Preview only show first 10 pages with watermark. For full document please download

Cp 64s Data Sheet

   EMBED


Share

Transcript

DATA SHEET CP 64S COMMERCIAL PROCESSOR PAGING ZONE ASSIGN PAGE 1 PAGE 2 1 2 1 2 RMT 1&2 RMT 1&2 ZONE 2 LINE 1 LINE 2 LINE 3 4 6 4 6 4 6 4 6 4 6 0 10 0 10 0 10 0 10 0 10 2 ACTIVE PROGRAM INPUT LEVELS LEVEL ZONE 1 8 2 8 2 8 2 8 2 ZONE 1 8 4 6 0 10 2 ZONE 2 DUCKER PROGRAM DEPTH SELECT L2 L3 L1 P PRIORITY 8 LEVEL 4 6 0 10 2 OFF ON ACTIVE RMT ZONE 1 DUCKER PROGRAM DEPTH SELECT L2 L3 L1 P 8 0 10 ON SIG OL RMT 12 • 6 2 OFF ZONE 2 + LEVEL 4 SIG OL 6 CP 64S • 0 COMMERCIAL PROCESSOR • 8 6 • 12 40 100 250 630 1.6k 4k 10k 40 100 250 630 1.6k 4k 10k POWER Optional SCP 2 Equalizer-only Security Cover General Description The CP 64S is a versatile commercial preamplifier designed for use in restaurants, bars, health clubs and offices. The CP 64S is capable of serving two independent Zones. Two gated Paging inputs and four Program inputs are provided. Ports are provided for expansion of Page, Program or Zone signals. Four levels of priority are supported: • Priority Page • Non-Priority Page • Priority Program • Non-Priority Program The versatility of the CP 64S allows a wide variety of system configurations while providing simple and intuitive controls. Two gated Paging Inputs capable of receiving mic or line level input are provided. Each features independent Mic/Line Pad, Gain Trim, detector Threshold, Zone Assign and Zone Level controls. Internally selectable phantom power is provided for each input. Each Paging input may be summed Pre- or PostZone Level control to allow setting Paging Level independent of Zone Level. An internal Paging Priority switch allows a “master” pager to override non-priority paging in its assigned zones, while allowing true dual zone independent paging. If no Paging Priority is selected, the Paging inputs mix together for applications like karaoke. Four stereo Program inputs are provided with independent Input Level controls. Any one of the four Program inputs may be independently assigned in each Zone. One of the Program inputs is a gated Priority Program input. When signal is detected at its input, it overrides any non-priority Program selection in the assigned Zones. The Priority detector features internal, adjustable Threshold and Release-Time controls. The CP 64S has two Zone outputs: Zone 1 is stereo: Zone 2 is mono. Each Zone features independent: • Level • Program Select • Ducker On/Off • Ducker Depth • Servo-Locked-Limiter™ • 7 Band EQ (±12 dB) Versatile wired remote control interface ports are provided for Paging assignment, Zone Level and Zone Program source selection. Paging Zone and Source/Volume remote controls are available as accessories. An optional security cover is available for the CP 64S’s front panel. Front panel Ducker Depth controls are screw driver adjust. All other front panel knobs