810×710×305 810×710×305 810×710×305 810×710×305 Net weight kg 14 15 15 15 Gross weight kg 19 20 20 20 L(flare) mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 G(flare) mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 OD Ф16 OD Ф16 OD Ф16 Piping connections Drain piping - OD Ф16 Standard Controller Wireless remote controller (RM05/BG(T)E-A) Notes: 1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal) Quick cooling To maintain temperature Anti-cold air Normal operation 2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal) 3. Sound level is measured 1m from the air out-let in horizontal distance and 1m above the floor in vertical distance. * Specifications are subject to change without prior notice for product improvement. 59 60 Fresh Air Processing unit Heating Power (Cooling) Power (Heating) The height of air supply is 6.5m 14 20 25 28 kcal/h 10,766 12,057 17,225 21,531 24,115 Btu/h 42,600 47,800 68,200 85,300 95,500 kW 10.5 12 18 20 22 kcal/h 9,043 10,335 15,502 17,225 18,947 41,000 61,400 68,200 75,000 461 461 1063 1,063 1063 Rated Current A 2.3 2.3 5.3 5.3 5.3 Input W 461 461 1063 1,063 1,063 Rated Current 2.3 5.3 5.3 5.3 1,700/1,350/1,050 3,150/2,650/2,300 3,300/2,850/2,500 3,300/2,850/2,500 CFM 1,000/795/618 1,000/795/618 1,854/1,560/1,354 1,942/1,677/1,471 1,942/1,677/1,471 Pa 50(30~220) 50(30~220) 140(50~260) 140(50~260) 140(50~260) dB(A) 54/52/50 54/52/50 54/53/51 55/54/52 55/54/52 R410A EXV Control Method Net dimension W×H×D mm 1,200×400×600 1,200×400×600 1,425×500×928 1,425×500×928 1,425×500×928 Packing dimension W×H×D mm 1,436×450×768 1,436×450×768 1,509×550×990 1,509×550×990 1,509×550×990 kg 69.5/76 69.5/76 115/125 115/125 115/125 Liquid (Flare) mm Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53 Gas (Flare) mm Φ15.9 Φ15.9 Φ15.9 Φ15.9 Φ15.9 Drain piping mm OD Ф25 OD Ф25 OD Ф32 OD Ф32 OD Ф32 - - - Piping Connections Standard Controller Air return 2.3 1,700/1,350/1,050 Type Pump head Both fresh air filtration and heating/cooling can be achieved in a single system. Indoor units and fresh air processing unit can be connected to the same refrigerant system, increase design flexibility and greatly reduce total system costs. A m3/h mm - 750 Indoor units lineup Indoor units lineup Air supply 12.5 35,800 Net/Gross Weight 100% Fresh air processing unit INDOOR UNIT kW W Sound Pressure (Hi/Mid/Lo) Fresh air is imported, provides a healthy and comfortable living environment. MDV-D280T1/N1-FA Btu/h ESP (external static pressure) Healthy and comfortable MDV-D250T1/N1-FA Input Air flow (H/M/L) Refrigerant MDV-D200T1/N1-FA 1-phase, 220-240V, 50Hz Capacity Fresh air in take MDV-D140T1/N1-FA Power Supply Cooling the longest distance of air supply is 14m MDV-D125T1/N1-FA Model Wired controller KJR-12B/DP(T)-E (6m wrie is standard) Notes: 1 .Nominal cooling capacities are based on the following conditions: outdoor air temp.: 33ºC DB, 24ºC WB, equivalent ref. piping: 8m (horizontal) 2. Nominal heating capacities are based on the following conditions: outdoor air temp.: 0°CDB, -1°CWB, equivalent ref. Piping: 8m (horizontal) 3. Sound level is measured 1.4m from the air out-let. * external static pressure are based on high speed indoor air flow. * Specifications are subject to change without prior notice for product improvement. Connection Conditions: The following restrictions must be observed in order to maintain the indoor units connected to the same system. * * * High external static pressure When outdoor-air processing units are connected, the total connection capacity must be within 50% to 100% of that of the outdoor units. When outdoor-air processing units and standard indoor units are connected, the total connection capacity of the outdoor-air processing units must not exceed 30% of that of the outdoor units. Outdoor-air processing units can be used without indoor units. External static pressure can be up to 220Pa(models 125 to 140) and 260Pa(models 200 to 280) for more flexible duct applications. The maximum distance of air supply is about 14m and the maximum height of air supply is about 6.5m. Innovative air supply technology for excellent room temperature control Layout Example: Outdoor Units Indoor Unit Indoor Unit Outdoor Air processing unit Air-conditioning 61 Fresh air supply 62 Control Systems Network Control MDV Router Centralized Control Individual control Indoor Centralized Controller (Touch-style Key) X,Y,E MDV Remote Service Centre User’s Monitoring System Remote controller CCM30 Connectable to various sized Gateway Wired controller KJR-10B KJR-12B KJR-90A KJR-29B KJR-86C KJR-120A RM02 RM05 R05 R06 R51 R71 Weekly Schedule Centralized Controller X,Y,E IMM Software M-INTERFACE