Preview only show first 10 pages with watermark. For full document please download

Cr Relays Cr Features Twin Power Silent

   EMBED


Share

Transcript

CR Discontinued as of November 30, 2010 TWIN POWER SILENT AUTOMOTIVE RELAY CR RELAYS FEATURES 24.6 .969 • Silent Noise has been reduced by approximately 20 dB, using our own silencing design. • Twin (1 Form C × 2) Forward/reverse motor control is possible with a single relay. 17.0 .669 18.5 .728 • Sealed construction • Simple footprint enable ease of PC board layout Common Coil Coil mm inch Normally Open Product is discontinued. Normally Closed SPECIFICATIONS Contact 1 Form C × 2 Arrangement Contact material Ag alloy (Cadmium free) Initial contact resistance (Initial) (By voltage drop 6 V DC 1A) Typ. 6 mΩ (N.O.) Typ. 9 mΩ (N.C.) Contact voltage drop Rating Max. 0.2V (at 10 A) Nominal switching capacity N.O.: 20 A 14 V DC N.C.: 10 A 14 V DC Max. carrying current 35 A for 2 minutes, 25 A for 1 hour (12 V, at 20°C68°F) 30 A for 2 minutes, 20 A for 1 hour (12 V, at 85°C185°F) Min. switching capacity#1 Electrical Characteristics Max. operating speed (at nominal switching capacity) 6 cpm Min. 100 MΩ (at 500 V DC) Initial insulation resistance*4 Initial breakdown voltage*5 Between open contacts 500 Vrms for 1 min. Between contacts and coil 500 Vrms for 1 min. Operate time* (at nominal voltage)(at 20°C68°F) Max. 10 ms (initial) Release time*6 (at nominal voltage)(at 20°C68°F) Max. 10 ms (initial) 6 1 A 12 V DC Shock resistance Mechanical (at 120 cpm) Expected life (min. operations) #1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. Functional*7 Min. 100 m/s2 {10G} Destructive*8 Min. 1,000 m/s2 {100G} Functional*9 10 Hz to 100 Hz, Min. 44.1 m/s2 {4.5G} Destructive*10 10 Hz to 500 Hz, Min. 44.1 m/s2 {4.5G} Min. 107 Resistive load Min. 105*1 Vibration resistance Min. 2×105*2 Motor load Min. 105*3 Coil Nominal operating power Conditions for operation, transport and storage*11 (Not freezing and condensing at low temperature) 640 mW Ambient temperature Humidity Mass –40°C to +85°C –40°F to +185°F 5% R.H. to 85% R.H. Approx. 12.5g.44 oz Remarks TYPICAL APPLICATIONS • Power windows • Auto door lock • Electrically powered sunroof • Electrically powered mirror, etc. ORDERING INFORMATION Ex. CR 2 − 12 V Contact arrangement Coil voltage(DC) 1 Form C × 2 12 V Standard packing: Carton(tube package) 32pcs. Case: 800pcs. 1 ds_61209_en_cr: 300108J CR Discontinued as of November 30, 2010 TYPES AND COIL DATA (at 20°C 68°F) Part No. Nominal voltage, V DC Pick-up voltage, V DC (Initial)* Drop-out voltage, V DC (Initial) Coil resistance, Ω Nominal operating current, mA Nominal operating power, mW Usable voltage range, V DC CR2-12V 12 Max. 7.2 Min. 1.0 225±10% 53.3±10% 640 10 to 16 * Other pick-up voltage types are also available. Please contact us for details. DIMENSIONS mm inch 17.0 .669 24.6 .969 PC board pattern (Bottom view) 7-1.5 +0.1 0 dia 7-.059 +.004 0 dia 4.5 .177 18.5 .728 Max. 1.0 .039 0.6 .024 3.5 .138 7-0.25 .010 4.5 177 A* Pre-soldering 4.5 .177 4.5 .177 3.5 .138 8.0 .315 4.5 .177 7-1.2 .047 22.4 .882 Tolerance: ±0.1 ±.004 Schematic (Bottom view) 3.5 .138 8.0 .315 4.5 .177 22.4 .882 COM1 Dimension: Max. 1mm .039 inch: 1 to 3mm .039 to .118 inch: Min. 3mm .118 inch: Tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 COM2 COIL NO NC * Dimensions (thickness and width) of terminal specified in this catalog is measured before pre-soldering. Intervals between terminals is measured at A surface level. EXAMPLE OF CIRCUIT Forward/reverse control circuits of DC motor for power window M COM COM Tr1 Tr2 NC NO 12 VDC ds_61209_en_cr: 300108J M Power window