can be removed and replaced with hole plugs. The remote controls allow blank Decora™ switch covers to act as remote control security covers. The remote knobs can also be replaced with the included hole plugs. Features • • • • • • Two fully independent gated Mic/Line Paging Inputs Three stereo Program Inputs Paging Priority Assign Page Ducking One gated stereo Priority Program Input Page / Program / Zone Expansion • • • • • • 7-Band graphic EQ for each Zone Servo-Locked-Limiter™ for each Zone Optional SCP 2 Security Cover for EQ section only Optional PR 2 Remote Page Assign Remote Optional ZR 1 Remote Zone Level/Program Select Remote NEW! Universal Internal Power Supply (100-240 VAC) Data Sheet- CP 64S COMMERCIAL PROCESSOR Features and Specifications Parameter MIC/LINE PAGING INPUTS ..........Input Type ..........RFI Filter ..........Gain range ..........Frequency Response ..........Input Referred Noise ..........CMR ..........THD+N ..........Phantom Power ..........Mic Input impedance ..........Line Pad ..........Line Input impedance ..........Signal Detector Range ..........Signal Detector Attack ..........Signal Detector Release ..........Overload Indicator ..........Front Panel Zone Assign ..........Remote Zone Assign ..........Pre/Post Paging assign ..........Page Priority Assign ..........Paging Zone Level Adjust ..........Page Remote Selector PROGRAM INPUTS ..........Input Type ..........Input Level adjust ..........Frequency Response ..........Input impedance .....Priority Program Input ...............Input Detector Range ...............Release Time Range ...............Attack Time ...............Assign EXPAND OUTPUTS ..........Number of Expand Outputs ..........Expand Selector ..........Output Type ..........Gain: Zone ....................Page/Program ..........Frequency Response Data Sheet- Specification Two mono Euroblock Yes +30 to +60 30 Hz to 40 kHz -125 40 .05 +15 500 30 14.5k off to +4 .5 3 +16 Remote, Z1, Z2, Both Off, Z1, Z2, Both Limit Units Conditions/Comments All controls duplicated for both inputs Balanced; Instrumentation amplifier 2 +0/-3 1 min .01 4% 1% 1 1% typ typ typ 1 dB dB dBu dB % VDC Ω dB Ω dBu msec sec dBu Continuously adjustable Maximum gain Gain: 60 dB, Rs: 150 Ω, BW: 20 kHz 20 to 20 kHz Gain: 30 dB, +4 dBu out, 1 kHz, BW: 80 kHz Internal switch Each leg to ground off to -35 5 to 20 50 OFF, Z1, Z2 or Both typ typ typ dBu sec msec Internal trim, factory set to -50 dBu Internal trim, factory set to 12 seconds For a 20 dB step; Fixed. Each leg to ground. Defeats phantom power Continuously adjustable Fixed Fixed 4 dB before clipping. Z1 = Zone 1; Z2 = Zone 2 Internal pull-up; Active low; Switch closure to ground or 5 volt TTL logic. Summed with program Pre VCA or Post VCA via Internal switch P1 (Page 1) 1 dBu Priority pager overrides non-priority pager only NO (none) in assigned zones; Selecting NONE allows the P2 (Page 2) two pagers to mix. off to 0 dB Independent for each Zone 11 = Off 1 dBu Internal pull-up. Active low; 10 = Z1 (Zone 1) Switch closure to Ground or 5 volt TTL logic. 