Preview only show first 10 pages with watermark. For full document please download

Cpb Version 2.1

   EMBED


Share

Transcript

KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen-Frommern E-Mail: [email protected] GB Service Manual Electronic Counting Balance KERN CPB Software rev.: 3.02 & above Version 2.1 11/2007 Tel: 0049-[0]7433- 9933-0 Fax: 0049-[0]7433-9933-149 Internet: www.kern-sohn.com Page 2 CONTENTS 1.0 INTRODUCTION ..................................................................................................3 2.0 SPECIFICATIONS ................................................................................................4 2.0 TROUBLESHOOTING ..........................................................................................5 3.0 INSTALLATION ....................................................................................................6 3.1 3.2 4.0 GENERAL INSTALLATION ...............................................................................6 PREPARATION FOR USE ................................................................................6 SERVICE PARAMETERS.....................................................................................8 4.1 USING “0000” TO ENTER THE CALIBRATION PARAMETER..........................8 4.1.1 F1 - CALIBRATION .........................................................................................9 4.1.2 F2 - PIN FOR CALIBRATION .........................................................................9 4.2 USING “2006” TO ENTER THE SERVICE PARAMETERS .............................11 4.2.1 F1 - CALIBRATION .......................................................................................12 4.2.1 F1 - CALIBRATION .......................................................................................12 4.2.2 F2 - RESOLUTION .......................................................................................12 4.2.3 F3 - CAPACITY ............................................................................................12 4.2.4 F4 - INITIAL ZERO RANGE..........................................................................13 4.2.5 F5 - RE-ZERO RANGE ................................................................................13 4.2.6 F6 - SUCCESSIVE TARE.............................................................................13 4,2.7 F7 - A/D COUNT ...........................................................................................14 4.2.8 F8 - ZERO ....................................................................................................14 4.2.9 F9 - PIN ........................................................................................................14 4.2.10 F10 - LVD MODE ..........................................................................................15 4.3 WEIGHING UNITS [KG / G] ................................................................................15 5.0 WIRING DIAGRAM.............................................................................................16 6.0 MECHANICAL ASSEMBLY ................................................................................17 7.0 FRONT DISPLAY SCHEMATIC .........................................................................18 7.1 8.0 8.1 FRONT DISPLAY ASSEMBLY ........................................................................19 MAIN PCB SCHEMATIC.....................................................................................20 MAIN PCB ASSEMBLY..................................................................................21 CPB-SH-e-0721 2 1.0 INTRODUCTION • The CPB series of scales provide an accurate, fast and versatile counting and check-weighing scales. • CPB scales are kilogram only scales. EC type approved scales are limited to lower resolution operation, however the counting abilities still use the same internal resolution. • They all have stainless steel weighing platforms on an ABS base assembly. • All scales available with RS-232 interface and real time clock (RTC). • All scales have sealed keypad with colour coded membrane switches and there are three large, easy to read liquid crystal type displays (LCD). The LCD’s are supplied with a