Cropico D07e Specifications

   EMBED


Share

Transcript

RESISTANCE MEASURING INSTRUMENTS D07E RUGGED DIGITAL MICRO OHMMETER FOR LOW RESISTANCE MEASUREMENT The DO7e is a very rugged yet compact and portable digital key feature micro ohmmeter for the measurement of low resistance. Using a True 4 wire measurement eliminates lead resistance ■ 6 push button ranges 6 milli ohm to 600 ohm ■ rechargeable sealed lead acid battery with built-in charger, DO7E Resolution 1 micro ohm on 6 milli ohm range ■ the DO7e is capable of measuring with a current of 10 Amps on Auto ranging ■ the lowest range. The DO7e has been designed with the latest 10 Amp measuring current on lowest range ■ 0.8'' LED Display daylight viewable ■ solid state and microprocessor techniques to ensure the very Input protection up to 415 Volts rms ■ best in measurement, reliability and features. Automatic range Forward and reverse current measurement ■ selection, forward and reverse current measurements with auto Auto average of forward and reverse measurement ■ Auto power off ■ Mains / rechargeable battery operation ■ Digital calibration pass code protected ■ average and a remote start socket are all included as well as an energy saving power down mode. Bracken Hill, South West Industrial Estate, Peterlee, County Durham, SR8 2SW United Kingdom Tel: +44 (0) 191 586 3511 Fax: +44 (0) 191 586 0227 Email: [email protected] Web: www.cropico.com D07E SPECIFICATIONS Range Resolution Typical Current Accuracy at 20°C ±5°C, 1 Year Temp Coefficient/°C 600Ω 100mΩ 1mA ±(0.25% Rdg +0.05% FS) 40ppm Rdg + 30ppm FS 60Ω 10mΩ 10mA ±(0.25% Rdg +0.05% FS) 40ppm Rdg + 30ppm FS 6Ω 1mΩ 100mA ±(0.25% Rdg +0.05% FS) 40ppm Rdg + 30ppm FS 600mΩ 100µΩ 1A ±(0.25% Rdg +0.05% FS) 40ppm Rdg + 30ppm FS 60mΩ 10µΩ 1A ±(0.25% Rdg +0.05% FS) 40ppm Rdg + 30ppm FS 6mΩ 1µΩ 10A ±(0.25% Rdg +0.05% FS) 40ppm Rdg + 250ppm FS Measurement Dimensions 4 Terminal Kelvin / Thomson principle eliminates errors due to lead resistance. Open circuit measurement voltage = 2V dc 343mm x 327mm x 152mm (W D H) approx Mass Display 6kg approx 0.8” LED 6000 count with automatic decimal point and polarity indication Protection 415 Vrms maximum at input terminals Ranges Calibration 6 push button selected with LED indication Digital Pass code protected Terminals Binding posts accept 4mm spade tags, 6mm bare wires and 4mm banana plugs (4mm safety sockets) Working Temperature Battery Sealed lead acid battery with built-in charger. Greater than 1000 measurements on lowest (10A range) and 20 hours on other ranges from a fully charged battery 0°C to 40°C rel. humidity 80% max. non-condensing Average Storage Temperature Automatic average and display of measurement with forward and reverse current -20 to +50°C Mains Supply 115/230 Volts +10%-10% 47 to 63Hz 20VA Safety EN 61010-1 EMC - EN 61236 D07e Options Code Item CB03 Lead bag attaches to lid of DO7e must be ordered with DO7e D07-RS Remote start plug FS01 Remote start foot switch HS01 Duplex handspikes with 3 metre lead length HS01-RS Duplex handspikes with 3 metre lead length with remote start button suitable for DO7 and DO7e HS02 Duplex handspikes with 3 and 15 metre lead length HS02-RS Duplex handspikes with 3 and 15 metre lead length with remote start button LS03 Lead set with 3 metre leads terminated in large Kelvin clips type KC3 LS04 Lead set with 3 metres and 15 metres lead length terminated in large Kelvin clips type KC3 MTS2 Calibration standard Seaward test and measurement companies include: SEAWARD CLARE CROPICO RIGEL SEAWARD G R O U P INDUSTRIAL SAFETY INSTRUMENTS PRECISION INSTRUMENTS MEDICAL PORTABLE ELECTRICAL SAFETY INSTRUMENTS