Preview only show first 10 pages with watermark. For full document please download

Ct Series-general Purpose

   EMBED


Share

Transcript

CT SERIES-General Purpose CT40-12L (12V40AH) Specification 12V Nominal Voltage Nominal Capacity(10HR) 38.0AH Dimension Length Width Container Height Total Height (with Terminal) 197 165 170 170 2mm (7.76 inches) 2mm (6.50 inches) 2mm (6.69 inches) 2mm (6.69 inches) Approx 13.2 Kg (29.1Ibs) Approx Weight Terminal T6 Container Material ABS Rated Capacity 40.6 AH/2.03A 38.0 AH/3.80A 33.1 AH/6.61A 29.6 AH/9.88A 23.6 AH/23.6A Max. Discharge Current 456A (5s) Emergency light Internal Resistance Approx 10.0mÙ Railway signal and aircraft signal system Operating Temp.Range Discharge : -15 50 0C (5 122 0F) Charge : 0 40 0C (32 104 0F ) Storage : -15 40 0C (5 104 0F) Nominal Operating Temp. Range 25 Cycle Use Initial Charging Current less than12.0A.Voltage 14.4V~15.0V at 25 0 C(77 0 F)Temp. Coefficient -30mV/ 0C (20hr ,1.80V/cell,250C/77 0F) (10hr,1.80V/cell,250C/77 0F) (5hr,1.75V/cell,250C/77 0F) (3hr,1.75V/cell,250C/77 0F) (1hr,1.60V/cell,250C/77 0F) Applications UPS and EPS Marine and power stations Alarm and security system 3 0C (77 5 0F ) Electronic apparatus and Standby Use No limit on Initial Charging Current Voltage 13.5V~13.8V at 25 0 C(77 0 F)Temp. Coefficient -20mV/ 0C Capacity affected by Temperature 40 o C (104 o F) 25 oC ( 77 o F) 0 oC ( 32 o F) Self Discharge CT series batteries may be stored for up to 6 months at 25 0 C(77 0F) and then a freshening charge is required. For higher temperatures the time interval will be shorter. equipment Communication power supply, DC power supply 103% 100% 86% VdS t est ed 9 0 Germany 0 Constant Current Discharge (Amperes) at 25 C (77 F ) F.V/Time 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 44.5 37.4 33.2 27.5 21.2 18.2 11.8 8.84 7.24 6.09 5.34 4.28 3.68 1.96 1.80V/cell 50.9 42.0 36.7 29.9 22.9 19.2 12.6 9.5 7.70 6.46 5.66 4.51 3.80 2.03 1.75V/cell 57.8 47.3 40.5 32.5 25.0 20.9 13.1 9.9 7.97 6.61 5.83 4.66 3.90 2.08 1.70V/cell 65.3 52.5 44.7 35.5 26.9 22.1 13.9 10.4 8.32 6.99 6.11 4.85 4.05 2.14 1.65V/cell 70.1 56.2 47.6 37.4 28.5 22.9 14.4 10.8 8.65 7.21 6.33 5.02 4.17 2.20 1.60V/cell 77.1 61.6 51.7 39.9 29.6 23.6 14.7 11.1 8.84 7.39 6.46 5.11 4.25 2.24 0 0 Constant Power Discharge (Watts/cell) at 25 C (77 F ) F.V/Time 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 83.0 70.5 63.2 53.0 41.2 35.4 23.1 17.4 14.3 12.1 10.6 8.54 7.36 3.93 1.80V/cell 93.9 78.1 68.9 56.7 44.1 37.2 24.6 18.6 15.1 12.7 11.2 8.96 7.58 4.06 1.75V/cell 104.9 87.0 75.4 61.1 47.7 40.3 25.5 19.3 15.6 13.0 11.5 9.24 7.78 4.16 1.70V/cell 115.9 95.2 82.6 66.3 51.2 42.5 26.8 20.2 16.3 13.7 12.0 9.6 8.07 4.26 1.65V/cell 123.3 101.1 87.2 69.4 53.7 43.7 27.7 21.0 16.8 14.1 12.4 9.9 8.29 4.39 1.60V/cell 132.6 109.0 93.7 73.6 55.5 44.8 28.2 21.4 17.2 14.4 12.6 10.1 8.45 4.45 1 Dimensions T6 Terminal Unit: mm [inches] 16 [0.63] 165 2 143 2 2 6 [0.236] M6 [0.236] 170 L 158 2 197 2 Discharge Characteristics Float Charging Characteristics 6V 12V 2V Battery Battery Battery V V V Charged Charged Volume Current Temperature:25 0C % Charge Voltage XCA V 0 Terminal Voltage(V) 0.1CA-2.25V/cell temperature25C 2.16 6.50 13.0 2.00 6.00 12.0 1.84 5.50 11.0 140 120 0.10 10.0 4.50 14.0 80 1.073C 1.52 CHARGE VOLTAGE 2.33 0.263C 5.00 15.0 0.08 0.1C 0.0535C 1.68 CHARGED VOLUME 2.50 100 0.06 0.62C 9.00 13.0 2.16 60 0.04 1.36 4.00 8.00 1 2 4 8 10 6 20 40 0.2 0.3 0.4 0.5 0.1 60 100 1 2 400 600 200 3 4 5 1000 2000 10 20 20 Discharge Time 120 0 CHARGING CURRENT 4 12 8 16 20 24 16 12 10 8 Life expectancy(year) 0.1CA 0.25CA 0.6CA 80 0 28 31 11.0 36 Effect of Temperature on Long Term Float Life Temperature Effects in Relation to Battery Capacity Capacity % 1.83 0 0 12.0 AFTER 100% DISCHARGE 0.02 Min (Hours) 100 AFTER 50% DISCHARGE 2.00 40 2.4C 3.5C 60 40 Charging voltage 2.25V/cell 6 4 1 20 0 -20 0 -10 10 20 30 40 50 60 0 Temperature( C) Remaining Capacity(%) 100C A 0 25 C 60 B 0 40 30 C 10 8 Storage Time(Months) 6 C F O No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.) 1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 3.Charged for 8~10hours at limted current 0.05CA . C 0 4 0 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell. C 20 2 50 122 Supplementary charge required before use.Optional charging way as below: B 0 40 104 Self Discharge Characteristics A 80 0 30 86 Battery temperature 100 40 C 20 68 12 Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached. Sales Office Denmark Sweden Finland and Baltic countries Cell tech AB, Cell tech Oy Cell t ech A/S Aggelundavagen 2,175 62 Jarfalla , Sweden Hoylaamotie 11A , 00380 Helsinki,Finland Rugmarken 9B,3520 Farum,Denmark TEL: +46 8445 7870 TEL: +358 (0)207 999 640 TEL: +45 7025 2201 FAX: +46 8445 7878 FAX: +358 (0)207 999 641 FAX: +45 7025 2202 E-mail:[email protected] E-mail:info@ celltech .fi E-mail:[email protected] www.celltech.se www.celltech .fi www.celltech.dk 2