OUR SATISFIED CUSTOMERS
CRUZE THROUGH A POWER CUT AT BEDTIME U N I N T E R R U P T E D
P O W E R
S U P P L Y
Automatically switches on during power cuts
and many more..
Note: These companies and brand logos are used herein for identification purposes only and may be the trademarks of their respective owners.
No of Batteries
Float - Boost, CVCC Type SMF / Flat / Tubular 15 15
6
15
5A / 7A / 10A (Selectable) Batteries Dependent 45 Deg C 95% RH - Humidity
Dimensions -W x H x D Weight Class Ventilation
55 DB 320 x 625 x 530 77.5kg
82kg
89.6kg
IP20 Forced Air Cooled Reverse Battery Input Phase Reversal Mains Low / High Cut Dc Low Voltage Dc Over Voltage Short Circuit Protection Dead Short Circuit Protection High Temperature Mains Input Breaker, Battery Breaker, Electronic Protection, Fast Acting HRC Fuse in IGBT Circuit at the Ouput of UPS
LCD Display + LED LED Indication INDICATIONS LCD Indication
MONOCHROME ALPHANUMERIC LCD + 5 LED'S BATTERY CHG. / CHARGED UPS ON OVERLOAD / SHORT CIRCUIT BATTERY LOW PHASE REVERSAL System Capacity, Input Voltage, Output Voltage, Frequency, Battery Voltage, Battery
UPS On Manual Bypass LCD Display Parameters Scroll / Hold Input Window Selection (Narrow / Medium / Wide)
User Selection Switches
Battery Type Selection (SMF / Fat / Tubular) Charging Current Selection (Low / Medium / High)
Output Voltage Selection 220V / 230V Mains To UPS Changeover Selection Low/High
3 PHASE LIFT UPS SPECIFICATIONS ( LIFT PRO) Contents Technology Rating
Parameters
6KVA / 72VDC
Topology System Rating
6KVA / 72V DC
7.5KVA / 180V DC
10KVA / 180V DC
0.7 3P + N + E (3 PHASE, 4 WIRES + EARTH) 400/380V Phase-Phase (230/220V P-N) on Battery
Output Voltage Setting Output Voltage Regulation On Battery
+/-2%
Output Frequency on Battery
50 Hz ± 0.5 Hz
Output Voltage In Mains Mode
Same As Input
Output Frequency In Mains Mode
Same As Input
THD (Resistive Load)
<3% <3% <7%
THD (Inductive Load) THD (Non-Linear Load) Overload
Efficiency Transfer Time Transient Response Recovery Time O/P Voltage Regulation On 100% Unbalanced Load
>=86% UPS
110% FOR 5 MIN 150% FOR 15 SEC 200% FOR 7 SEC 300% FOR 3 SEC >=88% UPS Mode > 98% in Mains Mode ( Excluding Charging) > 95% in Mains Mode (Including Charging) Mains to UPS 1 sec / 5 sec (User Selectable) UPS to Mains, No Break < 2msec ± 5%
< 60mSEC TO ± 5% OF NOMINAL VOLTAGE + 5%
Short Circuit Protection
YES
Crest Factor
3:1
Nominal Input Voltage
Input
10KVA / 180VDC
Voltage Range PF DG Control From UPS Current Distortion
15KVA / 180VDC
DSP CONTROLLED, IGBT BASED, WITH TRANSFORMER
PF Configuration
Output
7.5KVA / 180VDC
415V, 3PHASE + NEUTRAL 150-280V / 180-270V / 190-260V (SINGLE PHASE ) 260- 485V /312-468V /329-450V (THREE PHASE) 0.85 TO 0.92 OPTIONAL <15% - CHARGER MODE
15KVA / 180V DC
CONTENTS Environment ENVIRONMENT Dimensions IP Protection Ventilation
PARAMETERS
7.5KVA / 180VDC
Ambient Temperature Humidity Noise Level Dimensions -W X H X D Weight (Kg) Class Ventilation
Protection
Display
5KVA / 72VDC
LCD Display + LED
320 X 625 X 530 75
320 X 625 X 530 77.5
10KVA / 180VDC
15KVA / 240VDC
20KVA / 360VDC
400 X 755 X 680 125