Gateway Card-key Interface Indoor Centralized Controller MD-LonGW64 Control system Control system Lonworks BMS Accessories MD-CCM09 MD-NIM05 X,Y,E Card-key MD-CCM03 Remote Alarm Controller BACnet BMS MD-CCM08 Web monitoring system Outdoor Centralized Controller F1,F2,E K1,K2,E KJR-32B MD-CCM02 Modbus BMS 63 Modbus gateway Note: The wires in the diagram show the signal flows only, while not represent the actual connecting ways. Outdoor units 64 Comparison of Controllers Item Model name MAX. controllable IDU Wireless Remote Controller Remote RM05/RM02 R51/R71 removable Wired Controller R05/R06 KJR-10B /KJR-120A KJR-90A /KJR-86C 1 1 Centralized KJR-29B CCM30 MD-CCM09 /KJR-12B /MD-CCM03 /KJRF-180A 1 64 64/16 KJR-90B 16 On/Off RM02 Operation mode setting Room temp. setting R06 Portable device Vertical swing R51 R71 Simplified user interface The wireless remote controller is a portable control device that enables users to control the A/C anywhere within a distance of 11m. Horizontal swing function R05 Functions Fan speed setting A/C control RM05 Air direction Users can synchronize the air conditioners’ parameters with the display panel on the wireless remote controller to precisely control a room's environment. Economic mode Group setting Key lock Mode lock Temp 1 Transmitting display 2 Running mode 4 Remote signal receiving ON 26°C shortcut setting Control system Current time Display Error code Period Week On/Off per day 4 On/Off per week 28 On/Off timer The background light allows users to operate the device in a dark room. The device lights up when a button is pressed, and turns off when a given operation is completed. Time 6 Lock 7 Time ON/OFF 9 Fan speed AUTO Emergent stop Emergent start Setting addresses Address setting Auto Mode DRY Mode FAN Mode Lock Built-in timer The built-in daily timer offers the convenience of automatically starting and stopping the system at set times. FOLLOW ME Control 5 Background light RC prohibition Address Timer 8 ON/OFF Control system Economic operation Backlight OFF 3 24°C ON 0 3 6 9 12 15 HEAT Mode COOL Mode Economic operation Addressing setting OFF 18 21 Time The indoor unit is set to work in automode from 8:00 to 20:00 Besides the machine’s auto addressing function, users can set the indoor unit’s address on the wireless remote controller. BMS access Control via internet Air filter cleaning reminding 10℃ heat function - Specifications Model : Available controller functions : Not available controller functions 65 Dimensions (H×W×D)(mm) Power (V) RM02 RM05 R05 R06 R51 R71 150×60×15 150×65×20 150×65×20 100×55×20 140×60×15 125×42×27 1.5V(LR03/AAA)×2 66 Wired Controller Wired Controller KJR-10B KJR-12B KJR-29B KJR-90A Functions KJR-86C KJR-120A Functions Features Follow me • Basic functions are the same as KJR-10B With the FOLLOW ME function, the wired controller • Small and easy to install can detect the air temperature at the user’s altitude Sensor part • Suitable for all types of indoor units instead that of the ceiling or floor. This helps making the room environment comfortable and • Can be stored in a mounting cabinet the Built-in timer temperature accurate. FOLLOW ME Button The built-in daily timer offers the convenience of Air filter cleaning reminding icon Air filter cleaning reminding KJR-29B provides a signal The air filter cleaning reminder receiver for wireless remote functionprovided by KJR-10B/KJR controller. The signal is then -29B/KJR-120A reminds usersvia sent to the indoor unit. the wired controller when the filter Control system Control system Remote signal receiving Remote signal receiving function KJR-90A automatically starting and stopping the system at set times. *The follow me function is available for KJR-12B/KJR-29B model. Mode Setting Mode-button hidden controller :Press the temperature buttons "▲" and "▼" simultaneously for 3 seconds to select the 26°C Shortcut setting operation mode: COOL and HEAT. The design is suitable for Combination key hotels, hospitals, schools and other similar types of buildings. KJR-86C of an indoor unit needs cleaning. KJR-29B (Touch-sytle key) 26oC operation shortcut key 26oC shortcut setting Locking wired controller The optimum temperature for The locking function can be used to balancing energy-saving and prevent other people from using the comfort is 26 C. controller. Easy connection Display panel Selecting mode 10oC heat function V4 plus R controller: Under 10 C heat operating mode, when the room temperature is lower than 10 C, the wired controller can open the heat mode automatically. When the room KJR-10B Wired controller 10oC heat function temperature is higher than 15 C, then it will stop heating. This The wired controller