Transcript
Product Reference
CPPG5 50Hz 1p AVR
Technical data Voltage Frequency Engine Alternator Exhaust emission Level Performance class Acoustic power LwA Acoustic pressure LpA a 7 m
(V)
dB(A) dB(A)
230 50 CP390 GA6500 EU2 G1 97 73
Mechanical structure (mm) Length (L) (mm) Width (W) (mm) Height (H) (kg) Weight (l) Fuel tank capacity Wheels and handles
Genset Image for illustration purposes only
Power ratings
681 546 550 79 25 YES
Prime
Prime
Standby
Standby
kVA
kW
kVA
kW
5
5
5,5
5,5
Fuel tank Level sensor Fuel tank capacity
Dimensions
(l)
Yes 25
Fuel consumption table PRIME Load level 25% 50% 75% 100% 110%
Aut. (h) (L/h) 2,2 2,4 2,7 -
11,3 10,2 9,4 -
NOTE: range according to the standard configuration. Note: These drawings are provided for illustration purposes only.
Engine General Engine Brand Engine Model R.P.M. Power (C.V.) Fuel No. of cylinders Displacement Bore (mm) Stroke (mm) Compression ratio Regulation type Exhaust emission Level TA-Luft complient
Cooling System CP CP390 3000 13 Petrol 1 389 88 64 8.0:1 Mechanic EU2 TA-Luft0
Lubrication System Oil capacity Engine Oil Guard
1,1 Yes
Air
Cooling type
Starting system YES YES
Recoil Electric 12V
Alternator Alternator brand Alternator Model Peak power 163°/27° Poles Excitation system Performance at 100% p.f. 0.8 (%)
CP GA6500 5 2 AVR 80,5
Air intake system Air filter
Light dutty CPPG5 50Hz 1p AVR2014EN1.3
Please, contact your local Atlas Copco Dealer for more information and visit us at www.gesan.com
1/2
Electric panel Electric panel with sockets IP44, circuit breaker, running hours meter and ON-off green lamp. ■ Socket Schuko 16 A IP 44, 230 V ■ Socket 32 A, 230 V CE 2P+G 32A IP44
2 1
SCOPE OF SUPPLY: ■ Engine/alternator assembly mounted on steel frame with anti-vibration pads. ■ Red lamp for low oil level alarm. ■ Alternator voltage controlled by AVR ■ Electric start sets are supplied with battery and complementary recoil start. ■ CPPG5 and CPPG5T equipped with wheels and handles. ■ High capacity fuel tank with fuel level sensor
Regulations: The generator set has a CE Marking that includes the following directives: ■ 2006/42/CE Machine Safety. ■ 2006/95/CEE Low Voltage. ■ 2004/108/CE Electromagnetic compatibility. ■ 97/68/CE Gases and contaminating particles emissions. ■ 2005/88/CE Noise emission in the environment by equipment for use outdoors.
Definitions Prime Rating PRIME POWER: Electrical power data available at a variable load without limits of hours per year. An overload of 10 % is allowed for 1 hour of every 12. In accordance with ISO 8528/1 (2005) – PRP
Standby STANDBY POWER: Electrical power data at variable load in an emergency in accordance with standard ISO 8528/1 (2005) – ESP. Overloads of emergency power are not allowed.
Standard reference conditions 25 ºC, 100 kPa and 30% relative humidity Grupos Electrógenos Europa, S.A. is a certified company with ISO 9001, ISO 14001, OHSAS 18001 and PECAL Atlas Copco reserves the right to modify any characteristic of their equipment without prior warning. All products are designed and engineered in Zaragoza Competence Center Weight and dimensions of a standard generator set. Non-contractual document
Chicago Pneumatic, S.A. Factory: Polígono pitarco II - Parcela 20 50450 Muel (Zaragoza) España Tel.: +34 976 145 432 Fax.: +34 976 145 431
DISTRIBUTED BY:
CPPG5 50Hz 1p AVR2014EN1.3
2/2