400 X 755 X 680 130
45 Deg C 95% RH-Humidity < 55 DB 320 X 625 X 530 89.6
IP20 Forced Air Cooled Reverse Battery Input Phase Reversal Mains Low / High Cut Dc Low Voltage Dc Over Voltage Short Circuit Protection High Temperature Mains Input Breaker, Battery Breaker, Electronic Protection, Fast Acting HRC Fuse in IGBT Circuit of UPS Block Monochrome Alphanumeric LCD + 5 LED's Battery Chg. / Charged UPS On
LED Indication
Indications
Overload / Short Circuit Battery Low Phase Reversal
LCD Indication
System Capacity, Input Voltage, Output Voltage, Frequency, Battery Voltage, Battery Type, System Settings UPS On Manual ByPass LCD Display Parameters Scroll / Hold
Selection Switches
Input Window Selection (Narrow / Medium / Wide) User Selection Switches
Battery Type Selection (SMF / Flat / Tubular) Charging Current Selection (Low / Medium / High) Output Voltage Selection 220V / 230V Mains to UPS Changeover Selection Low/High
3-PHASE INDUSTRIAL UPS SPECIFICATIONS (PRO) CONTENTS
PARAMETERS
Technology
Topology
Rating
System Rating
5KVA / 72VDC
7.5KVA / 180VDC
10KVA / 180VDC
5KVA / 72V DC
7.5KVA / 180V DC
Output Voltage Setting
10KVA / 180V DC 15KVA / 240V DC 0.8 3P + N + E (3 PHASE, 4 WIRES + EARTH) +/-2%
Output Frequency on Battery
50 Hz ± 0.5 Hz
Output Voltage in Mains Mode
Same As Input
Output Frequency in Mains Mode
Same As Input
THD (Resistive Load) THD (Inductive Load) THD (Non-Linear Load)
<3% <3% <7% 110% for 5 Min 150% for 15 Sec 200% for 7 Sec 300% for 3 Sec >=88% UPS Mode > 98% in Mains Mode (Excluding Charging) > 95% in Mains Mode (Including Charging) Mains to UPS 300msec UPS to Mains, No Break < 2msec ± 5% < 60msec to ± 5% of Nominal Voltage
Overload
Efficiency Transfer Time Transient Response Recovery Time O/p Voltage Regulation on 100% Unbalanced Load
+ 5%
Short Circuit Protection Crest Factor Nominal Input Voltage
Battery Charger
YES 3:1 415V, 3PHASE + NEUTRAL 150-280V / 180-270V / 190-260V (SINGLE PHASE )
Voltage Range PF Type Battery Selection No of Batteries Charging Current Even at Lowest Range Back Up Time
20KVA / 360V DC
400/380V Phase-Phase (230/220V P-N) on Battery
Output Voltage Regulation On Battery
Input
20KVA / 360VDC
DSP CONTROLLED, IGBT BASED, WITH TRANSFORMER
PF Configuration
Output
15KVA / 240VDC
6
15
260- 485V /312-468V /329-450V (THREE PHASE)
0.85 TO 0.92 FLOAT - BOOST, CVCC TYPE SMF / FLAT / TUBULAR 15 5A / 10A / 15A (Selectable) Batteries Dependent
20
30
User Interface
Category Power Rating
V a r i a n t s
Indications
Cruze+ 2KVA (24V - 2 Battery)
Audible Alarms
Cruze+ 2.5KVA (36V - 3 Battery)
Cruze+ 3.5KVA
Protections
(48V - 4 Battery)
Cruze+ 4KVA
Environmental
(48V - 4 Battery)
Cruze 5.2KVA (72V - 6 Battery)
Cruze 5.5KVA (96V - 8 Battery)
Cruze 7.5KVA (120V - 10 Battery)
Cruze 10KVA (180V - 15 Battery)
As per typical usage. For light loads, we recommend that the capacity of the UPS to be 1.3 times the rated power of connected loads. For heavy loads, we recommend the capacity of the UPS to be 3 times the rated power of connected loads. Kindly check the rated power consumption of your appliances before selecting the UPS.