conveniently connects to the is designed to ensure a comfortable and consistent indoor unit’s display panel via a connecting wire. environment. Indoor main board KJR-120A Specifications Specifications Model Dimensions (H×W×D)(mm) Power (V) 67 10B 12B 120×120×15 120×120×15 DC 5V 29B 120×120×20 Model Dimensions (H×W×D)(mm) Power (V) 90A 90×86×13 86C 86×86×18 120A 120×120×15 DC 5V 68 Centralized Controller Indoor Centralized Controller MD-CCM03 Swing With the PC or gateway communication HEAT Mode Key Lock Wireless Remote Controller Lock CCM30 Functions Centralized control P,Q,E P,Q,E X,Y,E Auto Mode COOL Mode HEAT Mode Fan Mode Swing Key Lock MD-CCM09 DRY Mode Sending query order Cooling Lock Heating Lock Wireless Remote With the PC or gateway communication Controller Lock Functions Weekly schedule MD-CCM09 can include up to 64 indoor units in the weekly schedule. Users can set up to 4 periods per 8:00 16:00 Sun 28°C 22°C 23:59 24°C Mon 26°C 22°C 17°C 23°C day, and select the desired running mode and room Tue 26°C 22°C 17°C 23°C temperature. The operating object can be a single Wed 26°C 22°C 17°C 23°C Thu 26°C 22°C 26°C Fri 26°C 22°C 26°C Sat 28°C off 24°C indoor unit or all the indoor units. P,Q,E X,Y,E Locking Remote Controller Locking Keyboard X,Y,E Air filter cleaning reminding function The centralized controller displays indoor units' working status and error codes so users can easily identify faults via checking the error codes table in the user's manual before contacting a service engineer. The air filter cleaning reminder function is only available on the touch-key central controller CCM30. The "FL" icon indicates that the air filter in a given indoor unit needs cleaning. Three lock modes Single/unified control mode Centralized controller MD-CCM09 provides a superior way to manage the indoor units. Users are able to make their own choice from locking the wireless controller, locking the running mode or lock the MD-CCM09’s keyboard as they wish. The control object can be either a single unit or all units, which vastly simplifies the control process. Operation signal feedback ensures that all units are working in the correct mode. OPR.UNSUCCESS Locking Running Mode Locking Remote Controller Locking Keyboard Connecting status matrix MODE AUTO 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 00+ 16+ ROOM.TEMP T3 Hr ON OFF T2A T2B SET.TEMP 32+ FAN Hr Air filter cleaning reminding icon Indoor unit working status display 48+ OPR.UNSUCCESS Access to network monitoring CCM30 The centralized controller can bridge up to 64 indoor units on the network monitoring and building management systems. MD-CCM09 displays indoor units' working status and Error code or protection code error codes so users can easily identify faults via checking the error codes table in the user's manual before contacting a service engineer. GROUP QUERY RUN SET #GROUPALL # ERROR INLINE ON OFF PROTECT MODE AUTO 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 00+ 16+ ROOM.TEMP T3 MAX.64 Connecting status matrix (1.6) # ERROR INLINE ON OFF PROTECT (1.6) GROUP QUERY RUN SET #GROUPALL Hr ON OFF T2A T2B SET.TEMP 32+ FAN Hr 48+ OPR.UNSUCCESS MD-CCM03 Specifications Specifications Model Dimensions (H*W*D)(mm) Power (V) 69 MD-CCM03 CCM30 179×119×74 180×122×78 198-242V(50/60Hz) Model MD-CCM09 Dimensions (H*W*D)(mm) 179×119×74 Power (V) 198-242V(50/60Hz) 70 Control system Control system Indoor unit working status display Error code or protection code AUTO Heating Lock Centralized controller provides a superior way to manage the indoor units. Users are able to make their own choice from locking the wireless controller, locking the running mode or lock the centralized controller's keyboard as they wish. Locking Running Mode X,Y,E Cooling Lock Fan Mode Three lock modes The centralized controller is a multifunctional device that can control up to 64 indoor units within a maximum connection length of 1,200m. The device connects to the master outdoor units of MDV's newly designed products to simplify and centralize the wiring configuration. The two connection modes are as follows: X,Y,E COOL Mode Centralized Controller Weekly Schedule Centralized Controller Centralized Controller Centralized Controller Wired Controller Unified On/Off Controller KJRF-180A Newly designed centralized controller controls up to 16 Auto Mode COOL Mode DRY Mode FAN Mode Heat Water Lock HEAT Mode KJR-90B Unified controller designed with graceful appearance and explicit panel. indoor units and 1 heat pump water heater in addition. Functions Functions Multiple machine control Single/unified control Unified control KJRF-180A is a multi-functional device that can KJRF-180A