Transcript
CU 5502 4P flex _ Flexible data cable, S/UTP, Category 5e, AWG26, Euroclass Eca
1 Inner conductor: AWG26, bare copper wire, stranded 2 PE insulated conductor: Ø 0.98 mm 3 Polyester foil 4 Overall screen: tinned braided copper 5 Outer sheath: FR/PVC, various colours
DESCRIPTION Electrically and mechanically superior quality Cat.5e patch cord - exceeds the requirements of ISO/IEC 11801, IEC 61156-6, EN 50173-1 and EN 50288-2-2. Construction optimised for fast and reliable terminations. Easy wire identification and termination due to different coloured wires. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801. Optimised for RJ45 connecting systems. Differently coloured sheaths facilitate clearly arranged installations and visual differentiation of services.
APPLICATION As patch cord in patch panels and as equipment connection cable. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class D applications (100 MHz) in accordance with EN 50173-1 and ISO/IEC 11801. Applicable for Power over Ethernet (PoE) / PoE+.
ELECTRICAL CHARACTERISTICS Category Frequency [MHz] Attenuation [dB/10m] NEXT [dB] PS NEXT [dB] ACR-N [dB/10m] PS-ACR-N [dB/10m] ACR-F [dB/10m] PS-ACR-F [dB/10m] Return loss [dB] These performance data are typical measured values.
As of 18.09.2017
1 0.2 75 72 74 71 80 77 24
4 0.5 70 67 69 66 78 75 30
10 0.8 65 62 64 61 75 72 30
5e 100 3.0 42 39 39 36 60 57 28
250 5.2 35 32 30 27 53 50 23
300 5.8 33 30 27 24 50 47 23
Subject to technical modification.
CU 5502 4P flex _ Flexible data cable, S/UTP, Category 5e, AWG26, Euroclass Eca
ELECTRICAL PROPERTIES
220 Ω/km 45 pF/m 100 Ω ±5 Ω 20/9/25 mΩ/m > 55 dB
Loop resistance at 20° C: Mutual capacitance: Impedance at 100 MHz: Transfer impedance at 1/10/30 MHz: Coupling attenuation (limit curve of critical state - IEC 61156): Near end unbalance attenuation LCL at 1-100 MHz : Delay Skew: NVP:
> 40 dB 15 ns/100 m 75 %
MECHANICAL PROPERTIES Bending radius: Repeated bending: Tensile strength: Crush resistance: Impact: Temperature range
≥ 20 mm ≥ 1000 cycles ≤ 63 N ≥ 1000 N/10 cm ≥ 10 impacts 0° C to + 50° C -20° C to + 60° C
during installation: in operation:
STANDARDS Wire colour Imprint Flame propagation Reaction to fire (Euroclasses)
white /blue red/orange black/green yellow/brown in accordance with IEC 60189 and IEC 60708 DATWYLER «cable type» «additional text» «batch number» «meter marks» IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1 EN 13501-6: Eca
PoE EMC Segregation class Cat./Class
IEEE 802.3af shielded c Cat 5e / Class D - limit values as specified by IEC 61156-6 and EN 50288-2-2 guaranteed
VERSIONS Article Number
DoP Product
Sheath Sheath Ø [mm]
Sheath colour
Weight [kg/km]
Cu rate [kg/km]
Fire load [MJ/m]
Fire load [kWh/m]
Dimensions n x p x [mm² (AWG)]
PU
179595
CU 5502 4P FR/PVC 5.1 flex
grey
34
23.5
0.38
0.11
4 x 2 x 0.16 (AWG26)
1000 m drum
179517
CU 5502 4P FR/PVC 5.1 flex
black
34
23.5
0.38
0.11
4 x 2 x 0.16 (AWG26)
1000 m drum
179513
CU 5502 4P FR/PVC 5.1 flex
green
34
23.5
0.38
0.11
4 x 2 x 0.16 (AWG26)
1000 m drum
As of 18.09.2017
Subject to technical modification.
CU 5502 4P flex _ Flexible data cable, S/UTP, Category 5e, AWG26, Euroclass Eca
179514
CU 5502 4P FR/PVC 5.1 flex
yellow
34
23.5
0.38
0.11
4 x 2 x 0.16 (AWG26)
1000 m drum
179515
CU 5502 4P FR/PVC 5.1 flex
red
34
23.5
0.38
0.11
4 x 2 x 0.16 (AWG26)
1000 m drum
179516
CU 5502 4P FR/PVC 5.1 flex
blue
34
23.5
0.38
0.11
4 x 2 x 0.16 (AWG26)
1000 m drum
As of 18.09.2017
Subject to technical modification.