Physical
Requirement Input & Output Connection on Rear Panel UPS On Battery Low Mains On Smart Charge/ Boost Charging Battery Charged/ Float Charge Overload Over Temperature Protection Short Circuit Under Battery Mode MCB Trip/ Short Circuit in Mains Mode Low Battery Pre-Alarm Low Battery Overload No Load Shutdown Short Circuit Mains Fail/ UPS On Over Load Mains Mode Over Load On Battery Short Circuit Over Temperature Battery Reverse Polarity Low Battery Ambient Operating Temperature Storage Temperature Humidity Cooling System
Net Weight (Kg) Gross Weight ( Kg) Dimension ( Length x Width x Height ) (mm) Display Type Enclosure
5500VA
6000VA
Specifications 7500VA
10000VA
60A Terminal Block
59.2 75.2
SWITCH ON UPS ON TRIP BATTERY LOW SWITCH ON MAINS ON BATT CHARGING BATTERY CHARGED TRIP OVERLOAD THERMAL SHUTDOWN SHORT CIRCUIT INPUT MCB TRIP One Beep Every 10 Sec Continuous Beep for 10 Sec Continuous Beep for 10 Sec Continuous Beep for 10 Sec Continuous Beep for 10 Sec 5 Beeps in 2 Secs 50A AC MCB 63A AC MCB > 110 % ( 5 Times Auto Retry in Unregulated UPS Mode / No Retry in Regulated UPS Mode) YES YES YES YES 0-45 Deg C 0-45 Deg C 95 % RH Non-Condensing Fan 63.2 64 91.85 79.2 80 123.8 588 x 341 x 347 600 x 350 x 360 625 x 345 x 510 LCD Display Metal / Metal with Front Panel
Category Power Rating Input
Voltage
Requirement Input Voltage Mains Mode (Regulated UPS Mode) Mains Mode ( Unregulated UPS Mode) Frequency Input Protection
5500VA
Specifications 7500VA
6000VA
10000VA
180 to 260 V AC
50A MCB
Lower Cut Off Voltage/ Restoration Voltage -( UnRegulated UPS Mode ) Upper Cut Off Voltage / Restoration Voltage -(UnRegulated UPS Mode ) Lower Cut Off Voltage/ Restoration Voltage (Regulated UPS Mode) Upper Cut Off Voltage/ Restoration Voltage -(Regulated UPS Mode )
140 to 280 V AC 40 to 60 Hz Sine Wave
63A MCB
O U T PU T C A P A C I T Y
140 V AC / 150 V AC
2KVA
2.5KVA
3.5KVA
24V
36V
48V
Input Voltage Range
100-285V
100-285V
Bulb Load (Max)
1680 Watt
5.2KVA
5.5KVA
7.5KVA
10KVA
48V
72V
96V
120V
180V
100-285V
100-285V
140-280V
140-280V
140-280V
140-280V
2100 Watt
2940 Watt
3360 Watt
4000 Watt
4200 Watt
6000 Watt
8000 Watt
21A
21A
21A
21A
21A
12A
12A
12A
Gross Weight ( In Kg)
22.25
23
31.9
31.9
44.5
72.5
80
123.8
Dimensions ( In Cm)
28x30.5x28
28*30.5*38
28*30.5*38
28*30.5*38
28x36.5x28
58.8x34.1x34.7
60x35x36
62.5x34.5x51
285V AC / 270 V AC
4KVA
180 V AC / 185 V AC
Nominal Battery Voltage
260 V AC / 255 V AC
On Battery :
Output
On Battery No Load & at Nominal Battery Voltage Mains Mode:
Power Frequency THD Change Over Time
Charger
User Interface
230V +/- 2%
Apparent Power
5500VA @ 230V
6000VA @ 230V
Bulb Load (Max)
4200 Watts
4800 Watts
On Battery :