provides an easy way to control control indoor air conditioners, heat pump water indoor units and water heater. Users can quickly heater, and fresh air units to realize the operation. select the water heater or the fresh air units to KJR-90B offers on/off and heating/cooling functionality for indoor units based on preset temperatures to ensure easy management. adjust their running modes. KJRF-180A KJRF-180A Fresh air Wall Mounted Unit 28°C 20°C cooling heating Centralized control KJR-90B can be used to centrally control up to 16 indoor units. Wall Mounted Unit Wall Mounted Unit Fresh air Water Heater Max.16 Wall Mounted Unit Water Heater Control system Control system Light indicator Stylish design Easy installation KJRF-180A's stylish design suits high-end KJRF-180A offers two different appearances to mostly suit the installation. Both of them are easy to operate. environments. The key lock function is used to prevent operational mistakes. The LEDs on KJR-90B indicate the indoor units' running status for easy fault detection. The lights switch off automatically to save energy once a given operation is complete. The indicators are as follows: Light Single On/Off key Blue Red Cooling/Fan Heating Flash IDU Error EEPROM Error Unified On/Off key Easy installation KJR-90B can be easily mounted on the built-in cabinet: Specifications Specifications Model KJRF-180A Model KJR-90B Dimensions (H*W*D)(mm) 180×122×69 Dimensions (H*W*D)(mm) 90×86×8 Power (V) 71 220V(50/60Hz) Power (V) DC 5V 72 Central Control Software Various Managements IMM Simple Operation and Management 4th Generation Monitoring System Click & Operate, a user-friendly interface allows even non-experts to perform the building management system easily. Data Management Functions Operational information of individual indoor units are monitored, allowing for distribution of power consumption at outdoor units. Stores operation data on multiple systems and displays it in graphical format for visual management. Uses IMM software to generate tenant reports and help building owners bill for energy use. IMM, designed specifically to control VRF systems, is based on a centralized format and dedicated to the complete control and monitoring of all the system’s functions. It can be used as a flexible multi-purpose system and applied to a variety of needs, according to the scale, purpose and control method of each building. Up to 4 M-interfaces, 64 refrigerant systems, 1,024 indoor units, and 256 outdoor units can be controlled by one PC. Web Access Proportional power distribution User friendly operation Generate operational history reports (daily, weekly, monthly) Fault display & Warning message Central building monitoring and control Lock control (individual controllers) Set temperature limit Electricity Charge Distribution Annual schedule control Low-load operation indicate Filter replacement reminder Emergency stop and Alarm signal output Can run on Window 7_32 bit and Window XP_32 bit. Can monitor and control A/C anytime, anywhere by PC, phone, pad and notebook computer. Support WEB access: IE, Firefox, Safari and Chrome. Enables remote access through DSL, VPNs and so on. Uses software to calculate electric power proportional distribution, output and save electricity consumption data for each indoor unit (or group) which is connected to the intelligent manager. Applies the patented MDV Calculation Method to calculate consumption rates according to capacity demand which is based on various parameters: setting temperature, room temperature, running mode, rated HP, public areas, unused rooms, and nighttime use; outputs this information on a charge calculation sheet to evenly divide power consumption charges among tenants. Hightlights Web Access function Visual Navigation With the web access function, a PC, laptop computer or a smart phone can be used as a remote controller. Clicking the jump button will display a list of all available screens. Clicking the back button will return to the previous screen. Energy Saving Management Data Backup Based on a predetermined schedule, the Intelligent Manager executes capacity control and intermittent operations on all air conditioning units to maintain a high comfort index. The M-interface will automatically back up data on the installed SD card (2GB) in case system failure occurs, such as: power failure or system dam. IMM software also stores the previous 3 months' operational data on the HDD. Schedule Control Multiple Lauguages Automatically performs facility start/stop control, switches the operating mode, sets temperatures and enables/disables the remote control according to the present time schedule. 