Preview only show first 10 pages with watermark. For full document please download

Css150 Series 3 X 5” 150w Ac-dc Medical Power Supplies Features

   EMBED


Share

Transcript

CSS150 Series 3 x 5” 150W AC-DC Medical Power Supplies Features  Wide Range AC Input  Low profile, Industry Standard Footprint  Global Safety Agency Compliance  Dual input fuses Key Market Segments & Applications Specifications Model Input Voltage range Inrush Current Input Current (115/230VAC) Power Factor Correction Leakage Current Hold Up Time (Typ) Temperature Coefficient Voltage Accuracy Minimum Load Total Regulation Ripple & Noise Overcurrent Protection Overvoltage Protection Remote On/Off Efficiency Off load power draw Operating Temperature Storage Temperature Humidity (non condensing) Cooling Withstand Voltage V A A μA ms % A % % V % W °C °C - Isolation Resistance Vibration (non operating) Shock Safety Agency Approvals Conducted & Radiated EMI Immunity MTBF Weight (Typ) Size (WxLxH) Warranty g mm yrs CSS150 90 - 264VAC (47 - 400Hz)(1) or 120 - 180VDC* <60A maximum at 264VAC input, 25°C ambient cold start 1.7 / 0.85 Meets EN61000-3-2, >0.9 <250μA 264VAC 63Hz 16ms at 115VAC input ±0.05%/°C ±1% None ±3% 2% peak to peak 110 - 150% 110 - 150% of nominal (Cycle input power to reset) Unit on: Floating or low <1.2V, Unit off: Apply 5V with respect to 0V 89% typical <0.5W 0 to +70°C derate linearly to 50% load from 50 to 70°C -20 to +85°C 10 - 95% RH Convection or forced air (2.5m/s) Input to Ground 1.5kVAC, Input to Output 3kVAC (2 x MOOPs 3rd Edition), Output to Ground 500VDC for 1 min. >100M at 25C & 70%RH, Output to Ground 500VDC 19.6m/s2 (10~55Hz:2G Constant, X,Y,Z 60min each.) < 196.1 m/s2 (20G) UL/CSA/IEC/EN 60950-1, UL/CSA/IEC/EN 60601-1, ANSI/AAMI ES60601-1, CE Mark EN55011-B, FCC Class B EN60601-1-2 180,000 (MIL-217F-HDBK) 340g 3 x 5 x 1.3” (including underside components) Two Years *Safety certified for AC input only (1) Derate linearly to 90W convection rating from 90 to 100VAC input. 1-800-526-2324 • www.us.tdk-lambda.com/lp/ 95 Disclaimer: us.tdk-lambda.com/lp/legal.htm CSS150 Series Outline Drawing Model Selector Model CSS150-12 CSS150-15 CSS150-24 CSS150-36 CSS150-48 Output Voltage (V) 12V 15V 24V 36V 48V Maximum Current Convection (A) 8.3A 6.7A 4.2A 2.8A 2.1A Connectors (not supplied)  Input Connector mates with Molex Housing 09-50-3031 or equivalent  Output Connector mates with Molex Housing 09-50-3061 or equivalent  Remote On/Off (CN2) mates with J.S.T. XHP-2 1-800-526-2324 • www.us.tdk-lambda.com/lp/ Maximum Power Convection (W) 100W 100W 100W 100W 100W Maximum Current Forced Air 12.5A 10A 6.3A 4.2A 3.1A Maximum Power Forced Air 150W 150W 150W 150W 150W Other Medical Products KM CSS NV175 NV300 15 - 40W pcb mount medical 40 - 500W medical 175 - 200W 1-4 outputs 300W 1-4 outputs For Additional Information, please visit us.tdk-lambda.com/lp/products/css-series.htm 96 Revision A9.1: Oct 2014