Frequency ( on Mains Mode) Frequency ( on Batt Mode) THD % (on Battery, Linear/Resistive Load) Transfer Time (Mains to UPS Mode) Retransfer Time ( UPS to Mains Mode) Charger Current Battery System ( Nominal Voltage) No. of Batteries Charging Profile Charging Time Battery Capacity Type of Battery On/Off Switch on Front Panel By Pass Switch External 180-260 / 140-280V Operation Selection Switch On External Rear Panel High / Medium/Low Charge Selection Switch On External Rear Panel Battery Type Selection Switch On External Rear Panel AC Miniature Circuit Breaker For Mains Mode On Rear Panel DC Miniature Circuit Breaker For Battery Mode On Rear Panel DC Miniature Circuit Breaker For Battery Mode On Rear Panel
96 V DC 8
120 V DC 10
7500VA @ 230V
10000VA @ 230V
6000 Watts
8000 Watts
40 to 60 Hz 50 Hz +/- 0.5Hz <= 5% < 20 ms < 20 ms 5A/8A/12A
120 V DC 10 Adaptive Battery Charging System 10 -12 hrs Typical 120Ah-150Ah Flat/Tubular Yes Yes Yes No/ Internal No/ Internal Yes Yes ( 63A DC MCB) Yes ( 63A DC MCB)
Charging Current (Max) 180 V DC 15
Parameter
Category Power Rating
User Interface
2000VA
2500VA
180-260V AC / 100-285V AC Operation Selection Switch on External Rear Panel
Yes
High/Medium/Low Charge Selection Switch on External Rear Panel
Yes
Battery Type Selection Switch on External Rear Panel
Yes
AC Miniature Circuit Breaker for Mains Mode on Rear Panel
Yes
DC Miniature Circuit Breaker For Battery Mode on Rear Panel
No
No
Yes ( 63A DC)
UPS , "On" UPS, " Lo"
Battery Low
MAINS ON, "AC"
Mains On Smart Charge/ Boost Charging
MAINS ON, SMART CHG, "CH"
Battery Charged/ Float Charge
MAINS ON, BATTERY CHARGED, " 99%" UPS, " OL"
Overload
"nL"
No Load Shutdown
UPS , "th"
Over Temperature Protection
"UPS" Blinking, "OL" Blinking
Short Circuit Under Battery Mode
MAINS ON , " bt"
MCB Trip/ Short Circuit in Mains Mode
One Beep Every 10 sec
Low Battery Pre-Alarm Low Battery
Continuous Beep for 10 sec
Overload
Continuous Beep for 10 sec
No Load Shutdown
Continuous Beep for 10 sec
BUSINESS NEVER STOPS DURING POWER CUTS
MOVEMENT NEVER STOPS DURING POWER CUTS Continuous Beep for 10 sec
Short Circuit
5 Beeps in 2 secs
Mains Fail/ UPS On
Over Load Mains Mode Over Load on Battery
16A AC MCB 16A AC MCB 32A AC MCB > 110 % ( 5 Times Auto Retry in Unregulated UPS Mode / No Retry in Regulated UPS Mode) YES
Over Temperature
YES
Battery Reverse Polarity
H E A V Y
D U T Y
L O W
U S A G E
Capable of running extremely heavy loads on a 3 Phase Power supply
R U N N I N G
H I G H
C O S T
Humidity
Enclosure
R E L I A B I L I T Y
Less than 55dBA ( at 1m)
Audible Noise
Display Type
A N D
DC Fan
Cooling System
Physical
E F F I C I E N C Y
0-45 design Deg C uses less components Unique DSP 95 % RH Non-Condensing allowing faster feedback and precise action
Storage Temperature