backlight. • The scales include automatic zero tracking, audible alarm for pre-set weights, automatic tare, pre-set tare, an accumulation facility that allows the count to be stored and recalled as an accumulated total and an bidirectional RS-232 interface for communicating with a PC or printer. CPB-SH-e-0721 3 2.0 SPECIFICATIONS Approved Series CPB-M SERIES Model # Maximum Capacity Readability Tare Range Repeatability (Std Dev) Linearity ± CPB 3K1M CPB 6K2M CPB 15K5M CPB 30K10M 3000 g 6000 g 15 kg 30 kg 1g -3000 g 1g 2g -6000 g 2g 0.005 kg (5g) -15 kg 0.005 kg (5g) 0.01 kg (10g) -30 kg 0.01 kg (10g) 2g 4g 0.01 kg (10g) 0.02 kg (20g) Non Approved Series CPB SERIES Model # Maximum Capacity Readability Tare Range Repeatability (Std Dev) Linearity ± CPB 3K0.1 CPB 6K0.2 CPB 15K0.5 CPB 30K1 3000 g 6000 g 15 kg 30 kg 0.1 g -3000 g 0.1 g 0.2 g -6000 g 0.2 g 0.5g -15 kg 0.5g 1g -30 kg 1g 0.4 g 0.8 g 1.5 g 3g Common Specifications Interface Stabilisation Time Operating Temperature Power supply Battery Calibration Display Balance Housing Pan Size Overall Dimensions (wxdxh) Net Weight Applications Functions Interface Date/Time CPB-SH-e-0721 RS-232 bi-directional interface 2 Seconds typical 0°C - 40°C 32°F - 104°F 230 VAC 50/60 Hz. 120 VAC available. Internal rechargeable battery (~50 hours operation) External Not available on EC approved units (locked) 3 x 6 digits LCD digital displays ABS Plastic, Stainless Steel platform 225 x 275mm 8.9” x 10.8” 315 x 355 x 110mm 12.4” x 14” x 4.3” 4.1 kg / 9 lb Counting Scales Parts counting, weighing, accumulating memory, pre-set count with alarm RS-232 bi-directional interface Real Time Clock (RTC), To print date and time information. (Dates in year/month/day, day/month/year or month/day/year formats Battery backed) 4 2.0 TROUBLESHOOTING 1. Unit does not turn on Check whether the scale is plugged into the power supply properly. Check the operation of the charging circuit. Check whether the battery is charged- LED should turn to green from red. Check the adapter output. . 2. The scale weighs but is unstable Air drafts or vibration or unstable table. Pan rubbing against case or not installed correctly. Scale not installed properly. Improper connections on ADC circuit. 3. Scale shows wrong weight Scale not installed correctly. Check the Calibration. To check whether a part of product weighed is trapped between the pan and the scale. Incorrect adjustment of the mechanical stops. 4. An error “E4” Load cell damage. displays on the screen Scale not installed properly. Incorrect adjustment of the mechanical stops. Factory calibration has been tampered with- check the ADC counts and re-calibrate. CPB-SH-e-0721 5 3.0 INSTALLATION 3.1 GENERAL INSTALLATION The scales should not be placed in a location that will reduce the accuracy. Avoid extremes of temperature. Do not place in direct sunlight or near air conditioning vents. Avoid unsuitable tables. The table or floor must be rigid and not vibrate. Avoid unstable power sources. Do not use near large users of electricity such as welding equipment or large motors. Do not place near vibrating machinery. Avoid high humidity that might cause condensation. Avoid direct contact with water. Do not spray or immerse the scales in water. Avoid air movement such as from fans or opening doors. Do not place near open windows or air-conditioning vents. Keep the scales clean. Do not stack material on the scales when they are not in use. 3.2 PREPARATION FOR USE The scales come with a stainless steel platform, packed separately. Place the platform in the receptacles on the top cover. Do not press with excessive force as that could damage the load cell inside. Level the scale by adjusting the four feet. The scale should be adjusted such that the bubble in the spirit level is in the centre of the level and the scale is supported by all four feet. Turn the power ON using the switch located on the right side of the base. CPB-SH-e-0721 6 The unit will display the software revision number in the Weight window and count down to zero while performing a self-test. When ready all three displays will show zero. Refer to the CPB user manual for detailed operating instructions. CPB-SH-e-0721 7 4.0 SERVICE