Transcript
DATA SHEET
CP 64S COMMERCIAL PROCESSOR
PAGING ZONE ASSIGN PAGE 1 PAGE 2 1 2 1 2 RMT 1&2 RMT 1&2
ZONE 2
LINE 1
LINE 2
LINE 3
4
6
4
6
4
6
4
6
4
6
0
10
0
10
0
10
0
10
0
10
2
ACTIVE
PROGRAM INPUT LEVELS
LEVEL
ZONE 1
8
2
8
2
8
2
8
2
ZONE 1
8
4
6
0
10
2
ZONE 2
DUCKER PROGRAM DEPTH SELECT L2 L3 L1 P
PRIORITY
8
LEVEL 4
6
0
10
2
OFF
ON
ACTIVE
RMT
ZONE 1
DUCKER PROGRAM DEPTH SELECT L2 L3 L1 P 8
0
10
ON
SIG OL
RMT
12 •
6
2
OFF
ZONE 2 +
LEVEL 4
SIG OL
6
CP 64S
•
0
COMMERCIAL PROCESSOR
•
8
6 •
12
40
100
250
630
1.6k
4k
10k
40
100
250
630
1.6k
4k
10k
POWER
Optional SCP 2 Equalizer-only Security Cover General Description The CP 64S is a versatile commercial preamplifier designed for use in restaurants, bars, health clubs and offices. The CP 64S is capable of serving two independent Zones. Two gated Paging inputs and four Program inputs are provided. Ports are provided for expansion of Page, Program or Zone signals. Four levels of priority are supported: • Priority Page • Non-Priority Page • Priority Program • Non-Priority Program The versatility of the CP 64S allows a wide variety of system configurations while providing simple and intuitive controls. Two gated Paging Inputs capable of receiving mic or line level input are provided. Each features independent Mic/Line Pad, Gain Trim, detector Threshold, Zone Assign and Zone Level controls. Internally selectable phantom power is provided for each input. Each Paging input may be summed Pre- or PostZone Level control to allow setting Paging Level independent of Zone Level. An internal Paging Priority switch allows a “master” pager to override non-priority paging in its assigned zones, while allowing true dual zone independent paging. If no Paging Priority is selected, the Paging inputs mix together for applications like karaoke.
Four stereo Program inputs are provided with independent Input Level controls. Any one of the four Program inputs may be independently assigned in each Zone. One of the Program inputs is a gated Priority Program input. When signal is detected at its input, it overrides any non-priority Program selection in the assigned Zones. The Priority detector features internal, adjustable Threshold and Release-Time controls. The CP 64S has two Zone outputs: Zone 1 is stereo: Zone 2 is mono. Each Zone features independent: • Level • Program Select • Ducker On/Off • Ducker Depth • Servo-Locked-Limiter™ • 7 Band EQ (±12 dB) Versatile wired remote control interface ports are provided for Paging assignment, Zone Level and Zone Program source selection. Paging Zone and Source/Volume remote controls are available as accessories. An optional security cover is available for the CP 64S’s front panel. Front panel Ducker Depth controls are screw driver adjust. All other front panel knobs can be removed and replaced with hole plugs. The remote controls allow blank Decora™ switch covers to act as remote control security covers. The remote knobs can also be replaced with the included hole plugs.