01 = Z2 (Zone 2) 00 = Both Four stereo All controls duplicated for all four inputs RCA Unbalanced off to 0 dB 10 Hz to 50 kHz +0/-3 dB 10 k 20% Ω Two Zone Program only Page only Balanced 12 6 10 Hz to 50 kHz All controls duplicated for both zones Z1 & Z2, both mono Note: If a Page signal is summed Post-VCA, it is not present on the Expand Zone output. It is available for the Expand Page output. Cross-coupled; Euroblock connector 1 1 +0/-3 dB dB dB continued... CP 64S COMMERCIAL PROCESSOR Parameter ..........S/N ..........THD+N ..........Crosstalk ..........Output impedance ..........Maximum Output ZONE OUTPUTS ..........Number of outputs ..........Output Type ..........Gain: From Program Inputs ....................From Page Inputs ..........Frequency Response ..........S/N ..........THD+N ..........Crosstalk ..........Output impedance ..........Maximum Output ..........Signal Present Indicator ..........Overload Indicator ..........Ducker: Enable ...............Depth Range ..........Limiter: Threshold Range ...............Attack Time ...............Release Time ...............Ratio PROGRAM SELECTION ..........Local (Front Panel) ..........Zone RMT Selector ..........Zone RMT Volume (RMT engaged) ..........Off Isolation EQ CIRCUITS ..........Boost/Cut Range ..........ISO Center Frequencies ..........Filter Bandwidth UNIT: Agency Listing ..........Universal Line Voltage ..........Construction ..........Size ..........Weight Shipping: Size ..........Weight Specification -84 .05 -75 100 +24 dBu Two Euroblock 12 6 10 Hz to 50 kHz -84 .05 -75 100 +20 -20 +16 ON/OFF -50 to -6 -20 to +20 20 250 15:1 Limit 1 .01 max 1% typ Units dBr % dB Ω Zone 1 Stereo, Zone 2 mono Balanced; Cross-coupled 1 1 +0/-3 1 .01 max 1% typ typ typ dB dB dB dBr % dB Ω dBu dBu dBu typ typ typ typ typ dB dB msec msec L1, L2, L3 or P (priority) 11 = L1 10 = L2 00 = L3 01 = P Attenuation = 64 mV/dB Range 0 V to +5 V (0 dB to -78 dB) -80 typ dB +12 to -12 40, 100, 250, 630, 1.6k, 4k, 10k 2 100-240 VAC, 50/60 Hz All Steel 1.75"H x 19"W x 8.5"D 5 lb 4.5" x 20.3" x 13.75" 9 lb Conditions/Comments re +4 dBu. BW: 20 Hz-20 kHz +4 dBu, 1 kHz, BW: 80 kHz 1 kHz, Rs: 25 Ω, ch/ch Each leg Ri: 2 kΩ .5 3% dB Hz 3% oct re +4 dBu. BW: 20 Hz-20 kHz +4 dBu, 1 kHz, BW: 80 kHz 1 kHz, Rs: 25 Ω, (L/R or ch/ch) Each leg Ri = 600 Ω Maximum 4 dB before clipping Independently defeatable for each Zone Continuously adjustable Continuously adjustable For a 10 dB step; Fixed. For a 10 dB step; Fixed. Soft knee. Independent for each Zone Internal pull-up. Active low. Switch closure to ground or 5 volt TTL. Gray Code logic. Control element: 2 kΩ pot, reverse-log taper; Or any ground referenced 0-5 VDC control. 