PARAMETERS • • • • Place your balance upside down Remove seal For verified balances, the jumper is on a pin For adjustment the jumper must be set on both pins Position jumper for adjustment Position of seal Bottom of the balance 4.1 USING “0000” TO ENTER THE CALIBRATION PARAMETER After the jumper has been placed in the position shown, apply power to the scale. The display will ask for a code number, “Pn” on the Weight Display. Enter the number “0000” then press [Tare]. The display will show “F1” the calibration press [Tare] and to skip the calibration, press “CAL”. To enter . “F2” “Pin” will be displayed. NOTE: If the PIN number has been changed by other users, the correct Pin number will be required in place of 0000. CPB-SH-e-0721 8 4.1.1 F1 - CALIBRATION To enter the calibration parameter, press the [Tare] key when “F1” “CAL” is displayed. The Weight display will instruct you to remove any weight from the scale, “UnloAd” Press the [Tare] key. The displays will ask you to place the calibration weight on the scale: “LoAd” “06” “kilo6” NOTE: The CPB-M series should be calibrated with the full capacity weight. That is for CPB 6K2M, use 6 kg as calibration weight. Add the suggested calibration weight as displayed or press the key to clear the value and enter another value of weight. To add this value to the platform, wait for stability then press the [Tare] key. The display will show “SPAn” “PASS” if the calibration is OK. Or it will show “SPAn” “FAIL” if calibration could not be completed correctly. The display will show “JP On”. Remove the calibration mass. Remove the jumper and the scale will run a self-test and return to normal operation. 4.1.2 F2 - PIN FOR CALIBRATION This parameter allows changing of the PIN number to gain access to calibration. To set the PIN, press the [Tare] key when “F2” “Pin” is displayed. The display will show “Pin 1” Enter the new Pin number. Press the [Tare] key to accept. The display will show “Pin 2” Enter the new Pin number a second time. CPB-SH-e-0721 Press the [Tare] key to accept. 9 The display will show “dOnE” if the number was accepted or “FAiL” if the numbers were not the same. The scale returns to the parameter menu displaying “F2” “Pin”. Turn the power off, remove the jumper and restart the scale. The new settings are now in operation. CPB-SH-e-0721 10 4.2 USING “2006” TO ENTER THE SERVICE PARAMETERS After the jumper has been placed in the position shown, apply power to the scale. The display will ask for a code number, “Pn” on the Weight Display. Enter the number 2006 when “Pn” is displayed and then press [Tare]. The displays will show the first parameter “F1” parameters press the “CAL”. To scroll through other key. Press the [Tare] key to enter a parameter. To exit a parameter, press the key. The Weight Display window will show the parameter number and the Piece Weight window will show the word describing the function. When a parameter is entered by pressing the [Tare] key, the displays will guide you through the parameter selected and the options available. The parameters available are: F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 CAL rES CAPA init rE SCSivE Ad ZEro Pin LVd CPB-SH-e-0721 ZEro ZEro tArE Count To enter the Calibration Resolution selection, not valid for CPB-M units Select Capacity Initial Zero Range Re-Zero Range Successive Tare Enable Display the A/D counts ModE Set zero method. Set new PIN number Set low voltage detect mode 11 4.2.1 F1 - CALIBRATION To enter the calibration parameter, press the [Tare] key when “F1” is displayed. The display will instruct you to remove any weight from the scale by displaying “UnloAd” Press the [Tare] key. The display will tell you to add the calibration weight to the scale: “LoAd 1” “ “kiLo5” Add the weight shown or press the 05” key to clear the value and enter another value of weight. Wait for the stability indicator and then press the [Tare] key. The display will show “SPAn” “PASS” if the calibration is OK or it will show “SPAn” “FAIL” if calibration could not be completed correctly. The display will show “JP On”. Remove the calibration weight. Remove the jumper and the scale will run a self-test and return to normal operation. 