Transcript
KBP201G - KBP207G
CREAT BY ART
Pb
Single Phase 2.0AMPS. Glass Passivated Bridge Rectifiers KBP
RoHS COMPLIANCE
Features
UL Recoganized File #E-326243
Glass passivated junction
Ideal for printed circuit board
Reliable low cost construction technique results in inewxpensive product
High temperature soldering guaranteed: 260℃/10 seconds at 5 lbs.,(2.3kg) tension
Small size, simple installation
Green compound with suffix "G" on packing code & prefix "G" on datecode
Mechanical Data
Case: Molded plastic body
Terminal: Leads solderable per MIL-STD-202 Method 208
Weight: 1.52 grams
Dimensions in inches and (millimeters) Marking Diagram KBP20XG
= Specific Device Code
G
= Green Compound
Y
= Year
WW
= Work Week
Maximum Ratings and Electrical Characteristics Rating at 25 ℃ ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%
Maximum Repetitive Peak Reverse Voltage
VRRM
KBP 201G 50
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
V
Maximum DC Blocking Voltage
VDC
50
100
200
400
600
800
1000
V
Maximum Average Forward Rectified Current @TA=50℃
IF(AV)
2
A
Peak Forward Surge Current, 8.3 ms Single Half Sinewave Superimposed on Rated Load (JEDEC method)
IFSM
60
A
Rating of fusing ( t<8.35ms)
I2T
15
A2S
Maximum Instantaneous Forward Voltage (Note 1) @2A
VF
1.2
V
IR
10 500
uA
RθjA RθjL
25 8
TJ
- 55 to + 150
O
TSTG
- 55 to + 150
O
Type Number
Maximum DC Reverse Current at Rated DC Block Voltage
Symbol
@TA=25℃ @TA=125 ℃
Typical Thermal Resistance Operating Temperature Range Storage Temperature Range
KBP 202G 100
KBP 203G 200
KBP 204G 400
KBP 205G 600
KBP 206G 800
KBP 207G 1000
Unit V
O
C/W C C
Note 1 : Pulse Test with PW=300 usec, 1% Duty Cycle
Version:D11
RATINGS AND CHARACTERISTIC CURVES (KBP201G THRU KBP207G)
FIG. 2 TYPICAL REVERSE CHARACTERISTICS PER BRIDGE ELEMENT
FIG.1 FORWARD CURRENT DERATING CURVE 100
2 1.5 1 0.5 0 0
20
40 60 80 100 120 AMBIENT TEMPERATURE (oC)
140
160
INSTANTANEOUS REVERSE CURRENT (uA)
AVERAGE FORWARD A CURRENT (A)
2.5
TA=125℃ 10
1 TA=25℃
0.1 0
FIG. 3 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT PER BRIDGE ELEMENT
20
40
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE (%)
60 PEAK FORWARD SURGE A CURRENT (A)
50 40
FIG. 4 TYPICAL JUNCTION CAPACITANCE 1000
30
10 0 1
10 NUMBER OF CYCLES AT 60 Hz
100
FIG. 5 TYPICAL FORWARD CHARACTERISRICS PER BRIDGE ELEMENT
CAPACITANCE (pF) A
20 TA=25℃
100
10
10
0.1
1
10
100
1000
INSTANTANEOUS FORWARD A CURRENT (A)
REVERSE VOLTAGE (V)
1
0.1 TA=25℃ PULSE WIDTH 300uS 1% DUTY CYCLE
0.01 0.6
0.7
0.8 0.9 1 1.1 FORWARD VOLTAGE (V)
1.2
1.3
1.4
Version:D11