1 kHz, Rs: 25 Ω Zone 1: Stereo 7-band. Zone 2: Mono 7-band. UL/cUL/CE 12 watts 1U (4.4 cm x 48.3 cm x 21.6 cm) (2.3 kg) (11.5 cm x 52 cm x 35 cm) (4.1 kg) Note: 0 dBu = 0.775 Vrms Data Sheet- CP 64S COMMERCIAL PROCESSOR Block Diagram DEPTH -50dB LEFT LINE 1 0 dB RIGHT -6dB PROGRAM ZONE 2 INPUT SELECTOR + PAGE DUCKER 6 dB + SIG ON/OFF P R O G R A M I N P U T S + ZONE 6 dB PAGE OL ZONE 2 EXPAND - -20dB Z2 LIMIT THRESHOLD +20dB + Z2 PAGE LEFT LINE 2 0 dB Z2 VC LEFT Z2 POST PAGE DEPTH -6dB -50dB LINE 3 0 dB RIGHT SIG + LEFT DEPTH PROGRAM + OL PRIORITY + ZONE 6 dB PAGE 0 dB + PAGE DUCKER 6 dB + -20dB - Z1 LIMIT THRESHOLD +20dB ZONE 1 EXPAND + Z1 POST PAGE - + Z1 PAGE 6 dB ON/OFF PRGM PRIORITY RELEASE * TIME 12 24 SEC. -60dBu -35dBu Z1 A Z2 B COM P1 (ACTIVE LOW) P2 A B Z1 REMOTE GRAY CODE 11 10 01 00 P1 P1 A B CH 1 CH 2 CH 3 CH 4 Z2 PROGRAM SELECT (ACTIVE LOW) PAGER NONE ASSIGN LOGIC COM PAGE ASSIGN P2 PAGE PRIORITY * A B COM A B COM Z1 LOCAL (FRONT PANEL) Z2 P2 A B CHANNEL SELECT AUTO FADE LOGIC + COM A B RMT SEL COM ZONE 1 RMT/LOCAL P + A G PAGE -1 E I N P + U PAGE 2 T S PAGE OL A B ZONE 1 LEVEL 15V PHTM PWR PAGE 1 DETECT SENS. - P2 ACTIVE 30dB PAD TRIM Z1 PAGE Z1 PAGE LEVEL + PAGE 2 DETECT SENS. - 15V PHTM PWR +4dB TRIM 30 TO 60dB PRE/POST VCA Z2 PAGE LEVEL DET (FRONT PANEL) * Z1 POST PAGE Z2 PRE PAGE * MIC/ LINE 30dB PAD LOCAL Z1 PRE PAGE P1 30 TO 60dB RMT RMT OR DET * MIC/ LINE +4dB + P2 PAGE BRIDGE PRE/POST VCA * Z2 POST PAGE Z2 PAGE * INTERNAL CONTROLS Data Sheet- +5 COM P1 ACTIVE - + COM LOCAL ZONE ASSIGN (FRONT PANEL) RMT Z1 Z2 BOTH OFF Z1 Z2 BOTH COM REMOTE ZONE ASSIGN 11 10 01 00 PRIORITY ASSIGN PAGE DUCKER A B 7-BAND EQ Z1 PRE PAGE ZONE 1 RIGHT Z1 VC PRGM PRIORITY THRESHOLD * OFF Z1 Z2 BOTH ZONE 1 LEFT 6 dB Z1 VC + MONO * + + 7-BAND EQ PAGE DUCKER 6 dB ZONE 1 INPUT SELECTOR RIGHT - + 7-BAND EQ Z2 PRE PAGE RIGHT 11 10 01 00 ZONE 2 6 dB ZONE 2 RMT/LOCAL +5 ZONE 2 LEVEL RMT LOCAL (FRONT PANEL) RMT Z1 VC + Z2 VC CP 64S COMMERCIAL PROCESSOR Remote Controls L1 L2 L3 Two optional wired remote control units are available. The PR 2 allows remote control of Page 1 and Page 2 Zone Assign selection. The ZR 1 allows remote control of Zone Level and Zone Program selection. One PR 2 and two ZR 1 remotes may be used with each CP 64S. The PR 2 and ZR 1 may be installed in standard electrical boxes (minimum depth 2.25"). The remotes connect to the CP 64S through Euroblock connectors. The PR 2 is a 5-wire remote with 2 bits to select Page 1 Assign, one wire for shield/gnd and 2 bits for Page 2 Assign. Selector logic is active low BCD with pull-up provided in the CP 64S. Control may be a simple switch closure to ground or 5 volt TTL. Page 1 and Page 2 bits may be paralleled so that one switch controls both Page Assigns. Remote control is initiated by setting the front panel Paging Zone Assign selector to RMT. The ZR 1 is a 5-wire remote with 2 bits for Zone Program selection (active low Gray Code), a