Less expensive to run than any generator of similar rating Environmental
Dimension ( Length x Width x Height ) (mm)
YES
0-45 Deg C
Ambient Operating Temperature
Net Weight (Kg)
40A AC MCB
YES
Short Circuit
Low Battery
Yes ( 63A DC)
30A - 4 Way Terminal Block
UPS On
Protections
5200VA
Internal on PCBA
Battery Fuse
Audible Alarms
4000VA
20A - 4 Way Terminal Block
Input & Output Connection on Rear Panel
Indications
Specifications 3500VA
22.25
23 280 X 305 X 380
31.9 280 x 305 x 380 LED & 7-Segment Display / LCD Display Metal/ Metal with Plastic Front Panel
44.5 280 x 365 x 380
Parameter
Category Power Rating
Input
2000VA
2500VA
Specifications 3500VA
Input Voltage Mains Mode (Regulated UPS Mode)
180 to 260 V AC
Mains Mode ( Unregulated UPS Mode)
100 to 285 V AC
5200VA
40 to 60 Hz
Frequency
If life never stops during a power cut, why should your equipments? Input Protection
4000VA
16A MCB
16A MCB
32A MCB
40A MCB
MOV
Input Surge Protection
With the Luminous Pro range of UPS systems, you get an advanced solution Waveform on Battery Mode
Sine Wave
Mains Mode :
that never stops during power cuts! It's Restoration the perfectVoltage solution for you Lower Cut Off Voltage/
100 V AC / 115 V AC
-(UnRegulated UPS Mode )
if you’re running electronic appliances, medical Upper Cut Off Voltage /sensitive Restorationmachinery, Voltage
140 V AC / 150 V AC
285 V AC / 270 V AC
-( UnRegulated UPS Mode )
Lower Cut Off Voltage/ Restoration Voltage equipment, or have heavy power requirements. Voltage
180 V AC / 185 V AC
Upper Cut Off Voltage/ Restoration Voltage -( Regulated UPS Mode )
260 V AC / 255 V AC
(Regulated UPS Mode)
On Battery : On Battery No Load & at Nominal Battery Voltage
Output
220V +/- 2%
Mains Mode:
Rated Power
Apparent Power
Bulb Load (Max)
Frequency Efficiency THD Change Over Time DC Start
2500VA @ 230V
1680 Watts
2100 Watts
3500VA @ 230V
5200VA @ 230V
WORK NEVER STOPS DURING POWER CUTS <= 5%
< 20 ms ; 10ms Typical < 20 ms ; 10ms Typical Yes
Retransfer Time ( UPS to Mains Mode) Cold Start Charger Current
Charging Time Battery Capacity Type of Battery
4000 Watts
> 85% Typical
Transfer Time (Mains to UPS Mode)
Charging Profile
3360 Watts
50 Hz +/- 0.5Hz
On Batt Mode ( at Nominal Load & Nominal Battery Input) THD % (on Battery, Linear/Resistive Load)
No. of Batteries
2940 Watts
40 to 60 Hz
Frequency ( on Mains Mode) Frequency ( on Batt Mode)
Battery System ( Nominal Voltage)
Charger
2000VA @ 230V
On Battery :
H E A V Y
D U T Y
14A/17A/21A
24 V DC
36 V DC
2
3
U S A G E
48 V DC heavy loads Capable of running extremely 4 on a 3 Phase Power supply
Adaptive Battery Charging System 10 -12 hrs Typical 120Ah-240Ah Flat/Tubular or Tubular/VRLA
On/Off Switch on Front Panel
Yes
By Pass Switch External
Yes
72 V DC 6
+
Range: 10 – 100 KVA