4.2.2 F2 - RESOLUTION This function is not active on the CPB-M series. 4.2.3 F3 - CAPACITY To enter this parameter, press the [Tare] key when “F3” is shown. The display will show the current capacity in 3, 6, 15 or 30 kilograms. Press the key to change the value. Press [Tare] to accept the displayed value. NOTE: The scale must be originally built for the capacity selected. The 3kg unit uses the 5kg load cells, 6kg unit uses 10kg load cells, the 15kg unit uses 20kg load cells and the 30kg unit uses 35kg load cells. CPB-SH-e-0721 12 4.2.4 F4 - INITIAL ZERO RANGE To enter this parameter, press the [Tare] key when “F4” is shown. The display will show the current initial zero range. Press the key to change the value and press [Tare] to accept the value. NOTE: Only 10% is allowed for the CPB-M scales. 4.2.5 F5 - RE-ZERO RANGE To enter this parameter, press the [Tare] key when “F5” is shown. The display will show the current re-zero range. Press the key to change the value and press [Tare] to accept the value. NOTE: Only 2% is allowed for the CPB-M scales. 4.2.6 F6 - SUCCESSIVE TARE To enter this parameter, press the [Tare] key when “F6” is shown. The display will show if the successive tare is on or off. Press the key to change the value. Press [Tare] to accept the displayed value. NOTE: Either option is allowed for the CPB-M scales. CPB-SH-e-0721 13 4,2.7 F7 - A/D COUNT To enter this parameter, press the [Tare] key when “F7” is shown. This parameter allows you to view the A/D counts from the internal A/D converter. This can be an aid to service. Press the [Tare] key to return to the PARAMETER menu. Press the key to return to normal weighing. Typical value at zero is 30,000-90,000 (approx.) Typical value at full capacity is 500,000 (approx.) 4.2.8 F8 - ZERO The scale can be selected to use a normal method to determine zero, “Mode 1” or an alternative method “Mode 2”. For all CPB-M scales set this option to “Mode 1”. To enter this parameter, press the [Tare] key when “F8” is shown. The display will show the selected zero mode. Press the key to change the value. Press [Tare] to accept “Mode 1”. 4.2.9 F9 - PIN To change the user Pin number to gain access to the Service Parameters. To enter this parameter, press the [Tare] key when “F9” is shown. The display will show “Pin 1” Enter the new Pin number. CPB-SH-e-0721 Press the [Tare] key to accept. 14 The display will show “Pin 2” Enter the new Pin number a second time. Press the [Tare] key to accept. The display will show “dOnE” if the number was accepted or “FAiL” if the numbers were not the same. The scale returns to the parameter menu. 4.2.10 F10 - LVD MODE It stands for Low Voltage Detect mode. disabled. The Low voltage detection can be enabled or To enter this parameter, press the [Tare] key when “F10” is shown. The display will show if the LVD is “on” or “oFF”. Press the key to change the value. Press [Tare] to accept “on”. NOTE: Only “LVD” “on” is allowed for the CPB-M scales. Turn the power off, remove the jumper and restart the scale. The new settings are now in operation. 4.3 WEIGHING UNITS [kg / g] The current software of CPB was standardised to weigh in [kg]. There is a function to enable the scale to weigh in [g]. The scale has to be opened and a connecting jumper has to be fitted to “JTAG” pins 1 and 2 on the main board to enable the [g] display. NOTE: The selection between both units is not possible for the CPB-M scales. CPB-SH-e-0721 15 5.0 WIRING DIAGRAM CPB-SH-e-0721 16 6.0 MECHANICAL ASSEMBLY CPB-SH-e-0721 17 7.0 FRONT DISPLAY SCHEMATIC CPB-SH-e-0721 18 7.1 FRONT DISPLAY ASSEMBLY CPB-SH-e-0721 19 8.0 MAIN PCB SCHEMATIC CPB-SH-e-0721 20 8.1 MAIN PCB ASSEMBLY CPB-SH-e-0721 21 Discussion with the manufacturer In discussions with the manufacturer’s works the following information should be provided: • • • • • Balance type e.g. CPB 15K5M Series number e.g. WP0702716 (Label on the left side of the balance) Program number e.g. U3.06A (appears on the display when switching on the balance) As precise a description of the defect as possible Weighing results KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen-Frommern Tel.: 0049-7433-9933-0 Fax: 0049-7433-9933-149 e-mail: [email protected] URL: www.kern-sohn.com