common shield/ground and two wires for ratiometric DC control of Zone Level. Zone 1 and Zone 2 ZR 1 remote ports may be paralleled so that a single remote controls both Zones. Selector logic is active low Gray Code with pull-up provided in the CP 64S. Control may be a simple switch closure to ground or 5 volt TTL. Remote control for each zone is initiated by engaging the RMT switch (located on the front panel) for that Zone. P PROGRAM SELECT 4 6 0 10 2 ZR 1 8 LEVEL OFF Z1 Z2 BOTH PAGE 1 ASSIGN OFF Z1 Z2 PR 2 BOTH PAGE 2 ASSIGN Example System: Retail Store CP 64S COMMERCIAL AUDIO EQUIPMENT 24TJ 100-240 V 50/60 Hz 12 WATTS Z2 PGM Z2 LEVEL OUTPUTS REMOTES PROGRAM INPUTS Z2 EXPAND Z2 MONO WIRING +8 ZONE 2 EXPAND OUT ACN 001 345 482 Z1 PGM D1 D0 RANE CORP. MADE IN U.S.A. ZONE 1 EXPAND OUT –20 ZONE PAGE ZONE PAGE Z1 LEVEL 2 1 Vr Vc PGM PGM ZONE 2 PRIORITY ASSIGN ZONE LIMITER ZONE 1 ZONE 2 MIN MAX Vr Vc R Z1 EXPAND Z1 RIGHT + – + – ZONE 1 Z1 LEFT + – +8 +20 –20 off 1 +20 THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES FOR A CLASS 'B' COMPUTING DEVICE. Z2 Z1R Z1L EX1 EX2 L 1 1&2 R PRIORITY R 3 2 Limit Fault 6 Comp Load Exp Ready 24 3 3 Limit Fault 6 Comp Load Exp Ready 12 24 Limit Fault 6 Comp Load Exp Ready dB Headroom PAGE 1 TRIM REMOTE 2 Z2 Z1 IN1 MUSIC SERVICE DVR +30 +60 MIC LINE PAGE 1 DETECT THRESHOLD INPUT 2 + – IN2 OL +30 MIC +60 LINE PRIORITY 1 TELEPHONE PAGE OUT 62 1:58 ON 3 Limit Fault 6 Comp Load Exp Ready 12 PAGE 2 TRIM TELEPHONE HOLD MUSIC 4 3 12 24 dB Headroom PAGE 2 1 PRE-RECORDED ADVERTISEMENT OR BREAK BELL 2 3 12 PAGING INPUTS Z1 Z2 PRIORITY 2 MA 4 MULTICHANNEL AMPLIFIER INPUT 1 2 CD PLAYER dB Headroom REMOTE 1 REMOTE PAGE ZONE ASSIGN WIRING L MA 4 DIGITAL AMPLIFIER 24 dB Headroom DISTRIBUTED OUTPUTS REQUIRE MT 4 TRANSFORMER ACCESSORY ZR 1 ZR 1 DISTRIBUTED L1 L2 L3 P PROGRAM SELECT 4 6 2 8 0 PROGRAM SELECT STEREO L1 ZONE 2 LEVEL L2 L3 P PROGRAM SELECT 4 6 0 10 2 10 LEVEL 8 PROGRAM SELECT ZONE 1 DISTRIBUTED EXPAND 1 LEVEL LEVEL RETAIL / SHOP FLOOR MEETING / DEMO ROOM OFFICE PAGE Data Sheet- CP 64S COMMERCIAL PROCESSOR Example System: Auto Dealer and Service CP 64S Z2 PGM COMMERCIAL AUDIO EQUIPMENT 24TJ 100-240 V 50/60 Hz 12 WATTS PROGRAM INPUTS OUTPUTS Z2 EXPAND Z2 MONO REMOTES Z2 LEVEL WIRING LIMITER ZONE 1 ZONE 2 MIN MAX Vr Vc R ZONE 2 EXPAND OUT ACN 001 345 482 Z1 PGM D1 D0 RANE CORP. MADE IN U.S.A. +8 ZONE 1 EXPAND OUT –20 ZONE PAGE ZONE PAGE Z1 LEVEL 2 1 Vr Vc PGM PGM ZONE 2 Z1 EXPAND Z1 RIGHT + – + – ZONE 1 Z1 LEFT + – +8 +20 –20 PRIORITY ASSIGN ZONE off 1 +20 THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES FOR A CLASS 'B' COMPUTING DEVICE. L REMOTE 1 REMOTE PAGE ZONE ASSIGN WIRING L INPUT 1 PAGING INPUTS PAGE 1 TRIM PAGE 2 TRIM Z1 Z2 2 R 1&2 PRIORITY R 3 2 PAGE 2 1 Z2 Z1R Z1L EX1 EX2 MA 3 MULTICHANNEL AMPLIFIER REMOTE 2 Z2 Z1 INPUT 2 + – +60 LINE OL +30 MIC +60 LINE IN2 IN1 TO SET PAGE PRIORITY 2 PRIORITY 1 PRIORITY