Features • • • • • •
Two fully independent gated Mic/Line Paging Inputs Three stereo Program Inputs Paging Priority Assign Page Ducking One gated stereo Priority Program Input Page / Program / Zone Expansion
• • • • • •
7-Band graphic EQ for each Zone Servo-Locked-Limiter™ for each Zone Optional SCP 2 Security Cover for EQ section only Optional PR 2 Remote Page Assign Remote Optional ZR 1 Remote Zone Level/Program Select Remote NEW! Universal Internal Power Supply (100-240 VAC) Data Sheet-
CP 64S COMMERCIAL PROCESSOR Features and Specifications Parameter MIC/LINE PAGING INPUTS ..........Input Type ..........RFI Filter ..........Gain range ..........Frequency Response ..........Input Referred Noise ..........CMR ..........THD+N ..........Phantom Power ..........Mic Input impedance ..........Line Pad ..........Line Input impedance ..........Signal Detector Range ..........Signal Detector Attack ..........Signal Detector Release ..........Overload Indicator ..........Front Panel Zone Assign ..........Remote Zone Assign ..........Pre/Post Paging assign ..........Page Priority Assign ..........Paging Zone Level Adjust ..........Page Remote Selector
PROGRAM INPUTS ..........Input Type ..........Input Level adjust ..........Frequency Response ..........Input impedance .....Priority Program Input ...............Input Detector Range ...............Release Time Range ...............Attack Time ...............Assign EXPAND OUTPUTS ..........Number of Expand Outputs ..........Expand Selector ..........Output Type ..........Gain: Zone ....................Page/Program ..........Frequency Response
Data Sheet-
Specification Two mono Euroblock Yes +30 to +60 30 Hz to 40 kHz -125 40 .05 +15 500 30 14.5k off to +4 .5 3 +16 Remote, Z1, Z2, Both Off, Z1, Z2, Both
Limit
Units
Conditions/Comments All controls duplicated for both inputs Balanced; Instrumentation amplifier
2 +0/-3 1 min .01 4% 1% 1 1% typ typ typ 1
dB dB dBu dB % VDC Ω dB Ω dBu msec sec dBu
Continuously adjustable Maximum gain Gain: 60 dB, Rs: 150 Ω, BW: 20 kHz 20 to 20 kHz Gain: 30 dB, +4 dBu out, 1 kHz, BW: 80 kHz Internal switch Each leg to ground
off to -35 5 to 20 50 OFF, Z1, Z2 or Both
typ typ typ
dBu sec msec
Internal trim, factory set to -50 dBu Internal trim, factory set to 12 seconds For a 20 dB step; Fixed.
Each leg to ground. Defeats phantom power Continuously adjustable Fixed Fixed 4 dB before clipping. Z1 = Zone 1; Z2 = Zone 2 Internal pull-up; Active low; Switch closure to ground or 5 volt TTL logic. Summed with program Pre VCA or Post VCA via Internal switch P1 (Page 1) 1 dBu Priority pager overrides non-priority pager only NO (none) in assigned zones; Selecting NONE allows the P2 (Page 2) two pagers to mix. off to 0 dB Independent for each Zone 11 = Off 1 dBu Internal pull-up. Active low; 10 = Z1 (Zone 1) Switch closure to Ground or 5 volt TTL logic. 01 = Z2 (Zone 2) 00 = Both Four stereo All controls duplicated for all four inputs RCA Unbalanced off to 0 dB 10 Hz to 50 kHz +0/-3 dB 10 k 20% Ω
Two Zone Program only Page only Balanced 12 6 10 Hz to 50 kHz
All controls duplicated for both zones Z1 & Z2, both mono Note: If a Page signal is summed Post-VCA, it is not present on the Expand Zone output. It is available for the Expand Page output. Cross-coupled; Euroblock connector 1 1 +0/-3
dB dB dB continued...
CP 64S COMMERCIAL PROCESSOR
