Preview only show first 10 pages with watermark. For full document please download

Cp12200 12v 20ah(20hr)

   EMBED


Share

Transcript

CP12200 12V 20Ah(20hr) The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte is absorbed by separators and plates and thus immobilized. Should the battery be accidentally overcharged producing hydrogen and oxygen, special one-way valves allow the gases to escape thus avoiding excessive pressure build-up. Otherwise, the battery is completely sealed and is, therefore, maintenance-free, leak proof and usable in any position. Battery Construction Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte Raw material Lead dioxide Lead ABS ABS Rubber Copper Fiberglass Sulfuric acid Performance Characteristics General Features ● ● ● ● ● ● ● ● Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintenance or water adding. Not restricted for air transport-complies with IATA/ICAO Special Provision A67. UL-recognized component. Can be mounted in any orientation. Computer designed lead, calcium tin alloy grid for high power density. Long service life, float or cyclic applications. Maintenance-free operation. Low self discharge. Dimensions and Weight Length(mm / inch) Width(mm / inch) Height(mm / inch) Total Height(mm / inch) Approx. Weight(Kg / lbs) 181 / 7.13 77 / 3.03 167 / 6.57 167 / 6.57 5.9 / 13 Nominal Voltage 12V Number of cell 6 Design Life 10 years Nominal Capacity 77oF(25oC) 20 hour rate (1A, 10.5V) 20Ah 10 hour rate (1.85A, 10.5V) 18.5Ah 5 hour rate (3.45A, 10.5V) 17.25Ah 1 hour rate (13.4A, 9.6V) 13.4Ah Internal Resistance 15mOhms Fully Charged battery 77oF(25oC) Self-Discharge 3% of capacity declined per month at 20oC(average) Operating Temperature Range Discharge -20~60oC Charge -10~60oC Storage -20~60oC o o 300A(5s) Max. Discharge Current 77 F(25 C) Short Circuit Current 1000A Charge Methods: Constant Voltage Charge Cycle use Maximum charging current Temperature compensation Standby use Temperature compensation 77oF(25oC) 14.5-14.9V 8A -30mV/oC 13.6-13.8V -20mV/oC Discharge Constant Current (Amperes at 77oF25oC) End Point Volts/Cell 5min 10min 15min 30min 1h 3h 5h 10h 20h 1.60V 75.0 51.2 39.6 22.4 13.4 5.36 3.72 1.93 1.07 1.65V 73.3 49.9 38.7 22.1 13.2 5.28 3.63 1.93 1.07 1.70V 71.5 48.7 37.8 21.7 13.0 5.20 3.54 1.90 1.04 1.75V 69.7 47.4 36.9 21.4 12.8 5.11 3.45 1.85 1.00 1.80V 67.9 46.1 36.0 21.0 12.5 5.03 3.36 1.76 0.95 3h 5h Discharge Constant Power (Watts at 77oF25oC) End Point Volts/Cell 5min 10min 15min 30min 45min 1.60V 137 95 75.6 42.7 32.8 25.5 15.3 10.6 7.27 1.65V 132 93 74.3 42.1 32.4 25.2 15.2 10.5 7.18 1.70V 128 91 73.0 41.5 32.0 25.0 15.0 10.4 7.09 1.75V 123 89.4 71.8 40.9 31.6 24.7 14.8 10.3 7.00 1.80V 119 88.0 70.5 40.3 31.2 24.5 14.6 10.2 6.99 1h 2h (Note)The above characteristics data are average values obtained within three charge/discharge cycles not the mimimum values. page1 of 2 www.vision-batt.com 13.0 12V20Ah Constant voltage charging o characteristic (0.25CA,25 C) (%) (XCA) (V) 140 12.0 Voltage(v) Voltage Discharge characteristic (25 OC) Current Charged Volume CP12200 120 0.25 100 0.20 11.0 10.0 80 9.0 60 0.15 20 0.05 2 3 5 min 10 20 30 60 5 h 2 3 10 0 0 20 30 Charge Voltage 12.0 11.0 0 0 1 Charged Volume 14.0 13.0 0.10 40 8.0 15.0 Charging Current 0 2 4 6 8 10 12 14 16 18 20 Charging time (hours) Discharge time Relationship between charging voltage and temperature Self-discharge characteristic 110 100 C y c le 15.0 Capacity(%) Voltage(V) 15.6 Use 14.4 S ta n d 13.8 by Use 90 80 70 60 13.2 o o C o C C 50 -10 0 10 20 30 40 o Ambient temperature( C) 50 40 60 0 2 4 6 8 10 12 14 Storage time: months 16 18 20 Cycle service life in relation to depth of discharge Life characteristics of Standby use 120 120 100 Capacity(%) Capacity(%) 100 80 60 Testing conditions:floating voltage:2.27 to 2.30V Cell o o ambient temperature: 25 C(77 F) 80 60 40 40 20 20 1 0 2 Life(year) 0 3 30% Depth of discharge 100% D.O.D. 50% D.O.D. 200 400 600 800 1000 1200 1400 Number of cycles(cycles) Temperature effects on float life Temperature effects on capacity 10 120 Capacity (%) Life(years) 100 2.30V Cell 1 C 0 .0 5 0 .1 C C 2 . 0 80 60 1 .0 C 2 .0 C 40 3 .0 C 20 0.1 10 20 30 40 50 0 -20 60 -10 0 10 20 30 40 o Temperature( C) THE INTERNATIONAL CERTIFICATION NETWORK ISO9001:2000 MH25860 G4M19906-9202-E-16 www.vision-batt.com Shenzhen Center Power Tech. Co., Ltd. Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail: [email protected] Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2003-9) Page 2 of 2 o 50( C)