SUM PAGE 1 & PAGE 2 POST VCA PRIORITY 2 SUM PAGE 2 POST VCA PRIORITY 4 PRIORITY 3 +30 MIC PAGE 1 DETECT THRESHOLD MUSIC SERVICE 10 8:58 1 2 0 0 3 3 3 6 6 12 CD 3 0 POWER EXPAND 2 MUSIC ON HOLD MA 3 MULTICHANNEL AMPLIFIER 6 12 12 dB CHANNEL OUTPUT HEADROOM PR 2 POWER OFF TELEPHONE KEY SERVICE UNIT Z1 Z2 BOTH PAGE 1 ASSIGN ZR 1 ZR 1 OFF Z1 Z2 BOTH PAGE 2 ASSIGN L1 L2 L3 DISTRIBUTED (USE MT 4 TRANSFORMER BELOW) P PROGRAM SELECT 4 6 0 10 2 ZONE 2 8 L2 L3 L1 RIGHT P MASTER PAGE LEFT PROGRAM SELECT 4 6 0 10 2 ZONE 1 8 PROMO DVD SALES & CREDIT OFFICES CP 64S EXPAND 1 EMERGENCY PAGE SALES FLOOR Z2 PGM COMMERCIAL AUDIO EQUIPMENT 24TJ 100-240 V 50/60 Hz 12 WATTS Z2 LEVEL PROGRAM INPUTS OUTPUTS Z2 EXPAND Z2 MONO REMOTES LIMITER ZONE 1 ZONE 2 MIN MAX Vr Vc R ZONE 2 EXPAND OUT ACN 001 345 482 Z1 PGM D1 D0 +8 ZONE 1 EXPAND OUT –20 ZONE PAGE ZONE PAGE Z1 LEVEL 2 1 Vr Vc PGM PGM ZONE 2 Z1 EXPAND Z1 RIGHT + – + – ZONE 1 Z2 Z1 LEFT + – +8 +20 –20 Z1L EX2 PRIORITY ASSIGN ZONE off 1 +20 THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES FOR A CLASS 'B' COMPUTING DEVICE. MA 3 MULTICHANNEL AMPLIFIER L REMOTE 1 REMOTE PAGE ZONE ASSIGN WIRING L R 1&2 PRIORITY R 3 2 PAGE 2 1 0 3 3 6 6 6 12 12 REMOTE 2 Z2 Z1 POWER MA 3 10 8:58 MULTICHANNEL AMPLIFIER SERVICE RECEPTION MT 4 ZR 1 ZR 1 P 4 6 0 10 2 8 LEVEL Data Sheet- Z1 Z2 DISTRIBUTED ZONE 2 L1 L2 L3 P PROGRAM SELECT 4 6 0 10 2 SERVICE WRITER AND PARTS ROOM DISTRIBUTED DISTRIBUTED ZONE 1 EXPAND 2 8 LEVEL SERVICE BAYS RESTROOMS OL +30 PRIORITY 2 MIC OR TELEPHONE PAGE TO SERVICE BOTH PAGE 1 ASSIGN HOLE PLUG POWER MULTICHANNEL TRANSFORMER L2 L3 +60 LINE CD 12 MT 4 MULTICHANNEL TRANSFORMER L1 INPUT 2 + – IN1 PRIORITY 3 dB CHANNEL OUTPUT HEADROOM PROGRAM SELECT +30 MIC PAGE 1 DETECT THRESHOLD 3 0 3 PAGE 1 TRIM PAGE 2 TRIM OFF 2 PAGING INPUTS 2 PR 2 1 INPUT 1 Z1 Z2 OPTIONAL SOURCES PRIORITY 4 0 SET PAGE PRIORITY TO P2 IN2 PRIORITY 1 WIRING RANE CORP. MADE IN U.S.A. RECEPTION 12:00 LEVEL LEVEL MIC +60 LINE CP 64S COMMERCIAL PROCESSOR Example System: Karaoke Diner CP 64S Z2 PGM COMMERCIAL AUDIO EQUIPMENT 24TJ 100-240 V 50/60 Hz 12 WATTS Z2 LEVEL OUTPUTS REMOTES PROGRAM INPUTS Z2 EXPAND Z2 MONO WIRING LIMITER ZONE 1 ZONE 2 MIN MAX Vr Vc R ZONE 2 EXPAND OUT ACN 001 345 482 –20 ZONE PAGE ZONE PAGE Z1 LEVEL 2 1 Vr Vc PGM PGM Z1 PGM D1 D0 RANE CORP. MADE IN U.S.A. +8 ZONE 1 EXPAND OUT ZONE 2 Z1 EXPAND Z1 RIGHT + – + – ZONE 1 Z2 EX2 +20 –20 off 1 +20 Z1L L REMOTE 1 REMOTE PAGE ZONE ASSIGN WIRING L R PRIORITY R 3 PAGE 2 2 1 1 2 Limit Fault 6 Comp Load Exp Ready 24 dB Headroom 3 3 Limit Fault 6 Comp Load Exp Ready 12 24 Limit Fault 6 Comp Load Exp Ready 24 dB Headroom Limit Fault 6 Comp Load Exp Ready PROGRAM SELECT P OFF TRANSFORMER MA 4 DIGITAL AMPLIFIER 24 dB Headroom L2 L3 PROGRAM SELECT ON 3 12 +30 +60 MIC LINE PAGE 1 DETECT THRESHOLD REMOTE 2 Z2 Z1 INPUT 2 + – OL +30 MIC +60 LINE PR 2 L1 4 3 12 PAGE 1 TRIM PAGE 2 TRIM IN2 IN1 ZR 