CU 5502 4P flex _ Flexible data cable, S/UTP, Category 5e, AWG26, Euroclass Eca 1 Inner conductor: AWG26, bare copper wire, stranded 2 PE insulated conductor: Ø 0.98 mm 3 Polyester foil 4 Overall screen: tinned braided copper 5 Outer sheath: FR/PVC, various colours DESCRIPTION Electrically and mechanically superior quality Cat.5e patch cord - exceeds the requirements of ISO/IEC 11801, IEC 61156-6, EN 50173-1 and EN 50288-2-2. Construction optimised for fast and reliable terminations. Easy wire identification and termination due to different coloured wires. Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801. Optimised for RJ45 connecting systems. Differently coloured sheaths facilitate clearly arranged installations and visual differentiation of services. APPLICATION As patch cord in patch panels and as equipment connection cable. For the transmission of digital and analogue voice, video and data signals. Suitable for all ICT network applications up to class D applications (100 MHz) in accordance with EN 50173-1 and ISO/IEC 11801. Applicable for Power over Ethernet (PoE) / PoE+. ELECTRICAL CHARACTERISTICS Category Frequency [MHz] Attenuation [dB/10m] NEXT [dB] PS NEXT [dB] ACR-N [dB/10m] PS-ACR-N [dB/10m] ACR-F [dB/10m] PS-ACR-F [dB/10m] Return loss [dB] These performance data are typical measured values. As of 18.09.2017 1 0.2 75 72 74 71 80 77 24 4 0.5 70 67 69 66 78 75 30 10 0.8 65 62 64 61 75 72 30 5e 100 3.0 42 39 39 36 60 57 28 250 5.2 35 32 30 27 53 50 23 300 5.8 33 30 27 24 50 47 23 Subject to technical modification. CU 5502 4P flex _ Flexible data cable, S/UTP, Category 5e, AWG26, Euroclass Eca ELECTRICAL PROPERTIES 220 Ω/km 45 pF/m 100 Ω ±5 Ω 20/9/25 mΩ/m > 55 dB Loop resistance at 20° C: Mutual capacitance: Impedance at 100 MHz: Transfer impedance at 1/10/30 MHz: Coupling attenuation (limit curve of critical state - IEC 61156): Near end unbalance attenuation LCL at 1-100 MHz : Delay Skew: NVP: > 40 dB 15 ns/100 m 75 % MECHANICAL PROPERTIES Bending radius: Repeated bending: Tensile strength: Crush resistance: Impact: Temperature range ≥ 20 mm ≥ 1000 cycles ≤ 63 N ≥ 1000 N/10 cm ≥ 10 impacts 0° C to + 50° C -20° C to + 60° C during installation: in operation: STANDARDS Wire colour Imprint Flame propagation Reaction to fire (Euroclasses) white /blue red/orange black/green yellow/brown in accordance with IEC 60189 and IEC 60708 DATWYLER «cable type» «additional text» «batch number» «meter marks» IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1 EN 13501-6: Eca PoE EMC Segregation class Cat./Class IEEE 802.3af shielded c Cat 5e / Class D - limit values as specified by IEC 61156-6 and EN 50288-2-2 guaranteed VERSIONS Article Number DoP Product Sheath Sheath Ø [mm] Sheath colour Weight [kg/km] Cu rate [kg/km] Fire load [MJ/m] Fire load [kWh/m] Dimensions n x p x [mm² (AWG)] PU 179595 CU 5502 4P FR/PVC 5.1 flex grey 34 23.5 0.38 0.11 4 x 2 x 0.16 (AWG26) 1000 m drum 179517 CU 5502 4P FR/PVC 5.1 flex black 34 23.5 0.38 0.11 4 x 2 x 0.16 (AWG26) 1000 m drum 179513 CU 5502 4P FR/PVC 5.1 flex green 34 23.5 0.38 0.11 4 x 2 x 0.16 (AWG26) 1000 m drum As of 18.09.2017 Subject to technical modification. CU 5502 4P flex _ Flexible data cable, S/UTP, Category 5e, AWG26, Euroclass Eca 179514 CU 5502 4P FR/PVC 5.1 flex yellow 34 23.5 0.38 0.11 4 x 2 x 0.16 (AWG26) 1000 m drum 179515 CU 5502 4P FR/PVC 5.1 flex red 34 23.5 0.38 0.11 4 x 2 x 0.16 (AWG26) 1000 m drum 179516 CU 5502 4P FR/PVC 5.1 flex blue 34 23.5 0.38 0.11 4 x 2 x 0.16 (AWG26) 1000 m drum As of 18.09.2017 Subject to technical modification.