motor Tr1 Tr2 OFF OFF Motor Stop ON OFF Forward OFF ON Reverse 2 CR Discontinued as of November 30, 2010 REFERENCE DATA 1-(1). Coil temperature rise (at room temperature) 1-(2). Coil temperature rise (at 85°C 185°F) Sample: CR2-12V, 5pcs Contact carrying current: 10A, 15A Ambient temperature: 85°C 185°F Sample: CR2-12V, 5pcs Contact carrying current: 10A, 15A, 20A Ambient temperature: Room temperature 120 15A 10A 80 40 160 120 15A 80 10A 3. Ambient temperature and operating temperature range 12 20 0 10 20 30 40 Switching current, A 50 5. Distribution of pick-up and drop-out voltage Sample: CR2-12V, 100pcs Ratio against the rated voltage, %V 35 30 25 20 15 10 80 70 Pick-up voltage upper limit 70 Pick-up voltage (Cold start) 0 20 40 60 8085 100 120 Ambient temperature, °C 60 50 40 30 0 80 20 40 60 Ambient temperature, °C 7. Distribution of release time Sample: CR2-12V, 100pcs * With diode 100 100 90 90 80 80 70 70 Quantity, n 30 10 0 −40 −20 100 0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 Voltage, V 60 50 40 40 30 30 20 20 10 10 0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 40 Pick-up voltage lower limit Sample: CR2-12V, 100pcs 50 50 20 20 6. Distribution of operate time 60 Pick-up voltage Drop-out voltage 60 10 0 −40 −20 30 14 16 Coil applied voltage, V 4. Ambient temperature characteristics 40 5 40 0 0 14 16 Coil applied voltage, V Frequency, n 12 50 10 40 0 Coil applied voltage, VDC Switching voltage, VDC 20A Temperature rise, °C Temperature rise, °C 160 (N.O. side Room temperature) 60 200 200 Quantity, n 2. Max. switching capability (Resistive load, initial) 0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 Time, ms Time, ms 8-(2). Operation noise distribution Measuring conditions When operated When released Sample: CR2-12 V, 50 pcs. Equipment setting: “A” weighted, Fast, Max. hold Coil voltage: 12V DC Coil connection device: Diode Background noise: Approx. 20dB 50 50 40 40 Frequency Frequency 8-(1). Operation noise distribution 30 20 20 10 10 0 40 42 44 46 48 50 52 Noise level, dB 3 54 56 Microphone 30 0 36 Relay 50mm 1.969inch Sponge 38 40 42 44 46 48 50 52 Noise level, dB ds_61209_en_cr: 300108J CR Discontinued as of November 30, 2010 Change of pick-up and drop-out voltage Circuit 14VDC M Change of contact resistance 50 10 Pick-up and drop-out voltage, V Sample: CR2-12V, 3pcs Load: Inrush current: 25A, Steady current: 6A, Brake current: 15A, power window motor actual load (free condition) Tested voltage: 14V DC Ambient temperature: Room temperature N.C. side N.O. side 9 8 Pick-up voltage 7 Max. X Min. 6 5 4 Drop-out voltage Max. X Min. 3 2 Contact resistance, mΩ 9-(1). Electrical life test (Motor free) 40 30 20 Max. X(N.C.) Max. X(N.O.) Min. Min. 10 1 0 0 10 0 20 No. of operations, × 10 0 10 No. of operations, × 104 4 Load current waveform Inrush current: 25A, Steady current: 6A, Brake current: 15A Tested voltage: 14V DC 10A 100ms Change of pick-up and drop-out voltage Circuit 14VDC M Change of contact resistance 10 Pick-up and drop-out voltage, V Sample: CR2-12V, 3pcs Brake current: 22A, power window motor actual load (lock condition) Tested voltage: 14V DC Switching frequency: (ON:OFF = 0.5s:9.5s) Ambient temperature: Room temperature 50 N.C. side N.O. side 9 8 Pick-up voltage 7 6 5 Drop-out voltage 4 Max. X Min. Max. X Min. 3 2 Contact resistance, mΩ 9-(2). Electrical life test (Motor lock) 40 30 20 10 1 Motor 0 0 5 10 No. of operations, × 104 0 0 5 Max. X Max. Min. X Min. 10 No. of operations, × 104 Load current waveform Brake current: 22A Tested voltage: 14V DC 5A 100ms For Cautions for Use, see Relay Technical Information. ds_61209_en_cr: 300108J 4