Transcript
Cloud Storage Gateway Specifications
CTERA CLOUD STORAGE GATEWAYS SPEC SHEET CTERA Cloud Storage Gateways are the all-in-one solution for modernizing storage, backup and file sharing across dispersed enterprises. The appliances are easy to deploy, manage and use, and replace file servers, tape backup and other proprietary systems with a single, DEPLOY AND MANAGE TURNKEY CLOUD STORAGE SOLUTIONS cloud-integrated and cost-effective solution.
C200
C400
C800
C800+
EV16
Appliance Configurations Form Factor
CTERA Hardware Appliance
CTERA Hardware Appliance
CTERA Hardware Appliance
CTERA Hardware Appliance
CTERA Virtual Appliance*
Up to 8TB
Up to 16TB
Up to 32TB
Up to 32TB
Up to 16TB**
Up to 50
Up to 100
Up to 200
Up to 1,000
Up to 250**
2 x 3.5"
4 x 3.5"
8 x 3.5"
8 x 3.5"
not applicable
1.1 Kg
7.2 Kg
12.5 Kg
12.5 Kg
not applicable
162.5(H) x 210(D) x 95(W) mm
44(H) X 446.4(W) X 500(D) mm
88(H) X 446.4(W) X 506(D) mm
88(H) X 446.4(W) X 506(D) mm
6.4(H) x 8.27(D) x 3.74(W) inch
1.73(H) x 17.6(D) x 19.7(D) inch
3.46(H) x 17.6(D) x 19.9(D) inch
3.46(H) x 17.6(D) x 19.9(D) inch
Pedestal
1U
2U
2U
not applicable
1
1
1
2
not applicable
50W
220W
256W
256W
not applicable
Local Appliance Capacity Recommended Number of Users Drive Bays Weight (without hard drives)
Dimensions
Rack Height Power Supply Max. Power Consumption
0-40°C, Humidity 5%-90% (non-condensed)
Operating Environment USB 2.0 Ports Ethernet
not applicable
not applicable
2
4
2
2
not applicable
1 x 1Gb
2 x 1Gb
2 x 1Gb
2 x 1Gb
Up to 10Gb
FCC, CE, RoHS, WEEE
Compliance
* CTERA EV16 requires at minimum: 2 x vCPUs, 2GB RAM, 1TB storage. Recommended configuration: 4 x vCPUs, 8GB RAM, 16TB storage. ** EV virtual gateways are also available in larger configurations up to 64TB. Contact CTERA for more details.
www.ctera.com
[email protected]
USA: (650) 227-4950
Intl.: +972-3-679-9000
©2016 CTERA Networks Ltd., All Rights Reserved
Cloud Storage Gateway Specifications
C200
C400
C800
C800+
EV16
Appliance Software Features Max. CIFS Connections
50
200
400
1,500
500
Pre-Bundled Workstation Backup Agents
20
50
50
50
0
Max. Workstation Backup Agents
20
50
100
200
125
Pre-Bundled Server Backup Agents
1
2
2
2
0
Max. Server Backup Agents
2
5
10
20
15
EXT3, NEXT3™
Supported File Systems
EXT3, NEXT3™, XFS
Supported Discovery Protocols
UPnP, Bonjour
File Access Protocols
CIFS/SMB, NFS, AFP, FTP, WebDAV, rsync, iSCSI, CTERA Mobile, CTERA Sync desktop application, web browser Selective file tiering from cloud, user and administrator-defined file sync and share across offices and endpoint devices. Flexible, configrable retention of thin snapshots across appliance and cloud
File Management
Microsoft Exchange, SQL Server, SharePoint, Hyper-V and Active Directory
Application-Aware Backup
Supports Windows ACLs, quotas, Windows Server data and permission migration tools
Permission Management RAID Levels S.M.A.R.T. HDD Monitoring
0/1, JBOD
0/1/5/6, JBOD
0/1/5/6, JBOD
0/1/5/6, JBOD
JBOD
Yes
Yes
Yes
Yes
not applicable
Remote access, management and monitoring, firmware upgrades
Appliance Management not applicable
Supported Hypervisors
not applicable
not applicable
not applicable
KVM, VMware
Active Directory
User Authentication
AES-256 at-rest encryption
Data Security
(Read-only) Broadcast of 3rd party software firmware updates across sites, PXE boot services, wake on LAN
Office Software Updates
Cloud Service Features Retention
Unlimited retention of previous file versions and snapshots
File Sync
Centralized file management, user and admin-level file replication and tiering policies Source-based AES-256 encryption, SHA-1 fingerprints, optional secret passphrase
Backup Files Security
TLS (Transport Level Security)
Protocol Security
Incremental-forever appliance backups, data compression, global deduplication with variable block size optimization, bandwidth throttling
Efficiency
Centralized monitoring, reporting, logging, remote access, configuration change, firmware updates
Centralized Management Cloud Seeding
Ship and upload first backups to cloud provider for physical transport and fast upload of appliance data to the cloud
Cloud Failover
Failover synced files and folders to CTERA remotely mounted Cloud Drive, <5 minute user access recovery
www.ctera.com
[email protected]
USA: (650) 227-4950
Intl.: +972-3-679-9000
©2016 CTERA Networks Ltd., All Rights Reserved