4 sections and 20 actions per day for each single unit or group. Provides eight language settings: Warning Message Electricity Charge Distribution The system can receive error messages from air conditioning units in more than one buildings or structures via public phone lines. *Requires the MDV "SMS Modem" to send automatic warning messages to designated phone numbers. English French Italian Russian German Spanish Simple Chinese Traditional Chinese Control system Control system Network Control Application Provides information on proportional electrical power distribution to optimize electricity consumption management. Electricity charges can be easily divided when billing users for air conditioning power charges; for example, for tenants in a commercial building, offices in a rented building, or rooms in a hotel. Max.IDU:1024 73 74 Accessories BACnet® BMS Gateway Accessories Modbus BMS Gateway Supports Modbus protocol networks Bridges the MDV central A/C system and the BMS Establishes a Modbus network comprising up to 1,024 indoor units and 64 outdoor units Transfers data in RTU mode Provides a wide voltage range: 12-48V DC MD-CCM08 Contains 4 groups of RS-485 communication ports and be able to connect up to 256 indoor units or 128 outdoor units to the BMS. Be free to connect to the BMS or not. Network Example Network example Network example Indoor Units Max.64 P,Q,E Outdoor units MD-CCM08 F1,F2,E Indoor units CCM03 K1,K2,E CCM02 Modbus Gateway Modbus Master CCM03 RS485 Outdoor units Outdoor Units CCM02 P,Q,E HUB CCM03 BACnet/IP protocol TCP/IP Max.64 K1,K2,E CCM02 BMS Max.16 Max.64 P,Q,E CCM03 Monitoring units online MD-CCM08 allows users to track units' operational status and change their running parameters on Internet Explorer for maximum control convenience Wide compatibility SIMENS APOGEE Brand APOGEE A N Y W H E R E Config A/C System via Web Dimensions Once the Modbus network is set, users can conveniently configure their A/C network system over the Internet using different TCP/IP browsers. The Modbus Gateway is designed with a small size. It’s equipped a installation track for the easy on-site installation. Tracer Summit 10.5 Honeywell Alerton 4 Schneider Andover 25.5 3 Right Side 10.5 5 75 Johnson METASYS Front Side 36 48 TRACER SUMMT 110 BMS software TRANE CCM02 35 Company TM 2 Modbus Gateway One Modbus gateway can bridge one refrigerant system with a PC or the Modbus master. CCM08 has a wonderful adaptability to the BMS 1 Control system Control system Monitoring system Modbus Gateway Indoor units CCM03 Installation Track 100 46 76 Accessories LonGW64® BMS Gateway Accessories 3-Phase Protector HWUA/DPB71CM48 MD-LonGW64 Detect the power condition and make the corresponding protecting action. Protect the compressor from being damaged. Automatically distinguish the abnormal power supply conditions and automatically recover. The new Lonworks gateway has been compliance with LonMark standard. It can connect up to 64 indoor units to the BMS. It realize non-polarity communication,and also the application can be download online. HWUA DPB71CM48 Excellent reliability Network example The protector protects the entire system from power supply problems, and auto restart after recovery. MD-LonGW64 RS485 X,Y,E BMS system RS485 P,Q,E X,Y,E P,Q,E X,Y,E X,Y,E P,Q,E Specifications HWUA Power supply (V-N-Hz) MD-LonGW64 2.9 VA 12% 12% 18% 18% Under voltage -12% -12% -12% -12% 8% / 8% 8% 90×69×35 81×67.2×17.5 90×69×35 81×67×35 Dimensions(W×H×D)(mm) -20 C ~50 -20 C ~50 C 2.9 VA 13 VA Calculates power consumption. Does not need adjusting after long-term use. Corresponds one outdoor unit to one digital power meter. KJR-10B MD-NIM05 MD-NIM05 220V CN CN 2 1 LCD Impulse A phase B phase C phase The digital power meter is tested after manufacture so it can be immediately deployment and used on-site. The LED indicators and installation schematic are shown in the figure on the left. 131 145 Card key AC contactor Wired controller is necessary in this card-key system. Specifications Dimensions (H*W*D)(mm) KM 15mm long crack 72 201 The digital power meter consumes minimal energy. Voltage circuit: less than2W/10VA Current circuit: less than 2.5VA Indications and installation 230 Low power consumption Electrical wiring KJR-10B Model 81×67.2×17.5 DTS634/DTS636 Cooperate with the wired controller to automate control. Eliminates the need for high voltage power, making the device safe and steady. Includes a build-in auto-restart function. Card key / Digital Power Meter MD-NIM05 Installation example 208~480V-3N 50/60Hz Control system Control system Hotel Card Key Interface Module DPA51CM44 50Hz: -20 C~60 C 60Hz:-20 C~50 C 13 VA -20 C~50 C 177~265V AC(50Hz/60Hz) Power (V) 