Parameter ..........S/N ..........THD+N ..........Crosstalk ..........Output impedance ..........Maximum Output ZONE OUTPUTS ..........Number of outputs ..........Output Type ..........Gain: From Program Inputs ....................From Page Inputs ..........Frequency Response ..........S/N ..........THD+N ..........Crosstalk ..........Output impedance ..........Maximum Output ..........Signal Present Indicator ..........Overload Indicator ..........Ducker: Enable ...............Depth Range ..........Limiter: Threshold Range ...............Attack Time ...............Release Time ...............Ratio PROGRAM SELECTION ..........Local (Front Panel) ..........Zone RMT Selector
..........Zone RMT Volume (RMT engaged) ..........Off Isolation EQ CIRCUITS ..........Boost/Cut Range ..........ISO Center Frequencies ..........Filter Bandwidth UNIT: Agency Listing ..........Universal Line Voltage ..........Construction ..........Size ..........Weight Shipping: Size ..........Weight
Specification -84 .05 -75 100 +24 dBu Two Euroblock 12 6 10 Hz to 50 kHz -84 .05 -75 100 +20 -20 +16 ON/OFF -50 to -6 -20 to +20 20 250 15:1
Limit 1 .01 max 1% typ
Units dBr % dB Ω
Zone 1 Stereo, Zone 2 mono Balanced; Cross-coupled 1 1 +0/-3 1 .01 max 1% typ typ typ
dB dB dB dBr % dB Ω dBu dBu dBu
typ typ typ typ typ
dB dB msec msec
L1, L2, L3 or P (priority) 11 = L1 10 = L2 00 = L3 01 = P Attenuation = 64 mV/dB Range 0 V to +5 V (0 dB to -78 dB) -80 typ dB +12 to -12 40, 100, 250, 630, 1.6k, 4k, 10k 2 100-240 VAC, 50/60 Hz All Steel 1.75"H x 19"W x 8.5"D 5 lb 4.5" x 20.3" x 13.75" 9 lb
Conditions/Comments re +4 dBu. BW: 20 Hz-20 kHz +4 dBu, 1 kHz, BW: 80 kHz 1 kHz, Rs: 25 Ω, ch/ch Each leg Ri: 2 kΩ
.5 3%
dB Hz
3%
oct
re +4 dBu. BW: 20 Hz-20 kHz +4 dBu, 1 kHz, BW: 80 kHz 1 kHz, Rs: 25 Ω, (L/R or ch/ch) Each leg Ri = 600 Ω Maximum 4 dB before clipping Independently defeatable for each Zone Continuously adjustable Continuously adjustable For a 10 dB step; Fixed. For a 10 dB step; Fixed. Soft knee. Independent for each Zone Internal pull-up. Active low. Switch closure to ground or 5 volt TTL. Gray Code logic. Control element: 2 kΩ pot, reverse-log taper; Or any ground referenced 0-5 VDC control. 1 kHz, Rs: 25 Ω
Zone 1: Stereo 7-band. Zone 2: Mono 7-band. UL/cUL/CE 12 watts 1U (4.4 cm x 48.3 cm x 21.6 cm) (2.3 kg) (11.5 cm x 52 cm x 35 cm) (4.1 kg)
Note: 0 dBu = 0.775 Vrms
Data Sheet-
CP 64S COMMERCIAL PROCESSOR
Block Diagram DEPTH -50dB
LEFT
LINE 1 0 dB
RIGHT
-6dB
PROGRAM
ZONE 2 INPUT SELECTOR
+
PAGE DUCKER
6 dB
+ SIG
ON/OFF
P R O G R A M I N P U T S
+
ZONE
6 dB
PAGE
OL
ZONE 2 EXPAND -
-20dB
Z2 LIMIT THRESHOLD +20dB
+
Z2 PAGE
LEFT
LINE 2 0 dB
Z2 VC
LEFT
Z2 POST PAGE
DEPTH -6dB
-50dB
LINE 3 0 dB
RIGHT
SIG
+
LEFT
DEPTH
PROGRAM
+
OL
PRIORITY
+
ZONE
6 dB
PAGE 0 dB
+
PAGE DUCKER
6 dB
+
-20dB
-
Z1 LIMIT THRESHOLD +20dB
ZONE 1 EXPAND
+
Z1 POST PAGE
-
+
Z1 PAGE 6 dB
ON/OFF
PRGM PRIORITY RELEASE * TIME 12 24 SEC.
-60dBu
-35dBu
Z1 A Z2 B COM
P1
(ACTIVE LOW)
P2
A B
Z1
REMOTE GRAY CODE 11 10 01 00
P1
P1
A B
CH 1 CH 2 CH 3 CH 4
Z2
PROGRAM SELECT
(ACTIVE LOW)
PAGER NONE ASSIGN LOGIC
COM
PAGE ASSIGN
P2
PAGE PRIORITY *
A B COM A B COM
Z1
LOCAL
(FRONT PANEL)
Z2
P2
A B
CHANNEL SELECT AUTO FADE LOGIC
+
COM A B
RMT SEL
COM
ZONE 1 RMT/LOCAL
P + A G PAGE -1 E I N P + U PAGE 2 T S
PAGE OL
A B
ZONE 1 LEVEL
15V PHTM PWR
PAGE 1 DETECT SENS.
-
P2 ACTIVE
30dB PAD
TRIM
Z1 PAGE
Z1 PAGE LEVEL
+
PAGE 2 DETECT SENS.
