Transcript
CP628
6V 2.8Ah(20hr)
The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte is absorbed by separators and plates and thus immobilized. Should the battery be accidentally overcharged producing hydrogen and oxygen, special one-way valves allow the gases to escape thus avoiding excessive pressure build-up. Otherwise, the battery is completely sealed and is, therefore, maintenance-free, leak proof and usable in any position. Battery Construction Component
Positive plate
Negative plate
Container
Cover
Safety valve
Terminal
Separator
Electrolyte
Raw material
Lead dioxide
Lead
ABS
ABS
Rubber
Copper
Fiberglass
Sulfuric acid
Performance Characteristics
General Features ●
●
● ● ●
●
● ●
Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintenance or water adding. Not restricted for air transport-complies with IATA/ICAO Special Provision A67. UL-recognized component. Can be mounted in any orientation. Computer designed lead, calcium tin alloy grid for high power density. Long service life, float or cyclic applications. Maintenance-free operation. Low self discharge.
Dimensions and Weight Length(mm / inch) Width(mm / inch) Height(mm / inch) Total Height(mm / inch) Approx. Weight(Kg / lbs) * Weight deviation: ± 5%
66 / 2.60 33 / 1.30 97 / 3.82 104 / 4.09 0.58 / 1.28
Nominal Voltage 6V Number of cell 3 Design Life 5 years Nominal Capacity 77oF(25oC) 20 hour rate (0.14A, 5.25V) 2.8Ah 10 hour rate (0.26A, 5.25V) 2.6Ah 5 hour rate (0.45A, 5.25V) 2.25Ah 1 hour rate (1.87A, 4.8V) 1.87Ah Internal Resistance ≤ 25mOhms Fully Charged battery 77oF(25oC) Self-Discharge 3% of capacity declined per month at 20oC(average) Operating Temperature Range Discharge -20~60oC Charge -10~60oC Storage -20~60oC o o 42A(5s) Max. Discharge Current 77 F(25 C) Short Circuit Current
140A
Charge Methods: Constant Voltage Charge Cycle use Maximum charging current Temperature compensation Standby use Temperature compensation
77oF(25oC) 2.40-2.45VPC 1.12A -15mV/oC 2.23-2.30VPC -10mV/oC
Discharge Constant Current (Amperes at 77oF25oC) End Point Volts/Cell 1.60V 1.65V 1.70V 1.75V 1.80V
5min 10min 15min 30min 10.50 9.95 9.39 8.80 8.21
7.20 6.85 6.50 6.13 5.77
5.60 5.35 5.10 4.83 4.56
3.20 3.07 2.94 2.80 2.65
1h
3h
5h
10h
20h
1.87 1.80 1.73 1.65 1.58
0.75 0.73 0.70 0.67 0.64
0.49 0.48 0.46 0.45 0.43
0.28 0.27 0.27 0.26 0.25
0.15 0.14 0.14 0.14 0.14
Discharge Constant Power (Watts at 77oF25oC) End Point Volts/Cell 1.60V 1.65V 1.70V 1.75V 1.80V
5min 10min 15min 30min 45min 20.7 19.4 18.1 16.8 15.6
14.0 13.2 12.4 11.6 10.8
10.70 10.10 9.51 8.92 8.33
6.13 5.83 5.51 5.19 4.87
4.23 4.04 3.84 3.63 3.42
1h
2h
3h
5h
3.67 3.51 3.35 3.18 3.01
2.13 2.07 2.00 1.92 1.84
1.48 1.45 1.41 1.37 1.32
0.97 0.95 0.93 0.91 0.89
(Note)The above characteristics data are average values obtained within three charge/discharge cycles not the mimimum values. All data shall be changed without notice,Vision reserves the right to explain and update the information contained hereinto.
page1 of 2
www.vision-batt.com
6.5
Voltage(v)
6V2.8Ah
Constant voltage charging o characteristic (0.25CA,25 C)
(%) (XCA) (V) 140
6.0 5.5
120
0.25
100
0.20
5.0 80 4.5
0.15 0.10
40
0 1
3
2
5
20 30
10
60
5
2 3
min
10
20 30
20
0.05
0
0
h
7.5
Charged Volume
7.0
Charge Voltage
6.5
60
4.0 0
Voltage
O
Discharge characteristic (25 C)
Current
Charged Volume
CP628
6.0 5.5
Charging Current
0
2
4
6
Discharge time
8
10
12
14
16
18
20
Charging time (hours)
Relationship between charging voltage and temperature
Self-discharge characteristic 110 100
Cycl
7.5
e Us
Capacity(%)
Voltage(V)
7.8
e
7.2 S ta n d
6.9
by Use
90 80 70 60
6.6
o
o
C
o
C
C
50
-10
0
10 20 30 40 Ambient temperature( oC)
50
40
60
0
2
4
6
8 10 12 14 Storage time: months
16
18
20
Cycle service life in relation to depth of discharge
Life characteristics of Standby use 120
120 100 Capacity(%)
Capacity(%)
100
80
60
Testing conditions:floating voltage:2.27 to 2.30V Cell ambient temperature: 25 oC(77 oF)
80 60
40
40
20
20
1
0
2 Life(year)
0
3
30% Depth of discharge
100% D.O.D. 50% D.O.D.
200
Temperature effects on float life
400 600 800 1000 Number of cycles(cycles)
1200
1400
Temperature effects on capacity
10
120
Capacity (%)
Life(years)
100
2.30V Cell 1
C 0 .0 5 0 .1 C C 2 . 0
80 60
1 .0 C 2 .0 C
40
3 .0 C
20 0.1
10
20
30
40
50
0 -20
60
-10
0
10
20
30
40
Temperature( oC)
THE INTERNATIONAL CERTIFICATION NETWORK
ISO9001:2008
MH25860
G4M19906-9202-E-16
www.vision-batt.com
Shenzhen Center Power Tech. Co., Ltd. Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail:
[email protected] Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2013-4)
Page 2 of 2
50( o C)