77 DPB71CM48 Over voltage Phase imbalance 31.9×25.1×6.1 Dimensions (H*W*D)(mm) HWUA 50Hz: -20 C ~60 C 60Hz:-20 C ~50 C 7 VA Rated operational power(VA) Model DPA53CM23 Without over/under voltage function 220~480V-3N 50/60Hz 208~480V-3N 50/60Hz 220~480V-3N 50/60Hz 380~480V-3N 50/60Hz Temp. range( C) Specifications Power (V) With over/under voltage function Model X,Y,E Specifications MD-NIM05 86×72.8×15.5 DC 5V Model Dimensions (H*W*D)(mm) Power (V) DTS634/DTS636 230×145×72 200V-500V(50/60Hz) 78 Accessories Outdoor Centralized Controller Accessories Remote Alarm Controller KJR-32B MD-CCM02 COOL lock HEAT lock With the outdoor units communication With the PC or gateway communication Functions Simple design Forced Cooling Forced Cooling Low Middle High Functions ODU parameters display MD-CCM02 enables users to easily check outdoor units' running status, including frequency, temperature, current, pressure, protection codes and error codes. KJR-32B is specially designed for engineering applications. It does not display the ODU’s working parameters, but it can connect to the alarm device when ODU is working abnormally, the RUN light will flash. Specifications Model KJR-32B Dimensions (H*W*D)(mm) 150×85×70 198-242V(50/60Hz) Power (V) Indoor Unit Group Controller Forced Cooling KJR-150A Control system Graph 2 LCD Screen KJR-150A is specially designed for V4 Plus indoor units. A group controller can connect up to 16 V4 plus indoor units through X1 Y1 E, but it cannot directly connect to the central controller. If you need to use a central controller or a PC, you can connect to the XYE from an outdoor unit. A group controller can control a group of indoor units simultaneously, and query the running status of each unit in the group via the display panel. Access to network monitoring K1,K2,E Max.4 System wiring diagram PQE system 1 Max.32 K1,K2,E KJR-150A 1# Max.4 X system 2 MD-CCM02 can connect up to 8 refrigerant systems and 32 outdoor units to the network monitoring and building management systems. Y E V4+ Outdoor Unit V4+ indoor unit(1#) X Y E V4+ indoor unit (2#) X Y E V4+ indoor unit (3#) X Y V4+ indoor unit N# (N≤16) E X Y E PQE KJR-150A 2# V4+ indoor unit(1#) V4+ indoor unit (2#) V4+ indoor unit (3#) V4+ indoor unit N# (N≤16) XYE POWER X X Y E X Y E X Y E X Y E X Y Y E E Centr alized contr oller K1,K2,E PQE Max.4 KJR-150A N# X system 8 Model Model MD-CCM02 Dimensions(H×W×D)(mm) 120×120×15 79 E X Y E V4+ indoor unit (2#) X Y E V4+ indoor unit (3#) E Y V4+ indoor unit N# (N≤16) X X Y NOTE : The Maximum Number of Indoor units is 64. E Specifications Specifications Power (V) Y V4+ indoor unit(1#) Dimensions (H*W*D)(mm) Power (V) KJR-32B 150×85×70 198-242V(50/60Hz) 198-242V(50/60Hz) 80 Control system Functions Simple design Accessories Accessories Control Box HRV Wired Controller KJR-27B CE-AHUKZ-01/CE-AHUKZ-02 Functions Introduction V4+ functions inside. Match the new outdoor units. HRV controller Built-in timer KJR-27B is individually designed for HRV—Heat Recovery Ventilator. The HRV can work in the following modes: exhaust, air supply, bypass, heat exchange, and auto. Built-in daily timer offers the convenience of automatically starting and stopping the HRV at the set times. CE-AHUKZ-01/CE-AHUKZ-02 is an independent control box that can connect a AHU to V4 Plus system to realize centralized control with V4 Plus system. Control box wiring is as follows: Power supply Centralized Controller Setup screen example Set to wednesday: 8:00 to 20:00 0 3 6 P/Q/E 24°C ON AUTO->HEAT EXCHANGE-> EXHAUST->BYPASS->AIR SUPPLY 9 12 Power supply 15 X/Y/E OFF 18 21 Time Wired Controller T1/T2/T2B Specifications G/L pipe Model KJR-27B Dimensions(H×W×D)(mm) Power supply 120×120×15 Power (V) 198-242V(50/60Hz) Specifications Model KJR-31B Dimensions(H×W×D)(mm) Power (V) Functions KJR-31B can lock the running mode of the indoor units to avoid mis-operations and mode conflicts. Wiring diagram KJR-31B can lock the running mode of up to 64 indoor units. X,Y,E Max.64 Specifications 81 198V-220V(50/60Hz) Display the outdoor units’ real-time running conditions. Automatically outputs running status charts. Supports V3, V4, V4+, D3, D4 outdoor units. Multiple device control Power (V) 485×395×205 MDV Outdoor Unit Diagnosis Software MCAC-DIAG/E Running mode locking Dimensions (H*W*D)(mm) CE-AHUKZ-01/CE-AHUKZ-02 Control system Control system Mode Locking Controller Model Fan/pump The diagnostic software applies to K1, K2, E of the outdoor units. The corresponding wiring diagram is shown in the figure on the right. 