-
15V PHTM PWR
+4dB
TRIM
30 TO 60dB
PRE/POST VCA
Z2 PAGE LEVEL
DET
(FRONT PANEL) *
Z1 POST PAGE Z2 PRE PAGE
* MIC/ LINE 30dB PAD
LOCAL
Z1 PRE PAGE
P1
30 TO 60dB
RMT
RMT
OR
DET
* MIC/ LINE
+4dB
+
P2
PAGE BRIDGE
PRE/POST VCA * Z2 POST PAGE Z2 PAGE
* INTERNAL CONTROLS
Data Sheet-
+5
COM P1 ACTIVE
-
+
COM
LOCAL ZONE ASSIGN (FRONT PANEL) RMT Z1 Z2 BOTH
OFF Z1 Z2 BOTH
COM
REMOTE ZONE ASSIGN
11 10 01 00
PRIORITY ASSIGN
PAGE DUCKER
A B
7-BAND EQ
Z1 PRE PAGE
ZONE 1 RIGHT
Z1 VC
PRGM PRIORITY THRESHOLD *
OFF Z1 Z2 BOTH
ZONE 1 LEFT
6 dB
Z1 VC
+ MONO *
+
+
7-BAND EQ
PAGE DUCKER
6 dB
ZONE 1 INPUT SELECTOR
RIGHT
-
+
7-BAND EQ
Z2 PRE PAGE
RIGHT
11 10 01 00
ZONE 2
6 dB
ZONE 2 RMT/LOCAL +5
ZONE 2 LEVEL RMT
LOCAL
(FRONT PANEL)
RMT
Z1 VC
+
Z2 VC
CP 64S COMMERCIAL PROCESSOR
Remote Controls
L1
L2 L3
Two optional wired remote control units are available. The PR 2 allows remote control of Page 1 and Page 2 Zone Assign selection. The ZR 1 allows remote control of Zone Level and Zone Program selection. One PR 2 and two ZR 1 remotes may be used with each CP 64S. The PR 2 and ZR 1 may be installed in standard electrical boxes (minimum depth 2.25"). The remotes connect to the CP 64S through Euroblock connectors. The PR 2 is a 5-wire remote with 2 bits to select Page 1 Assign, one wire for shield/gnd and 2 bits for Page 2 Assign. Selector logic is active low BCD with pull-up provided in the CP 64S. Control may be a simple switch closure to ground or 5 volt TTL. Page 1 and Page 2 bits may be paralleled so that one switch controls both Page Assigns. Remote control is initiated by setting the front panel Paging Zone Assign selector to RMT. The ZR 1 is a 5-wire remote with 2 bits for Zone Program selection (active low Gray Code), a common shield/ground and two wires for ratiometric DC control of Zone Level. Zone 1 and Zone 2 ZR 1 remote ports may be paralleled so that a single remote controls both Zones. Selector logic is active low Gray Code with pull-up provided in the CP 64S. Control may be a simple switch closure to ground or 5 volt TTL. Remote control for each zone is initiated by engaging the RMT switch (located on the front panel) for that Zone.
P
PROGRAM SELECT
4
6
0
10
2
ZR 1
8
LEVEL
OFF
Z1 Z2
BOTH
PAGE 1 ASSIGN
OFF
Z1 Z2
PR 2
BOTH
PAGE 2 ASSIGN
Example System: Retail Store CP 64S
COMMERCIAL AUDIO EQUIPMENT 24TJ
100-240 V 50/60 Hz 12 WATTS
Z2 PGM
Z2 LEVEL
OUTPUTS
REMOTES
PROGRAM INPUTS
Z2 EXPAND Z2 MONO
WIRING
+8
ZONE 2 EXPAND OUT ACN 001 345 482
Z1 PGM D1 D0
RANE CORP. MADE IN U.S.A.
ZONE 1 EXPAND OUT
–20
ZONE PAGE ZONE PAGE Z1 LEVEL 2 1 Vr Vc PGM PGM
ZONE 2
PRIORITY ASSIGN ZONE
LIMITER ZONE 1 ZONE 2
MIN MAX Vr Vc
R
Z1 EXPAND Z1 RIGHT + – + –
ZONE 1
Z1 LEFT + –
+8
+20
–20
off 1 +20
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES FOR A CLASS 'B' COMPUTING DEVICE.