1 3 PAGING INPUTS Z1 Z2 PRIORITY 1 MA 4 MULTICHANNEL AMPLIFIER 12 INPUT 1 2 1&2 THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES FOR A CLASS 'B' COMPUTING DEVICE. Z1 LEFT + – Z1R +8 PRIORITY ASSIGN ZONE dB Headroom 4 6 0 10 2 LEVEL 8 OFF SATELLITE AUDIO MUSIC SERVICE LEVEL Z1 Z2 PAGE IN LOUNGE OR DINING AREA BOTH PAGE 1 ASSIGN Z1 Z2 BOTH PAGE 2 ASSIGN SINGER 1 1-1-05 ZR 1 KARAOKE DVD SINGER 2 or ANNOUNCER or DINING PAGE CH 68 L1 L2 L3 P PROGRAM SELECT 4 6 2 8 0 10 PROGRAM SELECT ZONE 2 LEVEL DVR ZONE 1 LEVEL 62 1:58 OTHER PROGRAM SOURCE KARAOKE LOUNGE DINING AREA Example System: Restaurant CP 64S Z2 PGM COMMERCIAL AUDIO EQUIPMENT 24TJ 100-240 V 50/60 Hz 12 WATTS Z2 LEVEL OUTPUTS REMOTES PROGRAM INPUTS Z2 EXPAND Z2 MONO WIRING LIMITER ZONE 1 ZONE 2 MIN MAX Vr Vc R ZONE 2 EXPAND OUT ACN 001 345 482 Z1 PGM D1 D0 RANE CORP. MADE IN U.S.A. ZONE 1 +8 ZONE 1 EXPAND OUT –20 ZONE PAGE ZONE PAGE Z1 LEVEL 2 1 Vr Vc PGM PGM Z1 EXPAND Z1 RIGHT + – + – ZONE 2 +8 +20 –20 off 1 +20 THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES FOR A CLASS 'B' COMPUTING DEVICE. Z1 LEFT + – Z2 Z1R Z1L EX1 EX2 2 3 Limit Fault 6 Comp Load Exp Ready 12 24 dB Headroom 3 3 Limit Fault 6 Comp Load Exp Ready 12 24 dB Headroom Limit Fault 6 Comp Load Exp Ready 24 1 4 3 12 dB Headroom 2 3 REMOTE 1 REMOTE PAGE ZONE ASSIGN WIRING L INPUT 1 PAGING INPUTS PAGE 2 TRIM Z1 Z2 PAGE 1 TRIM 2 R 1&2 PRIORITY R 3 PRIORITY 3 PAGE 2 2 1 REMOTE 2 Z2 Z1 INPUT 2 + – IN1 PRIORITY 4 +60 LINE OL +30 MIC +60 LINE IN2 PRIORITY 2 PRIORITY 1 MUSIC SERVICE 4 +30 MIC PAGE 1 DETECT THRESHOLD PR 2 PAGE 1 ON 3 Limit Fault 6 Comp Load Exp Ready 12 L TO TELEPHONE MUSIC-ON-HOLD MA 4 MULTICHANNEL AMPLIFIER 1 PRIORITY ASSIGN ZONE MA 4 OFF DIGITAL AMPLIFIER 24 dB Headroom CH 68 DVR MT 4 70V TRANSFORMER Z1 Z2 BOTH PAGE 1 ASSIGN OFF Z1 Z2 BOTH PAGE 2 ASSIGN PAGE ASSIGN HOLE PLUG 10 8:58 MT 4 MULTICHANNEL TRANSFORMER CD RECEPTION STATION PR 2 ZONE 2 ZONE 2 EXPAND ZONE 1 EXPAND ZONE 1 OFF PAGE 2 Z1 Z2 BOTH PAGE 1 ASSIGN OFF DISTRIBUTED ZR 1 ZR 1 L1 L2 L3 P PROGRAM SELECT 4 6 2 8 0 DISTRIBUTED DISTRIBUTED PROGRAM SELECT PATIO DINING L1 L2 L3 P 6 2 10 8 0 LEVEL Z1 Z2 BOTH PAGE 2 ASSIGN OFFICE PAGE RESTROOMS PROGRAM SELECT 4 LEVEL DISTRIBUTED HOLE PLUG 10 PROGRAM SELECT LEVEL MIC OR TELEPHONE PAGE TELEPHONE KEY SERVICE 10 8 19:58 JUKEBOX LEVEL DINING ROOM LOUNGE OFFICES Data Sheet- CP 64S COMMERCIAL PROCESSOR Rear Panel CP 64S COMMERCIAL AUDIO EQUIPMENT 24TJ 100-240 V 50/60 Hz 12 WATTS Z2 PGM Z2 LEVEL PROGRAM INPUTS Z2 EXPAND Z2 MONO WIRING LIMITER ZONE 1 ZONE 2 MIN MAX Vr Vc R ZONE 2 EXPAND OUT ACN 001 345 482 RANE CORP. MADE IN U.S.A. OUTPUTS REMOTES Z1 PGM D1 D0 +8 ZONE 1 EXPAND OUT ZONE PAGE ZONE PAGE Z1 LEVEL 2 1 Vr Vc PGM PGM –20 Z1 EXPAND Z1 RIGHT + – + – Z1 LEFT + – +8 +20 –20 PRIORITY ASSIGN ZONE off 1 +20 THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES FOR A CLASS 'B' COMPUTING DEVICE. L REMOTE 