485A-I K1,K2,E Recommended config KJR-31B Operating system WIN XP SP4/WIN 7 120×120×15 CPU Pentium 4 2G or above 198-242V(50/60Hz) HDD 30G free space Interface port RS-232 terminal 82 Selection software To meet consultants’ and distributors’ requirements, MDV has developed a new program for designing V4 Plus systems. The software provides quick and convenient selectable options for users, supports multiple languages, and greatly improves the selection process. Project Contains project information such as project name, nation, location, and detailed climate data to ensure the optimum system is selected. A/C selection Control system There are 15 types and 100 models of indoor units and all kinds of different power of outdoor units for choosing. Controller selection Provides a selection of controllers for indoor units and outdoor units, including wireless and remote controllers for indoor units. 83 Load calculation Provides two calculation methods: (1)Directly put the room load, or; (2) Detailed parameters, including room area, estimated cooling/heating load index, heating capacity and cooling capacity. Piping drawing Displays the detailed layout of an A/C system and the parameters for piping and branch distributors. Report output Outputs a comprehensive selection report as a Word or PDF document. HRV Heat recovery ventilator HRV Multiple modes for different scenarios Heat exchange mode Heat recovery ventilator When the airflow generated by fans travels across the heat exchange core, the temperature difference between the two channels of the core causes natural thermal transmission. On summer days, hot outdoor air is cooled by the indoor exhaust air; in winter, cold outdoor air is heated by the indoor exhaust air. The energy contained in the exhaust air can be reclaimed to improve energy efficiency. Model Names Larger air supply rate enhanced heat exchange efficiency enhanced energy saving HRV-200 HRV-300 HRV-400 HRV-500 HRV-800 HRV-1000 Bypass mode the heat energy lost through ventilation and In mild climates where the temperature and humidity difference between indoors and outdoors is small, the unit works as conventional ventilation fan. Both the supply fan and exhaust fan work at the same speed (auto/low/medium/high). the ventilation process. By utilizing the latest technologies and techniques, MDV HRV guarantees outstanding performance. The heat HRV-1500 HRV-2000 humidity in a given room. Temperature exchange efficiency exceeds 65%, and enthalpy exchange efficiency ranges from 50 to 65%. RA (Returm air SA SA Damper EA RA Element OA SA Exhaust air mode Auto mode It is also one kind of bypass mode with exhaust fan speed higher than air supply fan speed. It can be used in mild climate area where large amount exhaust air needs to be expelled. The controller chooses heat exchange mode or bypass mode according to the temperature difference between outdoor and indoor temperature. Both the two fans work at low speed. Interlocking control with other indoor units via controller is possible HRV (Supply air to room) Moisture Warm air 。 20°C C EA OA HRV SA 0 0°C Heat OA Flexible control from room) 14。 C Cold air 6。 C Element It is one kind of bypass mode with air supply fan speed higher than exhaust fan speed. It can be used in mild climate area where large amount fresh air is needed. paper that optimally controls temperature and EA RA Air supply mode exchange core is made of chemically treated Heat Moisture Damper EA Bypass mode The heat recovery ventilator (HRV) can reclaim reduce room temperature fluctuations caused by Heat exchange mode Duct (Obtain locally) IDU Heat exchange plate IDU EA (EXhust air to outdoors) Low noise RA SA Centralized control SA CCM03 OA (Fresh air from outdoors) Sound proof material is used to guarantee quiet operation. Compact design, flexible installation and easy maintenance With a height of just 264mm and a weight of 23kg, the unit can be easily installed in a limited space. 85 264mm 86 Specifications Model HRV-400 HRV-500 65 65 65 65 65 65 65 70 70 70 70 High 50 50 50 50 Medium 50 50 50 50 55 55 55 55 55 55 60 60 Medium 55 55 60 60 Low 60 60 65 65 Heat High 27 30 32 35 Exchange Medium 26 29 31 34 Mode Low 20 23 25 28 28 31 33 36 Medium 27 30 32 35 Low 22 25 27 30 mm 866×655×264 944×722×270 944×927×270 10,38×1,026×270 kg 23 26 31 41 Power Supply HRV-200 HRV-300 65 V/ph/Hz % Temp. Exchange Efficiency (%) [50Hz] Enthalpy For Cooling Exchange Low Efficiency (%) High For Heating [50Hz] Sound Level High Bypass Mode Dimensions(W×D×H) Machine Weight Casing Heat Exchange System Heat Exchange Element Material Type Airflow Rate [50Hz] Fan ESP (Pa) [50Hz] % dB(A) 220-240/1/50 - Galvanized steel plate - Air to air cross flow total heat (Sensible heat + latent heat) exchange - Specially processed nonflammable paper 200 Centrifugal fan 300 400 