Z2 Z1R Z1L EX1 EX2
L
1
1&2
R
PRIORITY
R 3
2
Limit
Fault
6
Comp
Load
Exp
Ready
24
3
3
Limit
Fault
6
Comp
Load
Exp
Ready
12 24
Limit
Fault
6
Comp
Load
Exp
Ready
dB Headroom
PAGE 1 TRIM
REMOTE 2 Z2 Z1
IN1 MUSIC SERVICE
DVR
+30
+60
MIC
LINE
PAGE 1
DETECT THRESHOLD
INPUT 2 + –
IN2
OL +30 MIC
+60
LINE
PRIORITY 1
TELEPHONE PAGE OUT
62 1:58
ON
3
Limit
Fault
6
Comp
Load
Exp
Ready
12
PAGE 2 TRIM
TELEPHONE HOLD MUSIC
4
3 12 24
dB Headroom
PAGE 2
1
PRE-RECORDED ADVERTISEMENT OR BREAK BELL
2
3 12
PAGING INPUTS
Z1 Z2
PRIORITY 2
MA 4 MULTICHANNEL AMPLIFIER
INPUT 1
2
CD PLAYER
dB Headroom
REMOTE 1 REMOTE PAGE ZONE ASSIGN WIRING
L
MA 4 DIGITAL AMPLIFIER
24 dB Headroom
DISTRIBUTED OUTPUTS REQUIRE MT 4 TRANSFORMER ACCESSORY
ZR 1
ZR 1
DISTRIBUTED L1
L2 L3
P
PROGRAM SELECT
4
6
2
8 0
PROGRAM SELECT
STEREO L1
ZONE 2
LEVEL
L2 L3
P
PROGRAM SELECT
4
6
0
10
2
10
LEVEL
8
PROGRAM SELECT
ZONE 1
DISTRIBUTED
EXPAND 1
LEVEL
LEVEL
RETAIL / SHOP FLOOR
MEETING / DEMO ROOM
OFFICE PAGE
Data Sheet-
CP 64S COMMERCIAL PROCESSOR Example System: Auto Dealer and Service CP 64S
Z2 PGM
COMMERCIAL AUDIO EQUIPMENT 24TJ
100-240 V 50/60 Hz 12 WATTS
PROGRAM INPUTS
OUTPUTS Z2 EXPAND Z2 MONO
REMOTES
Z2 LEVEL
WIRING
LIMITER ZONE 1 ZONE 2
MIN MAX Vr Vc
R
ZONE 2 EXPAND OUT ACN 001 345 482
Z1 PGM D1 D0
RANE CORP. MADE IN U.S.A.
+8
ZONE 1 EXPAND OUT
–20
ZONE PAGE ZONE PAGE Z1 LEVEL 2 1 Vr Vc PGM PGM
ZONE 2
Z1 EXPAND Z1 RIGHT + – + –
ZONE 1
Z1 LEFT + –
+8
+20
–20
PRIORITY ASSIGN ZONE off 1
+20
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES FOR A CLASS 'B' COMPUTING DEVICE.
L
REMOTE 1 REMOTE PAGE ZONE ASSIGN WIRING
L
INPUT 1
PAGING INPUTS PAGE 1 TRIM
PAGE 2 TRIM
Z1 Z2
2
R
1&2
PRIORITY
R
3
2
PAGE 2
1
Z2 Z1R Z1L EX1 EX2
MA 3 MULTICHANNEL AMPLIFIER
REMOTE 2 Z2 Z1
INPUT 2 + –
+60
LINE
OL +30 MIC
+60
LINE
IN2 IN1 TO SET PAGE PRIORITY 2 PRIORITY 1 PRIORITY SUM PAGE 1 & PAGE 2 POST VCA
PRIORITY 2 SUM PAGE 2 POST VCA
PRIORITY 4
PRIORITY 3
+30
MIC
PAGE 1
DETECT THRESHOLD
MUSIC SERVICE 10 8:58 1
2 0
0
3
3
3
6
6
12
CD
3
0
POWER
EXPAND 2 MUSIC ON HOLD
MA 3
MULTICHANNEL AMPLIFIER
6
12
12 dB
CHANNEL OUTPUT HEADROOM
PR 2
POWER
OFF
TELEPHONE KEY SERVICE UNIT Z1 Z2
BOTH
PAGE 1 ASSIGN
ZR 1
ZR 1
OFF
Z1 Z2
BOTH
PAGE 2 ASSIGN
L1
L2 L3
DISTRIBUTED (USE MT 4 TRANSFORMER BELOW)
P
PROGRAM SELECT
4
6
0
10
2
ZONE 2
8
L2 L3
L1
RIGHT
P
MASTER PAGE
LEFT
PROGRAM SELECT
4
6
0
10
2
ZONE 1
8
PROMO DVD
SALES & CREDIT OFFICES CP 64S
EXPAND 1 EMERGENCY PAGE
SALES FLOOR
Z2 PGM
COMMERCIAL AUDIO EQUIPMENT 24TJ
100-240 V 50/60 Hz 12 WATTS
Z2 LEVEL
PROGRAM INPUTS
OUTPUTS Z2 EXPAND Z2 MONO
REMOTES
LIMITER ZONE 1 ZONE 2
MIN MAX Vr Vc
R
ZONE 2 EXPAND OUT ACN 001 345 482
Z1 PGM D1 D0
+8
ZONE 1 EXPAND OUT
–20
ZONE PAGE ZONE PAGE Z1 LEVEL 2 1 Vr Vc PGM PGM
ZONE 2
Z1 EXPAND Z1 RIGHT + – + –
ZONE 1
Z2
Z1 LEFT + –
+8
+20
–20
Z1L EX2
PRIORITY ASSIGN ZONE off 1
+20
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES FOR A CLASS 'B' COMPUTING DEVICE.
