Preview only show first 10 pages with watermark. For full document please download

Ct Series-general Purpose

   EMBED


Share

Transcript

CT SERIES-General Purpose 460-6125 CT100-12 (12V100AH) Specification Nominal Voltage 12V Nominal Capacity(10HR) 100.0AH Dimensions 330 3mm (12.99 inches) Length 173 2mm (6.81 inches) Width 212 3mm (8.35 inches) Container Height Total Height (with Terminal) 220 3mm (8.66 inches) Approx Weight Terminal Approx 30.4 kg (67.0lbs) Container Material ABS Rated Capacity 104.0 AH/5.20A 100.0 AH/10.0A 86.0 AH/17.2A 78.0 AH/26.0A 61.0 AH/61.0A T6/T11 Max. Discharge Current 1200A (5s) Internal Resistance Approx 4.9mÙ (20hr ,1.80V/cell,250C/770F) (10hr,1.80V/cell,250C/770F) (5hr,1.75V/cell,250C/770F) (3hr,1.75V/cell,250C/770F) (1hr,1.60V/cell,250C/770F) Applications All purpose Uninterruptable Power Supply (UPS) Electric Power System (EPS) Emergency backup power supply 0 Emergency light 0 Operating Temp.Range Discharge : -15 50 C (5 122 F) Charge : 0 400C (32 1040F) Storage : -15 400C (5 1040F) Nominal Operating Temp. Range 25 Railway signal Aircraft signal 30C (77 50F ) Alarm and security system Initial Charging Current less than 30.0A.Voltage Cycle Use Electronic apparatus and equipment 14.4V~15.0V at 250 C(770 F)Temp. Coefficient -30mV/0C Standby Use Communication power supply No limit on Initial Charging Current Voltage DC power supply 13.5V~13.8V at 250 C(770 F)Temp. Coefficient -20mV/0C Auto control system 40o C (104o F) 103% 100% 25o C ( 77o F) 86% 0o C ( 32o F) CT series batteries may be stored for up to 6 months at 250 C(770F) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Capacity affected by Temperature Self Discharge VdS t est ed 9 0 0 Germany Constant Current Discharge (Amperes) at 25 C (77 F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 171.2 134.6 114.4 95.7 76.1 57.6 47.1 30.0 23.7 19.4 15.6 13.6 11.0 9.44 5.15 1.80V/cell 229.7 171.9 138.3 113.1 89.8 67.0 52.8 32.8 25.6 20.7 16.8 14.6 11.7 10.0 5.20 1.75V/cell 259.0 188.9 151.0 121.7 93.2 69.5 55.3 34.0 26.0 21.2 17.2 15.0 11.9 10.1 5.25 1.70V/cell 285.2 205.9 161.2 127.9 97.0 72.3 57.0 35.3 26.8 21.7 17.7 15.3 12.1 10.2 5.35 1.65V/cell 314.5 222.2 171.4 135.9 102.3 74.1 58.9 36.3 27.9 22.5 18.1 15.6 12.3 10.4 5.42 28.7 23.2 18.7 16.0 12.4 10.5 5.45 1.60V/cell 346.9 241.3 183.4 144.8 108.0 77.2 61.0 37.6 Constant Power Discharge (Watts) at 25 0C (77 0F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 312.9 248.6 213.5 180.4 145.0 110.7 90.9 58.3 46.3 37.9 30.6 26.8 21.8 18.7 10.2 1.80V/cell 415.6 313.9 254.5 210.1 168.5 127.7 101.3 63.2 49.5 40.3 32.8 28.6 23.1 19.8 10.3 1.75V/cell 458.6 339.3 274.6 223.9 173.5 131.3 105.5 65.3 50.2 41.0 33.5 29.3 23.4 19.9 10.4 1.70V/cell 491.0 361.5 289.1 233.5 179.5 136.0 108.5 67.8 51.5 42.0 34.3 29.8 23.7 20.1 10.6 1.65V/cell 533.7 386.5 305.0 246.2 187.8 138.1 111.3 69.3 53.5 43.3 35.1 30.4 24.0 20.5 10.7 1.60V/cell 575.1 410.1 320.8 259.4 196.9 143.2 114.7 71.2 54.9 44.5 36.2 31.0 24.2 20.7 10.8 1 Dimensions T11 Terminal Unit: mm [inches] 20 [0.787] 173 2 220 2 212 2 6 [0.236] M8 [0.315] 330 Discharge Characteristics 12V Battery V Float Charging Characteristics 0 Temperature:25 0 C(77F) Charging Charging Current Voltage Charge Volume 13.0 12.0 0 0.10CA-2.25V/cell (V) (XCA) % Terminal Voltage(V) 2 temperature25 C 0.25 120 110 11.0 0.4C 10.0 1C 9.0 0.205C 100 0.1C 0.0525C 90 80 15.0 14.0 50 Charge Voltage (Constant 2.25v/cell) 0.15 13.0 70 60 0.6C Charged Volume 0.20 0.10 After 50% Discharge 12.0 40 8.0 30 2C 1 2 4 6 8 10 20 40 2 60 6 8 10 4 20 10 0 20 H Min After 100% Discharge 0.05 11.0 Charging Current 0 0 4 8 16 12 20 32 28 24 36 40 Discharge Time Charging Time(hours) Temperature Effects in Relation to Battery Capacity Effect of Temperature on Long Term Float Life 120 10 6 5 4 0.25CA 80 Life expectancy(year) % 100 Capacity 8 0.1CA 0.17CA 60 40 Charging voltage : 2.25V/cell 3 2 1 20 0.5 -20 0 -10 10 20 30 40 50 30 86 20 68 60 Temperature( C) Testing condition Discharging:current 0.17C (FV 1.7V/cell); Charging:current 0.25C max, voltage 2.45V/cell; Charging volume:125% of discharged capacity. Remaining Capacity(%) Capcity(%) 80 60 50% DOD 400 600 800 1000 A 250C B 60 300C 400C 40 C 20 0 30% DOD 2 4 6 8 10 12 Storage Time(Months) Ambient Termperature: 25oC (77oF) 200 100C 80 100 0 0 C F O 100 120 20 0 Self Discharge Characteristics Cycle Life in Relation to Depth of Discharge 100% DOD 50 122 Battery temperature 0 40 40 104 A No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.) B Supplementary charge required before use.Optional charging way as below: 1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell. 3.Charged for 8~10hours at limted current 0.05CA . C Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached. 1200 Number of Cycles Sales Office Denmark Sweden Finland and Baltic countries Cell tech AB, Cell tech Oy Cell t ech A/S Aggelundavagen 2,175 62 Jarfalla , Sweden Hoylaamotie 11A , 00380 Helsinki,Finland Rugmarken 9B,3520 Farum,Denmark TEL: +46 8445 7870 TEL: +358 (0)207 999 640 TEL: +45 7025 2201 FAX: +46 8445 7878 FAX: +358 (0)207 999 641 FAX: +45 7025 2202 E-mail:[email protected] E-mail:info@ celltech .fi E-mail:[email protected] www.celltech.se www.celltech .fi www.celltech.dk 2