500 200 300 400 500 Low 150 225 300 375 High 75 75 80 80 58 60 65 68 35 40 43 45 W 20 40 80 120 Φ/mm 144 144 144 '-7°C-43°C (DB), 80%RH or less 194 High Medium Medium m3/h Pa Low Motor Output Duct diameter - Operation ambient condition Specifications Model HRV-800 HRV-1000 HRV-1500 65 65 65 65 65 65 / / 70 70 / / High 50 50 50 50 / Power Supply V/ph/Hz % Temp. Exchange Efficiency (%) [50Hz] Enthalpy For Cooling 220-240/1/50 HRV-2000 380/3/50 HRV Medium 50 50 / Exchange Low 55 55 / / Efficiency (%) High 60 60 60 60 Medium 60 60 / / Low 65 65 / / Heat High 39 40 51 53 Exchange Medium 38 39 / / Mode Low 32 33 / / 40 41 52 54 Medium 39 40 / / Low 34 35 / / mm 1,286×1,006×388 1,286×1,256×388 1,600×1,270×540 1,650×1,470×540 kg 62 79 163 182 For Heating [50Hz] Sound Level High Bypass Mode Dimensions(W×D×H) Machine Weight Casing Heat Exchange System Heat Exchange Element Material Type Airflow Rate [50Hz] Fan ESP (Pa) [50Hz] % dB(A) - Galvanized steel plate - Air to air cross flow total heat (Sensible heat + latent heat) exchange - Specially processed nonflammable paper 800 Centrifugal fan 1,000 1,500 2,000 800 1,000 / / Low 600 750 / / High 100 100 160 170 82 85 / / 54 58 / / 360 360 450 450 High Medium Medium m3/h Pa Low Motor Output W 242 242 346×326 Φ/mm '-7°C-43°C (DB), 80%RH or less Operation ambient condition Note: 1. Three speeds (low/med/high) are available for HRV models 200 to 1000; one speed is available for HRV models 1500 to 2000. 2. The sound level is measured at 1.4m below the body center in an anechoic chamber. 3. The airflow rate can transmit between low and high modes. 4. The temperature exchange efficiency is the mean value between cooling and heating 5. Efficiency is measured under the following conditions: * Cooling Condition: Air Exhaust Temp. 27°C DB,19.5°CWB., Fresh Air Temp. 35°C DB,28°CWB * Heating Condition: Air Exhaust Temp. 21°C DB,13°CWB., Fresh Air Temp. 5°C DB,2°CWB Duct diameter 87 346×326 Accessories Accessories 89 ID:9.5 ID:12.7 OD:12.7 OD:9.5 ID:9.5 OD:12.7 ID:9.5 ID:6.4 ID:12.7 OD:12.7 ID:6.4 ID:9.5 ID:6.4 ID:9.5 OD:12.7 ID:9.5 ID:15.9 ID:25.4 OD:9.5 ID:19.1 ID:6.4 OD:19.1 ID:15.9 ID:19.1 OD:15.9 OD:19.1 ID:19.1 ID:22.2 OD:22.2 ID:22.2 ID:25.4 ID:22.2 OD:19.1 OD:22.2 OD:22.2 (ID:15.9) (ID:19.1) ID:9.5 ID:12.7 (ID:19.1) ID:15.9 ID:15.9 ID:15.9 OD:15.9 OD:15.9 (ID:12.7) OD:19.1 ID:19.1 (ID:12.7) ID:9.5 (ID:15.9) ID:12.7 ID:9.5 ID:6.4 ID:31.8 OD:28.6 ID:28.6 ID:28.6 ID:34.9 ID:38.1 ID:12.7 ID:41.3 ID:34.9 A*:The total capacity of indoor units following this branch joint ID:22.2 OD:22.2 OD:28.6 FQZHN-05C SBH-04 ID:44.5 units (optional) ID:41.3 SBH-03 OD:41.3 pressure duct indoor Drain pump kit ID:22.2 For high static ID:34.9 Accessories SBH-01 OD:28.6 92kW≤A* ID:34.9 365×110×205 / 1.6 FQZHN-05C FQZHN-04C ID:44.5 66kW≤A*<92kW FQZHN-04C ID:22.2 350×70×170 / 1.3 indoor unit ID:19.1 33kW≤A*<66kW OD:34.9 310×70×125 / 0.87 ID:15.9 FQZHN-03C OD:34.9 16.6≤A*<33kW ID:28.6 280×50×95 / 0.6 ID:28.6 FQZHN-02C FQZHN-03C ID:22.2 A*<16.6kW ID:22.2 255×50×90 / 0.48 Accessories FQZHN-01C ID:19.1 Branch joint for R410A OD:22.2 (ID:15.9) ID:15.9 For four outdoor units connection ID:41.3 465×115×255 / 4 ID:19.1 FQZHW-04N1C (ID:19.1) ID:12.7 FQZHN-02C OD:34.9 outdoor unit ID:19.1 For three outdoor units connection (ID:19.1) FQZHW-03N1C ID:22.2 465×85×265 / 2.7 FQZHN-01C ID:15.9 Branch joint for 410A OD:19.1 For two outdoor units connection Liquid Side Joints OD:19.1 455×55×185 / 1.4 Gas side joints ID:12.7 FQZHW-02N1C Name OD:22.2 Model name Indoor branch drawing Description (ID:15.9) Features Packing Size (mm)/ Gross Weight (kg) ID:12.7 Model Refrigerant Distributors 90 Memo Outdoor branch drawing Outdoor branch FQZHW-02N1C FQZHW-03N1C FQZHW-04N1C 0D:31.8 0D:31.8 ID:25.4 ID:31.8 ID:25.4 0D:31.8 Q2 ID:31.8 ID:25.4 Q1 Q2 Q1 Q2 0D:31.8 Q7 0D:34.9 ID:31.8 ID:25.4 0D:34.9 Q1 ID:31.8 ID:31.8 Q7 ID:31.8 ID:38.1 ID:25.4 ID:31.8 ID:34.9 0D:31.8 ID:34.9 ID:38.1 0D:31.8 ID:25.4 ID:38.1 ID:41.3 ID:31.8 Gas side Q5 ID:34.9 Q4 Q1 ID:38.1 ID:41.3 ID:31.8 ID:31.8 ID:31.8 0D:31.8 ID:25.4 Q5 ID:44.5 Q1 0D:34.9 ID:41.3 ID:31.8 ID:31.8 Q6 0D:31.8 ID:25.4 Q3 Q1 ID:38.1 ID:31.8 ID:34.9 ID:25.4 0D:15.9 ID:19.1 Y2 ID:12.7 ID:19.1 Y2 0D:15.9 0D:15.9 ID:12.7 ID:19.1 Liquid side Y6 Y1 ID:15.9 ID:15.9 0D:15.9 ID:12.7 ID:19.1 ID:22.2 0D:19.1 ID:19.1 Y2 ID:15.9 ID:15.9 ID:15.9 ID:12.7 Y6 Y1 ID:15.9 0D:31.8 0D:15.9 ID:15.9 ID:12.7 Y6 Y1 ID:15.9 0D:15.9 ID:15.9 ID:12.7 ID:31.8 ID:22.2 Y7 Y7 Y1 ID:15.9 ID:19.1 ID:12.7 ID:15.9 0D:15.9 0D:22.2 Y4 ID:19.1 Y1 Accessories Accessories Y3 ID:22.2 ID:15.9 ID:15.9 0D:15.9 ID:12.7 ID:22.2 0D:25.4 ID:25.4 Y5 Y8 ID:22.2 Y1 ID:15.9 ID:15.9 0D:15.9 ID:12.7 ID:6.4 ID:6.4 Oil balance pipe P 91 P(2pcs) 92