MA 3 MULTICHANNEL AMPLIFIER
L
REMOTE 1 REMOTE PAGE ZONE ASSIGN WIRING
L
R
1&2
PRIORITY
R
3
2
PAGE 2
1
0
3
3
6
6
6
12
12
REMOTE 2 Z2 Z1
POWER
MA 3
10 8:58
MULTICHANNEL AMPLIFIER
SERVICE RECEPTION
MT 4
ZR 1
ZR 1
P
4
6
0
10
2
8
LEVEL
Data Sheet-
Z1 Z2
DISTRIBUTED
ZONE 2
L1
L2 L3
P
PROGRAM SELECT
4
6
0
10
2
SERVICE WRITER AND PARTS ROOM
DISTRIBUTED
DISTRIBUTED
ZONE 1
EXPAND 2
8
LEVEL
SERVICE BAYS
RESTROOMS
OL +30
PRIORITY 2
MIC OR TELEPHONE PAGE TO SERVICE BOTH
PAGE 1 ASSIGN
HOLE PLUG
POWER
MULTICHANNEL TRANSFORMER
L2 L3
+60
LINE
CD
12
MT 4 MULTICHANNEL TRANSFORMER
L1
INPUT 2 + –
IN1
PRIORITY 3
dB CHANNEL OUTPUT HEADROOM
PROGRAM SELECT
+30
MIC
PAGE 1
DETECT THRESHOLD
3
0
3
PAGE 1 TRIM
PAGE 2 TRIM
OFF 2
PAGING INPUTS
2
PR 2
1
INPUT 1
Z1 Z2
OPTIONAL SOURCES PRIORITY 4 0
SET PAGE PRIORITY TO P2
IN2 PRIORITY 1
WIRING
RANE CORP. MADE IN U.S.A.
RECEPTION
12:00
LEVEL
LEVEL
MIC
+60
LINE
CP 64S COMMERCIAL PROCESSOR Example System: Karaoke Diner CP 64S
Z2 PGM
COMMERCIAL AUDIO EQUIPMENT 24TJ
100-240 V 50/60 Hz 12 WATTS
Z2 LEVEL
OUTPUTS
REMOTES
PROGRAM INPUTS
Z2 EXPAND Z2 MONO
WIRING
LIMITER ZONE 1 ZONE 2
MIN MAX Vr Vc
R
ZONE 2 EXPAND OUT ACN 001 345 482
–20
ZONE PAGE ZONE PAGE Z1 LEVEL 2 1 Vr Vc PGM PGM
Z1 PGM D1 D0
RANE CORP. MADE IN U.S.A.
+8
ZONE 1 EXPAND OUT
ZONE 2
Z1 EXPAND Z1 RIGHT + – + –
ZONE 1
Z2
EX2
+20
–20
off 1 +20
Z1L
L
REMOTE 1 REMOTE PAGE ZONE ASSIGN WIRING
L
R
PRIORITY
R
3
PAGE 2
2
1
1
2
Limit
Fault
6
Comp
Load
Exp
Ready
24
dB Headroom
3
3
Limit
Fault
6
Comp
Load
Exp
Ready
12 24
Limit
Fault
6
Comp
Load
Exp
Ready
24
dB Headroom
Limit
Fault
6
Comp
Load
Exp
Ready
PROGRAM SELECT
P
OFF
TRANSFORMER
MA 4 DIGITAL AMPLIFIER
24
dB Headroom
L2 L3
PROGRAM SELECT
ON
3 12
+30
+60
MIC
LINE
PAGE 1
DETECT THRESHOLD
REMOTE 2 Z2 Z1
INPUT 2 + –
OL +30 MIC
+60
LINE
PR 2
L1
4
3 12
PAGE 1 TRIM
PAGE 2 TRIM
IN2 IN1
ZR 1
3
PAGING INPUTS
Z1 Z2
PRIORITY 1
MA 4 MULTICHANNEL AMPLIFIER 12
INPUT 1
2
1&2
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES FOR A CLASS 'B' COMPUTING DEVICE.