1 REMOTE PAGE ZONE ASSIGN WIRING L INPUT 1 PAGING INPUTS PAGE 2 TRIM Z1 Z2 PAGE 1 TRIM 2 1&2 R PRIORITY R 3 2 PAGE 2 1 +30 +60 MIC LINE PAGE 1 DETECT THRESHOLD REMOTE 2 Z2 Z1 INPUT 2 + – OL +30 MIC +60 LINE Euroblocks are included, removed here for visibility. Architectural Specifications The processor shall provide two fully independent gated paging inputs, three line-level non-priority program inputs and one gated line-level priority program input. Two zone outputs shall be served. Zone 1 shall be a stereo zone with balanced, crosscoupled outputs. Zone 2 shall be a mono zone with a balanced cross-coupled output. Mono expansion ports for page, program or zone signals shall be provided for each zone. Wired remote control ports shall be provided for paging zone assign, zone program select and zone level. Page inputs shall use a 5-pin Euroblock connector. Paging controls shall include: • 30 dB mic/line input pad. • Input gain trim range of 30 dB to 60 dB. • Mic gate threshold (range -∞ to +4 dBu). • 15 volt phantom power (internal switch). • Paging priority (page 1, none, page 2; internal switch). • Pre- or post-zone level summing (internal switch). • Front panel paging zone assign (Remote, Z1, Z2, Both). • Remote paging zone assign (Off, Z1, Z2, Both). • Paging zone level. Each Program input shall have stereo RCA input jacks and independent input level control. The priority program assign switch shall provide priority program override to zone 1, zone 2, both, or neither (off). The gated priority program input shall have internally adjustable threshold and release time controls. Zone outputs shall use 3-pin Euroblock connectors. Zone controls shall include: • Ducker on/off • Ducker depth (-6 to -50 dB) • Program select (L1, L2, L3, P) • Zone level • 7-band graphic equalizer (±12 dB) • Servo-Locked-Limiter™ threshold (-20 to +20 dBu) • Mono switch for Zone 1 (internal) • Remote engage switch Wired remote ports shall use 3-pin Euroblock connectors. Remote logic shall be active low with internal pull-up. Remote level control shall be ratiometric DC control with 5 volt reference. The unit shall be capable of operation by means of its own built-in universal power supply operating at 100-240 VAC and meet CE requirements. The unit shall be UL and cUL listed. The unit shall be entirely constructed from cold-rolled steel. Reliability and efficiency are to be primary design considerations. The unit shall be a Rane Corporation CP 64S Commercial Processor. Available Accessories • • • • • SCP 2 Security Cover (for EQ section) SC 1.7 Security Cover (for entire front panel) PR 2 Page Assign Remote Control ZR 1 Zone Source/Volume Remote Control Hole Plugs (6 Provided) ©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5098 USA TEL 425-355-6000 FAX 425-347-7757 WEB www.rane.com Data Sheet- All features & specifications subject to change without notice. DOC 102906