Z1 LEFT + –
Z1R
+8
PRIORITY ASSIGN ZONE
dB Headroom
4
6
0
10
2
LEVEL
8
OFF
SATELLITE AUDIO MUSIC SERVICE
LEVEL
Z1 Z2
PAGE IN LOUNGE OR DINING AREA
BOTH
PAGE 1 ASSIGN
Z1 Z2
BOTH
PAGE 2 ASSIGN
SINGER 1
1-1-05
ZR 1
KARAOKE DVD SINGER 2 or ANNOUNCER or DINING PAGE
CH 68 L1
L2 L3
P
PROGRAM SELECT
4
6
2
8 0
10
PROGRAM SELECT
ZONE 2
LEVEL
DVR
ZONE 1
LEVEL
62 1:58
OTHER PROGRAM SOURCE
KARAOKE LOUNGE
DINING AREA
Example System: Restaurant CP 64S
Z2 PGM
COMMERCIAL AUDIO EQUIPMENT 24TJ
100-240 V 50/60 Hz 12 WATTS
Z2 LEVEL
OUTPUTS
REMOTES
PROGRAM INPUTS
Z2 EXPAND Z2 MONO
WIRING
LIMITER ZONE 1 ZONE 2
MIN MAX Vr Vc
R
ZONE 2 EXPAND OUT ACN 001 345 482
Z1 PGM D1 D0
RANE CORP. MADE IN U.S.A.
ZONE 1
+8
ZONE 1 EXPAND OUT
–20
ZONE PAGE ZONE PAGE Z1 LEVEL 2 1 Vr Vc PGM PGM
Z1 EXPAND Z1 RIGHT + – + –
ZONE 2
+8
+20
–20
off 1 +20
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES FOR A CLASS 'B' COMPUTING DEVICE.
Z1 LEFT + –
Z2 Z1R Z1L EX1 EX2
2
3
Limit
Fault
6
Comp
Load
Exp
Ready
12 24 dB Headroom
3
3
Limit
Fault
6
Comp
Load
Exp
Ready
12 24 dB Headroom
Limit
Fault
6
Comp
Load
Exp
Ready
24
1 4
3 12 dB Headroom
2
3
REMOTE 1 REMOTE PAGE ZONE ASSIGN WIRING
L
INPUT 1
PAGING INPUTS PAGE 2 TRIM
Z1 Z2
PAGE 1 TRIM
2
R
1&2
PRIORITY
R 3
PRIORITY 3
PAGE 2
2
1
REMOTE 2 Z2 Z1
INPUT 2 + –
IN1
PRIORITY 4
+60
LINE
OL +30 MIC
+60
LINE
IN2
PRIORITY 2 PRIORITY 1
MUSIC SERVICE
4
+30
MIC
PAGE 1
DETECT THRESHOLD
PR 2
PAGE 1
ON
3
Limit
Fault
6
Comp
Load
Exp
Ready
12
L
TO TELEPHONE MUSIC-ON-HOLD
MA 4 MULTICHANNEL AMPLIFIER 1
PRIORITY ASSIGN ZONE
MA 4
OFF
DIGITAL AMPLIFIER
24 dB Headroom
CH 68
DVR
MT 4 70V TRANSFORMER
Z1 Z2
BOTH
PAGE 1 ASSIGN
OFF
Z1 Z2
BOTH
PAGE 2 ASSIGN
PAGE ASSIGN HOLE PLUG
10 8:58 MT 4
MULTICHANNEL TRANSFORMER
CD
RECEPTION STATION PR 2
ZONE 2
ZONE 2 EXPAND
ZONE 1 EXPAND
ZONE 1
OFF
PAGE 2 Z1 Z2
BOTH
PAGE 1 ASSIGN
OFF
DISTRIBUTED
ZR 1
ZR 1
L1
L2 L3
P
PROGRAM SELECT
4
6
2
8 0
DISTRIBUTED
DISTRIBUTED
PROGRAM SELECT
PATIO DINING
L1
L2 L3
P
6
2
10
8 0
LEVEL
Z1 Z2
BOTH
PAGE 2 ASSIGN
OFFICE PAGE
RESTROOMS
PROGRAM SELECT
4
LEVEL
DISTRIBUTED
HOLE PLUG
10
PROGRAM SELECT LEVEL
MIC OR TELEPHONE PAGE TELEPHONE KEY SERVICE
10 8 19:58
JUKEBOX
LEVEL
DINING ROOM
LOUNGE
OFFICES
Data Sheet-
CP 64S COMMERCIAL PROCESSOR
Rear Panel CP 64S
COMMERCIAL AUDIO EQUIPMENT 24TJ
100-240 V 50/60 Hz 12 WATTS
Z2 PGM
Z2 LEVEL
PROGRAM INPUTS
Z2 EXPAND Z2 MONO
WIRING
LIMITER ZONE 1 ZONE 2
MIN MAX Vr Vc
R
ZONE 2 EXPAND OUT ACN 001 345 482
RANE CORP. MADE IN U.S.A.
OUTPUTS
REMOTES
Z1 PGM D1 D0
+8
ZONE 1 EXPAND OUT
ZONE PAGE ZONE PAGE Z1 LEVEL 2 1 Vr Vc PGM PGM
–20
Z1 EXPAND Z1 RIGHT + – + –
Z1 LEFT + –
+8
+20
–20
PRIORITY ASSIGN ZONE off 1
+20
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES FOR A CLASS 'B' COMPUTING DEVICE.
L
REMOTE 1 REMOTE PAGE ZONE ASSIGN WIRING
L
INPUT 1
PAGING INPUTS PAGE 2 TRIM
Z1 Z2
PAGE 1 TRIM
2
1&2
R
PRIORITY
R 3
2
PAGE 2
1
+30
+60
MIC
LINE
PAGE 1
DETECT THRESHOLD
REMOTE 2 Z2 Z1
INPUT 2 + –
OL +30 MIC
+60
LINE
Euroblocks are included, removed here for visibility.
Architectural Specifications The processor shall provide two fully independent gated paging inputs, three line-level non-priority program inputs and one gated line-level priority program input. Two zone outputs shall be served. Zone 1 shall be a stereo zone with balanced, crosscoupled outputs. Zone 2 shall be a mono zone with a balanced cross-coupled output. Mono expansion ports for page, program or zone signals shall be provided for each zone. Wired remote control ports shall be provided for paging zone assign, zone program select and zone level. Page inputs shall use a 5-pin Euroblock connector. Paging controls shall include: • 30 dB mic/line input pad. • Input gain trim range of 30 dB to 60 dB. • Mic gate threshold (range -∞ to +4 dBu). • 15 volt phantom power (internal switch). • Paging priority (page 1, none, page 2; internal switch). • Pre- or post-zone level summing (internal switch). • Front panel paging zone assign (Remote, Z1, Z2, Both). • Remote paging zone assign (Off, Z1, Z2, Both). • Paging zone level. Each Program input shall have stereo RCA input jacks and independent input level control. The priority program assign switch shall provide priority program override to zone 1, zone 2, both, or neither (off). The gated priority program input shall have internally adjustable threshold and release time controls.
Zone outputs shall use 3-pin Euroblock connectors. Zone controls shall include: • Ducker on/off • Ducker depth (-6 to -50 dB) • Program select (L1, L2, L3, P) • Zone level • 7-band graphic equalizer (±12 dB) • Servo-Locked-Limiter™ threshold (-20 to +20 dBu) • Mono switch for Zone 1 (internal) • Remote engage switch Wired remote ports shall use 3-pin Euroblock connectors. Remote logic shall be active low with internal pull-up. Remote level control shall be ratiometric DC control with 5 volt reference. The unit shall be capable of operation by means of its own built-in universal power supply operating at 100-240 VAC and meet CE requirements. The unit shall be UL and cUL listed. The unit shall be entirely constructed from cold-rolled steel. Reliability and efficiency are to be primary design considerations. The unit shall be a Rane Corporation CP 64S Commercial Processor.
Available Accessories • • • • •
SCP 2 Security Cover (for EQ section) SC 1.7 Security Cover (for entire front panel) PR 2 Page Assign Remote Control ZR 1 Zone Source/Volume Remote Control Hole Plugs (6 Provided)
©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5098 USA TEL 425-355-6000 FAX 425-347-7757 WEB www.rane.com
Data Sheet-
All features & specifications subject to change without notice. DOC 102906